Search Results

Search found 62759 results on 2511 pages for 'view first'.

Page 460/2511 | < Previous Page | 456 457 458 459 460 461 462 463 464 465 466 467  | Next Page >

  • install Win7 SP1 with bcdedit failing

    - by Albert
    I'm getting the error 0x800F0A12 which is described here. bcdedit says: C:\>bcdedit.exe Der Speicher für die Startkonfigurationsdaten konnte nicht geöffnet werden. Das System kann die angegebene Datei nicht finden. (English: Couldn't open the start configuration. Couldn't find the file.) (off topic: how can I get those messages in English?) I played around and I assume that is because the system partition C:\ is not on the first BIOS disk. There are 4 disks in my PC. On one of them (shown as the 4th in Windows drive manager) contains Windows, whereby the system-reserved NTFS partition is the first primary and the second primary is my main Windows system partition. A few more partitions follow with other (non-NTFS) stuff. I was able to set the first two disks offline (via the Windows drive manager). For the 3rd disk, it says that it cannot set the BIOS 0 disk offline. How can I ignore that and still install SP1? I don't want to rewire/resetup my disks.

    Read the article

  • Reduce power consumption of gaming computer while idle

    - by White Phoenix
    This is my current build: EVGA X58 (first generation) motherboard Intel i7 965 clocked @ 3.3 Ghz 3x DDR3-1600 Corsair RAM at stock timings and voltages Corsair AX750 80 Plus Gold PSU 1 Optical Drive 1 Seagate 7200.10 500 GB drive 2x Western Digital Caviar Black 1 TB drives OCZ Vertex 1 60 GB EVGA GTX 460 oc'd at 800/1600/1850 Antec 1200 case HT-Omega Striker 7.1 Sound Card Windows 7 32-bit Professional (PAE Enabled) I've already seen this post Reduce power use on computer and this post How do I lower power consumption of my computer and while useful, I'm looking for answers specific to my build and OS. I'm pretty sure this build is a energy-intensive build by default, but I want to try to reduce the amount of energy my build uses when I leave it idle (when I go to bed or go out, etc). The first requirement for this machine is that I need to leave it on, so I cannot turn it off while it's being unused. I run it as a file server for personal reasons and I also leave it on in case people leave me messages on various IM services and chat clients (IRC, MSN, Steam, XFire, Pidgin, etc). I'm also unable to replace the parts in my computer with a cheaper "greener" part. What are some ways to minimize the amount of power the machine uses? I'm already using a high efficiency power supply (80 Plus Gold), but I imagine there's other things that can be done in the BIOS and Windows' power settings to reduce power usage while I'm not using the computer. From what I can tell, I can't use Sleep since that'll disable network access (whole reason why I leave the computer on in the first place). I already turn off my monitor when it's not in use. I enabled Intel SpeedStep within the BIOS (I know, I have a 965 and why am I enabling SpeedStep?) Should I bring the graphics card back to stock speeds and lower the clock on the processor even more? Main reason why I'm asking is I think this computer alone is the reason why my power bill is high, so I want to reduce its consumption to as low as possible without having to shut the thing down.

    Read the article

  • Network bridge does not work on Windows 7

    - by D. Strout
    I am trying to use Windows 7 to bridge my wireless and wired connections together to get wireless on a second Windows XP computer (fresh install). The network bridge is created successfully, but when I connect the cable from the first computer with the bridged connections to the second one with just a wired connection, nothing happens. The second computer doesn't connect, and the first computer shows no sign of anything different. I tried bridging the connections of a third computer, and connecting this computer to the second computer. This worked (third computer bridged the wireless to the second computer). Thus, the problem must be with the first (Win 7) computer. However, I have no idea what the problem could be. All Internet Connection Sharing is turned off. Homegroup is disabled (it was originally enabled, I thought that might be a problem, so I disabled it). Also, I had VMWare fusion installed, and that created extra items in the "This connection uses the following items" box in the properties dialog. Thinking this might be causing issues, I uninstalled that too. Still, with everything I tried, I can't get it to work. Any suggestions? Edit: Another thing I noticed that might be worth mentioning: The network icon in the Win7 taskbar has a red X on it that means it's not connected, but when I click the icon, it says connected next to my wireless connection, and I am able to access the internet.

    Read the article

  • How should I monitor memory usage/performance in SunOS/Solaris?

