  • Single-Purpose SSH account, exclusively for Reverse Port Forwarding

    - by drfloob
    On my Debian system, I'd like to create a user that is only allowed to do a Reverse Port Forward from their machine to my server, but I'm not sure how to create a limited user specifically for this purpose. For example, we'll call my server 'Sam' and my laptop 'Luke'. I'd like a user on Luke to be able to execute a reverse port forward ssh command to Sam, so that port 4321 on Sam is tunneled to port 4321 on Luke. For example: ssh -fnR 4321:localhost:4321 -l limitedUser Sam How can I create a user on Sam that is only allowed to execute this command?

    Read the article

  • DELL switch 6248 port and mac mapping using SNMP

    - by Brad
    I have a Dell 6248 switch. I connect some of my servers to it and want to know which server nic connected to which switch port. I try using snmpwalk to get this information, but I just can get mac/ip mapping of my server nic from switch, I still can't get which switch port it connect. I try a tool named Managed Switch Port Mapping tool, it can show which switch port is connected to which nic/ip. I use WireShare to get all snmp packets but still can't find what's the snmp oid to get this information. Anyone knows how to get this?

    Read the article

  • Adding port forwardings programmatically on a ControlMaster SSH session

    - by aef
    I just found out about the ControlMaster/ControlPath feature of OpenSSH, which allows you to use a single SSH connection to run multiple terminals. As I often use SSH to use port forwarding to get encrypted and authenticated VNC sessions I instantly recognized that you can't add port forwardings to a remote server to which you already have an established connection. This sucks. Sometimes later I found out that you can circumvent this limitation by typing ~C in a running SSH terminal session. This opens up a command-line which allows you to add or remove port forwardings. My quesion now is: How can I add port forwardings on an existing SSH session which is using the ControlMaster/ControlPath feature, without the need to have access to a terminal session inside that SSH session. I need this to enable my script which starts a secure tunneled VNC connection for me to add and later remove its port forwardings. (I know I could use a terminal multiplexer such as GNU Screen or tmux, actually I'm doing this already. But I like the idea of using just one SSH session for serveral reasons.)

    Read the article

  • Com port redirection from Windows 7 to Windows Server 2008 R2

    - by Ola Eldøy
    We use "Copy file.prn to \tsclient\com1" to print from a TS session to a locally attached serial printer. This works fine from Windows XP, but when trying it from a Windows 7 client computer, we get an "Access is denied" error message. And yes, the check box of COM port is selected on the Local Resources tab of the Remote Desktop Connection client. Any pointers? Has anyone even managed to do this successfully?

    Read the article

  • How can I debug a port/connectivity issue?

    - by rfw21
    I am running a simple WebSocket server on Amazon EC2 (Fedora Core). I've opened the relevant port using ec2-authorize, and checked that it's opened. Iptables is definitely not running. However I can't connect to the port from outside EC2. I've tried the following (my server is running on port 7000): telnet ec2-public-dns.xx.xx.xx.amazon.com 7000 (from within EC2: connects fine) nmap localhost (output includes line: 7000/tcp open afs3-fileserver) telnet ec2-public-dns.xx.xx.xx.amazon.com 7000 (this time from my local machine: I get "connection refused: Unable to connect to remote host") The strange thing is this: if I start Nginx on port 7000 then it works and I can connect from outside EC2! And the WebSocket server fails on port 80, where Nginx works fine. To me this suggests a problem with the WebSocket server, BUT I can connect to it successfully from within EC2. (And it works fine on a different VPS account). How can I debug this further? If anybody can stop me tearing my hair out, I'd be very grateful indeed :)

    Read the article

  • What is the difference between Port and Connector?

    - by Ali Essam
    I want to know the difference between Port and Connector in Computer (the physical ones),and how can i tell that this thing is a port or connector ? I know that both terms are used for the same purpose but Doctor in college asked us to show the difference between them,and i have searched for it but people just say that there is no difference. According to Wikipedia also Port and Connector are almost the same.

    Read the article

  • SSH Port Forward 22

    - by j1199dm
    I'm trying to set up the following: At work I want to create a local port that will forward to port 22 on my home server. ssh -L 56879:home:22 username@home -p 443 right now I'm testing this on my two machines at home, my ubuntu server and the other my iMac. iMac: 192.168.1.104 ubuntu: 192.168.1.103 iMac - ssh -p 443 -L 56879:192.168.1.103:22 [email protected] in my ~/.ssh/config on my iMac I have port set to 56879. so when I do git pull remoteserver:/path/to/repo.git on my iMac git will use ssh client on my iMac and use port 56879 since setup in config which should forward to 22 on my ubuntu machine. I keep getting connection refused? Any ideas?

