  • does the *physical* order/location of drives in a mdadm-managed RAID-10 array matter?

    - by locuse
    i've setup a 4-drive RAID-10 array using mdadm-managed, software-raid on an x86_64 box. it'd up & running and works as expected, cat /proc/mdstat md127 : active raid10 sdc2[2] sdd2[3] sda2[0] sdb2[1] 1951397888 blocks super 1.2 512K chunks 2 far-copies [4/4] [UUUU] bitmap: 9/466 pages [36KB], 2048KB chunk atm the four SATA drives are physically plugged into the motherboard's 1st four SATA ports. i'd like to gather the necessary/complete info for catastrophic recovery. reading starting here, http://neil.brown.name/blog, and the mailing list, i'm not yet completely confident i have it right. i understand 'drive order matters'. is that logical, &/or physical order that matters? if i unplugged the four drives in this array, and plugged them each back into different ports on the motherboard or a pci card, as long as i've changed nothing in software config, will the array correctly auto-re-assemble?

    Read the article

  • iTunes Title Bar is Equal to the Location of the Library file?

    - by Urda
    I have never been able to get a clear answer on why the latest edition of iTunes does this. I have my entire iTunes library located in C:\itunes\ and the library data files inside C:\itunes\!library_info for backup purposes. However when version 9 of iTunes came out it went from having iTunes as the title, to !library_info. Anyway to get around this without moving my data files away? Annoying "feature" if that is what it is. Again Apple support and forums were of no help to me. Anyone have insight on this? System Info: Windows Vista x86 Ultimate, latest updates. iTunes Version 9.0.3.15 Screenshot: http://farm5.static.flickr.com/4072/4414557544_d0b25eb64c_o.jpg Flickr Page: http://www.flickr.com/photos/urda/4414557544/ UPDATE: I put a bounty on this, and would be open to hacking the registry or doing a custom config. Please help me fix my title bar!!! Update2: I would not like to move my library files out of itunes\!library_info to avoid them inter-mingling with my music library.

    Read the article

  • Nginx + PHP-FPM on Centos 6.5 gives me 502 Bad Gateway (fpm error: unable to read what child say: Bad file descriptor)

    - by Latheesan Kanes
    I am setting up a standard LEMP stack. My current setup is giving me the following error: 502 Bad Gateway This is what is currently installed on my server: Here's the configurations I've created/updated so far, can some one take a look at the following and see where the error might be? I've already checked my logs, there's nothing in there (http://i.imgur.com/iRq3ksb.png). And I saw the following in /var/log/php-fpm/error.log file. sidenote: both the nginx and php-fpm has been configured to run under a local account called www-data and the following folders exits on the server nginx.conf global nginx configuration user www-data; worker_processes 6; worker_rlimit_nofile 100000; error_log /var/log/nginx/error.log crit; pid /var/run/nginx.pid; events { worker_connections 2048; use epoll; multi_accept on; } http { include /etc/nginx/mime.types; default_type application/octet-stream; # cache informations about FDs, frequently accessed files can boost performance open_file_cache max=200000 inactive=20s; open_file_cache_valid 30s; open_file_cache_min_uses 2; open_file_cache_errors on; # to boost IO on HDD we can disable access logs access_log off; # copies data between one FD and other from within the kernel # faster then read() + write() sendfile on; # send headers in one peace, its better then sending them one by one tcp_nopush on; # don't buffer data sent, good for small data bursts in real time tcp_nodelay on; # server will close connection after this time keepalive_timeout 60; # number of requests client can make over keep-alive -- for testing keepalive_requests 100000; # allow the server to close connection on non responding client, this will free up memory reset_timedout_connection on; # request timed out -- default 60 client_body_timeout 60; # if client stop responding, free up memory -- default 60 send_timeout 60; # reduce the data that needs to be sent over network gzip on; gzip_min_length 10240; gzip_proxied expired no-cache no-store private auth; gzip_types text/plain text/css text/xml text/javascript application/x-javascript application/xml; gzip_disable "MSIE [1-6]\."; # Load vHosts include /etc/nginx/conf.d/*.conf; } conf.d/www.domain.com.conf my vhost entry ## Nginx php-fpm Upstream upstream wwwdomaincom { server unix:/var/run/php-fcgi-www-data.sock; } ## Global Config client_max_body_size 10M; server_names_hash_bucket_size 64; ## Web Server Config server { ## Server Info listen 80; server_name domain.com *.domain.com; root /home/www-data/public_html; index index.html index.php; ## Error log error_log /home/www-data/logs/nginx-errors.log; ## DocumentRoot setup location / { try_files $uri $uri/ @handler; expires 30d; } ## These locations would be hidden by .htaccess normally #location /app/ { deny all; } ## Disable .htaccess and other hidden files location /. { return 404; } ## Magento uses a common front handler location @handler { rewrite / /index.php; } ## Forward paths like /js/index.php/x.js to relevant handler location ~ .php/ { rewrite ^(.*.php)/ $1 last; } ## Execute PHP scripts location ~ \.php$ { try_files $uri =404; expires off; fastcgi_read_timeout 900; fastcgi_pass wwwdomaincom; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; include fastcgi_params; } ## GZip Compression gzip on; gzip_comp_level 8; gzip_min_length 1000; gzip_proxied any; gzip_types text/plain application/xml text/css text/js application/x-javascript; } /etc/php-fpm.d/www-data.conf my php-fpm pool config ## Nginx php-fpm Upstream upstream wwwdomaincom { server unix:/var/run/php-fcgi-www-data.sock; } ## Global Config client_max_body_size 10M; server_names_hash_bucket_size 64; ## Web Server Config server { ## Server Info listen 80; server_name domain.com *.domain.com; root /home/www-data/public_html; index index.html index.php; ## Error log error_log /home/www-data/logs/nginx-errors.log; ## DocumentRoot setup location / { try_files $uri $uri/ @handler; expires 30d; } ## These locations would be hidden by .htaccess normally #location /app/ { deny all; } ## Disable .htaccess and other hidden files location /. { return 404; } ## Magento uses a common front handler location @handler { rewrite / /index.php; } ## Forward paths like /js/index.php/x.js to relevant handler location ~ .php/ { rewrite ^(.*.php)/ $1 last; } ## Execute PHP scripts location ~ \.php$ { try_files $uri =404; expires off; fastcgi_read_timeout 900; fastcgi_pass wwwdomaincom; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; include fastcgi_params; } ## GZip Compression gzip on; gzip_comp_level 8; gzip_min_length 1000; gzip_proxied any; gzip_types text/plain application/xml text/css text/js application/x-javascript; } I've got a file in /home/www-data/public_html/index.php with the code <?php phpinfo(); ?> (file uploaded as user www-data).

    Read the article

  • Can IBM IHS server support more than one Websphere Application Server plug-in location?

    - by Spike Williams
    We want http://webserver.com/foo to point to an instance of WAS 6.0, and http://webserver.com/foo2 to point to an instance of WAS 7.0, running on the same server, but with different port numbers. This is a temporary thing, as we need to have both servers running as we transition our applications from running on 6.0 to 7.0. The webserver is IBMIHS (an Apache variant), and it needs to use the WebSphere plugin to connect to the WAS servers. Will this work? Any drawbacks?

    Read the article

  • What are the essential considerations for setting up systems in a location with unreliable power?

    - by dunxd
    I deal with a lot of remote offices located in parts of the world where the local grid power supply is unreliable. Power can go off anytime with no warning, with outages ranging from minutes to days Power fluctuation is wild, with spikes and brown outs Currently the offices will have some or all of the following: A generator, with an inverter, or some sort of manual switch A big UPS or battery array connecting a number of devices Several smaller APC UPS with computers attached Low cost Voltage Regulators sometimes connected between mains and UPS or device. I know that each of these things needs to be appropriately rated for the equipment to which it is connected (although I am not sure how to calculate the correct rating). The offices will generally have the following equipment (in varying quantities): some sort of internet connection device (VSAT router, ADSL modem, WiMax router) Cisco ASA 5505 firewall a bunch of PCs printers one server I don't seek to replace the advice of an electrician, but in some of these locations they only answer the questions you ask them, so I need to make sure I have enough understanding of the essentials to protect equipment from damage, and possibly get through some power cuts.

    Read the article

  • Unable to location existing XP system partition during Windows 7 upgrade install.

    - by glenneroo
    I have Windows XP 32-bit installed on this computer. I just purchased a Windows 7 64-bit as an ISO download upgrade version which I promptly burned to DVD and attempted to perform an upgrade installation. Here is the error message I am getting: Firstly, where are these "Setup log files" located? Second, does this mean I need to find compatible (64-bit?) drivers for the Mainboard and put them on floppy?

    Read the article

  • How to allow Hudson build URL through Nginx auth_basic?

    - by rodreegez
    Hi, I have Hudson running and made available to the world via nginx. I have protected Hudson with nginx's auth_basic and that works great. The trouble is, I want to allow unauthenticated requests to the build URL, i.e. /job/<job_name>/build. Currently I have this in my nginx conf: upstream hudson { server 127.0.0.1:8888; } server { server_name ci.myurl.com; root /var/lib/hudson; location / { proxy_pass http://hudson/; auth_basic "Super secret stuff"; auth_basic_user_file /var/opt/hudson/htpasswd; } location ~ \/build { auth_basic off; } } I can't get that second location to allow unauthenticated requests. I have tried various combinations of location ~ /job/(.*)/biuld { } location ^~ \/build { } location ~ \/job\/(.*)\/build { } etc... Maddening! Can anyone point me in the right direction? Thanks, Ad.

    Read the article

  • How can I trick ssh to connect using different configurations based on current location?

    - by Sorin Sbarnea
    Here is the following use case: wanting to ssh server1 in 3 scenarios: server1 is on current network, go for it server1 is not on current network and you need to use a gateway (gw1) to access it, not a big problem as you can use ~/.ssh/config to define tunnelling for this you are on a network that does not allow you to access the first gw1, so you'll use gw2 for that. Desired outcome: be able to use the same command and be able to connect to the server.

    Read the article

  • Mac app to apply certain settings based on selected location (profile)?

    - by Jonathan
    When my MacBook is connected to my Thunderbolt Display, I want WiFi to be turned off, Bluetooth to be turned on and the screen brightness to be at max. On the road I want WiFi to be turned on, Bluetooth to be turned off and the screen brightness to be somewhere in the middle. It would be easy if there was an application that would let me create several profiles (like 'Home' and 'On the road'), which I could easily select (from Dashboard or the menu bar). The profile settings would then be applied instantly. Does an application like this exist?

    Read the article

  • Where are iSCSI and volume information location on ESX 4.0?

    - by sec_goat
    Let me start by saying I am somewhat of a Vmware novice, I know just enought to manage and create servers at a basic level from the vSphere client. I have a VMWare server, ESX 4.0 connected over iSCSI to a SAN. The SAN is being used as storage for both RDMs and VMFS volumes. The SAN has died and I ordered a new one. Where can I see the settings related to the iSCSI and volume configuration so that I can try and replicate them on the new SAN when it arrives?

    Read the article

  • Remote location's status "Disconnected", how to keep it connected (OK)? [net-use-command]

    - by AZ
    I have an script that keeps running, under some scenarios, it needs to contact a server (\\us-sign). From time to time, if this server remains uncontacted for a while, the next time my script needs it, it will ask for my credentials. What I found is that, after such thing happening and using net use, such server will be displayed as disconnected. if I type "net use \\us-sign", it won't ask me neither user nor password, what makes me believe, my credentials for such server are still "valid", nonetheless, its status will remain "disconnected". This script is supposed to help us automate some procedures, but the need to keep a watch on it shall it request for credentials, it kind of defeats the purpose. How can I keep its status "OK" no matter how long it is not being contacted?

    Read the article

  • Node.js MMO - process and/or map division

    - by Gipsy King
    I am in the phase of designing a mmo browser based game (certainly not massive, but all connected players are in the same universe), and I am struggling with finding a good solution to the problem of distributing players across processes. I'm using node.js with socket.io. I have read this helpful article, but I would like some advice since I am also concerned with different processes. Solution 1: Tie a process to a map location (like a map-cell), connect players to the process corresponding to their location. When a player performs an action, transmit it to all other players in this process. When a player moves away, he will eventually have to connect to another process (automatically). Pros: Easier to implement Cons: Must divide map into zones Player reconnection when moving into a different zone is probably annoying If one zone/process is always busy (has players in it), it doesn't really load-balance, unless I split the zone which may not be always viable There shouldn't be any visible borders Solution 1b: Same as 1, but connect processes of bordering cells, so that players on the other side of the border are visible and such. Maybe even let them interact. Solution 2: Spawn processes on demand, unrelated to a location. Have one special process to keep track of all connected player handles, their location, and the process they're connected to. Then when a player performs an action, the process finds all other nearby players (from the special player-process-location tracking node), and instructs their matching processes to relay the action. Pros: Easy load balancing: spawn more processes Avoids player reconnecting / borders between zones Cons: Harder to implement and test Additional steps of finding players, and relaying event/action to another process If the player-location-process tracking process fails, all other fail too I would like to hear if I'm missing something, or completely off track.

    Read the article

  • How can I change the location of my ip address to Orlando, FL from other city where I live and using forum/chat-room? [on hold]

    - by MSEUCF
    I live in West Palm Beach, Florida. However, I am attending to school at University of Center Florida for materials science and engineering. Right now, I am on vacation and live in WPB, FL. There is one certainly problem when I login at private forum I'm getting error for not same the ip-address so I had to make new account with false information in city and still unable to success. Of course, it won't do that due to policy from forum required the ip-address has to be same in Orlando, FL. local only. How can I change the location of my ip address to Orlando? Also, in chat-room from forum it would show my ip-address so I'd be in trouble if they find out that I am not live in Orlando. Please help with me. Tell me how to change ip adress step and step. Thank you. *I use AT&T and Belkin Router Wifi. Forgiven me for my English is not very well. ESL. I am a foreign student.

    Read the article

  • What data to send when tracking clicks with Google Analytics events (and how)?

    - by user359650
    When tracking clicks on links, there are 3 items I'm interested in: link location in the page by grabbing the id of the closest parent: to see influence of location on click-through link text: to see influence of text on click-through link href attribute value: to see where people go when leaving my website The problem when using Google Analytics to track those clicks is that events only have 3 available text fields, one of which being the category, which if you use to store one of the above items will create a mess in your Event reporting because you will have as many categories as item values. Therefore if you assign a predefined value to the category (e.g. clicks), then you're left with only 2 event fields (action, label) to store 3 items (location, text, href). That in itself isn't the end of the world because you can concatenate 2 items into 1 event field, then use the reporting or the API to filter things out. Accordingly what I plan on doing is this: category: clicks action: {location_on_page} ¦ {text} label: {href} where {__} are variable values related to the clicked links With this I can easily create some reports directly via the GUI: downloads: include only events where label ends with .pdf click outs to particular domains: include only events where label contains domain And for more complex tasks I need to export the data (or use the API): influence of location on clicks: for each location in the design, count number of events that have that location in the action, then corroborate with pageviews of the corresponding pages. Whilst this looks good I'm wondering if there is a better approach, hence the following questions: Q1: Can you foresee any particular issues with this particular setup (e.g. things I won't be able to report on)? Q2: Can you think of other data that would be interesting to include in the event?

    Read the article

  • Wheel rotation, to change velocity of vehicle

    - by Lewis
    I update the velocity of my vehicle like so: [v setVelocity: ((2 * 3.14 * 100 * (wheel.getRotationValue / 360) / 30)) * gameSpeed]; // update on 60 fps this gets velocity on all frames divide by 60 for 1 frame. This is done in my update method in my world class. Now wheel.getRotationValue returns the rotation value which is worked out like this: - (void)ccTouchesMoved:(NSSet *)touches withEvent:(UIEvent *)event { UITouch *touch = [touches anyObject]; CGPoint location = [touch locationInView:[touch view]]; location = [[CCDirector sharedDirector] convertToGL:location]; if (CGRectContainsPoint(wheel.boundingBox, location)) { CGPoint firstLocation = [touch previousLocationInView:[touch view]]; CGPoint location = [touch locationInView:[touch view]]; CGPoint touchingPoint = [[CCDirector sharedDirector] convertToGL:location]; CGPoint firstTouchingPoint = [[CCDirector sharedDirector] convertToGL:firstLocation]; CGPoint firstVector = ccpSub(firstTouchingPoint, wheel.position); CGFloat firstRotateAngle = -ccpToAngle(firstVector); CGFloat previousTouch = CC_RADIANS_TO_DEGREES(firstRotateAngle); CGPoint vector = ccpSub(touchingPoint, wheel.position); CGFloat rotateAngle = -ccpToAngle(vector); CGFloat currentTouch = CC_RADIANS_TO_DEGREES(rotateAngle); float limit = 0.5; rotationValue += (currentTouch - previousTouch) * limit; } touching = YES; } Say I steer the vehicle to the far right of the screen, and want to move it to the far left, It wont start moving to the left of the screen until the rotationValue is past 0 degrees again (the wheel is in its center posistion) and is dragged past this value. Is there anyway to change the code I have above, so that movement on the wheel is recognised instantly and updates the velocity of v instantly too?

    Read the article

  • Rotating wheel with touch adding velocity

    - by Lewis
    I have a wheel control in a game which is setup like so: - (void)ccTouchesMoved:(NSSet *)touches withEvent:(UIEvent *)event { UITouch *touch = [touches anyObject]; CGPoint location = [touch locationInView:[touch view]]; location = [[CCDirector sharedDirector] convertToGL:location]; if (CGRectContainsPoint(wheel.boundingBox, location)) { CGPoint firstLocation = [touch previousLocationInView:[touch view]]; CGPoint location = [touch locationInView:[touch view]]; CGPoint touchingPoint = [[CCDirector sharedDirector] convertToGL:location]; CGPoint firstTouchingPoint = [[CCDirector sharedDirector] convertToGL:firstLocation]; CGPoint firstVector = ccpSub(firstTouchingPoint, wheel.position); CGFloat firstRotateAngle = -ccpToAngle(firstVector); CGFloat previousTouch = CC_RADIANS_TO_DEGREES(firstRotateAngle); CGPoint vector = ccpSub(touchingPoint, wheel.position); CGFloat rotateAngle = -ccpToAngle(vector); CGFloat currentTouch = CC_RADIANS_TO_DEGREES(rotateAngle); wheelRotation += (currentTouch - previousTouch) * 0.6; //limit speed 0.6 } } I update the rotation of a the wheel in the update method by doing: wheel.rotation = wheelRotation; Now once the user lets go of the wheel I want it to rotate back to where it was before but not without taking into account the velocity of the swipe the user has done. This is the bit I really can't get my head around. So if the swipe generates a lot of velocity then the wheel will carry on moving slightly in that direction until the overall force which pulls the wheel back to the starting position kicks in. Any ideas/code snippets?

    Read the article

  • Move SQL Server transaction log to another disk

    - by Jim Lahman
    When restoring a database backup, by default, SQL Server places the database files in the master database file directory.  In this example, that location is in L:\MSSQL10.CHTL\MSSQL\DATA as shown by the issuance of sp_helpfile   Hence, the restored files for the database CHTL_L2_DB are in the same directory     Per SQL Server best practices, the log file should be on its own disk drive so that the database and log file can operate in a sequential manner and perform optimally. The steps to move the log file is as follows: Record the location of the database files and the transaction log files Note the future destination of the transaction log file Get exclusive access to the database Detach from the database Move the log file to the new location Attach to the database Verify new location of transaction log Record the location of the database file To view the current location of the database files, use the system stored procedure, sp_helpfile 1: use chtl_l2_db 2: go 3:   4: sp_helpfile 5: go   Note the future destination of the transaction log file The future destination of the transaction log file will be located in K:\MSSQLLog   Get exclusive access to the database To get exclusive access to the database, alter the database access to single_user.  If users are still connected to the database, remove them by using with rollback immediate option.  Note:  If you had a pane connected to the database when the it is placed into single_user mode, then you will be presented with a reconnection dialog box. 1: alter database chtl_l2_db 2: set single_user with rollback immediate 3: go Detach from the database   Now detach from the database so that we can use windows explorer to move the transaction log file 1: use master 2: go 3:   4: sp_detach_db 'chtl_l2_db' 5: go   After copying the transaction log file re-attach to the database 1: use master 2: go 3:   4: sp_attach_db 'chtl_l2_db', 5: 'L:\MSSQL10.CHTL\MSSQL\DATA\CHTL_L2_DB.MDF', 6: 'K:\MSSQLLog\CHTL_L2_DB_4.LDF', 7: 'L:\MSSQL10.CHTL\MSSQL\DATA\CHTL_L2_DB_1.NDF', 8: 'L:\MSSQL10.CHTL\MSSQL\DATA\CHTL_L2_DB_2.NDF', 9: 'L:\MSSQL10.CHTL\MSSQL\DATA\CHTL_L2_DB_3.NDF' 10: GO

    Read the article

  • Rotating wheel with touch (adding momentum and slowing down the initial rate it can be moved

    - by Lewis
    I have a wheel control in a game which is setup like so: - (void)ccTouchesMoved:(NSSet *)touches withEvent:(UIEvent *)event { UITouch *touch = [touches anyObject]; CGPoint location = [touch locationInView:[touch view]]; location = [[CCDirector sharedDirector] convertToGL:location]; if (CGRectContainsPoint(wheel.boundingBox, location)) { CGPoint firstLocation = [touch previousLocationInView:[touch view]]; CGPoint location = [touch locationInView:[touch view]]; CGPoint touchingPoint = [[CCDirector sharedDirector] convertToGL:location]; CGPoint firstTouchingPoint = [[CCDirector sharedDirector] convertToGL:firstLocation]; CGPoint firstVector = ccpSub(firstTouchingPoint, wheel.position); CGFloat firstRotateAngle = -ccpToAngle(firstVector); CGFloat previousTouch = CC_RADIANS_TO_DEGREES(firstRotateAngle); CGPoint vector = ccpSub(touchingPoint, wheel.position); CGFloat rotateAngle = -ccpToAngle(vector); CGFloat currentTouch = CC_RADIANS_TO_DEGREES(rotateAngle); wheelRotation += (currentTouch - previousTouch) * 0.6; //limit speed 0.6 } } Now once the user lets go of the wheel I want it to rotate back to where it was before but not without taking into account the momentum of the swipe the user has done. This is the bit I really can't get my head around. So if the swipe generates a lot of momentum then the wheel will carry on moving slightly in that direction until the overall force which pulls the wheel back to the starting position kicks in. Any ideas/code snippets?

    Read the article

< Previous Page | 47 48 49 50 51 52 53 54 55 56 57 58  | Next Page >