Search Results

Search found 19191 results on 768 pages for 'core location'.

Page 54/768 | < Previous Page | 50 51 52 53 54 55 56 57 58 59 60 61  | Next Page >

  • Where Are Databases Located - MySQL File Location

    - by nicorellius
    I just installed a CRM application with a MySQL database. I thought I new the name of the database but I can't find it. Now I am trying to perform a mysqldump but I don't know the name of my database or where it's located. Most docs I read assume the admin knows where this database is located and thee name of it - I should know this, I know.

    Read the article

  • Fedora Core 11 won't boot without a monitor

    - by feihtthief
    I have a P4 system that I installed Fedora 11 on. It will not boot without a monitor attached. The monitor can be off (not even have power plugged in), but must be attached. Without a monitor the hard disk thrashes around a bit like it's starting up services, but does not get to the point where I can ssh into the box. I have set the default runlevel to 3 and removed the rhgb entry from grub. Any suggestions welcome. Edit: I have already set the run-level to 3. The machine boots up fine with the monitor plugged in to the point where I can SSH into it. as soon as i unplug the monitor and reboot, it will not boot to that point.

    Read the article

  • Location of lock screen

    - by ICTdesk.net
    Does anybody know if it is possible to change a setting so that the Windows XP Lock Screen is not centered, but let's say in right or left top/down corner or maybe even a give x or y coordinate?

    Read the article

  • Determine Location of Inode Usage

    - by Dave Forgac
    I recently installed Munin on a development web server to keep track of system usage. I've noticted that the system's inode usage is climbing by about 7-8% per day even though the disk usage has barely increased at all. I'm guessing something is writing a ton of tiny files but I can't find what / where. I know how to find disk space usage but I can't seem to find a way to summarize inode usage. Is there a good way to determine inode usage by directory so I can locate the source of the usage?

    Read the article

  • Windows 7: Moving Program Files location during install using unattend.xml

    - by Shevek
    I am planning on using an unattend.xml to create a Windows 7 Ultimate 64-bit setup with Users and ProgramData on a 2nd drive. I have found many samples of how to do this (see below). However I would also like to move Program Files to a 3rd drive as well. i.e.: C:\Windows [SSD] D:\Users [HDD1] D:\ProgramData [HDD1] P:\Program Files [HDD2] P:\Program Files (x86) [HDD2] I have found that this was possible using unattend.txt in XP but all documentation or examples I find about Win 7 only mention Users and ProgramData, not Program Files. Is this possible using an answer file? Sample unattend.xml for Users and ProgramData: <?xml version="1.0" encoding="utf-8"?> <unattend xmlns="urn:schemas-microsoft-com:unattend"> <settings pass="oobeSystem"> <component name="Microsoft-Windows-Shell-Setup" publicKeyToken="31bf3856ad364e35" language="neutral" versionScope="nonSxS" processorArchitecture="amd64"> <FolderLocations> <ProfilesDirectory>D:\Users</ProfilesDirectory> <ProgramData>D:\ProgramData</ProgramData> </FolderLocations> </component> </settings> </unattend>

