Search Results

Search found 35121 results on 1405 pages for 'object cache'.

Page 49/1405 | < Previous Page | 45 46 47 48 49 50 51 52 53 54 55 56  | Next Page >

  • How can I return an object into PHP userspace from my extension?

    - by John Factorial
    I have a C++ object, Graph, which contains a property named cat of type Category. I'm exposing the Graph object to PHP in an extension I'm writing in C++. As long as the Graph's methods return primitives like boolean or long, I can use the Zend RETURN_*() macros (e.g. RETURN_TRUE(); or RETURN_LONG(123);. But how can I make Graph-getCategory(); return a Category object for the PHP code to manipulate? I'm following the tutorial over at http://devzone.zend.com/article/4486, and here's the Graph code I have so far: #include "php_getgraph.h" zend_object_handlers graph_object_handlers; struct graph_object { zend_object std; Graph *graph; }; zend_class_entry *graph_ce; #define PHP_CLASSNAME "WFGraph" ZEND_BEGIN_ARG_INFO_EX(php_graph_one_arg, 0, 0, 1) ZEND_END_ARG_INFO() ZEND_BEGIN_ARG_INFO_EX(php_graph_two_args, 0, 0, 2) ZEND_END_ARG_INFO() void graph_free_storage(void *object TSRMLS_DC) { graph_object *obj = (graph_object*)object; delete obj-graph; zend_hash_destroy(obj-std.properties); FREE_HASHTABLE(obj-std.properties); efree(obj); } zend_object_value graph_create_handler(zend_class_entry *type TSRMLS_DC) { zval *tmp; zend_object_value retval; graph_object *obj = (graph_object*)emalloc(sizeof(graph_object)); memset(obj, 0, sizeof(graph_object)); obj-std.ce = type; ALLOC_HASHTABLE(obj-std.properties); zend_hash_init(obj-std.properties, 0, NULL, ZVAL_PTR_DTOR, 0); zend_hash_copy(obj-std.properties, &type-default_properties, (copy_ctor_func_t)zval_add_ref, (void*)&tmp, sizeof(zval*)); retval.handle = zend_objects_store_put(obj, NULL, graph_free_storage, NULL TSRMLS_CC); retval.handlers = &graph_object_handlers; return retval; } PHP_METHOD(Graph, __construct) { char *perspectives; int perspectives_len; Graph *graph = NULL; zval *object = getThis(); if(zend_parse_parameters(ZEND_NUM_ARGS() TSRMLS_CC, "s", &perspectives, &perspectives_len) == FAILURE) { RETURN_NULL(); } graph = new Graph(perspectives); graph_object *obj = (graph_object*)zend_object_store_get_object(object TSRMLS_CC); obj-graph = graph; } PHP_METHOD(Graph, hasCategory) { long perspectiveId; Graph *graph; graph_object *obj = (graph_object*)zend_object_store_get_object(getThis() TSRMLS_CC); graph = obj-graph; if (graph == NULL) { RETURN_NULL(); } if(zend_parse_parameters(ZEND_NUM_ARGS() TSRMLS_CC, "l", &perspectiveId) == FAILURE) { RETURN_NULL(); } RETURN_BOOL(graph-hasCategory(perspectiveId)); } PHP_METHOD(Graph, getCategory) { // what to do here? RETURN_TRUE; } function_entry php_getgraph_functions[] = { PHP_ME(Graph,__construct,NULL,ZEND_ACC_PUBLIC|ZEND_ACC_CTOR) PHP_ME(Graph,hasCategory,php_graph_one_arg,ZEND_ACC_PUBLIC) PHP_ME(Graph,getCategory,php_graph_one_arg,ZEND_ACC_PUBLIC) { NULL, NULL, NULL } }; PHP_MINIT_FUNCTION(getgraph) { zend_class_entry ce; INIT_CLASS_ENTRY(ce, PHP_CLASSNAME, php_getgraph_functions); graph_ce = zend_register_internal_class(&ce TSRMLS_CC); graph_ce-create_object = graph_create_handler; memcpy(&graph_object_handlers, zend_get_std_object_handlers(), sizeof(zend_object_handlers)); graph_object_handlers.clone_obj = NULL; return SUCCESS; } zend_module_entry getgraph_module_entry = { #if ZEND_MODULE_API_NO = 20010901 STANDARD_MODULE_HEADER, #endif PHP_GETGRAPH_EXTNAME, NULL, /* Functions */ PHP_MINIT(getgraph), NULL, /* MSHUTDOWN */ NULL, /* RINIT */ NULL, /* RSHUTDOWN */ NULL, /* MINFO */ #if ZEND_MODULE_API_NO = 20010901 PHP_GETGRAPH_EXTVER, #endif STANDARD_MODULE_PROPERTIES }; #ifdef COMPILE_DL_GETGRAPH extern "C" { ZEND_GET_MODULE(getgraph) } #endif

    Read the article

  • An error occurred creating the form. See Exception.InnerException for details. The error is: Object

