Search Results

Search found 15007 results on 601 pages for 'array'.

Page 495/601 | < Previous Page | 491 492 493 494 495 496 497 498 499 500 501 502  | Next Page >

  • Repairing inconsistent pages in database

    - by Raj
    We have a SQL 2000 DB. The server crashed due to Raid array failure. Now when we run DBCC CHECKDB, we get an error that there are 27 consistency errors in 9 pages. When we run DBCC PAGE on these pages, we get this: Msg 8939, Level 16, State 106, Line 1 Table error: Object ID 1397580017, index ID 2, page (1:8404521). Test (m_freeCnt == freeCnt) failed. Values are 2 and 19. Msg 8939, Level 16, State 108, Line 1 Table error: Object ID 1397580017, index ID 2, page (1:8404521). Test (emptySlotCnt == 0) failed. Values are 1 and 0. Since the indicated index is non-clustered and is created by a unique constarint that includes 2 columns, we tried dropping and recreating the index. This resulted in the following error: CREATE UNIQUE INDEX terminated because a duplicate key was found for index ID 2. Most significant primary key is '3280'. The statement has been terminated. However running Select var_id,result_on from tests group by var_id,result_on having count(*)>1 returns 0 rows. Here is what we are planning to do: Restore a pre-server crash copy of the DB and run DBCC CHECKDB If that returns clean, then restore again with no recovery Apply all subequent TLOG backups Stop production app, take a tail log backup and apply that too Drop prod DB and rename the freshly restored DB to make it prod Start prod app Could someone please punch holes in this approach? Maybe, suggest a different approach? What we need is minimum downtime. SQL 2000 DB Size 94 GB The table that has corrupt pages has 460 Million+ rows of data Thanks for the help. Raj

    Read the article

  • Where do I connect the HDD LED wires on my RAID adapter?

    - by Giffyguy
    I'm using a Promise FastTrak TX8660 with RAID 5. The manual (and Google) just doesn't seem to explain how exactly to connect a standard two-pin HDD LED wire to the eight available pins on the card. The Manual just says - To connect your LED, follow the following diagram: The card itself resembles the diagram: But it doesn't make any sense to me. All I have is a two-pin connecter for HDD LED on the front of my computer case. I don't need anything fancy like the fault LED or seperate indicators for each drive. I just want to be able to see when my RAID 5 array is working, that's all. I don't know what the "R" and "G" stand for, but my HDD LED wires are red and white. I tried connecting the red wire to the "R" pin and the white wire to the "G" pin, but that just makes the LED on the front of my case light up indefinitely, even when the computer is idle. Which pins am I suppose to connect the HDD LED header to for basic activity indication?

    Read the article

  • Are HDMI to VGA Adapters Really Device-Specific?

    - by allquixotic
    There are a lot of devices on the market right now (especially mobile devices) with a Micro-HDMI or Mini-HDMI port and no VGA or D-Sub output. Most manufacturers of said devices sell a cable that looks something like this: I have yet to find a cable like this that claims to work on a wide array of devices. In general, these cables claim to work with one specific device only. The way these cables work, I think, is that analog VGA signals are sent from the HDMI port on the device. This should work for devices that have special hardware on the motherboard/GPU capable of driving this. Is it the case that these cables have to be custom designed for each device? Or, is it rather that any device which possesses this special "signaling of analog VGA over the HDMI port" can be made to work with a cable that is physically compatible (i.e. the HDMI end plugs into the device and the VGA end accepts a VGA monitor cable)? Note that I am not looking for a product recommendation, just a conceptual clarification on what exactly these devices are doing. Also, a few remarks: The cables like the one depicted here are not digital to analog converters. I know about these: they are expensive, and they are the ONLY solution if your device only outputs a digital signal and is incapable of driving analog VGA over the HDMI port. The cables like the one depicted here are not straight crossover cables from VGA to HDMI, either. The crossover cables are designed to send a digital HDMI signal over the VGA port's wires; that is, the wire protocol is HDMI (digital) but the physical pinout is the same as VGA, even though nothing analog is happening. Once again, this is not the behavior that, I believe, the devices which I'm talking about in this question are doing. The cabling and devices that this question is about transmit the analog VGA data over the HDMI port (the HDMI port is in the device outputting the data, and the VGA side is the monitor/projector).

