Search Results

Search found 1627 results on 66 pages for 'serial'.

Page 50/66 | < Previous Page | 46 47 48 49 50 51 52 53 54 55 56 57  | Next Page >

  • "Windows detected a hard drive" issue in Windows 7 x64

    - by Jasiu
    I upgraded to the OCZ-Agility3 120GB from a 60 OCZ Vertex2 SSD. I cloned the drive from the Vertex to the new Agility. Everything seemed to have gone well and have not had any problems. Recently in the passed month I have gotten this error: I downloaded teh OCZToolboxMP and ran the SMART utility and don't see anything wrong: SMART READ DATA ModelNumber : OCZ-AGILITY3 Serial Number : OCZ-Y1945X77438P4NU6 WWN : 5-e8-3a-97 ebea5ba76 Revision: 10 Attributes List 1: SSD Raw Read Error Rate Normalized Rate: 70 total ECC and RAISE errors 5: SSD Retired Block Count Reserve blocks remaining: 100% 9: SSD Power-On Hours Total hours power on: 968 12: SSD Power Cycle Count Count of power on/off cycles: 28 171: SSD Program Fail Count Total number of Flash program operation failures: 0 172: SSD Erase Fail Count Total number of Flash erase operation failures: 0 174: SSD Unexpected power loss count Total number of unexpected power loss: 11 177: SSD Wear Range Delta Delta between most-worn and least-worn Flash blocks: 0 181: SSD Program Fail Count Total number of Flash program operation failures: 0 182: SSD Erase Fail Count Total number of Flash erase operation failures: 0 187: SSD Reported Uncorrectable Errors Uncorrectable RAISE errors reported to the host for all data access: 4145 194: SSD Temperature Monitoring Current: 30 High: 30 Low: 30 195: SSD ECC On-the-fly Count Normalized Rate: 120 196: SSD Reallocation Event Count Total number of reallocated Flash blocks: 100 201: SSD Uncorrectable Soft Read Error Rate Normalized Rate: 120 204: SSD Soft ECC Correction Rate (RAISE) Normalized Rate: 120 230: SSD Life Curve Status Current state of drive operation based upon the Life Curve: 100 231: SSD Life Left Approximate SDD life Remaining: 100% 241: SSD Lifetime writes from host lifetime writes 893 GB 242: SSD Lifetime reads from host lifetime reads 968 GB Does anyone have any ideas of what might be wrong and or how I can go about fixing this? Please let me know if there is other information I can provide. Thanks for your help Windows 7 x64 SP1 AMD Phenom II X4 940 8GB RAM

    Read the article

  • Sparc v440 unable 2 boot after recommended patch install

    - by user100660
    After installing the October 2011 recommended patch bundle on a Solaris 10 the host fails to boot. The output is {0} ok boot SC Alert: Host System has Reset screen not found. keyboard not found. Keyboard not present. Using ttya for input and output. Sun Fire V440, No Keyboard Copyright 1998-2003 Sun Microsystems, Inc. All rights reserved. OpenBoot 4.10.10, 8192 MB memory installed, Serial #54744555. Ethernet address 0:3:ba:43:55:eb, Host ID: 834355eb. Rebooting with command: boot Boot device: /pci@1f,700000/scsi@2/disk@0,0:a File and args: \ Evaluating: Out of memory Warning: Fcode sequence resulted in a net stack depth change of 1 Evaluating: Evaluating: The file just loaded does not appear to be executable. {3} ok If I do a boot -F failsafe the host come up and I'm able to mount the root device (ufs on /dev/dsk/c1t0d0s0) and nothing appears broken, i.e I can see the logfiles from the patch install etc. Root device still have 1GB+ free. Only 2 kernel patches was installed from the patch bundle: 144500-19 & 147440-02. Any hints how to debug it further, etc.

    Read the article

  • Installing SATA dvd burner on machine with no spare SATA ports/connectors

    - by Faheem Mitha
    Greetings. I have the following motherboard Tyan Thunder K8WE S2895A2NRF Motherboard - extended ATX - nForce Pro 2200/2050 - Socket 940 - UDMA133, Serial ATA-300 (RAID) - 2 x Gigabit Ethernet - FireWire - 6-1 channel audio This is part of a computer that was assembled in the winter of 2006/2007. The user manual says the following with regard to SATA Integrated SATAII Generation 1 Controllers (from NForce Professional 2200) Two integrated dual port SATA II controllers Four SATA connectors support up to four drives 3 Gb/s per direction per channel NvRAID v2.0 support Supports RAID 0, 1, 0+1 and JBOD. I just purchased a SATA DVD burner. Here is the page for the product http://www.amazon.ca/gp/product/B002QGDWLK/ The problem I am facing is that I already have 4 SATA drives installed. I don't want to remove any of them. However, I want the DVD burner above installed as well. The person I am consulting with here (Bombay, India) tells me that my four available SATA ports are filled, and that my only option is to install a SATA card into the one free PCI slot on the motherboard. However, he says that with this setup I will not be able to boot from the DVD drive. Are these statements correct, and what are my other options if any? Even it the statements in the last para are true, I suppose I could use one of the motherboard connectors/ports there are currently being used with the hard drives with the DVD drive, and use the "add-on" connector with one of the hard drives. Not all the 4 hard drives need to be bootable. BTW, despite having read through http://en.wikipedia.org/wiki/Serial_ATA#Cables.2C_connectors.2C_and_ports I am fuzzy on the differences between connectors, cables and ports. Thanks in advance.

