Search Results

Search found 59558 results on 2383 pages for 'time travel'.

Page 5/2383 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • Start Time & Calculated Column Wonkiness in a SharePoint Event Calendar

    - by _zekeMouseOver
    I was creating some custom rollups on some of our event calendars and came across a very odd bug when trying to grab only the date component of the built-in Start Time field. One's first inclination will be to create a calculated column and give it the formula... =[Start Time]... and then assign its output type to be "Date Only." This works well until a user adds an All Day Event. For reasons unexplainable, the All Day Event flag causes your =[Start Time] to display the date minus one day. Here is an example of this in action:  Start Date and Time, Duration, Start Date Value and Start Day are all calculated fields. Notice how the Start Date and Time (=[Start Time]) is reporting 6:00PM of the previous day. The Start Date Value (=[Start Time] - Output Type: Number) confirms this (.75 = 6:00 PM.) Curiously enough, the Duration (=[End Time]-[Start Time]) is properly reporting the duration between 12:00AM and 11:59PM. Why? I don't know. Perhaps it's somehow bound to the regional settings on the site, but I'm not interested in changing a global site setting for the sake of one calculated field.With this information at our disposal, our calculated column to display the date part of the start date needs to be modified to add one day to the [Start Time] field if an All Day Event is selected. To determine this, we use the Duration above to assume the item is an all-day event and change our formula to be:=IF(TEXT(([End Time]-[Start Time])-TRUNC(([End Time]-[Start Time]),0),"0.000000000")="0.999305556",[Start Time] + 1, [Start Time])This will work, but what happens when the user de-selects the "All Day Event" checkbox? The duration stays the same, but all other values begin reporting the correct time: Since our formula above is strictly based on an expected duration, it will add one to the correct date, causing the date 5/11/2010 to appear. Notice though that the raw value of the start time (in this case) is a non-fractional number (40,308) whereas the all-day event was being represented as 6:00 PM (.75) of the previous day. We can use this to add one more nested branch of logic to our calculation:=IF(TEXT(([End Time]-[Start Time])-TRUNC(([End Time]-[Start Time]),0),"0.000000000")="0.999305556",IF([Start Time]=ROUND([Start Time],0),[Start Time],[Start Time]+1),[Start Time]) I feel somewhat... dirty about having to resort to this kind of calculation in what SHOULD have been a simple =[Start Time] to extract the date part of the Start Time field, but there you have it. Make sure to shower extra longer after having used it.

    Read the article

  • Finding direction of travel in a world with wrapped edges

    - by crazy
    I need to find the shortest distance direction from one point in my 2D world to another point where the edges are wrapped (like asteroids etc). I know how to find the shortest distance but am struggling to find which direction it's in. The shortest distance is given by: int rows = MapY; int cols = MapX; int d1 = abs(S.Y - T.Y); int d2 = abs(S.X - T.X); int dr = min(d1, rows-d1); int dc = min(d2, cols-d2); double dist = sqrt((double)(dr*dr + dc*dc)); Example of the world : : T : :--------------:--------- : : : S : : : : : : T : : : :--------------: In the diagram the edges are shown with : and -. I've shown a wrapped repeat of the world at the top right too. I want to find the direction in degrees from S to T. So the shortest distance is to the top right repeat of T. but how do I calculate the direction in degreed from S to the repeated T in the top right? I know the positions of both S and T but I suppose I need to find the position of the repeated T however there more than 1. The worlds coordinates system starts at 0,0 at the top left and 0 degrees for the direction could start at West. It seems like this shouldn’t be too hard but I haven’t been able to work out a solution. I hope somone can help? Any websites would be appreciated.

    Read the article

  • Having trouble with time.sleep

    - by Waterfox
    When I run, for example: print("[",end=" ") time.sleep(1) print("=",end=" ") time.sleep(1) print("=",end=" ") time.sleep(1) print("=",end=" ") time.sleep(1) print("=",end=" ") time.sleep(1) print("=",end=" ") time.sleep(1) print("=",end=" ") time.sleep(1) print("=",end=" ") time.sleep(1) print("=",end=" ") time.sleep(1) print("=",end=" ") time.sleep(1) print("=",end=" ") time.sleep(1) print("]",end=" ") Nothing happens for 10 seconds, then the whole [ = = = = = = = = = = ] appears. How can I prevent that so that it can act as a sort of progress bar?

