Search Results

Search found 371 results on 15 pages for 'createobject'.

Page 3/15 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • What is ADO ?

    - by Aamir Hasan
    What is ADO? ADO is a Microsoft technologyADO stands for ActiveX Data ObjectsADO is a Microsoft Active-X componentADO is automatically installed with Microsoft IISADO is a programming interface to access data in a databaseAccessing a Database from an ASP Page The common way to access a database from inside an ASP page is to: Create an ADO connection to a databaseOpen the database connectionCreate an ADO recordsetOpen the recordsetExtract the data you need from the recordsetClose the recordsetClose the connectionExample  <%set conn=Server.CreateObject("ADODB.Connection")conn.Provider="Microsoft.Jet.OLEDB.4.0"conn.Open(Server.Mappath("/db/northwind.mdb"))set rs = Server.CreateObject("ADODB.recordset")rs.Open "Select * from Customers", conndo until rs.EOF    for each x in rs.Fields       Response.Write(x.name)       Response.Write(" = ")       Response.Write(x.value & "<br />")    next    Response.Write("<br />")    rs.MoveNextlooprs.closeconn.close%> 

    Read the article

  • What is ADO ?

    - by Aamir Hasan
    What is ADO? ADO is a Microsoft technologyADO stands for ActiveX Data ObjectsADO is a Microsoft Active-X componentADO is automatically installed with Microsoft IISADO is a programming interface to access data in a databaseAccessing a Database from an ASP Page The common way to access a database from inside an ASP page is to: Create an ADO connection to a databaseOpen the database connectionCreate an ADO recordsetOpen the recordsetExtract the data you need from the recordsetClose the recordsetClose the connectionExample  <%set conn=Server.CreateObject("ADODB.Connection")conn.Provider="Microsoft.Jet.OLEDB.4.0"conn.Open(Server.Mappath("/db/northwind.mdb"))set rs = Server.CreateObject("ADODB.recordset")rs.Open "Select * from Customers", conndo until rs.EOF    for each x in rs.Fields       Response.Write(x.name)       Response.Write(" = ")       Response.Write(x.value & "<br />")    next    Response.Write("<br />")    rs.MoveNextlooprs.closeconn.close%> 

    Read the article

  • How do I use a datetime variable with createparameter in classic ASP?

    - by Frank Schmitt
    I'm having a heck of a time trying to create a parameterized query that binds a date variable into a stored procedure call: twoyearsago = dateadd("yyyy", -2, date()) DataConn.ConnectionString = myConnectionString DataConn.Open Set rs = Server.CreateObject("ADODB.Recordset") Set DataCmd = Server.CreateObject("ADODB.Command") DataCmd.ActiveConnection = DataConn DataCmd.CommandText = "exec myStoredProc ?, ?" DataCmd.Parameters.Append DataCmd.CreateParameter("@start", adDate, , 10, date()) DataCmd.Parameters.Append DataCmd.CreateParameter("@end", adDate, , 10, twoyearsago) rs.Open DataCmd The stored proc returns nothing (indicating the dates aren't making it through). If I hard code dates in the query, e.g.: DataCmd.CommandText = "exec myStoredProc '01/01/2008', '01/01/2010'" I get the results I would expect. Calling CStr on my dates (if that makes a difference) returns them in the above format.

    Read the article

  • Recordset Paging works in IIS6 but not in IIIS7

    - by Spudhead
    Hi there, I've got a recordset/paging set up - works fine in IIS6 but when I run the site on an IIS7 server I get the following error: Microsoft OLE DB Provider for SQL Server error '80004005' [DBNETLIB][ConnectionOpen (Connect()).]SQL Server does not exist or access denied. /orders.asp, line 197 the code looks like this: Set objPagingConn = Server.CreateObject("ADODB.Connection") objPagingConn.Open CONN_STRING Set objPagingRS = Server.CreateObject("ADODB.Recordset") objPagingRS.PageSize = iPageSize objPagingRS.CacheSize = iPageSize objPagingRS.Open strSQL, objPagingConn, adOpenStatic, adLockReadOnly, adCmdText iPageCount = objPagingRS.PageCount iRecordCount = objPagingRS.RecordCount Line 197 is the objPagingConn,Open ... line. I've got about 10 sites like this to migrate - is there a simple fix in IIS7??? Help is greatly appreciated! Many thanks, Martin