    Read the article

  • How to setup DNS server behind a VPN

    - by Brian
    I want to host some websites behind a VPN and I need some help with the finer points of the configuration. Thus far I've settled on OpenVPN + Bind9 and I want to configure the domains like this: External DNS mail.example.com www.example.com vpn.example.com I want to be able to connect to the vpn using 'vpn.example.com'. Once connected I then want to be able to resolve anything which is '*.vpn.example.com' with the DNS server sitting behind the VPN. I know that OpenVPN can push DNS servers to clients when they connect. I am having trouble though with the DNS config, both internal and external. I've gone through a few tutorials etc. and tried to reason about it myself but I'm not getting anywhere. So my main question would be does the above configuration make sense? If so, any general pointers or examples would be greatly appreciated. Here's what I've tried so far based on this tutorial (I've redacted my domain with example.com). When I try the tests with dig at the end to check the resolution is working it fails. db.vpn.example.com $TTL 15m vpn.example.com. IN SOA ns.vpn.example.com. [email protected]. ( 2009010910 ;serial 900 ;refresh 900 ;retry 900 ;expire 900 ;minimum TTL ) vpn.example.com. IN NS ns.vpn.example.com. ns IN A 192.168.0.2 test IN A 192.168.0.2

    Read the article

  • Splitting Servers into Two Groups

    - by Matt Hanson
    At our organization, we're looking at implementing some sort of informal internal policy for server maintenance. What we're looking at doing is completing maintenance on our entire server pool every two months; each month we'll do half of the servers. What I'm trying to figure out is some way to split the servers into the two groups. Our naming convention isn't much to be desired (but getting better) so by name or number doesn't really work. I can easily take a list of all the servers and split them in two, but with new servers are being added constantly, and old ones retired, that list would be a headache to maintain. I'd like to look at any given server and know if it should have its maintenance done this month or next. For example, it would be nice to look at the serial number. If it started with an even number, then it gets maintenance done on even months and vice-versa. This example won't work though as a little over half of the servers are virtual. Any ideas?

    Read the article

  • Connecting to RDS database from EC2 instance using bind9 CNAME alias

    - by mptre
    I'm trying to get internal DNS up and running on a EC2 instance. The main goal is to be able to define CNAME aliases for other AWS services. For example: Instead of using the RDS endpoint, which might change over time, an alias mysql.company.int can be used instead. I'm using bind9 and here's my config files: /etc/bind/named.conf.local zone "company.int" { type master; file "/etc/bind/db.company.int"; }; /etc/bind/db.company.int ; $TTL 3600 @ IN SOA company.int. company.localhost. ( 20120617 ; Serial 604800 ; Refresh 86400 ; Retry 2419200 ; Expire 604800 ) ; Negative Cache TTL ; @ IN NS company.int. @ IN A 127.0.0.1 @ IN AAAA ::1 ; CNAME mysql IN CNAME xxxx.eu-west-1.rds.amazonaws.com. The dig command ensures me my alias is working as excepted: $ dig mysql.company.int ... ;; ANSWER SECTION: mysql.company.int. 3600 IN CNAME xxxx.eu-west-1.rds.amazonaws.com. xxxx.eu-west-1.rds.amazonaws.com. 60 IN CNAME ec2-yyy-yy-yy-yyy.eu-west-1.compute.amazonaws.com. ec2-yyy-yy-yy-yyy.eu-west-1.compute.amazonaws.com. 589575 IN A zzz.zz.zz.zzz ... As far as I can understand a reverse zone isn't needed for a simple CNAME alias. However when I try to connect to MySQL using my newly created alias the operation is giving me a timeout. $ mysql -uuser -ppassword -hmysql.company.int ERROR 2003 (HY000): Can't connect to MySQL server on 'mysql.company.int' (110) Any ideas? Thanks in advantage!

    Read the article

  • Linux: Force fsck of a read-only mounted filesystem?