    - by exhuma
    Last week we decided to add some SunOS (uname -a = SunOS bbs-sam-belair 5.10 Generic_127128-11 i86pc i386 i86pc) machines into our running munin instance. First off, the machines are pre-configured appliances, so, I want to avoid touching the system too much without supervision of the service provider. But adding it to munin was fairly easy by writing a small socket-service (if anyone is interested, I put it up on github: https://github.com/munin-monitoring/contrib/tree/master/tools/pypmmn) Yesterday, I implemented/adapted the required plugins for our machines. And here the questions start: First, I have not found a way to determine detailed memory usage values. I get the total memory by running prtconf | grep Memory, and the free memory using vmstat. Fiddling together a munin-plugin, gives me the following graph: This is pretty much uninformative. Compare this to the default plugin for linux nodes which has a lot more detail: Most importantly, this shows me how much memory is actually used by applications. So, first question: Is it possible to get detailed memory information on SunOS with the default system tools (i.e. not using top)? Onto the next puzzle: Seeing the graphs, I noticed activity in the "Paging in/out" graphs, even though the memory graph still has unused memory: Upon further investigation, I found out that df reports that /tmp is mounted on swap. Drilling around on the web, I understood that df will display swap, but in fact, it's mounted as a tmpfs. Now I don't know if this explains the swap activity. The default munin-plugin for solaris uses kstat -p -c misc -m cpu_stat to get these values. I find it already strange that this is using the cpu_stat module. So maybe I simply misinterpret the "paging" graphs? Second question: Do the paging graphs indicate that parts of the memory are paged to disk? Or is the activity caused by file operations in /tmp?

    Read the article

  • nginx 2 symfony2 web application, one ip no domain

    - by Krzysztof Koch
    I have irritating with nginx. I set up in /usr/share/nginx/www/firstapp one application and in /usr/share/nginx/www/secondapp. in my default conf i setup that in / root localization i want first app: when write 9.9.9.9 in browser show me first app, and when i write 9.9.9.9/makeup, there not show me seccond app. Why first app displays me good, and seccondapp cannot? Please help me. Sorry for quality here pasterbin code: enter link description here server { listen 80; server_name localhost; root /usr/share/nginx/www/firstapp/web; access_log /var/log/nginx/$host.access.log; error_log /var/log/nginx/error.log error; # strip app.php/ prefix if it is present rewrite ^/app\.php/?(.*)$ /$1 permanent; location / { root /usr/share/nginx/www/firstapp/web/; index app.php; try_files $uri @rewriteapp; } location /makeup/ { alias /usr/share/nginx/www/seccondapp/web/; index app.php; try_files $uri @rewriteapp; } location @rewriteapp { rewrite ^(.*)$ /app.php/$1 last; } # pass the PHP scripts to FastCGI server listening on 127.0.0.1:9000 location ~ ^/(app|app_dev)\.php(/|$) { #fastcgi_pass 127.0.0.1:9000; fastcgi_pass unix:/var/lib/php5-fpm/www.sock; fastcgi_split_path_info ^(.+\.php)(/.*)$; include fastcgi_params; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; fastcgi_param HTTPS off; #fastcgi_param SERVER_PORT 80; }

    Read the article

  • hard drive recognized by bios but not by windows

    - by tehgeekmeister
    I'm adding a new hard drive (A seagate ST31000340NS; I had links in here but I don't have enough reputation to post them. Interestingly, the bios recognizes it as a ST31000340AS, but it was bought as the other number...) to a friend's hp pavilion d4650e (mobo specs; google the model if you want the rest of the info, can't do more than one link.). Have had a hell of a time with it. Finally figured out that the hard drive needed a jumper set to limit the speed to 1.5gbps so the mobo would recognize it, and the bios DOES recognize it now. But not windows (using windows 7), using add new hardware or diskmgmt.msc. According to my friend, who was at the computer when it first booted after adding the jumper, a new hardware found dealio popped up saying something about raid, but I can't provide more info then that since I didn't see it. Ubuntu livecd recognized the drive before we changed the jumper. Haven't checked since then. XP didn't recognize it, that's the OS we started with. Upgraded to 7 hoping it might fix the problem. The only other info I can think of that might be immediately relevant is that the drive is plugged into the fifth sata channel, and the first channel is empty. Is this a problem? I assume not, because the two other drives (in a raid 0) and the cd and dvd drives are also on channels past the first one, and are recognized. Ask questions and I'll update with info!

