Search Results

Search found 11180 results on 448 pages for 'serial port'.

Page 5/448 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • Simple BizTalk Orchestration & Port Tutorial

    - by bosuch
    (This is a reference for a lunch & learn I'm giving at my company) This demo will create a BizTalk process that monitors a directory for an XML file, loads it into an orchestration, and drops it into a different directory. There’s no real processing going on (other than moving the file from one location to another), but this will introduce you to Messages, Orchestrations and Ports. To begin, create a new BizTalk Project names OrchestrationPortDemo: When the solution has been created, right-click the OrchestrationPortDemo solution name and select Add -> New Item. Add a BizTalk Orchestration named DemoOrchestration: Click Add and the orchestration will be created and displayed in the BizTalk Orchestration Designer. The designer allows you to visually create your business processes: Next, you will add a message (the basic unit of communication) to the orchestration. In the Orchestration View, right-click Messages and select New Message. In the message properties window, enter DemoMessage as the Identifier (the name), and select .NET Classes -> System.Xml.XmlDocument for Message Type. This indicates that we’ll be passing a standard Xml document in and out of the orchestration. Next, you will add Send and Receive shapes to the orchestration. From the toolbox, drag a Receive shape onto the orchestration (where it says “Drop a shape from the toolbox here”). Next, drag a Send shape directly below the Receive shape. For the properties of both shapes, select DemoMessage for Message – this indicates we’ll be passing around the message we created earlier. The Operation box will have a red exclamation mark next to it because no port has been specified. We will do this in a minute. On the Receive shape properties, you must be sure to select True for Activate. This indicates that the orchestration will be started upon receipt of a message, rather than being called by another orchestration. If you leave it set to false, when you try to build the application you’ll receive the error “You must specify at least one already-initialized correlation set for a non-activation receive that is on a non self-correlating port.” Now you’ll add ports to the orchestration. Ports specify how your orchestration will send and receive messages. Drag a port from the toolbox to the left-hand Port Surface, and the Port Configuration Wizard launches. For the first port (the receive port), enter the following information: Name: ReceivePort Select the port type to be used for this port: Create a new Port Type Port Type Name: ReceivePortType Port direction of communication: I’ll always be receiving <…> Port binding: Specify later By choosing “Specify later” you are choosing to bind the port (choose where and how it will send or receive its messages) at deployment time via the BizTalk Server Administration console. This allows you to change locations later without building and re-deploying the application. Next, drag a port to the right-hand Port Surface; this will be your send port. Configure it as follows: Name: SendPort Select the port type to be used for this port: Create a new Port Type Port Type Name: SendPortType Port direction of communication: I’ll always be sending <…> Port binding: Specify later Finally, drag the green arrow on the ReceivePort to the Receive_1 shape, and the green arrow on the SendPort to the Send_1 shape. Your orchestration should look like this: Now you have a couple final steps before building and deploying the application. In the Solution Explorer, right-click on OrchestrationPortDemo and select Properties. On the Signing tab, click “Sign the assembly”, and choose <New…> from the drop-down. Enter DemoKey as the Key file name, and deselect “Protect my key file with a password”. This will create the file DemoKey.snk in your solution. Signing the assembly gives it a strong name so that it can be deployed into the global assembly cache (GAC). Next, click the Deployment tab, and enter OrchestrationPortDemo as the Application Name. Save your solution. Click “Build OrchestrationPortDemo”. Your solution should (hopefully!) build with no errors. Click “Deploy OrchestrationPortDemo”. (Note – If you’re running Server 2008, Vista or Win7, you may get an error message. If so, close Visual Studio and run it as an administrator) That’s it! Your application is ready to be configured and fired up in the BizTalk Server Administration console, so stay tuned!

    Read the article

  • Is it possible to make a persistent USB serial port regardless ofthe existence of the USB device?

    - by Keith Nicholas
    USB serial ports, especially devices which emulate serial ports, don't quite behave the same as old serial ports, which causes a few problems with some software. old serial ports, always existed, they never come and go out of existence. With USB devices that emulate serial ports, they come and go depending on whether they are powered / reset etc. Is there a way under windows to make the USB serial port permanently exist regardless of the presence of the device? (not just come back as the same name as it was before).