    Read the article

  • Object/Module not found: RDS from VB6 app to a Win2003 server

    - by Cyberherbalist
    I have a rather legacy application EXE written in VB6 and running on a Windows 2000 server that uses RDS (Remote Data Services) to access a business object DLL (also written in VB6) running on a Windows 2003 server. The DLL has never run on this server (we're moving the component off the old W2K server), but it is registered and defined as a component on the W2k+3 server. The specific code where the DLL is being called is: Private m_rdsDS As RDS.DataSpace Dim oARImport As Object Set oARImport = m_rdsDS.CreateObject("ARBatches.BL_ARBatches", txtWebServer) MsgBox oARImport.AddBatches(m_vConnParms, arbParseString, LinesFromFile) The CreateObject appears to work fine, but calling the method AddBatches raises the error number 8209 "Internet Server Error: Object/module not found." I'm leaning towards the idea that there is a permission issue somewhere at the root of the problem, but if this were the case, why wouldn't it say "You don't have permission"? I'd really like to rewrite the whole app but "they" won't let me.

    Read the article

  • Exposing .NET enums to COM clients{VBScript}

    - by Codex
    Am trying create of PoC for exposing/invoking various .NET objects from COM clients. The .NET library contains some classes and Enums. Am able to successfully access the classes in VBScript but not able to access the Enums. I know that Enums are value types and hence 'CreateObject' wont work in this case. But am able to access the same Enum in VBA code. Questions: How can I access the enums in VBScript? Why does the behaviour differ in the two COM clients? If VBA object browser can see the enum, why cant VBScript allow me to create one? .NET [ComVisible(true)] [GuidAttribute("ebc25cf6-9120-4283-b972-0e5520d0000E")] public enum Currency { GBP = CurrencyConvertorBL.CurrencyConvertorRef.Currency.GBP, USD = CurrencyConvertorBL.CurrencyConvertorRef.Currency.USD, INR = CurrencyConvertorBL.CurrencyConvertorRef.Currency.INR, AUD = CurrencyConvertorBL.CurrencyConvertorRef.Currency.AUD } VBA Private Function ConvertCurrency(fromCurrency As Currency, toCurrency As Currency) As Double VBScript ??? Set currencyConvertorCCY = CreateObject("CurrencyConvertorBL.Currency") Thanks in advance.

    Read the article

  • problem creating object "wscript.shell"

    - by sushant
    my script looks like: Dim WshShell, oExec Set WshShell = CreateObject("WScript.Shell") Set oExec = WshShell.Exec("cmd /c cd D:\d & D: & winzip32.exe -min -a D:\a") Do While oExec.Status = 0 WScript.Sleep 100 Loop WScript.Echo oExec.Status The idea was to use explorer to open these files. The problem I'm having though is on the line: Set WshShell = CreateObject("WScript.Shell") I keep getting the message ActiveX component can't create object: 'WScript.Shell' I'm totally confused because this exact same code runs fine if I write it in a .htm file. Why does my browser treat my .asp page differently than the .html file? How do i fix this problem?

    Read the article

  • Read and write into a file using VBScript

    - by Maddy
    How can we read and write some string into a text file using VBScript? I mean I have a text file which is already present so when I use this code below:- Set fso = CreateObject("Scripting.FileSystemObject" ) Set file = fso.OpenTextFile("C:\New\maddy.txt",1,1) This opens the file only for reading but I am unable to write anything and when I use this code:- Set fso = CreateObject("Scripting.FileSystemObject" ) Set file = fso.OpenTextFile("C:\New\maddy.txt",2,1) I can just use this file for writing but unable to read anything. Is there anyway by which we can open the file for reading and writing by just calling the OpenTextFile method only once. I am really new to VBScript. I am only familiar with C concepts. Is there any link to really get me started with VBScript? I guess I need to have a good knowledge of the objects and properties concepts.