    Read the article

  • port redirection on solaris 11

    - by mo3lyana
    I'm trying port forwarding on solaris 11. I have a mechine behind a server that use solaris 11. I try to access that mechine from the external port, and forwarded by solaris 11 mechine to that machine using the ip filter. I give ipnat.conf configuration like this: rdr net0 0.0.0.0/0 port 1428 -> 10.1.18.178 port 22 but the response appeared when I tried to remote is connection time out, but if I redirect to a solaris 11 machine itself, the configuration is running well. I've enabled IP forwarding on the system root@solaris11:/etc/ipf# ndd -get /dev/ip ip_forwarding 1 root@solaris11:/etc/ipf# routeadm Configuration Current Current Option Configuration System State --------------------------------------------------------------- IPv4 routing enabled enabled IPv6 routing disabled disabled IPv4 forwarding enabled enabled IPv6 forwarding disabled disabled root@solaris11:/etc/ipf# ipadm show-prop PROTO PROPERTY PERM CURRENT PERSISTENT DEFAULT POSSIBLE ipv4 forwarding rw on on off on,off is there any configuration that I missed?

    Read the article

  • PID:4 using Port 80

    - by CyberOPS
    I was trying to install Zend Server CE on my computer but when I got to the point were I need to choose the port for my Web Server it says: "Web Server Port: 80 Occupied". So I decided to check what is using Port 80 with CMD by typing: "netstat -o -n -a | findstr 0.0:80": TCP 0.0.0.0:80 0.0.0.0:0 LISTENING 4 I check for PID:4 in Task Manager's Processes and Services. Seems PID 4 is "System". So, what I want to know is how can I stop "System" (PID:4) from using Port 80? INFO: I am using: Windows 7 64bit; Zend Server CE 5.5.0

    Read the article

  • Port forwarding for Rsync

    - by malfist
    Every port on my server is blocked except port 222 which is were ssh connects too. This server is pretty much a backup server, and I have my clients rsync to it. I do this by using ssh's port forwarding (-P 222 -L 873:myserver.com:873), however, I want to do this with just using the rsync command. Is that possible?

    Read the article

  • Port knocking via SSH tunnels

    - by j0ker
    I have a server running in my university's internal network. There is only one SSH daemon running which is secured by port knocking with knockd. Works fine if I try to connect from within the internal network. But since the server has no external IP, I have to tunnel into the internal network every time I want to access the server from outside. And since tunneling only works for a single port I cannot do the port knocking as easily as from an internal client. In fact, I don't get it to work at all. What I'm trying is opening tunnels for all the different ports that have to be knocked. Then I send TCP-SYN packets into the tunnels. But that doesn't work even for a single port. If I establish the tunnel on the first port in the knock sequence and send a packet through it, it doesn't reach the server. There is no entry in the log file of knockd, while there should be something like 123.45.67.89: openSSH: Stage 1 (as shown with internal knocks). So I guess, the problem doesn't exist within my knocking script but is a more general one. Are there any known problems with what I'm trying to do? Is it even possible or am I missing something? Thanks in advance!