    Read the article

  • Can someone access my locally ran website even if I haven't specified any port forwarding?

    - by user701510
    I am using Xampp so I can test my web application directly on my own computer. I am concerned that someone can access my Xampp site since I am still connected to the internet. However, I have NOT explicitly enabled any port forwarding with respect to my Xampp site in my router firewall settings. Furthermore, I am using a dynamic ip address. Given the factors already stated, can someone from outside my local network still access my locally ran website?

    Read the article

  • Cannot start serial over lan on iDrac6

    - by Bryan Agee
    I have a couple of Dell R610/R710 servers loaded with iDrac6 system management boards. I figured out how to log into the SM CLP with ssh. According to the dell documentation, I should be able to start a console session by running: start /system1/sol1 but I get the following failure message: cmdstat status : 3 status_tag : COMMAND EXECUTION FAILED job job_id : 12 joberr errtype : 1 errtype_desc : Other cimstat : 6 cimstat_desc : CIM_ERR_NOT_FOUND severity : 2 severity_desc : Low /system1/sol1 started FAILED at Sun Sep 16 00:20:58 2012 I have enabled the serial-over-lan via the web interface and rebooted, but nothing seems to make them available.

    Read the article

  • Snow Leopard Compatible Drivers for Moschip MCS7720 USB-to-Serial Controller

    - by Kristopher Johnson
    We are using Cables Unlimited USB-2925 USB-to-Dual-DB9 serial cables, which use the Moschip MCS7720 controller. We have downloaded the newest driver from http://www.moschip.com/mcs7720.php, but that driver was last updated in 2005. It does not seem to be working with Macs running OS X 10.6 Snow Leopard. We have sent emails to the support addresses for both Cables Unlimited and Moschip. Cables Unlimited says they are checking with Moschip. No responses from Moschip yet. Does anyone know of any updates for this driver, or are there any ways to get the driver to work with Snow Leopard?

    Read the article

  • Windows serial console

    - by MikeyB
    How do I enable a serial console on Windows (2008 and/or 2012) such that I can log into it like the Good Old Days of Real Servers and issue provisioning commands, ideally via PowerShell? $ cu -l /dev/ttyS0 Connected. Welcome to ad1.adlab.brazzers.com Microsoft Windows [Version 6.1.7601] Copyright (C) 2009 Microsoft Corporation. All rights reserved. Login: Administrator Password: PS C:\Users\Administrator> New-NetIPAddress –InterfaceAlias eth0 –IPv4Address 192.168.101.11 –PrefixLength 24 -DefaultGateway 192.168.101.1 PS C:\Users\Administrator>

    Read the article

  • Help accessing Beagle over serial with Minicom/GTKTerm

    - by mrgordon
    I am trying to access a brand new Beagle Board from Ubuntu or Mac over serial using the setup seen here: http://specialcomp.com/beagleboard/RevC1.htm I got Minicom and GTKTerm installed on the Ubuntu box. I set up the correct baud rate, turned off flow control, and have tried ttyUSB0 and ttyS0. Once minicom is configured properly, I should just see the init text from the board appear if I have minicom open in terminal while I plug in the board, correct? dmesg shows ttyUSB0 on the computer has been connected to ttyS0 on the beagle.

    Read the article

  • Filtering serial port io

    - by mr odus
    I am currently working on a project where I communicate with hardware via a com port on its respective pc(win xp or 7) It is a fairly large project and sifting through the log file can be a bit of pain. This is my current setup. I use putty to do the actual serial communication, and write it to a log file. Then using MinGW Msys I filter it using tail -f "puttyLog" | grep -i "search term" Is there a better way to do this? I mean specifically filtering the input in realtime. Not that mine is terrible, but it still involves having to read from a log and sometimes there have been hangups where it will be delayed for a minute or 2. I have used software in the past with a main io window and then internal filter panels, but can no longer remember or find it.