    Read the article

  • Nagios core Event Handler not working

    - by sivashanmugam
    Nagios Event Handler is not triggering when the service is taking more time to response or down. My configuration in below nagios.cfg enable_event_handlers=1 localhost.cfg define service { use generic-service host_name Server service_description test-server servicegroups test-service check_command check-service is_volatile 0 check_period 24x7 max_check_attempts 4 normal_check_interval 2 retry_check_interval 2 contact_groups testcontacts notification_period 24x7 notification_options w,u,c,r notifications_enabled 1 event_handler_enabled 1 event_handler recheck-service } command.cfg define command{ command_name recheck-service command_line /usr/local/nagios/libexec/alert.sh $SERVICESTATE$ $SERVICESTATETYPE$ $SERVICEATTEMPT$ } alert.sh file !/bin/sh set -x case "$1" in OK) # The service just came back up, so don't do anything... ;; WARNING) # We don't really care about warning states, since the service is probably still running... ;; UNKNOWN) # We don't know what might be causing an unknown error, so don't do anything... ;; CRITICAL) Aha! The HTTP service appears to have a problem - perhaps we should restart the server... Is this a "soft" or a "hard" state? case "$2" in We're in a "soft" state, meaning that Nagios is in the middle of retrying the check before it turns into a "hard" state and contacts get notified... SOFT) # What check attempt are we on? We don't want to restart the web server on the first check, because it may just be a fluke! case "$3" in Wait until the check has been tried 3 times before restarting the web server. If the check fails on the 4th time (after we restart the web server), the state type will turn to "hard" and contacts will be notified of the problem. Hopefully this will restart the web server successfully, so the 4th check will result in a "soft" recovery. If that happens no one gets notified because we fixed the problem! 3) echo -n "Going To Ping the Virtual Machine (3rd soft critical state)..." # Call the init script to restart the HTTPD server myresult=`/usr/local/nagios/libexec/check_http xyz.com -t 100 | grep 'time'| awk '{print $10}'` echo "Your Service Is taking the following time Delay" "$myresult Seconds" |mail -s "WARNING : Service Taken More Time To Response" [email protected] ;; esac ;; # The HTTP service somehow managed to turn into a hard error without getting fixed. # It should have been restarted by the code above, but for some reason it didn't. # Let's give it one last try, shall we? # Note: Contacts have already been notified of a problem with the service at this

    Read the article

  • What happens when you add a Graphics card to a i7 with build in graphics (e.g. HD 4000)

    - by Matt
    I'm thinking of upgrading my computer from an AMD Phenom II X4 955BE with a AMD Radeon HD 6800 Graphics card (not integrated) to using a Intel Core i7 3770. As I have no knowledge of integrated graphics, my question is, what happens to the computing power when not using the HD4000 integrated graphics of the CPU (does it mean the CPU will run faster then it would if I relied on it?) Also what is better the CPUs inbuilt HD4000 or my Radeon Graphics card? I am mostly interested in terms of content creation: Using Adobe After Effects, 3D Rendering etc. Not too bothered about gaming performance. I will be using the spare parts of this build and older systems to make a second computer for network renders so what will be the advantages of keeping the Radeon with the current system for that?

    Read the article

  • Issue with https:// url going to an unknown location

    - by Brandon
    We have a website (ASP.NET/Plesk 9.5.5) that can be accessed just fine through the regular URL (http://example.com). However when accessing the site through https://example.com the site displays the invalid security certificate warning, which is fine since we don't have an SSL certificate. If I add an exception, I'm sent to a completely separate site that is apparently hosting a malware script (I'm still on https://example.com though). Because of this Google has flagged the site as dangerous. I can't find anything in the Plesk panel that would help fix this, and as far as I can tell those files don't exist on our server. How do I tell where the https:// link is sending me? I'm not that familiar with DNS, but is that what is causing this behavior?