    - by Timothy Miller
    I'm developing for a headless embedded appliance, running CentOS 6.2. The user can connect a keyboard, but not a monitor, and a serial console would require opening the case, something we don't want the user to have to do. This all pretty much obviates the possibility of using a recovery USB drive to boot from, unless all it does is blindly reimage the harddrive. I would like to provide some recovery facilities, and I have written a tool that comes up on /dev/tty1 in place of getty to provide these functions. One such function is fsck. I have found out how to remount the root and other file systems read-only. Now that they are read-only, it should be safe to fsck them and then reboot. Unfortunately, fsck complains to me that the filesystems are mounted and refuses to do anything. How can I force fsck to run on a read-only mounted partition? Based on my research, this is going to have to be something obscure. "-f" just means to force repair of a clean (but unmounted) partition. I need to repair a clean or unclean mounted partition. From what I read, this is something "only experts" should do, but no one has bothered to explain how the experts do it. I'm hoping someone can reveal this to me. BTW, I've noticed that e2fsck 1.42.4 on Gentoo will let you fsck a mounted partition, even mounted read-write, but it seems only to do so if fsck is run from a terminal, so it can ask the user if they're sure they want to do something so dangerous. I'm not sure if the CentOS version does the same thing, but it appears that fsck CAN repair a mounted partition, but it flatly refuses to when not run from a terminal. One last-resort option is for me to compile my own hacked fsck. But I'm afraid I'll mess it up in some unexpected way. Thanks! Note: Originally posted here.

    Read the article

  • Fast Ethernet module for Cisco 2620

    - by Kenny Rasschaert
    I have a Cisco 2620 Router. It comes with one fast ethernet port built in (circled in red), and one old AUI ethernet module is installed (circled in blue). I figure I can put a transceiver on the AUI interface to get a second RJ45 connector. What I'd really like to have is a second fast ethernet connector. The ideal candidate to achieve this would be the NM-1FE-TX module. Cisco claims on their website that this module is not suitable for the Cisco 2620 and Cisco 2620XM. It says so in "Table 2 Physical Limitation of Serial Modules per Chassis". Indeed, this module was designed for the 3600 series of routers. I've seen claims on the internet, however, of people having this module on a 2620XM, and it being fully functional. This claim gains some credibility because of the fact that in Cisco's own Packet Tracer software, you can install this module on the 2620XM router. I'm looking for a definitive answer. Will this module work on a Cisco 2620? Is there perhaps another way to get a second fast ethernet port on this device?

    Read the article

  • Setting up Windows SBS 2008 network on Xen

    - by samyboy
    I'm trying to install a Windows SBS 2008 server in a Xen environment. The OS is booting fine. Unfortunately I can't figure out how to set up the network settings. Dom0 is a Debian Lenny hosting around 10 virtual servers. Here are the settings I'm using in the hosted Windows SBS: IP address: 10.20.0.8 Network mask: 255.255.0.0 Gateway: 10.20.0.1 Note that during the installation stage, Windows set the net mask at 255.255.255.0 without letting me choose. Gross. Windows SBS tells me I have a "limited connection". I can't ping the gateway nor any other IP except localhost and it's own IP (10.20.0.8). Here is the Xen config file: kernel = '/usr/lib/xen-3.2-1/boot/hvmloader' builder = 'hvm' memory = '4096' device_model='/usr/lib/xen-3.2-1/bin/qemu-dm' acpi=1 apic=1 pae=1 vcpus=1 name = 'winexchange' # Disks disk = [ 'phy:/dev/wnghosts/exchange-disk,ioemu:hda,w', 'file:/mnt/freespace/ISO/DVD1_Installation.iso,ioemu:hdc:cdrom,r' ] # Networking vif = [ 'mac=00:16:3E:0A:D0:1B, type=ioemu, bridge=xenbr0'] # video stdvga=0 serial='pty' ne2000=0 # Behaviour boot='c' sdl=0 # VNC vfb = [ 'type=vnc' ] vnc=1 vncdisplay=1 vncunused=1 usbdevice='tablet' This config is working with others Windows XP domU's. I tried to change the ne2000 values with 0 and 1 with no effect. I am far from having good Windows administration skills so I guess I definitely need some help on this case. Thanks.

    Read the article

  • Upgrading memory on an IBM Power 710 Express (8231-E2B)

    - by cairnz
    We have a Power 710 Express server that was loaded with 4x4 GB memory on a single riser card. I have replaced the 4 chips with 4x8GB and put in another riser card and loaded it with 4x8GB more for a total of 64GB memory. The firmware is AL730_078. When i power it on, the service processor boots up and i can access the ASMi. From here I can look at "Memory Serial Presence Data" and see that the system in some way detects 8x8 GB. However when i look at Hardware Deconfiguration and specifically Memory Deconfiguration, it is still listed with old values, 16384MB, and claims there are 4x4 chips in the C17 riser. How do i proceed to make the server recognize properly the amount of memory installed? I get a FSPSP04 and B181B50F progress code on booting because (i think) it hasn't been told the memory has changed. It then does not proceed to booting the operating system (VIOS) when turned on. Are there any steps I have overlooked here? Can I do some commands, either on the service processor, or otherwise, to tell the system to configure with the proper amount of memory? PS: This is a stand alone server, not configured with HMC or SDMC.