    Read the article

  • Port Forwarding on 80 vs. 8080

    - by Chadworthington
    I am able to access this url (Don't bother clicking on it, it's just an example): http://my.url.com/ This web site works: http://localhost:8080/tfs/web/ I setup my router to forward port 80 to the PC hosting the web site. I also forward port 8080 to the same box. But when I try to access this url I get the eror "Page Cannot be displayed:" http://my.url.com:8080/tfs/web/ I fwded port 8080 the same way I fwded port 80. I also turned off Windows Firewall, in case it was blocking port 8080. Any theories why port 80 works but 8080 does not?

    Read the article

  • CNet router - no field for private port

    - by Aadit M Shah
    I'm trying to configure port forwarding on my CNet router for a locally hosted HTTP server. The model number of my router is CQR-981 and the firmware version is 1.0.43. The problem is that there's no field to enter the private port of the HTTP server (the local port). According to the manual there should be one. Here's a picture of the manual: Here's a screenshot of my router page for port forwarding (with no field for private port): Is there some way I can circumvent this problem. Perhaps manually make an HTTP request to the HTTP server on the router to update the table with the private port number, or perhaps update my firmware to solve this problem.

    Read the article

  • Strange port forwarding problem

    - by rAyt
    I've got a strange port forwarding problem. The port forwarding to my internal webserver (10.0.0.10 on Port 80) works without a problem but the port forwarding to a windows server (10.0.0.15) on port 3389 doesn't work. The port 3389 is open. Any ideas? thanks! #!/bin/sh IPTABLES="/sbin/iptables" $IPTABLES --flush $IPTABLES --table nat --flush $IPTABLES --delete-chain $IPTABLES --table nat --append POSTROUTING --out-interface eth0 -j MASQUERADE $IPTABLES -t nat -A PREROUTING -p tcp -i eth0 -d 188.40.XXX.XXX --dport 3389 -j DNAT --to 10.0.0.15:3389 $IPTABLES -t nat -A PREROUTING -p tcp -i eth0 -d 188.40.XXX.XXX --dport 80 -j DNAT --to 10.0.0.10:80 $IPTABLES -t nat -A PREROUTING -p tcp -i eth0 -d 188.40.XXX.XXX --dport 222 -j DNAT --to 10.0.0.10:22 $IPTABLES --append FORWARD --in-interface eth1 -j ACCEPT

    Read the article

  • Why is System listening on port 8000?

    - by poke
    I noticed by accident today that I have some unknown webserver listening on port 8000. Opening http://localhost:8000 just returns 404, so I don’t get any hint what exactly is listening there. I’ve used netstat -ano to find out, that the process with PID 4 is listening on that port. PID 4 is the System process. Why is my system listening on that port, without me actually starting a server? Or how can I find out what exactly is listening there? I’ve read the related questions about port 80 and port 443, but none of the services mentioned there were running on my system. And the other suggestions there didn’t work either. edit: The HTTP response of the server lists Microsoft-HTTPAPI/2.0 as the server. edit2: As requested by Shadok, here are the entries of TCPView with 8000 as the port. But I doubt it’s useful at all…

    Read the article

  • Port Redirection on Mac OS X Lion

    - by Andreas
    I have tried to solve this issue using pf but with no luck. Basically, I am trying to redirect incoming port 443 traffic to port 22. I have tried to set up a rule in a file and load it in pf but I get syntax error. Can anyone with more experience with pf provide some insight? Here's what I've attempted: pass in on en1 proto tcp from any to any port 443 rdr-to 127.0.0.1 port 22 and pass in quick proto tcp to port 443 rdr-to 127.0.0.1 port 22 I've been able to do this in MacOSX Snow Leopard with ipfw: sudo ipfw add 1443 forward 127.0.0.1,22 ip from any to any 443 in but it doesn't work in Lion (it gives me an Invalid Argument error).

