Search Results

Search found 371 results on 15 pages for 'createobject'.

Page 5/15 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • Execute Stored Procedure from Classic ASP

    - by Jaco Pretorius
    For some fantastic reason I find myself debugging a problem in a Classic ASP page (at least 10 years of my life lost in the last 2 days). I'm trying to execute a stored procedure which contains some OUT parameters. The problem is that one of the OUT parameters is not being populated when the stored procedure returns. I can execute the stored proc from SQL management studio (this is 2008) and all the values are being set and returned exactly as expected. declare @inVar1 varchar(255) declare @inVar2 varchar(255) declare @outVar1 varchar(255) declare @outVar2 varchar(255) SET @inVar2 = 'someValue' exec theStoredProc @inVar1 , @inVar2 , @outVar1 OUT, @outVar2 OUT print '@outVar1=' + @outVar1 print '@outVar2=' + @outVar2 Works great. Fantastic. Perfect. The exact values that I'm expecting are being returned and printed out. Right, since I'm trying to debug a Classic ASP page I copied the code into a VBScript file to try and narrow down the problem. Here is what I came up with: Set Conn = CreateObject("ADODB.Connection") Conn.Open "xxx" Set objCommandSec = CreateObject("ADODB.Command") objCommandSec.ActiveConnection = Conn objCommandSec.CommandType = 4 objCommandSec.CommandText = "theStoredProc " objCommandSec.Parameters.Refresh objCommandSec.Parameters(2) = "someValue" objCommandSec.Execute MsgBox(objCommandSec.Parameters(3)) Doesn't work. Not even a little bit. (Another ten years of my life down the drain) The third parameter is simply NULL - which is what I'm experiencing in the Classic ASP page as well. Could someone shed some light on this? Am I completely daft for thinking that the classic ASP code would be the same as the VBScript code? I think it's using the same scripting engine and syntax so I should be ok, but I'm not 100% sure. The result I'm seeing from my VBScript is the same as I'm seeing in ASP.

    Read the article

  • Vbscript - Checking each subfolder for files

    - by Kenny Bones
    Ok, this is a script that's supposed to basically mirror two sets of folders. I managed to get it to work, but it seems like it didn't check each subfolder. So, I added these lines to the code: Set colFolders = objFolder.Subfolders Then I added this: For each subFolder in colFolders For each objFile in colFiles Dim DateModified DateModified = objFile.DateLastModified ReplaceIfNewer objFile, DateModified, strSourceFolder, strDestFolder Next Next This however does not seem to be working. This is the full code below. Dim strSourceFolder, strDestFolder Dim fso, objFolder, colFiles, colfolders strSourceFolder = "c:\users\vegsan\desktop\Source\" strDestFolder = "c:\users\vegsan\desktop\Dest\" Set fso = CreateObject("Scripting.FileSystemObject") Set objFolder = fso.GetFolder(strSourceFolder) Set colFiles = objFolder.Files Set colFolders = objFolder.Subfolders For each subFolder in colFolders For each objFile in colFiles Dim DateModified DateModified = objFile.DateLastModified ReplaceIfNewer objFile, DateModified, strSourceFolder, strDestFolder Next Next Sub ReplaceIfNewer (sourceFile, DateModified, SourceFolder, DestFolder) Const OVERWRITE_EXISTING = True Dim fso, objFolder, colFiles, sourceFileName, destFileName Dim DestDateModified, objDestFile Set fso = CreateObject("Scripting.FileSystemObject") sourceFileName = fso.GetFileName(sourceFile) destFileName = DestFolder & sourceFileName if fso.FileExists(destFileName) Then Set objDestFile = fso.GetFile(destFileName) DestDateModified = objDestFile.DateLastModified if DateModified <> DestDateModified Then fso.CopyFile sourceFile, destFileName End if End if if Not fso.FileExists(destFileName) Then fso.CopyFile sourceFile, destFileName End if End Sub