    Read the article

  • Lenovo S10 Ideapad will not boot while original hard drive is installed, neither from hard drive or

    - by aki
    Hello, first time posting here so I'll try to be very clear. I have a Lenovo S10 Ideapad netbook which fails to boot to an OS. It shows the Lenovo splash screen and can get to the BIOS but it doesn't get to GRUB (was dual booting Ubuntu 9.10 and Win 7, was working fine for months, ie this isn't a new dual boot gone bad). After the splash screen it displays a flashing cursor in the upper left corner. Power cycled to no avail. Here is what I have done trying to narrow the problem down: The machine will boot to Ubuntu using an install/live USB drive, but only if ANOTHER hard drive is installed or NO hard drive is installed. The boot order always lists USB first. Also, there is a 2 gb RAM upgrade but I think that's fine; the Ubuntu USB drive boots fine with it, and "free" sees the whole 2gb of memory. So it seems like the hard drive is bad. I was able to put the bad drive in a different laptop and mount it to recover files. I'm ready to replace the bad hard drive, but I would like to know if this situation makes any sense. If the hard drive is bad, shouldn't I still be able to boot with the Ubuntu USB drive while the bad drive is installed? I would have expected the machine to boot into Ubuntu anyway even if with a bad drive, since the boot order lists USB first. But it seems that when the bad drive is installed, the machine ignores the USB drive and hangs with the flashing cursor. Thanks for any ideas! Sorry for the long post, I just want to put all the info I have up front! Basically I'm going to buy a new drive, but I am mostly curious if this is a typical or at least not unusual situation.

    Read the article

  • publickey authentication only works with existing ssh session

    - by aaron
    publickey authentication only works for me if I've already got one ssh session open. I am trying to log into a host running Ubuntu 10.10 desktop with publickey authentication, and it fails when I first log in: [me@my-laptop:~]$ ssh -vv host ... debug1: Next authentication method: publickey debug1: Offering public key: /Users/me/.ssh/id_rsa ... debug2: we did not send a packet, disable method debug1: Next authentication method: password me@hosts's password: And the /var/log/auth.log output: Jan 16 09:57:11 host sshd[1957]: reverse mapping checking getaddrinfo for cpe-70-114-155-20.austin.res.rr.com [70.114.155.20] failed - POSSIBLE BREAK-IN ATTEMPT! Jan 16 09:57:13 host sshd[1957]: pam_sm_authenticate: Called Jan 16 09:57:13 host sshd[1957]: pam_sm_authenticate: username = [astacy] Jan 16 09:57:13 host sshd[1959]: Passphrase file wrapped Jan 16 09:57:15 host sshd[1959]: Error attempting to add filename encryption key to user session keyring; rc = [1] Jan 16 09:57:15 host sshd[1957]: Accepted password for astacy from 70.114.155.20 port 42481 ssh2 Jan 16 09:57:15 host sshd[1957]: pam_unix(sshd:session): session opened for user astacy by (uid=0) Jan 16 09:57:20 host sudo: astacy : TTY=pts/0 ; PWD=/home/astacy ; USER=root ; COMMAND=/usr/bin/tail -f /var/log/auth.log The strange thing is that once I've got this first login session, I run the exact same ssh command, and publickey authentication works: [me@my-laptop:~]$ ssh -vv host ... debug1: Server accepts key: pkalg ssh-rsa blen 277 ... [me@host:~]$ And the /var/log/auth.log output is: Jan 16 09:59:11 host sshd[2061]: reverse mapping checking getaddrinfo for cpe-70-114-155-20.austin.res.rr.com [70.114.155.20] failed - POSSIBLE BREAK-IN ATTEMPT! Jan 16 09:59:11 host sshd[2061]: Accepted publickey for astacy from 70.114.155.20 port 39982 ssh2 Jan 16 09:59:11 host sshd[2061]: pam_unix(sshd:session): session opened for user astacy by (uid=0) What do I need to do to make publickey authentication work on the first login? NOTE: When I installed Ubuntu 10.10, I checked the 'encrypt home folder' option. I'm wondering if this has something to do with the log message "Error attempting to add filename encryption key to user session keyring"

    Read the article

  • Configuring three monitors with two Radeon X1600/X1650 graphics cards under Ubuntu

    - by cpm
    I have three SyncMaster 932a monitors I want to use with two Radeon X1600/X1650 cards under Linux. I am running X.org X Server 1.6.0, as provided by Ubuntu's Wubi installer. After turning off mirroring, I ended up with this xorg.conf: Section "Monitor" Identifier "Configured Monitor" EndSection Section "Screen" Identifier "Default Screen" Monitor "Configured Monitor" Device "Configured Video Device" SubSection "Display" Virtual 2560 1024 EndSubSection EndSection Section "Device" Identifier "Configured Video Device" EndSection The left monitor had a menu bar and a task bar, the center monitor was just desktop, and windows would maximize to the current monitor. The third monitor and second graphics card weren't being used at all. Then I changed my configuration to manually specify each card with their PCI bus: Section "ServerLayout" Identifier "TheLayout" Screen 0 "Radeon Screen 1" Screen 1 "Radeon Screen 2" RightOf "Radeon Screen 1" EndSection Section "Screen" Identifier "Radeon Screen 1" Monitor "Configured Monitor" Device "Radeon the First" SubSection "Display" Virtual 2560 1024 EndSubSection EndSection Section "Screen" Identifier "Radeon Screen 2" Monitor "Configured Monitor" Device "Radeon the Second" EndSection Section "Device" Identifier "Radeon the First" Driver "radeon" BusID "PCI:1:0:0" EndSection Section "Device" Identifier "Radeon the Second" Driver "radeon" BusID "PCI:2:0:0" EndSection Section "Monitor" Identifier "Configured Monitor" EndSection Now both the left and right monitors have task bars and menu bars. Windows cannot be dragged from the first two monitors to the third monitor. Also, maximizing in the left or center window fills both monitors. I also tried adding Option "Xinerama" "true" to the ServerLayout section. X11 wasn't able to start up. I want to: Allow moving windows along all three monitors. Maximizing only fills the current monitor. Either have menu/task bars on only the left monitor or all three monitors How can I make this possible?