    Read the article

  • TCP > COM1 for receiving messages and displaying on POS display pole

    - by JakeTheSnake
    I currently have a Java Applet running on my web page that communicates to a display pole via COM1. However since the Java update I can no longer run self-signed Java Applets and I figure it would just be easier to send an AJAX request back to the server and have the server send a response to a TCP port on the computer...the computer would need a TCP COM virtual adapter. How do I install a virtual adapter to go from a TCP port to COM1? I've looked into com0com and that is just confusing as hell to me, and I don't see how to connect any ports to COM1. I've tried tcp2com but it doesn't seem to install the service in Windows 7 x64. I've tried com2tcp and the interface seems like it WOULD work (I haven't tested), but I don't want an app running on the desktop...it needs to be a service that runs in the background. So to summarize how it would work: Web page on comp1 sends AJAX request to server Server sends text response to comp1 on port 999 comp1 has virtual COM port listening on port 999, sends data to COM1 pole displays data

    Read the article

  • SSH Server Timeout on port 22 but not on higher port

    - by mikelberger
    If I run an SSH server on my Windows 2008 server box on the default port 22 I always get Operation Timed Out on the client. If I run it on another port (say 2222) it works fine. I've opened up the firewall. Netstat shows that the server is listening on the correct port. I have used two different Windows SSH servers (freeSSHd and WinSSHD) and they both have the same result. What else could be causing the difference between running the SSH server on port 22 versus port 2222?

    Read the article

  • Configure PL2303-based USB-to-RS232 adapter to stay awake when no active device is present

    - by casualuser
    I am resurrecting some X10 devices with the aid of a USB-to-RS232 adapter. The problem is, that the adapter only works with the Firecracker device when there is another serial device on the line (the Firecracker is a pass-through device that monitors the RTS and DTR lines to do its magic). Is the PL2303 going to sleep without a real device on the line? Is there an option or command to keep it awake? Is there a cable configuration that would make it work without a real serial device present?

    Read the article

  • Lighttpd based server issues crop up when port forwarding

    - by michael
    I have four host computers running lighttpd webservers. they are sitting behind a hspa modem, which each occupying a http port between [81 - 84]. 80 is taken by the modem itself. The port forwarding is setup correctly, however, only a portion of any webpage I request from any of the hosts comes through (they all fails after %20 of the page). If I put the host on port 81 into the dmz, it serves pages fine. The others do not respond to the dmz treatment. Is it possible the web content on the hosts somehow require ports aside from their respective http port? Or is it possible that even though the server.port in the lighttpd_ssl.conf file is set, the individual hosts are still expecting to serve on port 80? I am not familiar with lighttpd, nor did i set them up. they are running on video encoders i purchased. I can grab any files from them required for further information on the problem.

    Read the article

  • Linux - serial port read returning EAGAIN...

    - by Andre
    Hello all! I am having some trouble reading some data from a serial port I opened the following way. I've used this instance of code plenty of times and all worked fine, but now, for some reason that I cant figure out, I am completely unable to read anything from the serial port. I am able to write and all is correctly received on the other end, but the replies (which are correctly sent) are never received (No, the cables are all ok ;) ) The code I used to open the serial port is the following: fd = open("/dev/ttyUSB0", O_RDWR | O_NONBLOCK | O_NOCTTY); if (fd == -1) { Aviso("Unable to open port"); return (fd); } else { //Get the current options for the port... bzero(&options, sizeof(options)); /* clear struct for new port settings */ tcgetattr(fd, &options); /*-- Set baud rate -------------------------------------------------------*/ if (cfsetispeed(&options, SerialBaudInterp(BaudRate))==-1) perror("On cfsetispeed:"); if (cfsetospeed(&options, SerialBaudInterp(BaudRate))==-1) perror("On cfsetospeed:"); //Enable the receiver and set local mode... options.c_cflag |= (CLOCAL | CREAD); options.c_cflag &= ~PARENB; /* Parity disabled */ options.c_cflag &= ~CSTOPB; options.c_cflag &= ~CSIZE; /* Mask the character size bits */ options.c_cflag |= SerialDataBitsInterp(8); /* CS8 - Selects 8 data bits */ options.c_cflag &= ~CRTSCTS; // disable hardware flow control options.c_iflag &= ~(IXON | IXOFF | IXANY); // disable XON XOFF (for transmit and receive) options.c_cflag |= CRTSCTS; /* enable hardware flow control */ options.c_cc[VMIN] = 0; //min carachters to be read options.c_cc[VTIME] = 0; //Time to wait for data (tenths of seconds) //Set the new options for the port... tcflush(fd, TCIFLUSH); if (tcsetattr(fd, TCSANOW, &options)==-1) { perror("On tcsetattr:"); } PortOpen[ComPort] = fd; } return PortOpen[ComPort]; After the port is initializeed I write some stuff to it through simple write command... int nc = write(hCom, txchar, n); where hCom is the file descriptor (and it's ok), and (as I said) this works. But... when I do a read afterwards, I get a "Resource Temporarily Unavailable" error from errno. I tested select to see when the file descriptor had something t read... but it always times out! I read data like this: ret = read(hCom, rxchar, n); and I always get an EAGAIN and I have no idea why. All help would be appreciated. Cheers

