  • Arch Linux: eth0 no carrier - network fails at boot

    - by user905686
    The problem My computer is connected to a network where dhcp is required. So my network configuration in /etc/rc.conf looks like interface=eth0 address= netmask= broadcast= gateway= My deamons are DAEMONS=(!hwclock syslog-ng network netfs crond ntpd) With this configuration, Arch hangs at boot a long time at "Network" (Still it says "[done]", but after boot I have no connection). I found out two workaround: Workaround 1 remove network from deamons run mii-tool --reset eth0 and dhcpcd eth0 after boot (somehow it does not work when placing these commands in /etc/rc.local. Then dhcp work very quickly (because of the reset!). Before executing the first command, ip link show eth0 has "NO CARRIER" in output. Afterwards, it doesn´t. (Also, mii-tool first shows "no link", afterwards eth0: 10 Mbit, half duplex, link ok. Workaround 2 Change network configuration to interface=eth0 address=x.y.z.21 netmask=255.255.255.0 broadcast=xxx.y.z.255 gateway=x.y.z.254 whereas x, y, z build the specific adresses of the network (Though dhcp is used, I get a static ip). Add the commands mii-tool --reset eth0 and dhcpcd eth0 to /etc/rc.local Now network starts quickly at boot (though I don´t know if successfully), the commands in /etc/rc.local are executed and the connection is fine after login. What to do? So the problem seems to be that dhcpcd stucks at "wating for carrier" or sth. I do not like the workaround, because some deamons need network (though they seem to start). What can I do to have eth0 ready for dhcp at boot? Or is there another problem?

    Read the article

  • How to auto syncronize files with network drive on Windows XP?

    - by stephenmm
    Windows XP: I would like to auto synchronize files between a a local drive and a network drive. I am aware of Windows Briefcase but it is very slow and I have to tell it to synchronize. I really like the way Dropbox does there synchronization as it is almost instantaneous. It is very impressive. I would just use Dropbox but I cannot install it on the remote machine. Is there some tool or script I can create that will watch a particular folder for any changes and then sync those changes to the networked drive automatically and nearly instantaneously? CLARIFICATION: I would like this tool/script to to be a daemon that starts when windows starts and continually monitors a folder for any changes to its contents. Once it observes changes in the source or the destination it synchronizes the files that changed (Very similar to the way Dropbox works). I have a good idea about how I would do this in a Perl script and if a tool does not exist that does this I will write it myself in Perl. If someone has already done this can they share the script?

    Read the article

  • ubuntu 12.04 kvm virtual server network setup, can't get the machine to be connectable

    - by xyious
    I have worked on my Ubuntu Server host for weeks now and I just can not manage to get the virtual machines into the network.... here's what I need to do: I need to be able to create virtual machines that have IP addresses that can be reached from the outside (192.168 network). I need to be able to connect to the virtual machines through ssh, ftp, http and preferably https, anything else doesn't matter that much. So far everything seems simple enough and I have a lot of leeway in terms of IP address range and server/client configuration. I have the option of taking part of a /24 net as most IPs aren't used, and if it's absolutely necessary I have the option of creating a new /24 subnet. Also have the option of reformatting and reinstalling OS on the host and recreating the virtual machines as nothing has been done other than trying to get virtual machines to work. I would prefer if the virtual machines were just part of the normal network which would be 192.168.5.0/24. The host machine has 2 network cards so I don't even necessarily need the Host to be connectable in the same /24 network. I have tried (I think) just about everything from about 5 different tutorials on bridging (giving br0 the same IP that eth0 used to have (Host is able to connect to VM and vice versa, VM doesn't have outside network access), having eth0 set up like it always was and having br0 have a different IP (same as above), NAT with port forwarding (which I would have preferred not to use but will if it works), turning off one of the hosts network cards and just using one of them, different subnets.... etc. I do know my way around iptables fairly well.... Host is 64bit Ubuntu Server 12.04, using libvirt/kvm. edits: Local network is 192.168.5.0/24, host has static ip 192.168.5.254, GW .5.1 which is also nameserver. We have a second Local network at 192.168.10.0/24 with .10.1 GW, but both hosts and VMs were supposed to go into the .5 subnet. The .10 subnet isn't required, but it wouldn't be horrible if the Host were only accessible in the .10 subnet.

    Read the article

  • Share a Printer on Your Network from Vista or XP to Windows 7

    - by Mysticgeek
    The other day we looked at sharing a printer between Windows 7 machines, but you may only have one Windows 7 machine and the printer is connected to a Vista or XP computer. Today we show you how to share a printer from either Vista or XP to Windows 7. We previously showed you how to share files and printers between Windows 7 and XP. But what if you have a printer connected to an XP or Vista machine in another room, and you want to print to it from Windows 7? This guide will walk you through the process. Note: In these examples we’re using 32-bit versions of Windows 7, Vista, and XP on a basic home network. We are using an HP PSC 1500 printer, but keep in mind every printer is different so finding and installing the correct drivers will vary. Share a Printer from Vista To share the printer on a Vista machine click on Start and enter printers into the search box and hit Enter. Right-click on the printer you want to share and select Sharing from the context menu. Now in Printer Properties, select the Sharing tab, mark the box next to Share this printer, and give the printer a name. Make sure the name is something simple with no spaces then click Ok. Share a Printer from XP To share a printer from XP click on Start then select Printers and Faxes. In the Printers and Faxes window right-click on the printer to share and select Sharing. In the Printer Properties window select the Sharing tab and the radio button next to Share this printer and give it a short name with no spaces then click Ok. Add Printer to Windows 7 Now that we have the printer on Vista or XP set up to be shared, it’s time to add it to Windows 7. Open the Start Menu and click on Devices and Printers. In Devices and Printers click on Add a printer. Next click on Add a network, wireless or Bluetooth printer. Windows 7 will search for the printer on your network and once its been found click Next. The printer has been successfully added…click Next. Now you can set it as the default printer and send a test page to verify everything works. If everything is successful, close out of the add printer screens and you should be good to go.   Alternate Method If the method above doesn’t work, you’ll can try the following for either XP or Vista. In our example, when trying to add the printer connected to our XP machine, it wasn’t recognized automatically. If you’re search pulls up nothing then click on The printer that I want isn’t listed. In the Add Printer window under Find a printer by name or TCP/IP address click the radio button next to Select a shared printer by name. You can either type in the path to the printer or click on Browse to find it. In this instance we decided to browse to it and notice we have 5 computers found on the network. We want to be able to print to the XPMCE computer so we double-click on that. Type in the username and password for that computer… Now we see the printer and can select it. The path to the printer is put into the Select a shared printer by name field. Wait while Windows connects to the printer and installs it… It’s successfully added…click Next. Now you can set it as the default printer or not and print a test page to make sure everything works successfully. Now when we go back to Devices and Printers under Printers and Faxes, we see the HP printer on XPMCE. Conclusion Sharing a printer from one machine to another can sometimes be tricky, but the method we used here in our setup worked well. Since the printer we used is fairly new, there wasn’t a problem with locating any drivers for it. Windows 7 includes a lot of device drivers already so you may be surprised on what it’s able to install. Your results may vary depending on your type of printer, Windows version, and network setup. This should get you started configuring the machines on your network—hopefully with good results.  If you you have two Windows 7 computers, then sharing a printer or files is easy through the Homegroup feature. You can also share a printer between Windows 7 machines on the same network but not Homegroup. Similar Articles Productive Geek Tips Share a Printer Between Windows 7 Machines Not in the Same HomegroupShare Files and Printers between Windows 7 and XPHow To Share Files and Printers Between Windows 7 and VistaEnable Mapping to \HostnameC$ Share on Windows 7 or VistaUse the Homegroup Feature in Windows 7 to Share Printers and Files TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 PCmover Professional Enable Check Box Selection in Windows 7 OnlineOCR – Free OCR Service Betting on the Blind Side, a Vanity Fair article 30 Minimal Logo Designs that Say More with Less LEGO Digital Designer – Free Create a Personal Website Quickly using Flavors.me