    Read the article

  • PC freezes after repeated clicking noises

    - by Péter Török
    I have an oldish PC (Athlon XP 2200, WinXP). Every time I switch it on, I hear a loud "click" first of all, and when it is shut down, again a click is the last sound I hear. Lately it started to behave erratically: it started to click loudly in the middle of a session. First only once in a while, then repeatedly for several seconds in a row, and finally it froze completely. We were not doing anything particular during these times, usually just browsing the web. This has already happened twice in a few week's time period. We typically use it only in the evenings, so when the freeze happened, I just decided it is time for the bed. When it was started up the next day, everything looked fine. Any hints on what could be the culprit? Could it be caused by an ageing heat fan, or dust that has accumulated inside the case? We are backing up all the data stored on it, and then will open the case to look inside, but I thought it would be good to get some background info first of all.

    Read the article

  • Server unreachable without www

    - by deamon
    My server is unreachable without "www." prefix, even when trying it with ping. The DNS entry looks like this: $TTL 86400 @ IN SOA ns1.first-ns.de. postmaster.robot.first-ns.de. ( 2011010600 ; serial 14400 ; refresh 1800 ; retry 604800 ; expire 86400 ) ; minimum @ IN NS robotns3.second-ns.com. @ IN NS robotns2.second-ns.de. @ IN NS ns1.first-ns.de. @ IN A 1.2.3.4 localhost IN A 127.0.0.1 mail IN A 1.2.3.4 www IN A 1.2.3.4 ftp IN CNAME www imap IN CNAME www loopback IN CNAME localhost pop IN CNAME www relay IN CNAME www smtp IN CNAME www @ A DNS record of the same type for another domain on the same server is working with and without "www". And the VirualHost config looks like this: <VirtualHost *:80> ServerName somewhere.com ServerAlias www.somewhere.com ServerSignature Off ... </VirtualHost> Any idea what could be wrong?

    Read the article

  • apache using mod_auth_kerb always asks for the password twice

    - by DrStalker
    (Debian Squeeze) I'm trying to set apache up to use Kerberos authentication to allow AD users to log in. It is working, but prompts the user twice for a username and password, with the first time being ignored (no matter what is put it in.) Only the second prompt includes the AuthName string from the config (i.e.: the first windows is a generic username/password one, the second includes the title "Kerberos Login") I'm not worried about integrated windows authentication working at this stage, I just want users to be able to login with their AD account so we don't need to set up a second repository of user accounts. How do I fix this to eliminate that first useless prompt? The directives in the apache2.conf file: <Directory /var/www/kerberos> AuthType Kerberos AuthName "Kerberos Login" KrbMethodNegotiate On KrbMethodK5Passwd On KrbAuthRealms ONEVUE.COM.AU.LOCAL Krb5KeyTab /etc/krb5.keytab KrbServiceName HTTP/[email protected] require valid-user </Directory> krb5.conf: [libdefaults] default_realm = ONEVUE.COM.AU.LOCAL [realms] ONEVUE.COM.AU.LOCAL = { kdc = SYD01PWDC01.ONEVUE.COM.AU.LOCAL master_kdc = SYD01PWDC01.ONEVUE.COM.AU.LOCAL admin_server = SYD01PWDC01.ONEVUE.COM.AU.LOCAL default_domain = ONEVUE.COM.AU.LOCAL } [login] krb4_convert = true krb4_get_tickets = false The access log when accessing the secured directory (note the two seperate 401's) 192.168.10.115 - - [24/Aug/2012:15:52:01 +1000] "GET /kerberos/ HTTP/1.1" 401 710 "-" "Mozilla/5.0 (Windows NT 6.1; WOW64) AppleWebKit/537.1 (KHTML, like Gecko) Chrome/21.0.1180.83 Safari/537.1" 192.168.10.115 - - [24/Aug/2012:15:52:06 +1000] "GET /kerberos/ HTTP/1.1" 401 680 "-" "Mozilla/5.0 (Windows NT 6.1; WOW64) AppleWebKit/537.1 (KHTML, like Gecko) Chrome/21.0.1180.83 Safari/537.1" 192.168.10.115 - [email protected] [24/Aug/2012:15:52:10 +1000] "GET /kerberos/ HTTP/1.1" 200 375 "-" "Mozilla/5.0 (Windows NT 6.1; WOW64) AppleWebKit/537.1 (KHTML, like Gecko) Chrome/21.0.1180.83 Safari/537.1" And one line in error.log [Fri Aug 24 15:52:06 2012] [error] [client 192.168.0.115] gss_accept_sec_context(2) failed: An unsupported mechanism was requested (, Unknown error)