    Read the article

  • Networking DOS within Windows 7 XP Mode, with a Windows XP/7 Networked Share

    - by theonlylos
    For awhile now, one of my clients has been stuck with Corel Paradox 4.0 (it used to be the biggest database system in the DOS days, until Microsoft released Access in the early 90's) so for awhile I've managed to keep it on life support on Windows XP for a few years, however since switching to Windows 7 x64, I've had to resort to using XP Mode as the sandbox to keep it up and running. While I am able to run Paradox as usual in XP Mode, I'm having a serious issue where if I try connecting the install to the network share (which is located on the Windows 7 portion of the system), Paradox keeps exiting because it says the serial number is invalid. Now, I know for a fact that this is an issue with the virtual loopback adapter and also having the VM linked to the physical ethernet adapter -- and while I have solved this issue before, most of my fixes have been bandages since after a few weeks the issue pops up again. Long story short, I wanted to ask if there is a permanent way to link a DOS program to a network share address. For example, when I try doing \tsclient\paradox (the Windows 7 Address) I keep getting an error saying I need a valid network address. I've tried mapping that folder to various drive letters such as P:\Paradox -- but for some reason that keeps failing over time. For what it's worth, Paradox uses a .SOM file to store the network settings, however it isn't editable in Notepad but rather it's controlled by a wizard in Paradox. But if that extension rings any bells, I'd welcome any insights.

    Read the article

  • Webcam becomes "Unknown Device" after Windows Messenger 2011 is installed

    - by Boris
    I have Sony VAIO VGN-NS290J laptop. I installed Windows 7 Ultimate 64-bit. I was able to find drivers for all hardware without any problems. Recently, I installed Microsoft Windows Live Essentials 2011, i.e. Windows Live Messenger 2011. Ever since that application is running on my computer, my webcam is not recognized by the OS any more. It is listed as the "Unknown Device" and placed in the Universal Serial Bus controllers group in the Device Manager. There don't seem to be any drivers for this webcam. It's a standard Sony Motion Eye web camera and Sony does not offer any drivers for it. There is one application to download that utilizes the camera, but there are no drivers (and the system is showing the same behavior regardless of the presence of the application). It happens from time to time that the webcam becomes recognized by the OS again, after a couple of restarts; but not always. Then it becomes unknown again. I am absolutely positive that this issue is caused by the Windows Live Messenger 2011, because same symptoms caused the same effects before. I wish to be able to continue to use this software, but also to use my webcam. I was wondering if anyone had a similar issue and if there is a way to fix it. Thanks for all the help, I appreciate it. Update: I have discovered a pattern - if the camera goes astray, restarting the machine does not bring it back; but switching the computer off and turning it back on does. Every time! This is getting super complicated :)

    Read the article

  • DNS zone file SPF configuration to support sending mail from multiple servers and gmail

    - by Tauren
    I want to configure SPF on a domain to allow mail to be sent from: the x.com website server (x.com and www.x.com - both at same IP) it's MX servers (smtp.x.com, mx.x.com, mail.x.com) another server that isn't listed as an MX server (somehost.x.com) via gmail using an account that has authenticated use of [email protected] Will this zone file work? If not, what are the problems with it? $ttl 38400 @ IN SOA ns1.x.com. hostmaster.x.com. ( 201003092 ; serial 8H ; refresh 15M ; retry 1W ; expire 1H ) ; minimum @ NS ns1.x.com. @ NS ns2.x.com. @ MX 10 mx.x.com. @ MX 20 smtp.x.com. @ MX 30 mailhost.x.com. ; SPF records @ IN TXT "v=spf1 a mx a:somehost.x.com include:_spf.google.com ~all" mx IN TXT "v=spf1 a -all" smtp IN TXT "v=spf1 a -all" mailhost IN TXT "v=spf1 a -all" Questions: Is _spf.google.com the right thing to include for gmail.com, or is it only for Google Hosted Apps? If only for Google Apps, what should I include to send from gmail.com? If mail shouldn't be sent from anywhere else, is it safe to use -all instead of ~all? Does it make sense to add specific SPF records for each of the mail servers? Any other problems with the zone file? I want to confirm these things before making changes to my zone file. The file has SPF configured basically the same now, just without google.com and somehost, but I want to make sure I won't break things when I change it.

    Read the article

  • How do I run a stable Windows XP kvm guest on Ubuntu 10.04?

    - by Jean-Paul Calderone
    I have three Windows XP guests running on a recently upgraded 64-bit Ubuntu 10.04 system. Occasionally (on the order of once every few days), one of the guests will become non-responsive and the kvm process on the host which is running that guest will start consuming 100% CPU. It will continue to do so until it is killed. When restarted, it will be fine for a while, and then the issue repeats. The kvm command line used to run all three guests is this: /usr/bin/kvm -S -M pc-0.12 -enable-kvm -m 1024 -smp 1 -name bigdog21vmxp1 \ -uuid ea47ff84-125b-16f7-9a4d-a6d0d8bab46a \ -chardev socket,id=monitor,path=/var/lib/libvirt/qemu/bigdog21vmxp1.monitor,server,nowait \ -monitor chardev:monitor \ -localtime \ -boot c \ -drive file=/var/lib/libvirt/images/windowsxp-1.qcow2,if=ide,index=0,boot=on,format=qcow2 \ -net nic,macaddr=54:52:00:02:06:0e,vlan=0,name=nic.0 \ -net tap,fd=58,vlan=0,name=tap.0 \ -chardev pty,id=serial0 \ -serial chardev:serial0 \ -parallel none \ -usb \ -usbdevice tablet \ -vnc 127.0.0.1:1 \ -k en-us \ -vga cirrus \ -soundhw es1370 Why do the systems misbehave this way sometimes? And what configuration can I change in order to fix it? Or, if the problem is due to a bug in kvm, what is the process for isolating a kvm failure so that the developers have a chance of fixing it?