    Read the article

  • negative time for a ping echo reply

    - by Mario
    I was happily pinging in the net when suddenly: Pinging X with 32 bytes of data: Reply from .235: bytes=32 time=1444ms TTL=41 Reply from .235: bytes=32 time=1767ms TTL=41 Reply from .235: bytes=32 time=1531ms TTL=41 Reply from .235: bytes=32 time=-1198187ms TTL=41 Ping statistics for .235: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 1444ms, Maximum = -1198187ms, Average = 1073443462ms A negative time for the reply. I checked wireshark and it had the same values: Time delta from previous displayed frame: -1198.187867000 seconds Time since reference or first frame: -1179.935038000 seconds I didn't change the time of the machine while pinging. This was made in my local network at home, from a XP VM in windows 7. So I blame the VM (virtualbox). But I was wondering if this strange behaviour (to me) could have a reason, or if any of you have seen this before. Thank you bye.

    Read the article

  • Windows 7 loses correct time zone upon reboot

    - by Android Eve
    I have a standard PC running Windows 7 Ultimate (64-bit). For some reason, it refuses to keep the correct time zone (the BIOS battery is OK) when restarted. Note (1): The Time zone is correct. The "Internet Time" tab also shows "this computer is set to automatically synchronize with 'time.windows.com'. When I click the 'Change settings...' button, the 'Synchronize with an Internet time server' checkbox is checked. Still, upon reboot, the time is skewed by 6 hours... and doesn't correct itself even after waiting hours for this "automatically synchronize" to occur. Note (2): The BIOS time is set to local (i.e. not UTC). When I restart Windows 7 without booting to the other OS installed in dual-boot config (Ubuntu Linux), it seems to correctly remember the time. This may explain immediate time upon reboot, but it doesn't explain why Windows 7 won't automatically 'Synchronize with an Internet time server' even after an hour. Why is this happening and how do I correct this?

    Read the article

  • SQLAuthority News Training and Consultancy and Travel Story of 30 Last 30 Days

    Today’s blog post is not technical as usual. Here, I present a real story, and I also invite you all to share your thoughts or opinions on this post. I am a professional SQL Server Trainer; I also do consultation in the area of the Performance Tuning and Query Optimizations. In any month, I like [...]...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Enabling Hyper-V Integrated Services Time Sync Services versus Internet Time Synchronization

    - by cpuguru
    Should I deselect the "Synchronize with an Internet Time Server" checkbox under the VM's "Date and Time - Internet Time Settings" tab if the "Time Synchronization Service" for a Hyper-V-based Virtual Machine is enabled? One of the Integration Services that Hyper-V provides is the Time Synchronization Service, which can be enabled/disabled by going to a VM's Settings-Integration Services setting in the Management section. I believe this is checked by default. When you install a Windows Server 2008 OS in a VM on the Hyper-V server, it comes with the "Synchronize with an Internet Time Server" option set, pointing to "time.windows.com". I'd think that if the parent Hyper-V server is set to one time server, and the child VM is pointing to a different time server, there would be a momentary blip if the two are not spot on with their times when the synchronization services run. So the question is, which time sync service should I use? I'm assuming not both. And what is the advantage of one over the other? Note: This question assumes that the machines are not joined to a domain. If they were, the machines would also try to update their time against the domain controller with the primary domain controller role too, right? Thanks!

    Read the article

  • Time not propagating to machines on Windows domain

    - by rbeier
    We have a two-domain Active Directory forest: ourcompany.com at the root, and prod.ourcompany.com for production servers. Time is propagating properly through the root domain, but servers in the child domain are unable to sync via NTP. So the time on these servers is starting to drift, since they're relying only on the hardware clock. WHen I type "net time" on one of the production servers, I get the following error: Could not locate a time-server. More help is available by typing NET HELPMSG 3912. When I type "w32tm /resync", i get the following: Sending resync command to local computer The computer did not resync because no time data was available. "w32tm /query /source" shows the following: Free-running System Clock We have three domain controllers in the prod.ourcompany.com subdomain (overkill, but the result of a migration - we haven't gotten rid of one of the old ones yet.) To complicate matters, the domain controllers are all virtualized, running on two different physical hosts. But the time on the domain controllers themselves is accurate - the servers that aren't DCs are the ones having problems. Two of the DCs are running Server 2003, including the PDC emulator. The third DC is running Server 2008. (I could move the PDC emulator role to the 2008 machine if that would help.) The non-DC servers are all running Server 2008. All other Active Directory functionality works fine in the production domain - we're only seeing problems with NTP. I can manually sync each machine to the time source (the PDC emulator) by doing the following: net time \\dc1.prod.ourcompany.com /set /y But this is just a one-off, and it doesn't cause automated time syncing to start working. I guess I could create a scheduled task which runs the above command periodically, but I'm hoping there's a better way. Does anyone have any ideas as to why this isn't working, and what we can do to fix it? Thanks for your help, Richard