    Read the article

  • asp code for upload data

    - by vicky
    hello everyone i have this code for uploading an excel file and save the data into database.I m not able to write the code for database entry. someone please help <% if (Request("FileName") <> "") Then Dim objUpload, lngLoop Response.Write(server.MapPath(".")) If Request.TotalBytes > 0 Then Set objUpload = New vbsUpload For lngLoop = 0 to objUpload.Files.Count - 1 'If accessing this page annonymously, 'the internet guest account must have 'write permission to the path below. objUpload.Files.Item(lngLoop).Save "D:\PrismUpdated\prism_latest\Prism\uploadxl\" Response.Write "File Uploaded" Next Dim FSYSObj, folderObj, process_folder process_folder = server.MapPath(".") & "\uploadxl" set FSYSObj = server.CreateObject("Scripting.FileSystemObject") set folderObj = FSYSObj.GetFolder(process_folder) set filCollection = folderObj.Files Dim SQLStr SQLStr = "INSERT ALL INTO TABLENAME " for each file in filCollection file_name = file.name path = folderObj & "\" & file_name Set objExcel_chk = CreateObject("Excel.Application") Set ws1 = objExcel_chk.Workbooks.Open(path).Sheets(1) row_cnt = 1 'for row_cnt = 6 to 7 ' if ws1.Cells(row_cnt,col_cnt).Value <> "" then ' col = col_cnt ' end if 'next While (ws1.Cells(row_cnt, 1).Value <> "") for col_cnt = 1 to 10 SQLStr = SQLStr & "VALUES('" & ws1.Cells(row_cnt, 1).Value & "')" next row_cnt = row_cnt + 1 WEnd 'objExcel_chk.Quit objExcel_chk.Workbooks.Close() set ws1 = nothing objExcel_chk.Quit Response.Write(SQLStr) 'set filobj = FSYSObj.GetFile (sub_fol_path & "\" & file_name) 'filobj.Delete next End if End If plz tell me how to save the following excel data to the oracle databse.any help would be appreciated

    Read the article

  • Is anyone familiar with SDPT.clsSDPT?

    - by David Stratton
    Normally I wouldn't ask this kind of question here, but I'm desperate at this point. I'm attempting to support a classic ASP app written by a predecessor who is no longer available. Keeping it short, several applications use a dll to perform encryption of sensitive data. This dll is named SDPT.dll, and the line of code used to create an object is set objSDPT = server.CreateObject("SDPT.clsSDPT") At this point, I am getting errors in a critical app on one of my servers, and I've actually hit a dead end. The error is a standard "Server.CreateObject Failed" message, which I know how to troubleshoot in most cases. However, in this case, all of my normal tries, plus several hours of Google searches are coming up with nothing that works. At this point, I'm not so much looking for help in troubleshooting the issue as I am in finding any sort of reference on this third party component. Even finding that is proving to be difficult, so I'm resorting to asking any of the seasoned developers that hang out here if they are familiar with this product, who it was developed by, and if any documentation on it exists anywhere.

    Read the article

  • Have you had DLL's fail after upgrading to 64 bit server?

    - by quakkels
    Hey All, I'm wondering if anyone else has experienced failed DLL's after upgrading their servers. My company is in the process of upgrading our code and server's after ten years of using classic ASP. We've set up our new server running Windows 2008 and IIS 7. Our classic ASP code and our new asp.net mvc code work pretty well. Our problems started happening when we began moving our old websites to the new server. When trying to load the page on the actual server machine's browser, we initially got a 500 error. If we refreshed the page then some of the page would load but then display an error: Server object error 'ASP 0177 : 800401f3' Server.CreateObject Failed /folder/scriptname.asp, line 24 800401f3 btw: On remote machines we would just get 500 errors. Line 24 is the first executable code in the script: '23 lines of comments set A0SQL_DATA = server.createobject("olddllname.Data") 'the rest of the script That specific line is trying to use a ten year old DLL to create a server object. I don't think the server configuration is a problem because I'm able to create "adodb.recordset" server objects without any problems. Is there an issue when running correctly registered old DLL's on 64 bit systems? Is there a way to get old DLL's working on 64 bit systems?

    Read the article

  • VB .NET error handling, pass error to caller

    - by user1375452
    this is my very first project on vb.net and i am now struggling to migrate a vba working add in to a vb.net COM Add-in. I think i'm sort of getting the hang, but error handling has me stymied. This is a test i've been using to understand the try-catch and how to pass exception to caller Public Sub test() Dim ActWkSh As Excel.Worksheet Dim ActRng As Excel.Range Dim ActCll As Excel.Range Dim sVar01 As String Dim iVar01 As Integer Dim sVar02 As String Dim iVar02 As Integer Dim objVar01 As Object ActWkSh = Me.Application.ActiveSheet ActRng = Me.Application.Selection ActCll = Me.Application.ActiveCell iVar01 = iVar02 = 1 sVar01 = CStr(ActCll.Value) sVar02 = CStr(ActCll.Offset(1, 0).Value) Try objVar01 = GetValuesV(sVar01, sVar02) 'DO SOMETHING HERE Catch ex As Exception MsgBox("ERRORE: " + ex.Message) 'LOG ERROR SOMEWHERE Finally MsgBox("DONE!") End Try End Sub Private Function GetValuesV(ByVal QryStr As Object, ByVal qryConn As String) As Object Dim cnn As Object Dim rs As Object Try cnn = CreateObject("ADODB.Connection") cnn.Open(qryConn) rs = CreateObject("ADODB.recordset") rs = cnn.Execute(QryStr) If rs.EOF = False Then GetValuesV = rs.GetRows Else Throw New System.Exception("Query Return Empty Set") End If Catch ex As Exception Throw ex Finally rs.Close() cnn.Close() End Try End Function i'd like to have the error message up to test, but MsgBox("ERRORE: " + ex.Message) pops out something unexpected (Object variable or With block variable not set) What am i doing wrong here?? Thanks D