    Read the article

  • Share a Printer on Your Network from Vista or XP to Windows 7

    - by Mysticgeek
    The other day we looked at sharing a printer between Windows 7 machines, but you may only have one Windows 7 machine and the printer is connected to a Vista or XP computer. Today we show you how to share a printer from either Vista or XP to Windows 7. We previously showed you how to share files and printers between Windows 7 and XP. But what if you have a printer connected to an XP or Vista machine in another room, and you want to print to it from Windows 7? This guide will walk you through the process. Note: In these examples we’re using 32-bit versions of Windows 7, Vista, and XP on a basic home network. We are using an HP PSC 1500 printer, but keep in mind every printer is different so finding and installing the correct drivers will vary. Share a Printer from Vista To share the printer on a Vista machine click on Start and enter printers into the search box and hit Enter. Right-click on the printer you want to share and select Sharing from the context menu. Now in Printer Properties, select the Sharing tab, mark the box next to Share this printer, and give the printer a name. Make sure the name is something simple with no spaces then click Ok. Share a Printer from XP To share a printer from XP click on Start then select Printers and Faxes. In the Printers and Faxes window right-click on the printer to share and select Sharing. In the Printer Properties window select the Sharing tab and the radio button next to Share this printer and give it a short name with no spaces then click Ok. Add Printer to Windows 7 Now that we have the printer on Vista or XP set up to be shared, it’s time to add it to Windows 7. Open the Start Menu and click on Devices and Printers. In Devices and Printers click on Add a printer. Next click on Add a network, wireless or Bluetooth printer. Windows 7 will search for the printer on your network and once its been found click Next. The printer has been successfully added…click Next. Now you can set it as the default printer and send a test page to verify everything works. If everything is successful, close out of the add printer screens and you should be good to go.   Alternate Method If the method above doesn’t work, you’ll can try the following for either XP or Vista. In our example, when trying to add the printer connected to our XP machine, it wasn’t recognized automatically. If you’re search pulls up nothing then click on The printer that I want isn’t listed. In the Add Printer window under Find a printer by name or TCP/IP address click the radio button next to Select a shared printer by name. You can either type in the path to the printer or click on Browse to find it. In this instance we decided to browse to it and notice we have 5 computers found on the network. We want to be able to print to the XPMCE computer so we double-click on that. Type in the username and password for that computer… Now we see the printer and can select it. The path to the printer is put into the Select a shared printer by name field. Wait while Windows connects to the printer and installs it… It’s successfully added…click Next. Now you can set it as the default printer or not and print a test page to make sure everything works successfully. Now when we go back to Devices and Printers under Printers and Faxes, we see the HP printer on XPMCE. Conclusion Sharing a printer from one machine to another can sometimes be tricky, but the method we used here in our setup worked well. Since the printer we used is fairly new, there wasn’t a problem with locating any drivers for it. Windows 7 includes a lot of device drivers already so you may be surprised on what it’s able to install. Your results may vary depending on your type of printer, Windows version, and network setup. This should get you started configuring the machines on your network—hopefully with good results.  If you you have two Windows 7 computers, then sharing a printer or files is easy through the Homegroup feature. You can also share a printer between Windows 7 machines on the same network but not Homegroup. Similar Articles Productive Geek Tips Share a Printer Between Windows 7 Machines Not in the Same HomegroupShare Files and Printers between Windows 7 and XPHow To Share Files and Printers Between Windows 7 and VistaEnable Mapping to \HostnameC$ Share on Windows 7 or VistaUse the Homegroup Feature in Windows 7 to Share Printers and Files TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 PCmover Professional Enable Check Box Selection in Windows 7 OnlineOCR – Free OCR Service Betting on the Blind Side, a Vanity Fair article 30 Minimal Logo Designs that Say More with Less LEGO Digital Designer – Free Create a Personal Website Quickly using Flavors.me