    - by Ben
    I get this error when attempting to debug my form, I cannot see where at all the error could be (also does not highlight where), anyone have any suggestions? An error occurred creating the form. See Exception.InnerException for details. The error is: Object reference not set to an instance of an object. Public Class Form1 Dim dateCrap As String = "Date:" Dim IPcrap As String = "Ip:" Dim pcCrap As String = "Computer:" Dim programCrap As String = "Program:" Dim textz As String = TextBox1.Text Dim sep() As String = {vbNewLine & vbNewLine} Dim sections() As String = Text.Split(sep, StringSplitOptions.None) Dim NewArray() As String = TextBox1.Text.Split(vbNewLine) Private Sub Button2_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles Button2.Click For i = 0 To sections.Count - 1 TextBox2.Text = sections(i) Dim text2 As String = TextBox2.Text Dim sep2() As String = {vbNewLine & vbNewLine} Dim sections2() As String = Text.Split(sep, StringSplitOptions.None) Dim FTPinfo() As String = TextBox2.Text.Split(vbNewLine) Dim clsRequest As System.Net.FtpWebRequest = _ DirectCast(System.Net.WebRequest.Create(sections2(0).Replace("Url/Host:", "")), System.Net.FtpWebRequest) clsRequest.Credentials = New System.Net.NetworkCredential(sections2(1).Replace("Login:", ""), (sections2(2).Replace("Password:", ""))) clsRequest.Method = System.Net.WebRequestMethods.Ftp.UploadFile ' read in file... Dim bFile() As Byte = System.IO.File.ReadAllBytes(txtShellDir.Text) ' upload file... Dim clsStream As System.IO.Stream = clsRequest.GetRequestStream() clsStream.Write(bFile, 0, bFile.Length) clsStream.Close() clsStream.Dispose() Next End Sub Private Sub Button3_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles Button3.Click ListBox1.Items.Clear() Dim fdlg As OpenFileDialog = New OpenFileDialog() fdlg.Title = "Browse for the FTP List you wish to use." fdlg.InitialDirectory = Application.ExecutablePath fdlg.Filter = "All files (*.txt)|*.txt|txt files (*.txt)|*.txt" fdlg.FilterIndex = 2 fdlg.RestoreDirectory = True If fdlg.ShowDialog() = DialogResult.OK Then 'ListBox1.Items.AddRange(Split(My.Computer.FileSystem.ReadAllText(fdlg.FileName), vbNewLine)) TextBox1.Text = My.Computer.FileSystem.ReadAllText(fdlg.FileName) End If Dim tmp() As String = TextBox1.Text.Split(CChar(vbNewLine)) For Each line As String In tmp If line.Length > 1 Then TextBox1.AppendText(line & vbNewLine) End If Next TextBox1.Text = TextBox1.Text.Replace(" ", "") TextBox1.Text = TextBox1.Text.Replace("----------------------------------------------------------", vbNewLine) For Each item As String In NewArray ListBox1.Items.Add(item) Next Try For i = 0 To ListBox1.Items.Count - 1 If ListBox1.Items(i).Contains(dateCrap) Then ListBox1.Items.RemoveAt(i) End If Next Catch ex As Exception End Try Try For i = 0 To ListBox1.Items.Count - 1 If ListBox1.Items(i).Contains(IPcrap) Then ListBox1.Items.RemoveAt(i) End If Next Catch ex As Exception End Try Try For i = 0 To ListBox1.Items.Count - 1 If ListBox1.Items(i).Contains(pcCrap) Then ListBox1.Items.RemoveAt(i) End If Next Catch ex As Exception End Try Try For i = 0 To ListBox1.Items.Count - 1 If ListBox1.Items(i).Contains(programCrap) Then ListBox1.Items.RemoveAt(i) End If Next Catch ex As Exception End Try TextBox1.Text = "" For Each thing As Object In ListBox1.Items TextBox1.AppendText(thing.ToString & vbNewLine) Next End Sub Private Sub Button4_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) For i = 0 To ListBox1.SelectedItems.Count - 1 TextBox1.Text = TextBox1.Text & ListBox1.Items.Item(i).ToString() & vbNewLine Next End Sub End Class

    Read the article

  • How do I change the CSS from a web page contained in an object tag? (XHTML, jquery)

    - by Jose
    Hi! I've been having a bit of a problem with jQuery and XHTML. Basically, I've got an object tag that contains a Web Page in its data attribute. Now, what I want is that when I click a button I get this web page and dinamically change the CSS file it's currently using. I've tried to get the page by using jquery, but all I get is the object itself, not the webpage contained in the object. Thanks!! :)

    Read the article

  • How does one get access to the Flash object's vars in IE?