    Read the article

  • 24TB RAID 6 configuration

    - by Phil
    I am in charge of a new website in a niche industry that stores lots of data (10+ TB per client, growing to 2 or 3 clients soon). We are considering ordering about $5000 worth of 3TB drives (10 in a RAID 6 configuration and 10 for backup), which will give us approximately 24 TB of production storage. The data will be written once and remain unmodified for the lifetime of the website, so we only need to do a backup one time. I understand basic RAID theory, however I am not experienced with it. My question is, does this sound like a good configuration? What potential problems could this setup cause? Also, what is the best way to do a one-time backup? Have two RAID 6 arrays, one for offsite backup and one for production? Or should I backup the RAID 6 production array to a JBOD? EDIT: The data server is running Windows 2008 Server x64. EDIT 2: To reduce rebuild time, what would you think about using two RAID 5's instead of one RAID 6?

    Read the article

  • Can't get an IBM xSeries 345 server to load Windows Server 2003 using ServerGuide utility

    - by Kyle Noland
    I have a client that has an IBM xSeries 345 eServer. Per the IBM support website, I have downloaded the ServerGuide Setup 7.4.17 installation ISO and burned a bootable CD. The CD boots fine and loads the utility. I walk through the following screens without any issue: Set the date and Time Detect the IBM ServeRAID card and install the latest firmware Clear the hard disks Set up the RAID array The next step is format the NOS partition. I select my partition size and the utility goes through the following steps: Creating NOS partition Formatting NOS partition (NTFS) Copying W32 files The copying W32 files takes about 10 minutes. I see the CD drive and disks working hard. When the copying is complete, I'm taken to a blank page just NOS Partitioning at the top. At the bottom of the screen are the familiar Back and Exit buttons. I see the place where the Next button should be, and if I click on it I can tell there is something there, but the space is empty. No button is displayed and clicking the empty spot doesn't ever take me to the next screen. I can't load the OS until I get past this part. I have already tried: Burning multiple copies and versions of the ServerGuide CD Letting the final screen just sit there over the weekend thinking it might advance after syncing the drives or something Has anybody else seen this? I'm really at a loss here.

    Read the article

  • Does a 3ware "ECC-ERROR" matter on a JBOD when I have ZFS?

    - by Stefan Lasiewski
    I have a FreeBSD 8.x machine running ZFS and with a 3ware 9690SA controller. The 3ware controller shows an ECC-ERROR with one of the disks: //host> /c0 show VPort Status Unit Size Type Phy Encl-Slot Model ------------------------------------------------------------------------------ p0 OK u0 279.39 GB SAS 0 - SEAGATE ST3300657SS p1 OK u0 279.39 GB SAS 1 - SEAGATE ST3300657SS p2 OK u1 931.51 GB SAS 2 - SEAGATE ST31000640SS p3 ECC-ERROR u2 931.51 GB SAS 3 - SEAGATE ST31000640SS p4 OK u3 931.51 GB SAS 4 - SEAGATE ST31000640SS /c0 show events shows no ECC errors in it's recent history. ZFS does not currently detect any errors. zpool status says No known data errors My question: Is this ECC-ERROR something that I need to be concerned about? According to the 3ware CLI 9.5.2 Manual, an ECC-ERROR means that the 3ware controller caught a read-error for one or more sectors on this drive. This sometimes occurs when a RAID array is recovering from a failed disk. I believe that ECC-ERRORS can also be detected when the 3ware Controller verifies each disk. None of the drives have failed and thus there was no drive rebuild, so I assume that 3ware discovered a bad sector when it ran it's weekly auto-verify scan of the disks. Is this a safe assumption? According to our logs, ZFS has not detected any bad sectors on this drive. ZFS can work around read errors -- if ZFS detects a bad sector on the drive, it will simply mark that sector as bad and never use it again. From the ZFS perspective one bad sector isn't a big deal, although it might indicate that the drive is starting to go bad.

    Read the article

  • How to let hard drive sleep in RAID1 configuration?

    - by Al Kepp
    Normally in Windows 7 a hard drive stops spinning when it is not used for a longer while. This can be configured in Windows and I use it on computers which are turned on 24/7 but not used much often. My problem is on a computer with Intel X79 chipset with an integrated RAID controller. There is Windows 7 installed on an SSD drive, and there is RAID1 array with two SATA HDD drives for data. Those SATA drives aren't used much so I'd like to let them sleep (i.e stop spinning). But they ignore settings in Windows. How to let them sleep when using RAID1? It seems to me that those drives are "unstoppable", they are spinning 24/7 even when they aren't used at all. Maybe they would behave normally if I used Windows-based software RAID, but I use hardware RAID controller. Is there a way to let them stop spinning and sleep after for example 3 or 5 hours of inactivity (i.e. the same way as they would behave in Windows without RAID)?

