Search Results

Search found 1627 results on 66 pages for 'serial'.

Page 52/66 | < Previous Page | 48 49 50 51 52 53 54 55 56 57 58 59  | Next Page >

  • ubuntu VM not detecting CDdrives

    - by Mirage
    Ihave insatlled ubuntu 10.4 on my compuer with 6 cd drives. Now initiallyi had window server 2008 and i had to install marvel raid sata controller and then my window detected all 6 drives. Now ubuntu is detecting only 3 drives and i have not found marvell drivers for ubuntu bt i have drives for window 2008. Now my question is if i have vrtual machine inside ubuntu using vmware workstation and i install that driver. then can VM dtect thse 6 drives or host has to detect those drives first to make VMs use that Ubuntu shows this thing from terminal *-cdrom:0 description: DVD-RAM writer product: DVDRAM GSA-H10N vendor: HL-DT-ST physical id: 0.0.0 bus info: scsi@0:0.0.0 logical name: /dev/cdrom2 logical name: /dev/cdrw2 logical name: /dev/dvd2 logical name: /dev/dvdrw2 logical name: /dev/scd0 logical name: /dev/sr0 version: JL10 capabilities: removable audio cd-r cd-rw dvd dvd-r dvd-ram configuration: ansiversion=5 status=nodisc *-cdrom:1 description: DVD writer product: DVDRRW GWA-4164B vendor: HL-DT-ST physical id: 0.1.0 bus info: scsi@0:0.1.0 logical name: /dev/cdrom logical name: /dev/cdrw logical name: /dev/dvd logical name: /dev/dvdrw logical name: /dev/scd1 logical name: /dev/sr1 version: 1.01 serial: [HL-DT-STDVDRRW GWA-4164B1.0105/05/12 capabilities: removable audio cd-r cd-rw dvd dvd-r configuration: ansiversion=5 status=nodisc Is t detecting all drives or thise local names just same

    Read the article

  • S.M.A.R.T. broken sectors

    - by Jeffrey Vandenborne
    Recently I received my hard drive (LaCie) that I've sent away for warranty, my disk failed, and I used Palimpsest Disk utility to check if anything was wrong in the S.M.A.R.T Status. And it said that there were a few broken sectors. So the next day, I went to the store and told the story. 4 weeks later I actually got my drive back. The first thing I did was plugging it in and starting the disk utility, and weirdly it showed me pretty much the exact same things, even the values of most tests were the same as they were before when my drive broke. The serial number is different though, but it does show a very peculiar value. Now I'm wondering, I'm almost sure it's the exact same drive and it still says I've got broken sectors, does it just say that because it has been cached in the drive somewhere while LaCie DID actually fix it? Or should I run the extended self test (which seems to take hours) first? Also I've tried the smartctl command tool, it says the drive has smart support, but it doesn't show anything, it says that it's enabled, but then it says that it's disabled, picture below The picture of the Disk utility: Thanks in advance

    Read the article

  • Hard Disk Not Counting Reallocated Sectors

    - by MetaNova
    I have a drive that is reporting that the current pending sectors is "45". I have used badblocks to identify the sectors and I have been trying to write zeros to them with dd. From what I understand, when I attempt writing data directly to the bad sectors, it should trigger a reallocation, reducing current pending sectors by one and increasing the reallocated sector count. However, on this disk both Reallocated_Sector_Ct and Reallocated_Event_Count raw values are 0, and dd fails with I/O errors when I attempt to write zeros to the bad sectors. dd works fine, however, when I write to a good sector. # dd if=/dev/zero of=/dev/sdb bs=512 count=1 seek=217152 dd: error writing ‘/dev/sdb’: Input/output error Does this mean that my drive, in some way, has no spare sectors to be used for reallocation? Is my drive just in general a terrible person? (The drive isn't actually mine, I'm helping a friend out. They might have just gotten a cheap drive or something.) In case it is relevant, here is the output of smartctl -i : Model Family: Western Digital Caviar Green (AF) Device Model: WDC WD15EARS-00Z5B1 Serial Number: WD-WMAVU3027748 LU WWN Device Id: 5 0014ee 25998d213 Firmware Version: 80.00A80 User Capacity: 1,500,301,910,016 bytes [1.50 TB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Fri Oct 18 17:47:29 2013 CDT SMART support is: Available - device has SMART capability. SMART support is: Enabled UPDATE: I have run shred on the disk, which has caused Current_Pending_Sector to go to zero. However, Reallocated_Sector_Ct and Reallocated_Event_Count are still zero, and dd is now able to write data to the sectors it was previously unable to. This leads me with several other questions: Why aren't the reallocations being recored by the disk? I'm assuming the reallocation took place as I can now write data directly to the sector and couldn't before. Why did shred cause reallocation and not dd? Does the fact that shred writes random data instead of just zeros make a difference?