    Read the article

  • Primary zone will not transfer to secondary zone

    - by Matt Beckman
    Using DNS on Windows Server 2008, there is a constant struggle with adding primary and secondary zones. I will add a primary zone to NS1 for a new domain, edit it as needed, and when it's ready add the secondary zone to NS2. However, MOST of the time, the secondary zone remains in an error state, and will never acquire the primary zone data. I have gone back to domains a few weeks after adding them to find out that Windows never propagated the change. Annoying. Anyway, I recently updated SP1 to SP2 thinking this would help, but it hasn't. I added two new domains today, and spent an hour after the secondary zone would just not sync. During that time, the only error in the logs I had seen was for one of them where DNS complained about not being authoritative. In order to eventually resolve the issue, I ended up deleting the primary zone, creating a new primary zone, and hitting "Apply" after each and every field change. For example, after modifying the serial number from "1" to a date appropriate "2010093001", I hit apply, and then the Primary Server (apply), Responsible Person (apply), and finally Name Servers (apply). After I did this, the secondary zone didn't waste any time getting the data. Ideas?

    Read the article

  • Trying to delete a directory stored on a WIndows server, mounted on a mac

    - by AdamG
    I am trying to delete a directory stored on a Windows 2008 R2 server, mounted on a Mac as network home (10.8.5). The directory was created by Safari and stores temporary internet files. I need to be able to delete this folder on logout from a Mac bash script. The Terminal on Mac shows the directory as empty: 36W-FacRm-02:History lwickham$ cd /home/lwickham/Library/Caches/Metadata/Safari/History 36W-FacRm-02:History lwickham$ ls -al total 0 drwx------ 1 lwickham CGPS\Domain Users 264 Nov 8 09:24 . drwx------ 1 lwickham CGPS\Domain Users 264 Nov 8 09:28 .. However, on the Windows server it has a single 0kb file that doesn't start with a "." but yet is invisible to the Mac. E:\FacultyHome2\lwickham\Library\Caches\Metadata\Safari\History>dir Volume in drive E is FacultyUsers2 Volume Serial Number is 8C17-4EF3 Directory of E:\FacultyHome2\lwickham\Library\Caches\Metadata\Safari\History 11/08/2013 09:24 AM <DIR> . 11/08/2013 09:24 AM <DIR> .. 11/07/2013 04:28 PM 0 http?%2F%2Fwww.google.com%2Furl?sa=t&rct= j&q=&esrc=s&source=web&cd=6&ved=0CFsQFjAF&url=http%253A%252F%252Fwww.usbanklocat ions.com%252Fhsbc-bank-usa-96th-street-branch.html&ei=5vR7UtmXEPjfsATe0YCIBA&usg =AFQjCNF9ypKbpYbXRng00FY3W8Y6cF1Tiw&bvm=bv.56146854,d. 1 File(s) 0 bytes 2 Dir(s) 514,231,967,744 bytes free All my attempts to delete the dir from the Mac have failed: 36W-FacRm-02:History lwickham$ rm -fr /home/lwickham/Library/Caches/Metadata/Safari/History/* 36W-FacRm-02:History lwickham$ rm -frd /home/lwickham/Library/Caches/ rm: /home/lwickham/Library/Caches//Metadata/Safari/History: Directory not empty rm: /home/lwickham/Library/Caches//Metadata/Safari: Directory not empty rm: /home/lwickham/Library/Caches//Metadata: Directory not empty rm: /home/lwickham/Library/Caches/: Directory not empty

