Search Results

Search found 1946 results on 78 pages for 'dim'.

Page 57/78 | < Previous Page | 53 54 55 56 57 58 59 60 61 62 63 64  | Next Page >

  • Windows 7 on 1st Gen Macbook Pro (Q4-2008), power management problems.

    - by typemismatch
    I have the first generation macbook pro, purchased Q4 2008. I've been trying to run Windows 7 and can get it all installed great with the BootCamp 3.1 64 bit drivers however ... power management isn't great. The screen and keyboard don't automatically dim - the laptop gets too hot. I noticed on some newer macbook pros that windows 7 works perfectly and the above doesn't happen. Does anyone know if there really is a hardware issue with this 1st gen or is there some firmware update I can use to fix this? Thanks!

    Read the article

  • AD Stopping A script and Adding a Value to A User's Account Attribute

    - by Steven Maxon
    ‘This will launch the PPT in a GPO Dim ppt Set ppt = CreateObject("PowerPoint.Application") ppt.Visible = True ppt.Presentations.Open "C:\Scripts\Test.pptx" ‘This is the batch file at the end of the PPT that records the date, time, computer name and username echo "Logon Date:%date%,Logon Time:%time%,Computer Name:%computername%,User Name:%username%" \servertest\g$\Tracking\LOGON.TXT ‘This is what I need but can’t find: I need the script to check a value in the Active Directory user’s account in the Web page: attribute that would shut off the script if the user has already competed reading the presentation. Could be as simple as writing XXXX. I need the value XXXX written to the Active Directory user’s account in the Web page: attribute when they finish reading the presentation after they click on the bat file so the script will not run again when they log in. Thanks for any help.

    Read the article

  • How can I make a VB script execute every time Windows starts up?

    - by jon
    My goal is to copy INI.file each time Windows XP is started up or rebooted. The following VB script copies INI.file from a local directory to C:\INI_DIR. I tried to copy the VB script to C:\WINDOWS\system32\config\systemprofile\Start Menu\Programs\Startup, but it doesn't get activated. Is it not the right path? How can I make it execute on startup/reboot? The script: Dim currDir Const OverwriteExisting = True Set fso = CreateObject("Scripting.FileSystemObject") currDir = fso.GetParentFolderName(Wscript.ScriptFullName) Set objFSO = CreateObject("Scripting.FileSystemObject") objFSO.CopyFile currDir & "\INI.file" , "C:\INI_DIR" , OverwriteExisting ' Release the objFSO objects Set objFSO = Nothing ' Release the fso objects Set fso = Nothing

    Read the article

  • My MacBook Pro (2011) is dead

    - by Dave
    I connected my Sony digital camera with the MacBook and the screen turned black. I wonder why because the Sony camera was not on at the time and technically could not be accessed. So I thought it might be temporary and I turned on my camera. Well, it did not work, but my MacBook Pro has been dead since then. It will not turn on - when I hold the power button for five seconds, nothing happens. When I connect the charger cable, the green light is very dim and blinks a little (with about 20% illumination). I wonder what the problem is. I have to call Apple Care, but just so that I know, what could be wrong? Is my MacBook permanently dead? It might be under warranty but I am not sure.

    Read the article

  • Filling cells with sequential numbers in an Excel (2003) macro

    - by Fred Hamilton
    I need to fill an excel column with a sequential series, in this case from -500 to 1000. I've got a macro to do it, but it takes a lot of lines for something that seems like it should be a single function [something like FillRange(A2:A1502, -500, 1000, 1)]. But if that function exists, I can't find it. Is the following as simple and elegant as it gets? 'Draw X axis scale Cells(1, 1).Value = "mV" Cells(2, 1).Value = -500 Cells(3, 1).Value = -499 Cells(4, 1).Value = -498 Dim selection1 As Range, selection2 As Range Set selection1 = Sheet1.Range("A2:A4") Set selection2 = Sheet1.Range("A2:A1502") selection1.AutoFill Destination:=selection2

    Read the article

  • Do you know of any ways to effectively manage a triple screen setup brightness?

    - by nizm0
    I use a desktop with multiple monitors I have tried F.lux and it is a great app for changing the color from 3500k-6500k... but doesn't adjust screen brightness. (I recommend you try it) I've googled for hours trying to find an app that will work to let me easily manage screen brightness either by a "dim when idle" or a dynamically updating screen brightness based on the time of day. Windows 7 desktop doesn't seem to have options for me to adjust brightness on the system, and manually changing three separate monitors is too much of a chore? Anybody have some recommendations? Perhaps a way to script this, knowledge of how to use the supposed dynamic screen brightness functions that Windows was supposed to add in Windows 7?

    Read the article

  • Windows 7 on 1st Gen MacbookPro Unibody (Q4-2008) - power problems.

    - by typemismatch
    I have the first generation macbook pro, purchased Q4 2008. I've been trying to run Windows 7 and can get it all installed great with the BootCamp 3.1 64 bit drivers however ... power management isn't great. The screen and keyboard don't automatically dim - the laptop gets too hot. I noticed on some newer macbook pros that windows 7 works perfectly and the above doesn't happen. Does anyone know if there really is a hardware issue with this 1st gen or is there some firmware update I can use to fix this? Thanks!

    Read the article

  • How to limit my CPU power programmatically on Windows 7?

    - by Ivan
    Whenever I run a CPU-heavy activity (like compressing a big set of files into an archive for example) my CPU switches to its full throttle (maximum frequency) and shuts down of overheat in less than a minute. Instead, I would like it to keep slowed-down slightly to do the task a bit slower but be able to reach the finish. At the same time I don't want to dim my screen brightness or adjust anything else what standard Windows power-saving system does. So how do I actually set a cap to limit my CPU power? The CPU is Core 2 Duo T7250, the OS is Windows 7 32-bit, there seem to be no BIOS settings or jumpers available to configure the frequencies.

    Read the article

  • Setup dual screen with Catalyst Control Center on notebook so that nothing changes when closing lid (case) ?

    - by Tom
    I have setup a dualscreen setup for my notebook with an ATI video card (ATI mobility radeon hd 5470) using Catalyst Control Center. The monitor extends the desktop of the notebook's screen. This works great. I am running on windows 7 and have set it up to not do anything when I close my laptop's lid (case) other than dim the notebook's display. However, when I do close the lid (notebook's display), the second monitor suddenly changes and I believe it starts behaving as the primary monitor.. I do not want this to happen. So, how do I setup my dualscreen setup so that it won't set the secondary monitor as the primary one when I close my laptop's lid? UPDATE: this video shows exactly what my problem is: http://www.youtube.com/watch?v=Q1ygNHbqI2g

    Read the article

  • MS Excel find and replace macro

    - by william
    I have written a macro to remove special characters in a sheet based on ascii values but the problem with it is that it is replacing the cell content. For example p;j;h which should become p,j,h is becoming ,, (missing the data). Do I need to include any additional statements, or how else to adjust my code? sub specialcharecters() Dim i As Long For i = 32 To 43 Selection.Replace what:=Chr(i), replacement:=", ", LookAt:=xlPart, SearchOrder:= _ xlByRows, MatchCase:=False, SearchFormat:=False, ReplaceFormat:=False Next i Selection.Replace what:="~*", replacement:=", ", LookAt:=xlPart, SearchOrder:= _ xlByRows, MatchCase:=False, SearchFormat:=False, ReplaceFormat:=False For i = 45 To 47 Selection.Replace what:=Chr(i), replacement:=", ", LookAt:=xlPart, SearchOrder:= _ xlByRows, MatchCase:=False, SearchFormat:=False, ReplaceFormat:=False Next i For i = 58 To 64 Selection.Replace what:=Chr(i), replacement:=", ", LookAt:=xlPart, SearchOrder:= _ xlByRows, MatchCase:=False, SearchFormat:=False, ReplaceFormat:=False Next i For i = 123 To 125 Selection.Replace what:=Chr(i), replacement:=", ", LookAt:=xlPart, SearchOrder:= _ xlByRows, MatchCase:=False, SearchFormat:=False, ReplaceFormat:=False Next i Selection.Replace what:="~~", replacement:=", ", LookAt:=xlPart, SearchOrder:= _ xlByRows, MatchCase:=False, SearchFormat:=False, ReplaceFormat:=False END sub

    Read the article

  • Backlight dimming don't work

    - by Mathias
    My Packard Bell EasyNote TS11HR notebook does not have an option for dimming the display backlight. At night, my eyes begin to hurt because of the strong light from the screen. My laptop is 2-3 months old and I am sure it has worked before. When I click on the battery icon in the notification area, it says in my language (Danish): "the setting for light does possibly reduce the life of the battery". However, I cannot dim the backlight. I have tried downloading programs for dimming the screen but they only make the screen darker, instead of dimming the backlight. I have tried updating my drivers and looking in the BIOS for a setting. I also plan to use an Ubuntu LiveCD to try controlling it. As of now though, the backlight is locked at maximum. Any ideas?

    Read the article

  • Dual Monitors don't turn off/sleep when they should

    - by Mario
    Details: Dual 25" monitors connected to HP Envy via HDMI and display port via DVI adapter. Power scheme is set up in high performance (Dim Display: Never - Turn Off Display: 15 mins - Computer Sleep: Never) Screensaver is set up to kick in after 10 mins of idle (which happens) 5 minutes later, the screensaver stops. The "Monitor Going to Sleep" notice appears on screen and monitors go to sleep briefly. All is well thus far. Suddenly, the Windows 7 alert sound when a device is unplugged is heard. Monitors then turn back on. Screens are black. Only the mouse cursor is displayed. Backlighting is back on. This only started happening after I obtained and connected the second 25" monitor a few days ago. However, I had a 24" in its place before, and this wasn't happening. Why is this happening and how do I correct this behavior? Thanks in advance.

    Read the article

  • Can I move a copy of Windows 7 from one machine to another?

    - by Chopper3
    This is a pretty basic question sorry but I've looked in the 'related questions' and couldn't find an answer. When Windows 7 came out I bought a copy of Home Premium, the retail box with both 32 and 64 bit versions, to install via Boot Camp on my macbook. I've just got a retail (32 and 64 bit) copy of Windows 7 Ultimate that I'd like to install instead-of/over the Home Premium version and it struck me that I should, at least in principal be able to install the Home Premium version on my son's machine - is this the case and if so is there anything I should do first or once they're installed to let MS know I'm being a good guy about this? Sorry it's such a dim question but I'm a serverfault guy really and know very little about Windows. Thanks.

    Read the article

  • Windows XP occasionally hangs for 2-3 minutes as the splash screen fades in.

    - by marcusw
    This is a bit of a rare problem, I have not been able to debug or fix it or find anyone else with the issue. I hope someone here can help me out. Once in a while, I boot up Windows XP from the first partition of the first disk (using grub, the computer dual-boots ubuntu) and it hangs as the Windows XP splash image fades in, leaving the screen with a dim image of the splash screen. After 2-3 minutes, it continues to boot as normal, no error messages or strange behavior. I have noticed that this happens about 75% of the time when the last time the computer was shut down it was from Ubuntu, and maybe 5-10% of the time otherwise. I have looked at system logs as far as I was able, and did not find anything the miss. What is causing this and how can I fix it?

    Read the article

  • Hide/Unhide rows based on more than one cell value

    - by Mike
    Please help me I am using the following code to hide rows if cell values are 0: Private Sub Worksheet_Calculate() Dim LastRow As Long, c As Range Application.EnableEvents = False LastRow = Cells(Cells.Rows.Count, "I").End(xlUp).Row On Error Resume Next For Each c In Range("I9:I48") If c.Value = 0 Then c.EntireRow.Hidden = True ElseIf c.Value > 0 Then c.EntireRow.Hidden = False End If Next On Error GoTo 0 Application.EnableEvents = True End Sub It works perfectly, but I would like for the code to also check column K (the same range K9:K48) if both cells in a row are 0 then the row must be hidden. How can I change the code to do this?

    Read the article

  • jQuery DataTables server side processing and ASP.Net

    - by Chad
    I'm trying to use the server side functionality of the jQuery Datatables plugin with ASP.Net. The ajax request is returning valid JSON, but nothing is showing up in the table. I originally had problems with the data I was sending in the ajax request. I was getting a "Invalid JSON primative" error. I discovered that the data needs to be in a string instead of JSON serialized, as described in this post: http://encosia.com/2008/06/05/3-mistakes-to-avoid-when-using-jquery-with-aspnet-ajax/. I wasn't quite sure how to fix that, so I tried adding this in the ajax request: "data": "{'sEcho': '" + aoData.sEcho + "'}" If the aboves eventually works I'll add the other parameters later. Right now I'm just trying to get something to show up in my table. The returning JSON looks ok and validates, but the sEcho in the post is undefined, and I think thats why no data is being loaded into the table. So, what am I doing wrong? Am I even on the right track or am I being stupid? Does anyone ran into this before or have any suggestions? Here's my jQuery: $(document).ready(function() { $("#grid").dataTable({ "bJQueryUI": true, "sPaginationType": "full_numbers", "bServerSide":true, "sAjaxSource": "GridTest.asmx/ServerSideTest", "fnServerData": function(sSource, aoData, fnCallback) { $.ajax({ "type": "POST", "dataType": 'json', "contentType": "application/json; charset=utf-8", "url": sSource, "data": "{'sEcho': '" + aoData.sEcho + "'}", "success": fnCallback }); } }); }); HTML: <table id="grid"> <thead> <tr> <th>Last Name</th> <th>First Name</th> <th>UserID</th> </tr> </thead> <tbody> <tr> <td colspan="5" class="dataTables_empty">Loading data from server</td> </tr> </tbody> </table> Webmethod: <WebMethod()> _ Public Function ServerSideTest() As Data Dim list As New List(Of String) list.Add("testing") list.Add("chad") list.Add("testing") Dim container As New List(Of List(Of String)) container.Add(list) list = New List(Of String) list.Add("testing2") list.Add("chad") list.Add("testing") container.Add(list) HttpContext.Current.Response.ContentType = "application/json" Return New Data(HttpContext.Current.Request("sEcho"), 2, 2, container) End Function Public Class Data Private _iTotalRecords As Integer Private _iTotalDisplayRecords As Integer Private _sEcho As Integer Private _sColumns As String Private _aaData As List(Of List(Of String)) Public Property sEcho() As Integer Get Return _sEcho End Get Set(ByVal value As Integer) _sEcho = value End Set End Property Public Property iTotalRecords() As Integer Get Return _iTotalRecords End Get Set(ByVal value As Integer) _iTotalRecords = value End Set End Property Public Property iTotalDisplayRecords() As Integer Get Return _iTotalDisplayRecords End Get Set(ByVal value As Integer) _iTotalDisplayRecords = value End Set End Property Public Property aaData() As List(Of List(Of String)) Get Return _aaData End Get Set(ByVal value As List(Of List(Of String))) _aaData = value End Set End Property Public Sub New(ByVal sEcho As Integer, ByVal iTotalRecords As Integer, ByVal iTotalDisplayRecords As Integer, ByVal aaData As List(Of List(Of String))) If sEcho <> 0 Then Me.sEcho = sEcho Me.iTotalRecords = iTotalRecords Me.iTotalDisplayRecords = iTotalDisplayRecords Me.aaData = aaData End Sub Returned JSON: {"__type":"Data","sEcho":0,"iTotalRecords":2,"iTotalDisplayRecords":2,"aaData":[["testing","chad","testing"],["testing2","chad","testing"]]}

    Read the article

  • System.Reflection and InvokeMember, storing type, assembly, and object in a class

    - by Cyclone
    I have tested code to call a method inside of a compiled DLL, and it works. I created a class to store the object, type, and loaded assembly, but something is lost in translation because it is unable to find the member I wish to invoke. If I create a type, object, and assembly, and properly load everything into these and perform InvokeMember on the type, it works just fine. However, when I use the things inside of my class, it throws a MissingMemberException and does not invoke the member, obviously. What am I doing wrong? The member in question is a subroutine which takes one argument, a string. This is quite frustrating. Code being called: Dim MyLoadedAssembly As New LoadedAssembly() MyLoadedAssembly.MyAssembly = Assembly.LoadFrom("display.dll") MyLoadedAssembly.MyObject = MyLoadedAssembly.MyAssembly.CreateInstance("Display.UI.Window") MyLoadedAssembly.MyType = MyLoadedAssembly.MyAssembly.GetType("Display.UI.Window") Dim args() As Object = {"test"} MyLoadedAssembly.InvokeMember("Show", args) Private Class LoadedAssembly Public MyType As Type Public MyObject As Object Public MyAssembly As Assembly Public Function InvokeMember(ByVal name As String, ByVal args() As Object) Return MyType.InvokeMember(name, BindingFlags.Default Or BindingFlags.InvokeMethod Or BindingFlags.GetProperty Or BindingFlags.Instance, Nothing, MyObject, args) End Function End Class Code inside of display.dll: Namespace UI Public Class Window Private wind As New System.Windows.Forms.Form Public FullScreen As Boolean = False Public Overloads Sub Show(ByVal text As String) wind.Show() wind.Text = text End Sub Public Overloads Sub Show() wind.Show() End Sub End Class End Namespace The root namespace for display.dll is Display. Why is my code only working when not within this class? System.MissingMethodException was unhandled Message="Method 'Display.UI.Window.Show' not found." Source="mscorlib" StackTrace: at System.RuntimeType.InvokeMember(String name, BindingFlags bindingFlags, Binder binder, Object target, Object[] providedArgs, ParameterModifier[] modifiers, CultureInfo culture, String[] namedParams) at System.Type.InvokeMember(String name, BindingFlags invokeAttr, Binder binder, Object target, Object[] args) at IDE.IDE.LoadedAssembly.InvokeMember(String name, Object[] args) in C:\Documents and Settings\Davey\Desktop\RaptorScript\RaptorScript\RaptorScript\IDE.vb:line 69 at IDE.IDE.IDE_Load(Object sender, EventArgs e) in C:\Documents and Settings\Davey\Desktop\RaptorScript\RaptorScript\RaptorScript\IDE.vb:line 50 at System.EventHandler.Invoke(Object sender, EventArgs e) at System.Windows.Forms.Form.OnLoad(EventArgs e) at System.Windows.Forms.Form.OnCreateControl() at System.Windows.Forms.Control.CreateControl(Boolean fIgnoreVisible) at System.Windows.Forms.Control.CreateControl() at System.Windows.Forms.Control.WmShowWindow(Message& m) at System.Windows.Forms.Control.WndProc(Message& m) at System.Windows.Forms.ScrollableControl.WndProc(Message& m) at System.Windows.Forms.ContainerControl.WndProc(Message& m) at System.Windows.Forms.Form.WmShowWindow(Message& m) at System.Windows.Forms.Form.WndProc(Message& m) at System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m) at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m) at System.Windows.Forms.NativeWindow.DebuggableCallback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam) at System.Windows.Forms.SafeNativeMethods.ShowWindow(HandleRef hWnd, Int32 nCmdShow) at System.Windows.Forms.Control.SetVisibleCore(Boolean value) at System.Windows.Forms.Form.SetVisibleCore(Boolean value) at System.Windows.Forms.Control.set_Visible(Boolean value) at System.Windows.Forms.Application.ThreadContext.RunMessageLoopInner(Int32 reason, ApplicationContext context) at System.Windows.Forms.Application.ThreadContext.RunMessageLoop(Int32 reason, ApplicationContext context) at System.Windows.Forms.Application.Run(ApplicationContext context) at Microsoft.VisualBasic.ApplicationServices.WindowsFormsApplicationBase.OnRun() at Microsoft.VisualBasic.ApplicationServices.WindowsFormsApplicationBase.DoApplicationModel() at Microsoft.VisualBasic.ApplicationServices.WindowsFormsApplicationBase.Run(String[] commandLine) at IDE.My.MyApplication.Main(String[] Args) in 17d14f5c-a337-4978-8281-53493378c1071.vb:line 81 at System.AppDomain._nExecuteAssembly(Assembly assembly, String[] args) at System.AppDomain.ExecuteAssembly(String assemblyFile, Evidence assemblySecurity, String[] args) at Microsoft.VisualStudio.HostingProcess.HostProc.RunUsersAssembly() at System.Threading.ThreadHelper.ThreadStart_Context(Object state) at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state) at System.Threading.ThreadHelper.ThreadStart() InnerException:

    Read the article

  • How to configure a GridView CommandField to trigger Full Page Update in UpdatePanel

    - by Frinavale
    I have 2 user controls on my page. One is used for searching, and the other is used for editing (along with a few other things). The user control that provides the search functionality uses a GridView to display the search results. This GridView has a CommandField used for editing (showEditButton="true"). I would like to place the GridView into an UpdatePanel so that paging through the search results will be smooth. The thing is that when the user clicks the Edit Link (the CommandField) I need to preform a full page postback so that the search user control can be hidden and the edit user control can be displayed. Edit: the reason I need to do a full page postback is because the edit user control is outside of the UpdatePanel that my GridView is in. It is not only outside the UpdatePanel, but it's in a completely different user control. I have no idea how to add the CommandField as a full page postback trigger to the UpdatePanel. The PostBackTrigger (which is used to indicate the controls cause a full page postback) takes a ControlID as a parameter; however the CommandButton does not have an ID...and you can see why I'm having a problem with this. Update on what else I've tried to solve the problem: I took a new approach to solving the problem. In my new approach, I used a TemplateField instead of a CommandField. I placed a LinkButton control in the TemplateField and gave it a name. During the GridView's RowDataBound event I retrieved the LinkButton control and added it to the UpdatePanel's Triggers. This is the ASP Markup for the UpdatePanel and the GridView <asp:UpdatePanel ID="SearchResultsUpdateSection" runat="server"> <ContentTemplate> <asp:GridView ID="SearchResultsGrid" runat="server" AllowPaging="true" AutoGenerateColumns="false"> <Columns> <asp:TemplateField> <HeaderTemplate></HeaderTemplate> <ItemTemplate> <asp:LinkButton ID="Edit" runat="server" Text="Edit"></asp:LinkButton> </ItemTemplate> </asp:TemplateField> <asp:BoundField ...... </Columns> </asp:GridView> </ContentTemplate> </asp:UpdatePanel> In my VB.NET code. I implemented a function that handles the GridView's RowDataBound event. In this method I find the LinkButton for the row being bound to, create a PostBackTrigger for the LinkButton, and add it to the UpdatePanel's Triggers. This means that a PostBackTrigger is created for every "edit" LinkButton in the GridView Edit: this did not create a PostBackTrigger for Every "edit" LinkButton because the ID is the same for all LinkButtons in the GridView. Private Sub SearchResultsGrid_RowDataBound(ByVal sender As Object, ByVal e As System.Web.UI.WebControls.GridViewRowEventArgs) Handles SearchResultsGrod.RowDataBound If e.Row.RowType = DataControlRowType.Header Then ''I am doing stuff here that does not pertain to the problem Else Dim editLink As LinkButton = CType(e.Row.FindControl("Edit"), LinkButton) If editLink IsNot Nothing Then Dim fullPageTrigger As New PostBackTrigger fullPageTrigger.ControlID = editLink.ID SearchResultsUpdateSection.Triggers.Add(fullPageTrigger) End If End If End Sub And instead of handling the GridView's RowEditing event for editing purposes i use the RowCommand instead. Private Sub SearchResultsGrid_RowCommand(ByVal sender As Object, ByVal e As System.Web.UI.WebControls.GridViewCommandEventArgs) Handles SearchResultsGrid.RowCommand RaiseEvent EditRecord(Me, New EventArgs()) End Sub This new approach didn't work at all because all of the LinkButtons in the GridView have the same ID. After reading the MSDN article on the UpdatePanel.Triggers Property I have the impression that Triggers can only be defined declaratively. This would mean that anything I did in the VB code wouldn't work. Any advise would be greatly appreciated. Thanks, -Frinny

    Read the article

  • How can I properly implement inetcpl.cpl as an external dll?

    - by Kyt
    I have the following 2 sets of code, both of which produce the same results: using System.Linq; using System.Runtime.InteropServices; using System.Text; using System.Threading.Tasks; using System.Windows.Forms; namespace ResetIE { class Program { [DllImport("InetCpl.cpl", SetLastError=true, CharSet=CharSet.Unicode, EntryPoint="ClearMyTracksByProcessW")] public static extern long ClearMyTracksByProcess(IntPtr hwnd, IntPtr hinst, ref TargetHistory lpszCmdLine, FormWindowState nCmdShow); static void Main(string[] args) { TargetHistory th = TargetHistory.CLEAR_TEMPORARY_INTERNET_FILES; ClearMyTracksByProcessW(Process.GetCurrentProcess().Handle, Marshal.GetHINSTANCE(typeof(Program).Module), ref th, FormWindowState.Maximized); Console.WriteLine("Done."); } } and ... static class NativeMethods { [DllImport("kernel32.dll")] public static extern IntPtr LoadLibrary(string dllToLoad); [DllImport("kernel32.dll")] public static extern IntPtr GetProcAddress(IntPtr hModule, string procedureName); [DllImport("kernel32.dll")] public static extern bool FreeLibrary(IntPtr hModule); } public class CallExternalDLL { [UnmanagedFunctionPointer(CallingConvention.Cdecl)] public delegate long ClearMyTracksByProcessW(IntPtr hwnd, IntPtr hinst, ref TargetHistory lpszCmdLine, FormWindowState nCmdShow); public static void Clear_IE_Cache() { IntPtr pDll = NativeMethods.LoadLibrary(@"C:\Windows\System32\inetcpl.cpl"); if (pDll == IntPtr.Zero) { Console.WriteLine("An Error has Occurred."); } IntPtr pAddressOfFunctionToCall = NativeMethods.GetProcAddress(pDll, "ClearMyTracksByProcessW"); if (pAddressOfFunctionToCall == IntPtr.Zero) { Console.WriteLine("Function Not Found."); } ClearMyTracksByProcessW cmtbp = (ClearMyTracksByProcessW)Marshal.GetDelegateForFunctionPointer(pAddressOfFunctionToCall, typeof(ClearMyTracksByProcessW)); TargetHistory q = TargetHistory.CLEAR_TEMPORARY_INTERNET_FILES; long result = cmtbp(Process.GetCurrentProcess().Handle, Marshal.GetHINSTANCE(typeof(ClearMyTracksByProcessW).Module), ref q, FormWindowState.Normal); } } both use the following Enum: public enum TargetHistory { CLEAR_ALL = 0xFF, CLEAR_ALL_WITH_ADDONS = 0x10FF, CLEAR_HISTORY = 0x1, CLEAR_COOKIES = 0x2, CLEAR_TEMPORARY_INTERNET_FILES = 0x8, CLEAR_FORM_DATA = 0x10, CLEAR_PASSWORDS = 0x20 } Both methods of doing this compile and run just fine, offering no errors, but both churn endlessly never returning from their work. The PInvoke code was ported from the following VB, which was fairly difficult to track down: Option Explicit Private Enum TargetHistory CLEAR_ALL = &HFF& CLEAR_ALL_WITH_ADDONS = &H10FF& CLEAR_HISTORY = &H1& CLEAR_COOKIES = &H2& CLEAR_TEMPORARY_INTERNET_FILES = &H8& CLEAR_FORM_DATA = &H10& CLEAR_PASSWORDS = &H20& End Enum Private Declare Function ClearMyTracksByProcessW Lib "InetCpl.cpl" _ (ByVal hwnd As OLE_HANDLE, _ ByVal hinst As OLE_HANDLE, _ ByRef lpszCmdLine As Byte, _ ByVal nCmdShow As VbAppWinStyle) As Long Private Sub Command1_Click() Dim b() As Byte Dim o As OptionButton For Each o In Option1 If o.Value Then b = o.Tag ClearMyTracksByProcessW Me.hwnd, App.hInstance, b(0), vbNormalFocus Exit For End If Next End Sub Private Sub Form_Load() Command1.Caption = "??" Option1(0).Caption = "?????????????" Option1(0).Tag = CStr(CLEAR_TEMPORARY_INTERNET_FILES) Option1(1).Caption = "Cookie" Option1(1).Tag = CStr(CLEAR_COOKIES) Option1(2).Caption = "??" Option1(2).Tag = CStr(CLEAR_HISTORY) Option1(3).Caption = "???? ???" Option1(3).Tag = CStr(CLEAR_HISTORY) Option1(4).Caption = "?????" Option1(4).Tag = CStr(CLEAR_PASSWORDS) Option1(5).Caption = "?????" Option1(5).Tag = CStr(CLEAR_ALL) Option1(2).Value = True End Sub The question is simply what am I doing wrong? I need to clear the internet cache, and would prefer to use this method as I know it does what I want it to when it works (rundll32 inetcpl.cpl,ClearMyTracksByProcess 8 works fine). I've tried running both as normal user and admin to no avail. This project is written using C# in VS2012 and compiled against .NET3.5 (must remain at 3.5 due to client restrictions)

    Read the article

  • "interface not found" in WCF Moniker without registration for excel

    - by tbischel
    I'm trying to connect excel to a WCF service, but I can't seem to get even a trivial case to work... I get an Invalid Syntax error when I try and create the proxy in excel. I've attached the visual studio debugger to excel, and get that the real error is "interface not found". I know the service works because the test client created by visual studio is ok... so the problem is in the VBA moniker string. I'm hoping to find one of two things: 1) a correction to my moniker string that will make this work, or 2) an existing sample project to download that has the source for both the host and client that does work. Here is the code for my VBA client: Dim addr As String addr = "service:mexAddress=net.tcp://localhost:7891/Test/WcfService1/Service1/mex, " addr = addr + "address=net.tcp://localhost:7891/Test/WcfService1/Service1/, " addr = addr + "contract=IService1, contractNamespace=http://tempuri.org, " addr = addr + "binding=NetTcpBinding_IService1, bindingNamespace=""http://tempuri.org""" MsgBox (addr) Dim service1 As Object Set service1 = GetObject(addr) MsgBox service1.Test(12) I have the following service: [ServiceContract] public interface IService1 { [OperationContract] string GetData(int value); } public class Service1 : IService1 { public string GetData(int value) { return string.Format("You entered: {0}", value); } } It has the following config file: <?xml version="1.0" encoding="utf-8" ?> <configuration> <system.web> <compilation debug="true" /> </system.web> <!-- When deploying the service library project, the content of the config file must be added to the host's app.config file. System.Configuration does not support config files for libraries. --> <system.serviceModel> <services> <service behaviorConfiguration="WcfService1.Service1Behavior" name="WcfService1.Service1"> <endpoint address="" binding="netTcpBinding" bindingConfiguration="" contract="WcfService1.IService1"> <identity> <dns value="localhost" /> </identity> </endpoint> <endpoint address="mex" binding="mexTcpBinding" bindingConfiguration="" contract="IMetadataExchange" /> <host> <baseAddresses> <add baseAddress="net.tcp://localhost:7891/Test/WcfService1/Service1/" /> </baseAddresses> </host> </service> </services> <behaviors> <serviceBehaviors> <behavior name="WcfService1.Service1Behavior"> <serviceMetadata httpGetEnabled="false" /> <serviceDebug includeExceptionDetailInFaults="false" /> </behavior> </serviceBehaviors> </behaviors> </system.serviceModel> </configuration>

    Read the article

  • CustomValidatation control that fire on multiple control events

    - by George
    I am trying to create a UserControl that is a composite control for entering Dates. It involves 2 drop down controls (one for month and one for day) and a text box for year. It also has a CustomValidation control that I would like the user of the UserControl to be able to set the ClientValidationFunction property and have it triggered whenever the value in any of the 3 date part controls changes. To hook up each of the 3 controls to the validation control, I use teh AJAX ValidatorHookupControlID method. If I hard code the following code directly in my aspx page that houses the usercontrol, my Client Validation Function is successfulluy called when any of the 3 date part control values are changed: <script type="text/javascript"> //<![CDATA[ debugger; alert('hooking up'); ValidatorHookupControlID("ctl00_phPageContent_dtmPassportExpirationDate_txtYear", document.all("ctl00_phPageContent_dtmPassportExpirationDate_CustomValidator1")); ValidatorHookupControlID("ctl00_phPageContent_dtmPassportExpirationDate_ddlDate", document.all("ctl00_phPageContent_dtmPassportExpirationDate_CustomValidator1")); ValidatorHookupControlID("ctl00_phPageContent_dtmPassportExpirationDate_ddlMonth", document.all("ctl00_phPageContent_dtmPassportExpirationDate_CustomValidator1")); //]]> However, I would like my usercontrol to emit this Javascript, so I added the following Code. Public Property ClientValidationFunction() As String Get Return CustomValidator1.ClientValidationFunction End Get Set(ByVal value As String) CustomValidator1.ClientValidationFunction = value End Set End Property Public Property EnableClientScript() As Boolean Get Return CustomValidator1.EnableClientScript End Get Set(ByVal value As Boolean) CustomValidator1.EnableClientScript = value End Set End Property Protected Sub Page_PreRender(ByVal sender As Object, ByVal e As System.EventArgs) Handles Me.PreRender If Me.ClientValidationFunction.Trim <> "" AndAlso Me.EnableClientScript Then RegisterValidationScript() End If End Sub Private Sub RegisterValidationScript() Dim Key As String = Me.ClientID & "_ClientValidate" If Not Page.ClientScript.IsClientScriptBlockRegistered(Key) Then Page.ClientScript.RegisterClientScriptBlock(GetType(String), Key, GetJavascript, True) End If End Sub Private Function GetJavascript() As String Dim Out As String = "" Const Quote As String = Chr(34) Out &= "debugger;" & vbCrLf Out &= "ValidatorHookupControlID(" & Quote & txtYear.ClientID & Quote & ", document.all(" & Quote & CustomValidator1.ClientID & Quote & "));" & vbCrLf Out &= "ValidatorHookupControlID(" & Quote & ddlDate.ClientID & Quote & ", document.all(" & Quote & CustomValidator1.ClientID & Quote & "));" & vbCrLf Out &= "ValidatorHookupControlID(" & Quote & ddlMonth.ClientID & Quote & ", document.all(" & Quote & CustomValidator1.ClientID & Quote & "));" & vbCrLf Return Out End Function Unfortunately, when the ValidatorHookupControlID method is called, the second parameter (the one that locates the validation control) always evaluates to null and the method fails. ValidatorHookupControlID("ctl00_phPageContent_DateSelector21_txtYear", document.all("ctl00_phPageContent_DateSelector21_CustomValidator1")); Can you tell me how to correct this error?

    Read the article

  • PHP Image resize - Why is the image uploaded but not resized?

    - by Hans
    BACKGROUND I have a script to upload an image. One to keep the original image and one to resize the image. 1. If the image dimensions (width & height) are within max dimensions I use a simple "copy" direct to folder UserPics. 2. If the original dimensions are bigger than max dimensions I want to resize the width and height to be within max. Both of them are uploading the image to the folder, but in case 2, the image will not be resized. QUESTION Is there something wrong with the script? Is there something wrong with the settings? SETTINGS Server: WAMP 2.0 PHP: 5.3.0 PHP.ini: GD2 enabled, Memory=128M (have tried 1000M) Tried imagetypes uploaded: jpg, jpeg, gif, and png (same result for all of them) SCRIPT //Uploaded image $filename = stripslashes($_FILES['file']['name']); //Read filetype $i = strrpos($filename,"."); if (!$i) { return ""; } $l = strlen($filename) - $i; $extension = substr($filename,$i+1,$l); $extension = strtolower($extension); //New picture name = maxid+1 (from database) $query = mysql_query("SELECT MAX(PicId) AS number FROM userpictures"); $row = mysql_fetch_array($query); $imagenumber = $row['number']+1; //New name of image (including path) $image_name=$imagenumber.'.'.$extension; $newname = "UserPics/".$image_name; //Check width and height of uploaded image list($width,$height)=getimagesize($uploadedfile); //Check memory to hold this image (added only as checkup) $imageInfo = getimagesize($uploadedfile); $requiredMemoryMB = ( $imageInfo[0] * $imageInfo[1] * ($imageInfo['bits'] / 8) * $imageInfo['channels'] * 2.5 ) / 1024; echo $requiredMemoryMB."<br>"; //Max dimensions that can be uploaded $maxwidth = 20; $maxheight = 20; // Check if dimensions shall be original if ($width > $maxwidth || $height > $maxheight) { //Make jpeg from uploaded image if ($extension=="jpg" || $extension=="jpeg" || $extension=="pjpeg" ) { $modifiedimage = imagecreatefromjpeg($uploadedfile); } elseif ($extension=="png") { $modifiedimage = imagecreatefrompng($uploadedfile); } elseif ($extension=="gif") { $modifiedimage = imagecreatefromgif($uploadedfile); } //Change dimensions if ($width > $height) { $newwidth = $maxwidth; $newheight = ($height/$width)*$newwidth; } else { $newheight = $maxheight; $newwidth = ($width/$height)*$newheight; } //Create new image with new dimensions $newdim = imagecreatetruecolor($newwidth,$newheight); imagecopyresized($newdim,$modifiedimage,0,0,0,0,$newwidth,$newheight,$width,$height); imagejpeg($modifiedimage,$newname,60); // Remove temp images imagedestroy($modifiedimage); imagedestroy($newdim); } else { // Just add picture to folder without resize (if org dim < max dim) $newwidth = $width; $newheight = $height; $copied = copy($_FILES['file']['tmp_name'], $newname); } //Add image information to the MySQL database mysql_query("SET character_set_connection=utf8", $dbh); mysql_query("INSERT INTO userpictures (PicId, Picext, UserId, Width, Height, Size) VALUES('$imagenumber', '$extension', '$_SESSION[userid]', '$newwidth', '$newheight', $size)")

    Read the article

  • Gridview delete/edit not working when using select parameter

    - by Brian Carroll
    new to ASP.NET. I created a sqldatasource and set up basic select query (SELECT * FROM Accounts) using the wizard. I then had the sqldatasource wizard create the INSERT, EDIT and DELETE queries. Connected this datasource to a gridview with EDITING and DELETING enabled. Everything works fine. The SELECT query returns all records and I can edit/delete them. Now I need to send a parameter to the SELECT command to filter the records to those with the user's id (pulled from Membership.GetUser). When I add this parameter, the SELECT command works fine, but the EDIT/DELETE buttons in the gridview no longer work. No error is generated. The page refreshes but the records were not updated in the database. I don't understand what is wrong. CODE: <% Dim u As MembershipUser Dim userid As String u = Membership.GetUser(User.Identity.Name) userid = u.ProviderUserKey.ToString SqlDataSource1.SelectParameters("UserId").DefaultValue = userid %> <asp:GridView ID="GridView1" runat="server" AutoGenerateColumns="False" DataKeyNames="ID" DataSourceID="SqlDataSource1"> <Columns> <asp:CommandField ShowDeleteButton="True" ShowEditButton="True" /> <asp:BoundField DataField="ID" HeaderText="ID" InsertVisible="False" ReadOnly="True" SortExpression="ID" /> <asp:BoundField DataField="UserId" HeaderText="UserId" SortExpression="UserId" /> <asp:BoundField DataField="AccountName" HeaderText="AccountName" SortExpression="AccountName" /> <asp:BoundField DataField="DateAdded" HeaderText="DateAdded" SortExpression="DateAdded" /> <asp:BoundField DataField="LastModified" HeaderText="LastModified" SortExpression="LastModified" /> </Columns> </asp:GridView> <asp:SqlDataSource ID="SqlDataSource1" runat="server" ConnectionString="<%$ ConnectionStrings:CheckingConnectionString %>" DeleteCommand="DELETE FROM [Accounts] WHERE [ID] = @ID" InsertCommand="INSERT INTO [Accounts] ([UserId], [AccountName], [DateAdded], [LastModified]) VALUES (@UserId, @AccountName, @DateAdded, @LastModified)" SelectCommand="SELECT * FROM [Accounts] WHERE [UserId] = @UserId" UpdateCommand="UPDATE [Accounts] SET [UserId] = @UserId, [AccountName] = @AccountName, [DateAdded] = @DateAdded, [LastModified] = @LastModified WHERE [ID] = @ID"> <DeleteParameters> <asp:Parameter Name="ID" Type="Int32" /> </DeleteParameters> <InsertParameters> <asp:Parameter Name="UserId" Type="String" /> <asp:Parameter Name="AccountName" Type="String" /> <asp:Parameter Name="DateAdded" Type="DateTime" /> <asp:Parameter Name="LastModified" Type="DateTime" /> </InsertParameters> <UpdateParameters> <asp:Parameter Name="UserId" Type="String" /> <asp:Parameter Name="AccountName" Type="String" /> <asp:Parameter Name="DateAdded" Type="DateTime" /> <asp:Parameter Name="LastModified" Type="DateTime" /> <asp:Parameter Name="ID" Type="Int32" /> </UpdateParameters> <SelectParameters> <asp:Parameter Name="UserId"/> </SelectParameters> </asp:SqlDataSource>

    Read the article

  • Future of VB.NET? [closed]

    - by Alex Yeung
    Hi all, I worked with C# for years. Last year, I changed my job and the company use VB.NET. Of course, theoretically C# and VB.NET are very similar and I easily adapted. However, I have worked for VB.NET for 1 year. I cannot see any future of VB.NET. As a programming language, it is so foo. Here is a list of what C# can do but VB.NET cannot Case insensitive variables how to think a new variable name? If I have a property called FolderPath, i need to establish another private variable called _folderPath or m_folderPath. In C#, FolderPath and folderPath are two variables. Moreover, it gets compile error if variable name is same as a class name. For example Dim guid = Guid.NewGuid(). (What the...) Again, I need to think a new variable name. Adhoc scope In C#, we could use {...} to create a adhoc scope and all resource in {...} will not affect the code outside. However there is not such syntax in VB.NET. I could only use If True Then and End If to make a local scope which is so unclear. In-Method Region Sometime, it is unavoidable to have a long long method. VB.NET does not support in-method region. I always need to scroll down for 1000 lines. It wastes my time. No multi-line string definition In C#, we could var s = @"..." to define a multi-line string. In VB.NET there is no direct method to do that. The indirect way is use XML-literal string. Dim s = <![CDATA[...]]>.Value. However it is unclear. No block comment In C#, we have line comment // and block comment /* ... */. However in VB.NET we only have line comment which is a very big trouble for me. No statement end symbol Statements are separated by line break in VB.NET; while statements are separated by ; in C#. Underscore I think many people know underscore _ is continue statement symbol. I really disagree with that. I know MS VB.NET language team is going to remove the underscore syntax from VB.NET. However what can we do now? Although underscore is removed in the future, what's the advantage of that? I cannot see any advantage! With scope With scope is an evil scope. Although it allows shorter statement, it is hard to trace. Default Namesapce in project level It is a nightmare for me. The only advantage of VB.NET is property initialization. I think C# cannot do that (correct me if I am wrong.) Public Property ThisIsMyProperty As String = "MyValue" Remarks: I don't think optional method parameters is an advantage of OOP. By those disadvantages, I cannot see the future of VB.NET. Anyone sees the future of VB.NET?

    Read the article

  • Add User to Database not working

    - by user1850189
    I'm really new to ASP.net and I am currently trying to create a registration page on a site. I was successful in adding a user to the database but I decided to add another feature into the code to check what userID's were available. For example, if a user deleted their account their userID would become available for use again. I'm trying to find the min value and the max value and add or subtract 1 depending on whether it is min or max. I can run the code I have written for this with no errors but the user is not added to the database. Can anyone help me figure out what I'm missing from my code to do this? EDIT Code adds a user to database but it adds the new user at -1 instead. I don't seem to be able to see where the issue is. If (aDataReader2.Read() = False) Then aConnection1 = New OleDbConnection(aConnectionString) aConnection1.Open() aQuery = "Insert Into UserDetails " aQuery = aQuery & "Values ('" & userID & "','" & userFName & "','" & userLName & "','" & userEmail & "','" & userUsername & "','" & userPassword & "')" aCommand = New OleDbCommand(aQuery, aConnection1) aCommand.ExecuteNonQuery() aConnection1.Close() ElseIf (min = 1) Then aConnection2 = New OleDbConnection(aConnectionString) aConnection2.Open() aCommand = New OleDbCommand(aQuery3, aConnection2) aDataReader2 = aCommand.ExecuteReader() userID = max + 1 aQuery = "Insert Into UserDetails " aQuery = aQuery & "Values ('" & userID & "','" & userFName & "','" & userLName & "','" & userEmail & "','" & userUsername & "','" & userPassword & "')" aCommand = New OleDbCommand(aQuery, aConnection2) aCommand.ExecuteNonQuery() aConnection2.Close() Else aConnection3 = New OleDbConnection(aConnectionString) aConnection3.Open() aCommand = New OleDbCommand(aQuery2, aConnection3) aDataReader2 = aCommand.ExecuteReader userID = min - 1 aQuery = "Insert Into UserDetails " aQuery = aQuery & "Values ('" & userID & "','" & userFName & "','" & userLName & "','" & userEmail & "','" & userUsername & "','" & userPassword & "')" aCommand = New OleDbCommand(aQuery, aConnection3) aCommand.ExecuteNonQuery() aConnection3.Close() lblResults.Text = "User Account successfully created" btnCreateUser.Enabled = False End If Here's the code I used to get the max and min values from the database. I'm getting a value of 0 for both of them - when min should be 1 and max should be 5 Dim minID As Integer Dim maxID As Integer aQuery2 = "Select Min(UserID) AS '" & [minID] & "' From UserDetails" aQuery3 = "Select Max(UserID) AS ' " & [maxID] & "' From UserDetails"

    Read the article

< Previous Page | 53 54 55 56 57 58 59 60 61 62 63 64  | Next Page >