    Read the article

  • Syncing two sheets, while being able to hide different data

    - by Joshua
    I'm pretty new to excel- so please bear with me. I have created a spreadsheet to organize gear by serial numbers and by who has it. This list is getting updated multiple times daily as gear shuffles regularly. I have gear that is assigned and unassigned. On the main sheet I have all the data, the way I want it to be organized. What I'm trying to do is duplicate this sheet, so that both sheets automatically keep the same data at all times, but on the first sheet I can hide all the unassigned gear, and view only the assigned gear, and then be able to narrow it down in groups using the hide function heavily. On the second sheet I want to be able to hide all of the assigned gear, and all the columns of gear that have no unassigned gear. End result will be that as gear is moved between individuals or is unassigned entirely, I make that adjustment on one sheet and the data stays the same on both, but the way I view that same sheet is different on both. If I'm making no sense just let me know and I'll try to explain again more clearly. Thanks

    Read the article

  • ipv6 reverse DNS delegation

    - by user1709492
    I currently have 2001:1973:2303::/48 assigned to me and i'll be assigning /64's to customer's I'd like to have 1 zonefile for the /48 where i can essentially point / redirect query to different nameservers. Example ( Desired effect ) 2001:1973:2303:1234::/64 -> ns1.example.com, ns2.example.com 2001:1973:2303:2345::/64 -> ns99.example2.com, ns100.example2.com 2001:1973:2303:4321::/64 -> ns1.cust1.com, ns2.cust1.com Current /48 zonefile $TTL 3h $ORIGIN 3.0.3.2.3.7.9.1.1.0.0.2.ip6.arpa. @ IN SOA ns3.example.ca. ns4.example.ca. ( 2011071030 ; serial 3h ; refresh after 3 hours 1h ; retry after 1 hour 1w ; expire after 1 week 1h ) ; negative caching TTL of 1 hour IN NS ns3.example.ca. IN NS ns4.example.ca. 1234 IN NS ns1.example.com. NS ns2.example.com. 2345 IN NS ns99.example2.com. NS ns100.example2.com. 4321 IN NS ns1.cust1.com. NS ns2.cust1.com. Where am i going wrong ? My request seems simple to me atleast. To put it in terms of firewalling i want to redirect traffic client queries 2001:1973:2303:4321::1 - ns3.example.ca sees the request and redirects the query to ns1.cust1.com - ns1.cust1.com answers the query with omg.itworks.ca ( provided ns1.cust1.com is properly configured.

    Read the article

  • Windows 8 using as a webserver

    - by Jason
    I have a few hobby websites that I currently host on CentOS 6. Apache, mail serving, PHP, MySQL nothing special. In the past I used Windows XP to do this same task, for years, and I was OK. I switched to Linux and for the last few years it has been such a pain. updates break, certain apps only support certain distros without compiling from source. It prevents me from working on my hobby sites more because I am always fixing something. With Windows I locked it down, I run a hardware firewall and packet analyser, kept up on updates and A/V and never had a problem. I dont allow RDC from outside the local LAN, no FTP open, run OpenSSH on an obscure port.. I am considering switching to Windows 8 (since it is a cheaper license now that Windows 7) and running apache, HMailServer, PHP, MySQL, just like my CentOS install. My questions: I am not familiar with Windows 8, can the above be done like XP? No new security restrictions or the OS preventing this from happening? The machine is a Athlon 64-bit X2 with 32GB of RAM. Will Windows 8 see all of the RAM? Technically the machine came with Windows 7, and there is a serial number on it but I am sure I wiped away the Windows 7 recovery partition when I switched to Linux....

    Read the article

  • External HDD incorrectly detected as internal - how change to enable hot swap/eject?

    - by Sam
    Hi All, I have win 7 x64 Home Prem. The HDD is a seagate barracuda, 7200.7 ST3120827AS. 3.5", Serial: 3ms006n6, Firmware: 3.42 (no further updates) NexStar CX External case (drivers installed). I have three drives: WD320 with OS installed WD750 data storage (internal) seagate 120 (external) - connected via esata board connected to sata on motherboard (MSI p43 neo) Tried uninstalling HDD in device manager to no effect. Also the internal WD750 is detected as an external drive and win taskbar icon allows for it to be ejected (unlike the seagate). All drives are configured - Online, Simple, Basic, NTFS, Active, Primary Partition (except c drive). The seagate was previously used as a primary disk with XP operating system so I deleted the volume and created/reformatted (not quick). HDD is no longer "Active". But did not fix problem. Background Originally, I installed win 7 with the bios set to IDE and forgot to install the chipset drivers. Then I changed win 7 to install the AHCI drivers, changed the bios to AHCI and rebooted. Win 7 loaded drivers but WD HDD gave problems/crashed. I installed chipset drivers and latest intell storage matrix software thingie (in safe mode). Everything worked fine after that except for the problem of not corrrectly detecting the external drive] I have noticed that under the driver properties (and similarly in the registry) the two drives are configured differently (e.g. in driver details property capabilities for the WD the value is set to 0000006, CM_DEVCAP_REMOVABLE & EJECTSUPPORTED - whereas the seagate shows 0000080 & CM_DEVCAP_SURPRISEREMOVALOK). Any easy way to configure things? I tried physically swapping the sata connections on the mainboard without success So far I have found that a solution to my problem might be to perform some reg changes: http://superuser.com/questions/12955/how-do-i-remove-the-option-to-eject-sata-drives-from-the-windows-7-tray-icon