    Read the article

  • Using smartctl to get vendor specific Attributes from ssd drive behind a SmartArray P410 controller

    - by Lairsdragon
    Recently I have deployed some HP server with SSD's behind a SmartArray P410 controller. While not official supported from HP the server work well sofar. Now I like to get wear level info's, error statistics etc from the drive. While the SA P410 supports a passthru of the SMART Command to a single drive in the array the output I was not able to the the interesting things from the drive. In this case especially the value the Wear level indicator is from interest for me (Attr.ID 233), but this is ony present if the drive is directly attanched to a SATA Controller. smartctl on directly connected ssd: # smartctl -A /dev/sda smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF READ SMART DATA SECTION === SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 3 Spin_Up_Time 0x0000 100 000 000 Old_age Offline In_the_past 0 4 Start_Stop_Count 0x0000 100 000 000 Old_age Offline In_the_past 0 5 Reallocated_Sector_Ct 0x0002 100 100 000 Old_age Always - 0 9 Power_On_Hours 0x0002 100 100 000 Old_age Always - 8561 12 Power_Cycle_Count 0x0002 100 100 000 Old_age Always - 55 192 Power-Off_Retract_Count 0x0002 100 100 000 Old_age Always - 29 232 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 0 233 Unknown_Attribute 0x0002 088 088 000 Old_age Always - 0 225 Load_Cycle_Count 0x0000 198 198 000 Old_age Offline - 508509 226 Load-in_Time 0x0002 255 000 000 Old_age Always In_the_past 0 227 Torq-amp_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 228 Power-off_Retract_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 smartctl on P410 connected ssd: # ./smartctl -A -d cciss,0 /dev/cciss/c1d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net (Right, it is complety empty) smartctl on P410 connected hdd: # ./smartctl -A -d cciss,0 /dev/cciss/c0d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Current Drive Temperature: 27 C Drive Trip Temperature: 68 C Vendor (Seagate) cache information Blocks sent to initiator = 1871654030 Blocks received from initiator = 1360012929 Blocks read from cache and sent to initiator = 2178203797 Number of read and write commands whose size <= segment size = 46052239 Number of read and write commands whose size > segment size = 0 Vendor (Seagate/Hitachi) factory information number of hours powered up = 3363.25 number of minutes until next internal SMART test = 12 Do I hunt here a bug, or is this a limitation of the p410 SMART cmd Passthru?

    Read the article

  • Very poor SCSI hd performance on IBM x336 with LSI 1030 RAID1

    - by David Tschoepe
    I'm experiencing very poor performance on an IBM x336 server with dual 73GB 15k hard drives on a U320 controller, LSI 1030. We're getting maybe 3.5MB/sec max (per HD Tune utility). It should be over 100MB/sec at least, I would think (another x335 box is running 70-80MB/sec). The server was recently setup and didn't really notice the problem, but may have been there from the beginning, so not sure. I have installed the IBM ServerRAID Windows utility. The server is running Windows 2008 R2 Web edition (if that matters). I thought maybe one of the drives was bad, so far I have removed one of the drives out of the array and tested again, but still the same results. I'm waiting for the RAID1 to resync and I will try pulling the other drive next. I've also used the ServerRAID utility but haven't noticed anything in there that might indicate a problem. Not sure if I'm on the right path here. So looking for some advice to track this down.

    Read the article

  • Disk IO slow on ESXi, even slower on a VM (freeNAS + iSCSI)

    - by varesa
    I have a server with ESXi 5 and iSCSI attached network storage(4x1Tb Raid-Z on freenas 8.0.4). Those two machines are connected to each other with Gigabit ethernet. The raid-z volume is divided into three parts: two zvols, shared with iscsi, and one directly on top of zfs, shared with nfs and similar. I ssh'd into the freeNAS box, and did some testing on the disks. I used ddto test the third part of the disks (straight on top of ZFS). I copied a 4GB (2x the amount of RAM) block from /dev/zero to the disk, and the speed was 80MB/s. Other of the iSCSI shared zvols is a datastore for the ESXi. I did similar test with time dd .. there. Since the dd there did not give the speed, I divided the amount of data transfered by the time show by time. The result was around 30-40 MB/s. Thats about half of the speed from the freeNAS host! Then I tested the IO on a VM running on the same ESXi host. The VM was a light CentOS 6.0 machine, which was not really doing anything else at that time. There were no other VMs running on the server at the time, and the other two "parts" of the disk array were not used. A similar dd test gave me result of about 15-20 MB/s. That is again about half of the result on a lower level! Of course the is some overhead in raid-z - zfs - zvolume - iSCSI - VMFS - VM, but I don't expect it to be that big. I belive there must be something wrong in my system. I have heard about bad performance of freeNAS's iSCSI, is that it? I have not managed to get any other "big" SAN OS to run on the box (NexentaSTOR, openfiler). Can you see any obvious problems with my setup?