    Read the article

  • How to set up a serial connection to a Windows 7 computer

    - by oli_arborum
    I need to set up a "dial in" connection to a Windows 7 (Ultimate) computer via a serial null-modem cable to be able to connect from a Windows XP client to that computer and exchange data over IP. Question 1: How do I do that? I did neither find the information via Google nor in the MSDN. Seems like no one tried ever before... ;-) I already managed to install a legacy modem device called "Communications cable between two computers" and found the menu entry "New Incoming Connection..." in Network and Internet Network Connections. When I finish this wizard I get the message that the "Routing and Remote Access service" cannot be started. In the event viewer I see the following error messages: "The currently configured authentication provider failed to load and initialize successfully. The requested name is valid, but no data of the requested type was found." (Source: RemoteAccess, EventID: 20152) "The Routing and Remote Access service terminated with service-specific error The requested name is valid, but no data of the requested type was found." (Source: Service Control Manager, EventID: 7024) The Windows 7 installation is "naked", i.e. no additional software or services are installed. Question 2: Am I on the right path to set up the connection? Question 3: How can I get the Routing and Remote Access service running?

    Read the article

  • Adjust parameters of serial port reading

    - by clinisbut
    Hello. I'm facing a particular issue that regards serial communication under win32. I'm communicating with a device can only accept frames when it is not already communicating. So I must find a valid frame and then inmediatelly send my request. I developed a class named Serial that handles basic operations on serial port (open, close, read, write) and then a Thread calls inside a loop read and write functions. Thread loop //Device is an object of class Serial while( device->isOpen() && !terminate ) { unsigned int readed = 0; unsigned long error = ERROR_SUCCESS; unsigned char* data = device->read( &readed, &error ); if( error==ERROR_SUCCESS ) { //If data received, deliver to upper level if( readed>0 ) { QByteArray output( (const char*)data, (signed int)readed ); emit dataArrived( output, readed ); } } else { //unrelated stuff } //Here I manage the writting issue //Only when nothing is received, and Upper layer wants to send a frame //(Upper layer only will mark as something to send when it detects a valid frame) if( readed==0 ) { out_lock.lock(); //If something to send... if( something_to_send > 0 ) { if( device->write( output_buffer, output_size, &error ) ) { //things... } } } } The Thread basically keeps reading, and when nothing is received, sees if somebody has signaled to send a frame (this means that a valid frame is just received). When this happens, it writes the frame through serial port. Here comes my problem. Inside the Serial::read() function: I use the overlapped way of reading: ::ClearCommError( handle, &dwErrors, &stat); if( stat.cbInQue ) { //If there's something to read, read it, please note the bytes to read parameter, here 1. bool ok = ::ReadFile( handle, buffer_in, 1, &bytes_read, &ov_reader ); if( !ok ) { DWORD _error = ::GetLastError(); if( _error == ERROR_IO_PENDING ) { DWORD result = ::WaitForMultipleObjects( 2, waiters, FALSE,INFINITE ); switch( result ) { //Eventshutdown case WAIT_OBJECT_0: /*code omitted*/break; case WAIT_OBJECT_0+1: ok = ::GetOverlappedResult( handle, &ov_reader, &bytes_read, true ); //check ok value omitted break; } } } } if( bytes_read>0 ) { *size = bytes_read; } Here starts my problem. When device sends me small frames (around 30 bytes) everything works fine, but when larger frames are sent, the code is not able to find any free time between frames causing the thread to never be able send any frame because readed is never 0. If I increase the number of bytes to read inside the read() function, lose the ability to detect when the device "listens": bool ok = ::ReadFile(handle, buffer_in, 50, &bytes_read, &ov_reader ); This happens because my app can receive the end of a frame together with the start of the next one. This behaviour is very common. In the other hand, if I change the INFINITE argument by a valid timeout in the WaitForMultipleObjects function, I lose data. So my question basically is... what I'm doing wrong? Why when reading 1 byte each time I don't find any free time to send my own frames? Thank you