    Read the article

  • logfile deleted on Oracle database how to re-create it?

    - by Daniel
    for my database assignment we were looking into 'database corruption' and I was asked to delete the second redo log file which I have done with the command: rm log02a.rdo this was in the $HOME/ORADATA/u03 directory. Now I started up my database using startup pfile=$PFILE nomount then I mounted it using the command alter database mount; now when I try to open it alter database open; it gives me the error: ORA-03113: end-of-file on communication channel Process ID: 22125 Session ID: 25 Serial number: 1 I am assuming this is because the second redo log file is missing. There is still log01a.rdo, but not the one I have deleted. How can I go about recovering this now so that I can open my database again? I have looked into the database created scripts, and it specified the log02a.rdo file to be size 10M and part of group 2. If I do select group#, member from v$logfile; I get: 1 /oradata/student_db/user06/ORADATA/u03/log01a.rdo 2 /oradata/student_db/user06/ORADATA/u03/log02a.rdo 3 /oradata/student_db/user06/ORADATA/u03/log03a.rdo 4 /oradata/student_db/user06/ORADATA/u03/log04a.rdo So it is part of group 2. If I try to add the log02a.rdo file again "already part of the database". If I drop group 2 and then add it again with these commands: ALTER DATABASE ADD LOGFILE GROUP 2 ('$HOME/ORADATA/u03/log02a.rdo') SIZE 10M; Nothing. Supposedly alters the database, but it still won't start up. Any ideas what I can do to re-create this and be able to open my database again?

    Read the article

  • External HDD incorrectly detected as internal - how change to enable hot swap/eject?

    - by Sam
    I have win 7 x64 Home Prem. The HDD is a seagate barracuda, 7200.7 ST3120827AS. 3.5", Serial: 3ms006n6, Firmware: 3.42 (no further updates) NexStar CX External case (drivers installed). I have three drives: WD320 with OS installed WD750 data storage (internal) seagate 120 (external) - connected via esata board connected to sata on motherboard (MSI p43 neo) Tried uninstalling HDD in device manager to no effect. Also the internal WD750 is detected as an external drive and win taskbar icon allows for it to be ejected (unlike the seagate). All drives are configured - Online, Simple, Basic, NTFS, Active, Primary Partition (except c drive). The seagate was previously used as a primary disk with XP operating system so I deleted the volume and created/reformatted (not quick). HDD is no longer "Active". But did not fix problem. Background Originally, I installed win 7 with the bios set to IDE and forgot to install the chipset drivers. Then I changed win 7 to install the AHCI drivers, changed the bios to AHCI and rebooted. Win 7 loaded drivers but WD HDD gave problems/crashed. I installed chipset drivers and latest intell storage matrix software thingie (in safe mode). Everything worked fine after that except for the problem of not corrrectly detecting the external drive] I have noticed that under the driver properties (and similarly in the registry) the two drives are configured differently (e.g. in driver details property capabilities for the WD the value is set to 0000006, CM_DEVCAP_REMOVABLE & EJECTSUPPORTED - whereas the seagate shows 0000080 & CM_DEVCAP_SURPRISEREMOVALOK). Any easy way to configure things? I tried physically swapping the sata connections on the mainboard without success So far I have found that a solution to my problem might be to perform some reg changes: How do I remove the option to eject SATA drives from the Windows 7 tray icon?

    Read the article

  • How does one skip “Windows did not shut down successfully” in Win7-64?