    Read the article

  • File Folder copy

    - by Dario Dias
    Below is the VBScript code. If the file/s or folder exist I get scripting error, "File already exists". How to fix that? How to create folder only if it does not exist and copy files only that are new or do not exist in source path? How to insert the username (Point 1) after "Welcome" and at (Poin 3) instead of user cancelled? Can the buttons be changed to Copy,Update,Cancel instead of Yes,No,Cancel? (Point 2) The code: Set objFSO = CreateObject("Scripting.FileSystemObject") Set wshShell = WScript.CreateObject( "WScript.Shell" ) strUserName = wshShell.ExpandEnvironmentStrings( "%USERNAME%" ) Message = " Welcome to the AVG Update Module" & vbCR '1* Message = Message & " *****************************" & vbCR & vbCR Message = Message & " Click Yes to Copy Definition Files" & vbCR & vbCR Message = Message & " OR " & vbCR & vbCR Message = Message & " Click No to Update Definition Files." & vbCR & vbCR Message = Message & " Click Cancel (ESC) to Exit." & vbCR & vbCR X = MsgBox(Message, vbYesNoCancel, "AVG Update Module") '2* 'Yes Selected Script If X = 6 then objFSO.FolderExists("E:\Updates") if TRUE then objFSO.CreateFolder ("E:\Updates") objFSO.CopyFile "c:\Docume~1\alluse~1\applic~1\avg8\update\download\*.*", "E:\Updates\" , OverwriteFiles MsgBox "Files Copied Succesfully.", vbInformation, "Copy Success" End If 'No Selected Script If X = 7 then objFSO.FolderExists("Updates") if TRUE then objFSO.CreateFolder("Updates") objFSO.CopyFile "E:\Updates\*.*", "Updates", OverwriteFiles Message = "Files Updated Successfully." & vbCR & vbCR Message = Message & "Click OK to Launch AVG GUI." & vbCR & vbCR Message = Message & "Click Cancel (ESC) to Exit." & vbCR & vbCR Y = MsgBox(Message, vbOKCancel, "Update Success") If Y = 1 then Set WshShell = CreateObject("WScript.Shell") WshShell.Run chr(34) & "C:\Progra~1\avg\avg8\avgui.exe" & Chr(34), 0 Set WshShell = Nothing End if If Y = 3 then WScript.Quit End IF 'Cancel Selection Script If X = 2 then MsgBox "No Files have been Copied/Updated.", vbExclamation, "User Cancelled" '3* End if

    Read the article

  • Looping through worksheets in an Excel (xls) file using classic ASP on a win 2008 server

    - by Roy
    Hi, I have just migrated an older ASP solution to a windows 2008 server and everything works out fine except for using ADOX.Catalog to list all the worksheets in an uploaded xls file. I use the following code: <% Set objExcelCon = Server.CreateObject("ADODB.Connection") With objExcelCon .Provider = "Microsoft.ACE.OLEDB.12.0" .ConnectionString = "Data Source=" & strFilePath & "\" & strFileName & ";Extended Properties=Excel 12.0;" .Open End With Set objAdo = Server.CreateObject("ADOX.Catalog") ' Set ADOX activeConnection objAdo.activeConnection = objExcelCon ' Loop through tables (worksheets) For i = 0 To objAdo.Tables.Count - 1 response.Write objAdo.Tables(i).Name Next Set objExcelCon = Nothing Set objAdo = Nothing % When I run this i get no error message or anything. Anyone got any idea whats causing this? Best regards, Roy