    Read the article

  • SSH: Port Forwarding, Firewalls, & Plesk

    - by Kian Mayne
    I edited my SSH configuration to accept connections on Port 213, as it was one of the few ports that my work firewall allows through. I then restarted sshd and everything was going well. I tested the ssh server locally, and checked the sshd service was listening on port 213; however, I still cannot get it to work outside of localhost. PuTTY gives a connection refused message, and some of the sites that allow check of ports I tried said the port was closed. To me, this is either firewall or port forwarding. But I've already added inbound and outbound exceptions for it. Is this a problem with my server host, or is there something I've missed? My full SSH config file, as requested: # $OpenBSD: sshd_config,v 1.73 2005/12/06 22:38:28 reyk Exp $ # This is the sshd server system-wide configuration file. See # sshd_config(5) for more information. # This sshd was compiled with PATH=/usr/local/bin:/bin:/usr/bin # The strategy used for options in the default sshd_config shipped with # OpenSSH is to specify options with their default value where # possible, but leave them commented. Uncommented options change a # default value. Port 22 Port 213 #Protocol 2,1 Protocol 2 #AddressFamily any #ListenAddress 0.0.0.0 #ListenAddress :: # HostKey for protocol version 1 #HostKey /etc/ssh/ssh_host_key # HostKeys for protocol version 2 #HostKey /etc/ssh/ssh_host_rsa_key #HostKey /etc/ssh/ssh_host_dsa_key # Lifetime and size of ephemeral version 1 server key #KeyRegenerationInterval 1h #ServerKeyBits 768 # Logging # obsoletes QuietMode and FascistLogging #SyslogFacility AUTH SyslogFacility AUTHPRIV #LogLevel INFO # Authentication: #LoginGraceTime 2m #PermitRootLogin yes #StrictModes yes #MaxAuthTries 6 #RSAAuthentication yes #PubkeyAuthentication yes #AuthorizedKeysFile .ssh/authorized_keys # For this to work you will also need host keys in /etc/ssh/ssh_known_hosts #RhostsRSAAuthentication no # similar for protocol version 2 #HostbasedAuthentication no # Change to yes if you don't trust ~/.ssh/known_hosts for # RhostsRSAAuthentication and HostbasedAuthentication #IgnoreUserKnownHosts no # Don't read the user's ~/.rhosts and ~/.shosts files #IgnoreRhosts yes # To disable tunneled clear text passwords, change to no here! #PasswordAuthentication yes #PermitEmptyPasswords no PasswordAuthentication yes # Change to no to disable s/key passwords #ChallengeResponseAuthentication yes ChallengeResponseAuthentication no # Kerberos options #KerberosAuthentication no #KerberosOrLocalPasswd yes #KerberosTicketCleanup yes #KerberosGetAFSToken no # GSSAPI options #GSSAPIAuthentication no GSSAPIAuthentication yes #GSSAPICleanupCredentials yes GSSAPICleanupCredentials yes # Set this to 'yes' to enable PAM authentication, account processing, # and session processing. If this is enabled, PAM authentication will # be allowed through the ChallengeResponseAuthentication mechanism. # Depending on your PAM configuration, this may bypass the setting of # PasswordAuthentication, PermitEmptyPasswords, and # "PermitRootLogin without-password". If you just want the PAM account and # session checks to run without PAM authentication, then enable this but set # ChallengeResponseAuthentication=no #UsePAM no UsePAM yes # Accept locale-related environment variables AcceptEnv LANG LC_CTYPE LC_NUMERIC LC_TIME LC_COLLATE LC_MONETARY LC_MESSAGES AcceptEnv LC_PAPER LC_NAME LC_ADDRESS LC_TELEPHONE LC_MEASUREMENT AcceptEnv LC_IDENTIFICATION LC_ALL #AllowTcpForwarding yes #GatewayPorts no #X11Forwarding no X11Forwarding yes #X11DisplayOffset 10 #X11UseLocalhost yes #PrintMotd yes #PrintLastLog yes #TCPKeepAlive yes #UseLogin no #UsePrivilegeSeparation yes #PermitUserEnvironment no #Compression delayed #ClientAliveInterval 0 #ClientAliveCountMax 3 #ShowPatchLevel no #UseDNS yes #PidFile /var/run/sshd.pid #MaxStartups 10 #PermitTunnel no #ChrootDirectory none # no default banner path #Banner /some/path # override default of no subsystems Subsystem sftp /usr/libexec/openssh/sftp-server

    Read the article

  • Need to open port in a router for two internal PC's

    - by Sergio
    I have two PC's behind a comon internet router and one service running in another network that needs to connect with both PC's through internet using a specific port. To avoid dynamic IP issues I have configured NO-IP accounts in both computers and opened the port in their respective Windows Firewalls. My problem is that when I open the port in the router it only allows me to assign it to one of the computers, but not to both of them. Is there any solution to this?

    Read the article

  • Domain redirection to port on Windows Server 2008

    - by Rauffle
    I have a Windows server running IIS. I wish to run a piece of software that hosts a web interface on a non-standard HTTP port (let's say, port 9999). I have static DNS entries on my router for two FQDNs, both of which direct to the Windows server. I wish to have requests to 'website1' to continue to go to the IIS website on port 80, but requests for 'website2' to instead go to port 9999 to be handled by the other application. How can I accomplish this? Right now I can get to the application by going to 'website1:9999' or 'website2:9999'.

    Read the article

  • Unable to connect to MySQL through port 3306

    - by Ron
    I read the answers about 3306 from a question posted in 2009. I have the same problem, but the answers I read didn't help. Port 3306 is open, even if I stop the windows-firewall, MySQL still can't access it. MySQL is running. I've run netstat firewall xxxxxx and get these results: 3306 TCP Enable MySQL Server and this from netstat -a -n: TCP [::]:3306 [::]:0 LISTENING 0 (I don't understand the [::]) I do have AVG Internet Security running but not the Firewall component. How can I find out what is blocking MySQL from accessing this port? And it's not just this specific port, but any port. I've asked on the MySQL forum, but no one is replying.