    Read the article

  • Weird fluctuating time on a XEN linux guest

    - by Vin-G
    I have a weird problem with some servers here at work. We have a few XEN guests who's current time fluctuates. # date;date;date;date;date;date;date Thu Feb 25 16:00:40 PHT 2010 Thu Feb 25 16:00:48 PHT 2010 Thu Feb 25 16:00:40 PHT 2010 Thu Feb 25 16:00:48 PHT 2010 Thu Feb 25 16:00:40 PHT 2010 Thu Feb 25 16:00:48 PHT 2010 Thu Feb 25 16:00:40 PHT 2010 As seen above, the time fluctuates between 16:00:48 and 16:00:40, which is problematic for us since computing for time differences in some of our scripts becomes inaccurate (ex. what should be a few ms differences becomes some few second differences, and even sometimes, negative differences). The problematic servers are linux guests on a XEN host. The time fluctuates on the guest systems, but it is okay in the host itself. I've ruled out ntpd since this happens irregardless of whether ntpd is running or not on the guest systems. Guest is on full virtualisation. The time on both the host and the guest does match except that the time in the guest fluctuates at about a few seconds from the host's time, and the host time does not fluctuate. /proc/sys/xen/independent_wallclock is 0 in the host and does not exist in the guest. Ntpd service was stopped and disabled. Setting independent_wallclock to 1 in the host has no effect (that is, time still fluctuates in the guest). Though I was not able to restart the guest as it is a production server. Might be able to do that over the weekend. Any ideas on what to check and how to resolve this problem?

    Read the article

  • Changing time or offsetting it in OpenVZ contained server

    - by Milad Naseri
    I am trying to run a VPS, a Debian box contained in an OpenVZ container. Obviously, I cannot use time --set or any such command, as the time must be set via the parent node. The owner of the parent node, however refuses to adjust the time (which is 30 minutes slower than the actual time). All the programs on my system, consequently, now recognized the false time and this throws a wrench in my syncing. Is there a way to possibly change the system time without interference from the container's administrator? Or perhaps, failing that, a way to make the programs "see" the time 30 minutes faster than what is reported by the container?

    Read the article

  • Time randomly changing itself, internet randomly dying

    - by Vee
    Operating System MS Windows 8 Enterprise 64-bit CPU Intel Core i7 2700K @ 3.50GHz 45 °C Sandy Bridge 32nm Technology RAM 8,00 GB Dual-Channel DDR3 @ 800MHz (8-8-8-24) Motherboard ASRock Z77 Extreme4-M (CPUSocket) 40 °C Graphics SMXL2270HD (1920x1080@60Hz) M2094D-PZ (1680x1050@60Hz) 896MB GeForce GTX 275 (CardExpert Technology) 57 °C Hard Drives 466GB FUJITSU MAXTOR STM3500320AS (SATA) 39 °C Optical Drives ASUS DRW-2014L1T Audio High Definition Audio Device Hello everyone, I installed Windows 8 RTM a few weeks ago. It's not my first time installing it, but it's the first time having two annoying problems: 1) Randomly, the system clock changes time all by itself - to fix it I have to open the time window and sync it with the internet. 2) Randomly, internet connection stops working - to fix I have to run troubleshooting. Windows will find a problem with IP on the "Ethernet" connection and fix it. 3) In rare occasions, my PC freezes and I need to restart it (a BSOD once happened, but after that only freezes) How can I permanently solve these problems? This is what I've already tried: Reset Virus scan Stop/reset the Windows Time service Disable/re-enable Windows Time automatic internet sync Change time from BIOS Change motherboard battery