    Read the article

  • RabbitMQ message consumers stop consuming messages

    - by Bruno Thomas
    Hi server fault, Our team is in a spike sprint to choose between ActiveMQ or RabbitMQ. We made 2 little producer/consumer spikes sending an object message with an array of 16 strings, a timestamp, and 2 integers. The spikes are ok on our devs machines (messages are well consumed). Then came the benchs. We first noticed that somtimes, on our machines, when we were sending a lot of messages the consumer was sometimes hanging. It was there, but the messsages were accumulating in the queue. When we went on the bench plateform : cluster of 2 rabbitmq machines 4 cores/3.2Ghz, 4Gb RAM, load balanced by a VIP one to 6 consumers running on the rabbitmq machines, saving the messages in a mysql DB (same type of machine for the DB) 12 producers running on 12 AS machines (tomcat), attacked with jmeter running on another machine. The load is about 600 to 700 http request per second, on the servlets that produces the same load of RabbitMQ messages. We noticed that sometimes, consumers hang (well, they are not blocked, but they dont consume messages anymore). We can see that because each consumer save around 100 msg/sec in database, so when one is stopping consumming, the overall messages saved per seconds in DB fall down with the same ratio (if let say 3 consumers stop, we fall around 600 msg/sec to 300 msg/sec). During that time, the producers are ok, and still produce at the jmeter rate (around 600 msg/sec). The messages are in the queues and taken by the consumers still "alive". We load all the servlets with the producers first, then launch all the consumers one by one, checking if the connexions are ok, then run jmeter. We are sending messages to one direct exchange. All consumers are listening to one persistent queue bounded to the exchange. That point is major for our choice. Have you seen this with rabbitmq, do you have an idea of what is going on ? Thank you for your answers.

    Read the article

  • Is it possible to have a wireless in-house NAS with wireless data transfer rates of equivalent to SATA speeds?

    - by techaddict
    Basically I would like to know, if it is possible to set up an NAS in my house to be accessed wirelessly, that can reach equivalent real-life data transfer speeds to USB 3.0 or an internal SATA hard drive. I have been wanting to do this for some time ( a couple of years now). Basically, this is what I want to do: Plug in a number of hard drives in an array, somewhere in my house, to be left plugged in and never have to be monitored. Ideally several terabytes. Whenever I am home, to have my computer and laptop configured to automatically find the NAS, as easy as plugging in an external hard drive - except completely wirelessly. Data transfer needs to be as seamless and quick as having added another internal hard drive in my laptop. Moreover, data should be able to accessed without having to copy it over - I should be able to wirelessly access the NAS and browse files, and open files directly from the NAS. For example, say I wanted to open a video - I should be able to play the video that is located on the NAS, directly from the NAS, completely wirelessly. If I wanted to open a .pdf file, I should be able to open it and read it directly from the NAS, as if it were located on my physical internal hard drive. Cost is important as well. Please tell me what equipment I need for this to be possible. I know you geniuses out there who can tell me if this is possible.

    Read the article

  • Outlook 2007/2010 autodiscovering old Exchange info

    - by Dan
    I currently have an Exchange setup as follows: two Exchange 2003 servers clustered together set up as the current mailbox stores, one Exchange 2003 setup as a frontend, one Exchange 2007 set up as a frontend (was set up for testing by my predecessor, never really used intentionally), and now four Exchange 2010 servers - two mailboxes in a DAG and two with Hub/CAS. Everything seems to be working fine with one exception - Outlook 2007/2010 clients are still autodiscovering the test 2007 frontend and not the 2010 CAS array. I know this because there's an expired cert on the 2007 box so the client displays a cert error when you attempt to autocreate the outlook profile. From what I've read, there is an SCP (Service Connection Point) in AD that is pointing to the old server and it is getting returned first, causing Outlook to try it first. How can I prevent Outlook from even attempting to connect to this 2007 box from now on? http://www.msexchange.org/articles_tutorials/exchange-server-2010/management-administration/exchange-autodiscover.html When Outlook 2007 is installed on a domain joined workstation then the Outlook client will query Active Directory for the Autodiscover information. Active Directory will return a list of SCP’s and the Outlook client will automatically select the first SCP in this list. Using the information found in the SCP the Outlook client will contact the Client Access Server for its configuration information and the Outlook client will be configured automatically.

    Read the article

  • Why are SMART error rates going down?