    Read the article

  • Allow connection to certain port from specified domain

    - by Scott
    I got two domains, which are pointing on the same IP address, I can use both to connect to the server or certain port (TeamSpeak), the problem is that I would like the only one domain from those two to be working while connecting to a certain port. Eg. example.com points at the 11.22.33.44 -- allow connection to the certain port from this domain. sample.com points at the 11.22.33.44 -- disallow connection to the port specified above from this domain. I know this would be possible for the IP addresses, but would it be possible for the domains?

    Read the article

  • Tcp Port Open by Unknown Service

    - by Singularity
    Running openSUSE 11.2 x86_64. Here's what a nmap of my IP provides: PORT STATE SERVICE 23/tcp open telnet 80/tcp open http 2800/tcp open unknown 8008/tcp open http I would like to know How to view What service is causing Port 2800 to be opened? A few search engine results led me to believe that it is supposedly a port opened by a Trojan called "Theef". If it is indeed a Trojan, what can be done to weed it out? Is my desktop's security compromised?

    Read the article

  • sites now not responding on port 80 [closed]

    - by JohnMerlino
    Possible Duplicate: unable to connect site to different port I was trying to resolve an issue with getting a site running on a different port: unable to connect site to different port But somehow it took out all my other sites. Now even the ones that were responding on port 80 are no longe responding, even though I did not touch the virtual hosts for them. I get this message now: Oops! Google Chrome could not connect to mysite.com However, ping responds: ping mysite.com PING mysite.com (64.135.12.134): 56 data bytes 64 bytes from 64.135.12.134: icmp_seq=0 ttl=49 time=20.839 ms 64 bytes from 64.135.12.134: icmp_seq=1 ttl=49 time=20.489 ms The result of telnet: $ telnet guarddoggps.com 80 Trying 64.135.12.134... telnet: connect to address 64.135.12.134: Connection refused telnet: Unable to connect to remote host

    Read the article

  • threaded serial port IOException when writing

    - by John McDonald
    Hi, I'm trying to write a small application that simply reads data from a socket, extracts some information (two integers) from the data and sends the extracted information off on a serial port. The idea is that it should start and just keep going. In short, it works, but not for long. After a consistently short period I start to receive IOExceptions and socket receive buffer is swamped. The thread framework has been taken from the MSDN serial port example. The delay in send(), readThread.Join(), is an effort to delay read() in order to allow serial port interrupt processing a chance to occur, but I think I've misinterpreted the join function. I either need to sync the processes more effectively or throw some data away as it comes in off the socket, which would be fine. The integer data is controlling a pan tilt unit and I'm sure four times a second would be acceptable, but not sure on how to best acheive either, any ideas would be greatly appreciated, cheers. using System; using System.Collections.Generic; using System.Text; using System.IO.Ports; using System.Threading; using System.Net; using System.Net.Sockets; using System.IO; namespace ConsoleApplication1 { class Program { static bool _continue; static SerialPort _serialPort; static Thread readThread; static Thread sendThread; static String sendString; static Socket s; static int byteCount; static Byte[] bytesReceived; // synchronise send and receive threads static bool dataReceived; const int FIONREAD = 0x4004667F; static void Main(string[] args) { dataReceived = false; readThread = new Thread(Read); sendThread = new Thread(Send); bytesReceived = new Byte[16384]; // Create a new SerialPort object with default settings. _serialPort = new SerialPort("COM4", 38400, Parity.None, 8, StopBits.One); // Set the read/write timeouts _serialPort.WriteTimeout = 500; _serialPort.Open(); string moveMode = "CV "; _serialPort.WriteLine(moveMode); s = null; IPHostEntry hostEntry = Dns.GetHostEntry("localhost"); foreach (IPAddress address in hostEntry.AddressList) { IPEndPoint ipe = new IPEndPoint(address, 10001); Socket tempSocket = new Socket(ipe.AddressFamily, SocketType.Stream, ProtocolType.Tcp); tempSocket.Connect(ipe); if (tempSocket.Connected) { s = tempSocket; s.ReceiveBufferSize = 16384; break; } else { continue; } } readThread.Start(); sendThread.Start(); while (_continue) { Thread.Sleep(10); ;// Console.WriteLine("main..."); } readThread.Join(); _serialPort.Close(); s.Close(); } public static void Read() { while (_continue) { try { //Console.WriteLine("Read"); if (!dataReceived) { byte[] outValue = BitConverter.GetBytes(0); // Check how many bytes have been received. s.IOControl(FIONREAD, null, outValue); uint bytesAvailable = BitConverter.ToUInt32(outValue, 0); if (bytesAvailable > 0) { Console.WriteLine("Read thread..." + bytesAvailable); byteCount = s.Receive(bytesReceived); string str = Encoding.ASCII.GetString(bytesReceived); //str = Encoding::UTF8->GetString( bytesReceived ); string[] split = str.Split(new Char[] { '\t', '\r', '\n' }); string filteredX = (split.GetValue(7)).ToString(); string filteredY = (split.GetValue(8)).ToString(); string[] AzSplit = filteredX.Split(new Char[] { '.' }); filteredX = (AzSplit.GetValue(0)).ToString(); string[] ElSplit = filteredY.Split(new Char[] { '.' }); filteredY = (ElSplit.GetValue(0)).ToString(); // scale values int x = (int)(Convert.ToInt32(filteredX) * 1.9); string scaledAz = x.ToString(); int y = (int)(Convert.ToInt32(filteredY) * 1.9); string scaledEl = y.ToString(); String moveAz = "PS" + scaledAz + " "; String moveEl = "TS" + scaledEl + " "; sendString = moveAz + moveEl; dataReceived = true; } } } catch (TimeoutException) {Console.WriteLine("timeout exception");} catch (NullReferenceException) {Console.WriteLine("Read NULL reference exception");} } } public static void Send() { while (_continue) { try { if (dataReceived) { // sleep Read() thread to allow serial port interrupt processing readThread.Join(100); // send command to PTU dataReceived = false; Console.WriteLine(sendString); _serialPort.WriteLine(sendString); } } catch (TimeoutException) { Console.WriteLine("Timeout exception"); } catch (IOException) { Console.WriteLine("IOException exception"); } catch (NullReferenceException) { Console.WriteLine("Send NULL reference exception"); } } } } }

    Read the article

  • weird characters displayed during serial communication OSX

    - by nemo
    I have tried communicating via serial (OSX w/ prolific drivers - USB RS232 adapter - Tx,Rx and GND pins on device serial ttl port) to a device and done so successfully using screen /dev/tty.usbserial 115200 8N1 I get to log in and use it as if I was SSH or TelNetted in... However whenever I try to go into system recovery mode (holding CTRL+1) while the device is powering on, it starts displaying weird characters and until I close the screen session it will continue showing weird characters: Of course when we tried doing the same thing on my boss' macbook running windows and PuTTY and everything worked fine, even in system recovery mode; characters were displayed properly. What gives? Id like to learn the intuition to use because up till now I concluded that since I can bot into the system and see characters normally everything about the connection should be fine and its must have been the recovery partition that was broken. This was wrong of course... Niko

    Read the article

  • Reading Binary data from a Serial Port.

    - by rross
    I previously have been reading NMEA data from a GPS via a serial port using C#. Now I'm doing something similar, but instead of GPS from a serial. I'm attempting to read a KISS Statement from a TNC. I'm using this event handler. comport.DataReceived += new SerialDataReceivedEventHandler(port_DataReceived); Here is port_DataReceived. private void port_DataReceived(object sender, SerialDataReceivedEventArgs e) { string data = comport.ReadExisting(); sBuffer = data; try { this.Invoke(new EventHandler(delegate { ProcessBuffer(sBuffer); })); } catch { } } The problem I'm having is that the method is being called several times per statement. So the ProcessBuffer method is being called with only a partial statment. How can I read the whole statement?

    Read the article

  • Serial port determinism

    - by Matt Green
    This seems like a simple question, but it is difficult to search for. I need to interface with a device over the serial port. In the event my program (or another) does not finish writing a command to the device, how do I ensure the next run of the program can successfully send a command? Example: The foo program runs and begins writing "A_VERY_LONG_COMMAND" The user terminates the program, but the program has only written, "A_VERY" The user runs the program again, and the command is resent. Except, the device sees "A_VERYA_VERY_LONG_COMMAND," which isn't what we want. Is there any way to make this more deterministic? Serial port programming feels very out-of-control due to issues like this.

    Read the article

  • Recommendation for serial communications in Access 2007

    - by bglenn
    I need to communicate with a bar code scanner connected over a serial port in Microsoft Access. In older versions of Access I was able to use a wrapper around MSCOMM32.ocx that no longer seems to work. I can't use wedge communication because I need to use ACK/NACK which is only supported through the RS232 interface and I need to send messages to the scanner, which is also only supported through the RS232 interface. Are there any controls in widespread use that support serial communication in Access 2007? EDIT: In case anyone comes across this, the newest version of MSCOMM32.ocx (I believe dated 3/09) still works fine as of this writing. It is older versions of MSCOMM32.ocx that do not work.

    Read the article