    - by XenonofArcticus
    Migrating an app from an expensive and unreliable dedicated embedded x86 box running WinXP-embedded to COTS hardware (Dell E6410 laptop) running normal Win7-64. At this time, it's not feasible to deploy using Windows 7 embedded. The problem is, that the system is still sort of "embedded". The power could shut off at virtually any time without prior warning. We've stripped the OS down and removed the battery capability so that it will power down as desired. The app never writes to the disk, so it's not like we're going to corrupt anything terribly. The system is essentially idle after our app is up and running (with the exception of some computation, graphics, and TCP/IP and serial communications) so the OS enters a pretty stable state rather quickly. After a power-loss however, it rightly complains that Windows did not shut down successfully and presents the user with the Windows Error Recovery text screen. If left alone, it does eventually move on booting just fine, but we'd like to skip that step if possible. WinXP-embedded is designed to do this automatically, so I know it's possible. I've looked at the Kernel Switches but I didn't see anything documented for "Skip Windows Error Recovery". I've also read extensively on the startup process: http://homepage.ntlworld.com./jonathan.deboynepollard/FGA/windows-nt-6-boot-process.html I know I can disable the auto chkdsk in the registry, but that's not the same thing either. So, how do I streamline the boot process to not hassle the user about a situation that will be the regular normal situation?

    Read the article

  • Unable to ssh in Beagle Bone Black

    - by SamuraiT
    I wanted to install pip onto beagle bone black,and I tried this: /usr/bin/ntpdate -b -s -u pool.ntp.org opkg update && opkg install python-pip python-setuptools then, it threw errors,but Unfortunately, I didn't log that errors. it was occurred a week ago and was't solved yet. I wanted to solve it now and I tried connect by ssh,but I failed. When I ping to beagle bone, it responds, and Cloud9 IDE is working too but not ssh. I don't think this is serious problem since I can connect to beagle bone by other methods: Cloud9 or so. However, to use python on beagle bone, I need to connect by ssh. Before trying to update and install python-pip, I could connect by ssh. Do you have any ideas to solve this connection problem? note I use default OS: Angstrom I don't use SD card. HOST PC is mac, OS.X 10.9 connect by USB serial I checked this but this wasn't helpful http://stackoverflow.com/questions/19233516/cannot-connect-to-beagle-bone-black I could connect by GateOne SSH client, but still unable to connect from terminal.

    Read the article

  • ownership of hard drive recoveery of files Windows 7

    - by Jeff
    Here is the issue. I have an old laptop that died that was running xp. I now have a win 7 laptop. I need to get the files off the old drive. Win 7 will not let me take ownership of the drive. I can runn the comand prompt in regular mode and do a dir on the drive that shows up as Q: drive in regular mode. I gives me the volume as c and the serial number. I can not take ownership in regular mode with the comand prompt or other means. Microsoft site says use safe mode with networking. So I go to safe mode the drive shows up as G: in safe mode. I use the comand prompt Takeown /f G: and get the device is not ready error. I am at a loss. All I want is to retrieve my files from this drive. Any ideas or sugestions. I don't see how you can dir and get some info in one mode and not acces it in another. I have to get ownership and permissions fixed to get in the drive to get my files. Thanks in advance. I might add that I am using a usb3.0 to ide/sata cable adapter. Software came with the device but I can't make heads or tails out of the manual to know if any of the software can help me. The soft ware is PCClone Ex lite, and Clone Drive Soft ware

    Read the article

  • Google Apps: MX records for zonefile

    - by 23tux
    Hi everybody, I have a question about using Google Apps for handling emails. I don't want to set up a whole entire mail system on my server, so I decided to use Google Apps. The ownership of my domain is approved, and now I'm trying to change the MX records in the zone file of my domain. But I think I'm doing wrong, it doesn't work. I want to use mail.mydomain.com as a adress to the mail server for POP, SMTP and IMAP. My zone file looks like this: $TTL 86400 @ IN SOA ns1.first-ns.de. postmaster.robot.first-ns.de. ( 2011011700 ; serial 14400 ; refresh 1800 ; retry 604800 ; expire 86400 ) ; minimum @ IN NS robotns3.second-ns.com. @ IN NS robotns2.second-ns.de. @ IN NS ns1.first-ns.de. @ IN A 111.111.111.111 localhost IN A 127.0.0.1 www IN A 111.111.111.111 ftp IN CNAME www loopback IN CNAME localhost mail IN CNAME @ relay IN CNAME www @ IN MX 10 ALT1.ASPMX.L.GOOGLE.COM. @ IN MX 10 ASPMX3.GOOGLEMAIL.COM. @ IN MX 10 ASPMX2.GOOGLEMAIL.COM. @ IN MX 10 ASPMX.L.GOOGLE.COM. @ IN MX 10 ALT2.ASPMX.L.GOOGLE.COM. I hope someone can figure out, what's wrong with this configuration. When I start a ping on mail.mydomain.org I get an answer from 111.111.111.111 and not from the google server ALT1.ASPMX.L.GOOGLE.COM. thx, tux

    Read the article

  • Trying to delete a directory stored on a Windows server, from on a Mac, containing files created on the Mac, getting "Directory not empty"

