Search Results

Search found 5429 results on 218 pages for 'smart pointers'.

Page 52/218 | < Previous Page | 48 49 50 51 52 53 54 55 56 57 58 59  | Next Page >

  • Type-safe generic data structures in plain-old C?

    - by Bradford Larsen
    I have done far more C++ programming than "plain old C" programming. One thing I sorely miss when programming in plain C is type-safe generic data structures, which are provided in C++ via templates. For sake of concreteness, consider a generic singly linked list. In C++, it is a simple matter to define your own template class, and then instantiate it for the types you need. In C, I can think of a few ways of implementing a generic singly linked list: Write the linked list type(s) and supporting procedures once, using void pointers to go around the type system. Write preprocessor macros taking the necessary type names, etc, to generate a type-specific version of the data structure and supporting procedures. Use a more sophisticated, stand-alone tool to generate the code for the types you need. I don't like option 1, as it is subverts the type system, and would likely have worse performance than a specialized type-specific implementation. Using a uniform representation of the data structure for all types, and casting to/from void pointers, so far as I can see, necessitates an indirection that would be avoided by an implementation specialized for the element type. Option 2 doesn't require any extra tools, but it feels somewhat clunky, and could give bad compiler errors when used improperly. Option 3 could give better compiler error messages than option 2, as the specialized data structure code would reside in expanded form that could be opened in an editor and inspected by the programmer (as opposed to code generated by preprocessor macros). However, this option is the most heavyweight, a sort of "poor-man's templates". I have used this approach before, using a simple sed script to specialize a "templated" version of some C code. I would like to program my future "low-level" projects in C rather than C++, but have been frightened by the thought of rewriting common data structures for each specific type. What experience do people have with this issue? Are there good libraries of generic data structures and algorithms in C that do not go with Option 1 (i.e. casting to and from void pointers, which sacrifices type safety and adds a level of indirection)?

    Read the article

  • ARC and __unsafe_unretained

    - by J Shapiro
    I think I have a pretty good understanding of ARC and the proper use cases for selecting an appropriate lifetime qualifiers (__strong, __weak, __unsafe_unretained, and __autoreleasing). However, in my testing, I've found one example that doesn't make sense to me. As I understand it, both __weak and __unsafe_unretained do not add a retain count. Therefore, if there are no other __strong pointers to the object, it is instantly deallocated. The only difference in this process is that __weak pointers are set to nil, and __unsafe_unretained pointers are left alone. If I create a __weak pointer to a simple, custom object (composed of one NSString property), I see the expected (null) value when trying to access a property: Test * __weak myTest = [[Test alloc] init]; myTest.myVal = @"Hi!"; NSLog(@"Value: %@", myTest.myVal); // Prints Value: (null) Similarly, I would expect the __unsafe_unretained lifetime qualifier to cause a crash, due to the resulting dangling pointer. However, it doesn't. In this next test, I see the actual value: Test * __unsafe_unretained myTest = [[Test alloc] init]; myTest.myVal = @"Hi!"; NSLog(@"Value: %@", myTest.myVal); // Prints Value: Hi! Why doesn't the __unsafe_unretained object become deallocated?

    Read the article

  • Recommendation for PHP-FPM pm.max_children, PHP-FPM pm.start_servers and others

    - by jaypabs
    I have the following server: Intel® Xeon® E3-1270 v2 Single Processor - Quad Core Dedicated Server CPU Speed: 4 x 3.5 Ghz w/ 8MB Smart Cache Motherboard: SuperMicro X9SCM-F Total Cores: 4 Cores + 8 Threads RAM: 32 GB DDR3 1333 ECC Hard Drive: 120GB Smart Cache: 8MB I am using ubuntu 12.04 - nginx, php, mysql with ISPConfig 3. Under ISPConfig 3 website settings: I have this default value: PHP-FPM pm.max_children = 10 PHP-FPM pm.start_servers = 2 PHP-FPM pm.min_spare_servers = 1 PHP-FPM pm.max_spare_servers = 5 PHP-FPM pm.max_requests = 0 My question is what is the recommended settings for the above variable? Because I found some using a different settings.

