  • Migration of virtual Maschines

    - by Friedrich
    I wonder if there are tools for migrating from one virtual machine type to another. E.g let's say I have some Xen virtual maschine and like to make it run under KVM. I know that e.g in qeumu are tools which can be used to "migrate" such machines but how about e.g Xen - Kvm Kvm - Xen Xen - Vmware (server?)

    Read the article

  • Make VM Machine Name Visible to Host

    - by Agnel Kurian
    I have Ubuntu running in VMware Player. I am able to access an Apache instance on this VM by using the IP address but not by machine name. How do I make the name of the VM visible to the host? Edit: How do I add the machine name to my DNS? I am running within a Windows network.

    Read the article

  • error: The specified device is claimed by another driver (uvcvideo) on the host operating system

    - by kamal
    I am trying to run an ubuntu 11, in VMplayer 5 on an ubuntu 12.04 host, and when trying to run the guest, i get this error, and no display. The specified device is claimed by another driver (uvcvideo) on the host operating system. The device might be in use. To Continue, the device will first be disconnected from its current driver. I also found a sort of related comment ( RESOLVED ) on similar issue on: ubuntu forums

    Read the article

  • PERC H710 mini raid controller advanced settings (BIOS)

    - by gregg
    I upgraded from a PERC h310 to an H710 controller on my Dell R620 but didnt get any increase in performance. This is a ESXi host with a 5 disk RAID 5. I noticed when going to the RAID BIOS that the advanced settings section was not activated/checked off. In that section is the strip element size: 64kb (default) read policy: no read ahead and the write policy: write-through. Will checking that section do any harm to the existing raid array or will it simply enable those policies and hopefully boost performance? Or, lastly, is it already using those policies and the checkmark is simply to activate them for changes

    Read the article

  • ESXi hard drive power saving

    - by Jens
    I currently have a Windows Server running beneath my desk and was considering replacing it with a ESXi layer to run both a Windows and Unix virtual machine. The ESXi is going to give me some nice advantages that I can use but I am still stuck on this issue: The server is mainly used as a fileserver/local webserver, and I use Windows tasks to hibernate/wake the machine at night. Also there is an aggressive disk spin down timeout to reduce noise. With ESXi, this will not be possible to do any more. I could live with the server running 24/7, but I would really like to spin down the disks when not in use. Is there a way to do this on ESXi?

    Read the article

  • ESXi 4.1 host not recognising existing VMFS datastore

    - by Graeme Donaldson
    Existing setup: host1 and host2, ESX 4.0, 2 HBAs each. lun1 and lun2, 2 LUNs belonging to the same RAID set (my terminology might be sketchy here). This has been working just fine all along. I added host3, ESXi 4.1, 2 HBAs. If I view Configuration / Storage Adapters, I can see that both HBAs see both LUNs, but if I view Configuration / Storage, I only see 1 datastore. host1/2 can see both LUNs and I have VMs running on both too. I have rescanned, refreshed and even rebooted, but host3 refuses to acknowledge 1 of the datastores. Does anyone know what's going on? Update: I re-installed the host with ESX (not i) 4.0, same version as the existing hosts and it's still not recognising the vmfs. I think I'm going to SVmotion everything off that datastore then format it. Update2: I've created the LUN from scratch and the problem gets even weirder. I've presented the LUN to all 3 hosts, and I can see the LUN in the vSphere client's Configuration / Storage Adapters section on all 3 hosts. If I create a datastore on the LUN via the Configuration / Storage section on host1, it works fine and I can create an empty folder via datastore browser, but the datastore is not seen by the host2 and host3. I can use the Add Storage wizard on host2 and it will see the LUN. At this point the "VMFS Label" column has the label I gave with "(head)" appended. If I try the Add Storage wizard's "Keep the existing signature" option, it fails with an error "Cannot change the host configuration." and a dialog box that says 'Call "HostStorageSystem.ResolveMultipleUnresolvedVmfsVolumes" for object "storageSystem-17" on vCenter Server "vcenter.company.local" failed.' If I try the Add Storage wizard's "Assign a new signature" option on host2, it will complete and the VMFS label will have "snap-(hexnumber)-" prepended. At this point its also visible on host3, but not host1. I have a similar setup in a different datacenter which didn't give me all this trouble.