    - by Tim
    Is there a way in IE Browsers to access the Flash object? In this case it is made with mootools swiff. It´s working fine in all other browsers, because they can wrap this object correctly. But it does not work in IE. Here is the script: var swfObj = $('mbImage').getElement('object'); swfObj.get('data'); <--- Thats not working in IE

    Read the article

  • SQL SERVER – Guest Post – Jonathan Kehayias – Wait Type – Day 16 of 28

    - by pinaldave
    Jonathan Kehayias (Blog | Twitter) is a MCITP Database Administrator and Developer, who got started in SQL Server in 2004 as a database developer and report writer in the natural gas industry. After spending two and a half years working in TSQL, in late 2006, he transitioned to the role of SQL Database Administrator. His primary passion is performance tuning, where he frequently rewrites queries for better performance and performs in depth analysis of index implementation and usage. Jonathan blogs regularly on SQLBlog, and was a coauthor of Professional SQL Server 2008 Internals and Troubleshooting. On a personal note, I think Jonathan is extremely positive person. In every conversation with him I have found that he is always eager to help and encourage. Every time he finds something needs to be approved, he has contacted me without hesitation and guided me to improve, change and learn. During all the time, he has not lost his focus to help larger community. I am honored that he has accepted to provide his views on complex subject of Wait Types and Queues. Currently I am reading his series on Extended Events. Here is the guest blog post by Jonathan: SQL Server troubleshooting is all about correlating related pieces of information together to indentify where exactly the root cause of a problem lies. In my daily work as a DBA, I generally get phone calls like, “So and so application is slow, what’s wrong with the SQL Server.” One of the funny things about the letters DBA is that they go so well with Default Blame Acceptor, and I really wish that I knew exactly who the first person was that pointed that out to me, because it really fits at times. A lot of times when I get this call, the problem isn’t related to SQL Server at all, but every now and then in my initial quick checks, something pops up that makes me start looking at things further. The SQL Server is slow, we see a number of tasks waiting on ASYNC_IO_COMPLETION, IO_COMPLETION, or PAGEIOLATCH_* waits in sys.dm_exec_requests and sys.dm_exec_waiting_tasks. These are also some of the highest wait types in sys.dm_os_wait_stats for the server, so it would appear that we have a disk I/O bottleneck on the machine. A quick check of sys.dm_io_virtual_file_stats() and tempdb shows a high write stall rate, while our user databases show high read stall rates on the data files. A quick check of some performance counters and Page Life Expectancy on the server is bouncing up and down in the 50-150 range, the Free Page counter consistently hits zero, and the Free List Stalls/sec counter keeps jumping over 10, but Buffer Cache Hit Ratio is 98-99%. Where exactly is the problem? In this case, which happens to be based on a real scenario I faced a few years back, the problem may not be a disk bottleneck at all; it may very well be a memory pressure issue on the server. A quick check of the system spec’s and it is a dual duo core server with 8GB RAM running SQL Server 2005 SP1 x64 on Windows Server 2003 R2 x64. Max Server memory is configured at 6GB and we think that this should be enough to handle the workload; or is it? This is a unique scenario because there are a couple of things happening inside of this system, and they all relate to what the root cause of the performance problem is on the system. If we were to query sys.dm_exec_query_stats for the TOP 10 queries, by max_physical_reads, max_logical_reads, and max_worker_time, we may be able to find some queries that were using excessive I/O and possibly CPU against the system in their worst single execution. We can also CROSS APPLY to sys.dm_exec_sql_text() and see the statement text, and also CROSS APPLY sys.dm_exec_query_plan() to get the execution plan stored in cache. Ok, quick check, the plans are pretty big, I see some large index seeks, that estimate 2.8GB of data movement between operators, but everything looks like it is optimized the best it can be. Nothing really stands out in the code, and the indexing looks correct, and I should have enough memory to handle this in cache, so it must be a disk I/O problem right? Not exactly! If we were to look at how much memory the plan cache is taking by querying sys.dm_os_memory_clerks for the CACHESTORE_SQLCP and CACHESTORE_OBJCP clerks we might be surprised at what we find. In SQL Server 2005 RTM and SP1, the plan cache was allowed to take up to 75% of the memory under 8GB. I’ll give you a second to go back and read that again. Yes, you read it correctly, it says 75% of the memory under 8GB, but you don’t have to take my word for it, you can validate this by reading Changes in Caching Behavior between SQL Server 2000, SQL Server 2005 RTM and SQL Server 2005 SP2. In this scenario the application uses an entirely adhoc workload against SQL Server and this leads to plan cache bloat, and up to 4.5GB of our 6GB of memory for SQL can be consumed by the plan cache in SQL Server 2005 SP1. This in turn reduces the size of the buffer cache to just 1.5GB, causing our 2.8GB of data movement in this expensive plan to cause complete flushing of the buffer cache, not just once initially, but then another time during the queries execution, resulting in excessive physical I/O from disk. Keep in mind that this is not the only query executing at the time this occurs. Remember the output of sys.dm_io_virtual_file_stats() showed high read stalls on the data files for our user databases versus higher write stalls for tempdb? The memory pressure is also forcing heavier use of tempdb to handle sorting and hashing in the environment as well. The real clue here is the Memory counters for the instance; Page Life Expectancy, Free List Pages, and Free List Stalls/sec. The fact that Page Life Expectancy is fluctuating between 50 and 150 constantly is a sign that the buffer cache is experiencing constant