    Read the article

  • Two SATA HDDs connected using a Black Duet HDD Docking Station via eSATA to my Laptop, second drive

    - by leeand00
    Hi I am using a BlacX Duet HDD Docking Station to connect a 1TB WD Caviar Black SATA HDD (WD10000LSRTL) and a HITACHI SATA DESKSTAR (0S00163) to my G51VX (BestBuy) laptop via the eSATA port. When I plug in both HDDs in to the Docking Station, connect the docking station to my laptop and start Windows 7 (64-bit Ultimate), only the HDD in the first drive in the port actually shows up in My Computer and Disk Management. If I swap the drives positions I can get them both to work, but never at the same time. I also checked in the bios settings on the laptop, under Advanced-IDE Configuration-SATA Operation Mode, and it displays: SATA Operation Mode: [Enhanced] AHCI Port0 [Hard Disk] Device: Hard Disk Vendor: ST9320421AS LBA Mode: Supported S.M.A.R.T.: Supported AHCI Port5 [Hard Disk] Device: Hard Disk Vendor: Hitachi HDS721010CLA332 Size: 100.00 GB LBA Mode: Supported S.M.A.R.T.: Supported There should be a third drive, but I'm not certain why it is not being picked up. Additionally, before I played around with the settings in the IDE configuration, it used to display the DVD as well.

    Read the article

  • DNS and DHCP not agreeing on an IP address

    - by Mr. Jefferson
    I'm having a problem where our Windows Server 2003 domain controller assigns my Windows 7 computer one IP address (x.x.x.75) via DHCP, but reports another (x.x.x.84) via DNS. This causes some interesting behavior on the network. If I change my adapter settings to get IP and DNS addresses from DHCP, I can access the internet, but no one on our network can access my computer. If I change my IP manually to what DNS says it is, I lose my internet access, but everyone can get to my computer again. I know that we have some old, invalid reverse DNS pointers hanging around (a reverse lookup on an IP address often gives more than one result, usually not including the one that is correct), so that could be contributing, but my problem is recent, and the invalid reverse pointers have been around a long time. What's going on, and how do I fix it?

    Read the article

  • OCZ Vertex 2 not recognized by Ubuntu installer

    - by Zsub
    As I boot into the Ubuntu 10.10 (or 11.04, doesn't matter) live environment or installer, it just refuses to recognise my Vertex 2. It reports the disk as ATA and not supporting smart, shows no serial number, and doesn't list the size correctly. All fdisk tells me is Unable to read /dev/sda (it's the only storage in the PC). I'm now running a temporary install of Windows 7 off of it, which worked like a charm, so where am I going wrong with Ubuntu... Specs: Asus M4N68T-M LE V2 (BIOS 0702, most recent) OCZ Vertex 2 SSD 60 GB Amd Athlon II X4 640 Patriot PSD34G13332 4GB DDR3 ram (two banks) EDIT I installed a second drive, installed Ubuntu on that and booted, it recognised the SSD just fine. I'm now trying to apt-get upgrade the live-environment. I wonder if there is any way to sort of install Ubuntu from Ubuntu (I boot into the working install on the other drive, install it on the SSD and then boot from the SSD). EDIT2 Ok, so that doesn't work. The install detects the SSD, however, it cannot format it. EDIT3 After a fresh boot I can read out SMART-data and even perform a read-benchmark, but if I try to format it, or do a write-bench, it'll crap out and after that it says SMART is not supported. So basically it seems I can't write to the disk, as it will stop working when I do, I will try to run repeated read-benchmarks to see if that has any effect. EDIT4 I'm running several read benchmarks on the drive right now, they give results that are to be expected from an SSD. If the read-benches don't fail, I can use fdisk on the disk, but it is now stuck trying to re-read the partition table after issueing the 'w' command. EDIT5 Parted Magic did recognize the drive and with hdparm -I even could tell me the drive was in a frozen state. I powercycled it (just pull out the plug from the SSD and plug it back in) and it wasn't frozen anymore. After that I could upgrade the firmware on the drive (still using Parted Magic) and format it to Ext4. After I rebooted into the Ubuntu installer, it wouldn't get recognized and hdparm didn't want to talk to it saying HDIO_DRIVE_CMD(identify) failed: Invalid exchange. EDIT6 For some reason if I enable one of the RAID controllers (the one the SSD is connected to, obviously) Ubuntu will let me format it, mount it and write to it. The installer also recognizes it. However if the raid controller is enabled but no array is defined the motherboard can't boot from it :(