    - by AdamG
    I am trying to delete a directory stored on a Windows 2008 R2 server, mounted on a Mac as network home (10.8.5). The directory was created by Safari and stores temporary internet files. I need to be able to delete this folder on logout from a Mac bash script. The Terminal on Mac shows the directory as empty: 36W-FacRm-02:History lwickham$ cd /home/lwickham/Library/Caches/Metadata/Safari/History 36W-FacRm-02:History lwickham$ ls -al total 0 drwx------ 1 lwickham CGPS\Domain Users 264 Nov 8 09:24 . drwx------ 1 lwickham CGPS\Domain Users 264 Nov 8 09:28 .. However, on the Windows server it has a single 0kb file that doesn't start with a "." but yet is invisible to the Mac. E:\FacultyHome2\lwickham\Library\Caches\Metadata\Safari\History>dir Volume in drive E is FacultyUsers2 Volume Serial Number is 8C17-4EF3 Directory of E:\FacultyHome2\lwickham\Library\Caches\Metadata\Safari\History 11/08/2013 09:24 AM <DIR> . 11/08/2013 09:24 AM <DIR> .. 11/07/2013 04:28 PM 0 http?%2F%2Fwww.google.com%2Furl?sa=t&rct= j&q=&esrc=s&source=web&cd=6&ved=0CFsQFjAF&url=http%253A%252F%252Fwww.usbanklocat ions.com%252Fhsbc-bank-usa-96th-street-branch.html&ei=5vR7UtmXEPjfsATe0YCIBA&usg =AFQjCNF9ypKbpYbXRng00FY3W8Y6cF1Tiw&bvm=bv.56146854,d. 1 File(s) 0 bytes 2 Dir(s) 514,231,967,744 bytes free 9ypKbpYbXRng00FY3W8Y6cF1Tiw&bvm=bv.56146854,d.1 File(s) 0 bytes2 Dir(s) 514,231,967,744 bytes free All my attempts to delete the dir from the Mac have failed: 36W-FacRm-02:History lwickham$ rm -fr /home/lwickham/Library/Caches/Metadata/Safari/History/* 36W-FacRm-02:History lwickham$ rm -frd /home/lwickham/Library/Caches/ rm: /home/lwickham/Library/Caches//Metadata/Safari/History: Directory not empty rm: /home/lwickham/Library/Caches//Metadata/Safari: Directory not empty rm: /home/lwickham/Library/Caches//Metadata: Directory not empty rm: /home/lwickham/Library/Caches/: Directory not empty

    Read the article

  • Trying to Set up SMTP Server on WIndows Server 2012

    - by datc
    I'm working on a website, and I need to test the functionality of sending email messages from ASP.NET, something like this: Dim msg As New MailMessage("email1", "email2") msg.Subject = "Subject"<br> msg.IsBodyHtml = True<br> msg.Body = "Click <a href='site'>here</a>." Dim client As SmtpClient = New SmtpClient() client.Host = "My-Server"<br> client.Port = 25<br> client.DeliveryMethod = SmtpDeliveryMethod.Network<br> client.Send(msg) This is running from a Windows 8 workstation. I've installed SMTP server on my Windows Server 2012 machine. The mail shows up in the mailroot/Queue folder and sits there, eventually getting deposited into Badmail. Now I have AT&T U-verse at home, and a few devices connected to the gateway, including let's call it "My-Server." When I run SmtpDiag from say, datc@... to [email protected] I get SOA serial number match passed, Local DNS (99-135-60-233.lightspeed.bcvloh.sbcglobal.net) & Remote DNS (hotmail.com) tests *not* passed, and ultimately, Connecting to the server failed. Error: 10060. Failed to submit mail to mx2.hotmail.com error. When I set My-Server's IP to static and equal to the external IP, 99.135.60.233, and again run SmtpDiag, I get SOA, Local DNS, and Remote DNS tests passed, but the same 10060 error. Same for yahoo.com, gmail.com, and so forth. Is it my ISP's job to fix this? Some PTR record missing somewhere? Is it at all possible to have a home-based SMTP server? All I want is to test my email code. Perhaps, my IP address is just not "trusted" somehow. Thanks.