    Read the article

  • VNC server failed to start CentOS

    - by Shaun
    I followed a tutorial on how to install and get VNCserver to run on CentOS 6 (since freenx isnt supported yet) and I keep getting Starting VNC server: 1:user [FAILED] How do I figure out whats going on here? Im new to Linux/CentOS and im trying to get RDP going so I can step away from SSH as much as possible (you know us Windows users love our pretty GUI's). So, where is the error log at and how do I find it? Or maybe someone else has experienced this and knows the solution based on the simple error given? After running in debug mode, here is my error + . /etc/init.d/functions ++ TEXTDOMAIN=initscripts ++ umask 022 ++ PATH=/sbin:/usr/sbin:/bin:/usr/bin ++ export PATH ++ '[' -z '' ']' ++ COLUMNS=80 ++ '[' -z '' ']' +++ /sbin/consoletype ++ CONSOLETYPE=pty ++ '[' -f /etc/sysconfig/i18n -a -z '' -a -z '' ']' ++ . /etc/profile.d/lang.sh ++ unset LANGSH_SOURCED ++ '[' -z '' ']' ++ '[' -f /etc/sysconfig/init ']' ++ . /etc/sysconfig/init +++ BOOTUP=color +++ RES_COL=60 +++ MOVE_TO_COL='echo -en \033[60G' +++ SETCOLOR_SUCCESS='echo -en \033[0;32m' +++ SETCOLOR_FAILURE='echo -en \033[0;31m' +++ SETCOLOR_WARNING='echo -en \033[0;33m' +++ SETCOLOR_NORMAL='echo -en \033[0;39m' +++ PROMPT=yes +++ AUTOSWAP=no +++ ACTIVE_CONSOLES='/dev/tty[1-6]' +++ SINGLE=/sbin/sushell ++ '[' pty = serial ']' ++ __sed_discard_ignored_files='/\(~\|\.bak\|\.orig\|\.rpmnew\|\.rpmorig\|\.rpmsave\)$/d' + '[' -r /etc/sysconfig/vncservers ']' + . /etc/sysconfig/vncservers ++ VNCSERVERS='1:larry 2:moe 3:curly' ++ VNCSERVERARGS[1]='-geometry 800x600' ++ VNCSERVERARGS[2]='-geometry 640x480' ++ VNCSERVERARGS[3]='-geometry 640x480' + prog='VNC server' + RETVAL=0 + case "$1" in + start + '[' 0 '!=' 0 ']' + . /etc/sysconfig/network ++ NETWORKING=yes ++ HOSTNAME=vps.binaryvisionaries.com ++ DOMAINNAME=server.name ++ GATEWAYDEV=venet0 ++ NETWORKING_IPV6=yes ++ IPV6_DEFAULTDEV=venet0 + '[' yes = no ']' + '[' -x /usr/bin/vncserver ']' + '[' -x /usr/bin/Xvnc ']' + echo -n 'Starting VNC server: ' Starting VNC server: + RETVAL=0 + '[' '!' -d /tmp/.X11-unix ']' + for display in '${VNCSERVERS}' + SERVS=1 + echo -n '1:larry ' 1:larry + DISP=1 + USER=larry + VNCUSERARGS='-geometry 800x600' + runuser -l larry -c 'cd ~larry && [ -r .vnc/passwd ] && vncserver :1 -geometry 800x600' + RETVAL=1 + '[' 1 -eq 0 ']' + break + '[' -z 1 ']' + '[' 1 -eq 0 ']' + failure 'vncserver start' + local rc=1 + '[' color '!=' verbose -a -z '' ']' + echo_failure + '[' color = color ']' + echo -en '\033[60G' + echo -n '[' [+ '[' color = color ']' + echo -en '\033[0;31m' + echo -n FAILED FAILED+ '[' color = color ']' + echo -en '\033[0;39m' + echo -n ']' ]+ echo -ne '\r' + return 1 + '[' -x /usr/bin/plymouth ']' + /usr/bin/plymouth --details + return 1 + echo + '[' 1 -eq 98 ']' + return 1 + exit 1

    Read the article

  • arp requests are sent continuously and my linux machine disconnected to the world

    - by sees
    I have the following problem and really need your help I'm implementing a small server to receive request from client on port 18999(just sample) using TCP socket. When I tested my server by using a lot of requests from a tablet through a router, I got the ARP problem(?) My net work just like: TABLET <------- WIRELESS ROUTER <------- MY SERVER (LINUX) Problems: 1. Can not connect to my Linux any more ( telnet, ping v.v...unreachable) 2. I use serial cable to connect to my Linux machine and use Wiresharp (from Windows) to catch the send message from Linux. It says that Linux keeps sending out continuously every 3 seconds ARP messages like the following: xx:xx:99:77:ff:69 ff:ff:ff:ff:ff:ff ARP 60 Who has 192.168.10.2? Tell 192.168.10.3 In the above message: xx:xx:99:77:ff:69 my Linux MAC address 192.168.10.2 my Tablet address 192.168.10.3 my Linux IP address Can you help me figure out the problem? Or tell me the way to detect the problem and reset the network back to normal (maybe restart Linux but I want to detect problem and restart automatically) UPDATE: 1. The above network works normally if tablet sends messages to my LINUX in normal speed (but also down after 48 hours) 2. The router works again after I unplugged my Linux ethernet cable (RJ45) from router. 3. The wireless network still works ( I can browser the router page from tablet) 4. When I use: ifconfig down then ifconfig up , the Linux restarts (?????????)

    Read the article

  • The bottlenecks of any computer, what to look for?