    Read the article

  • Adaptec 5805 after reboot don't starting

    - by Rakedko ShotGuns
    After rebooting the system, the controller is not included. It only works if the computer is shut down and turn off. Late i update firmware "Adaptec RAID 5805 Firmware Build 18948" How to fix the problem? add Log Configuration summary Server name.....................raid_test Adaptec Storage Manager agent...7.31.00 (18856) Adaptec Storage Manager console.7.31.00 (18856) Number of controllers...........1 Operating system................Windows Configuration information for controller 1 ------------------------------------------------------- Type............................Controller Model...........................Adaptec 5805 Controller number...............1 Physical slot...................2 Installed memory size...........512 MB Serial number...................8C4510C6C9E Boot ROM........................5.2-0 (18948) Firmware........................5.2-0 (18948) Device driver...................5.2-0 (16119) Controller status...............Optimal Battery status..................Charging Battery temperature.............Normal Battery charge amount (%).......37 Estimated charge remaining......0 days, 16 hours, 12 minutes Background consistency check....Disabled Copy back.......................Disabled Controller temperature..........Normal (40C / 104F) Default logical drive task priorityHigh Performance mode................Dynamic Number of logical devices.......1 Number of hot-spare drives......0 Number of ready drives..........0 Number of drive(s) assigned to MaxCache cache0 Maximum drives allowed for MaxCache cache8 MaxCache Read Cache Pool Size...0 GB NCQ status......................Enabled Stay awake status...............Disabled Internal drive spinup limit.....0 External drive spinup limit.....0 Phy 0...........................No device attached Phy 1...........................No device attached Phy 2...........................No device attached Phy 3...........................1.50 Gb/s Phy 4...........................No device attached Phy 5...........................No device attached Phy 6...........................No device attached Phy 7...........................No device attached Statistics version..............2.0 SSD Cache size..................0 Pages on fetch list.............0 Fetch list candidates...........0 Candidate replacements..........0 69319...........................31293 Logical device..................0 Logical device name............. RAID level......................Simple volume Data space......................148,916 GB Date created....................09/19/2012 Interface type..................Serial ATA State...........................Optimal Read-cache mode.................Enabled Preferred MaxCache read cache settingEnabled Actual MaxCache read cache setting Disabled Write-cache mode................Enabled (write-back) Write-cache setting.............Enabled (write-back) Partitioned.....................Yes Protected by hot spare..........No Bootable........................Yes Bad stripes.....................No Power Status....................Disabled Power State.....................Active Reduce RPM timer................Never Power off timer.................Never Verify timer....................Never Segment 0.......................Present: controller 1, connector 0, device 0, S/N 9RX3KZMT Overall host IOs................99075 Overall MB......................4411203 DRAM cache hits.................71929 SSD cache hits..................0 Uncached IOs....................29239 Overall disk failures...........0 DRAM cache full hits............71929 DRAM cache fetch / flush wait...0 DRAM cache hybrid reads.........3476 DRAM cache flushes..............-- Read hits.......................0 Write hits......................0 Valid Pages.....................0 Updates on writes...............0 Invalidations by large writes...0 Invalidations by R/W balance....0 Invalidations by replacement....0 Invalidations by other..........0 Page Fetches....................0 0...............................0 73..............................10822 8...............................3 46138...........................4916 27184...........................15226 20875...........................323 16982...........................1771 1563............................5317 1948............................2969 Serial attached SCSI ----------------------- Type............................Disk drive Vendor..........................Unknown Model...........................ST3160815AS Serial Number...................9RX3KZMT Firmware level..................3.AAD Reported channel................0 Reported SCSI device ID.........0 Interface type..................Serial ATA Size............................149,05 GB Negotiated transfer speed.......1.50 Gb/s State...........................Optimal S.M.A.R.T. error................No Write-cache mode................Write back Hardware errors.................0 Medium errors...................0 Parity errors...................0 Link failures...................0 Aborted commands................0 S.M.A.R.T. warnings.............0 Solid-state disk (non-spinning).false MaxCache cache capable..........false MaxCache cache assigned.........false NCQ status......................Enabled Phy 0...........................1.50 Gb/s Power State.....................Full rpm Supported power states..........Full rpm, Powered off 0x01............................113 0x03............................98 0x04............................99 0x05............................100 0x07............................83 0x09............................75 0x0A............................100 0x0C............................99 0xBB............................100 0xBD............................100 0xBE............................61 0xC2............................39 0xC3............................69 0xC5............................100 0xC6............................100 0xC7............................200 0xC8............................100 0xCA............................100 Aborted commands................0 Link failures...................0 Medium errors...................0 Parity errors...................0 Hardware errors.................0 SMART errors....................0 End of the configuration information for controller 1 List item

    Read the article

  • One server, Two APC UPS on redundant power supplies : How to trigger shutdown ?