    Read the article

  • Computer won't reboot without waiting for a while

    - by Benjamin
    I've got an unusual problem with my computer. When ever I reboot my computer it won't boot, I get a few beeps from the BIOS and nothing else, however if I wait for a few minuets the computer will boot perfectly. I tried to count the beeps and I get around 7-9 of them; the first two are noticeably closer together than the rest. [Edit: I'm now reasonably confident it's 1 long followed by 8 short beeps. That would be a display related issue: http://www.bioscentral.com/beepcodes/amibeep.htm] My BIOS is American Megatrends Inc and version P1.80, the Motherboard is an ASRock X58 Extreme (both according to dmidecode) Here's an output from LSPCI, I'm not sure what else might be useful but I can provide whatever's asked. 00:00.0 Host bridge: Intel Corporation 5520/5500/X58 I/O Hub to ESI Port (rev 13) 00:01.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 1 (rev 13) 00:03.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 3 (rev 13) 00:07.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 7 (rev 13) 00:14.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub System Management Registers (rev 13) 00:14.1 PIC: Intel Corporation 5520/5500/X58 I/O Hub GPIO and Scratch Pad Registers (rev 13) 00:14.2 PIC: Intel Corporation 5520/5500/X58 I/O Hub Control Status and RAS Registers (rev 13) 00:14.3 PIC: Intel Corporation 5520/5500/X58 I/O Hub Throttle Registers (rev 13) 00:1a.0 USB controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #4 00:1a.1 USB controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #5 00:1a.2 USB controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #6 00:1a.7 USB controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #2 00:1b.0 Audio device: Intel Corporation 82801JI (ICH10 Family) HD Audio Controller 00:1c.0 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 1 00:1c.1 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Port 2 00:1c.5 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 6 00:1d.0 USB controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #1 00:1d.1 USB controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #2 00:1d.2 USB controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #3 00:1d.7 USB controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #1 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev 90) 00:1f.0 ISA bridge: Intel Corporation 82801JIR (ICH10R) LPC Interface Controller 00:1f.2 SATA controller: Intel Corporation 82801JI (ICH10 Family) SATA AHCI Controller 00:1f.3 SMBus: Intel Corporation 82801JI (ICH10 Family) SMBus Controller 01:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 03) 02:00.0 FireWire (IEEE 1394): VIA Technologies, Inc. VT6315 Series Firewire Controller 02:00.1 IDE interface: VIA Technologies, Inc. VT6415 PATA IDE Host Controller (rev a0) 03:00.0 SATA controller: JMicron Technology Corp. JMB360 AHCI Controller (rev 02) 05:00.0 VGA compatible controller: nVidia Corporation GT200b [GeForce GTX 285] (rev a1) ff:00.0 Host bridge: Intel Corporation Xeon 5500/Core i7 QuickPath Architecture Generic Non-Core Registers (rev 05) ff:00.1 Host bridge: Intel Corporation Xeon 5500/Core i7 QuickPath Architecture System Address Decoder (rev 05) ff:02.0 Host bridge: Intel Corporation Xeon 5500/Core i7 QPI