    Read the article

  • Connecting Dell PowerVault NAS to ESXi

    - by Matt Fitz
    Just got a Dell PowerVault NAS storage device running Windows Storage Server Standard which includes NFS. When I try and connect the ESXi server I get the following message: Call "HostDatastoreSystem.CreateNasDatastore" for object "ha-datastoresystem" on ESXi "powerhouse" failed. Operation failed, diagnostics report: Unable to complete Sysinfo operation. Please see the VMkernel log file for more details. I am pretty sure it is a username/password type thing. Not sure were to begin though. Also, I am planning on using "Username Mapping" instead of Active Directory. Any ideas would be greatly appreciated

    Read the article

  • ESXI 4 IPMI 2.0 - Cannot connect to IPMI after boot past bios

    - by adamflavell
    Dear All, I would appreciate any help here. I have a Supermicro 6016T-NTRF running ESXI 4 fine. The health monitors are showing up so ESXI is picking up the IPMI status. But I cannot connect to the host remotely via the dedicated IPMI nic. When the machine is in bios section I CAN connect but as soon as ESXI starts to boot I get blocked. Supermicro say the issue must be that ESXI is blocking the IPMI ports. How can this be corrected? I have read that there is no firewall on ESXI 4. Thanks, Adam

    Read the article

  • ESXi and Windows Server CPU parking

    - by Chris J
    For those that don't know, CPU parking is a feature in recent Windows Server releases that allows Windows to pretty much drop a CPU core to zero use, and having nothing use it. It's been introduced as a power-saving measure. There's more detail about it here, amongst other places. However what I'm curious about is whether this matter on a virtualised guest - or is CPU parking more of a hindrance than a help, given that the physical CPUs are managed by ESXi, not Windows, and that a parked CPU is less likely to deal with traffic unless the scheduler deems there's enough work to unpark the CPU? I've not found anything about this - I do suspect it will be very much based on a given workload, but I've not seen any discussion (unlike, say, whether hyper-threading has any effect, which seems to be discussed regularly). Whilst I do understand the "test with your workload" I was wondering if there was any advice/guidelines out there that I've missed.

    Read the article

  • conversion of a VMDK image with qemu-img failed with "error while reading sector 131072: Invalid argument"

    - by Erik Sjölund
    I tried to convert a VMDK image found in a OVA file to the QCOW2 format with the qemu-img command but it failed with the error message qemu-img: error while reading sector 131072: Invalid argument user@ubuntu:/tmp$ wget ftp://ftp.sanger.ac.uk/pub/databases/Pfam/vm/PfamWeb_20120124.ova user@ubuntu:/tmp$ tar xfv PfamWeb_20120124.ova PfamWeb_20120124_2.ovf PfamWeb_20120124_2.mf PfamWeb_20120124_2-disk1.vmdk user@ubuntu:/tmp$ qemu-img convert -O qcow2 PfamWeb_20120124_2-disk1.vmdk PfamWeb_20120124_2.qcow2 qemu-img: error while reading sector 131072: Invalid argument user@ubuntu:/tmp$ qemu-img --version | grep "qemu-img version" qemu-img version 1.0, Copyright (c) 2004-2008 Fabrice Bellard user@ubuntu:/tmp$ dpkg-query -f='${Version}\n' --show qemu-utils 1.0+noroms-0ubuntu14.1 user@ubuntu:/tmp$ cat /etc/issue Ubuntu 12.04.1 LTS \n \l How do I avoid the error?

