Search Results

Search found 18892 results on 756 pages for 'display'.

Page 572/756 | < Previous Page | 568 569 570 571 572 573 574 575 576 577 578 579  | Next Page >

  • SQL Server Express 2008 R2 Installation error at Windows 7

    - by Shai Sherman
    Hello, I created install script that will install SQL Server 2008 R2 on windows XP SP3, windows vista and windows 7. One of the command that i used in the installation is for silent installation of SQL Server 2008 R2. When i install it on windows XP everything works just fine but when i try to install it on Windows 7 i get an error. What am I doing wrong? Here is the command line that i use: "Setup.exe /ConfigurationFile=Mysetup.ini" Mysetup.ini file: -------------------------------------Start of ini file --------------------------------- ;SQL SERVER 2008 R2 Configuration File ;Version 1.0, 5 May 2010 ; [SQLSERVER2008] ; Specify the Instance ID for the SQL Server features you have specified. SQL Server directory structure, registry structure, and service names will reflect the instance ID of the SQL Server instance. INSTANCEID="MSSQLSERVER" ; Specifies a Setup work flow, like INSTALL, UNINSTALL, or UPGRADE. This is a required parameter. ACTION="Install" ; Specifies features to install, uninstall, or upgrade. The list of top-level features include SQL, AS, RS, IS, and Tools. The SQL feature will install the database engine, replication, and full-text. The Tools feature will install Management Tools, Books online, Business Intelligence Development Studio, and other shared components. FEATURES=SQLENGINE ; Displays the command line parameters usage HELP="False" ; Specifies that the detailed Setup log should be piped to the console. INDICATEPROGRESS="False" ; Setup will not display any user interface. QUIET="False" ; Setup will display progress only without any user interaction. QUIETSIMPLE="True" ; Specifies that Setup should install into WOW64. This command line argument is not supported on an IA64 or a 32-bit system. ;X86="False" ; Specifies the path to the installation media folder where setup.exe is located. ;MEDIASOURCE="z:\" ; Detailed help for command line argument ENU has not been defined yet. ENU="True" ; Parameter that controls the user interface behavior. Valid values are Normal for the full UI, and AutoAdvance for a simplied UI. ; UIMODE="Normal" ; Specify if errors can be reported to Microsoft to improve future SQL Server releases. Specify 1 or True to enable and 0 or False to disable this feature. ERRORREPORTING="False" ; Specify the root installation directory for native shared components. ;INSTALLSHAREDDIR="D:\Program Files\Microsoft SQL Server" ; Specify the root installation directory for the WOW64 shared components. ;INSTALLSHAREDWOWDIR="D:\Program Files (x86)\Microsoft SQL Server" ; Specify the installation directory. ;INSTANCEDIR="D:\Program Files\Microsoft SQL Server" ; Specify that SQL Server feature usage data can be collected and sent to Microsoft. Specify 1 or True to enable and 0 or False to disable this feature. SQMREPORTING="False" ; Specify a default or named instance. MSSQLSERVER is the default instance for non-Express editions and SQLExpress for Express editions. This parameter is required when installing the SQL Server Database Engine (SQL), Analysis Services (AS), or Reporting Services (RS). INSTANCENAME="SQLEXPRESS" SECURITYMODE=SQL SAPWD=SystemAdmin ; Agent account name AGTSVCACCOUNT="NT AUTHORITY\NETWORK SERVICE" ; Auto-start service after installation. AGTSVCSTARTUPTYPE="Manual" ; Startup type for Integration Services. ;ISSVCSTARTUPTYPE="Automatic" ; Account for Integration Services: Domain\User or system account. ;ISSVCACCOUNT="NT AUTHORITY\NetworkService" ; Controls the service startup type setting after the service has been created. ;ASSVCSTARTUPTYPE="Automatic" ; The collation to be used by Analysis Services. ;ASCOLLATION="Latin1_General_CI_AS" ; The location for the Analysis Services data files. ;ASDATADIR="Data" ; The location for the Analysis Services log files. ;ASLOGDIR="Log" ; The location for the Analysis Services backup files. ;ASBACKUPDIR="Backup" ; The location for the Analysis Services temporary files. ;ASTEMPDIR="Temp" ; The location for the Analysis Services configuration files. ;ASCONFIGDIR="Config" ; Specifies whether or not the MSOLAP provider is allowed to run in process. ;ASPROVIDERMSOLAP="1" ; A port number used to connect to the SharePoint Central Administration web application. ;FARMADMINPORT="0" ; Startup type for the SQL Server service. SQLSVCSTARTUPTYPE="Automatic" ; Level to enable FILESTREAM feature at (0, 1, 2 or 3). FILESTREAMLEVEL="0" ; Set to "1" to enable RANU for SQL Server Express. ENABLERANU="1" ; Specifies a Windows collation or an SQL collation to use for the Database Engine. SQLCOLLATION="SQL_Latin1_General_CP1_CI_AS" ; Account for SQL Server service: Domain\User or system account. SQLSVCACCOUNT="NT Authority\System" ; Default directory for the Database Engine user databases. ;SQLUSERDBDIR="K:\Microsoft SQL Server\MSSQL\Data" ; Default directory for the Database Engine user database logs. ;SQLUSERDBLOGDIR="L:\Microsoft SQL Server\MSSQL\Data\Logs" ; Directory for Database Engine TempDB files. ;SQLTEMPDBDIR="T:\Microsoft SQL Server\MSSQL\Data" ; Directory for the Database Engine TempDB log files. ;SQLTEMPDBLOGDIR="T:\Microsoft SQL Server\MSSQL\Data\Logs" ; Provision current user as a Database Engine system administrator for SQL Server 2008 R2 Express. ADDCURRENTUSERASSQLADMIN="True" ; Specify 0 to disable or 1 to enable the TCP/IP protocol. TCPENABLED="1" ; Specify 0 to disable or 1 to enable the Named Pipes protocol. NPENABLED="0" ; Startup type for Browser Service. BROWSERSVCSTARTUPTYPE="Automatic" ; Specifies how the startup mode of the report server NT service. When ; Manual - Service startup is manual mode (default). ; Automatic - Service startup is automatic mode. ; Disabled - Service is disabled ;RSSVCSTARTUPTYPE="Automatic" ; Specifies which mode report server is installed in. ; Default value: “FilesOnly” ;RSINSTALLMODE="FilesOnlyMode" ; Accept SQL Server 2008 R2 license terms IACCEPTSQLSERVERLICENSETERMS="TRUE" ;setup.exe /CONFIGURATIONFILE=Mysetup.ini /INDICATEPROGRESS --------------------------- End of ini file ------------------------------------- And i get this error: 2010-08-31 18:05:53 Slp: Error result: -2068119551 2010-08-31 18:05:53 Slp: Result facility code: 1211 2010-08-31 18:05:53 Slp: Result error code: 1 2010-08-31 18:05:53 Slp: Sco: Attempting to create base registry key HKEY_LOCAL_MACHINE, machine 2010-08-31 18:05:53 Slp: Sco: Attempting to open registry subkey 2010-08-31 18:05:53 Slp: Sco: Attempting to open registry subkey Software\Microsoft\PCHealth\ErrorReporting\DW\Installed 2010-08-31 18:05:53 Slp: Sco: Attempting to get registry value DW0200 2010-08-31 18:05:53 Slp: Submitted 1 of 1 failures to the Watson data repository What the meaning of this? What do i need to do to fix that problem? Here is the Summary file: Overall summary: Final result: SQL Server installation failed. To continue, investigate the reason for the failure, correct the problem, uninstall SQL Server, and then rerun SQL Server Setup. Exit code (Decimal): -2068119551 Exit facility code: 1211 Exit error code: 1 Exit message: SQL Server installation failed. To continue, investigate the reason for the failure, correct the problem, uninstall SQL Server, and then rerun SQL Server Setup. Start time: 2010-08-31 18:03:44 End time: 2010-08-31 18:05:51 Requested action: Install Log with failure: C:\Program Files\Microsoft SQL Server\100\Setup Bootstrap\Log\20100831_180236\Detail.txt Exception help link: http%3a%2f%2fgo.microsoft.com%2ffwlink%3fLinkId%3d20476%26ProdName%3dMicrosoft%2bSQL%2bServer%26EvtSrc%3dsetup.rll%26EvtID%3d50000%26ProdVer%3d10.50.1600.1%26EvtType%3d0x6121810A%400xC24842DB Machine Properties: Machine name: NVR Machine processor count: 2 OS version: Windows 7 OS service pack: OS region: United States OS language: English (United States) OS architecture: x86 Process architecture: 32 Bit OS clustered: No Product features discovered: Product Instance Instance ID Feature Language Edition Version Clustered Package properties: Description: SQL Server Database Services 2008 R2 ProductName: SQL Server 2008 R2 Type: RTM Version: 10 SPLevel: 0 Installation location: C:\Disk1\setupsql\x86\setup\ Installation edition: EXPRESS User Input Settings: ACTION: Install ADDCURRENTUSERASSQLADMIN: True AGTSVCACCOUNT: NT AUTHORITY\NETWORK SERVICE AGTSVCPASSWORD: * AGTSVCSTARTUPTYPE: Disabled ASBACKUPDIR: Backup ASCOLLATION: Latin1_General_CI_AS ASCONFIGDIR: Config ASDATADIR: Data ASDOMAINGROUP: ASLOGDIR: Log ASPROVIDERMSOLAP: 1 ASSVCACCOUNT: ASSVCPASSWORD: * ASSVCSTARTUPTYPE: Automatic ASSYSADMINACCOUNTS: ASTEMPDIR: Temp BROWSERSVCSTARTUPTYPE: Automatic CONFIGURATIONFILE: C:\Program Files\Microsoft SQL Server\100\Setup Bootstrap\Log\20100831_180236\ConfigurationFile.ini CUSOURCE: ENABLERANU: True ENU: True ERRORREPORTING: False FARMACCOUNT: FARMADMINPORT: 0 FARMPASSWORD: * FEATURES: SQLENGINE FILESTREAMLEVEL: 0 FILESTREAMSHARENAME: FTSVCACCOUNT: FTSVCPASSWORD: * HELP: False IACCEPTSQLSERVERLICENSETERMS: True INDICATEPROGRESS: False INSTALLSHAREDDIR: C:\Program Files\Microsoft SQL Server\ INSTALLSHAREDWOWDIR: C:\Program Files\Microsoft SQL Server\ INSTALLSQLDATADIR: INSTANCEDIR: C:\Program Files\Microsoft SQL Server\ INSTANCEID: MSSQLSERVER INSTANCENAME: SQLEXPRESS ISSVCACCOUNT: NT AUTHORITY\NetworkService ISSVCPASSWORD: * ISSVCSTARTUPTYPE: Automatic NPENABLED: 0 PASSPHRASE: * PCUSOURCE: PID: * QUIET: False QUIETSIMPLE: True ROLE: AllFeatures_WithDefaults RSINSTALLMODE: FilesOnlyMode RSSVCACCOUNT: NT AUTHORITY\NETWORK SERVICE RSSVCPASSWORD: * RSSVCSTARTUPTYPE: Automatic SAPWD: * SECURITYMODE: SQL SQLBACKUPDIR: SQLCOLLATION: SQL_Latin1_General_CP1_CI_AS SQLSVCACCOUNT: NT Authority\System SQLSVCPASSWORD: * SQLSVCSTARTUPTYPE: Automatic SQLSYSADMINACCOUNTS: SQLTEMPDBDIR: SQLTEMPDBLOGDIR: SQLUSERDBDIR: SQLUSERDBLOGDIR: SQMREPORTING: False TCPENABLED: 1 UIMODE: AutoAdvance X86: False Configuration file: C:\Program Files\Microsoft SQL Server\100\Setup Bootstrap\Log\20100831_180236\ConfigurationFile.ini Detailed results: Feature: Database Engine Services Status: Failed: see logs for details MSI status: Passed Configuration status: Failed: see details below Configuration error code: 0x0A2FBD17@1211@1 Configuration error description: The process cannot access the file because it is being used by another process. Configuration log: C:\Program Files\Microsoft SQL Server\100\Setup Bootstrap\Log\20100831_180236\Detail.txt Rules with failures: Global rules: Scenario specific rules: Rules report file: C:\Program Files\Microsoft SQL Server\100\Setup Bootstrap\Log\20100831_180236\SystemConfigurationCheck_Report.htm What should I do and why does this problem occur? Thanks , Shai.

    Read the article

  • FTP timing out after login

    - by Imran
    For some reasons I cant access any of my accounts on my dedicated server via FTP. It simply times out when it tried to display the directories. Heres a log from FileZila... Status: Resolving address of testdomain.com Status: Connecting to 64.237.58.43:21... Status: Connection established, waiting for welcome message... Response: 220---------- Welcome to Pure-FTPd [TLS] ---------- Response: 220-You are user number 3 of 50 allowed. Response: 220-Local time is now 19:39. Server port: 21. Response: 220-This is a private system - No anonymous login Response: 220-IPv6 connections are also welcome on this server. Response: 220 You will be disconnected after 15 minutes of inactivity. Command: USER testaccount Response: 331 User testaccount OK. Password required Command: PASS ******** Response: 230-User testaccount has group access to: testaccount Response: 230 OK. Current restricted directory is / Command: SYST Response: 215 UNIX Type: L8 Command: FEAT Response: 211-Extensions supported: Response: EPRT Response: IDLE Response: MDTM Response: SIZE Response: REST STREAM Response: MLST type*;size*;sizd*;modify*;UNIX.mode*;UNIX.uid*;UNIX.gid*;unique*; Response: MLSD Response: ESTP Response: PASV Response: EPSV Response: SPSV Response: ESTA Response: AUTH TLS Response: PBSZ Response: PROT Response: 211 End. Status: Connected Status: Retrieving directory listing... Command: PWD Response: 257 "/" is your current location Command: TYPE I Response: 200 TYPE is now 8-bit binary Command: PASV Response: 227 Entering Passive Mode (64,237,58,43,145,153) Command: MLSD Response: 150 Accepted data connection Response: 226-ASCII Response: 226-Options: -a -l Response: 226 18 matches total Error: Connection timed out Error: Failed to retrieve directory listing I have restarted the FTP service serveral times but still It doesnt loads. I only have this problem when my server is reaching it peak usage which is still only 1.0 (4 cores), 40% of 4GB ram. The ftp connections isnt maxed out because only me and my colleague have access to FTP on the server.

    Read the article

  • How can I forward an application with X11 in grayscale

    - by ??????? ???????????
    I am trying to run a graphical application at home and display it on a it on a laptop which is located about six routing hops away. The problem is that the connection is so slow (or rather there is so much GOOEY being transfered) that the mouse is unresponsive and it takes a "long time" to redraw the window even at a resolution of 800x600 pixels. The connection speeds are 10MBit up at home and about 1MBit down on the laptop, which I think should be sufficient for looking at some GUI in (almost) real time. Since this traffic is sent over over a secure shell, I have enabled Compression with highest CompressionLevel along with Ciphers set to blowfish-cbc. This has substantially improved the responsiveness of the application, making it nearly usable. However, my goal is to improve the performance even further by sacrificing colors and even frame rate. The application to be displayed a Qemu SDL window with a graphically-oriented OS in it. This is not strictly relevant, but perhaps there are options to tweak the SDL output which I am not aware of. A possible workaround would be to run the application in a "hidden" X server and enabling TigerVNC on that X server. This would automatically give me the benefits of an optimized VNC viewport, but the goal is to do without (reduce complexity). The question I'm asking is what are my options for reducing the data-rate generated on the server in order to make the graphical application more usable on the client. As mentioned, colors are not important and I could probably work with 5-16 fps. Both machines are running Gentoo with the software in question being: workstation X.Org X Server 1.10.4 OpenSSH_5.8p1-hpn13v10, OpenSSL 1.0.0e QEMU emulator version 0.15.1 (qemu-kvm-0.15.1) laptop X.Org X Server 1.12.2 OpenSSH_5.8p1-hpn13v10lpk, OpenSSL 1.0.0j

    Read the article

  • KVM recommendations

    - by alex
    I recently tried out a cheaper KVM solution, a dual monitor one with a USB hub and audio/mic support. It seemed the perfect KVM. However, these are my experiences. When using my keyboard via the PS/2 connection, none of my multimedia keys work (useful, because it has a volume control and my speakers do not, only on a wireless remote control.) I plugged the keyboard in via the USB port - and it seemed to work. However, I believe to switch the hub from PC to Mac, you need to use a keyboard combo, which is only supported when the keyboard is plugged in via PS/2 Sometimes the middle mouse button doesn't work when connected via PS/2. The multi monitor is VGA - I just found out by the looks of things my Mac Mini outputs DVI Digital only (though this is my fault!). Mac works with 2 screens, but switching and switching back can cause it not to display on the 2nd screen unless I go detect displays again. My question is - is there a KVM out there that supports these features? USB keyboard and mouse inputs will full multimedia keys support Dual monitor DVI connections Hotkey to change PCs and physical button USB hub Emulate screens attached when switching to a different computer Works with PC and Mac Audio / Microphone support Does one exist, that won't cost the world? So far the only one that seems to support all this (that I can tell) is this one. UPDATE I ended up buying the Aten CS1642. It's expensive, but it seems to work great!

    Read the article

  • Cisco ASA Act as a Hardware Security Module?

    - by Derek
    Hello, We have a partner that is requiring us to get a HSM for a web application that we host for them. This is something new for us, we've always installed our SSL certificates on our web servers and never needed a hardware device. We currently have 2 Cisco ASA 5510 firewalls in an active/standby configuration. Both ASAs have a ASA-SSM-10 security module installed in them. The web application is a standard HTTPS webpage with no authentication required. I was wondering if we could use our Cisco ASAs to meet this requirement or if we'll have to buy another device. I was doing some searching and read about Cisco's clientless webvpn feature. It sounds like it might work, but I'm not sure. We basically want the ASA to handle the SSL and proxy the connection to our web servers. We do not want to prompt for a username or password to connect or show any portals, just display the web page. If the ASA cannot do this, does any one have any recommendations for network attached hardware security modules? We are using VMware vCenter, so we'd rather have an external device attached to the network, rather than buying HSM cards for every ESXi host. Thanks, Derek

    Read the article

  • Problems migrating software RAID 5 to new server (linux)

    - by leleu
    I have a CentOS setup with sw RAID5 that holds my data. Well, the server died, so I bought another box to migrate my drives to. Only thing is, I cannot get the RAID array rebuilt (not even sure it needs rebuilding, might just need the /dev/md0 mapping created... but I don't even know how to determine what I need!) Some details: RAID5 software (used mdadm) 4x 250GB drives (2 are SATA, 2 are EIDE -- would this matter? It worked fine in the other box...) latest CentOS distro built using mdadm I've got a decent amount of experience with standard linux stuff, but the hardware level stuff runs me in circles. I've spent some time googling and elsewhere here on SF, so please be kind for my newbie questions :). My question is this: how can I diagnose the problem? For all I know, I'm using the wrong device blocks when I try to rebuild the array, but I can't find the command to display only the devices that have some physical attachment. Is there some simple way for me to run mdadm, having it scan over all my physical drives, and say "hey, drives 2,5,6,7 are a software array, want me to mount it?" I basically just took the drives from my old box and put it into my new one. They show up in the BIOS. What steps do I need to take in order to get the array up, running, and mounted? Thanks in advance!

    Read the article

  • Dual NVidia graphics cards in Ubuntu / xorg.conf mania

    - by John Zwinck
    I have two NVidia graphics cards: Quadro NVS 295 (PCI Express, dual DisplayPort outputs) GeForce FX 5200 (PCI, DVI and VGA outputs) I have three identical monitors, two on DisplayPort and one on DVI. I'm on Ubuntu Hardy (and cannot currently dist-upgrade for separate reasons). I use the "nvidia" driver. What's new is the GeForce card and the third monitor. I currently have the dual DisplayPort monitors working fine. Here are the display-related parts of my xorg.conf: Section "ServerLayout" Identifier "Default Layout" Screen "PCI-Express Screen" 0 0 # adding this makes X fail to start: Screen "PCI Screen" 0 Inputdevice "Generic Keyboard" Inputdevice "Configured Mouse" EndSection Section "Module" Load "glx" # not sure why/if this is needed EndSection Section "Monitor" Identifier "DELL 2408WFP" Option "DPMS" EndSection Section "Device" Identifier "NVIDIA Quadro NVS 295" Driver "nvidia" Option "RenderAccel" "true" Screen 0 BusID "PCI:2:0:0" EndSection Section "Device" Identifier "NVIDIA GeForce FX 5200" Driver "nvidia" Option "RenderAccel" "true" Screen 1 BusID "PCI:6:4:0" EndSection Section "Screen" Identifier "PCI-Express Screen" Device "NVIDIA Quadro NVS 295" Monitor "DELL 2408WFP" Defaultdepth 24 Option "TwinView" "True" Option "UseEdidFreqs" "True" Option "MetaModes" "1920x1200 +0+1200, 1920x1200 +0+0" EndSection Section "Screen" Identifier "PCI Screen" Device "NVIDIA GeForce FX 5200" Monitor "DELL 2408WFP" Defaultdepth 24 Option "TwinView" "True" Option "UseEdidFreqs" "True" Option "MetaModes" "1920x1200 +0+0" EndSection I use nvidia-settings to configure my monitors, and it does not show the second GPU. lspci, though, shows: 02:00.0 VGA compatible controller: nVidia Corporation Unknown device 06fd 06:04.0 VGA compatible controller: nVidia Corporation NV34 [GeForce FX 5200] Which is where I got the BusID settings for the two devices (when I just had one device, I didn't have any BusID listed...and adding the BusID hasn't broken anything). What am I missing? How can I make nvidia-settings show my second GPU so I can then configure its monitor?

    Read the article

  • Ubuntu Server running VNC

    - by xwapilot
    I have access to four computers: 1 Ubuntu Server desktop (Version 10.04) 1 Mac Mini (Snow Leopard) 1 Windows desktop (Windows 7) 1 Windows laptop (Windows Vista) The first three will always be on the home network. My goal is to SSH from the laptop into the server and be able, through VNC (or another remote desktop software), to control the windows and mac computers. The goal of this would be a slightly heightened network security over using VNC to directly access the mac or windows desktop. I have successfully used SSH to connect to the server, but have not been able to successfully implement the remote desktop connection. I would appreciate help doing so. Here's what I've done so far: As per instructions here: http://www.stuartellis.eu/articles/vnc-on-linux/ I installed the following: vnc4server – the main VNC server software vnc-java – enables access from Web browsers with Java support xvnc4viewer – a basic VNC viewer I then set up a password using the vncpasswd command. To attempt to connect to the mac, I followed directions I found in a thread at superuser. com and went to "System PreferencesSharing" and enabled "Screen Sharing". Subsequently, I tried entering the following commands into Ubuntu: vncviewer mac_ip_address::5904 vncviewer mac_ip_address:0 vncviewer mac_ip_address:1 They all returned the following: VNC Viewer Free Edition 4.1.1 for X - built Apr 9 2010 18:41:55 Copyright (C) 2002-2005 RealVNC Ltd. See http ://www .realvnc. com for information on VNC. vncviewer: unable to open display "" I'm sure I'm missing something important, but I'm not sure what it is. Do I need to have a GUI installed, or did that come with the vnc packages I installed?

    Read the article

  • Dell Management Packs in System Center Operations Manager 2007 R2?

    - by bwerks
    Hey all, I recently set up SCOM in a small business network environment. The root management server is a Dell Poweredge 2950, and I'd like to use SCOM to monitor it using Dell's management packs. I've imported the management packs into the SCOM deployment and followed Dell's installation instructions, but it doesn't seem to be fully working yet. Currently, the Diagram views in the Dell tree (Monitoring tab) seem to show me the server's place in the network topology, so it seems that at least part of it is working. However, none of the reports under "Performance and Power Monitoring Views" provide any information. When clicking on one of them (Power Consumption (Watts), for instance), the display area is blank and there is a tooltip visible that reads "No performance counter is selected. To select a counter, place a check mark in the Show column in legend below." However, in the legend, there's nothing there for me to check. I've installed OpenManage 6.2 on the server as per the Dell documentation, but I don't know what else I could have done that I missed. Does this sound like a familiar problem to anyone?

    Read the article

  • System Information (msinfo32.exe) Can't Collect Information

    - by ptanne
    I have Windows XP Pro, service pack 1, IE 6 and 32GB of free space, 75GB total. I have had nothing but trouble after trying to install service pack 2 even though I used System Restore. The installation was incomplete and my computer has never been the same. I attempted to install sp2 four or five times and sp3 once, always with the same result. I've tried reinstalling XP Pro but that didn't fix the problem. My XP Pro disk now has a scratch on it and refuses to work. Dell would not replace it stating that my computer was out of warranty. I'm currently trying Reimage which is supposed to return a computer to the original configuration and replace missing or damaged files. Believe it or not, Ripley, it stops in the middle of the operation and, so far, the Reimage techs haven't been able to figure out why. Of the many problems that I still have is that System Information can't collect information. The Help and Support sections that display system info also don't work. Is there some way that I can fix this? I can't afford to throw my computer away, yet. Thank you for listening, Pam Galvin

    Read the article

  • X11 performance problem after upgrading from Centos3 to Centos5 with an ATI Rage XL

    - by Marcelo Santos
    After upgrading a computer from Centos3 to Centos5 an application that does a lot of scrolling took a very high performance hit. top tells me that X is using a lot of CPU and that was not happening before. The machine has an ATI Rage XL with 8MB and X is using the ati driver as there is no proprietary ATI driver for this board on linux. The xorg.conf: Section "Device" Identifier "Videocard0" Driver "ati" EndSection Section "Screen" Identifier "Screen0" Device "Videocard0" DefaultDepth 24 SubSection "Display" Viewport 0 0 Depth 24 Modes "1024x768" "800x600" "640x480" EndSubSection EndSection Section "DRI" Group 0 Mode 0666 EndSection A similar machine that still has Centos3 installed is able to start DRI on the X server while this one is not, this is the Xorg.0.log for the Centos5 machine: drmOpenDevice: node name is /dev/dri/card0 drmOpenDevice: open result is -1, (No such device or address) drmOpenDevice: open result is -1, (No such device or address) drmOpenDevice: Open failed drmOpenDevice: node name is /dev/dri/card0 drmOpenDevice: open result is -1, (No such device or address) drmOpenDevice: open result is -1, (No such device or address) drmOpenDevice: Open failed [drm] failed to load kernel module "mach64" (II) ATI(0): [drm] drmOpen failed (EE) ATI(0): [dri] DRIScreenInit Failed (II) ATI(0): Largest offscreen areas (with overlaps): (II) ATI(0): 1024 x 1279 rectangle at 0,768 (II) ATI(0): 768 x 1280 rectangle at 0,768 (II) ATI(0): Using XFree86 Acceleration Architecture (XAA) Screen to screen bit blits Solid filled rectangles 8x8 mono pattern filled rectangles Indirect CPU to Screen color expansion Solid Lines Offscreen Pixmaps Setting up tile and stipple cache: 32 128x128 slots 10 256x256 slots (==) ATI(0): Backing store disabled (==) ATI(0): Silken mouse enabled (II) ATI(0): Direct rendering disabled (==) RandR enabled I also tried using EXA instead of XAA and setting: Option "AccelMethod" "XAA" Option "XAANoOffscreenPixmaps" "true" uname -a Linux sir5.erg.inpe.br 2.6.18-128.7.1.el5 #1 SMP Mon Aug 24 08:20:55 EDT 2009 i686 i686 i386 GNU/Linux rpm -qa | grep xorg-x11-server xorg-x11-server-utils-7.1-4.fc6 xorg-x11-server-sdk-1.1.1-48.52.el5 xorg-x11-server-Xvfb-1.1.1-48.52.el5 xorg-x11-server-Xnest-1.1.1-48.52.el5 xorg-x11-server-Xorg-1.1.1-48.52.el5 The drmOpenDevice error continues when using the suggested Option "AIGLX" "true".

    Read the article

  • How can I make my PCI-E graphics card visible to Ubuntu when the motherboard has integrated graphics

    - by Norman Ramsey
    I have a Gigabyte GA-MA74GM-S2 motherboard with integrated graphics that shows up on lspci as an ATI Radeon 2100. I also bought a PCI-Express Nvidia graphics card so I could use the VDPAU feature on Linux (plays H.264 in hardware). The BIOS has three settings about which display to initialize first: Integrated graphics PCI graphics PCI-Express graphics (PEG) I set the BIOS on PEG, but I cannot get anything, not even a splash screen or POST messages, to emerge from the PCI-Express graphics card. (I'm using a DVI connector; the card also has an HDMI output.) I cannot get the kernel lspci to see the graphics card; the only VGA controller it acknowledges is the integrated one. Running dmidecode acknowledges the existence of an x16 PCI Express slot, and it says Current usage: Unknown There is an additional BIOS setting called "Internal Graphics Mode" which is normally set to "Auto" which means it is supposed to prefer a PCI Express VGA card. I set it to "Disabled" which now means I'm getting no output at all. I will soon be learning how to do a BIOS reset! Other information: The PCI-E card is a MSI N210-MD512H GeForce 210. This is a fanless card. Although there are no fans to see turning, the heat sink on the PCI-E card is definitely getting hot, so the card is getting some sort of power. It gets all its power from the PCI-E slot; there is no external power connector. The BIOS is an AMI Award BIOS. My question: how can I make the PCI Express graphics card visible to Ubuntu?

    Read the article

  • Open Source PDF reader for windows as an alternative to Adobe reader

    - by Tom Feiner
    With the latest javascript vulnerabilities in Adobe reader and bloat it has aquired over the years, I've been thinking of moving the network I'm in charge of to a different product for PDF reading on Windows. The ideal PDF reader should be something that is: Small in size (Adobe reader is more than 200MB these days after installation). As secure by default as possible (For example, javascript disabled by default). Nice looking and easy to use interface. Not bloated with features (I just want to read PDFs, that's it). Does not install any toolbars/unwanted add ons/spyware. Does not display any ads while viewing PDFs. Preferably Open Source. (this pretty much ensures no ads). Full Unicode support. Idealy , something like evince from gnome, will be the best option, but unfortunately that's not available on Windows. Foxit is an option, as it is small, and has a nice interface. But it still has javascript enabled by default which might lead to vulnerabilities - and it installs a toolbar , and displays ads while reading PDFs which is distracting. There is a site dedicated to Open Source PDF readers, pdfreaders.org, however, the Windows pdf readers each have their problems, mostly the interface is not as convenient (as evince, adobe or foxit). Here's a list of all PDF software from WikiPedia. There's a "Viewers" section for each OS. What Windows PDF reader would you recommend ?

    Read the article

  • IIS6.0 asking for credentials after MS Updates

    - by Adam M.
    We have an IIS6.0 Server running on a Windows 2003 Server. Last weekend it went though maintenance, and updated a quite a few Windows updates, it is now brought up to current updates (as of March 29th). Previous to these updates we could connect to the Web page via the hostname or via a alias (there is a DNS and a WINS alias (the alias is the same name in both) that are both pointing to the system). Now since the updates it asks for credentials to access the page, when trying to access the page via IP, or by name. If you use the alias it will go right into the page. I had added a new alias in DNS and tried to access it via this name with the same effect. So it appears that the WINS alias allows the page to show up properly. I have seen this KB but http://support.microsoft.com/kb/871179 though not sure if it really is relevant to this issue. As it does refer to the 3 strikes rules to display the 401.1 error. The IIS Application pool is running under a domain account. Teh default page is allowing Anonymous login under a local account. Any thoughts? Thanks Adam

    Read the article

  • MacBook Pro battery capacity 65K mAh

    - by Alexander Gladysh
    I have a 15" MacBook Pro 3.1 (that is Late 2007 model AFAIR). I've bought it new a couple of years ago. Recently its on-battery power lifespan became very short (30 to 10 minutes). When my notebook turns itself off due to "low battery" and I press the small button on the battery itself, all LED lights are alight, indicating full charge. When I plug in the power adapter, my Mac displays that "battery is fully charged, finishing charging process" (I have a Russian OS X 10.5.7, so that is a rough translation), but the LEDs on battery itself display (seemingly accurate) status that there are one or two "LEDs still not charged". My battery have as few as 37 recharge cycles (yes, I've neglected calibration over the time I've used it). Battery info programs like iBatt2 report battery capacity of 65 337 mAh (with by-design capacity of 5600 mAh). I get it that something went wrong with battery electronics. I've tried resetting my Mac's PRAM and SMC, it did not changed anything. Now I'm trying to recalibrate the battery, but looks like it does not help as well. Will try to recalibrate it several times in a row. I'd buy a new battery if I knew if it is battery fault, not a notebook's. Any suggestions? Update: After recalibration, my battery status now displays battery capacity of 1500 mAh. But with every recalibration (or simply when I use notebook without power adapter plugged in) this number changes in the range from 200 mAh to 1700 mAh. LEDs on battery now are synchronous with what nodebook thinks on the charge level. Also I've noticed that cycle count changes rather slowly. It is now 39, it was 37 when I've started recalibration, and I went through the process at least ten times... So, the main question is: does it look like that replacing the battery would help me (or does it look like this is notebook's problem)? I guess I should try replacing the battery.

    Read the article

  • get-eventlog issue

    - by Jim B
    I wanted to get a quick report of some log entries I saw on a server, so I ran: Get-Eventlog -logname system -newest 10 -computer fs1 | fl I got events back however the descriptions were all wrong. Here's an example: Index : 1260055 EntryType : Warning InstanceId : 2186936367 Message : The description for Event ID '-2108030929' in Source 'W32Time' cannot be found. The local compute r may not have the necessary registry information or message DLL files to display the message, or you may not have permission to access them. The following information is part of the event:'time. windows.com,0x1' Category : (0) CategoryNumber : 0 ReplacementStrings : {time.windows.com,0x1} Source : W32Time TimeGenerated : 1/25/2010 10:43:31 AM TimeWritten : 1/25/2010 10:43:31 AM UserName : Note that if I pull the event ID property it's correct (in this case 38) Is this is known issue or is something wrong. The messages resolve fine via event viewer locally and remotely Here is the powershell version info: Name : ConsoleHost Version : 2.0 InstanceId : bc58fcf8-bba3-4ca8-8972-17dbd5d9ff08 UI : System.Management.Automation.Internal.Host.InternalHostUserInterface CurrentCulture : en-US CurrentUICulture : en-US PrivateData : Microsoft.PowerShell.ConsoleHost+ConsoleColorProxy IsRunspacePushed : False Runspace : System.Management.Automation.Runspaces.LocalRunspace Here is the revised version info: Name Value ---- ----- CLRVersion 2.0.50727.3603 BuildVersion 6.0.6002.18111 PSVersion 2.0 WSManStackVersion 2.0 PSCompatibleVersions {1.0, 2.0} SerializationVersion 1.1.0.1 PSRemotingProtocolVersion 2.1

    Read the article

  • Why apache doesn't restart after configuring SSL?

    - by poz2k4444
    I've installed apache2 and then configure it to work with SSL following this and this tutorials, the problem becomes when I try to restart the service, the following error throws: (98)Address already in use: make_sock: could not bind to address 0.0.0.0:443 no listening sockets available, shutting down Unable to open logs the output of netstat -anp | grep 443 just display firefox listening and anything else, how could I solve this and get the service running?? The ouput of ps -Af|grep <firefox PID> is: root 1949 1 11 18:42 tty1 00:20:55 /opt/firefox/firefox-bin root 2025 1949 4 18:43 tty1 00:08:39 /opt/firefox/plugin-container /root/.mozilla/plugins/libflashplayer.so -greomni /opt/firefox/omni.ja 1949 true plugin after closing firefox and then cheking again for port 443 the output is: tcp 0 0 10.32.208.179:38923 74.125.139.155:443 TIME_WAIT - tcp 0 0 10.32.208.179:45706 74.125.139.113:443 TIME_WAIT - tcp 0 0 10.32.208.179:40456 74.125.139.156:443 TIME_WAIT - tcp 0 0 10.32.208.179:56823 69.171.227.62:443 FIN_WAIT2 - unix 3 [ ] STREAM CONNECTED 12443 1721/dbus-daemon @/tmp/dbus-8ee35rmOOS Seeing the error logs, which are not at the time when I'm doing this, the last errors are: [Tue Oct 02 18:41:54 2012] [error] Init: Unable to read server certificate from file /etc/apache2/ssl/sever.crt [Tue Oct 02 18:41:54 2012] [error] SSL Library Error: 218529960 error:0D0680A8:asn1 encoding routines:ASN1_CHECK_TLEN:wrong tag [Tue Oct 02 18:41:54 2012] [error] SSL Library Error: 218595386 error:0D07803A:asn1 encoding routines:ASN1_ITEM_EX_D2I:nested asn1 error

    Read the article

  • IIS URL Rewrite HTTP to HTTPS with Port

    - by Andy Arismendi
    My website has two bindings: 1000 and 1443 (port 80/443 are in use by another website on the same IIS instance). Port 1000 is HTTP, port 1443 is HTTPS. What I want to do is redirect any incoming request using "htt p://server:1000" to "htt ps://server:1443". I'm playing around with IIS 7 rewrite module 2.0 but I'm banging my head against the wall. Any insight is appreciated! BTW the rewrite configuration below works great with a site that has an HTTP binding on port 80 and HTTPS binding on port 443, but it doesn't work with my ports. P.S. My URLs intentionally have spaces because the 'spam prevention mechanism' kicked in. For some reason google login doesn't work anymore so I had to create an OpenID account (No Script could be the culprit). I'm not sure how to get XML to display nicely so I added spaces after the opening brackets. < ?xml version="1.0" encoding="utf-8"? < configuration < system.webServer < rewrite < rules < rule name="HTTP to HTTPS redirect" stopProcessing="true" < match url="(.*)" / < conditions trackAllCaptures="true" < add input="{HTTPS}" pattern="off" / < /conditions < action type="Redirect" redirectType="Found" url="htt ps: // {HTTP_HOST}/{R:1}" / < /rule < /rules < /rewrite < /system.webServer < /configuration

    Read the article

  • Preventing access to files if a user types the full url on the address bar

    - by bogha
    i have a website, some folders on the websites contains images and files like .pdf , .doc and .docx . the user can easly just type the address in the url to get the file or display the photo http://site/folder1/img/pic1.jpg then boom.. he can see the image or just download the file my question is: how to prevent this kind of action, how can i guarantee a secure access of the files. any suggestions UPDATE TO CLARIFY MY IDEA i don't want any user who is browsing the website to get access to these files normally by just writing the URL of the file. those files are a CV files, they are being uploaded by the users to a specific folder on the server which we host outside the company. those files are only being viewed by the HR people through a special system. that's the scenario we want. i don't want a WEB GEEK who just wants to see what files has been uploaded to this folder to download them easly to his/her computer and view them or publish them on the internet. i hope you got my idea

    Read the article

  • Cannot connect to local network shares when connected to VPN. Error: "the user name could not be found"

    - by Nick G
    I keep finding that on our small company LAN (7 users, 3 servers) that some servers keep becoming "not accessible" for the purposes of file sharing. They display the message "\SERVER is not accessible. You might not have permission to use this network resource. The user name could not be found". But I don't know why "the user name could not be found" as all the machines are on the same domain and the PDC and BDC seem to be behaving OK. EDIT: VPN seems to be the cause: It turns out I can see the server if I use the IP address (\\1.2.3.4\ etc) or the FQ active directory name (eg \server.domainname.local) but not if I use the server name on its own or a mapped network drive originally created from the "short" name. Oddly though, my machine has no issue resolving the server's DNS name as I can ping the machine name OK and it immediately comes back with the IP, however nslookup seems to fail. It seems to be a problem with how Windows looks up machine names when connected to VPNs. When I'm connected to a VPN, windows seems to use the DNS assocated with the VPN and not the one on the domain controller. This behavior to me, seems incorrect as surely that would mean connecting to any VPN would break any ability to lookup local machine names for servers and printers etc. So I guess the real question now is, how can I make my machine still search the local Active Directory DNS (the PDC) even when connected to a VPN? More info in my comments below.

    Read the article

  • What's up with stat on MacOSX/Darwin? Or filesystems without names...

    - by Charles Stewart
    In response to a question I asked on SO, Give the mount point of a path, one respondant suggested using stat to get the device name associated with the volume of a given path. This works nicely on Linux, but gives crazy results on MacOSX 10.4. For my system, df and mount give: cas cas$ df Filesystem 512-blocks Used Avail Capacity Mounted on /dev/disk0s3 58342896 49924456 7906440 86% / devfs 194 194 0 100% /dev fdesc 2 2 0 100% /dev <volfs> 1024 1024 0 100% /.vol automount -nsl [166] 0 0 0 100% /Network automount -fstab [170] 0 0 0 100% /automount/Servers automount -static [170] 0 0 0 100% /automount/static /dev/disk2s1 163577856 23225520 140352336 14% /Volumes/Snapshot /dev/disk2s2 409404102 5745938 383187960 1% /Volumes/Sparse cas cas$ mount /dev/disk0s3 on / (local, journaled) devfs on /dev (local) fdesc on /dev (union) <volfs> on /.vol automount -nsl [166] on /Network (automounted) automount -fstab [170] on /automount/Servers (automounted) automount -static [170] on /automount/static (automounted) /dev/disk2s1 on /Volumes/Snapshot (local, nodev, nosuid, journaled) /dev/disk2s2 on /Volumes/Sparse (asynchronous, local, nodev, nosuid) Trying to get the devices from the mount points, though: cas cas$ df | grep -e/ | awk '{print $NF}' | while read line; do echo $line $(stat -f"%Sdr" $line); done / disk0s3r /dev ???r /dev ???r /.vol ???r /Network ???r /automount/Servers ???r /automount/static ???r /Volumes/Snapshot disk2s1r /Volumes/Sparse disk2s2r Here, I'm feeding each of the mount points scraped from df to stat, outputting the results of the "%Sdr" format string, which is supposed to be the device name: Cf. stat(1) man page: The special output specifier S may be used to indicate that the output, if applicable, should be in string format. May be used in combination with: ... dr Display actual device name. What's going on? Is it a bug in stat, or some Darwin VFS weirdness? Postscript Per Andrew McGregor, try passing "%Sd" to stat for more weirdness. It lists some apparently arbitrary subset of files from CWD...

    Read the article

  • mod_rewrite: redirect from subdomain to main domain

    - by Bald
    I have two domains - domain.com and forum.domain.com that points to the same directory. I'd like redirect all request from forum.domain.com to domain.com (for example: forum.domain.com/foo to domain.com/forum/foo) without changing address in addres bar (hidden redirect). I wrote something like this and put it into .htaccess file: Options +FollowSymlinks RewriteEngine on RewriteCond %{HTTP_HOST} ^forum\.example\.net$ RewriteRule (.*) http://example.com/forum/$1 [L] RewriteCond %{REQUEST_FILENAME} !-s [NC] RewriteCond %{REQUEST_FILENAME} !-d [NC] RewriteRule ^(.+) index.php/$1 [L] That works only if I add Redirect directive: RewriteRule (.*) http://example.com/forum/$1 [R,L] But it changes previous address in address bar. EDIT: Ok, let's make it simple. I added those two lines at the end of the c:\windows\system32\drivers\etc\hosts on my local computer: 127.0.0.3 foo.net 127.0.0.3 forum.foo.net Now, I created two virtual hosts: <VirtualHost foo.net:80> ServerAdmin [email protected] ServerName foo.net DocumentRoot "C:/usr/src/foo" </VirtualHost> <VirtualHost forum.foo.net:80> ServerAdmin [email protected] ServerName forum.foo.net DocumentRoot "C:/usr/src/foo" </VirtualHost> ..and directory called "foo", where i put two files: .htaccess and index.php. Index.php: <?php echo $_SERVER['PATH_INFO']; ?> .htaccess: Options +FollowSymlinks RewriteEngine on RewriteBase / RewriteCond %{HTTP_HOST} ^forum\.foo\.net$ RewriteCond %{REQUEST_URI} !^/forum/ RewriteCond %{REQUEST_FILENAME} !-s [NC] RewriteCond %{REQUEST_FILENAME} !-d [NC] RewriteRule ^(.+)$ /index.php/forum/$1 [L] RewriteCond %{HTTP_HOST} !^forum\.foo\.net$ RewriteCond %{REQUEST_FILENAME} !-s [NC] RewriteCond %{REQUEST_FILENAME} !-d [NC] RewriteRule ^(.+) index.php/$1 [L] When I type address http://forum.foo.net/test in address bar, it displays /forum/test which is good. http://foo.net/a/b/c shows /a/b/c which is good. But! http://forum.foo.net/ displays empty value (should display /forum).

    Read the article

  • How can I calculate power consumption of my PC in Watt?

    - by Jitendra vyas
    How can I calculate power consumption of my PC in Watt, to prove my House owner ( I live on rent) , my PC doesn't consume much power? He blames me for Huge power bills even he too use Fridge, A.C. etc and his son watch the TV all the time. We both share one Power meter so for bill we pay 50%-50% but He is saying I use PC all the time even night i keep on for downloading. I just want to calculate power consumption of my PC then will calculate monthly expense of unit as per my City's per unit price for power. I've Windows: Microsoft Windows XP Professional 5.1.2600 Service Pack 3 Memory (RAM): 960 MB CPU Info: AMD Sempron(tm) Processor 2500+ CPU Speed: 1399.0 MHz Sound card: Vinyl AC'97 Audio (WAVE) Display Adapters: VIA/S3G UniChrome Pro IGP | NetMeeting driver | RDPDD Chained DD Monitors: 1 - 17inch LCD - LG Screen Resolution: 1280 X 768 - 32 bit Network: Network Present Network Adapters: Bluetooth Device (Personal Area Network) #2 | WAN (PPP/SLIP) Interface CD / DVD Drives: I: ELBY CLONEDRIVE COM Ports: COM1 | COM2 | COM7 | COM8 | COM9 | COM10 LPT Ports: LPT1 Mouse: 3 Button Wheel Mouse Present Hard Disks: C: 29.3GB | D: 29.3GB | E: 97.7GB | F: 97.7GB | G: 211.9GB USB Controllers: 5 host controllers. Firewire (1394): 1 host controllers. Manufacturer: Phoenix Technologies, LTD Product Make: MS-7142 AC Power Status: OnLine BIOS Info: AT/AT COMPATIBLE | 01/18/06 | VIAK8M - 42302e31 Motherboard: MICRO-STAR INTERNATIONAL CO., LTD MS-7142 Modem: ZTE USB Modem FFFE CDMA #2

    Read the article

  • Problem setting command-line console resolution. vbeinfo in grub2 does not report all resolutions

    - by Kent
    I have a Asus EEE PC 1005P which I installed a Command-line system on using the Alternate Installer CD of Ubuntu Lucid Lynx. Altough I think this is a general linux and grub2 question. I do not have (or want) the X Window System installed. I want to change my console screen resolution (not inside X) to 1024x600. But it isn't reported when I use vbeinfo inside grub: grub> vbeinfo VBE info: version: 3.0 OEM software rev: 1.0 total memory: 8128 KiB List of compatible video modes: Legend: P=Packed pixel, D=Direct color, mask/pos=R/G/B/reserved 0x112: 640 x 480 x 32 Direct, mask: 8/8/8/8 pos: 16/8/0/24 0x114: 800 x 600 x 16 Direct, mask: 5/6/5/0 pos: 11/5/0/0 0x115: 800 x 600 x 32 Direct, mask: 8/8/8/8 pos: 16/8/0/24 0x101: 640 x 480 x 8 Packed 0x103: 800 x 600 x 8 Packed 0x111: 640 x 480 x 16 Direct, mask: 5/6/5/0 pos: 11/5/0/0 Configured VBE mode (vbe_mode) = ox101 grub> Relevant parts of sudo lspci -v: ... ... 00:02.0 VGA compatible controller: Intel Corporation N10 Family Integrated Graphics Controller Subsystem: ASUSTeK Computer Inc. Device 83ac Flags: bus master, fast devsel, latency 0, IRQ 28 ... Kernel driver in use: i915 Kernel modules: i915 00:02.1 Display controller: Intel Corporation N10 Family Integrated Graphics Controller Subsystem: ASUSTeK Computer Inc. Device 83ac Flags: bus master, fast devsel, latency 0, IRQ 28 ... ... ... Any ideas on how I can set the console resultion like I want it?

    Read the article

  • some PDF's to iPhones via ActiveSync are corrupt

    - by longneck
    we have two server applications (one .NET/ASP web app, the other a native Windows app) that generate PDF's that are then emailed to our users on Exchange 2010. the apps deliver the emails to the Exchange server via SMTP, and our iPhone/iPad users receive their email via activesync. pretty much all of the PDF's generated by the web app and many of the PDF's generated by the Windows app fail to open on an iPhone or iPad. tapping the attachment shows the screen that would display the PDF with the name of the file at the top but the bottom of the screen is completely grey. one thing i have figured out is that the attachment on the iPad is uuencoded. forwarding the attachment to another email address shows the uuencoded format. here's a sample: begin 600 unknown M)5!$1BTQ+C0-)>+CS],-"C8@,"!O8FH\/"](6S8U-B`Q-#A=+TQI;F5A<FEZ M960@,2]%(#DQ-#8O3"`Q,S`Q.2].(#$O3R`Y+U0@,3(X-3,^/@UE;F1O8FH- ---snip--- M,C8T,"`P,#`P,"!N#0IT<F%I;&5R#0H\/"]3:7IE(#8^/@T*<W1A<G1X<F5F .#0HQ,38-"B4E14]&#0H` ` end whereas the normal version of the file looks like a normal PDF: %PDF-1.4 %âãÏÓ 6 0 obj<</H[656 147]/Linearized 1/E 9698/L 13571/N 1/O 9/T 13405>> ---snip--- trailer <</Size 6>> startxref 116 %%EOF so i think the problem is that the attachment is being double uuencoded somewhere, or the iPhone is failing to recognize that the attachment is uuencoded and not decoding it. any suggestions on where to begin troubleshooting this problem?

    Read the article

< Previous Page | 568 569 570 571 572 573 574 575 576 577 578 579  | Next Page >