    Read the article

  • Extract files from ZIP file with VBScript

    - by Tester101
    When extracting files from a ZIP file I was using the following. Sub Unzip(strFile) ' This routine unzips a file. NOTE: The files are extracted to a folder ' ' in the same location using the name of the file minus the extension. ' ' EX. C:\Test.zip will be extracted to C:\Test ' 'strFile (String) = Full path and filename of the file to be unzipped. ' Dim arrFile arrFile = Split(strFile, ".") Set fso = CreateObject("Scripting.FileSystemObject") fso.CreateFolder(arrFile(0) & "\ ") pathToZipFile= arrFile(0) & ".zip" extractTo= arrFile(0) & "\ " set objShell = CreateObject("Shell.Application") set filesInzip=objShell.NameSpace(pathToZipFile).items objShell.NameSpace(extractTo).CopyHere(filesInzip) fso.DeleteFile pathToZipFile, True Set fso = Nothing Set objShell = Nothing End Sub 'Unzip This was working, but now I get a "The File Exists" Error. What is the reason for this? Are there any alternatives?

    Read the article

  • EXcel VBA : Excel Macro to create table in a PowerPoint

    - by Balaji.N.S
    Hi friends, My requirement is I have a Excel which contains some data. I would like to select some data from the excel and open a PowerPoint file and Create Table in PowerPoint and populate the data in to it Right now I have succeeded in collecting the data from excel opening a PowerPoint file through Excel VBA Code. Code for Opening the PowerPoint from Excel. Set objPPT = CreateObject("Powerpoint.application") objPPT.Visible = True Dim file As String file = "C:\Heavyhitters_new.ppt" Set pptApp = CreateObject("PowerPoint.Application") Set pptPres = pptApp.Presentations.Open(file) Now how do I create the table in PowerPoint from Excel and populate the data. Timely help will be very much appreciated. Thanks in advance,

    Read the article

  • Can't connect twice to linked table using ACE/JET driver

    - by Tmdean
    I'm trying to connect to an MS Access database linked table in VBScript. It works fine connecting the first time on one connection but if I close that connection and open a new one in the same script it gives me an error. test.vbs(13, 1) Microsoft Office Access Database Engine: ODBC--connection to '{Oracle in OraClient10g_home1}DB_NAME' failed. This is some code that triggers the error. TABLE_1 is an ODBC linked table in the test.mdb file. Dim cnn, rs Set cnn = CreateObject("ADODB.Connection") cnn.Open "Provider=Microsoft.ACE.OLEDB.12.0;Data source=test.mdb" Set rs = cnn.Execute("SELECT * FROM [TABLE_1]") rs.Close cnn.Close Set cnn = CreateObject("ADODB.Connection") cnn.Open "Provider=Microsoft.ACE.OLEDB.12.0;Data source=test.mdb" Set rs = cnn.Execute("SELECT * FROM [TABLE_1]") '' crashes here rs.Close cnn.Close This error does not occur if I try to access an ordinary Access table. Right now I'm thinking it's a bug in the Oracle ODBC driver.

    Read the article

  • msxml domdocument stops working when I move to staging server

    - by blockhead
    I have some code that looks like this: Set xmlHttp = Server.CreateObject("MSXML2.ServerXMLHTTP") xmlHttp.Open "Get", myRSSfile, false xmlHttp.Send() myXML = xmlHttp.ResponseText Set xmlResponse = Server.CreateObject("MSXML2.DomDocument") xmlResponse.async = false xmlResponse.LoadXml(myXML) Set xmlHttp = Nothing Set objLst = xmlResponse.getElementsByTagName("item") Set xmlResponse = Nothing NoOfHeadlines = objLst.length - 1 Response.Write NoOfHeadlines This worked find on my development server. When I moved it over to a staging server (which I have no control over, and no nothing about), NoOfHeadlines returns 0. It seems obvious to me that DomDocument is not working the way its supposed to. Is this a version issue? How do I find out what version of DomDocument is on the staging server? Is there another possibility?