    Read the article

  • Copy folder contents using VBScript

    - by LukeR
    I am trying to copy the contents of certain folders to another folder using VBScript. The goal is to enumerate a user's AD groups and then copy specific folder content based on those groups. I have code, which is currently not working. Dim Group,User,objFSO,objFolder,source,target,StrDomain StrDomain = "domain.local" FolderBase = "\\domain.local\netlogon\workgrps\icons" Set net = CreateObject("wscript.network") Struser = net.username target = "\\fs1\users\"&net.username&"\Desktop\AppIcons\" DispUserInWhichGroup() Function DispUserInWhichGroup() On Error Resume Next Set objFSO=CreateObject("Scripting.FileSystemObject") Set User = GetObject("WinNT://" & strDomain & "/" & strUser & ",user") For Each Group In User.Groups source = FolderBase & Group.name Set objFolder = GetFolder(source) For Each file in objFolder.Files objFSO.CopyFile source &"\"& file.name, target&"\"&file.name Next Next End Function This has been cobbled together from various sources, and I'm sure most of it is right, I just can't get it working completely. Any assistance would be great. Cheers.

    Read the article

  • writing output to a dropdown list

    - by sushant
    <% dim req_id req_id=Request.Form("Req_id") Set conn=server.CreateObject("adodb.connection") conn.Open session("Psrconnect") Set rs=CreateObject("Adodb.Recordset") rs.Open "select * from releases where project like '%"&req_id&"%'", conn %> <SELECT style="LEFT: 454px; WIDTH: 500px; TOP: 413px" name="txtrelease1" id="txtrelease1"> <% if rs.EOF=true then %> <OPTION value="NO Request to Edit">No Request to Edit</OPTION> <% else do while rs.EOF<>true p=InStrRev(rs.Fields(0),"\") q=Len(rs.Fields(0)) r=(Right(rs.Fields(0),(q-p))) %> <OPTION value=<%=rs.Fields(0)%>> r </OPTION> <% rs.movenext loop end if %> </SELECT> i want to right the value of r in the dropdown list. i dont know the syntax. as of now the drop down list shows "r" , not the value inside it. how to do it?

    Read the article

  • Reordering columns (fields) in a ADO Recordset

    - by Sukotto
    I have a classic asp webpage written in vbscript that outputs the results from a third-party stored procedure. My user wants the page to display the columns of data in a different order than they come in from the database. Is there an easy and safe way to re-order the columns in an ADO recordset? I did not write this page and cannot change the SP. What is the minimum change I can make here to get the job done and not risk screwing up all the other stuff in the page? The code looks something like dim Conn, strSQL, RS Set Conn = Server.CreateObject("ADODB.Connection") Conn.Open ServerName Set strSQL = "EXEC storedProc @foo = " & Request("fooParam") 'This stored procedure returns a date column, an arbitrary ' ' number of data columns, and two summation columns. We ' ' want the two summation columns to move so they appear ' ' immediately after the data column ' Set RS = Server.CreateObject("ADODB.RecordSet") RS.ActiveConnection = Nothing RS.CursorLocation = adUseClient RS.CursorType = adOpenStatic RS.LockType = adLockBatchOptimistic RS.Open strSQL, Conn, adOpenDynamic, adLockOptimistic dim A ' ----- ' ' Insert some code here to move the columns of the RS around ' ' to suit the whim of my user ' ' ----- ' ' Several blocks of code that iterate over the RS and display it various ways ' RS.MoveFirst For A = 0 To RS.Fields.Count -1 ' do stuff ' Next ... RS.MoveFirst For A = 0 To RS.Fields.Count -1 ' do more stuff ' Next RS.Close : Set RS = Nothing Conn.Close : Set Conn = Nothing

    Read the article

  • Microsoft deployment toolkit 2010 failure message

    - by elhombre
    Hi all I am having a problem with the deployment of Windows 7 from a server with Microsoft Toolkit 2010. When deployment has finished I get a Windows error report which shows following message. FAILURE (Er): 70: CreateObject(Microsoft.BDD.Utility) - Permission denied Litetouch deployment failed, Return Code = - 2147023589 0x8007051B I don't get it what Microsoft.BDD.Utility is exactly and when this utility is used (Tasksequence?) ? Can anyone help me on this problem?