    - by Falken
    I have a server racked and its redundant power supplies plugged in two APC Smart-UPS 3000 XLM. Each UPS is connected to two different mains power sources. Two instances of apcupsd are running, each one connected to its own UPS. They can both detect when an UPS is on Battery, and each UPS can then trigger a shutdown on the server. Question is : How NOT to shutdown if ONLY ONE UPS runs out of battery ? Note : Smart-UPS 3000 XLM has a "Power Sync" Function that is able to connect to its peer and detect its status. But when I pulled the plug out of one of them, the Shutdown order was sent anyway. I'm thinking about modifying the shutdown scripts to check with "apcaccess" if the other ups is down. Any experience on this would be appreciated !

    Read the article

  • Considerations for a business looking to transition from PSTN to IP Telephony

    - by Bryce Thomas
    Full disclosure - This is related to a homework assignment question. I am not asking you to do my work for me, I am merely looking for some pointers and considerations to direct me in my further research. I have an assignment I'm working on where I've been given a scenario where a business wants to look into transitioning to using "Internet Telephone" as opposed to a traditional PSTN/PBX system and I need to write a report on it. I'm after some high level pointers from people, especially anyone that has been involved in a real life transition of this nature, on what some of the most important considerations are. These can be financial considerations, initial setup considerations, ongoing administrative considerations, quality of service considerations or anything else that is pertinent to performing such a transition.

    Read the article

  • When running a shell script, how can you protect it from overwriting or truncating files?

    - by Joseph Garvin
    If while an application is running one of the shared libraries it uses is written to or truncated, then the application will crash. Moving the file or removing it wholesale with 'rm' will not cause a crash, because the OS (Solaris in this case but I assume this is true on Linux and other *nix as well) is smart enough to not delete the inode associated with the file while any process has it open. I have a shell script that performs installation of shared libraries. Sometimes, it may be used to reinstall versions of shared libraries that were already installed, without an uninstall first. Because applications may be using the already installed shared libraries, it's important the the script is smart enough to rm the files or move them out of the way (e.g. to a 'deleted' folder that cron could empty at a time when we know no applications will be running) before installing the new ones so that they're not overwritten or truncated. Unfortunately, recently an application crashed just after an install. Coincidence? It's difficult to tell. The real solution here is to switch over to a more robust installation method than an old gigantic shell script, but it'd be nice to have some extra protection until the switch is made. Is there any way to wrap a shell script to protect it from overwriting or truncating files (and ideally failing loudly), but still allowing them to be moved or rm'd? Standard UNIX file permissions won't do the trick because you can't distinguish moving/removing from overwriting/truncating. Aliases could work but I'm not sure what entirety of commands need to be aliased. I imagine something like truss/strace except before each action it checks against a filter whether to actually do it. I don't need a perfect solution that would work even against an intentionally malicious script. Ideas I have so far: Alias cp to GNU cp (not the default since I'm on Solaris) and use the --remove-destination option. Alias install to GNU install and use the --backup option. It might be smart enough to move the existing file to the backup file name rather than making a copy, thus preserving the inode. "set noclobber" in ~/.bashrc so that I/O redirection won't overwrite files

    Read the article

  • Suppress log messages about 3ware disk temperature changes on CentOS?

    - by Stefan Lasiewski
    I have a number of CentOS 5 servers which use 3ware RAID controllers. These servers are bugging my team with messages about minor temperature changes, like this: Jun 8 12:32:39 HOST smartd[1231]: Device: /dev/twa0 [3ware_disk_01], SMART Usage Attribute: 194 Temperature_Celsius changed from 119 to 118 Jun 8 12:32:39 HOST smartd[1231]: Device: /dev/twa0 [3ware_disk_03], SMART Usage Attribute: 194 Temperature_Celsius changed from 122 to 121 How can I suppress these messages? According to man smartd.conf : To disable any of the 3 reports, set the corresponding limit to 0. Trailing zero arguments may be omitted. By default, all temperature reports are disabled (´-W 0´). On my systems, smartd is reporting about temperature changes by default. I tried a manual approach. In /etc/smartd.conf, I have the following: /dev/twa0 -d 3ware,1 -a -W 0 /dev/twa0 -d 3ware,3 -a -W 0 But this still does not suppress the messages. Since these messages show up in /var/log/messages, LogWatch is sending unnecessary emails every night.