    - by Jeff Shattock
    I have a hard drive that's part of a Linux software raid5 array. SMART has reported that its multi_zone_error_rate was 0, then 1, then 3. So I figured I better start backing up more frequently and prepare to replace the drive. Now, today, the multi_zone_error_rate of that very same drive is back down to 1. It seems that 2 errors unhappened while I wasn't looking. I've also seen simliar behaviour by inspecting the syslog on the server. Jun 7 21:01:17 FS1 smartd[25593]: Device: /dev/sdc, SMART Usage Attribute: 7 Seek_Error_Rate changed from 200 to 100 Jun 7 21:01:17 FS1 smartd[25593]: Device: /dev/sde, SMART Usage Attribute: 7 Seek_Error_Rate changed from 200 to 100 Jun 7 21:01:18 FS1 smartd[25593]: Device: /dev/sdg, SMART Usage Attribute: 7 Seek_Error_Rate changed from 200 to 100 Jun 8 02:31:18 FS1 smartd[25593]: Device: /dev/sdg, SMART Usage Attribute: 7 Seek_Error_Rate changed from 100 to 200 Jun 8 03:01:17 FS1 smartd[25593]: Device: /dev/sdc, SMART Usage Attribute: 7 Seek_Error_Rate changed from 100 to 200 Jun 8 03:01:17 FS1 smartd[25593]: Device: /dev/sde, SMART Usage Attribute: 7 Seek_Error_Rate changed from 100 to 200 These are raw values, not the human-useful values that smartctl -a produces, but the behaviour is similar: error rates changing, then undoing the change. None of these are the drive that had the multi_zone weirdness. I haven't seen any problems from the RAID; its most recent scrub ( < 24 hours ago) came back totally clean. The only thing I can think of is that the SMART reporting circuitry on the drive isn't working properly all the time. The cables are in tight on the drive and board. What's going on here?

    Read the article

  • Chrome caching 302 redirects

    - by Thermionix
    I have a php script with is used to rotate banner images on a site. Under Firefox/IE page refreshes will make another request and a different image will be returned. Under Chrome, the request seems to be cached and only opening the page in a new tab will cause it to actually query the script. I believe this used to work in older versions of chrome, I've tried a few different types of redirect codes all with the same result. Any tips? <img class="banner" src="/inc/banner.php" alt=""> ~$ cat /var/www/inc/banner.php <?php header("HTTP/1.1 302 Redirect"); header("Cache-Control: max-age=0, no-cache, no-store, must-revalidate"); //header('HTTP/1.1 307 Temporary Redirect'); //header("expires: none"); //header("expires: max"); //header("Cache-Control: public"); $folder = '../img/banner/'; $exts = 'jpg jpeg png gif'; $files = array(); $i = -1; if ('' == $folder) $folder = './'; $handle = opendir($folder); $exts = explode(' ', $exts); while (false !== ($file = readdir($handle))) { foreach($exts as $ext) { // for each extension check the extension if (preg_match('/\.'.$ext.'$/i', $file, $test)) { // faster than ereg, case insensitive $files[] = $file; // it's good ++$i; } } } closedir($handle); // We're not using it anymore mt_srand((double)microtime()*1000000); // seed for PHP < 4.2 $rand = mt_rand(0, $i); // $i was incremented as we went along header('Location: '.$folder.$files[$rand]); flush(); ?> curl output; ~$ curl -I -k https://example.net/inc/banner.php HTTP/1.1 302 Redirect Server: nginx/1.1.14 Date: Fri, 24 Feb 2012 03:23:46 GMT Content-Type: text/html Connection: keep-alive X-Powered-By: PHP/5.3.10-1ubuntu1 Cache-Control: max-age=0, no-cache, no-store, must-revalidate Location: ../img/banner/2.jpg

    Read the article

  • Is current SATA 6 gb/s equipment simply unreliable?

    - by korkman
    I have a 45-disk array of Seagate Barracuda 3 TB ST3000DM001 (yes these are desktop drives I'm aware of that) in a Supermicro sc847 JBOD, connected via LSI 9285. I have found a solution for the problem description below by reducing speed via MegaCli -PhySetLinkSpeed -phy0 2 -a0; for i in $(seq 48); do MegaCli -PhySetLinkSpeed -phy${i} 2 -a0; done and rebooting. The question remains: Is this typical for current 6 gb/s equipment? Is this the sad state of SATA storage? Or is some of my equipment (the sff-8088 cables come to mind) bad? The Problem was: Synchronizing HW RAID-6, disks kept offlining. Fetching SMART values reveiled that those which offlined did not increase powered-on hours anymore. That is, their firmware (CC4C) seems to crash. Digging into the matter by switching to Software RAID-6, with the disks passed-through, I got tons of kernel messages scattered across all disks, with 6 gb/s: sd 0:0:9:0: [sdb] Sense Key : No Sense [current] Info fld=0x0 sd 0:0:9:0: [sdb] Add. Sense: No additional sense information And finally, when a disk offlines: megasas: [ 5]waiting for 160 commands to complete ... megasas: [35]waiting for 159 commands to complete ... megasas: [155]waiting for 156 commands to complete ... megaraid_sas: pending commands remain after waiting, will reset adapter. Ugly controller reset here, then minutes later: megaraid_sas: Reset successful. sd 0:0:28:0: Device offlined - not ready after error recovery ... sd 0:0:28:0: [sdu] Unhandled error code sd 0:0:28:0: [sdu] Result: hostbyte=DID_ERROR driverbyte=DRIVER_OK sd 0:0:28:0: [sdu] CDB: Read(10): 28 00 23 21 2f 40 00 00 70 00 sd 0:0:28:0: [sdu] killing request Reduced speed to 3 gb/s like written above, all problems vanished.