    Read the article

  • Problems with 2 ISCSI connections esxi 3.5

    - by rphilli5
    I am running a dell poweredge 1950 with 4 nic cards. 1 is bonded to SAN #1 on 192.168.90.xx. The second SAN is on a separate network - 192.168.7.xx The network adapter can view the ip range of the san and the NIC can be pinged from 192.168.7.xx range. vswitch1 and vswitch2 are configured identically except for the ip address. The second SAN has been added to the iscsi software adapter but the SAN is never recognized. I can connect to the SAN from other machines on the local network. Is there something else that needs to be configured for the iscsi software adapter to know which vswitch to use?

    Read the article

  • Issues with doing a P2V on Exchange 2007

    - by PokermUNKEE
    I shutdown all Exchange services on the physical box and did a convert. Everything converted fine. Server booted up no issues and I could receive email from the outside world with no issues. But I am unable to send emails internally or externally. They just sit in the Outbox. I also disabled the DHCPClient service as I didn't want the server to get an IP address from DHCP when it first came online. It came online with no IP, then I used console to assign the correct static IP address (same one on the physical server) and rebooted. I ran the Exchange Troubleshooting Agent and it gave me the following errors: The value for the '\MSExchangeIS Mailbox\Messages Queued For Submission' counter on server exchange is greater than zero (average value is 8.8) and it appears that 'MSExchangeMailSubmission' is failing to submit messages to at least one computer with the Hub Transport server role installed over the last minute. Found 1 computers with the Hub Transport server role installed in the same Active Directory site as server exchange using local Active Directory site GUID 'ce8a4367-1bf6-4825-9cac-c4e2b115c450'. Check Local Active Directory Site Hub Transport Server Role Health (Mailflow_CheckLocalBhHealth1.1.1.1.1.1.1.1) I have one Exchange server with all the roles on it. Has anyone see this before when doing a convert? Please help :(

    Read the article

  • ESXi 5.5 on unlisted AMD A10 6800K possible?

    - by Erik
    I've done some initial googling.. and found AMD's A10 6800K supports virtualization via AMD-V. I'd like to install ESXI 5.5 on a USB thumbdrive to drive two+ VM's running Lubuntu. Has anyone seen the AMD A10 APU line used for baremetal hosting? AMD A10 APU 6800K 8GB DDR3 non ECC RAM 350GB HDD old spin drive (Sata I?III? unknown) I want to get started but afraid I'll wipe my current linux instance if it goes bad.

    Read the article

  • All paths down on vSphere esxi 5.1, LSI 9211-8i

    - by user1434058
    Works 100% ESXi 5.1 HBA (LSI 1064e) 1x SAS2 100GB SSD Doesn't work ESXi 5.1 HBA (LSI 9211-8i IT /IBM M1015) 1x SAS2 100GB SSD After a few hours of heavy HD load i get: - Device or filesystem with identifier ['all drives'] has entered the All Paths Down state. - ESXi retries but loses connectivity to the SAS drive, marks it as "dead or error" - reboot fixes the issue How can i fix this issue?

    Read the article

  • Download HP Power Protector for ESXi

    - by Mark Henderson
    The HP PowerProtector user guide states that to install the HP PowerProtector client on an ESXi Host: Download the latest version of HPPP from the HP website (http://www.hp.com/go/rackandpower). The ESXi Server is automatically detected, and a shutdown command script is generated. However in typical HP fashion, after clicking through no less than 6 different links to get to the downloads page, I am presented with: http://h18004.www1.hp.com/products/servers/proliantstorage/power-protection/software/power-protector/pp-dl.html HP Power Protector (HPPP) - Windows HP Power Protector (HPPP) - Linux x86 HP Power Protector (HPPP) - Linux x64 HP Power Protector (HPPP) - Linux IA64 HP Power Protector (HPPP) - HPUX The Linux packages contain an RPM and in no way resemble what is in the HP documentation. None of these are labelled for ESXi. Does anyone know where or how to get the HP Power Protector ESXi client installed?