Link 0 (rev 05) ff:02.1 Host bridge: Intel Corporation Xeon 5500/Core i7 QPI Physical 0 (rev 05) ff:03.0 Host bridge: Intel Corporation Xeon 5500/Core i7 Integrated Memory Controller (rev 05) ff:03.1 Host bridge: Intel Corporation Xeon 5500/Core i7 Integrated Memory Controller Target Address Decoder (rev 05) ff:03.4 Host bridge: Intel Corporation Xeon 5500/Core i7 Integrated Memory Controller Test Registers (rev 05) ff:04.0 Host bridge: Intel Corporation Xeon 5500/Core i7 Integrated Memory Controller Channel 0 Control Registers (rev 05) ff:04.1 Host bridge: Intel Corporation Xeon 5500/Core i7 Integrated Memory Controller Channel 0 Address Registers (rev 05) ff:04.2 Host bridge: Intel Corporation Xeon 5500/Core i7 Integrated Memory Controller Channel 0 Rank Registers (rev 05) ff:04.3 Host bridge: Intel Corporation Xeon 5500/Core i7 Integrated Memory Controller Channel 0 Thermal Control Registers (rev 05) ff:05.0 Host bridge: Intel Corporation Xeon 5500/Core i7 Integrated Memory Controller Channel 1 Control Registers (rev 05) ff:05.1 Host bridge: Intel Corporation Xeon 5500/Core i7 Integrated Memory Controller Channel 1 Address Registers (rev 05) ff:05.2 Host bridge: Intel Corporation Xeon 5500/Core i7 Integrated Memory Controller Channel 1 Rank Registers (rev 05) ff:05.3 Host bridge: Intel Corporation Xeon 5500/Core i7 Integrated Memory Controller Channel 1 Thermal Control Registers (rev 05) ff:06.0 Host bridge: Intel Corporation Xeon 5500/Core i7 Integrated Memory Controller Channel 2 Control Registers (rev 05) ff:06.1 Host bridge: Intel Corporation Xeon 5500/Core i7 Integrated Memory Controller Channel 2 Address Registers (rev 05) ff:06.2 Host bridge: Intel Corporation Xeon 5500/Core i7 Integrated Memory Controller Channel 2 Rank Registers (rev 05) ff:06.3 Host bridge: Intel Corporation Xeon 5500/Core i7 Integrated Memory Controller Channel 2 Thermal Control Registers (rev 05) Update: ok I installed lm-sensors and here's the output. coretemp-isa-0000 Adapter: ISA adapter Core 0: +58.0°C (high = +80.0°C, crit = +100.0°C) Core 1: +59.0°C (high = +80.0°C, crit = +100.0°C) Core 2: +58.0°C (high = +80.0°C, crit = +100.0°C) Core 3: +57.0°C (high = +80.0°C, crit = +100.0°C) it8720-isa-0a10 Adapter: ISA adapter in0: +0.93 V (min = +0.00 V, max = +4.08 V) in1: +0.06 V (min = +0.00 V, max = +4.08 V) in2: +3.25 V (min = +0.00 V, max = +4.08 V) +5V: +2.91 V (min = +0.00 V, max = +4.08 V) in4: +3.04 V (min = +0.00 V, max = +4.08 V) in5: +2.94 V (min = +0.00 V, max = +4.08 V) in6: +2.14 V (min = +0.00 V, max = +4.08 V) 5VSB: +2.96 V (min = +0.00 V, max = +4.08 V) Vbat: +3.28 V fan1: 1869 RPM (min = 0 RPM) fan2: 0 RPM (min = 0 RPM) fan3: 0 RPM (min = 0 RPM) fan4: 1106 RPM (min = -1 RPM) fan5: 225000 RPM (min = -1 RPM) temp1: +39.0°C (low = +0.0°C, high = +127.0°C) sensor = thermistor temp2: +56.0°C (low = +0.0°C, high = +127.0°C) sensor = thermistor temp3: +127.0°C (low = +0.0°C, high = +127.0°C) sensor = thermistor cpu0_vid: +1.650 V intrusion0: ALARM If it helps here's the summery from sensors-detect Driver `it87': * ISA bus, address 0xa10 Chip `ITE IT8720F Super IO Sensors' (confidence: 9) Driver `adt7475': * Bus `NVIDIA i2c adapter 3 at 5:00.0' Busdriver `nvidia', I2C address 0x2e Chip `Analog Devices ADT7473' (confidence: 5) Driver `coretemp': * Chip `Intel digital thermal sensor' (confidence: 9)