    Read the article

  • Battery backed write cache behavior upon disk change

    - by Halfgaar
    We use 3ware Inc 9650SE SATA-II RAID PCIe RAID controllers with battery backed write cache. Our spare hardware has the same controller. I was wondering; are these controllers smart enough not to sync the cache when the disks have been changed? For example, if I deploy one of those spare machines by putting in the disks of another machine and that spare machine still has pending writes, will it be smart enough not to perform those writes on the replaced array? Edit: my scenario is not really made clear, so let me give an example: server1 goes down because of power supply failure. I put the disks in server2 and start. I repair server1 I put the disks back from server2 in server1 (it's not relevant right now that in reality I would probably keep server2 running). If server1 doesn't have safeguards, it will write to the array, thinking it's simply powering up again, corrupting it.

    Read the article

  • Adaptec 5805 not recognized after reboot

    - by Rakedko ShotGuns
    After rebooting the system, the controller is not recognized. It only works if the computer is shut down and turned off. I have recently updated the firmware to "Adaptec RAID 5805 Firmware Build 18948". How do I fix the problem? Configuration summary --------------------------- 1. Server name.....................raid_test Adaptec Storage Manager agent...7.31.00 (18856) Adaptec Storage Manager console.7.31.00 (18856) Number of controllers...........1 Operating system................Windows Configuration information for controller 1 ------------------------------------------------------- Type............................Controller Model...........................Adaptec 5805 Controller number...............1 Physical slot...................2 Installed memory size...........512 MB Serial number...................8C4510C6C9E Boot ROM........................5.2-0 (18948) Firmware........................5.2-0 (18948) Device driver...................5.2-0 (16119) Controller status...............Optimal Battery status..................Charging Battery temperature.............Normal Battery charge amount (%).......37 Estimated charge remaining......0 days, 16 hours, 12 minutes Background consistency check....Disabled Copy back.......................Disabled Controller temperature..........Normal (40C / 104F) Default logical drive task priority High Performance mode................Dynamic Number of logical devices.......1 Number of hot-spare drives......0 Number of ready drives..........0 Number of drive(s) assigned to MaxCache cache0 Maximum drives allowed for MaxCache cache8 MaxCache Read Cache Pool Size...0 GB NCQ status......................Enabled Stay awake status...............Disabled Internal drive spinup limit.....0 External drive spinup limit.....0 Phy 0...........................No device attached Phy 1...........................No device attached Phy 2...........................No device attached Phy 3...........................1.50 Gb/s Phy 4...........................No device attached Phy 5...........................No device attached Phy 6...........................No device attached Phy 7...........................No device attached Statistics version..............2.0 SSD Cache size..................0 Pages on fetch list.............0 Fetch list candidates...........0 Candidate replacements..........0 69319...........................31293 Logical device..................0 Logical device name............. RAID level......................Simple volume Data space......................148,916 GB Date created....................09/19/2012 Interface type..................Serial ATA State...........................Optimal Read-cache mode.................Enabled Preferred MaxCache read cache settingEnabled Actual MaxCache read cache setting Disabled Write-cache mode................Enabled (write-back) Write-cache setting.............Enabled (write-back) Partitioned.....................Yes Protected by hot spare..........No Bootable........................Yes Bad stripes.....................No Power Status....................Disabled Power State.....................Active Reduce RPM timer................Never Power off timer.................Never Verify timer....................Never Segment 0.......................Present: controller 1, connector 0, device 0, S/N 9RX3KZMT Overall host IOs................99075 Overall MB......................4411203 DRAM cache hits.................71929 SSD cache hits..................0 Uncached IOs....................29239 Overall disk failures...........0 DRAM cache full hits............71929 DRAM cache fetch / flush wait...0 DRAM cache hybrid reads.........3476 DRAM cache flushes..............-- Read hits.......................0 Write hits......................0 Valid Pages.....................0 Updates on writes...............0 Invalidations by large writes...0 Invalidations by R/W balance....0 Invalidations by replacement....0 Invalidations by other..........0 Page Fetches....................0 0...............................0 73..............................10822 8...............................3 46138...........................4916 27184...........................15226 20875...........................323 16982...........................1771 1563............................5317 1948............................2969 Serial attached SCSI ----------------------- Type............................Disk drive Vendor..........................Unknown Model...........................ST3160815AS Serial Number...................9RX3KZMT Firmware level..................3.AAD Reported channel................0 Reported SCSI device ID.........0 Interface type..................Serial ATA Size............................149,05 GB Negotiated transfer speed.......1.50 Gb/s State...........................Optimal S.M.A.R.T. error................No Write-cache mode................Write back Hardware errors.................0 Medium errors...................0 Parity errors...................0 Link failures...................0 Aborted commands................0 S.M.A.R.T. warnings.............0 Solid-state disk (non-spinning).false MaxCache cache capable..........false MaxCache cache assigned.........false NCQ status......................Enabled Phy 0...........................1.50 Gb/s Power State.....................Full rpm Supported power states..........Full rpm, Powered off 0x01............................113 0x03............................98 0x04............................99 0x05............................100 0x07............................83 0x09............................75 0x0A............................100 0x0C............................99 0xBB............................100 0xBD............................100 0xBE............................61 0xC2............................39 0xC3............................69 0xC5............................100 0xC6............................100 0xC7............................200 0xC8............................100 0xCA............................100 Aborted commands................0 Link failures...................0 Medium errors...................0 Parity errors...................0 Hardware errors.................0 SMART errors....................0 End of the configuration information for controller 1