    Read the article

  • Find only physical network adapters with WMI Win32_NetworkAdapter class

    - by Mladen Prajdic
    WMI is Windows Management Instrumentation infrastructure for managing data and machines. We can access it by using WQL (WMI querying language or SQL for WMI). One thing to remember from the WQL link is that it doesn't support ORDER BY. This means that when you do SELECT * FROM wmiObject, the returned order of the objects is not guaranteed. It can return adapters in different order based on logged-in user, permissions of that user, etc… This is not documented anywhere that I've looked and is derived just from my observations. To get network adapters we have to query the Win32_NetworkAdapter class. This returns us all network adapters that windows detect, real and virtual ones, however it only supplies IPv4 data. I've tried various methods of combining properties that are common on all systems since Windows XP. The first thing to do to remove all virtual adapters (like tunneling, WAN miniports, etc…) created by Microsoft. We do this by adding WHERE Manufacturer!='Microsoft' to our WMI query. This greatly narrows the number of adapters we have to work with. Just on my machine it went from 20 adapters to 5. What was left were one real physical Realtek LAN adapter, 2 virtual adapters installed by VMware and 2 virtual adapters installed by VirtualBox. If you read the Win32_NetworkAdapter help page you'd notice that there's an AdapterType that enumerates various adapter types like LAN or Wireless and AdapterTypeID that gives you the same information as AdapterType only in integer form. The dirty little secret is that these 2 properties don't work. They are both hardcoded, AdapterTypeID to "0" and AdapterType to "Ethernet 802.3". The only exceptions I've seen so far are adapters that have no values at all for the two properties, "RAS Async Adapter" that has values of AdapterType = "Wide Area Network" and AdapterTypeID = "3" and various tunneling adapters that have values of AdapterType = "Tunnel" and AdapterTypeID = "15". In the help docs there isn't even a value for 15. So this property was of no help. Next property to give hope is NetConnectionId. This is the name of the network connection as it appears in the Control Panel -> Network Connections. Problem is this value is also localized into various languages and can have different names for different connection. So both of these properties don't help and we haven't even started talking about eliminating virtual adapters. Same as the previous one this property was also of no help. Next two properties I checked were ConfigManagerErrorCode and NetConnectionStatus in hopes of finding disabled and disconnected adapters. If an adapter is enabled but disconnected the ConfigManagerErrorCode = 0 with different NetConnectionStatus. If the adapter is disabled it reports ConfigManagerErrorCode = 22. This looked like a win by using (ConfigManagerErrorCode=0 or ConfigManagerErrorCode=22) in our condition. This way we get enabled (connected and disconnected adapters). Problem with all of the above properties is that none of them filter out the virtual adapters installed by virtualization software like VMware and VirtualBox. The last property to give hope is PNPDeviceID. There's an interesting observation about physical and virtual adapters with this property. Every virtual adapter PNPDeviceID starts with "ROOT\". Even VMware and VirtualBox ones. There were some really, really old physical adapters that had PNPDeviceID starting with "ROOT\" but those were in pre win XP era AFAIK. Since my minimum system to check was Windows XP SP2 I didn't have to worry about those. The only virtual adapter I've seen to not have PNPDeviceID start with "ROOT\" is the RAS Async Adapter for Wide Area Network. But because it is made by Microsoft we've eliminated it with the first condition for the manufacturer. Using the PNPDeviceID has so far proven to be really effective and I've tested it on over 20 different computers of various configurations from Windows XP laptops with wireless and bluetooth cards to virtualized Windows 2008 R2 servers. So far it always worked as expected. I will appreciate you letting me know if you find a configuration where it doesn't work. Let's see some C# code how to do this: ManagementObjectSearcher mos = null;// WHERE Manufacturer!='Microsoft' removes all of the // Microsoft provided virtual adapters like tunneling, miniports, and Wide Area Network adapters.mos = new ManagementObjectSearcher(@"SELECT * FROM Win32_NetworkAdapter WHERE Manufacturer != 'Microsoft'");// Trying the ConfigManagerErrorCode and NetConnectionStatus variations // proved to still not be enough and it returns adapters installed by // the virtualization software like VMWare and VirtualBox// ConfigManagerErrorCode = 0 -> Device is working properly. This covers enabled and/or disconnected devices// ConfigManagerErrorCode = 22 AND NetConnectionStatus = 0 -> Device is disabled and Disconnected. // Some virtual devices report ConfigManagerErrorCode = 22 (disabled) and some other NetConnectionStatus than 0mos = new ManagementObjectSearcher(@"SELECT * FROM Win32_NetworkAdapter WHERE Manufacturer != 'Microsoft' AND (ConfigManagerErrorCode = 0 OR (ConfigManagerErrorCode = 22 AND NetConnectionStatus = 0))");// Final solution with filtering on the Manufacturer and PNPDeviceID not starting with "ROOT\"// Physical devices have PNPDeviceID starting with "PCI\" or something else besides "ROOT\"mos = new ManagementObjectSearcher(@"SELECT * FROM Win32_NetworkAdapter WHERE Manufacturer != 'Microsoft' AND NOT PNPDeviceID LIKE 'ROOT\\%'");// Get the physical adapters and sort them by their index. // This is needed because they're not sorted by defaultIList<ManagementObject> managementObjectList = mos.Get() .Cast<ManagementObject>() .OrderBy(p => Convert.ToUInt32(p.Properties["Index"].Value)) .ToList();// Let's just show all the properties for all physical adapters.foreach (ManagementObject mo in managementObjectList){ foreach (PropertyData pd in mo.Properties) Console.WriteLine(pd.Name + ": " + (pd.Value ?? "N/A"));}   That's it. Hope this helps you in some way.

    Read the article

  • Recreating OMS instances in a HA environment when instances on all nodes are lost

    - by rnigam
    Oracle highly recommends deploying EM in a HA environment. The best practices for HA deployments, backup and housekeeping of your Enterprise Manager environment are documented in the Oracle Enterprise Manager Advanced Configuration Guide. It is imperative that there is a good disaster recovery plan in place for your EM deployment. In this post I want to talk about a customer who failed to do the correct planning and housekeeping for EM and landed in a situation where we the all the OMSes were nearly blown away had we not jumped to help. We recently hit an issue at a customer site where we had a two node OMS setup of the Enterprise Manager and a RAC Database being used as the EM repository. An accidental delete of the OMS oracle home left us with a single node deployment. While we were trying to figure out a possible path to recover the first node, the second node was rebooted under a maintenance window. What followed was a complete site outage as the Admin and managed servers would not start on either of the nodes. In my situation there were - No backups of the Oracle Homes from any node - No OMS Configuration snapshots (created using the “emctl exportconfig oms” command) and the instance home was completely lost on node 1 which also had the Admin Server  We did however have: - A copy of the emkey.ora that I found under the OMS_ORACLE_HOME/ of the second node (NOTE: it is a bad practice to have your emkey present under the OMS Oracle home directory on the same server as the OMS. The backup of the emkey should be maintained on some other server. In this case however it was a savior in my situation since there were no backups - The oms oracle home on the second node but missing a number of files and had a number of changes done to the files in the home. There were a number of attempts to start the server by modifying various files based on the Weblogic server logs to have atleast node up and running but all of them failed. Here is how you can recover from this scenario: Follow these steps: STEP 1: Check status of emkey.ora Check whether the emkey exists is present in the EM repository or not. Run the following command: $OMS_ORACLE_HOME/bin/emctl status emkey If the output is something like this below then you are good to go and the key is present in the repository ./emctl status emkey Oracle Enterprise Manager 11g Release 1 Grid Control Copyright (c) 1996, 2010 Oracle Corporation. All rights reserved. Enter Enterprise Manager Root (SYSMAN) Password : The EMKey is configured properly. Here are the messages that you might see as the emctl status emkey output depending upon whether the EM Admin Server is up and if the key is configured properly: Case1:  AdminServer is up, emkey is proper in CredStore & not in repos. This is same as the output of the command shown above:The EMKey is configured properly Case 2: AdminServer is up, emkey is proper in CredStore & exists in repos:The EMKey is configured properly, but is not secure. Secure the EMKey by running "emctl config emkey -remove_from_repos".Case 3: AdminServer is down or emkey is corrupted in CredStore) & (emkey exists in repos): The EMKey exists in the Management Repository, but is not configured properly or is corrupted in the credential store.Configure the EMKey by running "emctl config emkey -copy_to_credstore".Case 4: (AdminServer is down or emkey is corrupted in CredStore) & (emkey does not exist in repos): The EMKey is not configured properly or is corrupted in the credential store and does not exist in the Management Repository. To correct the problem:1) Get the backed up emkey.ora file.2) Configure the emkey by running "emctl config emkey -copy_to_credstore_from_file". If not the key was not secured properly, we will have to be put in the repository before proceeding. Look at the next step 2 for doing this There may be cases (like mine) where running emctl may give errors like the following: $OMS_ORACLE_HOME/bin/emctl status emkey Exception in thread “Main Thread” java.lang.NoClassDefFoundError: oracle/security/pki/OracleWallet At oracle.sysman.emctl.config.oms.EMKeyCmds.main (EMKeyCmds.java:658) Just move to the next step to put the key back in the repository STEP 2: Put emkey.ora back in the repository Skip this step if your emkey.ora is present in the repository. If not, you need to put the key back in the repository See if you can run the following command (with sample output): $OMS_ORACLE_HOME/bin/emctl config emkey –copy_to_repos Oracle Enterprise Manager 11g Release 1 Grid Control Copyright (c) 1996, 2010 Oracle Corporation. All rights reserved. The EMKey has been copied to the Management Repository. This operation will cause the EMKey to become unsecure. After the required operation has been completed, secure the EMKey by running "emctl config emkey -remove_from_repos". Typically the key is present under $OMS_ORACLE_HOME/sysman/config directory before being removed after the install as a best practice. If you hit any errors while running emctl commands like the one mentioned in step 1, jump to step 3 and we will take care of the emkey.ora in Step 5 STEP 3: Get the port information Check for the existing port information in the emd.properties file under EM_INSTANCE_DIRECTORY (typically gc_inst directory right above the Middleware home where you have deployed em. For eg. /u01/app/oracle/product/gc_inst in case your oms home is /u01/app/oracle/product/Middleware/oms11g) In my case I got the information from the emgc.properties present in the gc_inst on the second node. If you can run emctl you may want to try the following command as well $OMS_ORACLE_HOME/bin/emctl status oms –details Note this information as this will be used in the next step STEP 4: Perform cleanup on Node 1 Note the oracle home of the Weblogic and OMS, get the list of applied patches in the homes (using opatch lsinventory command), take a backup copy of the home just in case we need it and then de-install/remove oracle homes, update inventory and cleanup processes on the first node STEP 5: Perform Software Only Installation of OMS on Node 1 Perform Weblogic 10.3.2 installation exactly under the same location as present in the earlier installation. Perform software only installation of the OMS using the following command. This will not run any configuration assistants and bypass all user interface validations runInstaller –noconfig -validationaswarnings Select the “Additional OMS” option while performing the installation. Provide the same path for OMS and Instance directories like the previous installation Use the port information collected in Step 3 while performing the installation. Once the installation is complete run the allroot.sh script to complete the binary deployment STEP 6: Apply one-off patches At this point you can apply any patches to the OMS Oracle Home previously. You only need to run opatch to install the patch in the home and not required to run the SQLs STEP 7: Copy EM key This step is only required if you were not able to use emctl command to put the emkey back into the EM repository in STEP 2 Copy the emkey.ora file of the old installation you have under $OMS_ORACLE_HOME/sysman/config directory of the newly installed OMS STEP 8: Configure Grid Control Domain Run the following command to configure the EM domain and OMS. Note that you need to use a different GC Domain name than what you used earlier. For example I have used GCDOMAIN11 as the new domain name when my previous domain name was GCDOMAIN $OMS_ORACLE_HOME/bin/omsca new –AS_USERNAME weblogic –EM_DOMAIN_NAME GCDOMAIN11 –NM_USER nodemanager -nostart This command as shown below will prompt for a number of inputs like Admin Server hostname, port, password, etc. Verify if the defaults shown are correct by pressing enter or provide a new value STEP 9: Run Add-ON Configuration Assistant After this step run the following add-on configuration assistant. This was used in my case to configure the virtualization add-on $OMS_ORACLE_HOME/addonca -oui -omsonly -name vt -install gc STEP 10: Start the OMS Now start the OMS using $OMS_ORACLE_HOME/bin/emctl start oms In a multi-node setup like mine you would either have a software load balancer or DNS round robin (using a virtual host name that resolves to one of multiple OMS hostnames) being used for load balancing. Secure the OMS against the SLB or DNS virtual hostname using the following $ OMS_HOME/bin/emctl secure oms -host slb.example.com -secure_port 1159 -slb_port 1159 -slb_console_port 443 STEP 11: Configure the Agent From the $AGENT_ORACLE_HOME/bin run the ./agentca –f At this point you should have your OMS on node 1 fully re-covered. Clean up node 2 and use the normal Additional OMS installation process documented in the official installation guide to add the additional OMS on node 2 Summary It took us nearly a little over two days to completely recover the environment with some other non-EM related issues that hit us along the way as well. In the end a situation like this could have been completely avoided had the proper housekeeping and backup of the Enterprise Manager Deployment been done in the first place. This is going to a topic that we cover in the next post. In the meantime please do refer to the Oracle Enterprise Manager Advanced Configuration Guide for planning your EM installation, backup and housekeeping procedures. This can be found here: http://download.oracle.com/docs/cd/E11857_01/index.htm Thanks This post would not have been possible without Raj Aggarwal, Prasad Chebrolu and Ravikumar Basa who helped to recover the environment and provided all the support we needed

    Read the article

  • This update does not come from a source that supports changelogs

    - by blade19899
    When I get an update via update-manager for a software like blender/vlc, I like to see what has been fixed/changed. I added the ppa for blender/vlc (this only applies to the software I added a ppa for) sudo add-apt-repository ppa:cheleb/blender-svn sudo apt-get update sudo apt-get install blender And vlc like this. sudo add-apt-repository ppa:videolan/stable-daily sudo apt-get update sudo apt-get install vlc And when i run update-manager, or update manager pop-ups I see that vlc/blender have updates but, I can't see what has been changed/fixed this is the message I get, the screenshot below is for mupen but it's the same thing. (I updated vlc and blender, didn't wanna wait for the next update) This update does not come from a source that supports changelogs. (by the way I have a dutch Ubuntu, so the above text i Google translated it!) It only shows which version you have and to which version you be upgrading to. So my question is, how do I get the change-log tab of update-manager working. if it's even possible?

    Read the article

  • Realtek RTL8111/8168B wired network doesn't work anymore

    - by Radar4002
    This sounds like it's a common problem upgrading 11.04, but I am having trouble finding a common solution, and one that will work for me. I just applied updates via the update manager and now my wired network connection is down. I know Ubuntu network settings is the issue, because I have a dual-boot with Win 7 and my network/internet is fine on Win 7. I don't know too much about networking, so what can I do to trouble shoot this issue? I can choose an older grub version, 2.6.38-8 instead of 2.6.38-11 and this does not resolve the issue. Here is my lspci result: 00:00.0 Host bridge: ATI Technologies Inc RD890 Northbridge only single slot PCI-e GFX Hydra part (rev 02) 00:02.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (PCI express gpp port B) 00:04.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (PCI express gpp port D) 00:05.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (PCI express gpp port E) 00:06.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (PCI express gpp port F) 00:07.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (PCI express gpp port G) 00:09.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (PCI express gpp port H) 00:0a.0 PCI bridge: ATI Technologies Inc RD890 PCI to PCI bridge (external gfx1 port A) 00:11.0 SATA controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 SATA Controller [IDE mode] (rev 40) 00:12.0 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB OHCI0 Controller 00:12.2 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB EHCI Controller 00:13.0 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB OHCI0 Controller 00:13.2 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB EHCI Controller 00:14.0 SMBus: ATI Technologies Inc SBx00 SMBus Controller (rev 41) 00:14.1 IDE interface: ATI Technologies Inc SB7x0/SB8x0/SB9x0 IDE Controller (rev 40) 00:14.2 Audio device: ATI Technologies Inc SBx00 Azalia (Intel HDA) (rev 40) 00:14.3 ISA bridge: ATI Technologies Inc SB7x0/SB8x0/SB9x0 LPC host controller (rev 40) 00:14.4 PCI bridge: ATI Technologies Inc SBx00 PCI to PCI Bridge (rev 40) 00:14.5 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB OHCI2 Controller 00:15.0 PCI bridge: ATI Technologies Inc Device 43a0 00:16.0 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB OHCI0 Controller 00:16.2 USB Controller: ATI Technologies Inc SB7x0/SB8x0/SB9x0 USB EHCI Controller 00:18.0 Host bridge: Advanced Micro Devices [AMD] Family 10h Processor HyperTransport Configuration 00:18.1 Host bridge: Advanced Micro Devices [AMD] Family 10h Processor Address Map 00:18.2 Host bridge: Advanced Micro Devices [AMD] Family 10h Processor DRAM Controller 00:18.3 Host bridge: Advanced Micro Devices [AMD] Family 10h Processor Miscellaneous Control 00:18.4 Host bridge: Advanced Micro Devices [AMD] Family 10h Processor Link Control 01:00.0 VGA compatible controller: ATI Technologies Inc Juniper [Radeon HD 5700 Series] 01:00.1 Audio device: ATI Technologies Inc Juniper HDMI Audio [Radeon HD 5700 Series] 02:00.0 USB Controller: NEC Corporation uPD720200 USB 3.0 Host Controller (rev 03) 05:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 03) 06:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 03) 07:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 07:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 08:0e.0 FireWire (IEEE 1394): Texas Instruments TSB43AB23 IEEE-1394a-2000 Controller (PHY/Link) 09:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 09:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) Here is my sudo lshw -class network: *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:05:00.0 logical name: eth0 version: 03 serial: 6c:f0:49:e7:72:e8 size: 10Mbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list rom ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=half latency=0 link=no multicast=yes port=MII speed=10Mbit/s resources: irq:40 ioport:9e00(size=256) memory:fceff000-fcefffff memory:fcef8000-fcefbfff memory:fce00000-fce1ffff *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:06:00.0 logical name: eth1 version: 03 serial: 6c:f0:49:e7:72:ea size: 10Mbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list rom ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=half latency=0 link=no multicast=yes port=MII speed=10Mbit/s resources: irq:47 ioport:8e00(size=256) memory:fddff000-fddfffff memory:fddf8000-fddfbfff memory:fdd00000-fdd1ffff

    Read the article

  • Oracle Social Network Developer Challenge: Fishbowl Solutions

    - by Kellsey Ruppel
    Originally posted by Jake Kuramoto on The Apps Lab blog. Today, I give you the final entry in the Oracle Social Network Developer Challenge, held last week during OpenWorld. This one comes from Friend of the ‘Lab and Fishbowl Solutions (@fishbowle20) hacker, John Sim (@jrsim_uix), whom you might remember from his XBox Kinect demo at COLLABORATE 12 (presentation slides and abstract) hacks and other exploits with WebCenter. We put this challenge together specifically for developers like John, who like to experiment with new tools and push the envelope of what’s possible and build cool things, and as you can see from his entry John did just that, mashing together Google Maps and Oracle Social Network into a mobile app built with PhoneGap that uses the device’s camera and GPS to keep teams on the move in touch. He calls it a Mobile GeoTagging Solution, but I think Avengers Assemble! would have equally descriptive, given that was obviously his inspiration. Here’s his description of the mobile app: My proposed solution was to design and simplify GeoLocation mapping, and automate updates for users and teams on the move; who don’t have access to a laptop or want to take their ipads out – but allow them to make quick updates to OSN and upload photos taken from their mobile device – there and then. As part of this; the plan was to include a rules engine that could be configured by the user to allow the device to automatically update and post messages when they arrived at a set location(s). Inspiration for this came from on{x} – automate your life. Unfortunately, John didn’t make it to the conference to show off his hard work in person, but luckily, he had a colleague from Fishbowl and a video to showcase his work.    Here are some shots of John’s mobile app for your viewing pleasure: John’s thinking is sound. Geolocation is usually relegated to consumer use cases, thanks to services like foursquare, but distributed teams working on projects out in the world definitely need a way to stay in contact. Consider a construction job. Different contractors all converge on a single location, and time is money. Rather than calling or texting each other and risking a distracted driving accident, an app like John’s allows everyone on the job to see exactly where the other contractors are. Using his GPS rules, they could easily be notified about how close each is to the site, definitely useful when you have a flooring contractor sitting idle, waiting for an electrician to finish the wiring. The best part is that the project manager or general contractor could stay updated on all the action (or inaction) using Oracle Social Network, either sitting at a desk using the browser app or desktop client or on the go, using one of the native mobile apps built for Oracle Social Network. I can see this being used by insurance adjusters too, and really any team that, erm, assembles at a given spot. Of course, it’s also useful for meeting at the pub after the day’s work is done. Beyond people, this solution could also be implemented for physical objects that are in route to a destination. Say you’re a customer waiting on rail shipment or a package delivery. You could track your valuable’s whereabouts easily as they report their progress via checkins. If they deviated from the GPS rules, you’d be notified. You might even be able to get a picture into Oracle Social Network with some light hacking. Thanks to John and his colleagues at Fishbowl for participating in our challenge. We hope everyone had a good experience. Make sure to check out John’s blog post on his work and the experience using Oracle Social Network. Although this is the final, official entry we had, tomorrow, I’ll show you the work of someone who finished code, but wasn’t able to make the judging event. Stay tuned.

    Read the article

  • Can't connect to Apple Time Capsule in home network using Home Plugs from Win 7 Machine

    - by Eugene
    I have the following home network setup with subnet 255.255.255.0 but recently moved my time capsule to a different location when I added a third Home Plug and can no longer ping or map a network drive to it from the Windows 7 Machine. However using Airport Utility on the Windows 7 machine I can manually configure the Time Capsule. Using a Macbook on WIFI Network 1 or 2 - I can backup to the time capsule, so its accessible via both the router wifi network and the time capsule wifi network. The Time Capsule is set to BRIDGE function - ie no NAT or DHCP server enabled. Any bright sparks out there that can help diagnose the problem? Router (192.168.1.254) WIFI Network 1 | | |---- Home Plug one |---- Home Plug Two | |---- Computer A Windows 7 (192.168.1.160) | |---- Printer (192.168.1.69) |---- Home Plug Three | |---- Apple Time Capsule (192.168.1.150) WIFI Network 2 |---- Smart TV (192.168.1.70) | |---- Apple TV (192.168.1.4)

    Read the article

  • MSI netbook refuses to connect to home wireless network with Windows XP

    - by sa125
    I'm trying to connect my girlfriend's MSI netbook to the wireless network in my house, and failing repeatedly. It's not a hardware issue, b/c it connects to other networks successfully, and, it's not a network issue, because I have another mac and linux laptops that have no problem detecting and connecting to the same network. When I open windows' network connections box, I can see the network available, and when I try to connect to it (using a password), I get a "network no longer in range.." error (the router is 2 ft away). This has been the case for the past 6 months, and I'm about to give up. I've reset the router, erased all saved network preferences and pretty much all I could think of short of re-installing XP. Any idea what else could be done? thanks.

    Read the article

  • msi netbook refuses to connect to home wireless network (windows xp)

    - by sa125
    Hi - I'm trying to connect my girlfriend's MSI netbook to the wireless network in my house, and failing repeatedly. It's not a hardware issue, b/c it connects to other networks successfully, and, it's not a network issue, because I have another mac and linux laptops that have no problem detecting and connecting to the same network. When I open windows' network connections box, I can see the network available, and when I try to connect to it (using a password), I get a "network no longer in range.." error (the router is 2 ft away). This has been the case for the past 6 months, and I'm about to give up. I've reset the router, erased all saved network preferences and pretty much all I could think of short of re-installing XP. Any idea what else could be done? thanks.

    Read the article

  • Running an executable on network share with CustomAction with wix?

    - by martin
    Hello, i have created a msi-package which compresses some xml-files to a zip-file during installation. I have created a CustomAction for this purposes: <CustomAction Id="CompressMy" BinaryKey="zipEXE" ExeCommand="a -tzip &quot;[TEMPLATE_DIR]my.zip&quot; &quot;[TempSourceFolder]data.xml&quot;" Return="check" HideTarget="no" Impersonate="no" Execute="deferred" /> The installation works fine, if i try to install to a local drive, but recently a customer wanted to install [TEMPLATE_DIR] to a network drive on Windows Vista. The CustomAction fails, because of the elevated install-user hasn't mapped the network drive, even if the installer-calling user has mapped the drive. This happens also, if I try to install to an unc-path. I use 7zip for compressing. I have added it to my msi-package. I have tried to set Impersonate="yes", but then the Installations fails, if my TEMPLATE_DIR is f.e. the ProgramData-dir. Do you have any idea what i can do? I thinked about checking if TEMPLATE_DIR is a network path, but I didn't know how i can check this. Or do you have any other Ideas how I can provide a local and a network installation while using this custom action. Would be great if there are any advices, greetings, Martin

    Read the article

  • Cisco Call Manager adding 7945's

    - by Will
    Hello we currently have a call manager settup (older we are working on upgrading it) but for now we are looking to add 7945 IP phones. We currently have 7960's all over the place, but we can't get these new anymore. Here is the info about our call manager ace.dll 5.2.5.0 CCM4.1(3) aced.dll CCM4.1(3) AdministrativeReportingTool.exe 4.1(0.45) 4.1(3)sr4d Apache Tomcat 4.1 CCM4.1(3) ASTIsapi.dll 3.3.2.0 4.1(3)sr4d AudioTranslator.exe 4.0.0.3 CCM4.1(3) Aupair.exe 4.1.3.10472 4.1(3)sr4d AupairChangeNotify.dll 4.1.0.11 CCM4.1(3) AuthFilt.dll 4.0.0.0 4.1(3)sr4d AVVIDCustomerDirectoryConfigurationPlugin.exe 4.1.0.17(0) CCM4.1(3) bootp.exe 2.0.2.2 CCM4.1(3) BulkAdministrationTool.exe 5.1(4c) 4.1(3)sr4d CallBackService.exe 3.3.2.3 4.1(3)sr4d ccm.exe 4.1.3.17472 4.1(3)sr4d CcmPerfMon.dll 4.1(3)sr4d CCNTEST.EXE CCM4.1(3) cdpintf.dll 4.0.0.0 CCM4.1(3) Cisco CallManager 4.1(3)sr4d 4.1(3)sr4d One of the admins recommenced downloading a device pack, which we did. However when we ran it on the call manager server it gave the error "unable to read script" Any recommendations on how to get these phones working with our Call Manager? Thank you.

    Read the article

  • Can a Linux system crash cause network issues?

    - by Supratik
    I have a Ubuntu box in my network which crashed, all the system connected to the switch in which the Ubuntu system was connected started giving problem. I removed that system from the network, since that was the last change I made in my network and everything was fine. So, to confirm this I again connected the system back to the network and the same network outage happened. When I checked the links it was fine. When I rebooted the problematic system and again connected back to the network switch everything started working. I think possibly the crash of the Ubuntu system could have caused this outage. Is there any possibility that a kernel crash can cause network issues?

    Read the article

  • How to set up VLAN network

    - by Paddington
    I'm changing my network from having every device on flat network to using VLans. My problem is that we already have a lot of devices on this network(192.168.20.0/24). From theory, I read that each Vlan has to be a different subnet and then I need to configure virtual interfaces on my Cisco router to cater for inter vlan routing. 1) How can I segment this network with minimum down time on the devices already on the network? 2) Can I just create Vlans and leave all these Vlans in the same layer 3 network so that they can go out of the network (I am not too concerned about inter-Vlan routing) or I have to create subnets which means reconfiguring the existing devices (something I do not want).

    Read the article

  • How to control manager class in Blackberry

    - by Keng
    Dear All, I have a problem when creating a UI on Blackberry. First, i try to create a ChatLayoutManager class extended from Manager class. My layout has three component: topfield, mainfield and bottom field. public class ChatLayoutManager extends Manager { private Field bottomField; private Field mainField; private Field titleField; public ChatLayoutManager(long style) { super(style); } protected void sublayout(int width, int height) { setExtent(width, height); int y = 0; if (bottomField != null) { layoutChild(bottomField, width, height); // This goes at the bottom of the screen setPositionChild(bottomField, 0, height-bottomField.getHeight()); height -= bottomField.getHeight(); } if (titleField != null) { layoutChild(titleField, width, height); // This goes at the top of the screen setPositionChild(titleField, 0, 0); height -= titleField.getHeight(); y += titleField.getHeight(); } if (mainField != null) { layoutChild(mainField, width, height); // This goes just below the title field (if any) setPositionChild(mainField, 0, y); } } public void setMainField(Field f) { mainField = f; add(f); } public void setBottomField(Field f) { bottomField = f; add(f); } public void setTitleField(Field f) { titleField = f; add(f); } Then i create another field (ChatField) extended from manager to add to mainfield in the ChatLayoutManager class which i have created above. public class ChatField extends Manager{ private Field _contentField[]; protected ChatField(){ super(Manager.HORIZONTAL_SCROLL | Manager.VERTICAL_SCROLL); } // TODO Auto-generated constructor stub} protected synchronized void sublayout(int width, int height) { // TODO Auto-generated method stub setExtent(width, height); int x = 0; int y = 0; if(_contentField.length > 0){ for(int i = 0 ;i<_contentField.length; i++){ //if(getManager() == this){ this.layoutChild(_contentField[i], _contentField[i].getWidth(), _contentField[i].getHeight()); this.setPositionChild(_contentField[i], x, y); if(_contentField[i++]!= null){ if ((_contentField[i].getWidth() + _contentField[i].getWidth()) >= width){ x = 0; y += _contentField[i].getHeight(); } else{ x += _contentField[i].getWidth(); } } //} } } } public void setContentField(Field field[]){ _contentField = field; } } And now, when i create some fields(such as TextField, BitmapField ...) added to ChatField, the program has an error "Field is not a child of this manager". The reason is when the framework invokes the sublayout function of the ChatField class , when sublayout starts calling layoutChild function the manager of field is not ChatField but ChatlayoutManager. I've experience hard time trying to resolve this problem, still I have no solution. Anybody can give me some suggestions? I really appreciate.

    Read the article

  • Network Solutions Gold VIP Program

    - by GGBlogger
    Today I received an email advising me “Congratulations! You have been selected for the Network Solutions Gold VIP Program” Now I get a bunch of messages from Network Solutions because a long time ago I chose them as my registrar. I usually just save these to my Outlook Network Solutions folder and move on. This time my wife was in the room and I chuckled and said something about “Network Solutions has made me a Gold VIP member.” She said “So what does that mean?” Prompted by that I scrolled down the page to look at my “perks". Let’s see – Special pricing, 1 year free Web Forwarding, 1 hour of free support… etc etc until I hit “Enrollment in SafeRenew* SafeRenew* simplifies your renewal process. It protects your domain name registrations and corresponding services in the event you forget or are unable to renew on time. I’m thinking “Now ain’t that neat” I don’t use auto renew anyway and never have. Then I continued reading: Beginning June 24th, 2012 your domains* (that’s 10 days away) will automatically renew. To ensure continuation of service, please be certain you have a valid credit card on file. If you do not wish for your services to be automatically renewed, please click here to log into account manager and opt out of the SafeRenew™ service. Whoa Network Solutions is going to start spending my money without so much as a by your leave sir!!! I don’t bloody think so and how truly magnanimous of them I can “click here” to opt out of what I didn’t opt in for. Talk about furious! I still am. Now the kicker is: if my wife hadn’t been curious and if I’d had a working credit card on file I wouldn’t have know this until one of my unwanted domain names auto renewed. Of course I was told “Oh – we’d have refunded your money” to which I say bull. In my view Networks Solutions is guilty of a crime of some sort. They DO NOT have a right to spend my money without asking!!!!! So watch out folks.

    Read the article

  • What are your thoughts on a possible Developer's Television Network?

    - by Anthony Forloney
    I am a huge fan of informational television shows. Anytime I can learn something new by watching a television show, I am all for it. I wondered about how the community felt about a Developer Network for developers. What are the added advantages and disadvantages of having such a TV network? As an added bonus, what type of television shows should be aired on the network? Make up some fun and interesting television shows and elaborate. Also, for each television show, who could be a potential host? Jon Skeet for a C# television show? Phil Haack for an ASP.NET television show? I am looking forward to some interesting responses.