    Read the article

  • Windows CE 6.0 time setting in registry being overrided

    - by JaminSince83
    I have asked this question on stack overflow but its probably better suited here. So I have a Motorola MC3190 Mobile Barcode scanning device with Windows CE 6.0. Now I want to get the device to sync its date/time on boot up with our domain controller using a registry file that I have created. I have used this registry file below to get close to what I require. REG 1 REGEDIT4 [HKEY_LOCAL_MACHINE\Services\TIMESVC] "UserProcGroup"=dword:00000002 "Flags"=dword:00000010 "multicastperiod"=dword:36EE80 "threshold"=dword:5265C00 "recoveryrefresh"=dword:36EE80 "refresh"=dword:5265C00 "Context"=dword:0 "Autoupdate" = dword:1 "server" = "NAMEOFMYSERVER" "ServerRole" = dword:0 "Trustlocalclock" = dword:0 "Dll"="timesvc.dll" "Keep"=dword:1 "Prefix"="NTP" "Index"=dword:0 [HKEY_LOCAL_MACHINE\nls] "DefaultLCID" = dword:00000809 [HKEY_LOCAL_MACHINE\nls\overrides] "LCID" = dword:00000809 [HKEY_LOCAL_MACHINE\Time] @ = "UTC" "TimeZoneInformation"=hex:\ 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,\ 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00 [HKEY_LOCAL_MACHINE\Time Zones] @ = "UTC" [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Clock] "AutoDST" = dword:00000000 Now it gets the correct date and shows the time zone correctly however the time is always 5 hours behind on Eastern Standard Time, which is really annoying. I have researched heavily into this and this question has been asked before here As you will see I have copied what it suggests but it doesnt work. Something is overiding the time which I dont understand enough about to resolve. I cannot find any other setting to get it to set the time correctly. Any help would be greatly appreciated.

    Read the article

  • Correct way to textually report the remaining time on a long running process?

    - by Ryan
    So you have a long running process, perhaps with a progress bar, and you want a text estimate of the remaining time, eg: "5 minutes remaining" "30 seconds remaining" etc. If you don't actually want to report clock time (due to accuracy or resolution or update-rate issues) but want to stick to the text summary, what is the correct paradigm? Is "one minute" left displayed from 0 to 60 seconds? or from 1:00 to 1:59? Say there's 1:35 Left - is that "2 minutes remaining" or "1 minute remaining"? Do you just pare it down to "A few minutes left" when you're less than 3 minutes? What is the preferred (least user-frustrating) method?

    Read the article

  • Remotely sync Time Machine drives

    - by Off Rhoden
    I have an Xserve that runs Time Machine to a local terabyte drive. I also connected my external terabyte drive for a time period and had Time Machine use it to establish the seed data. I plan to take my drive back home with me (out of state) and have the Xserve return to using its local drive for Time Machine. But when I get back home, is there a way to keep my external drive's copy of the Time Machine Backups folder in sync with the Backups folder back on the Xserve? I'm wanting a full copy of the history (makes an awesome remote backup). I've thought of using the unix command rsync. In fact, that's how I had been doing it but I was looking the compactness that Time Machine was able to achieve. Thanks.

    Read the article

  • Automatic time tracking with central server, web reports

    - by user124209
    I need a software for automatic time tracking on Windows. With the following features: It should record time spent using the computer each day. Start time and end time. It should record what programs the employee used and total time for that program for specified period of time. It must have a centralized server that collects and stores all data. It could be a cloud server outside of a company network. It must have a web interface for viewing the monthly reports (the last but the most important requirement!). A nice feature to have would be an automatic generation of timesheets and Mac OS X support. I am looking to use it for a small team, this is not for personal use. Does anybody knows about software with these features?

    Read the article

  • Can't mount time capsule via wi-fi.

    - by Grnmntn
    I have an Apple time capsule, and have been able to back up to it without a problem for the past few months. However, today I found I cannot connect to the time capsule from Finder, though it appears there, when I click "connect as...", it takes a few seconds and then reports connect failed, "the server may not exist or it is not operational at this time. Check the server name or IP address and your network connection and try again". When I check Time Machine, it says the last backup failed because "the backup volume could not be mounted". The strange part is, the time capsule is also my router, and I am able to use the time capsule as a wireless access point without a problem. Any ideas?