    - by WebDevHobo
    Whether it is a laptop or a desktop, any computer is made up of several pieces of hardware that communicate with each other. Sending data back and forth to ensure that the user gets the desired results. I have seen some theoretical stuff on computers & hardware, but I wonder how it all comes together. CPU RAM Graphics Card L1 CACHE L2 CACHE L3 CACHE FSB ... And all other things. Which is the biggest bottle neck? Why would a person not want/need a big value in one of those categories in certain situations? P.S.: when reading the specs of the i5 750 processor, I came across this description: In place of the FSB, one or more high speed, point-to-point buses called Quick Path Interconnect (QPI) are used, formerly known as Common Serial Interconnect Bus or CSI. QPI features higher bandwidth than the traditional FSB and is better suited to system scaling. What is this, and how does it compare to FSB? EDIT: I am not planning to buy a computer at all. The goal of this question is to understand the internal relation of various hardware pieces, their specific functions and how they work together. For instance, I have heard to a somewhat higher-than-usual amount of L2/L3 Cache can help speed up your computer. What's up with saying that? Also I forgot to mention Hard-disk RPM.

    Read the article

  • CNAME rule being ignored

    - by Ben
    On a server with Plesk installed I have added a CNAME rule pointing from one of the sites subdomains to an external website. I have checked the named configuration for that domain name and it shows the CNAME however the sub domain just points to the default server page and ignores the CNAME rule. Named has been restarted and I've also run the rvmng reconfigure-vhost command. I edited another server to test this, on cPanel, and it works fine. The conf file for the domain: ; *** Ts file is automatically generated by Plesk *** $TTL 86400 @ IN SOA ns.example.com. cf.example1.com. ( 1292946742 ; Serial 10800 ; Refresh 3600 ; Retry 604800 ; Expire 10800 ) ; Minimum example.com. IN NS ns.example.com. ns.example.com. IN A xx.xxx.xxx.xx example.com. IN A xx.xxx.xxx.xx webmail.example.com. IN A xx.xxx.xxx.xx mail.example.com. IN A xx.xxx.xxx.xx beta.example.com. IN A xx.xxx.xxx.xx ftp.example.com. IN CNAME example.com. www.example.com. IN CNAME example.com. login.example.com. IN CNAME socialize.gigya.com. example.com. IN MX 10 webmail.example.com. You can see the CNAME rule in the file but it just gets ignored? Thanks in advance for any help.

    Read the article

  • Ubuntu lucid, maverick high iowait

    - by netom
    I'm using Ubuntu, and I've got the same problem with Lucid and Maverick. From time to time, especially a few minutes after boot, the iowait goes between 50-100% and the box is unusable. Everything that tries to access the disk freezes. I have the following setup: Hard disk: Model Family: Western Digital Caviar Green family Device Model: WDC WD15EADS-00P8B0 Serial Number: WD-WMAVU0391287 Firmware Version: 01.00A01 User Capacity: 1.500.301.910.016 bytes I have a quad core Intel Core2 Q6600 processor, and 4G of memory. When the high iowait occurs, usually 4 processes are active: kdmflush (two procs) jbd2/dm-0-8 jbd2/db-1-8 and a few more starving user processes of course. I know this from top and iotop. Any suggestions about why this is happening? There are a lot of q/a-s about linux and high iowait, but none of them helped so far, I even tweaked the hard disk not to park the head in every 8 seconds (Load cycle count is 50334!!!!! :o ), but nothing. Problem persists. Thank you in advance.

    Read the article

  • ubuntu not detecting CDdrives

    - by Mirage
    Ihave insatlled ubuntu 10.4 on my compuer with 6 cd drives. Now initiallyi had window server 2008 and i had to install marvel raid sata controller and then my window detected all 6 drives. Now ubuntu is detecting only 3 drives and i have not found marvell drivers for ubuntu bt i have drives for window 2008. Now my question is if i have vrtual machine inside ubuntu using vmware workstation and i install that driver. then can VM dtect thse 6 drives or host has to detect those drives first to make VMs use that Ubuntu shows this thing from terminal *-cdrom:0 description: DVD-RAM writer product: DVDRAM GSA-H10N vendor: HL-DT-ST physical id: 0.0.0 bus info: scsi@0:0.0.0 logical name: /dev/cdrom2 logical name: /dev/cdrw2 logical name: /dev/dvd2 logical name: /dev/dvdrw2 logical name: /dev/scd0 logical name: /dev/sr0 version: JL10 capabilities: removable audio cd-r cd-rw dvd dvd-r dvd-ram configuration: ansiversion=5 status=nodisc *-cdrom:1 description: DVD writer product: DVDRRW GWA-4164B vendor: HL-DT-ST physical id: 0.1.0 bus info: scsi@0:0.1.0 logical name: /dev/cdrom logical name: /dev/cdrw logical name: /dev/dvd logical name: /dev/dvdrw logical name: /dev/scd1 logical name: /dev/sr1 version: 1.01 serial: [HL-DT-STDVDRRW GWA-4164B1.0105/05/12 capabilities: removable audio cd-r cd-rw dvd dvd-r configuration: ansiversion=5 status=nodisc Is t detecting all drives or thise local names just same