    Read the article

  • PORT FORWARDING TO PUT MY WEB SERVER ON THE INTERNET

    - by Chadworthington
    I went to http://canyouseeme.org/ to check to see what my external IP address. Regardless of what port I enter, it tells me that the port is blocked. I have a LinkSys router that basically has the default settings with the exception that I have WEP encrptin setup and I have forwarded a few ports, including 80 and 69. I forwarded them to the 192.x.x.103 IP address of the PC which is running IIS. That PC runs Symantec Endpoint Protection, which I right mouse clicked in the tray to Disable. These steps used to make my PC visible so I could host my own web site in IIS on port 80, or some other port, like 69. Yet, the Open Port tool cannot see my IP when it checks eiether port and when I navigate to http://my external ip/ I get "page cant be displayed" At first I was thinking that maybe Comcast is blocking port 80, but 69 doesnt work eiether. I do not see any other blockking set up in my router and, as I mentioned, I went with teh defaults except where discussed. This is a corporate PC and Symantec End Point Protecion is new to it (this previously worked on teh same PC with Symantec Protection Agent), but I thought that disabling Sym End Pt from the tray, that that would effectively neutralize it. I do not have the rights to kill the program itself. Any suggestions on what else to try to make my PC externally visible?

    Read the article

  • Advice on logic circuits and serial communications

    - by Spencer Ruport
    As far as I understand the serial port so far, transferring data is done over pin 3. As shown here: There are two things that make me uncomfortable about this. The first is that it seems to imply that the two connected devices agree on a signal speed and the second is that even if they are configured to run at the same speed you run into possible synchronization issues... right? Such things can be handled I suppose but it seems like there must be a simpler method. What seems like a better approach to me would be to have one of the serial port pins send a pulse that indicates that the next bit is ready to be stored. So if we're hooking these pins up to a shift register we basically have: (some pulse pin)-clk, tx-d Is this a common practice? Is there some reason not to do this? EDIT Mike shouldn't have deleted his answer. This I2C (2 pin serial) approach seems fairly close to what I did. The serial port doesn't have a clock you're right nobugz but that's basically what I've done. See here: private void SendBytes(byte[] data) { int baudRate = 0; int byteToSend = 0; int bitToSend = 0; byte bitmask = 0; byte[] trigger = new byte[1]; trigger[0] = 0; SerialPort p; try { p = new SerialPort(cmbPorts.Text); } catch { return; } if (!int.TryParse(txtBaudRate.Text, out baudRate)) return; if (baudRate < 100) return; p.BaudRate = baudRate; for (int index = 0; index < data.Length * 8; index++) { byteToSend = (int)(index / 8); bitToSend = index - (byteToSend * 8); bitmask = (byte)System.Math.Pow(2, bitToSend); p.Open(); p.Parity = Parity.Space; p.RtsEnable = (byte)(data[byteToSend] & bitmask) > 0; s = p.BaseStream; s.WriteByte(trigger[0]); p.Close(); } } Before anyone tells me how ugly this is or how I'm destroying my transfer speeds my quick answer is I don't care about that. My point is this seems much much simpler than the method you described in your answer nobugz. And it wouldn't be as ugly if the .Net SerialPort class gave me more control over the pin signals. Are there other serial port APIs that do?