    Read the article

  • How should I set up protection for the database against sql injection when all the php scripts are flawed?

    - by Tchalvak
    I've inherited a php web app that is very insecure, with a history of sql injection. I can't fix the scripts immediately, I rather need them to be running to have the website running, and there are too many php scripts to deal with from the php end first. I do, however, have full control over the server and the software on the server, including full control over the mysql database and it's users. Let's estimate it at something like 300 scripts overall, 40 semi-private scripts, and 20 private/secure scripts. So my question is how best to go about securing the data, with the implicit assumption that sql injection from the php side (e.g. somewhere in that list of 300 scripts) is inevitable? My first-draft plan is to create multiple tiers of different permissioned users in the mysql database. In this way I can secure the data & scripts in most need of securing first ("private/secure" category), then the second tier of database tables & scripts ("semi-private"), and finally deal with the security of the rest of the php app overall (with the result of finally securing the database tables that essentially deal with "public" information, e.g. stuff that even just viewing the homepage requires). So, 3 database users (public, semi-private, and secure), with a different user connecting for each of three different groups of scripts (the secure scripts, the semi-private scripts, and the public scripts). In this way, I can prevent all access to "secure" from "public" or from "semi-private", and to "semi-private" from "public". Are there other alternatives that I should look into? If a tiered access system is the way to go, what approaches are best?

    Read the article

  • How to figure out what VirtualBox did?

    - by AndrejaKo
    I'm trying to boot a custom made-in-ASM OS on my recent laptop. The OS is intended to be installed on a floppy and during make creates a bootable floppy. Since I don't have a floppy drive, I installed it on a virtual floppy. After that I used WinToFlash's create bootable MS-DOS USB drive option to transfer the floppy image to an USB flash drive. Then I tried to boot my computer from it but got only a repeating broken string on screen. After all that I made a virtual hard disk image form the flash drive using this tutorial and tried to boot a virtual machine from it. First time I got same problem as on real computer. I then used the reset option and next time and every time after that OS booted correctly. My question is: How do I figure out what exactly happened to the virtual machine between first and second boot? UPDATE I just created a new VM with default settings for windows XP and it has the same problem that I have on a real computer. I was unable to reproduce the procedure which made the first VM work correctly.

    Read the article

  • Configuring three monitors with two Radeon X1600/X1650 graphics cards under Ubuntu

    - by cpm
    I have three SyncMaster 932a monitors I want to use with two Radeon X1600/X1650 cards under Linux. I am running X.org X Server 1.6.0, as provided by Ubuntu's Wubi installer. After turning off mirroring, I ended up with this xorg.conf: Section "Monitor" Identifier "Configured Monitor" EndSection Section "Screen" Identifier "Default Screen" Monitor "Configured Monitor" Device "Configured Video Device" SubSection "Display" Virtual 2560 1024 EndSubSection EndSection Section "Device" Identifier "Configured Video Device" EndSection The left monitor had a menu bar and a task bar, the center monitor was just desktop, and windows would maximize to the current monitor. The third monitor and second graphics card weren't being used at all. Then I changed my configuration to manually specify each card with their PCI bus: Section "ServerLayout" Identifier "TheLayout" Screen 0 "Radeon Screen 1" Screen 1 "Radeon Screen 2" RightOf "Radeon Screen 1" EndSection Section "Screen" Identifier "Radeon Screen 1" Monitor "Configured Monitor" Device "Radeon the First" SubSection "Display" Virtual 2560 1024 EndSubSection EndSection Section "Screen" Identifier "Radeon Screen 2" Monitor "Configured Monitor" Device "Radeon the Second" EndSection Section "Device" Identifier "Radeon the First" Driver "radeon" BusID "PCI:1:0:0" EndSection Section "Device" Identifier "Radeon the Second" Driver "radeon" BusID "PCI:2:0:0" EndSection Section "Monitor" Identifier "Configured Monitor" EndSection Now both the left and right monitors have task bars and menu bars. Windows cannot be dragged from the first two monitors to the third monitor. Also, maximizing in the left or center window fills both monitors. I also tried adding Option "Xinerama" "true" to the ServerLayout section. X11 wasn't able to start up. I want to: Allow moving windows along all three monitors. Maximizing only fills the current monitor. Either have menu/task bars on only the left monitor or all three monitors How can I make this possible?