    Read the article

  • Sporadic disk clicking sound

    - by Abdó
    Hi, I'm having some unusual and sporadic hard disk clicking issues. Here is a cronological description of the facts. I'm using an ASUS P6T-SE with Intel Core i7, 6Gb RAM 600W Power supply and ATI4670 graphics, running Ubuntu 10.10. About one month ago my hard disk (SATA II Seagate Barracuda 1Tb 7200 rpm) started making a clicking sound: a sort of loud tic-tac, every second or so, when involved in disk activity. The system was clearly slower than before at disk access, but it was functional and I could not find any signal of trouble on the linux logs. I disconnected the disk and tried an older SATA drive I had around: no problem with it. Then I reconnected the Seagate disk, and the problem was mysteriously gone. Ubuntu booted normally, usual speed, no clicking. A couple of weeks later, the problem reappeared. I tried disconnecting reconnecting (as it somehow solved the problem before) without luck. So, despite it was a rather new drive, I assumed it was a hardware issue, made backups and bought a new drive. The new drive is a SATA II Seagate Barracuda 1.5 Tb 7200 rpm. I installed both drives at the same time, with the intention of transferring my files from on to the other. To my surprise, when I booted the computer with both drives, both started making the clicking sound !! Even worse, I removed the old drive, leaving the unformated new drive connected, and booted from a LiveCD. It kept clicking ! Puzzled by this, I tried both drives on my laptop with a SATA to USB cable. At the moment I connected any of them, they made one or two unusual clicks and immediately stopped doing that and worked normally. The old drive I thought almost dead, was working like a charm as if nothing happened. Then I thought: "ok, it must be the motherboard. Let's try again". So, I reconnected the old drive to the ASUS P6T motherboard (the same cables and SATA port as before), and it worked as if nothing happened ! The problem was gone again. The new 1.5 Tb drive was also working ok: No clicking nor slowdown. So I left the old 1Tb disk connected and kept using the computer daily during 3 weeks, until today it happened again. Now I don't really know what to do or check. I'm not even sure if it is a hardware issue any more ! This is rather annoying as it seems it happens with a period of 2 or 3 weeks and I have no means of forcing it to happen. Does anyone have a clue of what can causes this behaviour or have any suggestions of things I should check when it happens again ? What I did today is checking some SMART parameters Error log: smartctl -l error /dev/sda. No errors Short selftest: smartctl -t short /dev/sda. No errors Disk Health check: smartctl -H /dev/sda. passed And here are the vendor specific parameters (smartctl -A /dev/sda) Which I'm not quite sure how to interpret. === START OF READ SMART DATA SECTION === SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 120 099 006 Pre-fail Always - 235962588 3 Spin_Up_Time 0x0003 095 095 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 187 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 072 060 030 Pre-fail Always - 16348045 9 Power_On_Hours 0x0032 096 096 000 Old_age Always - 3590 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 94 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 097 000 Old_age Always - 4295164029 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 070 057 045 Old_age Always - 30 (Lifetime Min/Max 19/31) 194 Temperature_Celsius 0x0022 030 043 000 Old_age Always - 30 (0 18 0 0) 195 Hardware_ECC_Recovered 0x001a 037 026 000 Old_age Always - 235962588 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 73950746906346 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 1832967731 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 3294986902 Any clue to this mystery will be really welcome. Thank you very much !!

    Read the article

  • HDD bad sectors with OS

    - by Michael Z
    I wonder is that possible for OS to make bad sectors on Hard Drive? Preface: I have bought new HDD on 1Tb WB Caviar Black. I have installed new OS on ext4 partition Ubuntu 12.04.1 LTS. After few days S.M.A.R.T. of the Ubuntu's Disk Utility show that my hard has bad sectors! I have checked on S.M.A.R.T. immediately after installing OS - all was OK. During new OS working I have noticed some strange with HDD - all OS was freezed from 20 sec to 1 min and I have heard like HDD's engine restarting. At the dmes I have found something like this: [40085.407947] ata1.00: device reported invalid CHS sector 0

    Read the article

  • Sync Banshee library data.