churn of data, once every minute to two and a half minutes. If you add to the Page Life Expectancy counter, the consistent bottoming out of Free List Pages along with Free List Stalls/sec consistently spiking over 10, and you have the perfect memory pressure scenario. All of sudden it may not be that our disk subsystem is the problem, but is instead an innocent bystander and victim. Side Note: The Page Life Expectancy counter dropping briefly and then returning to normal operating values intermittently is not necessarily a sign that the server is under memory pressure. The Books Online and a number of other references will tell you that this counter should remain on average above 300 which is the time in seconds a page will remain in cache before being flushed or aged out. This number, which equates to just five minutes, is incredibly low for modern systems and most published documents pre-date the predominance of 64 bit computing and easy availability to larger amounts of memory in SQL Servers. As food for thought, consider that my personal laptop has more memory in it than most SQL Servers did at the time those numbers were posted. I would argue that today, a system churning the buffer cache every five minutes is in need of some serious tuning or a hardware upgrade. Back to our problem and its investigation: There are two things really wrong with this server; first the plan cache is excessively consuming memory and bloated in size and we need to look at that and second we need to evaluate upgrading the memory to accommodate the workload being performed. In the case of the server I was working on there were a lot of single use plans found in sys.dm_exec_cached_plans (where usecounts=1). Single use plans waste space in the plan cache, especially when they are adhoc plans for statements that had concatenated filter criteria that is not likely to reoccur with any frequency.  SQL Server 2005 doesn’t natively have a way to evict a single plan from cache like SQL Server 2008 does, but MVP Kalen Delaney, showed a hack to evict a single plan by creating a plan guide for the statement and then dropping that plan guide in her blog post Geek City: Clearing a Single Plan from Cache. We could put that hack in place in a job to automate cleaning out all the single use plans periodically, minimizing the size of the plan cache, but a better solution would be to fix the application so that it uses proper parameterized calls to the database. You didn’t write the app, and you can’t change its design? Ok, well you could try to force parameterization to occur by creating and keeping plan guides in place, or we can try forcing parameterization at the database level by using ALTER DATABASE <dbname> SET PARAMETERIZATION FORCED and that might help. If neither of these help, we could periodically dump the plan cache for that database, as discussed as being a problem in Kalen’s blog post referenced above; not an ideal scenario. The other option is to increase the memory on the server to 16GB or 32GB, if the hardware allows it, which will increase the size of the plan cache as well as the buffer cache. In SQL Server 2005 SP1, on a system with 16GB of memory, if we set max server memory to 14GB the plan cache could use at most 9GB  [(8GB*.75)+(6GB*.5)=(6+3)=9GB], leaving 5GB for the buffer cache.  If we went to 32GB of memory and set max server memory to 28GB, the plan cache could use at most 16GB [(8*.75)+(20*.5)=(6+10)=16GB], leaving 12GB for the buffer cache. Thankfully we have SQL Server 2005 Service Pack 2, 3, and 4 these days which include the changes in plan cache sizing discussed in the Changes to Caching Behavior between SQL Server 2000, SQL Server 2005 RTM and SQL Server 2005 SP2 blog post. In real life, when I was troubleshooting this problem, I spent a week trying to chase down the cause of the disk I/O bottleneck with our Server Admin and SAN Admin, and there wasn’t much that could be done immediately there, so I finally asked if we could increase the memory on the server to 16GB, which did fix the problem. It wasn’t until I had this same problem occur on another system that I actually figured out how to really troubleshoot this down to the root cause.  I couldn’t believe the size of the plan cache on the server with 16GB of memory when I actually learned about this and went back to look at it. SQL Server is constantly telling a story to anyone that will listen. As the DBA, you have to sit back and listen to all that it’s telling you and then evaluate the big picture and how all the data you can gather from SQL about performance relate to each other. One of the greatest tools out there is actually a free in the form of Diagnostic Scripts for SQL Server 2005 and 2008, created by MVP Glenn Alan Berry. Glenn’s scripts collect a majority of the information that SQL has to offer for rapid troubleshooting of problems, and he includes a lot of notes about what the outputs of each individual query might be telling you. When I read Pinal’s blog post SQL SERVER – ASYNC_IO_COMPLETION – Wait Type – Day 11 of 28, I noticed that he referenced Checking Memory Related Performance Counters in his post, but there was no real explanation about why checking memory counters is so important when looking at an I/O related wait type. I thought I’d chat with him briefly on Google Talk/Twitter DM and point this out, and offer a couple of other points I noted, so that he could add the information to his blog post if he found it useful.  Instead he asked that I write a guest blog for this. I am honored to be a guest blogger, and to be able to share this kind of information with the community. The information contained in this blog post is a glimpse at how I do troubleshooting almost every day of the week in my own environment. SQL Server provides us with a lot of information about how it is running, and where it may be having problems, it is up to us to play detective and find out how all that information comes together to tell us what’s really the problem. This blog post is written by Jonathan Kehayias (Blog | Twitter). Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: MVP, Pinal Dave, PostADay, Readers Contribution, SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, SQL Wait Stats, SQL Wait Types, T SQL, Technology