    Read the article

  • Port Forwarding to put my web server on The Internet

    - by Chadworthington
    I went to http://canyouseeme.org/ to check to see what my external IP address. Regardless of what port I enter, it tells me that the port is blocked. I have a LinkSys router that basically has the default settings with the exception that I have WEP encrptin setup and I have forwarded a few ports, including 80 and 69. I forwarded them to the 192.x.x.103 IP address of the PC which is running IIS. That PC runs Symantec Endpoint Protection, which I right mouse clicked in the tray to Disable. These steps used to make my PC visible so I could host my own web site in IIS on port 80, or some other port, like 69. Yet, the Open Port tool cannot see my IP when it checks eiether port and when I navigate to http://my external ip/ I get "page cant be displayed" At first I was thinking that maybe Comcast is blocking port 80, but 69 doesnt work eiether. I do not see any other blockking set up in my router and, as I mentioned, I went with teh defaults except where discussed. This is a corporate PC and Symantec End Point Protecion is new to it (this previously worked on teh same PC with Symantec Protection Agent), but I thought that disabling Sym End Pt from the tray, that that would effectively neutralize it. I do not have the rights to kill the program itself. Any suggestions on what else to try to make my PC externally visible?

    Read the article

  • Selecting Interface for SSH Port Forwarding

    - by Eric Pruitt
    I have a server that we'll call hub-server.tld with three IP addresses 100.200.130.121, 100.200.130.122, and 100.200.130.123. I have three different machines that are behind a firewall, but I want to use SSH to port forward one machine to each IP address. For example: machine-one should listen for SSH on port 22 on 100.200.130.121, while machine-two should do the same on 100.200.130.122, and so on for different services on ports that may be the same across all of the machines. The SSH man page has -R [bind_address:]port:host:hostport listed I have gateway ports enabled, but when using -R with a specific IP address, server still listens on the port across all interfaces: machine-one: # ssh -NR 100.200.130.121:22:localhost:22 [email protected] hub-server.tld (Listens for SSH on port 2222): # netstat -tan | grep LISTEN tcp 0 0 100.200.130.121:2222 0.0.0.0:* LISTEN tcp 0 0 :::22 :::* LISTEN tcp 0 0 :::80 :::* LISTEN Is there a way to make SSH forward only connections on a specific IP address to machine-one so I can listen to port 22 on the other IP addresses at the same time, or will I have to do something with iptables? Here are all the lines in my ssh config that are not comments / defaults: Port 2222 Protocol 2 SyslogFacility AUTHPRIV PasswordAuthentication yes ChallengeResponseAuthentication no GSSAPIAuthentication no GSSAPICleanupCredentials no UsePAM yes AcceptEnv LANG LC_CTYPE LC_NUMERIC LC_TIME LC_COLLATE LC_MONETARY LC_MESSAGES AcceptEnv LC_PAPER LC_NAME LC_ADDRESS LC_TELEPHONE LC_MEASUREMENT AcceptEnv LC_IDENTIFICATION LC_ALL AllowTcpForwarding yes GatewayPorts yes X11Forwarding yes ClientAliveInterval 30 ClientAliveCountMax 1000000 UseDNS no Subsystem sftp /usr/libexec/openssh/sftp-server

    Read the article

  • Opening and Testing Ports on Modem > Router Connection

    - by JakeTheSnake
    Working off of my last question, I can access my server's FTP over the LAN but not over the internet. I'm using Filezilla on port 666. My router/modem configuration is as such (similar to other post): 1) Modem connects to WAN 2) WAN port on modem connects to LAN port on Router 3) Modem internal IP address is 192.168.0.254 4) Router internal IP address is 192.168.0.1 5) Modem has DHCP turned OFF 6) Router has DHCP turned ON 7) Router is running Tomato firmware and it's set as 'Router' (not 'Gateway') 8) The internet is working (just had to say that) I've set up port forwarding both on the modem and router - both route port 666 to the IP address of 192.168.0.3 (TCP); that is the IP address of the server which has FileZilla running. I don't know if that's hindering anything but I've also tried it with just the modem and just the router...same result. I've also tried setting the server to be DMZ (both on router and modem). Neither router nor modem have anything in their logs about denying inbound traffic on port 666 so my ability to troubleshoot stops there. I've tried contacting my ISP (Telus, running on mobility plan...it's a "Smart" Hub) but they weren't much help. They said they only block port 25 and 80 and maybe a few others, but not most ports. I test whether or not the port is open by going to canyouseeme.org - I don't know whether or not that would produce a 'connection refused' result just based on the fact that the FTP requires a login...I'm not well versed on this matter. FWIW, sometimes I get a 'connection refused' error on canyouseeme.org but mostly it's 'connection timed out'. I don't know what else to do at this point.

    Read the article