    Read the article

  • Error in VBScript http request

    - by Nate
    I asked this question here, but it turns out the issue is in our server configuration. The .vbs script has been reduced to the following: Dim http Set http = CreateObject("MSXML2.ServerXMLHTTP") http.Open "GET" , "http://google.com", False http.Send This triggers the same error message every time: msxml3.dll: A security problem occurred. The permissions on the .dll are set correctly, and nothing else should be preventing access to that file, so what could be causing the problem?

    Read the article

  • wait for the second VB script untill ended from primary VB script

    - by yael
    Hi I have VB script that run second VB script The second VB script ask some questions from the input box My problem is that “MyShell.Run” not wait until SecondVBscript.vbs will ended And the Other VB syntax run immodestly also Need to wait for MyShell.Run process ended and then perform the Other VB syntax How can I do that? Set MyShell = Wscript.CreateObject("WScript.Shell") MyShell.Run " C:\Program Files\SecondVBscript.vbs" Set MyShell = Nothing Other VB syntax

    Read the article

  • Remote installing an msi on citrix servers using WMI

    - by capn
    OK, I'm a C# programmer that is trying to streamline the deployment of a custom windows form app I inherited and built an installer for with WiX (this app will need to be reinstalled regularly as I'm making changes to it). I'm not really used to admin type things (or vbs, or WMI, or terminal servers, or Citrix, and even WiX and MSI are not things I usually deal with) but so far I put together some vbs and have an end goal in mind. The msi does work, and I've installed it from the mapped O: drive on my dev machine and while RDP'd to a citrix machine. End Goal: Deploy code written on my dev machine and compiled into an MSI (that I can improve upon within the confines of WiX and whatever the Windows Installer Engine allows) to the cluster of Citrix machines my users have access to. What am I missing in my script to get the MSI to execute on the remote machines? Layout: Machine A is my dev machine, and has the vbs script and the msi file (XP SP3) Machines C1 - C6 are the Citrix Servers that need the application installed them via the msi (Server 2003 R2 SP2) There is also optionally a shared network resource that all the machines can access. Script: 'Set WMI Constants Const wbemImpersonationLevelImpersonate = 3 Const wbemAuthenticationLevelPktPrivacy = 6 'Set whether this is installing to the debug Citrix Servers Const isDebug = true 'Set MSI location 'Network location yields error 1619 (This installation package could not be opened.) msiLocation = "\\255.255.255.255\odrive\Citrix Deployment\Setup.msi" 'Directory on machine A yields error 3 (file not found) 'msiLocation = "C:\Temp\Deploy\Setup.msi" 'Mapped network drive (on both machines) yield error 3 (file not found) 'msiLocation = "O:\Citrix Deployment\Setup.msi" 'Set login information strDomain = "MyDomain" Wscript.StdOut.Write "user name:" strUser = Wscript.StdIn.ReadLine Set objPassword = CreateObject("ScriptPW.Password") Wscript.StdOut.Write "password:" strPassword = objPassword.GetPassword() 'Names of Citrix Servers Dim citrixServerArray If isDebug Then citrixServerArray = array("C4") Else 'citrixServerArray = array("C1","C2","C3","C5","C6") End If 'Loop through each Citrix Server For Each citrixServer in citrixServerArray 'Login to remote computer Set objLocator = CreateObject("WbemScripting.SWbemLocator") Set objWMIService = objLocator.ConnectServer(citrixServer, _ "root\cimv2", _ strUser, _ strPassword, _ "MS_409", _ "ntlmdomain:" + strDomain) 'Set Remote Impersonation level objWMIService.Security_.ImpersonationLevel = wbemImpersonationLevelImpersonate objWMIService.Security_.AuthenticationLevel = wbemAuthenticationLevelPktPrivacy 'Reference to a process on the machine Dim objProcess : Set objProcess = objWMIService.Get("Win32_Process") 'Change user to install for terminal services errReturn = objProcess.Create _ ("cmd.exe /c change user /install", Null, Null, intProcessID) WScript.Echo errReturn 'Install MSI here 'Reference to a product on the machine Set objSoftware = objWMIService.Get("Win32_Product") 'All users set in option parameter, I'm led to believe that the third parameter is actually ignored 'http://www.webmasterkb.com/Uwe/Forum.aspx/vbscript/2433/Installing-programs-with-VbScript errReturn = objSoftware.Install(msiLocation,"ALLUSERS=2 REBOOT=ReallySuppress",True) Wscript.Echo errReturn 'Change user back to execute errReturn = objProcess.Create _ ("cmd.exe /c change user /execute", Null, Null, intProcessID) WScript.Echo errReturn Next I also tried using this to install, it doesn't return an error code, but doesn't install the msi either, and it makes me wonder if the change user /install command is even really working. errReturn = objProcess.Create _ ("cmd.exe /c msiexec /i ""O:\Citrix Deployment\Setup.msi"" /quiet") Wscript.Echo errReturn

    Read the article

  • Why won't my logon scripts map drives under Windows 7?