    Read the article

  • Extend RAID 1 (HP SmartArray P410i) running Linux

    - by Oliver
    I took over a fairly simple server setup with the following RAID 1 config running Ubuntu 11.10 (Kernel 3.0.0-12-server x86_64): => ctrl all show config Smart Array P410i in Slot 0 (Embedded) (sn: removed) array A (SAS, Unused Space: 1335535 MB) logicaldrive 1 (279.4 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 1 TB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 1 TB, OK) Initially there were two 300GB disks that got replaced by 1TB disks and I now have to extend the logical volume to use that extra space. However, when trying to do so I get the following warning: => ctrl slot=0 ld 1 modify size=max Warning: Extension may not be supported on certain operating systems. Performing extension on these operating systems can cause data to become inaccessible. See ACU documentation for details. Continue? (y/n) Is it safe to say yes or am I at risk of corrupting the file system / loosing data? Rearranging and extending the file system afterwards shouldn't be an issue as I can take the server offline and boot from a gparted live disk. Here's the config of the RAID controller in use: => ctrl all show detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: removed RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: Rev C Firmware Version: 5.12 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: False Drive Write Cache: Disabled SATA NCQ Supported: True And the partition table: Number Start End Size Type File system Flags 1 1049kB 274GB 274GB primary ext4 boot 2 274GB 300GB 25.8GB extended 5 274GB 300GB 25.8GB logical linux-swap(v1)

    Read the article

  • What is the point of PPPoE?

    - by aaa90210
    I am trying to expand my knowledge of networking beyond the basics. I have started reading about PPP, and how it is used in DSL modems with PPPoE and PPPoA. My first impression of PPP was "well that seems pretty similar to Ethernet". They are both data link layer protocols. They both have fields to identify the encapsulated protocol (e.g. IP). They both have related protocols to assign IP addresses (DHCP and NCP). So my first question was "so what's the point of PPP, why not just use Ethernet?". The answer to that was fairly straightforward - Ethernet is not supported over a wide range of media like serial lines, and is a fairly specific technology to LAN's using CAT5 or similar. HOWEVER - then I was reading about PPPoE, and the obvious thought was "well if we are doing something over Ethernet, then Ethernet must be available and in use, so why not just use it?". In other words, PPPoE seems to be encapsulating one data-link layer protocol in another very similar protocol. Why do IP-inside-PPP-inside-Ethernet when we could just be doing IP-inside-Ethernet, and use DHCP rather than NCP to assign the IP address to the home router? Thanks

    Read the article

  • CUPS causes printer to click and doesn't print

    - by Pez Cuckow
    I'm suffering a strange problem with my Cannon iP4850 when trying to use CUPS on a Raspberry Pi (this is not RPi specific, please do not vote to move it). When I plug the printer into my Laptop (OSX) or my Desktop W7 it identifies as a iP4800 and prints perfectly. So I plug it into the Pi (running debian), set it up in CUPS enable sharing and can now see the iP4800 series shared on the network. However if I print to it (using AirPrint etc...); the file gets to CUPS safely (shows in the queue) but when it tries to print the printer clicks (like a loud thunk) 3/4 times and then gives in, with a double amber flashing light. In cups it shows as job completed. Do you know why using the pi and cups would cause what appears to be a hardware fault and what I can do to fix the problem or to provide further debug info? Thanks for your time! Description: Canon iP4800 series Location: Lounge Driver: Canon PIXMA iP4800 - CUPS+Gutenprint v5.2.9 (color, 2-sided printing) Connection: usb://Canon/iP4800%20series?serial=2239B2 Note: I've tried deleting and re-adding the printer to the Laptop, Desktop and PI and the results are always the same Log for plugging in printer and printing (attempting to) something until the printer turned off again pi@pezpi /var/log $ dmesg [ 7284.176336] usb 1-1.2: new high speed USB device number 8 using dwc_otg [ 7284.279703] usb 1-1.2: New USB device found, idVendor=04a9, idProduct=10d5 [ 7284.279750] usb 1-1.2: New USB device strings: Mfr=1, Product=2, SerialNumber=3 [ 7284.279771] usb 1-1.2: Product: iP4800 series [ 7284.279786] usb 1-1.2: Manufacturer: Canon [ 7284.279800] usb 1-1.2: SerialNumber: 2239B2 Setting cups to verbose: Change loglevel in cupsd.conf to debug (or debug2) pi@pezpi /var/log $ sudo vim /etc/cups/cupsd.conf pi@pezpi /var/log $ sudo /etc/init.d/cups restart [ ok ] Restarting Common Unix Printing System: cupsd. pi@pezpi /var/log $ Log from $ /var/log/cups/error_log is at http://pastebin.com/7VZMRMrG (too large to post here) The log contains - in order (deleted the log and then did the beneath) Restarting the cups server Attempting to print a test page x2 Printing from 192.168.1.90 via AirPrint Printing from 192.168.1.90 via Network Print Turning the printer off and on again

    Read the article