    Read the article

  • Syntactic sugar in PHP with static functions

    - by Anna
    The dilemma I'm facing is: should I use static classes for the components of an application just to get nicer looking API? Example - the "normal" way: // example component class Cache{ abstract function get($k); abstract function set($k, $v); } class APCCache extends Cache{ ... } class application{ function __construct() $this->cache = new APCCache(); } function whatever(){ $this->cache->add('blabla'); print $this->cache->get('blablabla'); } } Notice how ugly is this->cache->.... But it gets waay uglier when you try to make the application extensible trough plugins, because then you have to pass the application instance to its plugins, and you get $this->application->cache->... With static functions: interface CacheAdapter{ abstract function get($k); abstract function set($k, $v); } class Cache{ public static $ad; public function setAdapter(CacheAdapter $a){ static::$ad = $ad; } public static function get($k){ return static::$ad->get($k); } ... } class APCCache implements CacheAdapter{ ... } class application{ function __construct(){ cache::setAdapter(new APCCache); } function whatever() cache::add('blabla', 5); print cache::get('blabla'); } } Here it looks nicer because you just call cache::get() everywhere. The disadvantage is that I loose the possibility to extend this class easily. But I've added a setAdapter method to make the class extensible to some point. I'm relying on the fact that I won't need to rewrite to replace the cache wrapper, ever, and that I won't need to run multiple application instances simultaneously (it's basically a site - and nobody works with two sites at the same time) So, am doing it wrong?

    Read the article

  • Loose typing not applied to objects

    - by TecBrat
    I have very little experience working with classes and object. I work in a loosely typed language, PHP. I was working with a SimpleXML object and ran into a problem where I was trying to do math with an element of that object like $results->ProductDetail->{'Net'.$i}; If I echoed that value, I'd get 0.53 but when I tried to do math with it, it was converted to 0 Is there a reason that a loosely typed language would not recognize that as a float and handle it as such? Why would "echo" handle it as a string but the math fail to convert it? Example: $xml='<?xml version="1.0" encoding="UTF-8" ?>'; $xml.='<Test> <Item> <Price>0.53</Price> </Item> </Test>'; $result=simplexml_load_string($xml); var_dump($result->Item->Price); echo '<br>'; echo $result->Item->Price; echo '<br>'; echo 1+$result->Item->Price; echo '<br>'; echo 1+(float)$result->Item->Price; Output: object(SimpleXMLElement)#4 (1) { [0]=> string(4) "0.53" } 0.53 1 1.53

    Read the article

  • Game Messaging System Design

    - by you786
    I'm making a simple game, and have decided to try to implement a messaging system. The system basically looks like this: Entity generates message - message is posted to global message queue - messageManager notifies every object of the new message through onMessageReceived(Message msg) - if object wants, it acts on the message. The way I'm making message objects is like this: //base message class, never actually instantiated abstract class Message{ Entity sender; } PlayerDiedMessage extends Message{ int livesLeft; } Now my SoundManagerEntity can do something like this in its onMessageReceived() method public void messageReceived(Message msg){ if(msg instanceof PlayerDiedMessage){ PlayerDiedMessage diedMessage = (PlayerDiedMessage) msg; if(diedMessage.livesLeft == 0) playSound(SOUND_DEATH); } } The pros to this approach: Very simple and easy to implement The message can contain as much as information as you want, because you can just create a new Message subclass that has whatever info necessary. The cons: I can't figure out how I can recycle Message objects to a object pool, unless I have a different pool for each subclass of Message. So I have lots and lots of object creation/memory allocation over time. Can't send a message to a specific recipient, but I haven't needed that yet in my game so I don't mind it too much. What am I missing here? There must be a better implementation or some idea that I'm missing.

    Read the article

  • Relationship between SOA and OOA

    - by TheSilverBullet
    Thomas Erl defines SOA as follows in his site: Service-oriented computing represents a new generation distributed computing platform. As such, it encompasses many things, including its own design paradigm and design principles, design pattern catalogs, pattern languages, a distinct architectural model, and related concepts, technologies, and frameworks. This definitely sounds like a whole new category which is parallel to object orientation. Almost one in which you would expect an entirely new language to exist for. Like procedural C and object oriented C#. Here is my understanding: In real life, we don't have entirely new language for SOA. And most application which have SOA architecture have an object oriented design underneath it. SOA is a "strategy" to make the entire application/service distributed and reliable. SOA needs OOPS working underneath it. Is this correct? Where does SOA (if at all it does) fit in with object oriented programming practices? Edit: I have learnt through answers that OOA and SOA work with each other and cannot be compared (in a "which is better" way). I have changed the title to "Relationship between SOA and OOA" rather than "comparison".

    Read the article

  • How are objects modelled in a functional programming language?