    Read the article

  • Scripting.dictionary to c#

    - by naresh
    Facing one problem please help me.... We are product development company and our existing application is in ASP, I am trying to send scripting.dictionary object to c#'s com visible class. I am using the System.Collections.Generic class here is my code ASP: dim dictForm set dictForm=CreateObject("scripting.dictionary") dictForm("First") ="one" dictForm("Second") ="two" SET OBJMSGBOX = Server.CreateObject("DictionarySerializer.DictionarySerializer") call OBJMSGBOX.ConvertDictionary(dictForm) c#: [ComVisible(true)] public class DictionarySerializer : IXmlSerializable { Dictionary dict = new Dictionary(); public void ConvertDictionary(Dictionary dictionary) { this.dict = dictionary; } } I am getting error Invalid procedure call or argument: 'ConvertDictionary' Please tell me where I am going in wrong way.

    Read the article

  • In Coldfusion, how do I init a component that is located above the current path folder?

    - by Dan Sorensen
    If I have a folder structure that looks like this: / /bin/myComponent.cfc /reports/index.cfm How do I initiate myComponent.cfc from index.cfm? myService = createObject("component", "bin.myComponent"); Using the dot syntax, I know how to go to deeper folders, but how to do I go up a folder, and down into the other folder? Using slash syntax it would be something like this: ../bin/myComponent.cfc But createObject() doesn't work that way. I'd like to keep a relative path so that I can move this folder to another server without breaking the paths. Ideas? Thanks!

    Read the article

  • Script for run script

    - by user280926
    Hello everybody I have a script on vbscript Dim WSHShell, WinDir, Value, wshProcEnv, fso, Spath Set WSHShell = CreateObject("WScript.Shell") Dim objFSO, objFileCopy Dim strFilePath, strDestination Const OverwriteExisting = True Set objFSO = CreateObject("Scripting.FileSystemObject") Set windir = objFSO.getspecialfolder(0) objFSO.CopyFile "\\dv.rt.ru\SYSVOL\DV.RT.RU\scripts\shutdown.vbs", windir&"\", OverwriteExisting strComputer = "." Set objWMIService = GetObject("winmgmts:" _ & "{impersonationLevel=impersonate}!\\" _ & strComputer & "\root\cimv2") JobID = "1" Set colScheduledJobs = objWMIService.ExecQuery _ ("Select * from Win32_ScheduledJob") For Each objJob in colScheduledJobs objJob.Delete Next Set objNewJob = objWMIService.Get("Win32_ScheduledJob") errJobCreate = objNewJob.Create _ (windir & "\shutdown.vbs", "********093000.000000+660", _ True, 1 OR 2 OR 4 OR 8 OR 16 OR 32 OR 64, ,True, JobId) How make that shutdown.vbs not run once at 9:30 but run for 9:30 to 12:00

    Read the article

  • Does any one knows how to use the WinHttpRequest to login facebook or gmail in VB.NET(2010 Version)?

    - by ???
    Now, I can download the webpage source code to the RichTextBox. But now I want to use the WinHttpRequest to login facebook or gmail,etc. I tried to do, but it didn't work!Any one can help me? Thnak you! This is my code: Public Class Form1 Private Sub Button1_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles Button1.Click RichTextBox1.Text = winhttp("http://www.facebook.com") End Sub Function winhttp(ByVal URL As String) As String Dim pass, email As String pass = "my password" email = "myemail" Dim winHTTPReq : winHTTPReq = CreateObject("WinHttp.WinHttpRequest.5.1") Dim objhttp As Object = CreateObject("WinHttp.WinHttpRequest.5.1") Dim Data As String objhttp.Open("POST", URL, False) ''method objhttp.setRequestHeader("Content-Type", "application/x-www-form-urlencoded") objhttp.setRequestHeader("Referer", "your refresh url") objhttp.send("email=" & email & "&pass=" & pass & "&perm_login=on") objhttp.WaitForResponse() Data = objhttp.responseText Data = Replace(Data, " ", "") Data = Replace(Data, vbTab, "") Data = Replace(Data, vbCrLf, "") Data = Replace(Data, " ", "") Return Data End Function End Class