    - by Steven
    Why won't my logon scripts map drives under Windows 7? I'm using a vb script similar to the one below, the script runs using a group policy. Dim WshNetwork Set WshNetwork = WScript.CreateObject("WScript.Network") WshNetwork.MapNetworkDrive "g:", "\\\Saturn\data\" WshNetwork.MapNetworkDrive "k:", "\\\Saturn\stuff\" Works fine for Windows XP. Update: Copying the script locally and running it runs fine so I suspect the Group Policy isn't running the script on Windows 7. Many thanks Steve

    Read the article

  • Download file from vbscript?

    - by Eye of Hell
    I need a script that can be run on freshly installed windows xp+ and download specified files from internet, like http://www.python.org/ftp/python/2.6.2/python-2.6.2.msi Is it any easy way to do it without hand-crafting HTTP/FTP requests or using third-party programs like wget? I can suggest that WScript.CreateObject("internetexplorer.application") will do the magic, but documentation on it is extremely huge and Google is silent, as always :).

    Read the article

  • Script to set NO_HEARTBEAT Flag

    - by Koppar
    The new plugin provides some flags to help debug the browser side VM. Below are the flags: JPI_PLUGIN2_DEBUG=1JPI_PLUGIN2_VERBOSE=1 The above 2 provide tracing information JPI_PLUGIN2_NO_HEARTBEAT = 1 This disables sending of  heartbeat messages between browser side VM and the client JVM instance(s). This lets the client JVM stay independent of browser side VM. These are to be set as system environment variables. Many a times we are required to set them using scripts. Here is a small script to achieve the same: -----------set_jpi_flags.vbs------------------------------------------ Set WSHShell = WScript.CreateObject("WScript.Shell")Set WshEnv = WshShell.Environment("USER")WshEnv("JPI_PLUGIN2_NO_HEARTBEAT") = "1"WshEnv("JPI_PLUGIN2_DEBUG") = "1"WshEnv("JPI_PLUGIN2_VERBOSE") = "1"WScript.Echo WshEnv("JPI_PLUGIN2_NO_HEARTBEAT")   ---- displays the value of the NO_HEARTBEAT var ---------------------------------------------------------------------------