    Read the article

  • Moving Temp folder location

    - by Chadworthington
    My C drive is a small SSD that I don't want to wear out or fill with unnecessary stuff. Is there any harm in moving the temp folder to another drive? I am under the impression that Windows will not need to look for files here, for example, in the case of uninstalls... Is this the case?

    Read the article

  • Why do some software not get load balanced even when there are multiple cores?

    - by Nav
    While VTune Analyzer was running on a blade server with 8 cores, I observed the cpu useage percentage using mpstat -P ALL 1. mpstat showed me that VTune was taking up 100% of a single core, while all other cores were idle. Why does that happen? Shouldn't the OS (RHEL Server 5.2) automatically distribute load across cores? The same happened when I tried running MATLAB (even after enabling multithreading support in the MATLAB settings). p.s: I'm a developer. Not a sys admin. So felt it better to ask here rather than at serverfault.

    Read the article

  • Which Processor should I buy: Intel Quad Core 2.5Ghz or Intel Core 2 Duo 2.9 Ghz?

    - by Kryten
    Hi, I am looking at buying a desktop and have narrowed down my choices to 2 machines with exactly the same specs, but different CPU's. Machine 1 CPU: Intel® Core™2 Quad Processor Q8300 (4M Cache, 2.50 GHz, 1333 MHz FSB) Machine 2 CPU: Intel® Core™2 Duo Processor E7500 (3M Cache, 2.93 GHz, 1066 MHz FSB) I plan on using the PC for the following: Music Playing Software Development Virtual Machine Running Gaming "General Work" Which CPU would better suit the job?

    Read the article

  • Virtual Windows Servers and Pagefile location [closed]

    - by Luke Puplett
    Considering that Windows makes heavy use of the pagefile even with huge amounts of RAM available, is it not best to have this pagefile on the fastest disk possible as close to the virtual systems as possible? I'm thinking, RAM disk. Where I work, storage for VMs is out on a NAS/SAN. I'm worried that so much memory access is having to go across the network! As a side, I think its about time MS got rid of paging and told us to buy more DIMMS. UPDATE So this question has been downvoted??! Accessing a local spindle is C40,000 times slower than a DIMM, so going over the network will be even slower for hard faults. I don't know why I got the downvote, I'm certain that this is an issue unless there's some other mechanism in ESX/HyperV that manages this.

    Read the article

  • How can I get a list of default documents in IIS using PowerShell?

    - by SGarratt
    I'm managing a Server Core machine and trying to do everything in PowerShell, which is fun. I need a list of the default documents. From other websites, I've found out how to set and remove them, using both xxx-WebConfiguration and xxx-WebConfigurationProperty. I've tried: Get-WebConfigurationProperty -Filter /system.webServer/defaultDocument -PSPath "IIS:\sites\Default Web Site" -Name files but it gives: Collection : {Microsoft.IIs.PowerShell.Framework.ConfigurationElement, Microsoft.IIs.PowerShell.Framework.Configuration Element, Microsoft.IIs.PowerShell.Framework.ConfigurationElement, Microsoft.IIs.PowerShell.Framework.Confi gurationElement...} ItemXPath : /system.webServer/defaultDocument Attributes : {} ChildElements : {} ElementTagName : files Methods : Schema : Microsoft.IIs.PowerShell.Framework.ConfigurationElementSchema which doesn't really help.

    Read the article

  • Make Safari 5's location bar more like Omnibox or AwesomeBar

    - by Lri
    When searching for history or favorites, the search phrase has to be an exact substring of the URL or title. For example super awesome wouldn't match this page. Can the criteria be made more liberal? When an item that was matched by its title is selected from the suggestion list, the title is filled in in place of the URL. The filled in part sometimes starts from the middle of a URL or a title. Can either of these behaviors be changed? Can you redirect unresolved addresses to the default search engine or a custom URL? In Firefox you can go to about:config and set keyword.URL to http://www.google.com/search?btnI&q=. Can you remove or hide the web search field? In Camino, Cruz, and Fluid it can be resized to zero width.

    Read the article

  • Installing Fedora Core 12 on a VPS

    - by cinqoTimo
    I'm working on a Linux VPS that is running FC6, and I want to reinstall with the latest version FC12. The VPS is running on the Virtuozzo platform. I am also running Plesk on the VPS. This is all managed hosting through Network Solutions, so I don't have access to the actual box. My question is, how does one reinstall a different OS through Virtuozzo? I see "reinstall VPS" in virtuozzo, but this just burns a fresh copy of FC6? Is this a host-by-host thing, or are there best practices for accomplishing this..?

    Read the article

  • Best VoIP VPS Location?