    Read the article

  • Windows Server 2008 backup VHD's - is it possible to mount/open in Windows 7?

    - by Simon
    Hi All, Is it possible to mount the VHD files created by the Windows Server 2008 backup utility onto a Windows 7 (release) client? Following an array failure I was very worried that there was a problem with both the backup sets on different USB drives as attaching the VHD to a Win 7 box did not show the expected structure (instead they behaved like unformatted disk space). Subsequently, I've attached the backup drive to a 2008r2 machine that I'd intended to be the replacement and the backup set can be browsed without issue (seemingly). When the new disks arrive I'll go through the recovery process and see where we are, but it looks promising so far. Is it simply the case that you can't take server created VHD's and mount them on desktop machines? (Rather than hyper-ventilating at the thought of years of lost photos and email, I'm now just mildly curious) Edit:One thing that has confused things is that the backup utility on Win7 is more restrictive about restoring from external devices than the equivilent on 2008r2. With r2, I can restore files 'from another server' and browse to external storage. Win7 only allows the back to be located on a network share. Once my box of new disks arrive and I've got something to restore onto, I'll move the smaller of the backup VHDs onto network storage reachable by Win7 and see if the VHD is readable. I haven't read up on the VHD process used by the backup app - I'm assuming it's a base VHD and differencing files used for incremental backups and that the restore app understands this. Finally: In retrospect the question should have been, 'can I restore a 2008r2 backup set via a Win 7 client' Thanks

    Read the article

  • linux hardware raid 10 / lvm / virtual machine partition alignment and filesystem optimization

    - by Jason Ward
    I've been reading everything I can find about partition alignment and filesystem optimization (ext4 and xfs) but still don't know enough to be confident in setting up my current configuration. My remaining confusion comes from the LVM layer and if I should use raid parameters on the filesystem in guest os'es. My main questions are: When I use 'pvcreate --dataalignment' do I use the stripe-width as calculated for a filesystem on RAID (128kB for ext4 in my situation), the Stripe size of the RAID set (256kB), something else altogether, or do I not need this? When I create ext2/3/4 or xfs filesystems in guests on the Logical Volumes, should I add the settings for the underlying RAID (e.g. mkfs.ext4 -b 4096 -E stride=64,stripe-width=128)? Does anyone see any glaring errors in my set up below? I'm running some benchmarks now but haven't done enough to start comparing results. I have four drives in RAID 10 on a 3ware 9750-4i controller (more details on the settings below) giving me a 6.0TB device at /dev/sda. Here is my partition table: Model: LSI 9750-4i DISK (scsi) Disk /dev/sda: 5722024MiB Sector size (logical/physical): 512B/512B Partition Table: gpt Number Start End Size File system Name Flags 1 1.00MiB 257MiB 256MiB ext4 BOOTPART boot 2 257MiB 4353MiB 4096MiB linux-swap(v1) 3 4353MiB 266497MiB 262144MiB ext4 4 266497MiB 4460801MiB 4194304MiB Partition 1 is to be the /boot partition for my xen host. Partition 2 is swap. Partition 3 is to be the root (/) for my xen host. Partition 4 is to be (the only) physical volume to be used by LVM (for those who are counting, I left about 1.2TB unallocated for now) For my Xen guests, I usually create a Logical Volume of the needed size and present it to the guests for them to partition as needed. I know there are other ways of handling that but this method works best for my situation. Here's the hardware of interest on my CentOS 6.3 Xen Host: 4x Seagate Barracuda 3TB ST3000DM001 Drives (sector size: 512 logical/4096 physical) 3ware 9750-4i w/BBU (sector size reported: 512 logical/512 physical) All four drives make up a RAID 10 array. Stripe: 256kB Write Cache enabled Read Cache: intelligent StoreSave: Balance Thanks!