    Read the article

  • Hyper-V vss-writer not making current copies

    - by Martinnj
    I'm using diskshadow to backup live Hyper-V machines on a Windows 2008 server. The backup consists of 3 scripts, the first will create the shadow copies and expose them, the second uses robocopy to copy them to a remote location and the third unexposes the shadow copies again. The first script – the one that runs correctly but fails to do what it's supposed to: # DiskShadow script file to backup VM from a Hyper-V host # First, delete any shadow copies of the drives. System Drives needs to be included. Delete Shadows volume C: Delete Shadows volume D: Delete Shadows volume E: #Ensure that shadow copies will persist after DiskShadow has run set context persistent # make sure the path already exists set verbose on begin backup add volume D: alias VirtualDisk add volume C: alias SystemDrive # verify the "Microsoft Hyper-V VSS Writer" writer will be included in the snapshot # NOTE: The writer GUID is exclusive for this install/machine, must be changed on other machines! writer verify {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de} create end backup # Backup is exposed as drive X: make sure your drive letter X is not in use Expose %VirtualDisk% X: Exit The next is just a robocopy and then an unexpose. Now, when I run the above script, I get no errors from it, except that the "BITS" writer has been excluded because none of its components are included. That's okay because I really only need the Hyper-V writer. Also I double checked the GUID for the writer, it's correct. During the time when the Hyper-V writer becomes active, 2 things will happen on the guest machines: The Debian/Linux machine will go to a saved state and restore when done, all fine. The Windows guests will "creating vss snapshop-sets" or something similar. Then X: gets exposed and I can copy the .vhd files over. The problem is, for some reason, the VHD files I get over seems to be old copies, they miss files, users and updates that are on the actual machines. I also tried putting the machines in a saved sate manually, didn't change the outcome. I hope someone here has an idea of how to solve this.

    Read the article

  • Printing from Firefox on different printers and setting the page details beforehand

    - by user1162541
    I´ve got an odd problem and I have not been able to fix this. I have a computer which is connected to two printers. One is a receipt printer (EPSON TM-U220), and the other one is an impact printer (Epson LX-300+). From Firefox, I need to print on both printers at different moments. So first I print on the receipt printer, then on the impact printer, etc. However, whenever I first print on the receipt printer, and then go back to the impact printer, the printout is only the width of the page of the receipt printer. That is, the page does not come out properly, just the left part of the page is used for printing and the right part is completely empty, as if I am just printing on the small receipt paper. And there is no way I can tell Firefox that I am printing on this larger printer. The second print on the impact printer goes fine. Firefox now knows it is printing on the impact printer, and it comes out properly on the full page width. But every first print on the impact printer is using the wrong paper size. How can I fix this? When I go to PAGE PREVIEW I can not set the printer UNTIL I actually print the page. If I go to PRINT PREVIEW CONFIGURE PAGE, I can not set the printer I will be using. I can only do so if I go to PRINT PREVIEW PRINT (here is the dropdown box to set the printer). But I can only set the printer and then click PRINT, or CANCEL. If I click PRINT, then the computer remembers the setting but that page will come our wrong, and when I click cancel it simply does not remember the printer I just set.

    Read the article

  • Flow of packet in network

    - by user58859
    I can't visualize in my mind the network traffic flow. eg. If there are 15 pc's in a LAN. When packet goes from router to local LAN, do it passes all the computers? Means did it goes to ehernet card of every computer and those computers accept the packet based on their physical address. To which pc the packet will go first? To the nearest to the router? What happen if that first pc captures that packet(though it is not for it)? What happens when a pc broadcast a message? Do it have to generate 14 packets for all the pc's or only one packet reach to all pc's? If it is one packet and captured by first pc, how other pc's can get that? I can't imagine how this traffic is exactly flows? May be my analogy is completely wrong. Can anybody explain me this? Thanks in advance.