    Read the article

  • Backtrack, Wi-Fi not working

    - by hradecek
    I've installed Backtrack 5R3 KDE, and I realized that my wireless is not working, but wired is working fine. Here's the lshw output: *-network description: Ethernet interface product: RTL8101E/RTL8102E PCI Express Fast Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:02:00.0 logical name: eth0 version: 05 serial: 04:7d:7b:b7:46:f8 size: 100MB/s capacity: 100MB/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=full firmware=rtl_nic/rtl8105e-1.fw ip=192.168.2.2 latency=0 link=yes multicast=yes port=MII speed=100MB/s resources: irq:42 ioport:2000(size=256) memory:f0404000-f0404fff memory:f0400000-f0403fff lspci output: 00:00.0 Host bridge: Intel Corporation 2nd Generation Core Processor Family DRAM Controller (rev 09) 00:02.0 VGA compatible controller: Intel Corporation 2nd Generation Core Processor Family Integrated Graphics Controller (rev 09) 00:14.0 USB Controller: Intel Corporation Panther Point USB xHCI Host Controller (rev 04) 00:16.0 Communication controller: Intel Corporation Panther Point MEI Controller #1 (rev 04) 00:1a.0 USB Controller: Intel Corporation Panther Point USB Enhanced Host Controller #2 (rev 04) 00:1b.0 Audio device: Intel Corporation Panther Point High Definition Audio Controller (rev 04) 00:1c.0 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 1 (rev c4) 00:1c.1 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 2 (rev c4) 00:1d.0 USB Controller: Intel Corporation Panther Point USB Enhanced Host Controller #1 (rev 04) 00:1f.0 ISA bridge: Intel Corporation Panther Point LPC Controller (rev 04) 00:1f.2 SATA controller: Intel Corporation Panther Point 6 port SATA AHCI Controller (rev 04) 00:1f.3 SMBus: Intel Corporation Panther Point SMBus Controller (rev 04) 02:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8101E/RTL8102E PCI Express Fast Ethernet controller (rev 05)

    Read the article

  • how to get ip address of a PPP(Point-to-Point Protocol) network interface?

    - by Xsmael
    I have a Linux machine with two network interfaces, and I'd like to get the IP address of the PPP interface w1g1 but it doesn't show up in ifconfig. There is a public IP on the PPP interface, but there is no internet connection, I'm trying to troubleshoot but I need to get the IP address of the interface and I can't. ifconfig : eth0 Link encap:Ethernet HWaddr 00:30:48:8D:F0:2C inet addr:192.168.2.254 Bcast:192.168.2.255 Mask:255.255.255.0 inet6 addr: fe80::230:48ff:fe8d:f02c/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:9970 errors:0 dropped:567 overruns:0 frame:0 TX packets:4338 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:100 RX bytes:1441024 (1.3 MiB) TX bytes:915814 (894.3 KiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:675 errors:0 dropped:0 overruns:0 frame:0 TX packets:675 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:50659 (49.4 KiB) TX bytes:50659 (49.4 KiB) w1g1 Link encap:Point-to-Point Protocol UP POINTOPOINT RUNNING NOARP MTU:240 Metric:1 RX packets:748994 errors:0 dropped:0 overruns:0 frame:0 TX packets:748992 errors:0 dropped:0 overruns:0 carrier:3 collisions:0 txqueuelen:100 RX bytes:179758560 (171.4 MiB) TX bytes:179758080 (171.4 MiB) Interrupt:177 Memory:f881c400-f881e3ff w1g1 is connected to a modem by an RJ45<-Serial cable and the modem is connected to the phone line. The modem is a NOKIA DNT2Mi you can see it here Routing table : 192.168.2.0/24 dev eth0 proto kernel scope link src 192.168.2.254 169.254.0.0/16 dev eth0 scope link default via 192.168.2.180 dev eth0

    Read the article

  • How to automatically start VM created by virt-manager?

    - by Jeff Shattock
    I have created a virtual machine with virt-manager that runs on kvm/qemu. The machine works well when started through virt-manager. However, I would like to be able to start and stop the VM through a script in init.d, so that it comes up and down along with the host. I need to have virt-manager show that the machine is running, and to be able to connect to its console through there. When I use the command line that is produced by running ps -eaf | grep kvm after starting the vm through virt-manager, I get some console messages about redirected character devices, but the machine does start and runs properly. However, I do not get any indication from virt-manager that it has started. How can I modify the command line to get virt-manager to pick up the running VM? Is there anything else about the command line that should change when starting outside of virt-manager? Command line is (slightly reformatted for readability): /usr/bin/kvm -S -M pc-0.12 -enable-kvm -m 512 -smp 1 -name BORON \ -uuid fa7e5fbd-7d8e-43c4-ebd9-1504a4383eb1 \ -chardev socket,id=monitor,path=/var/lib/libvirt/qemu/BORON.monitor,server,nowait \ -monitor chardev:monitor -localtime -boot c \ -drive file=/dev/FS1/BORON,if=ide,index=0,boot=on,format=raw \ -net nic,macaddr=52:54:00:20:0b:fd,vlan=0,name=nic.0 \ -net tap,fd=41,vlan=0,name=tap.0 -chardev pty,id=serial0 -serial chardev:serial0 \ -parallel none -usb -usbdevice tablet -vnc 127.0.0.1:1 -k en-us -vga cirrus