    Read the article

  • kickstart: reference floppy drive via %ksappend or %include

    - by virtualeyes
    Having trouble getting %ksappend or %include to work when referencing a local floppy drive. Booting off remote server's cd-rom drive I am able to load the CentOS 6 minimal install image, and then add ks=hd:fd0/ks-jvm.cfg to boot params to load kickstart init file from floppy disk. That works fine. The problem is that I want to load a streamlined generic init file off the floppy and then, within the init, %ksappend or %include specific config files relative to the type of server I'm building (JVM, MySQL, Apache, etc.) I do not have DHCP, networking needs to be specified statically, so %ksappend and %include both fail when attempting to reference http://some-LAN-IP/foo.cfg since networking has not yet been set. The kickstart setup only works when I glob in the entire config into a single file, which is great, but ugly and difficult to maintain when I return later, having forgotten the original setup. At this point I'd be happy if I could get %ksappend or %include working with a floppy drive reference in the %post section; that would consolidate a lot of common boilerplate that all kickstarts will rely on (sshd_config, rsync config, resolve.conf, and so on) Thanks for providing the magic floppy drive reference that is eluding me!

    Read the article

  • networking through openstack installed on vm

    - by Mandar Katdare
    I am trying to set up a test installation of Openstack on a Ubuntu 12.04 VM running on a ESXi server. So far I have been able to launch the VMs on the ESXi, however am unable to assign IP addresses to them. As the VM with the Openstack installation has a single public IP, I wish to assign IPs to the VMs create through Openstack so that they can directly interact with the public network itself without having a separate private network. So I feel that bridging would not be the correct option here. But am unable to find the correct documents to go ahead with such an install. My ifconfig looks as follows: eth0 Link encap:Ethernet HWaddr 00:0c:29:6f:8a:d7 inet addr:192.168.4.167 Bcast:192.168.4.255 Mask:255.255.255.0 inet6 addr: fe80::20c:29ff:fe6f:8ad7/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:391640 errors:33 dropped:98 overruns:0 frame:0 TX packets:545044 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:40303931 (40.3 MB) TX bytes:763127348 (763.1 MB) Interrupt:18 Base address:0x2000 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:146127 errors:0 dropped:0 overruns:0 frame:0 TX packets:146127 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:799815763 (799.8 MB) TX bytes:799815763 (799.8 MB) virbr0 Link encap:Ethernet HWaddr 8a:80:33:32:63:a0 UP BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) The eth0 is the adapter that I intend to use for all communication. My nova.conf looks as follows: --dhcpbridge_flagfile=/etc/nova/nova.conf --dhcpbridge=/usr/bin/nova-dhcpbridge --logdir=/var/log/nova --state_path=/var/lib/nova --lock_path=/var/lock/nova --allow_admin_api=true --use_deprecated_auth=false --auth_strategy=keystone --scheduler_driver=nova.scheduler.simple.SimpleScheduler --s3_host=192.168.4.167 --ec2_host=192.168.4.167 --rabbit_host=192.168.4.167 --cc_host=192.168.4.167 --nova_url=http://192.168.4.167:8774/v1.1/ --routing_source_ip=192.168.4.167 --glance_api_servers=192.168.4.167:9292 --image_service=nova.image.glance.GlanceImageService --iscsi_ip_prefix=192.168.4 --sql_connection=mysql://novadbadmin:[email protected]/nova --ec2_url=http://192.168.4.167:8773/services/Cloud --keystone_ec2_url=http://192.168.4.167:5000/v2.0/ec2tokens --api_paste_config=/etc/nova/api-paste.ini --libvirt_type=kvm --libvirt_use_virtio_for_bridges=true --start_guests_on_host_boot=true --resume_guests_state_on_host_boot=true --vnc_enabled=true --vncproxy_url=http://192.168.4.167:6080 --vnc_console_proxy_url=http://192.168.4.167:6080 # network specific settings --network_manager=nova.network.manager.FlatDHCPManager --public_interface=eth0 --vmwareapi_host_ip=192.168.4.254 --vmwareapi_host_username=**** --vmwareapi_host_password=**** --vmwareapi_wsdl_loc=http://127.0.0.1:8080/wsdl/vim25/vimService.wsdl --fixed_range=192.168.4.190/24 --floating_range=192.168.4.190/24 --network_size=32 --flat_network_dhcp_start=192.168.4.190 --flat_injected=False --force_dhcp_release --iscsi_helper=tgtadm --connection_type=vmwareapi --root_helper=sudo nova-rootwrap --verbose --libvirt_use_virtio_for_bridges --ec2_private_dns_show --novnc_enabled=true --novncproxy_base_url=http://192.168.4.167:6080/vnc_auto.html --vncserver_proxyclient_address=192.168.4.167 --vncserver_listen=192.168.4.167 192.168.4.167 is my VM with the Openstack installation and 192.168.4.254 is my ESXi server on which the VM runs. Can anyone advice me about how to proceed? Thanks, Mandar