    - by ToiletOverflow
    Our office currently runs a few phones over a VoIP line. Through our VoIP provider, we have a virtual private server. We chose them as the VPS provider because the VPS came pre-loaded with all of the software that was necessary. However, I've discovered that I would rather manage the software myself and would prefer to work on a different platform. The primary reason that we have stayed with them is because as our VoIP provider, I presume that there is some advantage in call quality because they have "direct access to the PSTN", which I would presume is an advantage when it comes to call termination and overall call quality. My question boils down to: What is better from a call quality perspective? 1) A server located 20ms closer to us (60ms), offered by a different company. 2) The current server at the VoIP/SIP provider (80ms)

    Read the article

  • mySQL sphinx Index location on Ubuntu

    - by Marcus Morris
    I am trying to test out a Sphinx cookbook, but I need a database to do so. I have created the database locally, but I need to know where the default path is for the index of the table I created. This is the error I am currently getting when trying to run sphinx because the path to the index is wrong: WARNING: index 'phoneindex': preload: failed to open /var/lib/mysql/mysql.sph: No such file or directory; NOT SERVING FATAL: no valid indexes to serve Where can I find mysql.sph? Or how/when is that file created? Thanks!

    Read the article

  • Get the Windows Scheduler's Location Or Code?

    - by Ram
    Today i got a task to find the scheduler that is running once in a month, actually I have to change its running time period to once a week. I have searched for it in the Windows scheduled tasks, but i didn't find it. It is sending a mail containing a link. Now i am not confused about this where else can i find it. As the place i know where the scheduler can be, has already been checked by me. Can someone suggest me where else can i search for this scheduler? As per the previous developer's comment "It is a normal Windows method of scheduling tasks" UPDATE Actually the task is running after a month periodically. As per my knowledge it could be a "Windows Task Schedule" or "Windows Service" created by the old developer. Now as the previous developer is not available and i do not have any documentation.. i need to change the time period from month to weakly. I have checked in the "Task Schedules" on the server and checked the services running ob the server and was unable to find the "Scheduler". now i have two questions: is there any other approach by using that i can schedule an automated email periodically. any idea to find this.

    Read the article

  • why allow windows to disable one core? [closed]

    - by saber tabatabaee yazdi
    i teach MCITP for students and when describe about Disabling a Device Drivers , one of them ask me : why allow windows to disable drivers that windows need them? why windows allows to disable drivers, like disable cpu? like disabling graphic card? windows in many cases cant apply but allow to disabling CPU or etc. i am searching and find articles that describe how to disable CPU. but i am not Convinced WHY WE CAN DISABLE THESE drivers!!

    Read the article

  • Does Intel Smart Response provide any statistics on the cache usage?

    - by Tom Seddon
    I've set up my Z68-based Core i7 PC with a 60GB SSD dedicated as a Smart Response cache drive. Is there any way I can get any statistics out of it? It would be nice to have some information on how much cache space is actually being used, maybe how much of it was actually accessed recently, and how many reads in general are coming from the SSD rather than from the mechanical disk. These statistics might help to quickly provide some evidence for or against the use of Smart Response, without my having to reinstall Windows on the SSD (etc.) to find out. The Windows ReadyBoost feature has some performance counters you can access via the Windows 7 perfmon tool, for example, which is the kind of thing I'm hoping is somehow available. Smart Response provides no perfmon counters, though, and the Intel Rapid Storage Utility tells you pretty much nothing except that Smart Response is switched on.

    Read the article

  • Disable log rotation for apache or move file location

    - by vittocia
    I need to change the log retention for apache, currently is seems to be running on the default from logrotate.conf which is weekly. It creates 'access_log.1' 'access_log.2' and so on for each week. The problem is it deletes the last log file every week, 'access_log.5', I need the logs to keep going infinitely instead of the last log being deleted every week. It seems to be running on the default value from logrotate.conf - I don't want to change the default values held in that file, so I assume there is a way to change the retention using the /etc/logrotate.d/httpd file? the contents are as follows: /var/log/httpd/*log { missingok notifempty sharedscripts postrotate /sbin/service httpd reload > /dev/null 2>/dev/null || true endscript } what can I add/change to stop the last log being deleted every week?

    Read the article

< Previous Page | 50 51 52 53 54 55 56 57 58 59 60 61  | Next Page >