    Read the article

  • Expresscard Not Detected in PCI-E Adapter

    - by maxpower47
    I'm trying to put an expresscard TV tuner (Avermedia HC82) into my HTPC using this expresscard to PCI-E adapter. I've verified that the tuner works fine in my laptop. The motherboard is a Biostar TF7050-M2. When I install it and turn it on, the light on the back of the adapter comes on fine (there are two indicator lights on the back to show if it is using PCI-E or USB communication, USB communication goes through a USB cable connected between the card and a header on the motherboard) showing that it is working in PCI-E mode. However, the device is never detected in Windows 7 Professional x64. The auto detect never happens, it doesn't show up in the device manager, and I can have it rescan for new hardware and nothing is found. I tested the whole setup (tuner + adapter) in another PC (also using Win 7 Pro x64) and it worked fine. I also tried: Plugging the adapter in to the PCI-E x16 slot on the motherboard (I verified first that the x16 slot worked by installing a video card in it) Booting into safe mode and rescanning Updating the chipset drivers Installing the tuner drivers first Using a different USB cable, plugged in to one of the known good ports on the back of the board Trying it without the USB cable plugged in Removing the other PCI cards that were installed on the board Looking through the BIOS for any setting that might be disabling it somehow to no avail. I'm at a loss for what else to try. I really don't want to RMA it (the shipping back to newegg will be almost as much as it cost to buy in the first place. Any ideas?

    Read the article

  • Understanding !d command in sed with respect to saves

    - by richardh
    I have a directory of tab-delimited text files and some have comments in the first few lines that I would like to delete. I know that the first good line starts with "Mark" so I can use /^Mark/,$!d to delete these comments. After this deletion I have several other replacements that I make in the (new) first line that has variable names. My question is, why do I have to save sed's output to get my script to work? I understand that if I line is deleted, then the output doesn't proceed downstream because there is no output. But if I don't delete (i.e., !d) then why do I have to save to file? Thanks! Here is my shell script. (I'm a sed newbie, so any other feedback is also appreciated.) #!/bin/bash for file in *.txt; do mv $file $file.old1 sed -e '/^Mark/,$!d' $file.old1 > $file.old2 sed -e '1s/\([Ss]\)hareholder/\1hrhldr/g'\ -e '1s/\([Ii]\)mmediate/\1mmdt/g'\ -e '1s/\([Nn]\)umber/\1o/g'\ -e '1s/\([Cc]\)ompany/\1o/g'\ -e '1s/\([Ii]\)nformation/\1nfo/g'\ -e '1s/\([Pp]\)ercentage/\1ct/g'\ -e '1s/\([Dd]\)omestic/\1om/g'\ -e '1s/\([Gg]\)lobal/\1lbl/g'\ -e '1s/\([Cc]\)ountry/\1ntry/g'\ -e '1s/\([Ss]\)ource/\1rc/g'\ -e '1s/\([Oo]\)wnership/\1wnrshp/g'\ -e '1s/\([Uu]\)ltimate/\1ltmt/g'\ -e '1s/\([Ii]\)ncorporation/\1ncorp/g'\ -e '1s/\([Tt]\)otal/\1ot/g'\ -e '1s/\([Dd]\)irect/\1ir/g'\ $file.old2 > $file rm -f $file.old* done

    Read the article

  • poor performance when deleteing many files

    - by choppy
    I've got two machines: The first is IBM Blade with 24 cores 96GB RAM and single local hard drive with 278GB divided to 4 partitions: 1. c: - 40GB; 3GB free 2. d: - 40GB; 37GB free 3. e: - 198322GB; 198.1 free 4. 100MB (EFI system Partition) Formatted with GPT The other is pizza server with 4 cores 8GB RAM and single local hard drive with 273GB divided to 3 partitions: 1. c: - 136.81; 20GB free 2. d: - 88.74GB; 87.91 free 3. e: - 47.85GB; 46.91 free Formatted with MBR I have two scripts, the first creates 20,000 files in one directory, each file size is 192KB, the second delete the folder (recursive) and prints how much time it toke to delete all files. The problem is on the first server (blade) it takes about 2 minutes to delete all 20,000 files while on the second (pizza) it takes about 4 seconds!? Both servers have clean windows server 2008R2 with no special application running on background. Any ideas what is going on?

    Read the article

  • How browsers handle multiple IPs

    - by Sandman4
    Can someone direct me to information on exact browsers behavior when browser gets multiple A records for a given hostname (say ip1 and ip2), and one of them is not accessible. I interested in EXACT details, like (but not limited to): Will browser get 2 IPs from OS, or it will get only one ? Which ip will browser try first (random or always the first one) ? Now, let's say browser started with the failed ip1 For how long will browser try ip1 ? If user hits "stop" while it waits for ip1, and then clicks refresh which IP will browser try ? What will happen when it times-out - will it start trying ip2 or give error ? (And if error, which ip will browser try when user clicks refresh). When user clicks refresh, will any browser attempt new DNS lookup ? Now let's assume browser tried working ip2 first. For the next page request, will browser still use ip2, or it may randomly switch ips ? For how long browsers keep IPs in their cache ? When browsers sends a new DNS request, and get SAME ips, will it CONTINUE to use the same known-to-be-working IP, or the process starts from scratch and it may try any of the two ? Of course it all may be browser dependent, and may also vary between versions and platforms, I'd be happy to have maximum of details. The purpose of this - I'm trying to understand what exactly users will experience when round-robin DNS based used and one of the hosts fails. Please, I'm NOT asking about how bad DNS load balancing is, and please refrain from answering "don't do it", "it's a bad idea", "you need heartbeat/proxy/BGP/whatever" and so on.