    Read the article

  • Four disks - RAID 10 or two mirrored pairs?

    - by ewwhite
    I have this discussion with developers quite often. The context is an application running in Linux that has a medium amount of disk I/O. The servers are HP ProLiant DL3x0 G6 with four disks of equal size @ 15k rpm, backed with a P410 controller and 512MB of battery or flash-based cache. There are two schools of thought here, and I wanted some feedback... 1). I'm of the mind that it makes sense to create an array containing all four disks set up in a RAID 10 (1+0) and partition as necessary. This gives the greatest headroom for growth, has the benefit of leveraging the higher spindle count and better fault-tolerance without degradation. 2). The developers think that it's better to have multiple RAID 1 pairs. One for the OS and one for the application data, citing that the spindle separation would reduce resource contention. However, this limits throughput by halving the number of drives and in this case, the OS doesn't really do much other than regular system logging. Additionally, the fact that we have the battery RAID cache and substantial RAM seems to negate the impact of disk latency... What are your thoughts?

    Read the article

  • Virtual Fileserver

    - by Sergei
    Hi, We are planning to move our production servers to the datacenter and virtualize remaining servers in the process.Datacenter will have HP blades with vSphere on top.Currentliy we are using Celerra NS20 as fileserver.Since datacenter is using HP kit and EVA 4400 as SAN, we cannot have Celerra there, as EMC supoprt for Celerra does not work for non EMC array. I have searched for possible options and one of them was to have HP NAS blade X3800sb instead of Celerra.However this seems like overkill for me.We are only using Celerra for about 100 users and 50 servers and I think having X3800sb could be waste of resources. The other option would be to have a virtual fileserver as a part of vmware environment in datacenter.We only need CIFS to be provided.The only option I can think of is Windows Storage server.We had a bad expirience with Windows servers used as fileservers ( memory leaks one thing) in the past and this was one of the reasons we moved to Celerra. What are the other options?We need something as reliable as Celerra with as many options as possible.For example , Celerra has per folder quotas, deduplication, dynamic volume allocation, automatic failover, VTLU, replication. Also we would need to replicate NAS data to the failover site.We could use block level replication , SAN-to-SAN, but this would mean wasted bandwidth, as we need only subset of folders to be replicated.We used CA XSoft for windows servers in the past and Celerra has option for Celerra replication. Thank you very much in advance, Please ask me if I missed any details!

    Read the article

  • Excel concatenate strings from cells listed in third cell

    - by Puddingfox
    I have an excel 2007 workbook that has five columns: A. A list of machines B. A list of service numbers for each machine C. A list of service names for each machine ...(nothing here) I. A list of Service Numbers J. A list of Service Names Each machine listed in column A has one or more services running on it from the list in column J. I would like to be able to add services to a machine (i.e. updating the cell in Column C) by simply adding another comma-separated number to Column B. For Example, The first row would look like this assuming Machine1 has the first three services: | A | B | C | Machine1 | 1,2,3 | HTTP,HTTPS,DNS Right now I have to manually update the formula in column c for each change I make. The current formula is: =CONCATENATE(J1,",",J2,",",J3) I would like to use something like this (please forgive my syntax; I'm a coder and I'm treating cell B1 as if it is an indexed array): =CONCATENATE(CELL("J"+B1[0] , "," , "J"+B1[1] , "," "J"+B1[2]) Although having variable numbers of services makes this even more difficult. Is there any way of doing this. For reference, this is columns I and J: | I | J | 1 |HTTP | 2 |HTTPS | 3 |DNS ..... | 16 |Service16 I don't know very much about Excel so any help is greatly appreciated.

    Read the article

  • when should be choose simple php mail and when smpt with loggin+password?

    - by user43353
    Hi, My Case: web application that need to send 1,000 messages per day to main gmail account. (Only need to send email, not need receive emails - email client) 1. option - use php mail function + sendmail + config php.ini php example: <?php $to = '[email protected]'; $subject = 'the subject'; $message = 'hello'; $headers = 'From: [email protected]' . "\r\n" . 'Reply-To: [email protected]' . "\r\n" . 'X-Mailer: PHP/' . phpversion(); mail($to, $subject, $message, $headers); ?> php.ini config (ubuntu): sendmail_path = /usr/sbin/sendmail -t -i pros:don't need email account, easy to setup cons:? 2. option - use Zend_Mail + transport on smpt+ password auto php example(need include Zend_Mail classes): $config = array('auth' => 'login', 'username' => 'myusername', 'password' => 'password'); $transport = new Zend_Mail_Transport_Smtp('mail.server.com', $config); $mail = new Zend_Mail(); $mail->setBodyText('This is the text of the mail.'); $mail->setFrom('[email protected]', 'Some Sender'); $mail->addTo('[email protected]', 'Some Recipient'); $mail->setSubject('TestSubject'); $mail->send($transport); pros:? cons:? Questions: Can 1 option be filtered by gmail email server as spam? please can you add pros + cons to options above Thanks