    Read the article

  • Issues passing values to shader

    - by numerical25
    I am having issues passing values to my shader. My application compiles fine, but my cube object won't shade. Below is majority of my code. Most of my code for communicating with my shader is in createObject method myGame.cpp #include "MyGame.h" #include "OneColorCube.h" /* This code sets a projection and shows a turning cube. What has been added is the project, rotation and a rasterizer to change the rasterization of the cube. The issue that was going on was something with the effect file which was causing the vertices not to be rendered correctly.*/ typedef struct { ID3D10Effect* pEffect; ID3D10EffectTechnique* pTechnique; //vertex information ID3D10Buffer* pVertexBuffer; ID3D10Buffer* pIndicesBuffer; ID3D10InputLayout* pVertexLayout; UINT numVertices; UINT numIndices; }ModelObject; ModelObject modelObject; // World Matrix D3DXMATRIX WorldMatrix; // View Matrix D3DXMATRIX ViewMatrix; // Projection Matrix D3DXMATRIX ProjectionMatrix; ID3D10EffectMatrixVariable* pProjectionMatrixVariable = NULL; ID3D10EffectVectorVariable* pLightVarible = NULL; bool MyGame::InitDirect3D() { if(!DX3dApp::InitDirect3D()) { return false; } D3D10_RASTERIZER_DESC rastDesc; rastDesc.FillMode = D3D10_FILL_WIREFRAME; rastDesc.CullMode = D3D10_CULL_FRONT; rastDesc.FrontCounterClockwise = true; rastDesc.DepthBias = false; rastDesc.DepthBiasClamp = 0; rastDesc.SlopeScaledDepthBias = 0; rastDesc.DepthClipEnable = false; rastDesc.ScissorEnable = false; rastDesc.MultisampleEnable = false; rastDesc.AntialiasedLineEnable = false; ID3D10RasterizerState *g_pRasterizerState; mpD3DDevice->CreateRasterizerState(&rastDesc, &g_pRasterizerState); //mpD3DDevice->RSSetState(g_pRasterizerState); // Set up the World Matrix D3DXMatrixIdentity(&WorldMatrix); D3DXMatrixLookAtLH(&ViewMatrix, new D3DXVECTOR3(0.0f, 10.0f, -20.0f), new D3DXVECTOR3(0.0f, 0.0f, 0.0f), new D3DXVECTOR3(0.0f, 1.0f, 0.0f)); // Set up the projection matrix D3DXMatrixPerspectiveFovLH(&ProjectionMatrix, (float)D3DX_PI * 0.5f, (float)mWidth/(float)mHeight, 0.1f, 100.0f); if(!CreateObject()) { return false; } return true; } //These are actions that take place after the clearing of the buffer and before the present void MyGame::GameDraw() { static float rotationAngleY = 15.0f; static float rotationAngleX = 0.0f; static D3DXMATRIX rotationXMatrix; static D3DXMATRIX rotationYMatrix; // create the rotation matrix using the rotation angle D3DXMatrixRotationY(&rotationYMatrix, rotationAngleY); D3DXMatrixRotationX(&rotationXMatrix, rotationAngleX); //rotationAngleY += (float)D3DX_PI * 0.002f; //rotationAngleX += (float)D3DX_PI * 0.001f; WorldMatrix = rotationYMatrix * rotationXMatrix; // Set the input layout mpD3DDevice->IASetInputLayout(modelObject.pVertexLayout); // Set vertex buffer UINT stride = sizeof(VertexPos); UINT offset = 0; mpD3DDevice->IASetVertexBuffers(0, 1, &modelObject.pVertexBuffer, &stride, &offset); // Set primitive topology mpD3DDevice->IASetPrimitiveTopology(D3D10_PRIMITIVE_TOPOLOGY_TRIANGLELIST); //ViewMatrix._43 += 0.005f; // Combine and send the final matrix to the shader D3DXMATRIX finalMatrix = (WorldMatrix * ViewMatrix * ProjectionMatrix); pProjectionMatrixVariable->SetMatrix((float*)&finalMatrix); // make sure modelObject is valid // Render a model object D3D10_TECHNIQUE_DESC techniqueDescription; modelObject.pTechnique->GetDesc(&techniqueDescription); // Loop through the technique passes for(UINT p=0; p < techniqueDescription.Passes; ++p) { modelObject.pTechnique->GetPassByIndex(p)->Apply(0); // draw the cube using all 36 vertices and 12 triangles mpD3DDevice->Draw(36,0); } } //Render actually incapsulates Gamedraw, so you can call data before you actually clear the buffer or after you //present data void MyGame::Render() { DX3dApp::Render(); } bool MyGame::CreateObject() { //Create Layout D3D10_INPUT_ELEMENT_DESC layout[] = { {"POSITION",0,DXGI_FORMAT_R32G32B32_FLOAT, 0 , 0, D3D10_INPUT_PER_VERTEX_DATA, 0}, {"COLOR",0,DXGI_FORMAT_R32G32B32A32_FLOAT, 0 , 12, D3D10_INPUT_PER_VERTEX_DATA, 0}, {"NORMAL",0,DXGI_FORMAT_R32G32B32A32_FLOAT, 0 , 24, D3D10_INPUT_PER_VERTEX_DATA, 0} }; UINT numElements = (sizeof(layout)/sizeof(layout[0])); modelObject.numVertices = sizeof(vertices)/sizeof(VertexPos); for(int i = 0; i < modelObject.numVertices; i += 3) { D3DXVECTOR3 out; D3DXVECTOR3 v1 = vertices[0 + i].pos; D3DXVECTOR3 v2 = vertices[1 + i].pos; D3DXVECTOR3 v3 = vertices[2 + i].pos; D3DXVECTOR3 u = v2 - v1; D3DXVECTOR3 v = v3 - v1; D3DXVec3Cross(&out, &u, &v); D3DXVec3Normalize(&out, &out); vertices[0 + i].normal = out; vertices[1 + i].normal = out; vertices[2 + i].normal = out; } //Create buffer desc D3D10_BUFFER_DESC bufferDesc; bufferDesc.Usage = D3D10_USAGE_DEFAULT; bufferDesc.ByteWidth = sizeof(VertexPos) * modelObject.numVertices; bufferDesc.BindFlags = D3D10_BIND_VERTEX_BUFFER; bufferDesc.CPUAccessFlags = 0; bufferDesc.MiscFlags = 0; D3D10_SUBRESOURCE_DATA initData; initData.pSysMem = vertices; //Create the buffer HRESULT hr = mpD3DDevice->CreateBuffer(&bufferDesc, &initData, &modelObject.pVertexBuffer); if(FAILED(hr)) return false; /* //Create indices DWORD indices[] = { 0,1,3, 1,2,3 }; ModelObject.numIndices = sizeof(indices)/sizeof(DWORD); bufferDesc.ByteWidth = sizeof(DWORD) * ModelObject.numIndices; bufferDesc.BindFlags = D3D10_BIND_INDEX_BUFFER; initData.pSysMem = indices; hr = mpD3DDevice->CreateBuffer(&bufferDesc, &initData, &ModelObject.pIndicesBuffer); if(FAILED(hr)) return false;*/ ///////////////////////////////////////////////////////////////////////////// //Set up fx files LPCWSTR effectFilename = L"effect.fx"; modelObject.pEffect = NULL; hr = D3DX10CreateEffectFromFile(effectFilename, NULL, NULL, "fx_4_0", D3D10_SHADER_ENABLE_STRICTNESS, 0, mpD3DDevice, NULL, NULL, &modelObject.pEffect, NULL, NULL); if(FAILED(hr)) return false; pProjectionMatrixVariable = modelObject.pEffect->GetVariableByName("Projection")->AsMatrix(); pLightVarible = modelObject.pEffect->GetVariableByName("lightSource")->AsVector(); //Dont sweat the technique. Get it! LPCSTR effectTechniqueName = "Render"; D3DXVECTOR3 vLight(10.0f, 10.0f, 10.0f); pLightVarible->SetFloatVector(vLight); modelObject.pTechnique = modelObject.pEffect->GetTechniqueByName(effectTechniqueName); if(modelObject.pTechnique == NULL) return false; //Create Vertex layout D3D10_PASS_DESC passDesc; modelObject.pTechnique->GetPassByIndex(0)->GetDesc(&passDesc); hr = mpD3DDevice->CreateInputLayout(layout, numElements, passDesc.pIAInputSignature, passDesc.IAInputSignatureSize, &modelObject.pVertexLayout); if(FAILED(hr)) return false; return true; } And below is my shader effect.fx matrix Projection; float3 lightSource; float4 lightColor = {0.5, 0.5, 0.5, 0.5}; // PS_INPUT - input variables to the pixel shader // This struct is created and fill in by the // vertex shader struct PS_INPUT { float4 Pos : SV_POSITION; float4 Color : COLOR0; float4 Normal : NORMAL; }; //////////////////////////////////////////////// // Vertex Shader - Main Function /////////////////////////////////////////////// PS_INPUT VS(float4 Pos : POSITION, float4 Color : COLOR, float4 Normal : NORMAL) { PS_INPUT psInput; // Pass through both the position and the color psInput.Pos = mul( Pos, Projection ); psInput.Color = Color; psInput.Normal = Normal; return psInput; } /////////////////////////////////////////////// // Pixel Shader /////////////////////////////////////////////// float4 PS(PS_INPUT psInput) : SV_Target { float4 finalColor = 0; finalColor = saturate(dot(lightSource, psInput.Normal) * lightColor); return finalColor; } // Define the technique technique10 Render { pass P0 { SetVertexShader( CompileShader( vs_4_0, VS() ) ); SetGeometryShader( NULL ); SetPixelShader( CompileShader( ps_4_0, PS() ) ); } }