    Read the article

  • Can't connect to Apple Time Capsule in home network using Home Plugs from Win 7 Machine

    - by Eugene
    I have the following home network setup with subnet 255.255.255.0 but recently moved my time capsule to a different location when I added a third Home Plug and can no longer ping or map a network drive to it from the Windows 7 Machine. However using Airport Utility on the Windows 7 machine I can manually configure the Time Capsule. Using a Macbook on WIFI Network 1 or 2 - I can backup to the time capsule, so its accessible via both the router wifi network and the time capsule wifi network. The Time Capsule is set to BRIDGE function - ie no NAT or DHCP server enabled. Any bright sparks out there that can help diagnose the problem? Router (192.168.1.254) WIFI Network 1 | | |---- Home Plug one |---- Home Plug Two | |---- Computer A Windows 7 (192.168.1.160) | |---- Printer (192.168.1.69) |---- Home Plug Three | |---- Apple Time Capsule (192.168.1.150) WIFI Network 2 |---- Smart TV (192.168.1.70) | |---- Apple TV (192.168.1.4)

    Read the article

  • Need leading zero for batch script using %time% variable

    - by Ira
    Hi, I came across a bug in my DOS script that uses date and time data for file naming. The problem was I ended up with a gap because the time variable didn't automatically provide leading zero for hour < 10. So running echo %time% gives back: ' 9:29:17.88'. Does anyone know of a way to conditionally pad leading zeros to fix this? More info: My filename set command is: set logfile=C:\Temp\robolog_%date:~-4%%date:~4,2%%date:~7,2%_%time:~0,2%%time:~3,2%%time:~6,2%.log which ends up being: C:\Temp\robolog_20100602_ 93208.log (for 9:23 in the morning). This question is related to this one. Thanks

    Read the article

  • Config Time Service on Server 2008 DC using Group Policy Only

    - by Ed Fries
    I want to configure the Time Service using only GP in a Server 2008 R2 domain. I have created a GP as follows: Computer Config, Policies, Administrative Templates, System, Windows Time Policy: =Global Configuration Settings -Enabled w/ default settings. Computer Config, Policies, Administrative Templates, System, Windows Time Policy,Time Providers: =Configure Windows NTP Client -Enabled w/ default settings. =Enable Windows NTP Client -Enabled w/ default settings. =Enable Windows NTP Server -Enabled w/ default settings. The policy is linked, enforced and applied to Domain Controllers OU. The GP modeling results shows the policy is in effect on the DC (Single DC domain) and the DC is recognized as the PDC emulator. I have run gpupdate /force and logged off/on. The issue is that the DC shows the time source as internal. I understand I can force this at the cmd line using w32tm to set the peer but I would like to understand what is missing in the GP. The default NTP Client GP setting includes time.windows.com,0x9 as the source but it does not appear to be taking effect.

    Read the article

  • Get the equivalent time between "dynamic" time zones

    - by doctore
    I have a table providers that has three columns (containing more columns but not important in this case): starttime, start time in which you can contact him. endtime, final hour in which you can contact him. region_id, region where the provider resides. In USA: California, Texas, etc. In UK: England, Scotland, etc starttime and endtime are time without timezone columns, but, "indirectly", their value has time zone of the region in which the provider resides. For example: starttime | endtime | region_id (time zone of region) | "real" st | "real" et ----------|----------|---------------------------------|-----------|----------- 03:00:00 | 17:00:00 | 1 (EGT => -1) | 02:00:00 | 16:00:00 Often I need to get the list of suppliers whose time range is within the current server time (taking into account the time zone conversion). The problem is that the time zones aren't "constant", ie, they may change during the summer time. However, this change is very specific to the region and not always carried out at the same time: EGT <= EGST, ART <= ARST, etc. The question is: 1. Is it necessary to use a webservice to update every so often the time zones in the regions? Does anyone know of a web service that can serve? 2. Is there a better approach to solve this problem? Thanks in advance. UPDATE I will give an example to clarify what I'm trying to get. In the table providers I found this records: idproviders | starttime | endtime | region_id ------------|-----------|----------|----------- 1 | 03:00:00 | 17:00:00 | 23 (Texas) 2 | 04:00:00 | 18:00:00 | 23 (Texas) If I execute the query in January, with this information: Server time (UTC offset) = 0 hours Texas providers (UTC offset) = +1 hour Server time = 02:00:00 I should get the following results: idproviders = 1 If I execute the query in June, with this information: Server time (UTC offset) = 0 hours Texas providers (UTC offset) = +2 hours (their local time has not changed, but their time zone has changed) Server time = 02:00:00 I should get the following results: idproviders = 1 and 2

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >