Search Results

Search found 4721 results on 189 pages for 'traffic'.

Page 51/189 | < Previous Page | 47 48 49 50 51 52 53 54 55 56 57 58  | Next Page >

  • Dual NIC internet access

    - by JavaRocky
    Q1. If a computer had two NICs, lets say windows, on which interface would HTTP traffic (or any for that matter) go out on. Not sure how the routes table would look like. Q2. If one of the NICs link becomes unresponsive, would traffic be automatically routed to the other NIC? Thanks.

    Read the article

  • Nginx and PHP-FPM running out of connections

    - by E3pO
    I keep running into errors like these, [02-Jun-2012 01:52:04] WARNING: [pool www] seems busy (you may need to increase pm.start_servers, or pm.min/max_spare_servers), spawning 8 children, there are 19 idle, and 49 total children [02-Jun-2012 01:52:05] WARNING: [pool www] seems busy (you may need to increase pm.start_servers, or pm.min/max_spare_servers), spawning 16 children, there are 19 idle, and 50 total children [02-Jun-2012 01:52:06] WARNING: [pool www] seems busy (you may need to increase pm.start_servers, or pm.min/max_spare_servers), spawning 32 children, there are 19 idle, and 51 total children [02-Jun-2012 03:10:51] WARNING: [pool www] seems busy (you may need to increase pm.start_servers, or pm.min/max_spare_servers), spawning 8 children, there are 18 idle, and 91 total children I changed my settings for php-fpm to these, pm.max_children = 150 (It was at 100, i got a max_children reached and upped to 150) pm.start_servers = 75 pm.min_spare_servers = 20 pm.max_spare_servers = 150 Resulting in [02-Jun-2012 01:39:19] WARNING: [pool www] server reached pm.max_children setting (150), consider raising it I've just launched a new website that is getting a conciderable amount of traffic on it. This traffic is legitimate and users are getting 504 gateway timeouts when the limit is reached. I have limited connections to my server with IPTABLES and I'm running fail2ban and keeping track of nginx access logs. The traffic is all legitimate, i'm just running out of room for users. I'm currently running on a dual core box with ubuntu 64bit. free total used free shared buffers cached Mem: 6114284 5726984 387300 0 141612 4985384 -/+ buffers/cache: 599988 5514296 Swap: 524284 5804 518480 My php.ini max_input_time = 60 My nginx config is worker_processes 4; pid /var/run/nginx.pid; events { worker_connections 19000; # multi_accept on; } worker_rlimit_nofile 20000; #each connection needs a filehandle (or 2 if you are proxying) client_max_body_size 30M; client_body_timeout 10; client_header_timeout 10; keepalive_timeout 5 5; send_timeout 10; location ~ \.php$ { try_files $uri /er/error.php; fastcgi_split_path_info ^(.+\.php)(/.+)$; fastcgi_connect_timeout 60; fastcgi_send_timeout 180; fastcgi_read_timeout 180; fastcgi_buffer_size 128k; fastcgi_buffers 256 16k; fastcgi_busy_buffers_size 256k; fastcgi_temp_file_write_size 256k; fastcgi_max_temp_file_size 0; fastcgi_intercept_errors on; fastcgi_pass unix:/tmp/php5-fpm.sock; fastcgi_index index.php; include fastcgi_params; } What can I do to stop running out of connections? Why does this keep occurring? I'm monitoring my traffic on Google Analytics realtime and when the user count gets above about 120 my php-fpm.log is full of these warnings..

    Read the article

  • Nginx Reverse proxy + SYN Flood

    - by Bradley
    We're running a nginx reverse proxy cluster, forwarding traffic to our main website, this enables us to filter out unwanted traffic/users etc, and send them off else where, now we have a few issues with SYN floods where the requests a second is overflowing the proxy + the main server causing them to become unavailable. Is there any ip tables magic that can A) Rate limit SYN packets / connections to HTTP B) Block it all together if packets a second is malicious or any advice how to use limit_rate_zone in nginx, I've googled and tried to apply a few new results and none of them work and the websites are still unavailable.

    Read the article

  • Windows Server 2003 IPSec Tunnel Connected, But Not Working (Possibly NAT/RRAS Related)

    - by Kevinoid
    Configuration I have setup a "raw" IPSec tunnel between a Windows Server 2003 (SBS) machine and a Netgear FVG318 according to the instructions in Microsoft KB816514. The configuration is as follows (using the same conventions as the article): NetA | SBS2003 | FVG318 | NetB 10.0.0.0/24 | 216.x.x.x | 69.y.y.y | 10.0.254.0/24 Both the Main Mode and Quick Mode Security Associations are successfully completed and appear in the IP Security Monitor. I am also able to ping the SBS2003 server on its private address from any computer on NetB. The Problem Any traffic sent from a computer on NetA to NetB, or from SBS2003 to NetB (excluding ICMP Ping responses), is sent out on the public network interface outside the IPSec tunnel (no encryption or header authentication, as if the tunnel were not there). Pings sent from a computer on NetB to a computer on NetA successfully reach computers on NetA, but the responses are silently discarded by SBS2003 (they do not go out in the clear and do not generate any encrypted traffic). Possible Solutions Incorrect Configuration I could have mistyped something, somewhere, or KB816514 could be incorrect in some way. I have tried very hard to eliminate the first option. Have re-created the configuration several times, tried tweaking and adjusting all the settings I could without success (most prevent the SA from being established). NAT/RRAS I have seen multiple posts elsewhere suggesting that this could be due to interaction between NAT and the IPSec filters. Possibly the NetA private addresses get rewritten to 216.x.x.x before being compared with the Quick Mode IPSec filters and don't get tunneled because of the mismatch. In fact, The Cable Guy article from June 2005 "TCP/IP Packet Processing Paths" suggests that this is the case, (see step 2 and 4 of the Transit Traffic path). If this is the case, is there a way to exclude NetA-NetB traffic from NAT? Any thoughts, ideas, suggestions, and/or comments are appreciated. Update (2011-06-26) After failing to solve the problem, I resorted to paid Microsoft support. They were unable to solve the problem. Since then I have implemented a solution based on Linux that is working quite well. I will attempt to evaluate any proposed answers as best I can, but current configurations and time constraints will make this slow...

    Read the article

  • Iptables -gw parameter

    - by schoen
    I want to copy tcp traffic. i want to use these commands " iptables -A PREROUTING -t mangle -p tcp --dport 7 -j ROUTE --gw 1.2.3.4 --tee iptables -A POSTROUTING -t mangle -p tcp --sport 7 -j ROUTE --gw 1.2.3.4 --tee" like stated here http://stackoverflow.com/questions/7247668/duplicate-tcp-traffic-with-a-proxy but iptables keeps telling me "iptables v1.4.8: unknown option '--gw'" What can I do to fix this? With Kind Regards

    Read the article

  • Does VPN connection on virtual machine bypass host VPN?

    - by Daniel Valland Torgrimsen
    I wanted to see if i could channel my traffic trough two vpns, so as an experiment i set up a windows xp virtual machine in virtualbox (using NAT shared network setting), connected the host pc(windows 7) to a vpn, and then the virtual machine to another vpn. this seams to work fine. However, my question is, is the traffic sent trough both vpn servers, or is the virtual machines vpn bypassing the host machines vpn connection? thanks.

    Read the article

  • Dynamips and Tap Devices, To and From the same machine

    - by Kyle Brandt
    I am setting up a dynamips/dynagen lab and am wondering if there is any way to get traffic to route out one tap devices, go into the lab, and come back to a tap device on the same machine. I have tried host specific routes as well as removing the route created when I give the tun device an ip via ifconfig. With both of these, traffic always preferes the attached devices and won't go through my lab. Any way to make this work without a separate machine or vm?

    Read the article

  • Capturing multicast data with Wireshark with IGMP Snooping Enabled at the switch

    - by Chuu
    I am trying to capture multicast traffic via Wireshark (actually TShark), however the switch has IGMP snooping enabled and will only send Multicast traffic on the ports that have an active IGMP subscription. I am currently getting around this by having a separate application hold the groups open I wish to record, but I am trying to set up a system to start/stop recording data dynamically and this extra complexity is painful. Is there a way to force Wireshark to send out IGMP Subscriptions for multicast groups it is recording?

    Read the article

  • Squidguard (or equivalent) for IPv6

    - by Matthew Iselin
    We have recently implemented (native) IPv6 in our network. Everything is working very well so far, but our IPv4 network passes all HTTP traffic through Squid (2.7.STABLE6 on Ubuntu Server) + SquidGuard for filtering purposes. This is all managed via a redirect rule on the firewall (via Shorewall). I'm wondering now if it's possible to do the same thing with IPv6 at all. If it's any help we're using Shorewall6 for IPv6 traffic.

    Read the article

  • What are some of the best wireless routers for a price-conscious home power-user?

    - by Alain
    I'm extremely dissatisfied with the 'popular' choice for routers in homes and small offices. They are expensive (upwards of 60$), lack a great deal of useful configuration options, and seem to need to be restarted quite often. (Linksys comes to mind). I've been on the market for a good router lately, and slowly collecting a set of requirements I feel good routers should meet. Maximum number of TCP/IP connections. - This isn't something I see any routers advertise, but in terms of supporting torrent applications, I've been screwed by routers that support less than 20 here. From what I understand a fairly standard number is 200, but there are not so expensive routers that support thousands. Router configuration menu - Most have standard menu's that let you set up basic things like your wireless network encryption settings, uPnP, and maybe even DMZ (demilitarized zones). An absolute requirement for me, however, are routers with good enough firmware to support: Explicit Port forwarding Assigning static local ips to specific mac addresses, or at least Port forwarding by MAC address Port, IP and MAC filtering Dynamic DNS service for home users who want to set up a server but have a dynamic IP Traffic shaping (ideally) - giving priority to packets from certain machines or over certain ports. Strong wireless signal - If getting a reliable signal requires me to be so close to the router that I can connect an Ethernet cable, it's not good enough. As many Ethernet ports as possible. - Because I want to be able to switch from console gaming to PC gaming without visiting my router. So far, the best thing I've stumbled upon (in the bargain bin at staples) was a 20$ retail plus router. It was meant to be the cheapest alternative until I could find something better to purchase online, but I was actually blown away by the firmware capabilities. It supports defining reserved bandwidth for certain network traffic, dynamic DNS, reserving local IPs for specific MAC addresses, etc. At 2 am when my roommate is killing our Internet with their torrents, I can limit their bandwidth without outright blacklisting them. I have, however, met serious limitations when it comes to network traffic between local machines. It claims a 300Mbps connection, but I have trouble streaming videos from my PC to my console or other laptops wirelessly. It has a meltdown and needs to be reset once in a while (no more than a couple times a month), and it's got a 200 connection limit. There 4 Ethernet ports in the back but I'm pretty sure the first doesn't work. So some great answers to this question would be: Any metrics you use to compare routers, and requirements you have for new candidates. The best routers you've found for supporting home servers, file management systems, high volume torrent traffic, good price/feature ratio, etc. Good configuration advice (aside from 'use Ethernet whenever possible') Thanks for your feedback and experiences!

    Read the article

  • Possible to direct naked domain to external IP

    - by Luke
    So I found this post: configure Bind to have a custom domain on tumblr and I was trying to ask a related question: Would it be possible to set up an A record pointing traffic to domain.com to Tumblr and feed.domain.com to the IP address of my choice? In other words, by setting up a naked domain A record to Tumblr's IP, will I inherently lose traffic to feed.domain.com? Can I write another A record for the specific subdomains I want to point to my server? I hope this makes sense.

    Read the article

  • Redirect local service to custom proxy

    - by Pedro Laguna
    Hello, I'm trying to create a custom proxy program but I have a problem. My program connects to a fixed port from a random port and I need to tunnel all this traffic by my local proxy. I think the solution is using iptables, but all the topics I found are related to redirect incoming connections, not outbounds. How can I redirect all the traffic from a local port to another local port and later to the internet? Thanks,

    Read the article

  • How can I simulate blocking RTMP over port 80 on Windows?

    - by Christian Nunciato
    It seems like this should be so simple, but since this isn't my area of expertise, I'm having a hell of a time figuring out how to do it. Basically, I have a Flash app and I'm connecting to a Flash Media Server to stream some content. The URL I'm using to do this, for example, looks like this: rtmp://someserver.com/some/path/mp3:somefile Everything works -- but that's sort of the problem. When I'm trying to do is simulate my users attempting to play back my media under more restrictive conditions than the ones I have here (i.e., none) -- namely being stuck behind firewalls or proxy servers that block access to RTMP streams. Flash, according to Adobe, is equipped to handle proxy servers and firewalls automatically, like so (from the docs): When you do not specify a port number in an RTMP address, Flash will attempt to connect to port 1935. If it fails it will then try to connect to port 443; if that fails, it will try port 80. [And if that fails, it will attempt to connect via RTMPT (i.e., HTTP tunneling) on port 80.] So no coding is required to access ports 1935, 443, or port 80 if you do not specify a port in the RTMP address. The problem I'm having is setting up a reliable environment in which to test that this behavior actually happens. I'm on a Windows machine, for example, so with Windows Firewall, I can block certain ports and protocols (1935, 443), but I don't want to block port 80, because the final fallback protocol (RTMPT) is supposed to run on port 80, and Windows Firewall only gives me enough granularity (as far as I know, anyway) to block "all outbound TCP traffic to remote port 80" -- that is, I can't, apparently, block "all outbound RTMP traffic to port 80" while leaving RTMPT traffic to port 80 unaffected. My understanding thus far is that I'll probably need to set up a proxy server to do this. Is this correct? Or is there a simpler way (on Win 7, at least) to filter out RTMP to 1935, RTMP to 443, RTMP to 80, but still allow RTMPT to 80 (where all four hostnames are identical)? And if I do have to set up a proxy server, what's the simplest way to go on Windows? I've set up WinProxy, which seems a bit janky but apparently works -- but then what I can't figure out is how to tell Windows to force all TCP traffic (including RTMP, RTMPT and HTTO) through this proxy server so I can turn around and reject the requests for RTMP. Any help would be hugely appreciated. This isn't my realm of expertise and I've alreasdy spent more time on it than I probably should. :)

    Read the article

  • Openvpn mat through access server depending on client

    - by Lucas Kauffman
    I have several services which should be accessible through a VPN. Clients who connect through the VPN server should be NATed so that all their traffic passes through the access server. However server residing on the network should not pass their traffic through the access server their VPN facing services should be accessible, but their internet connections should not pas through the access server. So how can I enable NAT on a per client basis using OpenVPN?

    Read the article

  • apache or nginx or lighttpd ?

    - by vk123
    I'm going to be live blogging from a event and expect huge spike in traffic. im currently using apache with modphp and it died last year under traffic Don't want it to happen again. I'm thinking of setting up a separate VPS for this blog running on worpdress what should i install ? apache . lighttpd or nginx ? which will perform the best under heavy load ? content will be very dynamic - AJAX updates

    Read the article

  • How do you set up SSL and Nginx Proxying?

    - by Jason Christa
    I have Nginx listening to traffic on port 80 and proxying certain request to Apache over port 8080. I am going to set up Nginx to listen to port 443 for https traffic, but my question is how should the proxying be done now? Does the proxy to Apache need to be https or has Nginx already decoded it so I can keep sending it to Apache over port 8080. BTW, Apache is running with the least amount of modules installed possible and has currently has no SSL related modules, would I need to install any?

    Read the article

  • possible UDP attack on BIND?

    - by Waleed Hamra
    hello everyone, i was surprised last month when my EC2 instance (ubuntu precise server), that is supposed to be under the free tier still, accumulated lots of traffic... today, while checking my current billing statement, i noticed i already have tons of traffic, while still in the middle of the month, and i'm fearing what my bill by the end of the month is going to be... i installed bandwidthd, and after few minutes, i noticed lots of UDP traffic to "108.162.233.15". this is apparently a cloudflare IP, and i don't have anything using cloudflare (as far as i know). so i ran "iftop" to see what ports are being used, and i saw the UDP traffic coming from port 80 to my port 53... why would a webserver query dns? so i stopped bind on my server, and ran it in foreground debugging mode, and saw the following query, being repeated continuously: 17-Nov-2012 12:30:58.216 client 108.162.233.15#80: UDP request 17-Nov-2012 12:30:58.216 client 108.162.233.15#80: request is not signed 17-Nov-2012 12:30:58.216 client 108.162.233.15#80: recursion available 17-Nov-2012 12:30:58.216 client 108.162.233.15#80: query 17-Nov-2012 12:30:58.216 client 108.162.233.15#80: query (cache) 'isc.org/ANY/IN' approved 17-Nov-2012 12:30:58.216 client 108.162.233.15#80: send 17-Nov-2012 12:30:58.216 client 108.162.233.15#80: sendto 17-Nov-2012 12:30:58.216 client 108.162.233.15#80: senddone 17-Nov-2012 12:30:58.217 client 108.162.233.15#80: next 17-Nov-2012 12:30:58.217 client 108.162.233.15#80: endrequest 17-Nov-2012 12:30:58.217 client @0x7fbee05126e0: udprecv 17-Nov-2012 12:30:58.343 client 108.162.233.15#80: UDP request 17-Nov-2012 12:30:58.343 client 108.162.233.15#80: request is not signed 17-Nov-2012 12:30:58.343 client 108.162.233.15#80: recursion available 17-Nov-2012 12:30:58.343 client 108.162.233.15#80: query 17-Nov-2012 12:30:58.343 client 108.162.233.15#80: query (cache) 'isc.org/ANY/IN' approved 17-Nov-2012 12:30:58.343 client 108.162.233.15#80: send 17-Nov-2012 12:30:58.344 client 108.162.233.15#80: sendto 17-Nov-2012 12:30:58.344 client 108.162.233.15#80: senddone 17-Nov-2012 12:30:58.344 client 108.162.233.15#80: next 17-Nov-2012 12:30:58.344 client 108.162.233.15#80: endrequest my question is... is this normal? should i be worried? or is this completely irrelevant to my data charges, and i should wait to see more data from bandwidthd? thank you in advance.

    Read the article

  • monitor internet bandwidth

    - by enriquev
    Hello, I'm looking for a windows tool that can tell me who is using bandwith. As of now I've setup so that the switch where all pcs are connected, mirrors the router's traffic to my pc, meaning that from my NIC I am able to see all outgoing and incoming internet connections. This works, I have used NIMAS (http://www.vmware.com/appliances/directory/200) and I am able to see internet traffic. Now what I am looking for is something even more simple, where I can see what computers are using what banwidth, live.

    Read the article

  • How secure are third party Ubuntu (APT) repository mirrors

    - by bakytn
    Hello! We have locally an Ubuntu mirrors to save a lot of traffic (our external traffic is not free) So whenever I apt-get install "program" it gets from that repository. the question is...basically they can substitute any package with their own? So it's 100% on my own risk and I can be hacked easily on any apt-get upgrade or a-g install or a-g dist-upgrade? for example the very basic ones like "telnet" or any other.

    Read the article

  • Fibre channel long distance woes

    - by Marki
    I need a fresh pair of eyes. We're using a 15km fibre optic line across which fibrechannel and 10GbE is multiplexed (passive optical CWDM). For FC we have long distance lasers suitable up to 40km (Skylane SFCxx0404F0D). The multiplexer is limited by the SFPs which can do max. 4Gb fibrechannel. The FC switch is a Brocade 5000 series. The respective wavelengths are 1550,1570,1590 and 1610nm for FC and 1530nm for 10GbE. The problem is the 4GbFC fabrics are almost never clean. Sometimes they are for a while even with a lot of traffic on them. Then they may suddenly start producing errors (RX CRC, RX encoding, RX disparity, ...) even with only marginal traffic on them. I am attaching some error and traffic graphs. Errors are currently in the order of 50-100 errors per 5 minutes when with 1Gb/s traffic. Optics Here is the power output of one port summarized (collected using sfpshow on different switches) SITE-A units=uW (microwatt) SITE-B ********************************************** FAB1 SW1 TX 1234.3 RX 49.1 SW3 1550nm (ko) RX 95.2 TX 1175.6 FAB2 SW2 TX 1422.0 RX 104.6 SW4 1610nm (ok) RX 54.3 TX 1468.4 What I find curious at this point is the asymmetry in the power levels. While SW2 transmits with 1422uW which SW4 receives with 104uW, SW2 only receives the SW4 signal with similar original power only with 54uW. Vice versa for SW1-3. Anyway the SFPs have RX sensitivity down to -18dBm (ca. 20uW) so in any case it should be fine... But nothing is. Some SFPs have been diagnosed as malfunctioning by the manufacturer (the 1550nm ones shown above with "ko"). The 1610nm ones apparently are ok, they have been tested using a traffic generator. The leased line has also been tested more than once. All is within tolerances. I'm awaiting the replacements but for some reason I don't believe it will make things better as the apparently good ones don't produce ZERO errors either. Earlier there was active equipment involved (some kind of 4GFC retimer) before putting the signal on the line. No idea why. That equipment was eliminated because of the problems so we now only have: the long distance laser in the switch, (new) 10m LC-SC monomode cable to the mux (for each fabric), the leased line, the same thing but reversed on the other side of the link. FC switches Here is a port config from the Brocade portcfgshow (it's like that on both sides, obviously) Area Number: 0 Speed Level: 4G Fill Word(On Active) 0(Idle-Idle) Fill Word(Current) 0(Idle-Idle) AL_PA Offset 13: OFF Trunk Port ON Long Distance LS VC Link Init OFF Desired Distance 32 Km Reserved Buffers 70 Locked L_Port OFF Locked G_Port OFF Disabled E_Port OFF Locked E_Port OFF ISL R_RDY Mode OFF RSCN Suppressed OFF Persistent Disable OFF LOS TOV enable OFF NPIV capability ON QOS E_Port OFF Port Auto Disable: OFF Rate Limit OFF EX Port OFF Mirror Port OFF Credit Recovery ON F_Port Buffers OFF Fault Delay: 0(R_A_TOV) NPIV PP Limit: 126 CSCTL mode: OFF Forcing the links to 2GbFC produces no errors, but we bought 4GbFC and we want 4GbFC. I don't know where to look anymore. Any ideas what to try next or how to proceed? If we can't make 4GbFC work reliably I wonder what the people working with 8 or 16 do... I don't assume that "a few errors here and there" are acceptable. Oh and BTW we are in contact with everyone of the manufacturers (FC switch, MUX, SFPs, ...) Except for the SFPs to be changed (some have been changed before) nobody has a clue. Brocade SAN Health says the fabric is ok. MUX, well, it's passive, it's only a prism, nature at it's best. Any shots in the dark? APPENDIX: Answers to your questions @Chopper3: This is the second generation of Brocades exhibiting the problem. Before we had 5000s, now we have 5100s. In the beginning when we still had the active MUX we rented a longdistance laser once to put it into the switch directly in order to make tests for a day, during that day of course it was clean. But as I said, sometimes it's clean just like that. And sometimes it's not. Alternative switches would mean to rebuild the entire SAN with those only to test. Alternative SFPs, well they're hard to come by just like that. @longneck: The line is rented. It's a dark fibre (9um monomode) so there's noone else on it. Sure there are splices. I can't go and look but I have to trust they have been done correctly. As I said the line has been checked and rechecked (using an optical time-domain reflectometer). Obviously you don't have all this equipment yourself because it's way too expensive. @mdpc: What would be the "wrong" type of cable according to you? Up to the switch everything is monomode, yes. The connectors are the correct ones too. Yeah I know there are the green ones where the fibre is cut off at a certain angle etc. But we have the correct ones for all that I know. Progress Report #1 We have had two fabrics (=2x2 switches) with Brocade 5100s with FabricOS 6.4.1 and two fabrics (another 2x4 switches) on FabricOS 7.0.2. On the longdistance ISLs (one in each fabric) it turned out that with FOS 6.4.1 setting it to long distance issues warnings about the VC Init setting and consequently the fill word. But those are only warnings. FOS 7.0.2 requires you to do modifications to VCI and the fillword for long distance links. Setting FOS 6.4.1 to the LS (long-distance static distance) setting with wrong VCI and fillword setting made the whole fabric inoperational (stuck in an SCN loop, use fabriclog -s to see, you don't see it anywhere else, no port error counters or anything increasing). Currently I'm giving the one fabric with the IMHO more correct settings a beating and it seems to do fine, whereas the other one without much traffic still has errors here and there. In short: We have eliminated the active part of the MUX (the FC retimer). We are putting the long distance SFPs into the end equipment themselves. Just to be sure we bought new monomode cables to connect the end equipment to the remaining passive part of the MUX. We are now trying out several long distance configs. It's almost black magic. Everything that happens is mostly empirical, noone seems to have a clue what are the exact reasons to do something. ("We have tried this, and it didn't work, then we tried that and it worked, so we stuck with that." But noone really seems to know why.) I'll keep you updated. Progress Report #2 We got the new lasers for one of the fabrics on warranty. It's ultra clean even on 4GbFC. They're transmitting with roughly 2mW (3dBm) whereas the others are only at 1.5mW (1.5dBm) although that should really be enough. The other fabric (where the lasers are apparently ok) still produces one or two CRCs infrequently. Using sfpshow the SFP producing the actual RX errors shows Status/Ctrl: 0x82 Alarm flags[0,1] = 0x5, 0x40 Warn Flags[0,1] = 0x5, 0x40 Now I'll have to find out what that means. Not sure if it was there before. Well I'll first clear my head with a week of vacation. 8-)

    Read the article

  • Setting up dual NICs under Server 2008

    - by Randall Sexton
    Hi, I'm trying to determine how to set up dual NICs on my Server 2008 box (not R2). I want all web traffic on one NIC and all Hyper-V traffic on the other. Is this possible? ( I assume that it is ) How is this done? ( A link to a tutorial you know of would be great ) Both NICs are the same (Intel PRO/1000 EB Network Connection with I/O Acceleration). Thanks in advance, Randall

    Read the article

  • Browser caching is generating hugo I/O to server

    - by Rime
    Our users My Documents are stored on a Emc NAS. I have noticed huge traffic coming from users and I see that most of it is coming to cache directories of Internet Explorer and other browsers. One thing i suspect is Adobe Flash caching streams. We have various Windows clients and no restrictions on browsers. Is there any way to remove this traffic from our NAS by a group policy or whatever? Thanks Rime

    Read the article

  • Routing RFC1918 addresses through dd-wrt via a switch

    - by espenfjo
    I am a bit stuck with an experiment of mine. I have a network looking somewhat like this. | Internet | | ---- |Switch| ---- | | Server w/pub IP | DD-WRT router 192.168.1.1 | | RFC1918 clients 192.168.1.0/24 What I want is for the RFC1918 clients to speak directly with each others. On the server with the public IP I have this route: 192.168.1.0/24 dev eth0 scope link and can see that packets are infact reaching the dd-wrt router for 192.168.1.1, even though if I get no answer. Trying to reach one of the RFC1918 clients from the public IP server will get no result, as the dd-wrt router is not announcing that network on to its external interface (arp who-has 192.168.1.107 tell xxx.xxx.xxx.xxx, but no answer). The router being an WLAN dd-wrt router has of course a load of routes, VLANs and interfaces: xxx.xxx.xxx.1 dev vlan2 scope link 192.168.1.0/24 dev br0 proto kernel scope link src 192.168.1.1 192.168.1.0/24 dev eth1 proto kernel scope link src 192.168.1.244 84.215.64.0/18 dev vlan2 proto kernel scope link src xxx.xxx.xxx.xxx 169.254.0.0/16 dev br0 proto kernel scope link src 169.254.255.1 127.0.0.0/8 dev lo scope link 0.0.0.0 via xxx.xxx.xxx.1 dev vlan2 xxx.xxx.xxx.xxx being the public IP, and xxx.xxx.xxx.1 being the default route for the public IP. I am not sure where to continue with this. I would recon that I both need routing on the dd-wrt router, as well as some iptables magic? Why do something this complex? Why not ;) Also, do not mind that "Internet" can get RFC1918 traffic, it wont go outside of the walls. EDIT 1: Following the tip from stew I do indeed get the correct ARP flowing. And adding an iptables rule for allowing traffic from that specific public IPd machine I get traffic between the systems! Oddly enough though, the speed I get from Server w/pub IP - RFC1918 clients are the same as if the traffic were routed out onto the Internet and back. Edit 2: Ok, disconnecting the external Internet connection will still give the same, crappy transfer speed. So it has to be something else. Edit 3: Ok, I guess there are other reasons for this crappy speed. Case closed. :)

    Read the article

  • Wireshark vs Netmon for precise time tagging

    - by Nic
    I'm using Wireshark to time tag and get some statistics on multicast traffic. When there is not much traffic, the stats looks good, but as soon as there is a bunch of packets arriving at the same time, I have stats that are not even possible (e.g. round trip time of 0ms) I'm wondering if Netmon could be more precise in time tagging packet because it is not relying on the Winpcap driver? Does anybody already faced the same situation? Thanks a lot, Nic

    Read the article

< Previous Page | 47 48 49 50 51 52 53 54 55 56 57 58  | Next Page >