    Read the article

  • Getting dwl-g122 to work on ubuntu

    - by User1
    I have a USB WiFi adapter, D-Link dwl-g122. I'm running Ubuntu 10.4. My laptop has a built-in wireless card that is connecting fine to the router. I plug in the usb and it never really connects. Here are some details: iwconfig wlan1 IEEE 802.11bg ESSID:"\x0B\xE1..." Mode:Managed Frequency:2.457 GHz Access Point: Not-Associated Tx-Power=19 dBm Retry long limit:7 RTS thr:off Fragment thr:off Power Management:on lshw -c network: *-network:1 description: Wireless interface physical id: 3 logical name: wlan1 serial: 00:13:46:8b:xx:xx capabilities: ethernet physical wireless configuration: broadcast=yes multicast=yes wireless=IEEE 802.11bg dmesg [ 1096.814176] wlan1: direct probe to AP xxx (try 1) [ 1096.820960] wlan1: direct probe responded [ 1096.820969] wlan1: authenticate with AP xxx (try 1) [ 1096.823790] wlan1: authenticated [ 1096.823869] wlan1: associate with AP xxx (try 1) [ 1096.827667] wlan1: RX AssocResp from xxx (capab=0x411 status=0 aid=1) [ 1096.827674] wlan1: associated [ 1142.590912] wlan1: deauthenticating from xxx by local choice (reason=3) lsmod|rt2 rt2500usb 19643 0 rt2x00usb 11260 1 rt2500usb rt2x00lib 32133 2 rt2500usb,rt2x00usb mac80211 238896 3 ath5k,rt2x00usb,rt2x00lib cfg80211 148725 4 ath5k,ath,rt2x00lib,mac80211 led_class 3764 3 ath5k,rt2x00lib,sdhci It looks like the driver loads but it doesn't feel like connecting. The behavior is identical even if I blacklist the other wifi card (using an ath5k driver). It's almost like it is using the wrong password or something. Does anyone know what is happening? Is anyone using Ubuntu successful?

    Read the article

  • How to delete a file that contains a backslash in the name under Windows 7?

    - by espinchi
    I want to delete a file named workspaces\google-gson-1.7.1-release.zip Yep, it contains a backslash in the name. Here it is: G:\>dir Z_DRIVE Volume in drive G is samsung Volume Serial Number is 48B9-7E1D Directory of G:\Z_DRIVE 04/06/2012 08:09 PM <DIR> . 04/06/2012 08:09 PM <DIR> .. 05/01/2011 02:21 PM 528,016 workspaces\google-gson-1.7.1-release.zip 1 File(s) 528,016 bytes 2 Dir(s) 88,400,478,208 bytes free The first attempt is to just delete it from the Windows Explorer, but it says it can't find the file. Then, I tried from the command line: G:\>del Z_DRIVE\workspaces\google-gson-1.7.1-release.zip The system cannot find the file specified. And, after researching a bit in the internets, I also tried the following, with no luck: G:\>del \\?\G:\Z_DRIVE\workspaces\google-gson-1.7.1-release.zip The system cannot find the file specified. Other than booting from some Linux CD, is there a way to get rid of this file? Update: also tried the following combinations, but the error is the same: G:\>del "\\?\G:\Z_DRIVE\workspaces\google-gson-1.7.1-release.zip" G:\Z_DRIVE>del workspaces\google-gson-1.7.1-release.zip G:\Z_DRIVE>del "workspaces\google-gson-1.7.1-release.zip" G:\Z_DRIVE>del workspaces*google-gson-1.7.1-release.zip

    Read the article

  • Linksys SFE2000 Interface

    - by boburob
    I have a real problem with a layer 3 Linksys switch. First, every time it looses power, it seems to reset back to an older config. Not only this, but when this happens it looses interface settings on one subnet. This would not be a problem but I am completely unable to get to the interface on the working side. It allows me to log on and then just displays a blank screen. I have tried this on: IE6 IE7 IE8 IE9 Firefox 3.5 Opera Chrome All with the same results, except for Opera, which loads half the interface but nothing I can really use. I really need to get onto this switch so I can sort out routing and VLAN tagged ports, so if anyone has any ideas on either of these issues please let me know ASAP! Thanks! Also, due to its location and my lack of laptops with serial connections I cannot putty into it. UPDATE: Looked into this a bit more and it looks like this model of switch does not save the current config to boot unless you make sure to save it yourself, which explains the first issue, however the broken interface is more worrying!

    Read the article

  • Is it safe to force a dismount to format a volume in Windows?