    Read the article

  • MSSOAP.SoapClient30 alternative for PHP

    - by sasa
    Hello, Can somebody help me with this - I need some tips or code to connect to wsdl service, send XML request and than print response on client side. I only have primer written in ASP.NET and need PHP alternative: function doXMLRequest(Xmltext) Set oSOAP = Server.CreateObject("MSSOAP.SoapClient30") oSOAP.ClientProperty("ServerHTTPRequest") = True oSOAP.mssoapinit sys_xmlservice, "", "", "" oSOAP.ConnectorProperty("Timeout") = 600000 myXMLResponse = oSOAP.XMLReq(XmlText) doXMLRequest=myXMLResponse set oSOAP=nothing end function Thanks in advance! :)

    Read the article

  • ASP/VBScript ServerXmlHttp Encoding

    - by colinramsay
    I'm pulling an RSS feed from a remote location using ServerXmlHttp: Dim httpRequest set httpRequest = server.createObject("Msxml2.ServerXMLHTTP.6.0") httpRequest.open "GET", "http://www.someurl.com/feed.xml", false httpRequest.send() response.write httpRequest.responseXML.xml However there must be encoding issues somewhere along the line as I'm seeing ???? where there should be some Japanese characters. Does anyone have any guidance when working with ServerXmlHttp? Thanks.

    Read the article

  • Sorted list of file names in a folder in VBA?