    Read the article

  • How can I restore my laptop from Windows 7 to its original Windows Vista recovery partition?

    - by Cam Jackson
    I bought my Acer laptop 4 years ago with Vista Home Premium x86. It has a recovery partition that I have used successfully in the past to format everything and reinstall Windows to factory settings. I have since upgraded to Windows 7, but I now need to get back to my original installation. Not sure what it's called, but I can successfully get into this recovery thingy: However, when I click the third option (for me I think it says 'Windows Image Recovery' or something like that) it tells me that it can't find any images to recover from :( I have checked and I don't have a windows.old that I can recover from either. One final note, if I launch diskmgmt.msc, these are the partitions: Why is the first partition shaded? Does that mean anything? Both of the 'unlettered' partitions are 100% empty. Did the Windows 7 upgrade process format my Vista system recovery partition?! And finally: How can I get back to my factory settings? EDIT: I did see this question, but neither of the answers apply to my situation. Edit to address jdh's answer: From what I can tell, I never get the option to boot the Vista recovery partition. After hitting F10, I get this screen, except it's partition 2, and I don't have the IN/MINT bit: I hit Escape, and then I get this screen, except without Ubuntu listed, and without the auto-countdown thing: I hit F8, and then I get this screen: I hit Enter on the first option, I end up at the screen in the first screen shot. As I said, from there I click the third option, and it fails to find the image, which I guess makes sense if it's only looking for a Windows 7 recovery. So I either need to make the Windows 7 tool see the Vista recovery partition, or I need the boot loader (?) to let me select Vista earlier in the process. Any ideas?

    Read the article

  • Help with Ubuntu and Windows, separate HDs

    - by LuxuryMode
    Need some major help. Running a Dell XPS/Dimension 630i. It came with "SATA 2 RAID 0 With Dual 500GB Hard Drives." I have installed a new, third non-raided drive and installed Ubuntu on it. So now I have Windows on the original hard drive and Ubuntu Linux on the new HD. When I get to the boot menu where I can select an OS, if I select windows I get an error: "No such drive, no such disk." Also, strangely in the first place, in order to even get to the bootloader menu I have had to disable ALL ports under the RAID config. Unless I do this, I will just get to a never-ending blinking cursor. I have tried every conceivable CMOS config and nothing else works. Tried setting port 3 (the new HD w/ Ubuntu) to first hard disk boot priority. Tried disabling all other ports and enabling the Ubuntu HD port and vice versa. I have some pictures of boot up: first one is strange error i get after messing with CMOS to finally get ubuntu install to work. http://imgur.com/5sqJa then boot menu: http://imgur.com/TWtLq then error: http://imgur.com/TJ1mS. Also, please note that I can actually access all files from the raided Windows drive through Ubuntu.

    Read the article

  • DRBD stacked resources: recovering from failure

    - by Marcus Downing
    We're running a stacked four-node DRBD setup like this: A --> B | | v v C D This means three DRBD resources running across these four servers. Servers A and B are Xen hosts running VMs, while servers C and D are for backups. A is in the same datacentre as C. From server A to server C, in the first datacentre, using protocol B From server B to server D, in the second datacentre, using protocol B From server A to server B, different datacentres, stacked resource using protocol A First question: booting a stacked resource We haven't got any vital data running on this setup yet - we're still making sure it works first. This means simulating power cuts, network outages etc and seeing what steps we need to recover. When we pull the power out of server A, both resources go down; it attempts to bring them back up at next boot. However, it only succeeds at bringing up the lower-level resource, A-C. The stacked resource A-B doesn't even try to connect, presumably because it can't find the device until it's a connected primary on the lower level. So if anything goes wrong we need to manually log in and bring that resource up, then start the virtual machine on top of it. Second question: setting the primary of a stacked resource Our lower-level resources are configured so that the right one is considered primary: resource test-AC { on A { ... } on C { ... } startup { become-primary-on A; } } But I don't see any way to do the same with a stacked resource, as the following isn't a valid config: resource test-AB { stacked-on-top-of test-AC { ... } stacked-on-top-of test-BD { ... } startup { become-primary-on test-AC; } } This too means that recovering from a failure requires manual intervention. Is there no way to set the automatic primary for a stacked resource?

    Read the article

< Previous Page | 456 457 458 459 460 461 462 463 464 465 466 467  | Next Page >