    - by sammyg
    I am using format command in cmd to format a USB flash drive. M:\>format /FS:FAT32 /Q Required parameter missing - M:\>format M: /FS:FAT32 /Q Insert new disk for drive M: and press ENTER when ready... The type of the file system is FAT32. QuickFormatting 14999M Format cannot run because the volume is in use by another process. Format may run if this volume is dismounted first. ALL OPENED HANDLES TO THIS VOLUME WOULD THEN BE INVALID. Would you like to force a dismount on this volume? (Y/N) y Volume dismounted. All opened handles to this volume are now invalid. Initializing the File Allocation Table (FAT)... Volume label (11 characters, ENTER for none)? Format complete. 14,6 GB total disk space. 14,6 GB are available. 8 192 bytes in each allocation unit. 1 917 823 allocation units available on disk. 32 bits in each FAT entry. Volume Serial Number is E00B-2739 M:\> Is it safe to force a dismount like this, and make the handles invalid?

    Read the article

  • Windows 8 "Upgrade Offer" eligibilty when running the Consumer Preview in a VM?

    - by Dan Harris
    If I have a VM running Windows 8 Consumer/Release Preview, am I allowed to take advantage of the Windows 8 upgrade offer, and install it on that machine? I would have assumed not...as there was never a licensed version of XP SP3 through to Windows 7 installed in that VM. It was a clean installation of the Consumer Preview into a VM. My confusion comes from the notes at the bottom of the download page for the Upgrade offer which states: Offer valid from October 26, 2012 until January 31, 2013 and is for individuals and small businesses needing to upgrade up to five devices. If you are a business customer looking to upgrade more than five devices to Windows 8 Pro, contact your Microsoft partner for more information. To install Windows 8 Pro, customers must be running Windows XP SP3, Windows Vista, Windows 7, Windows 8 Consumer Preview, or Windows 8 Release Preview. I am assuming it's not possible and i'll need to purchase the System Builder edition to install within a VM? My guess is that you can use your downloaded upgrade offer only if you updated Windows 7 to the release preview, and therefore had the Windows 7 license on the machine, I used the serial number from the Microsoft Website when downloading the Release Preview, and did a clean install, so there was never a Windows 7 license on the VM. I have MSDN for development purposes, but I am looking to run in a VM for personal use as well, so my MSDN license is not valid for that particular use.

    Read the article

  • Cannot make bind9 forward DNS query to subdomain unless recursive enabled

    - by PP.
    I am trying to develop my own dynamic DNS. I'm running my own custom DNS for the subdomain on port 5353. ASCII diagram: INET --->:53 Bind 9 --->:5353 node.js | V zone_files I have example.com. The node.js DNS is for dyn.example.com. In my /etc/bind/named.conf.local I have: zone "example.com" { type master; file "/etc/bind/db.com.example"; allow-transfer { zonetxfrsafe; }; }; zone "dyn.example.com" IN { # DYNAMIC type forward; forwarders { 127.0.0.1 port 5353; }; forward only; }; I've even gone so far as to add a NS in my example.com zone file: $TTL 86400 @ IN SOA ns.example.com. hostmaster.example.com. ( 2013070104 ; Serial 7200 ; Refresh 1200 ; Retry 2419200 ; Expire 86400 ) ; Negative Cache TTL ; NS ns ; inet of our nameserver ns A 1.2.3.4 ; NS record for subdomain dyn NS ns When I attempt to get a record from the subdomain server it doesn't get forwarded: dig @127.0.0.1 test.dyn.example.com However if I turn recursive on in /etc/bind/named.conf.options: options { recursion yes; } .. then I CAN see the request going to the subdomain server. But I don't want recursion yes; in my Bind configuration as it is poor security practice (and allows all-and-sundry requests that are not related to my managed zones). How does one forward (proxy) zone queries for just one zone? Or do I give up on Bind altogether and find a DNS server that can actually forward specific queries?

    Read the article

  • Transfer of ownership of Windows 7

    - by ziggy
    I am thinking of purchasing a copy of Windows 7 via either ebay or GumTree. I am unsure as to how the product key works. A close friend of mine is warning me against buying it from ebay as he is suggesting that once it has been used, the operating system registers itself on microsoft servers using the serial number of the motherboard of the system where it has been installed. This means once installed on one machine you wont be able to install it on another machine. Now i am struggling to believe that an operating system can only be installed on one machine. Can someone please explain exactly how this works. I can see a lot of copies being sold on Ebay which are used. I used the 'Ask a question' option and the majority of the users are saying that i should be able to use it. If someone buys Windows 7 from the shop, installs it on his PC but then decides that he wants to sell it can he not sell it? Will the person buying it not be able to use it? Does the person selling it have to somehow unregister it first? What do i need to look out for if buying it from Ebay? Thanks

    Read the article

< Previous Page | 48 49 50 51 52 53 54 55 56 57 58 59  | Next Page >