    - by Giorgio
    In an answer to this question (written by Pete) there are some considerations about OOP versus FP. In particular, it is suggested that FP languages are not very suitable for modelling (persistent) objects that have an identity and a mutable state. I was wondering if this is true or, in other words, how one would model objects in a functional programming language. From my basic knowledge of Haskell I thought that one could use monads in some way, but I really do not know enough on this topic to come up with a clear answer. So, how are entities with an identity and a mutable persistent state normally modelled in a functional language? EDIT Here are some further details to clarify what I have in mind. Take a typical Java application in which I can (1) read a record from a database table into a Java object, (2) modify the object in different ways, (3) save the modified object to the database. How would this be implemented e.g. in Haskell? I would initially read the record into a record value (defined by a data definition), perform different transformations by applying functions to this initial value (each intermediate value is a new, modified copy of the original record) and then write the final record value to the database. Is this all there is to it? How can I ensure that at each moment in time only one copy of the record is valid / accessible? One does not want to have different immutable values representing different snapshots of the same object to be accessible at the same time.

    Read the article

  • How to clear Windows disk read cache?

    - by Sebastiaan Megens
    For performance testing I need to clear Windows' disk read cache. I tried googling but I couldn't find anything other than rebooting or other manual stuff. Before I give in and do that, I'd like to know if anyone knows of a way to clear Windows disk read cache. I'm testing on Windows 7, but I'm also interested in Windows XP solutions.

    Read the article

  • problem with custom NSProtocol and caching on iPhone

    - by TomSwift
    My iPhone app embeds a UIWebView which loads html via a custom NSProtocol handler I have registered. My problem is that resources referenced in the returned html, which are also loaded via my custom protocol handler, are cached and never reloaded. In particular, my stylesheet is cached: <link rel="stylesheet" type="text/css" href="./styles.css" /> The initial request to load the html in the UIWebView looks like this: NSString* strUrl = [NSMutableString stringWithFormat: @"myprotocol:///entry?id=%d", entryID ]; NSURL* url = [NSURL URLWithString: strUrl]; [_pCurrentWebView loadRequest: [NSURLRequest requestWithURL: url cachePolicy: NSURLRequestReloadIgnoringLocalCacheData timeoutInterval: 60 ]]; (note the cache policy is set to ignore, and I've verified this cache policy carries through to subsequent requests for page resources on the initial load) The protocol handler loads the html from a database and returns it to the client using code like this: // create the response record NSURLResponse *response = [[NSURLResponse alloc] initWithURL: [request URL] MIMEType: mimeType expectedContentLength: -1 textEncodingName: textEncodingName]; // get a reference to the client so we can hand off the data id client = [self client]; // turn off caching for this response data [client URLProtocol: self didReceiveResponse:response cacheStoragePolicy: NSURLCacheStorageNotAllowed]; // set the data in the response to our jfif data [client URLProtocol: self didLoadData:data]; [data release]; (Note the response cache policy is "not allowed"). Any ideas how I can make it NOT cache my styles.css resource? I need to be able to dynamically alter the content of this resource on subsequent loads of html that references this file. I thought clearing the shared url cache would work, but it doesnt: [[NSURLCache sharedURLCache] removeAllCachedResponses]; One thing that does work, but it's terribly inefficient, is to dynamically cache-bust the url for the stylesheet by adding a timestamp parameter: <link rel="stylesheet" type="text/css" href="./styles.css?ts=1234567890" /> To make this work I have to load my html from the db, search and replace the url for the stylesheet with a cache-busting parameter that changes on each request. I'd rather not do this. My presumption is that there is no problem if I were to load my content via the built-in HTTP protocol. In that case, I'm guessing that the UIWebView looks at any Cache-Control flags in the NSURLHTTPResponse object's http headers and abides by them. Since my NSURLResponseObject has no http headers (it's not http...) then perhaps UIWebView just decides to cached the resource (ignoring the NSURLRequest caching directive?). Ideas???

    Read the article

  • [Flex] Caching canvas into ByteArray

    - by Eugene
    Task: (all in code, not visual) create a canvas, place into it some labels and draw some lines, then cache it as byteArray. The problem is that if I cache an object that is already drawed on the screen, it works great, but if I cache a canvas, that have been created few lines earlier, this results white image. Is there any solution to cache a display object, that was created in code, but not intended to be displayed at all?

    Read the article

  • Can I use a static cache Helper method in a NET MVC controller?

    - by Euston
    I realise there have been a few posts regarding where to add a cache check/update and the separation of concerns between the controller, the model and the caching code. There are two great examples that I have tried to work with but being new to MVC I wonder which one is the cleanest and suits the MVC methodology the best? I know you need to take into account DI and unit testing. Example 1 (Helper method with delegate) ...in controller var myObject = CacheDataHelper.Get(thisID, () => WebServiceServiceWrapper.GetMyObjectBythisID(thisID)); Example 2 (check for cache in model class) in controller var myObject = WebServiceServiceWrapper.GetMyObjectBythisID(thisID)); then in model class.............. if (!CacheDataHelper.Get(cachekey, out myObject)) { //do some repository processing // Add obect to cache CacheDataHelper.Add(myObject, cachekey); } Both use a static cache helper class but the first example uses a method signature with a delegate method passed in that has the name of the repository method being called. If the data is not in cache the method is called and the cache helper class handles the adding or updating to the current cache. In the second example the cache check is part of the repository method with an extra line to call the cache helper add method to update the current cache. Due to my lack of experience and knowledge I am not sure which one is best suited to MVC. I like the idea of calling the cache helper with the delegate method name in order to remove any cache code in the repository but I am not sure if using the static method in the controller is ideal? The second example deals with the above but now there is no separation between the caching check and the repository lookup. Perhaps that is not a problem as you know it requires caching anyway?