    - by Karsten W.
    Is there a way to get a sorted list of file names of a folder in VBA? Up to now, I arrived at Dim fso As Object Dim objFolder As Object Dim objFileList As Object Dim vFile As Variant Dim sFolder As String sFolder = "C:\Docs" Set fso = CreateObject("Scripting.FileSystemObject") Set objFolder = fso.GetFolder(sFolder) Set objFileList = objFolder.Files For Each vFile In objFileList ' do something ' Next vFile but it is crucial to be sure the processing order of the for loop is determined by the file names... Any help appreciated!

    Read the article

  • Kill explorer.exe with windows title

    - by matthias
    Hello, I'm new with programing and my question is now, how i can close some specific explorer.exe windows. My Problem is, i have a program that call some windows: Option Explicit Dim shell, expl1, expl2, expl3, Terminate Dim uprgExplorer set shell = WScript.CreateObject("WScript.Shell") set expl1 = shell.exec("C:\WINDOWS\explorer.exe c:\Documents and Settings") set expl2 = shell.exec("C:\WINDOWS\explorer.exe C:\WINDOWS\system32\CCM\Cache") set expl3 = shell.exec("C:\WINDOWS\explorer.exe c:\SCRIPTS\LOG") Now i will kill only this 3 windows NOT the explorer.exe. Can some one help me? Greetings, matthias

    Read the article

  • Hosting Microsoft Office application inside Silverlight 4?

    - by Ivan Zlatanov
    I know that Silverlight 4 has the support for COM interop via the AutomationFactory class. dynamic excel = AutomationFactory.CreateObject( "Excel.Application" ); excel.Visible = true; Easy. But this creates a separate process for the COM object. What I am missing here is if I am actually able to actually host the office document inside my silverlight application - in a ContentPresenter for example? Thanks in advance.

    Read the article

  • make an http post from server using user credentials - integrated security

    - by opensas
    I'm trying to make a post, from an asp classic server side page, using the user credentials... I'm using msxml2.ServerXMLHTTP to programatically make the post I've tried with several configurations in the IIS 5.1 site, but there's no way I can make IIS run with a specified account... I made a little asp page that runs whoami to verify what account the iis process i using... with IIS 5.1, using integrated security the process uses: my_machine\IWAM_my_machine I disable integrated security, and leave a domain account as anonymous access, and I get the same (¿?) to test the user I do the following private function whoami() dim shell, cmd set shell = createObject("wscript.shell") set cmd = shell.exec( server.mapPath( "whoami.exe" ) ) whoami = cmd.stdOut.readAll() set shell = nothing: set cmd = nothing end function is it because I'm issuing a shell command? I'd like to make http post calls, to another site that works with integrated security... So I need some way to pass the credentials, or at least to run with a specified account, and then configure the remote site to thrust that account... I thought that just setting the site to work with integrated security would be enough... How can I achieve such a thing? ps: with IIS6,happens the same but if I change the pool canfiguration I get the following info from whoami NT AUTHORITY\NETWORK SERVICE NT AUTHORITY\LOCAL SERVICE NT AUTHORITY\SYSTEM if I set a domain account, I get a "service unavailable" message... edit: found this http://www.microsoft.com/technet/prodtechnol/WindowsServer2003/Library/IIS/275269ee-1b9f-4869-8d72-c9006b5bd659.mspx?mfr=true it says what I supossed, "If an authenticated user makes a request, the thread token is based on the authenticated account of the user", but somehow I doesn't seem to work like that... what could I possibly be missing? edit: well the whoami thing is obviously fooling me, I tried with the following function private function whoami_db( serverName, dbName ) dim conn, data set conn = server.createObject("adodb.connection") conn.open "Provider=SQLOLEDB.1;Integrated Security=SSPI;" & _ "Initial Catalog=" & dbName & ";Data Source=" & serverName set data = conn.execute( "select suser_sname() as user_name" ) whoami_db = data("user_name") data.close: conn.close set data = nothing: set conn = nothing end function and everything seemed to be working fine... but how can I make msxml2.ServerXMLHTTP work with the user credentials???

    Read the article

  • wait for the second VB script untill ended from primary VB script

    - by yael
    Hi I have VB script that run second VB script The second VB script ask some questions from the input box My problem is that “MyShell.Run” not wait until SecondVBscript.vbs will ended And the Other VB syntax run immodestly also Need to wait for MyShell.Run process ended and then perform the Other VB syntax How can I do that? Set MyShell = Wscript.CreateObject("WScript.Shell") MyShell.Run " C:\Program Files\SecondVBscript.vbs" Set MyShell = Nothing Other VB syntax

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >