Search Results

Search found 51460 results on 2059 pages for 'simple build tool'.

Page 57/2059 | < Previous Page | 53 54 55 56 57 58 59 60 61 62 63 64  | Next Page >

  • How to Build a Tagging System For Blogs

    In this article I will cover the basics of how to create a tagging system as seen on other blogs. This system will also have the function of adjusting font size depending on the number of articles that have said tag.

    Read the article

  • SQL SERVER – 2011 – Introduction to SEQUENCE – Simple Example of SEQUENCE

    - by pinaldave
    SQL Server 2011 will contain one of the very interesting feature called SEQUENCE. I have waited for this feature for really long time. I am glad it is here finally. SEQUENCE allows you to define a single point of repository where SQL Server will maintain in memory counter. USE AdventureWorks2008R2 GO CREATE SEQUENCE [Seq] AS [int] START WITH 1 INCREMENT BY 1 MAXVALUE 20000 GO SEQUENCE is very interesting concept and I will write few blog post on this subject in future. Today we will see only working example of the same. Let us create a sequence. We can specify various values like start value, increment value as well maxvalue. -- First Run SELECT NEXT VALUE FOR Seq, c.CustomerID FROM Sales.Customer c GO -- Second Run SELECT NEXT VALUE FOR Seq, c.AccountNumber FROM Sales.Customer c GO Once the sequence is defined, it can be fetched using following method. Every single time new incremental value is provided, irrespective of sessions. Sequence will generate values till the max value specified. Once the max value is reached, query will stop and will return error message. Msg 11728, Level 16, State 1, Line 2 The sequence object ‘Seq’ has reached its minimum or maximum value. Restart the sequence object to allow new values to be generated. We can restart the sequence from any particular value and it will work fine. -- Restart the Sequence ALTER SEQUENCE [Seq] RESTART WITH 1 GO -- Sequence Restarted SELECT NEXT VALUE FOR Seq, c.CustomerID FROM Sales.Customer c GO Let us do final clean up. -- Clean Up DROP SEQUENCE [Seq] GO There are lots of things one can find useful about this feature. We will see that in future posts. Here is the complete code for easy reference. USE AdventureWorks2008R2 GO CREATE SEQUENCE [Seq] AS [int] START WITH 1 INCREMENT BY 1 MAXVALUE 20000 GO -- First Run SELECT NEXT VALUE FOR Seq, c.CustomerID FROM Sales.Customer c GO -- Second Run SELECT NEXT VALUE FOR Seq, c.AccountNumber FROM Sales.Customer c GO -- Restart the Sequence ALTER SEQUENCE [Seq] RESTART WITH 1 GO -- Sequence Restarted SELECT NEXT VALUE FOR Seq, c.CustomerID FROM Sales.Customer c GO -- Clean Up DROP SEQUENCE [Seq] GO Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, PostADay, SQL, SQL Authority, SQL Query, SQL Scripts, SQL Server, SQL Tips and Tricks, SQLServer, T SQL, Technology

    Read the article

  • Help with a simple incremental backup script

    - by Evan
    I'd like to run the following incomplete script weekly in as a cron job to backup my home directory to an external drive mounted as /mnt/backups #!/bin/bash # TIMEDATE=$(date +%b-%d-%Y-%k:%M) LASTBACKUP=pathToDirWithLastBackup rsync -avr --numeric-ids --link-dest=$LASTBACKUP /home/myfiles /mnt/backups/myfiles$TIMEDATE My first question is how do I correctly set LASTBACKUP to the the the directory in /backs most recently created? Secondly, I'm under the impression that using --link-desk will mean that files in previous backups will not will not copied in later backups if they still exist but will rather symbolically link back to the originally copied files? However, I don't want to retain old files forever. What would be the best way to remove all the backups before a certain date without losing files that may think linked in those backups by currents backups? Basically I'm looking to merge all the files before a certain date to a certain date if that makes more sense than the way I initially framed the question :). Can --link-dest create hard links, and if so, just deleting previous directories wouldn't actually remove linked file? Finally I'd like to add a line to my script that compresses each newly created backup folder (/mnt/backups/myfiles$TIMEDATE). Based on reading this question, I was wondering if I could just use this line gzip --rsyncable /backups/myfiles$TIMEDATE after I run rsync so that sequential rsync --link-dest executions would find already copied and compressed files? I know that's a lot, so many thanks in advance for your help!!

    Read the article

  • A simple DotNetNuke article module with C# and VB.NET Source

    - by Chris Hammond
    For the DotNetNuke Connections conference last month I provided an advanced DotNetNuke module development course as a pre-conference training session. That training covered details on how to implement some of the newer features in the DotNetNuke platform within custom modules, mainly ContentItem integration and Taxonomy features. For the course I created a very basic Article module for DotNetNuke, ultimately naming it DNNSimpleArticle. For the course I created both a C# and a VB.NET version of the...(read more)

    Read the article

  • HPET for x86 BSP (how to build it for WCE8)

    - by Werner Willemsens
    Originally posted on: http://geekswithblogs.net/WernerWillemsens/archive/2014/08/02/157895.aspx"I needed a timer". That is how we started a few blogs ago our series about APIC and ACPI. Well, here it is. HPET (High Precision Event Timer) was introduced by Intel in early 2000 to: Replace old style Intel 8253 (1981!) and 8254 timers Support more accurate timers that could be used for multimedia purposes. Hence Microsoft and Intel sometimes refers to HPET as Multimedia timers. An HPET chip consists of a 64-bit up-counter (main counter) counting at a frequency of at least 10 MHz, and a set of (at least three, up to 256) comparators. These comparators are 32- or 64-bit wide. The HPET is discoverable via ACPI. The HPET circuit in recent Intel platforms is integrated into the SouthBridge chip (e.g. 82801) All HPET timers should support one-shot interrupt programming, while optionally they can support periodic interrupts. In most Intel SouthBridges I worked with, there are three HPET timers. TIMER0 supports both one-shot and periodic mode, while TIMER1 and TIMER2 are one-shot only. Each HPET timer can generate interrupts, both in old-style PIC mode and in APIC mode. However in PIC mode, interrupts cannot freely be chosen. Typically IRQ11 is available and cannot be shared with any other interrupt! Which makes the HPET in PIC mode virtually unusable. In APIC mode however more IRQs are available and can be shared with other interrupt generating devices. (Check the datasheet of your SouthBridge) Because of this higher level of freedom, I created the APIC BSP (see previous posts). The HPET driver code that I present you here uses this APIC mode. Hpet.reg [HKEY_LOCAL_MACHINE\Drivers\BuiltIn\Hpet] "Dll"="Hpet.dll" "Prefix"="HPT" "Order"=dword:10 "IsrDll"="giisr.dll" "IsrHandler"="ISRHandler" "Priority256"=dword:50 Because HPET does not reside on the PCI bus, but can be found through ACPI as a memory mapped device, you don't need to specify the "Class", "SubClass", "ProgIF" and other PCI related registry keys that you typically find for PCI devices. If a driver needs to run its internal thread(s) at a certain priority level, by convention in Windows CE you add the "Priority256" registry key. Through this key you can easily play with the driver's thread priority for better response and timer accuracy. See later. Hpet.cpp (Hpet.dll) This cpp file contains the complete HPET driver code. The file is part of a folder that you typically integrate in your BSP (\src\drivers\Hpet). It is written as sample (example) code, you most likely want to change this code to your specific needs. There are two sets of #define's that I use to control how the driver works. _TRIGGER_EVENT or _TRIGGER_SEMAPHORE: _TRIGGER_EVENT will let your driver trigger a Windows CE Event when the timer expires, _TRIGGER_SEMAPHORE will trigger a Windows CE counting Semaphore. The latter guarantees that no events get lost in case your application cannot always process the triggers fast enough. _TIMER0 or _TIMER2: both timers will trigger an event or semaphore periodically. _TIMER0 will use a periodic HPET timer interrupt, while _TIMER2 will reprogram a one-shot HPET timer after each interrupt. The one-shot approach is interesting if the frequency you wish to generate is not an even multiple of the HPET main counter frequency. The sample code uses an algorithm to generate a more correct frequency over a longer period (by reducing rounding errors). _TIMER1 is not used in the sample source code. HPT_Init() will locate the HPET I/O memory space, setup the HPET counter (_TIMER0 or _TIMER2) and install the Interrupt Service Thread (IST). Upon timer expiration, the IST will run and on its turn will generate a Windows CE Event or Semaphore. In case of _TIMER2 a new one-shot comparator value is calculated and set for the timer. The IRQ of the HPET timers are programmed to IRQ22, but you can choose typically from 20-23. The TIMERn_INT_ROUT_CAP bits in the TIMn_CONF register will tell you what IRQs you can choose from. HPT_IOControl() can be used to set a new HPET counter frequency (actually you configure the counter timeout value in microseconds), start and stop the timer, and request the current HPET counter value. The latter is interesting because the Windows CE QueryPerformanceCounter() and QueryPerformanceFrequency() APIs implement the same functionality, albeit based on other counter implementations. HpetDrvIst() contains the IST code. DWORD WINAPI HpetDrvIst(LPVOID lpArg) { psHpetDeviceContext pHwContext = (psHpetDeviceContext)lpArg; DWORD mainCount = READDWORD(pHwContext->g_hpet_va, GenCapIDReg + 4); // Main Counter Tick period (fempto sec 10E-15) DWORD i = 0; while (1) { WaitForSingleObject(pHwContext->g_isrEvent, INFINITE); #if defined(_TRIGGER_SEMAPHORE) LONG p = 0; BOOL b = ReleaseSemaphore(pHwContext->g_triggerEvent, 1, &p); #elif defined(_TRIGGER_EVENT) BOOL b = SetEvent(pHwContext->g_triggerEvent); #else #pragma error("Unknown TRIGGER") #endif #if defined(_TIMER0) DWORD currentCount = READDWORD(pHwContext->g_hpet_va, MainCounterReg); DWORD comparator = READDWORD(pHwContext->g_hpet_va, Tim0_ComparatorReg + 0); SETBIT(pHwContext->g_hpet_va, GenIntStaReg, 0); // clear interrupt on HPET level InterruptDone(pHwContext->g_sysIntr); // clear interrupt on OS level _LOGMSG(ZONE_INTERRUPT, (L"%s: HpetDrvIst 0 %06d %08X %08X", pHwContext->g_id, i++, currentCount, comparator)); #elif defined(_TIMER2) DWORD currentCount = READDWORD(pHwContext->g_hpet_va, MainCounterReg); DWORD previousComparator = READDWORD(pHwContext->g_hpet_va, Tim2_ComparatorReg + 0); pHwContext->g_counter2.QuadPart += pHwContext->g_comparator.QuadPart; // increment virtual counter (higher accuracy) DWORD comparator = (DWORD)(pHwContext->g_counter2.QuadPart >> 8); // "round" to real value WRITEDWORD(pHwContext->g_hpet_va, Tim2_ComparatorReg + 0, comparator); SETBIT(pHwContext->g_hpet_va, GenIntStaReg, 2); // clear interrupt on HPET level InterruptDone(pHwContext->g_sysIntr); // clear interrupt on OS level _LOGMSG(ZONE_INTERRUPT, (L"%s: HpetDrvIst 2 %06d %08X %08X (%08X)", pHwContext->g_id, i++, currentCount, comparator, comparator - previousComparator)); #else #pragma error("Unknown TIMER") #endif } return 1; } The following figure shows how the HPET hardware interrupt via ISR -> IST is translated in a Windows CE Event or Semaphore by the HPET driver. The Event or Semaphore can be used to trigger a Windows CE application. HpetTest.cpp (HpetTest.exe)This cpp file contains sample source how to use the HPET driver from an application. The file is part of a separate (smart device) VS2013 solution. It contains code to measure the generated Event/Semaphore times by means of GetSystemTime() and QueryPerformanceCounter() and QueryPerformanceFrequency() APIs. HPET evaluation If you scan the internet about HPET, you'll find many remarks about buggy HPET implementations and bad performance. Unfortunately that is true. I tested the HPET driver on an Intel ICH7M SBC (release date 2008). When a HPET timer expires on the ICH7M, an interrupt indeed is generated, but right after you clear the interrupt, a few more unwanted interrupts (too soon!) occur as well. I tested and debugged it for a loooong time, but I couldn't get it to work. I concluded ICH7M's HPET is buggy Intel hardware. I tested the HPET driver successfully on a more recent NM10 SBC (release date 2013). With the NM10 chipset however, I am not fully convinced about the timer's frequency accuracy. In the long run - on average - all is fine, but occasionally I experienced upto 20 microseconds delays (which were immediately compensated on the next interrupt). Of course, this was all measured by software, but I still experienced the occasional delay when both the HPET driver IST thread as the application thread ran at CeSetThreadPriority(1). If it is not the hardware, only the kernel can cause this delay. But Windows CE is an RTOS and I have never experienced such long delays with previous versions of Windows CE. I tested and developed this on WCE8, I am not heavily experienced with it yet. Internet forum threads however mention inaccurate HPET timer implementations as well. At this moment I haven't figured out what is going on here. Useful references: http://www.intel.com/content/dam/www/public/us/en/documents/technical-specifications/software-developers-hpet-spec-1-0a.pdf http://en.wikipedia.org/wiki/High_Precision_Event_Timer http://wiki.osdev.org/HPET Windows CE BSP source file package for HPET in MyBsp Note that this source code is "As Is". It is still under development and I cannot (and never will) guarantee the correctness of the code. Use it as a guide for your own HPET integration.

    Read the article

  • Command line tool for MediaWiki?

    - by Magnus
    Is there a command line tool that would allow me to script creation of accounts on a MediaWiki instance? The UI for creating an account is painful, and very time consuming when tasked with creating 10+ accounts at a time. Unfortunately I can't get ImportUsers to work due to the very old version of MediaWiki we use (and upgrading is unfortunately not possible at this time).

    Read the article

  • Running TeamCity from Amazon EC2 - Cloud based scalable build and continuous Integration

    Ive been having fun playing with the amazon EC2 cloud service. I set up a server running TeamCity, and an image of a server that just runs a TeamCity agent. I also setup TeamCity  to automatically instantiate agents on EC2 and shut them down based upon availability of free agents. Heres how I did it: The first step was setting up the teamcity server. Create an account on amazon EC2 (BTW, amazons sites works better in IE than it does in chrome.. who knew!?) Open the EC2 dashboard, and...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Running TeamCity from Amazon EC2 - Cloud based scalable build and continuous Integration

    - by RoyOsherove
    I’ve been having fun playing with the amazon EC2 cloud service. I set up a server running TeamCity, and an image of a server that just runs a TeamCity agent. I also setup TeamCity  to automatically instantiate agents on EC2 and shut them down based upon availability of free agents. Here’s how I did it: The first step was setting up the teamcity server. Create an account on amazon EC2 (BTW, amazon’s sites works better in IE than it does in chrome.. who knew!?) Open the EC2 dashboard, and click “Launch Instance” . From the “Quick Start” tab I selected from the list: “Getting Started on Microsoft Windows Server 2008 (AMI Id: ami-c5e40dac)” .  it’s good enough to just run teamcity. In the instance details, I used the default (Small instance, 1.7 GB mem). You might want to choose a close availability zone based on where you are. We want to “Launch instances” so click continue. Select the default kernel, RAM disk and all. No need to enable monitoring for now (you can do that later). click continue. If you don’t have a key pair, you will be prompted to create one. Once you do, select it in the list. Now you’ll be prompted to create a security group. I named mine “TC” as in “TeamCity”. each group is a bunch of settings on which ports can be let through into and out of a hosted machine.  keep it as the default settings. We will change them later. Click continue,  review and then click “Launch”. Now you’ll be able to see the new instance in the running instances list on your site. Now, you need to install stuff on that instance (TeamCity!) . To do that, you’ll need to Remote desktop into that instance. To do that, we’ll get the admin password for that instance: Check it on the list, and click “Instance Actions” - “Get Windows Admin Password”. You might have to wait about 10 minutes or so for the password to be generated for you. Once you have the password, you will remote desktop (start-run-‘mstsc’) into the instance. It’s address is a dns address shown below the list under “Public DNS”. it looks something like: ec2-256-226-194-91.compute-1.amazonaws.com Once you’re inside the instance – you’ll need to open IE (it is in hardened mode so you’ll have to relax its security settings to download stuff). I first downloaded chrome and using chrome I downloaded TeamCity. Note that the download speed is FAST. several MBs per second. To be able to see TeamCity from the outside, you will need to open the advanced firewall settings inside the remote machine, and add incoming and outgoing rules for port 80 (HTTP). Once you do that, you should be able to see the machine from the outside. If you still can’t, see the next step. I also enabled ports 9090 since I will use this machine to create an agent image later as well. Now configure the security group (TC) to enable talking to agents: IN the EC2 dashboard click on “Security Groups” and select your group. To add a rule, click on the empty list under the ‘protocol’ header. select TCP. from and ‘to’ ports are 9090. source ip is 0.0.0.0/0 (every ip is allowed). click “Save.  Also make sure you can see “HTTP” tcp 80 in that list. if you can’t see it, add it or you won’t be able to browse to the machine’s teamcity server home page. I also set an elastic IP for the machine: so I always have the same IP for the machine instance. Allocate and set one through the”Elastic IP” link on the EC2 dashboard.   you should now have a working instance of teamcity.   Now let’s create an agent image. Repeat steps 1-9, but this time, make sure you select a machine that fits what an agent might do. I selected Instance type – Hihg-CPU medium machine,  that is much faster. On that machine, I installed what I needed (VS 2010, PostSharp etc..). downloading VS 2010 from MSDN (2 GB took less than 10 min!) Now, instead of installing teamcity, browse using the browser to the teamcity homepage (from within the remote machine). go to the Administration page, and click the upper right link “Install agents”. Install the agent on he local machine – set it to the IP or DNS of the running TeamCity server. That way you’ll be able to check their connectivity live before making this machine your official agent image to reuse. Once the agent is installed, see that the TC server can see it and use it. see steps 13-14 above if they can’t. Once it works, you can take steps to make this image your agent image to be reused. next, here is a copy-paste of several steps to take from http://confluence.jetbrains.net/display/TCD5/Setting+Up+TeamCity+for+Amazon+EC2 Configure system so that agent it is started on machine boot (and make sure TeamCity server is accessible on machine boot). Test the setup by rebooting machine and checking that the agent connects normally to the server. Prepare the Image for bundling: Remove any temporary/history information in the system. Stop the agent (under Windows stop the service but leave it in Automatic startup type) Delete content agent logs and temp directories (not necessary) Delete "<Agent Home>/conf/amazon-*" file (not necessary) Change config/buildAgent.properties to remove properties: name, serverAddress, authToken (not necessary)   Now, we need to: Make AMI from the running instance. Configure TeamCity EC2 support on TeamCity server. Making an AMI: Check the instance of the agent in the EC2 dashboard instance list, and select instance actions->Create Image (EBS AMI) you’ll see the image pending in the APIs list in the EC2 dashboard. this could take 30 minutes or more. meanwhile we can configure the could support in the teamcity server. COPY THE AMI ID to the clipboard (looks like ami-a88aa4ce) Configuring TeamCity for Cloud: In TeamCity, click on “Agents” and then on “Cloud” tab. this is where you will control your cloud agents. to configure new cloud agents based on APIs, click on the right link to the “configuration page” Create a new profile and select AMazon EC2 as cloud type. Use your AMI ID that you copied to the clipboard into the “Images” field. Select an availability zone that is the same as the one your instance is running on for best communication perf between them make sure you select the ‘TC’ security group hopefully, that should be it, and teamcity will try to instantiate new instances on demand. Note that it may take around 10 minutes for an agent to become available to teamcity from the time it’s started.

    Read the article

  • Running TeamCity from Amazon EC2 - Cloud based scalable build and continuous Integration

    Ive been having fun playing with the amazon EC2 cloud service. I set up a server running TeamCity, and an image of a server that just runs a TeamCity agent. I also setup TeamCity  to automatically instantiate agents on EC2 and shut them down based upon availability of free agents. Heres how I did it: The first step was setting up the teamcity server. Create an account on amazon EC2 (BTW, amazons sites works better in IE than it does in chrome.. who knew!?) Open the EC2 dashboard, and...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • What's the fastest filesystem for developer builds?

    - by Dan Fabulich
    I'm putting together a Linux box that will act as a continuous integration build server; we'll mostly build Java stuff, but I think this question applies to any compiled language. What filesystem and configuration settings should I use? (For example, I know I won't need atime for this!) The build server will spend a lot of time reading and writing small files, and scanning directories to see which files have been modified.

    Read the article

  • A simple example of validation in ASP.Net applications

    - by nikolaosk
    I am going to start a new series of posts and I am going to cover in depth all the validation mechanisms/techniques/controls we have available in our ASP.Net applications. As many of you may know I am a Microsoft Certified Trainer and I will present this series of posts from a trainer's point of view. This series of posts will be helpful to all of novice/intermediate programmers who want to see all the tools available for validating data in ASP.Net applications. I am not going to try to convince...(read more)

    Read the article

  • Best Practices To Build a Product Registration System?

    - by Volomike
    What are some practices I should use in a product registration system I'm building? I likely can't stop all malicious hacking, but I'd like to slow them down a great deal. (Note, I know only PHP.) I'm talking about things like encrypting traffic, testing the encryption from hacking like a man-in-the-middle attack, etc. The other concern I have is that this needs to work on most PHP5-based web hosting environments, which may not have mcrypt installed.

    Read the article

  • GTD tool for Mac OS X and iPhone?

    - by harald
    I am looking for a GTD (getting things done) tool, which there is a OS X and an iPhone app available. I don't want any web based stuff, but native applications. The Mac application needs some functionality for synchronization with the iPhone app. Are there any GTD apps, which fit my requirements?

    Read the article

  • FAT filesystem analysis tool

    - by Andy
    I have a dump a FAT file system. Is there a windows tool I can use to analyse it, including: Provide basic information (sector size etc.) Validate the file system, basic corruption checking Allow the files and directory structure to be viewed and possibly edited (i.e mounting as a windows partition) Thanks, Andy

    Read the article

  • Silverlight TV 17: Build a Twitter Client for Windows Phone 7 with Silverlight

      At MIX10 this week it was announced that you can develop Windows Phone 7 apps using Silverlight! In this episode, Mike Harsh comes back to Silverlight TV to show John how easy it is to develop a real world application for Windows Phone 7 Series (WP7) using Silverlight. Within minutes, Mike has developed and started running a functional WP7 twitter application that makes cross domain calls. He demonstrates how to design the interface using the designer and tools in Visual Studio 2010 Express...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Begining a simple game development. [closed]

    - by Vinod Maurya
    Hi, I have searched a lot about beginning the game development but I didn't found the appropriate answer which I am looking in fact I got more confused. What I want to know is which game engine, modeling programs (I know only 2, please tell me if there is some other) to use? For the beginning, I want to use some free game engines for learning purpose. I am an absolute beginner in game development. I have a good programming experience in C++, VB, Java, C#. Thanks.

    Read the article

  • Windows 8: Everything from design, build, and how to sell a Metro style app

    - by Thomas Mason
    For me, there are a lot of similarities between an application developed for Windows Phone and a Metro style app developed for Windows 8. A Windows Phone 7 application (rather than an XNA game) is built in .NET and XAML against a subset of the .NET framework and the application has a lifecycle which needs to be conscious of battery life and so is split out into foreground/background pieces. The application is sandboxed in terms of its interactions with the local device and is packaged with a manifest which describes those interactions. The app needs to be aware of network connectivity status and its work on the network is done asynchronously to preserve the user experience.The app is packaged and deployed to a Marketplace which the user browses to find the app, read reviews, perhaps purchase it and then install it and receive updates over time. Quite a lot of those statements are as true of a Windows 8 Metro style app as they are for a Windows Phone app and so a Windows Phone app developer already has a good head start when it comes to building Metro style apps for Windows 8. With that in mind, there is an event to help developers with a Windows Phone app in Marketplace to begin the process of looking at Windows 8 and whether you can get a quick win by bringing your Phone application onto Windows. The idea of the event was to provide a space where developers can get together over 2 days and take the time out to look at what it means to take their app from Windows Phone to Windows 8. Kicking off on Saturday 16th June at 10am, we are told they have plenty of power sockets, WiFi, whiteboards, drinks, pizza, games, prizes and some quiet space that you can work in. Including people on hand with Windows Phone and Windows 8 experience to help everything along the way. There will be an attendee-voted schedule of talks but we’ll keep these out of your way if you just want to get on and code. We’ll also provide information around submitting your app to the Windows Store If you have a Windows Phone app in Marketplace, now’s a great time to look at getting it onto Windows 8. Sign up. Bring your laptop. Bring your app. Bring Windows 8 and Visual Studio 11. And everyone will their best to help you get your app onto Windows 8. Location & Venue TBA but it will be in central London, accessible by major railway and underground transportation. Day 1 Saturday 16th June 10am – 9pm Day 2 Sunday 17th June 10am – 4pm

    Read the article

  • SQL SERVER – Simple Demo of New Cardinality Estimation Features of SQL Server 2014

    - by Pinal Dave
    SQL Server 2014 has new cardinality estimation logic/algorithm. The cardinality estimation logic is responsible for quality of query plans and majorly responsible for improving performance for any query. This logic was not updated for quite a while, but in the latest version of SQL Server 2104 this logic is re-designed. The new logic now incorporates various assumptions and algorithms of OLTP and warehousing workload. Cardinality estimates are a prediction of the number of rows in the query result. The query optimizer uses these estimates to choose a plan for executing the query. The quality of the query plan has a direct impact on improving query performance. ~ Souce MSDN Let us see a quick example of how cardinality improves performance for a query. I will be using the AdventureWorks database for my example. Before we start with this demonstration, remember that even though you have SQL Server 2014 to see the effect of new cardinality estimates, you will need your database compatibility mode set to 120 which is for SQL Server 2014. If your server instance of SQL Server 2014 but you have set up your database compatibility mode to 110 or any other earlier version, you will get performance from your query like older version of SQL Server. Now we will execute following query in two different compatibility mode and see its performance. (Note that my SQL Server instance is of version 2014). USE AdventureWorks2014 GO -- ------------------------------- -- NEW Cardinality Estimation ALTER DATABASE AdventureWorks2014 SET COMPATIBILITY_LEVEL = 120 GO EXEC [dbo].[uspGetManagerEmployees] 44 GO -- ------------------------------- -- Old Cardinality Estimation ALTER DATABASE AdventureWorks2014 SET COMPATIBILITY_LEVEL = 110 GO EXEC [dbo].[uspGetManagerEmployees] 44 GO Result of Statistics IO Compatibility level 120 Table ‘Person’. Scan count 0, logical reads 6, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table ‘Employee’. Scan count 2, logical reads 7, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table ‘Worktable’. Scan count 0, logical reads 0, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table ‘Worktable’. Scan count 2, logical reads 7, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Compatibility level 110 Table ‘Worktable’. Scan count 2, logical reads 7, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table ‘Person’. Scan count 0, logical reads 137, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table ‘Employee’. Scan count 2, logical reads 7, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. Table ‘Worktable’. Scan count 0, logical reads 0, physical reads 0, read-ahead reads 0, lob logical reads 0, lob physical reads 0, lob read-ahead reads 0. You will notice in the case of compatibility level 110 there 137 logical read from table person where as in the case of compatibility level 120 there are only 6 physical reads from table person. This drastically improves the performance of the query. If we enable execution plan, we can see the same as well. I hope you will find this quick example helpful. You can read more about this in my latest Pluralsight Course. Reference: Pinal Dave (http://blog.SQLAuthority.com)Filed under: PostADay, SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, T SQL

    Read the article

  • Simple Netduino Go Tutorial Flashing RGB LEDs with a potentiometer

    - by Chris Hammond
    In case you missed the announcement on 4/4, the guys and Secret Labs, along with other members of the Netduino Community have come out with a new platform called Netduino Go . Head on over www.netduino.com for the introduction forum post . This post is how to quickly get up and running with your Netduino Go, based on Chris Walker’s getting started forum post , with some enhancements that I think will make it easier to get up and running, as Chris’ post unfortunately leaves a few things out. Hardware...(read more)

    Read the article

< Previous Page | 53 54 55 56 57 58 59 60 61 62 63 64  | Next Page >