    Read the article

  • Unable to connect to sql database only from asp

    - by Brian
    In a VB6 program: Dim conn As Object Set conn = CreateObject("ADODB.Connection") conn.Open "DRIVER={SQL Server}; Server=(local)\aaa; Database=bbb; UID=ccc; PWD=ddd" In an ASP program: Sub ProcessSqlServer(conn) Set conn = Server.CreateObject("ADODB.Connection") conn.Open "DRIVER={SQL Server}; Server=(local)\aaa; Database=bbb; UID=ccc; PWD=ddd" The VB6 program works, the ASP program does not (see error below). I tried checking the event log for errors, but found nothing. Or more precisely, I did find local an activation permission error, but this was fixed once I added local launch/activation permission for Network Service to the Machine Debug Manager via the component services tool. Error: Microsoft OLE DB Provider for ODBC Drivers error '80004005' [Microsoft][ODBC SQL Server Driver]Timeout expired

    Read the article

  • Vbscript - Object Required for DateLastModified

    - by Kenny Bones
    I don't really know what's wrong right here. I'm trying to create a vbscript that basically checks two Folders for their files and compare the DateLastModified attribute of each and then copies the source files to the destination folder if the DateLastModified of the source file is newer than the existing one. I have this code: Dim strSourceFolder, strDestFolder Dim fso, objFolder, colFiles strSourceFolder = "c:\users\user\desktop\Source\" strDestFolder = "c:\users\user\desktop\Dest\" Set fso = CreateObject("Scripting.FileSystemObject") Set objFolder = fso.GetFolder(strSourceFolder) Set colFiles = objFolder.Files For each objFile in colFiles Dim DateModified DateModified = objFile.DateLastModified ReplaceIfNewer objFile, DateModified, strSourceFolder, strDestFolder Next Sub ReplaceIfNewer (sourceFile, DateModified, SourceFolder, DestFolder) Const OVERWRITE_EXISTING = True Dim fso, objFolder, colFiles, sourceFileName, destFileName Dim DestDateModified, objDestFile Set fso = CreateObject("Scripting.FileSystemObject") sourceFileName = fso.GetFileName(sourceFile) destFileName = DestFolder & sourceFileName if fso.FileExists(destFileName) Then objDestFile = fso.GetFile(destFileName) DestDateModified = objDestFile.DateLastModified msgbox "File last modified: " & DateModified msgbox "New file last modified: " & DestDateModified End if End Sub And I get the error: On line 34, Char 3 "Object required: 'objDestFile' But objDestFile IS created?

    Read the article

  • ASP Classic Named Parameter in Paramaterized Query: Must declare the scalar variable

    - by My Alter Ego
    I'm trying to write a parameterized query in ASP Classic, and it's starting to feel like i'm beating my head against a wall. I'm getting the following error: Must declare the scalar variable "@something". I would swear that is what the hello line does, but maybe i'm missing something... <% OPTION EXPLICIT %> <!-- #include file="../common/adovbs.inc" --> <% Response.Buffer=false dim conn,connectionString,cmd,sql,rs,parm connectionString = "Provider=SQLOLEDB.1;Integrated Security=SSPI;Data Source=.\sqlexpress;Initial Catalog=stuff" set conn = server.CreateObject("adodb.connection") conn.Open(connectionString) set cmd = server.CreateObject("adodb.command") set cmd.ActiveConnection = conn cmd.CommandType = adCmdText cmd.CommandText = "select @something" cmd.NamedParameters = true cmd.Prepared = true set parm = cmd.CreateParameter("@something",advarchar,adParamInput,255,"Hello") call cmd.Parameters.append(parm) set rs = cmd.Execute if not rs.eof then Response.Write rs(0) end if %>

    Read the article

  • Sending mail using CDO JavaScript error - Server is undefined

    - by Rotem
    Hi, I got this code to send email using SMTP server, I tried many configuration of it that I found online, also VBscript similar code, and non of it is working. I want to focus on this code, when I'm opening the HTA I'm getting error in line 8, says 'Server is undefined', What should I do to define it? var cdoConfig = Server.CreateObject("CDO.Configuration"); cdoConfig.Fields("cdoSMTPServerName") = "194.90.9.22"; var cdoMessage = Server.CreateObject("CDO.Message"); cdoMessage.Configuration = cdoConfig; var cdoBodyPart = cdoMessage.BodyPart; cdoMessage.To = "[email protected]"; cdoMessage.From = "[email protected]"; cdoMessage.Subject = "CDO Test in JScript"; cdoMessage.TextBody = "This is a test email sent using JScript."; cdoMessage.send(); Thanks, Rotem