    - by Dom
    I use Banshee to organise my music, I particularly like its scoring system and I have smart playlists based on it. However, I have two versions of my music library, one on each of my computers. As one of the computers is small I only have a favourite set of songs on that computer rather than my whole collection. The computers are not on a local network, but I do use Ubuntu One for file sharing between them. Is there any way I can synchronise song data (play count, score, skip count ...) and playlist data (including smart playlists that include songs based on this data) between the two computers? This would only be relevant of course for the songs that exist on both computers, the songs that exist on only one would need to be ignored. I did consider putting the library data file (I think it is .xml but I'm not sure) into the shared file and creating a symbolic link to it, but then I wouldn't be able to have a different set of songs on each computer. Thank you.

    Read the article

  • Recover strategy single bad sector in moricon

    - by Damon
    This week, my harddisk made me an early christmas present in the form of a single defect sector. To make up for the puny size of the present, it chose a sector inside moricons.dll for that. This means that now the system takes about 5 minutes to boot before Windows gives up and moves on, and there's 2 dozen scary "critical failure" entries in the system log after every boot, which is annoying. OK, admittedly, I shouldn't complain, it could be worse, the bad sector could be in ntldr... SMART info more or less indicates (for what SMART can indicate anyway) that the drive is mostly OK. Soft Read Error Rate has a score of 96, and Current Pending Sector Count has a raw value of 8, which translates to a score of 100. Acronis DriveMonitor makes this an issue (lowering the overall rating to 75%), HDD Health calls it "excellent", giving an overall rating of 95% (which is what this harddisk from day one). No single score is below 95 (power on hours and spin up count), and most are 100 anyway. Well, whatever, I've seen drives with perfect SMART values fail from one second to the other, and drives with moderate values work for years. So, I'm inclined not to put too much weight into that overall. TL;DR Now... to the problem: I don't feel like trashing the disk just yet (that's planned with a new OS install upgrading to Win7 early next year, independently of this issue), but in the mean time, I would still like to have a smoothly running system again. Therefore, I feel tempted to tamper with it, but before I render my system entirely unusable (since I've never done this before), I'd like to verify that my planned procedere is likely to suceed in having a working system again: Copy moricons.dl_ from the Windows install disk, rename it to moricons.zip, and unzip it. This gives an intact 5.1.2600.2180 version (the broken one is 5.1.2600.5512 - but I guess this makes not much of a difference, since it's an icon-only DLL, and an outdated copy should work better than one that can't be read) Run chkdsk /r /f` which will "repair" the file (i.e. delete the file without asking, tell the drive to remap the sector, and toss some unreadable junk into a file with a hexadecimal number) Hopefully Windows still boots after this (is that a reasonable expectation, or do I need to have something like BartPE ready? -- but then again, what's that good for in case chkdsk has nuked the entire file system...) Delete the junk file generated by chkdsk, copy the new DLL to %windir%\system32 Reboot. Pray. Maybe I just shouldn't touch anything, since it still kind of works... if annoying, but it works. Unsure... But, is there anything fundamentally wrong with the planned approach? Is this a sensible approach at all?

    Read the article

  • Multiple WAPs: Bandwidth, Frequency Considerations

    - by Pete Cresswell
    The router in my LAN closet does 2 and 5 GHz. In the kitchen, I have a single-band 2 GHz WAP, and in the garden shed I have another single-band 2 GHz WAP. All are set to Bandwidth = 40 MHz, Wireless Network Mode = N-Only. The kitchen WAP and the LAN closet router both come up with multiple bars on my smart phone from almost anywhere in the house. The garden shed WAP will register one bar... but only sometimes. The Questions: Are these things in danger of butting heads? Should I re-set them to Bandwidth = 20 MHz? Bandwidth = Auto? Are there any tools that I could use on an Android smart phone, iPod, or WiFi-enabled laptop to make my own analysis?

    Read the article

  • Accidentally deleted the software for MyPassport Essential SE 1TB Hardrive

    - by user26192
    I'm posting for a friend of mine. She bought a WD MyPassport Essential SE 1 TB Hard drive the other day. When she plugged in the USB in her lap top, the driver cannot be recognized by the smart ware software. While she was doing a back up of her files, McAfee was running in the background. Since the backup was taking so long to finish, she decided to pause it. She tried to delete the partially backed up files, but instead, she accidentally deleted the entire file in the folder including the pre-installed software. Now, when she tries to start up the MyPassport, the smart ware doesn't show up anymore. Can someone please give us advice what can she do about this? Thank you.