    Read the article

  • Why do I get HTTP Code 414 on one network but not another?

    - by Stephen Darlington
    I have an otherwise working iPhone program. A recent change means that it generates some very long URLs (over 4000 characters sometimes) which I know isn't a great idea and I know how to fix -- that's not what I'm asking here. The curious thing is that when I make the connection using a 3G network (Vodafone UK) I get this HTTP "414 Request-URI Too Long" error but when I connect using my local WiFi connection it works just fine. Why would I get different results using different types of network? Could they be routing requests to different servers depending on where the connection originates? Or is there something else at stake here? The corollary questions relate to how common this is. Is it likely to happen whenever I use a cell network or just some networks?

    Read the article

  • Adding A Custom Dropdown in RCDC for Forefront Identity Manager 2010

    - by Daniel Lackey
    My latest exploration has been FIM 2010 for Identity Management. The following is a post of how to add a custom dropdown for the FIM Portal. I have decided to document this as I cannot find documentation on how to do this anywhere else. I hope that it finds useful to others.   For starters, this was to me not an easy task to figure out. I really would like to know why it is so cumbersome to do something that seems like a lot of people would need to do, but that’s for another day J   The dropdown I wanted to add was for ‘Account Status’ which would display if the account is ‘Enabled’ or ‘Disabled’ in the data source Active Directory. This option would also allow helpdesk users or admins to administer the userAccountControl attribute in AD from the FIM Portal interface.   The first thing I had to do was create the attribute itself. This is done by going to Administration à Schema Management from the FIM 2010 portal. Once here, you click on All Attributes. What is listed here are all attributes and their associated Resource Types in FIM. To create the ‘AccountStatus’ attribute, click on New. As shown below, enter ‘AccountStatus’ with no spaces for the System Name and ‘Account Status’ for the Display Name. The Data Type is going to be ‘Indexed String’. Click Next.           Leave everything on the Localization tab default and click Next.   On the Validation tab as shown below, we will enter the regex expression ^(Enabled|Disabled)?$ with our two desired string values ‘Enabled’ and ‘Disabled’. Click on Finish and then and Submit to complete adding the attribute.       The next step involves associating the attribute with a resource type. This is called ‘Binding’ the attribute. From the Schema Management page, click on All Bindings. From the page that comes up, click on New. As shown below, enter ‘User’ for the Resource Type and ‘Account Status’ for the Attribute Type. This is essentially binding the Account Status attribute to the ‘User’ Resource Type. Click Next.    On the ‘Attribute Override’ tab, type in ‘Account Status’ for the Display Name field. Click Next.   On the ‘Localization’ tab, click Next.   On the ‘Validation’ tab, enter the regex expression ^(Enabled|Disabled)?$ we entered previously for the attribute. Click Finish and then Submit to complete.   Now that the Attribute and the Binding are complete, you have to give users permission to see the attribute on the User Edit page. Go to Administration à Management Policy Rules. Look for the rule named Administration: Administrators can read and update Users and click on it. Once it opens, click on the ‘Target Resources’ tab and look at the section named Resource Attributes. Type in at the end the ‘Account Status’ attribute and check it with the validator. Once done click on OK to save the changes.         Lastly, we need to add the actual dropdown control to the RCDC (Resource Control Display Configuration) for User Editing. Go to Administration à Resource Control Display Configuration. From here navigate until you find the RCDC named Configuration for User Editing RCDC and click on it. The following is what you will see:       First step is to export the Configuration Data file. Click on the Export configuration link and save the file to your desktop of other folder.   Find the file you just exported and open the file in your XML editor of choice. I use notepad but anything will work. Since we are adding a dropdown control, first find another control in the existing file that is already a dropdown in FIM. I used EmployeeType as my example. Copy the control from the beginning tag named <my:Control… to the ending tag </my:Control>. Now take what you copied and paste it in whatever location you desire within the form between two other controls. I chose to place the ‘Account Status’ field after the ‘Account Name’ field. After you paste the control you will need to modify so it looks like this:       Notice where you specify what attribute you are dealing with where it has AccountStatus in the XML. Once you are complete with modifying this, save the file and make sure it is a .xml file.   Now go back to the Configuration for User Editing screen and look at the section named ‘Configuration Data’. Click the ‘Browse’ button and find the XML file you just modified and choose it. Click OK on the bottom of the window and you are done!   Now when you click on a user’s name in the FIM Portal, you should see the newly added dropdown box as below:       Later I will post more about this drop down, specifically on how to automate actually ‘Disabling’ the account in the data source through the FIM Workflows and MAs.   <my:Control my:Name="AccountStatus" my:TypeName="UocDropDownList" my:Caption="{Binding Source=schema, Path=AccountStatus.DisplayName}" my:Description="{Binding Source=schema, Path=AccountStatus.Description}" my:RightsLevel="{Binding Source=rights, Path=AccountStatus}"> <my:Properties> <my:Property my:Name="ValuePath" my:Value="Value"/> <my:Property my:Name="CaptionPath" my:Value="Caption"/> <my:Property my:Name="HintPath" my:Value="Hint"/> <my:Property my:Name="ItemSource" my:Value="{Binding Source=schema, Path=AccountStatus.LocalizedAllowedValues}"/> <my:Property my:Name="SelectedValue" my:Value="{Binding Source=object, Path=AccountStatus, Mode=TwoWay}"/> </my:Properties> </my:Control>

    Read the article

  • Visual Studio 2010 Extension Manager (and the new VS 2010 PowerCommands Extension)

    This is the twenty-third in a series of blog posts Im doing on the VS 2010 and .NET 4 release. Todays blog post covers some of the extensibility improvements made in VS 2010 as well as a cool new "PowerCommands for Visual Studio 2010 extension that Microsoft just released (and which can be downloaded and used for free). [In addition to blogging, I am also now using Twitter for quick updates and to share links. Follow me at: twitter.com/scottgu] Extensibility in VS 2010 VS 2010...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Remote Desktop Connection - Connection Failed

    - by NLV
    Let me explain the problem. My system is connected to a network and 'was' having XP installed in it. Recently i formatted the system and installed windows server 2003 and added the machine to the network. Everything is working fine like mapping the network drives, pinging the machines etc. But i've the following problems. I'm not able to do a remote desktop connection to another system in the network. Some systems in the network is able to do a remote desktop to my machine. But not all. If i host any web service in my system i'm not able to connect it from any other machine in the network. I've already configured the Remote Desktop to accept connections. Any ideas? NLV

    Read the article