    Read the article

  • Looking to replace Ghost with FSArchiver or Clonezilla, few questions about capabilities

    - by Daniel Wright
    I work for a PC Repair company and we are looking into setting up a dedicated machine with externally accessible SATA bays to clone harddrives as a safety net incase something goes wrong during a repair. We currently use a SATA/PATA to USB bridge called MagicBridge and Norton Ghost on any workstation, but we're looking to move away from Ghost. We have a computer with a large RAID5 array with Windows Server 2008 Standard currently installed, but this can be replaced with a flavour of *nix. I have some experience with Clonezilla, but FSArchiver also seems like a suitable replacment too. My Head Technician wants to know if my chosen solution (probably Clonezilla or FSArchiver, but I'm open to free suggestions) is capable of: Cloning a degraded RAID, such as a single drive from a RAID1 mirror without complaining Producing images that are easily mountable (he'd prefer them to be mountable in Windows, but if there is no other easy way, *nix should be fine) akin to Ghost Explorer so individual files can be restored as well as being able to do bare metal restores. My apologies for wordiness but I wanted to be thorough in my explaination. Thanks for any suggestions or tips :) EDIT: I've just found out that Clonezilla has a workaround for cloning RADI1 drives EDIT2: Found the answer to both of my questions, aparently I wasn't phrasing my searches right, could this question be deleted please?

    Read the article

  • Compiling PHP with GD and libjpeg support

    - by Robin Winslow
    I compile my own PHP, partly to learn more about how PHP is put together, and partly because I'm always finding I need modules that aren't available by default, and this way I have control over that. My problem is that I can't get JPEG support in PHP. Using CentOS 5.6. Here are my configuration options when compiling PHP 5.3.8: './configure' '--enable-fpm' '--enable-mbstring' '--with-mysql' '--with-mysqli' '--with-gd' '--with-curl' '--with-mcrypt' '--with-zlib' '--with-pear' '--with-gmp' '--with-xsl' '--enable-zip' '--disable-fileinfo' '--with-jpeg-dir=/usr/lib/' The ./configure output says: checking for GD support... yes checking for the location of libjpeg... no checking for the location of libpng... no checking for the location of libXpm... no And then we can see that GD is installed, but that JPEG support isn't there: # php -r 'print_r(gd_info());' Array ( [GD Version] => bundled (2.0.34 compatible) [FreeType Support] => [T1Lib Support] => [GIF Read Support] => 1 [GIF Create Support] => 1 [JPEG Support] => [PNG Support] => 1 [WBMP Support] => 1 [XPM Support] => [XBM Support] => 1 [JIS-mapped Japanese Font Support] => ) I know that PHP needs to be able to find libjpeg, and it obviously can't find a version it's happy with. I would have thought /usr/lib/libjpeg.so or /usr/lib/libjpeg.so.62 would be what it needs, but I supplied it with the correct lib directory (--with-jpeg-dir=/usr/lib/) and it doesn't pick them up so I guess they can't be the right versions. rpm says libjpeg is installed. Should I yum remove and reinstall it, and all it's dependent packages? Might that fix the problem? Here's a paste bin with a collection of hopefully useful system information: http://pastebin.com/ied0kPR6

    Read the article

  • Is UPS worthwhile for home equipment?

    - by Jon Skeet
    Over the years, I've had to throw away a quite a few bits of computing equipment (and the like): Several ADSL routers with odd symptoms (losing wireless connections, losing wired connections, DHCP failures, DNS symptoms etc) Two PVRs spontaneously rebooting and corrupting themselves (despite the best efforts of the community to diagnose and help) One external hard disk still claiming to function, but corrupting data One hard disk as part of a NAS raid array "going bad" (as far as the NAS was concerned) (This is in addition to various laptops and printers dying in ways unrelated to this question.) Obviously it'll be impossible to tell for sure from such a small amount of information, but might these be related to power issues? I don't currently have a UPS for any of this equipment. Everything on surge-protected gang sockets, but there's nothing to smooth a power cut. Is home UPS really viable and useful? I know there are some reasonably cheap UPSes on the market, but I don't know how useful they really are. I'm not interested in keeping my home network actually running during a power cut, but I'd like it to power down a bit more gracefully if the current situation is putting my hardware in jeopardy.

    Read the article

< Previous Page | 491 492 493 494 495 496 497 498 499 500 501 502  | Next Page >