    Read the article

  • Exchange and external mail server

    - by Bahrain Admin
    Hi, We have our domain hosted externally with Network Solutions, and our mail server is running from there. We have a branch office in Bahrain and have 3 users who would like to use their email addresses on a local exchange server running at the Bahrain office. The Exchange server is currently only used for internal mail,contacts and calendaring. I've used a third=party program to download the POP3 mail to their exchange accounts. so they can receive mail from outside. The issue is in sending mail using their external addresses. I've setup their exchange accounts to include their external address. But we get an error message stating that the IP is not authorized. I tried putting the local ISP as the smart host, but then we get an error message stating that the Address was rejected. I tried using our own external mail server as the smart host, but then the message "Relaying is denied" comes up. Any suggestions? Thanks Arun

    Read the article

  • Accidentally deleted the software for MyPassport Essential SE 1TB Hardrive

    - by user26192
    Hi, I'm posting for a friend of mine. She bought a WD MyPassport Essential SE 1 TB Hard drive the other day. When she plugged in the USB in her lap top, the driver cannot be recognized by the smart ware software. While she was doing a back up of her files, McAfee was running in the background. Since the backup was taking so long to finish, she decided to pause it. She tried to delete the partially backed up files, but instead, she accidentally deleted the entire file in the folder including the pre-installed software. Now, when she tries to start up the MyPassport, the smart ware doesn't show up anymore. Can someone please give us advice what can she do about this? Thank you.

    Read the article

  • WD: UDMA CRC Errors and Reallocated Sector

    - by Leo White
    I got a WD Caviar Black 1TB (WD1001FALS) and according to SMART, I got: one "Reallocated Sector" one "Reallocated Event" 26 UDMA CRC Errors in my drive but it's a "Pass" for the "SMART overall-health self assessment test". I think it's because of these, I'm having problems with Grub, and thus can't boot into any OS at all. Are these problems serious? According to "Warranty Services", my drive is still "In Limited Warranty". Would I be eligible for a replacement? FYI: I'm running Ubuntu 11.10. Any help will be appreciated. Thanks

    Read the article

  • Where are the function address literals in c++?

    - by academicRobot
    First of all, maybe literals is not the right term for this concept, but its the closest I could think of (not literals in the sense of functions as first class citizens). <UPDATE> After some reading with help from answer by Chris Dodd, what I'm looking for is literal function addresses as template parameters. Chris' answer indicates how to do this for standard functions, but how can the addresses of member functions be used as template parameters? Since the standard prohibits non-static member function addresses as template parameters (c++03 14.3.2.3), I suspect the work around is quite complicated. Any ideas for a workaround? Below the original form of the question is left as is for context. </UPDATE> The idea is that when you make a conventional function call, it compiles to something like this: callq <immediate address> But if you make a function call using a function pointer, it compiles to something like this: mov <memory location>,%rax callq *%rax Which is all well and good. However, what if I'm writing a template library that requires a callback of some sort with a specified argument list and the user of the library is expected to know what function they want to call at compile time? Then I would like to write my template to accept a function literal as a template parameter. So, similar to template <int int_literal> struct my_template {...};` I'd like to write template <func_literal_t func_literal> struct my_template {...}; and have calls to func_literal within my_template compile to callq <immediate address>. Is there a facility in C++ for this, or a work around to achieve the same effect? If not, why not (e.g. some cataclysmic side effects)? How about C++0x or another language? Solutions that are not portable are fine. Solutions that include the use of member function pointers would be ideal. I'm not particularly interested in being told "You are a <socially unacceptable term for a person of low IQ>, just use function pointers/functors." This is a curiosity based question, and it seems that it might be useful in some (albeit limited) applications. It seems like this should be possible since function names are just placeholders for a (relative) memory address, so why not allow more liberal use (e.g. aliasing) of this placeholder. p.s. I use function pointers and functions objects all the the time and they are great. But this post got me thinking about the don't pay for what you don't use principle in relation to function calls, and it seems like forcing the use of function pointers or similar facility when the function is known at compile time is a violation of this principle, though a small one. Edit The intent of this question is not to implement delegates, rather to identify a pattern that will embed a conventional function call, (in immediate mode) directly into third party code, possibly a template.

    Read the article

< Previous Page | 48 49 50 51 52 53 54 55 56 57 58 59  | Next Page >