    Read the article

  • flash object not working on intranet anymore?

    - by JonH
    Not sure how or why this happened, its rather all of a sudden. I've got a flash object on a site with something to this effect: <OBJECT codeBase="http://download.macromedia.com/pub/shockwave/cabs/flash/swflash.cab#version=6,0,29,0" classid="clsid:D27CDB6E-AE6D-11cf-96B8-444553540000" data="data:application/x-oleobject;base64,btt80m2uzxGWuERFU1QAAGdVZlUACQAAAR8AADwHAAAIAAIAAAAAAAgAAAAAAAgAAAAAAAgADgAAAFcAaQBuAGQAbwB3AAAACAAGAAAALQAxAAAACAAGAAAALQAxAAAACAAKAAAASABpAGcAaAAAAAgAAgAAAAAACAAGAAAALQAxAAAACAAAAAAACAACAAAAAAAIABAAAABTAGgAbwB3AEEAbABsAAAACAAEAAAAMAAAAAgABAAAADAAAAAIAAIAAAAAAAgAAAAAAAgAAgAAAAAADQAAAAAAAAAAAAAAAAAAAAAACAAEAAAAMQAAAAgABAAAADAAAAAIAAAAAAAIAAQAAAAwAAAACAAIAAAAYQBsAGwAAAAIAAwAAABmAGEAbABzAGUAAAA=" width="300" align="top" height="70" VIEWASTEXT> <embed src="../flash/quikfix.swf" width="300" height="70" align="top" quality="high" pluginspage="http://www.macromedia.com/go/getflashplayer" type="application/x-shockwave-flash"> </embed> </OBJECT> That comes up completly fine in Chrome and FireFox but in IE8 it doesnt come up but shows the page as loading this file, and it just sits there trying to load it.. This is a production app for over 6 years and this just suddenly happened. If I right click this flash object it says "Movie Not Loaded" and underneath it the version Flash Player 10.2.152.32... Any ideas ?

    Read the article

  • SQL SERVER – Find Referenced or Referencing Object in SQL Server using sys.sql_expression_dependencies

    - by pinaldave
    A very common question which I often receive are: How do I find all the tables used in a particular stored procedure? How do I know which stored procedures are using a particular table? Both are valid question but before we see the answer of this question – let us understand two small concepts – Referenced and Referencing. Here is the sample stored procedure. CREATE PROCEDURE mySP AS SELECT * FROM Sales.Customer GO Reference: The table Sales.Customer is the reference object as it is being referenced in the stored procedure mySP. Referencing: The stored procedure mySP is the referencing object as it is referencing Sales.Customer table. Now we know what is referencing and referenced object. Let us run following queries. I am using AdventureWorks2012 as a sample database. If you do not have SQL Server 2012 here is the way to get SQL Server 2012 AdventureWorks database. Find Referecing Objects of a particular object Here we are finding all the objects which are using table Customer in their object definitions (regardless of the schema). USE AdventureWorks GO SELECT referencing_schema_name = SCHEMA_NAME(o.SCHEMA_ID), referencing_object_name = o.name, referencing_object_type_desc = o.type_desc, referenced_schema_name, referenced_object_name = referenced_entity_name, referenced_object_type_desc = o1.type_desc, referenced_server_name, referenced_database_name --,sed.* -- Uncomment for all the columns FROM sys.sql_expression_dependencies sed INNER JOIN sys.objects o ON sed.referencing_id = o.[object_id] LEFT OUTER JOIN sys.objects o1 ON sed.referenced_id = o1.[object_id] WHERE referenced_entity_name = 'Customer' The above query will return all the objects which are referencing the table Customer. Find Referenced Objects of a particular object Here we are finding all the objects which are used in the view table vIndividualCustomer. USE AdventureWorks GO SELECT referencing_schema_name = SCHEMA_NAME(o.SCHEMA_ID), referencing_object_name = o.name, referencing_object_type_desc = o.type_desc, referenced_schema_name, referenced_object_name = referenced_entity_name, referenced_object_type_desc = o1.type_desc, referenced_server_name, referenced_database_name --,sed.* -- Uncomment for all the columns FROM sys.sql_expression_dependencies sed INNER JOIN sys.objects o ON sed.referencing_id = o.[object_id] LEFT OUTER JOIN sys.objects o1 ON sed.referenced_id = o1.[object_id] WHERE o.name = 'vIndividualCustomer' The above query will return all the objects which are referencing the table Customer. I am just glad to write above query. There are more to write to this subject. In future blog post I will write more in depth about other DMV which also aids in finding referenced data. Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: PostADay, SQL, SQL Authority, SQL DMV, SQL Query, SQL Server, SQL Tips and Tricks, SQL Utility, T SQL, Technology