    Read the article

  • VMFS recovery - how do you proceed?

    - by ToreTrygg
    The more I look into ESX the more often i have to handle cases where the partition table of a disk with a VMFS volume gets corrupted. The reasons for this can be * idiot user * failed update * power failure * .... I guess you guys must already have something like a usual procedure on how to work through this cases. I am especially interested in a straight fast way to find out if the VMFS volume itself is corrupted beyond repair. So far I use very time consuming attempts with scans with Testdisk and similar tools. Do you have better / faster ways ?

    Read the article

  • How do the Virtual machine network works ?

    - by Arpit
    I wish to know If I am using 2 VM instance on the same setup and I wish to use heavy data flow between the VMs is there any possibility that I get the Timeout (let say I having one timer on the sending end which stops on getting the ack.) I vague question is How network works in VM . I hope I am clear with the question.

    Read the article

  • Very High Interrupt CPU usage in Win2k3 VM on vSphere

    - by Darragh
    Hi, I've been testing some software in a server virtual environment and I've noticed I get a huge amount of CPU usage on the Interrupts process. My question is, how does this relate to the virtual hardware platform as the rate is allot lower in a real system. Some how the hypervizor scheduler works hard to over come this problem but not as well as on real hardware does. Obvious things are high I/O and disk access but this application mostly just sits and works in memory allot. If anyone has experienced the same, please let me know. thanks in advance Screenshot: Process Explorer

    Read the article

  • SAN Replication for Fault tolerance using EVA4400

    - by Sergei
    Hi Everyone, I hope that someone would point me in the correct direction - it looks like I have no enough konwledge in the subject and timeframes are too tight for me to explore different scenarios in depth.. We have two datacenters few miles away from each other connected by 100 Mbps link.Each datacenter will have 5 BL490 blades with ESX Standard hosting about 50 VMs. Eac hsite has HP eva4400 SAN with SAN replication set up.VC is going to be in the first datacenter and both datacenter are networked. SAN Replication is block level so it seems like I cannot just replicate changes but all writes would have to be replicated.This should not be a problem as link can sustain about 1.8 TB a dayand data can be buffered. I am having trouble however visioning how recovery would work in this case.We don't need instant recovery , I would say 4 hours recovery time is accepted so fancy automatic SRM like DR scenario would not be easily accepted due to the financial reasons, however any comments are welcomed. Current idea is following: replicate LUNs from primary site to the secondary.When disaster strikes, IT personnel switches on ESX hosts on the remote side and connects replicated LUNS to them, then registers VMs and changes IP address. I understand that this seems like horribly manual process and I almost sure I have missed some obvious pitfalls here. Could someone let me know what direction should I go?An articles regarding the subject? This is a brand new setup and we would rather build up basic recovery process and scale it later.I just need to have a right direction to allow for such scalability. Thank you very much in advance!

    Read the article