    Read the article

  • VBScript: how to set values from recordset to string

    - by phill
    This is probably a beginner question, but how do you set a recordset to a string variable? Here is my code: Function getOffice (strname, uname) strEmail = uname WScript.Echo "email: " & strEmail Dim objRoot : Set objRoot = GetObject("LDAP://RootDSE") Dim objDomain : Set objDomain = GetObject("LDAP://" & objRoot.Get("defaultNamingContext")) Dim cn : Set cn = CreateObject("ADODB.Connection") Dim cmd : Set cmd = CreateObject("ADODB.Command") cn.Provider = "ADsDSOObject" cn.Open "Active Directory Provider" Set cmd.ActiveConnection = cn cmd.CommandText = "SELECT physicalDeliveryOfficeName FROM '" & objDomain.ADsPath & "' WHERE mail='" & strEmail & "'" cmd.Properties("Page Size") = 1 cmd.Properties("Timeout") = 300 cmd.Properties("Searchscope") = ADS_SCOPE_SUBTREE Dim objRS : Set objRS = cmd.Execute WScript.Echo objRS.Fields(0) Set cmd = Nothing Set cn = Nothing Set objDomain = Nothing Set objRoot = Nothing Dim arStore Set getOffice = objRS.Fields(0) Set objRS = Nothing End function When I try to run the function, it throws an error "vbscript runtime error: Type mismatch" I presume this means it can't set the string variable with a recordset value. How do I fix this problem?

    Read the article

  • Is vbscripting that difficult?

    - by eric young
    I need to write some vbscripts in my new project. I was told by other people that vbscripting is easy, but seems to me, it is not. For example, in the following example (provided by microsoft), these functions: CreateObject, CreateShortcut, as well as these property names: TargetPath, WindowStyle, Hotkey, etc, are used, but I just cannot find the corresponding API documentation about how to use them. In other words, how do you know you need to call these functions in your vbscripts? Visual Studio 2008/2010 do not have templates for vbscript either. Could anybody tell me what I am missing, and what the best way is to do vbscripting? set WshShell = WScript.CreateObject("WScript.Shell") strDesktop = WshShell.SpecialFolders("Desktop") set oShellLink = WshShell.CreateShortcut(strDesktop _ & "\MyExcel.lnk") oShellLink.TargetPath = _ "C:\Program Files\Microsoft Office\OFFICE11\EXCEL.EXE" oShellLink.WindowStyle = 1 oShellLink.Hotkey = "CTRL+SHIFT+F" oShellLink.IconLocation = _ "C:\Program Files\Microsoft Office\OFFICE11\EXCEL.EXE, 0" oShellLink.Description = "My Excel Shortcut" oShellLink.WorkingDirectory = strDesktop oShellLink.Save

    Read the article

  • calling two functions sequentially in vbscript with single click event

    - by sushant
    i need to call two function on a single click event. and also the functions shud get executed sequentially. i tried click me . but its not working.its not calling any of the functions. here is the complete code. sorry for formatting. function copy() Dim WshShell, oExec,g,h h="D:\d" g="xcopy " & h & " " & "D:\y\ /E" Set WshShell = CreateObject("WScript.Shell") Set oExec = WshShell.Exec(g) Do While oExec.Status = 0 WScript.Sleep 100 Loop WScript.Echo oExec.Status end function function zip() Dim WshShel, oExe Set WshShel = CreateObject("WScript.Shell") Set oExe = WshShel.Exec("cmd /c cd D:\d & D: & winzip32.exe -min -a D:\a") Do While oExe.Status = 0 WScript.Sleep 100 Loop WScript.Echo oExe.Status end function click me any help is appreciated.

    Read the article