    Read the article

  • Game Components, Game Managers and Object Properties

    - by George Duckett
    I'm trying to get my head around component based entity design. My first step was to create various components that could be added to an object. For every component type i had a manager, which would call every component's update function, passing in things like keyboard state etc. as required. The next thing i did was remove the object, and just have each component with an Id. So an object is defined by components having the same Ids. Now, i'm thinking that i don't need a manager for all my components, for example i have a SizeComponent, which just has a Size property). As a result the SizeComponent doesn't have an update method, and the manager's update method does nothing. My first thought was to have an ObjectProperty class which components could query, instead of having them as properties of components. So an object would have a number of ObjectProperty and ObjectComponent. Components would have update logic that queries the object for properties. The manager would manage calling the component's update method. This seems like over-engineering to me, but i don't think i can get rid of the components, because i need a way for the managers to know what objects need what component logic to run (otherwise i'd just remove the component completely and push its update logic into the manager). Is this (having ObjectProperty, ObjectComponent and ComponentManager classes) over-engineering? What would be a good alternative?

    Read the article

  • Installing a DLL to Global assembly cache (GAC)

    - by DAXShekhar
    Install you DLL assembly by using the ‘gacutil.exe’, before installing the DLL ensure it has a strong name, to assign a strong name refer to the link Assigning a DLL strong name .   1) open the Command prompt, and navigate to the folder of gacutil. 2) To install a DLL assembly gacutil /I "C:\[PathToBinDirectoryInVSProject]\gac.dll" 3) To uninstall gacutil /U  “Name_of_The_DLL”

    Read the article

  • OpenGL - have object follow mouse

    - by kevin james
    I want to have an object follow around my mouse on the screen in OpenGL. (I am also using GLEW, GLFW, and GLM). The best idea I've come up with is: Get the coordinates within the window with glfwGetCursorPos. The window was created with window = glfwCreateWindow( 1024, 768, "Test", NULL, NULL); and the code to get coordinates is double xpos, ypos; glfwGetCursorPos(window, &xpos, &ypos); Next, I use GLM unproject, to get the coordinates in "object space" glm::vec4 viewport = glm::vec4(0.0f, 0.0f, 1024.0f, 768.0f); glm::vec3 pos = glm::vec3(xpos, ypos, 0.0f); glm::vec3 un = glm::unProject(pos, View*Model, Projection, viewport); There are two potential problems I can already see. The viewport is fine, as the initial x,y, coordinates of the lower left are indeed 0,0, and it's indeed a 1024*768 window. However, the position vector I create doesn't seem right. The Z coordinate should probably not be zero. However, glfwGetCursorPos returns 2D coordinates, and I don't know how to go from there to the 3D window coordinates, especially since I am not sure what the 3rd dimension of the window coordinates even means (since computer screens are 2D). Then, I am not sure if I am using unproject correctly. Assume the View, Model, Projection matrices are all OK. If I passed in the correct position vector in Window coordinates, does the unproject call give me the coordinates in Object coordinates? I think it does, but the documentation is not clear. Finally, to each vertex of the object I want to follow the mouse around, I just increment the x coordinate by un[0], the y coordinate by -un[1], and the z coordinate by un[2]. However, since my position vector that is being unprojected is likely wrong, this is not giving good results; the object does move as my mouse moves, but it is offset quite a bit (i.e. moving the mouse a lot doesn't move the object that much, and the z coordinate is very large). I actually found that the z coordinate un[2] is always the same value no matter where my mouse is, probably because the position vector I pass into unproject always has a value of 0.0 for z. Edit: The (incorrectly) unprojected x-values range from about -0.552 to 0.552, and the y-values from about -0.411 to 0.411.

    Read the article

  • How to implement Cache in web apps?

    - by Jhonnytunes
    This is really two questions. Im doing a project for the university for storing baseball players statitics, but from baseball data I have to calculate the score by year for the player who is beign displayed. The background is, lets say 10, 000 users hit the player "Alex Rodriguez", the application have to calculate 10, 000 the A-Rod stats by years intead of just read it from some where is temporal saved. Here I go: What is the best method for caching this type of data? Do I have to used the same database, and some temporal values on the same database, or create a Web Service for that? What reading about web caching so you recommend?

    Read the article

  • How to mock a dynamic object

    - by Daniel Cazzulino
    Someone asked me how to mock a dynamic object with Moq, which might be non-obvious. Given the following interface definition: public interface IProject { string Name { get; } dynamic Data { get; } } When you try to setup the mock for the dynamic property values, you get:   What’s important to realize is that a dynamic object is just a plain object, whose properties happen to be resolved at runtime. Kinda like reflection, if you will: all public properties of whatever object happens to be the instance, will be resolved just fine at runtime. Therefore, one way to mock this dynamic is to just create an anonymous type with the properties we want, and set the dynamic property to return that:...Read full article

    Read the article

< Previous Page | 45 46 47 48 49 50 51 52 53 54 55 56  | Next Page >