Search Results

Search found 23131 results on 926 pages for 'ms query'.

Page 583/926 | < Previous Page | 579 580 581 582 583 584 585 586 587 588 589 590  | Next Page >

  • Difference between LASTDATE and MAX for semi-additive measures in #DAX

    - by Marco Russo (SQLBI)
    I recently wrote an article on SQLBI about the semi-additive measures in DAX. I included the formulas common calculations and there is an interesting point that worth a longer digression: the difference between LASTDATE and MAX (which is similar to FIRSTDATE and MIN – I just describe the former, for the latter just replace the correspondent names). LASTDATE is a dax function that receives an argument that has to be a date column and returns the last date active in the current filter context. Apparently, it is the same value returned by MAX, which returns the maximum value of the argument in the current filter context. Of course, MAX can receive any numeric type (including date), whereas LASTDATE only accepts a column of type date. But overall, they seems identical in the result. However, the difference is a semantic one. In fact, this expression: LASTDATE ( 'Date'[Date] ) could be also rewritten as: FILTER ( VALUES ( 'Date'[Date] ), 'Date'[Date] = MAX ( 'Date'[Date] ) ) LASTDATE is a function that returns a table with a single column and one row, whereas MAX returns a scalar value. In DAX, any expression with one row and one column can be automatically converted into the corresponding scalar value of the single cell returned. The opposite is not true. So you can use LASTDATE in any expression where a table or a scalar is required, but MAX can be used only where a scalar expression is expected. Since LASTDATE returns a table, you can use it in any expression that expects a table as an argument, such as COUNTROWS. In fact, you can write this expression: COUNTROWS ( LASTDATE ( 'Date'[Date] ) ) which will always return 1 or BLANK (if there are no dates active in the current filter context). You cannot pass MAX as an argument of COUNTROWS. You can pass to LASTDATE a reference to a column or any table expression that returns a column. The following two syntaxes are semantically identical: LASTDATE ( 'Date'[Date] ) LASTDATE ( VALUES ( 'Date'[Date] ) ) The result is the same and the use of VALUES is not required because it is implicit in the first syntax, unless you have a row context active. In that case, be careful that using in a row context the LASTDATE function with a direct column reference will produce a context transition (the row context is transformed into a filter context) that hides the external filter context, whereas using VALUES in the argument preserve the existing filter context without applying the context transition of the row context (see the columns LastDate and Values in the following query and result). You can use any other table expressions (including a FILTER) as LASTDATE argument. For example, the following expression will always return the last date available in the Date table, regardless of the current filter context: LASTDATE ( ALL ( 'Date'[Date] ) ) The following query recap the result produced by the different syntaxes described. EVALUATE     CALCULATETABLE(         ADDCOLUMNS(              VALUES ('Date'[Date] ),             "LastDate", LASTDATE( 'Date'[Date] ),             "Values", LASTDATE( VALUES ( 'Date'[Date] ) ),             "Filter", LASTDATE( FILTER ( VALUES ( 'Date'[Date] ), 'Date'[Date] = MAX ( 'Date'[Date] ) ) ),             "All", LASTDATE( ALL ( 'Date'[Date] ) ),             "Max", MAX( 'Date'[Date] )         ),         'Date'[Calendar Year] = 2008     ) ORDER BY 'Date'[Date] The LastDate columns repeat the current date, because the context transition happens within the ADDCOLUMNS. The Values column preserve the existing filter context from being replaced by the context transition, so the result corresponds to the last day in year 2008 (which is filtered in the external CALCULATETABLE). The Filter column works like the Values one, even if we use the FILTER instead of the LASTDATE approach. The All column shows the result of LASTDATE ( ALL ( ‘Date’[Date] ) ) that ignores the filter on Calendar Year (in fact the date returned is in year 2010). Finally, the Max column shows the result of the MAX formula, which is the easiest to use and only don’t return a table if you need it (like in a filter argument of CALCULATE or CALCULATETABLE, where using LASTDATE is shorter). I know that using LASTDATE in complex expressions might create some issue. In my experience, the fact that a context transition happens automatically in presence of a row context is the main reason of confusion and unexpected results in DAX formulas using this function. For a reference of DAX formulas using MAX and LASTDATE, read my article about semi-additive measures in DAX.

    Read the article

  • Tweaking a few URL validation settings on ASP.NET v4.0

    - by Carlyle Dacosta
    ASP.NET has a few default settings for URLs out of the box. These can be configured quite easily in the web.config file within the  <system.web>/<httpRuntime> configuration section. Some of these are: <httpRuntime maxUrlLength=”<number here>”. This number should be an integer value (defaults to 260 characters). The value must be greater than or equal to zero, though obviously small values will lead to an un-useable website. This attribute gates the length of the Url without query string. <httpRuntime maxQueryStringLength=”<number here>”. This number should be an integer value (defaults to 2048 characters). The value must be greater than or equal to zero, though obviously small values will lead to an un-useable website. <httpRuntime requestPathInvalidCharacters=”List of characters you need included in ASP.NETs validation checks”. By default the characters are “<,>,*,%,&,:,\,?”. However once can easily change this by setting by modifying web.config. Remember, these characters can be specified in a variety of formats. For example, I want the character ‘!’ to be included in ASP.NETs URL validation logic. So I set the following: <httpRuntime requestPathInvalidCharacters=”<,>,*,%,&,:,\,?,!”. A character could also be specified in its xml encoded form. ‘&lt;;’ would mean the ‘<’ sign). I could specify the ‘!’ in its xml encoded unicode format such as requestPathInvalidCharacters=”<,>,*,%,&,:,\,?,$#x0021;” or I could specify it in its unicode encoded form or in the “<,>,*,%,&,:,\,?,%u0021” format. The following settings can be applied at Root Web.Config level, App Web.config level, Folder level or within a location tag: <location path="some path here"> <system.web> <httpRuntime maxUrlLength="" maxQueryStringLength="" requestPathInvalidChars="" .csharpcode, .csharpcode pre { font-size: small; color: black; font-family: consolas, "Courier New", courier, monospace; background-color: #ffffff; /*white-space: pre;*/ } .csharpcode pre { margin: 0em; } .csharpcode .rem { color: #008000; } .csharpcode .kwrd { color: #0000ff; } .csharpcode .str { color: #006080; } .csharpcode .op { color: #0000c0; } .csharpcode .preproc { color: #cc6633; } .csharpcode .asp { background-color: #ffff00; } .csharpcode .html { color: #800000; } .csharpcode .attr { color: #ff0000; } .csharpcode .alt { background-color: #f4f4f4; width: 100%; margin: 0em; } .csharpcode .lnum { color: #606060; } If any of the above settings fail request validation, an Http 400 “Bad Request” HttpException is thrown. These can be easily handled on the Application_Error handler on Global.asax.   Also, a new attribute in <httpRuntime /> called “relaxedUrlToFileSystemMapping” has been added with a default of false. <httpRuntime … relaxedUrlToFileSystemMapping="true|false" /> When the relaxedUrlToFileSystemMapping attribute is set to false inbound Urls still need to be valid NTFS file paths. For example Urls (sans query string) need to be less than 260 characters; no path segment within a Url can use old-style DOS device names (LPT1, COM1, etc…); Urls must be valid Windows file paths. A url like “http://digg.com/http://cnn.com” should work with this attribute set to true (of course a few characters will need to be unblocked by removing them from requestPathInvalidCharacters="" above). Managed configuration for non-NTFS-compliant Urls is determined from the first valid configuration path found when walking up the path segments of the Url. For example, if the request Url is "/foo/bar/baz/<blah>data</blah>", and there is a web.config in the "/foo/bar" directory, then the managed configuration for the request comes from merging the configuration hierarchy to include the web.config from "/foo/bar". The value of the public property HttpRequest.PhysicalPath is set to [physical file path of the application root] + "REQUEST_URL_IS_NOT_A_VALID_FILESYSTEM_PATH". For example, given a request Url like "/foo/bar/baz/<blah>data</blah>", where the application root is "/foo/bar" and the physical file path for that root is "c:\inetpub\wwwroot\foo\bar", then PhysicalPath would be "c:\inetpub\wwwroot\foo\bar\ REQUEST_URL_IS_NOT_A_VALID_FILESYSTEM_PATH". Carl Dacosta ASP.NET QA Team

    Read the article

  • Creating ground in a 2D runner game

    - by user739711
    It may be a repetitive uestion but I could not find any specific answer to my query How to create A slanted/curved ground in a 2d runner game. The user will see side view like the old game "Mario" If I use tiled based map I can have only rectangular objects. What is the best way to create tilted ground? Should I use tiled based map, or should I define corner points in the map and create the ground programatically? And what are the difficulties in creating curved ground.

    Read the article

  • Comparing LINQ to SQL vs the classic SqlCommand

    tweetmeme_url = 'http://alpascual.com/blog/comparing-linq-to-sql-vs-the-classic-sqlcommand/';tweetmeme_source = 'alpascual';When you are coming from using SqlCommand and SqlConnection is difficult to move to another library for your database needs. For those people still in the limbo to make the decision to move to another DAL, here is a comparison to help you see the light or to move away for ever.   How to do a select query using SqlCommand: 1: SqlConnection myConnection = new...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Comparing LINQ to SQL vs the classic SqlCommand

    tweetmeme_url = 'http://alpascual.com/blog/comparing-linq-to-sql-vs-the-classic-sqlcommand/';tweetmeme_source = 'alpascual';When you are coming from using SqlCommand and SqlConnection is difficult to move to another library for your database needs. For those people still in the limbo to make the decision to move to another DAL, here is a comparison to help you see the light or to move away for ever.   How to do a select query using SqlCommand: 1: SqlConnection myConnection = new...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Troubleshooting Application Timeouts in SQL Server

    - by Tara Kizer
    I recently received the following email from a blog reader: "We are having an OLTP database instance, using SQL Server 2005 with little to moderate traffic (10-20 requests/min). There are also bulk imports that occur at regular intervals in this DB and the import duration ranges between 10secs to 1 min, depending on the data size. Intermittently (2-3 times in a week), we face an issue, where queries get timed out (default of 30 secs set in application). On analyzing, we found two stored procedures, having queries with multiple table joins inside them of taking a long time (5-10 mins) in getting executed, when ideally the execution duration ranges between 5-10 secs. Execution plan of the same displayed Clustered Index Scan happening instead of Clustered Index Seek. All required Indexes are found to be present and Index fragmentation is also minimal as we Rebuild Indexes regularly alongwith Updating Statistics. With no other alternate options occuring to us, we restarted SQL server and thereafter the performance was back on track. But sometimes it was still giving timeout errors for some hits and so we also restarted IIS and that stopped the problem as of now." Rather than respond directly to the blog reader, I thought it would be more interesting to share my thoughts on this issue in a blog. There are a few things that I can think of that could cause abnormal timeouts: Blocking Bad plan in cache Outdated statistics Hardware bottleneck To determine if blocking is the issue, we can easily run sp_who/sp_who2 or a query directly on sysprocesses (select * from master..sysprocesses where blocking <> 0).  If blocking is present and consistent, then you'll need to determine whether or not to kill the parent blocking process.  Killing a process will cause the transaction to rollback, so you need to proceed with caution.  Killing the parent blocking process is only a temporary solution, so you'll need to do more thorough analysis to figure out why the blocking was present.  You should look into missing indexes and perhaps consider changing the database's isolation level to READ_COMMITTED_SNAPSHOT. The blog reader mentions that the execution plan shows a clustered index scan when a clustered index seek is normal for the stored procedure.  A clustered index scan might have been chosen either because that is what is in cache already or because of out of date statistics.  The blog reader mentions that bulk imports occur at regular intervals, so outdated statistics is definitely something that could cause this issue.  The blog reader may need to update statistics after imports are done if the imports are changing a lot of data (greater than 10%).  If the statistics are good, then the query optimizer might have chosen to scan rather than seek in a previous execution because the scan was determined to be less costly due to the value of an input parameter.  If this parameter value is rare, then its execution plan in cache is what we call a bad plan.  You want the best plan in cache for the most frequent parameter values.  If a bad plan is a recurring problem on your system, then you should consider rewriting the stored procedure.  You might want to break up the code into multiple stored procedures so that each can have a different execution plan in cache. To remove a bad plan from cache, you can recompile the stored procedure.  An alternative method is to run DBCC FREEPROCACHE which drops the procedure cache.  It is better to recompile stored procedures rather than dropping the procedure cache as dropping the procedure cache affects all plans in cache rather than just the ones that were bad, so there will be a temporary performance penalty until the plans are loaded into cache again. To determine if there is a hardware bottleneck occurring such as slow I/O or high CPU utilization, you will need to run Performance Monitor on the database server.  Hopefully you already have a baseline of the server so you know what is normal and what is not.  Be on the lookout for I/O requests taking longer than 12 milliseconds and CPU utilization over 90%.  The servers that I support typically are under 30% CPU utilization, but your baseline could be higher and be within a normal range. If restarting the SQL Server service fixes the problem, then the problem was most likely due to blocking or a bad plan in the procedure cache.  Rather than restarting the SQL Server service, which causes downtime, the blog reader should instead analyze the above mentioned things.  Proceed with caution when restarting the SQL Server service as all transactions that have not completed will be rolled back at startup.  This crash recovery process could take longer than normal if there was a long-running transaction running when the service was stopped.  Until the crash recovery process is completed on the database, it is unavailable to your applications. If restarting IIS fixes the problem, then the problem might not have been inside SQL Server.  Prior to taking this step, you should do analysis of the above mentioned things. If you can think of other reasons why the blog reader is facing this issue a few times a week, I'd love to hear your thoughts via a blog comment.

    Read the article

  • Tweaking a few URL validation settings on ASP.NET v4.0

    - by Carlyle Dacosta
    ASP.NET has a few default settings for URLs out of the box. These can be configured quite easily in the web.config file within the  <system.web>/<httpRuntime> configuration section. Some of these are: <httpRuntime maxUrlLength=”<number here>” This number should be an integer value (defaults to 260 characters). The value must be greater than or equal to zero, though obviously small values will lead to an un-useable website. This attribute gates the length of the Url without query string. <httpRuntime maxQueryStringLength=”<number here>”. This number should be an integer value (defaults to 2048 characters). The value must be greater than or equal to zero, though obviously small values will lead to an un-useable website. <httpRuntime requestPathInvalidCharacters=”List of characters you need included in ASP.NETs validation checks” /> By default the characters are “<,>,*,%,&,:,\,?”. However once can easily change this by setting by modifying web.config. Remember, these characters can be specified in a variety of formats. For example, I want the character ‘!’ to be included in ASP.NETs URL validation logic. So I set the following: <httpRuntime requestPathInvalidCharacters=”<,>,*,%,&,:,\,?,!”. A character could also be specified in its xml encoded form. ‘&lt;;’ would mean the ‘<’ sign). I could specify the ‘!’ in its xml encoded unicode format such as requestPathInvalidCharacters=”<,>,*,%,&,:,\,?,$#x0021;” or I could specify it in its unicode encoded form or in the “<,>,*,%,&,:,\,?,%u0021” format. The following settings can be applied at Root Web.Config level, App Web.config level, Folder level or within a location tag: <location path="some path here"> <system.web> <httpRuntime maxUrlLength="" maxQueryStringLength="" requestPathInvalidChars="" /> .csharpcode, .csharpcode pre { font-size: small; color: black; font-family: consolas, "Courier New", courier, monospace; background-color: #ffffff; /*white-space: pre;*/ } .csharpcode pre { margin: 0em; } .csharpcode .rem { color: #008000; } .csharpcode .kwrd { color: #0000ff; } .csharpcode .str { color: #006080; } .csharpcode .op { color: #0000c0; } .csharpcode .preproc { color: #cc6633; } .csharpcode .asp { background-color: #ffff00; } .csharpcode .html { color: #800000; } .csharpcode .attr { color: #ff0000; } .csharpcode .alt { background-color: #f4f4f4; width: 100%; margin: 0em; } .csharpcode .lnum { color: #606060; } If any of the above settings fail request validation, an Http 400 “Bad Request” HttpException is thrown. These can be easily handled on the Application_Error handler on Global.asax.   Also, a new attribute in <httpRuntime /> called “relaxedUrlToFileSystemMapping” has been added with a default of false. <httpRuntime … relaxedUrlToFileSystemMapping="true|false" /> When the relaxedUrlToFileSystemMapping attribute is set to false inbound Urls still need to be valid NTFS file paths. For example Urls (sans query string) need to be less than 260 characters; no path segment within a Url can use old-style DOS device names (LPT1, COM1, etc…); Urls must be valid Windows file paths. A url like “http://digg.com/http://cnn.com” should work with this attribute set to true (of course a few characters will need to be unblocked by removing them from requestPathInvalidCharacters="" above). Managed configuration for non-NTFS-compliant Urls is determined from the first valid configuration path found when walking up the path segments of the Url. For example, if the request Url is "/foo/bar/baz/<blah>data</blah>", and there is a web.config in the "/foo/bar" directory, then the managed configuration for the request comes from merging the configuration hierarchy to include the web.config from "/foo/bar". The value of the public property HttpRequest.PhysicalPath is set to [physical file path of the application root] + "REQUEST_URL_IS_NOT_A_VALID_FILESYSTEM_PATH". For example, given a request Url like "/foo/bar/baz/<blah>data</blah>", where the application root is "/foo/bar" and the physical file path for that root is "c:\inetpub\wwwroot\foo\bar", then PhysicalPath would be "c:\inetpub\wwwroot\foo\bar\ REQUEST_URL_IS_NOT_A_VALID_FILESYSTEM_PATH".

    Read the article

  • To ORM or Not to ORM. That is the question&hellip;

    - by Patrick Liekhus
    UPDATE:  Thanks for the feedback and comments.  I have adjusted my table below with your recommendations.  I had missed a point or two. I wanted to do a series on creating an entire project using the EDMX XAF code generation and the SpecFlow BDD Easy Test tools discussed in my earlier posts, but I thought it would be appropriate to start with a simple comparison and reasoning on why I choose to use these tools. Let’s start by defining the term ORM, or Object-Relational Mapping.  According to Wikipedia it is defined as the following: Object-relational mapping (ORM, O/RM, and O/R mapping) in computer software is a programming technique for converting data between incompatible type systems in object-oriented programming languages. This creates, in effect, a "virtual object database" that can be used from within the programming language. Why should you care?  Basically it allows you to map your business objects in code to their persistence layer behind them. And better yet, why would you want to do this?  Let me outline it in the following points: Development speed.  No more need to map repetitive tasks query results to object members.  Once the map is created the code is rendered for you. Persistence portability.  The ORM knows how to map SQL specific syntax for the persistence engine you choose.  It does not matter if it is SQL Server, Oracle and another database of your choosing. Standard/Boilerplate code is simplified.  The basic CRUD operations are consistent and case use database metadata for basic operations. So how does this help?  Well, let’s compare some of the ORM tools that I have used and/or researched.  I have been interested in ORM for some time now.  My ORM of choice for a long time was NHibernate and I still believe it has a strong case in some business situations.  However, you have to take business considerations into account and the law of diminishing returns.  Because of these two factors, my recent activity and experience has been around DevExpress eXpress Persistence Objects (XPO).  The primary reason for this is because they have the DevExpress eXpress Application Framework (XAF) that sits on top of XPO.  With this added value, the data model can be created (either database first of code first) and the Web and Windows client can be created from these maps.  While out of the box they provide some simple list and detail screens, you can verify easily extend and modify these to your liking.  DevExpress has done a tremendous job of providing enough framework while also staying out of the way when you need to extend it.  This sounds worse than it really is.  What I mean by this is that if you choose to follow DevExpress coding style and recommendations, the hooks and extension points provided allow you to do some pretty heavy lifting while also not worrying about the basics. I have put together a list of the top features that I have used to compare the limited list of ORM’s that I have exposure with.  Again, the biggest selling point in my opinion is that XPO is just a solid as any of the other ORM’s but with the added layer of XAF they become unstoppable.  And then couple that with the EDMX modeling tools and code generation, it becomes a no brainer. Designer Features Entity Framework NHibernate Fluent w/ Nhibernate Telerik OpenAccess DevExpress XPO DevExpress XPO/XAF plus Liekhus Tools Uses XML to map relationships - Yes - - -   Visual class designer interface Yes - - - - Yes Management integrated w/ Visual Studio Yes - - Yes - Yes Supports schema first approach Yes - - Yes - Yes Supports model first approach Yes - - Yes Yes Yes Supports code first approach Yes Yes Yes Yes Yes Yes Attribute driven coding style Yes - Yes - Yes Yes                 I have a very small team and limited resources with a lot of responsibilities.  In order to keep up with our customers, we must rely on tools like these.  We use the EDMX tool so that we can create a visual representation of the applications with our customers.  Second, we rely on the code generation so that we can focus on the business problems at hand and not whether a field is mapped correctly.  This keeps us from requiring as many junior level developers on our team.  I have also worked on multiple teams where they believed in writing their own “framework”.  In my experiences and opinion this is not the route to take unless you have a team dedicated to supporting just the framework.  Each time that I have worked on custom frameworks, the framework eventually becomes old, out dated and full of “performance” enhancements specific to one or two requirements.  With an ORM, there are a lot smarter people than me working on the bigger issue of persistence and performance.  Again, my recommendation would be to use an available framework and get to working on your business domain problems.  If your coding is not making money for you, why are you working on it?  Do you really need to be writing query to object member code again and again? Thanks

    Read the article

  • Pre-filtering and shaping OData feeds using WCF Data Services and the Entity Framework - Part 2

    - by rajbk
    In the previous post, you saw how to create an OData feed and pre-filter the data. In this post, we will see how to shape the data. A sample project is attached at the bottom of this post. Pre-filtering and shaping OData feeds using WCF Data Services and the Entity Framework - Part 1 Shaping the feed The Product feed we created earlier returns too much information about our products. Let’s change this so that only the following properties are returned – ProductID, ProductName, QuantityPerUnit, UnitPrice, UnitsInStock. We also want to return only Products that are not discontinued.  Splitting the Entity To shape our data according to the requirements above, we are going to split our Product Entity into two and expose one through the feed. The exposed entity will contain only the properties listed above. We will use the other Entity in our Query Interceptor to pre-filter the data so that discontinued products are not returned. Go to the design surface for the Entity Model and make a copy of the Product entity. A “Product1” Entity gets created.   Rename Product1 to ProductDetail. Right click on the Product entity and select “Add Association” Make a one to one association between Product and ProductDetails.   Keep only the properties we wish to expose on the Product entity and delete all other properties on it (see diagram below). You delete a property on an Entity by right clicking on the property and selecting “delete”. Keep the ProductID on the ProductDetail. Delete any other property on the ProductDetail entity that is already present in the Product entity. Your design surface should look like below:    Mapping Entity to Database Tables Right click on “ProductDetail” and go to “Table Mapping”   Add a mapping to the “Products” table in the Mapping Details.   After mapping ProductDetail, you should see the following.   Add a referential constraint. Lets add a referential constraint which is similar to a referential integrity constraint in SQL. Double click on the Association between the Entities and add the constraint with “Principal” set to “Product”. Let us review what we did so far. We made a copy of the Product entity and called it ProductDetail We created a one to one association between these entities Excluding the ProductID, we made sure properties were not duplicated between these entities  We added a ProductDetail entity to Products table mapping (Entity to Database). We added a referential constraint between the entities. Lets build our project. We get the following error: ”'NortwindODataFeed.Product' does not contain a definition for 'Discontinued' and no extension method 'Discontinued' accepting a first argument of type 'NortwindODataFeed.Product' could be found …" The reason for this error is because our Product Entity no longer has a “Discontinued” property. We “moved” it to the ProductDetail entity since we want our Product Entity to contain only properties that will be exposed by our feed. Since we have a one to one association between the entities, we can easily rewrite our Query Interceptor like so: [QueryInterceptor("Products")] public Expression<Func<Product, bool>> OnReadProducts() { return o => o.ProductDetail.Discontinued == false; } Similarly, all “hidden” properties of the Product table are available to us internally (through the ProductDetail Entity) for any additional logic we wish to implement. Compile the project and view the feed. We see that the feed returns only the properties that were part of the requirement.   To see the data in JSON format, you have to create a request with the following request header Accept: application/json, text/javascript, */* (easy to do in jQuery) The result should look like this: { "d" : { "results": [ { "__metadata": { "uri": "http://localhost.:2576/DataService.svc/Products(1)", "type": "NorthwindModel.Product" }, "ProductID": 1, "ProductName": "Chai", "QuantityPerUnit": "10 boxes x 20 bags", "UnitPrice": "18.0000", "UnitsInStock": 39 }, { "__metadata": { "uri": "http://localhost.:2576/DataService.svc/Products(2)", "type": "NorthwindModel.Product" }, "ProductID": 2, "ProductName": "Chang", "QuantityPerUnit": "24 - 12 oz bottles", "UnitPrice": "19.0000", "UnitsInStock": 17 }, { ... ... If anyone has the $format operation working, please post a comment. It was not working for me at the time of writing this.  We have successfully pre-filtered our data to expose only products that have not been discontinued and shaped our data so that only certain properties of the Entity are exposed. Note that there are several other ways you could implement this like creating a QueryView, Stored Procedure or DefiningQuery. You have seen how easy it is to create an OData feed, shape the data and pre-filter it by hardly writing any code of your own. For more details on OData, Google it with your favorite search engine :-) Also check out the one of the most passionate persons I have ever met, Pablo Castro – the Architect of Aristoria WCF Data Services. Watch his MIX 2010 presentation titled “OData: There's a Feed for That” here. Download Sample Project for VS 2010 RTM NortwindODataFeed.zip

    Read the article

  • Auto blocking attacking IP address

    - by dong
    This is to share my PowerShell code online. I original asked this question on MSDN forum (or TechNet?) here: http://social.technet.microsoft.com/Forums/en-US/winserversecurity/thread/f950686e-e3f8-4cf2-b8ec-2685c1ed7a77 In short, this is trying to find attacking IP address then add it into Firewall block rule. So I suppose: 1, You are running a Windows Server 2008 facing the Internet. 2, You need to have some port open for service, e.g. TCP 21 for FTP; TCP 3389 for Remote Desktop. You can see in my code I’m only dealing with these two since that’s what I opened. You can add further port number if you like, but the way to process might be different with these two. 3, I strongly suggest you use STRONG password and follow all security best practices, this ps1 code is NOT for adding security to your server, but reduce the nuisance from brute force attack, and make sys admin’s life easier: i.e. your FTP log won’t hold megabytes of nonsense, your Windows system log will not roll back and only can tell you what happened last month. 4, You are comfortable with setting up Windows Firewall rules, in my code, my rule has a name of “MY BLACKLIST”, you need to setup a similar one, and set it to BLOCK everything. 5, My rule is dangerous because it has the risk to block myself out as well. I do have a backup plan i.e. the DELL DRAC5 so that if that happens, I still can remote console to my server and reset the firewall. 6, By no means the code is perfect, the coding style, the use of PowerShell skills, the hard coded part, all can be improved, it’s just that it’s good enough for me already. It has been running on my server for more than 7 MONTHS. 7, Current code still has problem, I didn’t solve it yet, further on this point after the code. :)    #Dong Xie, March 2012  #my simple code to monitor attack and deal with it  #Windows Server 2008 Logon Type  #8: NetworkCleartext, i.e. FTP  #10: RemoteInteractive, i.e. RDP    $tick = 0;  "Start to run at: " + (get-date);    $regex1 = [regex] "192\.168\.100\.(?:101|102):3389\s+(\d+\.\d+\.\d+\.\d+)";  $regex2 = [regex] "Source Network Address:\t(\d+\.\d+\.\d+\.\d+)";    while($True) {   $blacklist = @();     "Running... (tick:" + $tick + ")"; $tick+=1;    #Port 3389  $a = @()  netstat -no | Select-String ":3389" | ? { $m = $regex1.Match($_); `    $ip = $m.Groups[1].Value; if ($m.Success -and $ip -ne "10.0.0.1") {$a = $a + $ip;} }  if ($a.count -gt 0) {    $ips = get-eventlog Security -Newest 1000 | Where-Object {$_.EventID -eq 4625 -and $_.Message -match "Logon Type:\s+10"} | foreach { `      $m = $regex2.Match($_.Message); $ip = $m.Groups[1].Value; $ip; } | Sort-Object | Tee-Object -Variable list | Get-Unique    foreach ($ip in $a) { if ($ips -contains $ip) {      if (-not ($blacklist -contains $ip)) {        $attack_count = ($list | Select-String $ip -SimpleMatch | Measure-Object).count;        "Found attacking IP on 3389: " + $ip + ", with count: " + $attack_count;        if ($attack_count -ge 20) {$blacklist = $blacklist + $ip;}      }      }    }  }      #FTP  $now = (Get-Date).AddMinutes(-5); #check only last 5 mins.     #Get-EventLog has built-in switch for EventID, Message, Time, etc. but using any of these it will be VERY slow.  $count = (Get-EventLog Security -Newest 1000 | Where-Object {$_.EventID -eq 4625 -and $_.Message -match "Logon Type:\s+8" -and `              $_.TimeGenerated.CompareTo($now) -gt 0} | Measure-Object).count;  if ($count -gt 50) #threshold  {     $ips = @();     $ips1 = dir "C:\inetpub\logs\LogFiles\FPTSVC2" | Sort-Object -Property LastWriteTime -Descending `       | select -First 1 | gc | select -Last 200 | where {$_ -match "An\+error\+occured\+during\+the\+authentication\+process."} `        | Select-String -Pattern "(\d+\.\d+\.\d+\.\d+)" | select -ExpandProperty Matches | select -ExpandProperty value | Group-Object `        | where {$_.Count -ge 10} | select -ExpandProperty Name;       $ips2 = dir "C:\inetpub\logs\LogFiles\FTPSVC3" | Sort-Object -Property LastWriteTime -Descending `       | select -First 1 | gc | select -Last 200 | where {$_ -match "An\+error\+occured\+during\+the\+authentication\+process."} `        | Select-String -Pattern "(\d+\.\d+\.\d+\.\d+)" | select -ExpandProperty Matches | select -ExpandProperty value | Group-Object `        | where {$_.Count -ge 10} | select -ExpandProperty Name;     $ips += $ips1; $ips += $ips2; $ips = $ips | where {$_ -ne "10.0.0.1"} | Sort-Object | Get-Unique;         foreach ($ip in $ips) {       if (-not ($blacklist -contains $ip)) {        "Found attacking IP on FTP: " + $ip;        $blacklist = $blacklist + $ip;       }     }  }        #Firewall change <# $current = (netsh advfirewall firewall show rule name="MY BLACKLIST" | where {$_ -match "RemoteIP"}).replace("RemoteIP:", "").replace(" ","").replace("/255.255.255.255",""); #inside $current there is no \r or \n need remove. foreach ($ip in $blacklist) { if (-not ($current -match $ip) -and -not ($ip -like "10.0.0.*")) {"Adding this IP into firewall blocklist: " + $ip; $c= 'netsh advfirewall firewall set rule name="MY BLACKLIST" new RemoteIP="{0},{1}"' -f $ip, $current; Invoke-Expression $c; } } #>    foreach ($ip in $blacklist) {    $fw=New-object –comObject HNetCfg.FwPolicy2; # http://blogs.technet.com/b/jamesone/archive/2009/02/18/how-to-manage-the-windows-firewall-settings-with-powershell.aspx    $myrule = $fw.Rules | where {$_.Name -eq "MY BLACKLIST"} | select -First 1; # Potential bug here?    if (-not ($myrule.RemoteAddresses -match $ip) -and -not ($ip -like "10.0.0.*"))      {"Adding this IP into firewall blocklist: " + $ip;         $myrule.RemoteAddresses+=(","+$ip);      }  }    Wait-Event -Timeout 30 #pause 30 secs    } # end of top while loop.   Further points: 1, I suppose the server is listening on port 3389 on server IP: 192.168.100.101 and 192.168.100.102, you need to replace that with your real IP. 2, I suppose you are Remote Desktop to this server from a workstation with IP: 10.0.0.1. Please replace as well. 3, The threshold for 3389 attack is 20, you don’t want to block yourself just because you typed your password wrong 3 times, you can change this threshold by your own reasoning. 4, FTP is checking the log for attack only to the last 5 mins, you can change that as well. 5, I suppose the server is serving FTP on both IP address and their LOG path are C:\inetpub\logs\LogFiles\FPTSVC2 and C:\inetpub\logs\LogFiles\FPTSVC3. Change accordingly. 6, FTP checking code is only asking for the last 200 lines of log, and the threshold is 10, change as you wish. 7, the code runs in a loop, you can set the loop time at the last line. To run this code, copy and paste to your editor, finish all the editing, get it to your server, and open an CMD window, then type powershell.exe –file your_powershell_file_name.ps1, it will start running, you can Ctrl-C to break it. This is what you see when it’s running: This is when it detected attack and adding the firewall rule: Regarding the design of the code: 1, There are many ways you can detect the attack, but to add an IP into a block rule is no small thing, you need to think hard before doing it, reason for that may include: You don’t want block yourself; and not blocking your customer/user, i.e. the good guy. 2, Thus for each service/port, I double check. For 3389, first it needs to show in netstat.exe, then the Event log; for FTP, first check the Event log, then the FTP log files. 3, At three places I need to make sure I’m not adding myself into the block rule. –ne with single IP, –like with subnet.   Now the final bit: 1, The code will stop working after a while (depends on how busy you are attacked, could be weeks, months, or days?!) It will throw Red error message in CMD, don’t Panic, it does no harm, but it also no longer blocking new attack. THE REASON is not confirmed with MS people: the COM object to manage firewall, you can only give it a list of IP addresses to the length of around 32KB I think, once it reaches the limit, you get the error message. 2, This is in fact my second solution to use the COM object, the first solution is still in the comment block for your reference, which is using netsh, that fails because being run from CMD, you can only throw it a list of IP to 8KB. 3, I haven’t worked the workaround yet, some ideas include: wrap that RemoteAddresses setting line with error checking and once it reaches the limit, use the newly detected IP to be the list, not appending to it. This basically reset your block rule to ground zero and lose the previous bad IPs. This does no harm as it sounds, because given a certain period has passed, any these bad IPs still not repent and continue the attack to you, it only got 30 seconds or 20 guesses of your password before you block it again. And there is the benefit that the bad IP may turn back to the good hands again, and you are not blocking a potential customer or your CEO’s home pc because once upon a time, it’s a zombie. Thus the ZEN of blocking: never block any IP for too long. 4, But if you insist to block the ugly forever, my other ideas include: You call MS support, ask them how can we set an arbitrary length of IP addresses in a rule; at least from my experiences at the Forum, they don’t know and they don’t care, because they think the dynamic blocking should be done by some expensive hardware. Or, from programming perspective, you can create a new rule once the old is full, then you’ll have MY BLACKLIST1, MY  BLACKLIST2, MY BLACKLIST3, … etc. Once in a while you can compile them together and start a business to sell your blacklist on the market! Enjoy the code! p.s. (PowerShell is REALLY REALLY GREAT!)

    Read the article

  • Copying Columns from Grid to Clipboard in SQL Developer

    - by thatjeffsmith
    There are several ways to get data from a query or a table|view to the clipboard. You know the tried and true, copy and paste. But what if you only want one or more columns, not every column? There are several ways to do this, let’s see if we can’t identify all of them. Write your query to only include the data you want Obvious? Yes. Needed to be said? Definitely. The best tuning tip is to only ask for the data you need, only when you absolutely need it. But let’s look at a few more practical ways to do this. Hide the unwanted columns Mouse right click on an column header. In the context menu, select ‘Columns.’ Hide the columns you don’t want. Copy and paste. WYSIWYG Grids, Hide Columns and Filter Rows Mouse select the columns Obvious, but a bit painful. For a very large dataset, you’ll be holding down the Shift and PageDown buttons – but it works. Remember to use Ctrl+Shift+C to get the column headers with the data. Use the Export Wizard This used to be called ‘Unload’ – agreed, not a great name. So, we changed it. In a grid, right mouse click on the data, and on the context menu, select ‘Export…’ Select your format – I suggest ‘delimited’ or ‘fixed’ for copying data to the clipboard. You can export to the clipboard, yes you can! Click ‘Next.’ Click in the Columns dialog, and choose the columns you want copied. Trim the columns you don't want copied Click ‘Finish.’ Alt or Ctrl tab to your window or application of choice. And Paste! "FIRST_NAME" "LAST_NAME" "Donald" "OConnell" "Douglas" "Grant" "Jennifer" "Whalen" "Pat" "Fay" "Susan" "Mavris" "William" "Gietz" "Alexander" "Hunold" "Bruce" "Ernst" "David" "Austin" "Valli" "Pataballa" "Diana" "Lorentz" "Daniel" "Faviet" "John" "Chen" "Ismael" "Sciarra" "Jose Manuel" "Urman" "Luis" "Popp" "Alexander" "Khoo" "Shelli" "Baida" "Sigal" "Tobias" "Guy" "Himuro" "Karen" "Colmenares" "Matthew" "Weiss" "Adam" "Fripp" "Payam" "Kaufling" "Shanta" "Vollman" "Kevin" "Mourgos" "Julia" "Nayer" "Irene" "Mikkilineni" ... There’s probably at least 2 or 3 more ways, but… But, try these and let me know how we can improve things. I’ve already gotten a request to be able to include the SQL text used to populate the dataset on the the copy to clipboard, and it’s now on our to-do list

    Read the article

  • Searching for the last logon of users in Active Directory

    - by Robert May
    I needed to clean out a bunch of old accounts at Veracity Solutions, and wanted to delete those that hadn’t used their account in more than a year. I found that AD has a property on objects called the lastLogonTimestamp.  However, this value isn’t exposed to you in any useful fashion.  Sure, you can pull up ADSI Edit and and eventually get to it there, but it’s painful. I spent some time searching, and discovered that there’s not much out there to help, so I thought a blog post showing exactly how to get at this information would be in order. Basically, what you end up doing is using System.DirectoryServices to search for accounts and then filtering those for users, doing some conversion and such to make it happen.  Basically, the end result of this is that you get a list of users with their logon information and you can then do with that what you will.  I turned my list into an observable collection and bound it into a XAML form. One important note, you need to add a reference to ActiveDs Type Library in the COM section of the world in references to get to LargeInteger. Here’s the class: namespace Veracity.Utilities { using System; using System.Collections.Generic; using System.DirectoryServices; using ActiveDs; using log4net; /// <summary> /// Finds users inside of the active directory system. /// </summary> public class UserFinder { /// <summary> /// Creates the default logger /// </summary> private static readonly ILog log = LogManager.GetLogger(typeof(UserFinder)); /// <summary> /// Finds last logon information /// </summary> /// <param name="domain">The domain to search.</param> /// <param name="userName">The username for the query.</param> /// <param name="password">The password for the query.</param> /// <returns>A list of users with their last logon information.</returns> public IList<UserLoginInformation> GetLastLogonInformation(string domain, string userName, string password) { IList<UserLoginInformation> result = new List<UserLoginInformation>(); DirectoryEntry entry = new DirectoryEntry(domain, userName, password, AuthenticationTypes.Secure); DirectorySearcher directorySearcher = new DirectorySearcher(entry); directorySearcher.PropertyNamesOnly = true; directorySearcher.PropertiesToLoad.Add("name"); directorySearcher.PropertiesToLoad.Add("lastLogonTimeStamp"); SearchResultCollection searchResults; try { searchResults = directorySearcher.FindAll(); } catch (System.Exception ex) { log.Error("Failed to do a find all.", ex); throw; } try { foreach (SearchResult searchResult in searchResults) { DirectoryEntry resultEntry = searchResult.GetDirectoryEntry(); if (resultEntry.SchemaClassName == "user") { UserLoginInformation logon = new UserLoginInformation(); logon.Name = resultEntry.Name; PropertyValueCollection timeStampObject = resultEntry.Properties["lastLogonTimeStamp"]; if (timeStampObject.Count > 0) { IADsLargeInteger logonTimeStamp = (IADsLargeInteger)timeStampObject[0]; long lastLogon = (long)((uint)logonTimeStamp.LowPart + (((long)logonTimeStamp.HighPart) << 32)); logon.LastLogonTime = DateTime.FromFileTime(lastLogon); } result.Add(logon); } } } catch (System.Exception ex) { log.Error("Failed to iterate search results.", ex); throw; } return result; } } } Some important things to note: Username and Password can be set to null and if your computer us part of the domain, this may still work. Domain should be set to something like LDAP://servername/CN=Users,CN=Domain,CN=com You’re actually getting a com object back, so that’s why the LongInteger conversions are happening.  The class for UserLoginInformation looks like this:   namespace Veracity.Utilities { using System; /// <summary> /// Represents user login information. /// </summary> public class UserLoginInformation { /// <summary> /// Gets or sets Name /// </summary> public string Name { get; set; } /// <summary> /// Gets or sets LastLogonTime /// </summary> public DateTime LastLogonTime { get; set; } /// <summary> /// Gets the age of the account. /// </summary> public TimeSpan AccountAge { get { TimeSpan result = TimeSpan.Zero; if (this.LastLogonTime != DateTime.MinValue) { result = DateTime.Now.Subtract(this.LastLogonTime); } return result; } } } } I hope this is useful and instructive. Technorati Tags: Active Directory

    Read the article

  • help with fixing fwts errors log

    - by jasmines
    Here is an extract of results.log: MTRR validation. Test 1 of 3: Validate the kernel MTRR IOMEM setup. FAILED [MEDIUM] MTRRIncorrectAttr: Test 1, Memory range 0xc0000000 to 0xdfffffff (PCI Bus 0000:00) has incorrect attribute Write-Combining. FAILED [MEDIUM] MTRRIncorrectAttr: Test 1, Memory range 0xfee01000 to 0xffffffff (PCI Bus 0000:00) has incorrect attribute Write-Protect. ==================================================================================================== Test 1 of 1: Kernel log error check. Kernel message: [ 0.208079] [Firmware Bug]: ACPI: BIOS _OSI(Linux) query ignored ADVICE: This is not exactly a failure mode but a warning from the kernel. The _OSI() method has implemented a match to the 'Linux' query in the DSDT and this is redundant because the ACPI driver matches onto the Windows _OSI strings by default. FAILED [HIGH] KlogACPIErrorMethodExecutionParse: Test 1, HIGH Kernel message: [ 3.512783] ACPI Error : Method parse/execution failed [\_SB_.PCI0.GFX0._DOD] (Node f7425858), AE_AML_PACKAGE_LIMIT (20110623/psparse-536) ADVICE: This is a bug picked up by the kernel, but as yet, the firmware test suite has no diagnostic advice for this particular problem. Found 1 unique errors in kernel log. ==================================================================================================== Check if system is using latest microcode. ---------------------------------------------------------------------------------------------------- Cannot read microcode file /usr/share/misc/intel-microcode.dat. Aborted test, initialisation failed. ==================================================================================================== MSR register tests. FAILED [MEDIUM] MSRCPUsInconsistent: Test 1, MSR SYSENTER_ESP (0x175) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0xffffffffffffffff). MSR CPU 0 -> 0xf7bb9c40 vs CPU 1 -> 0xf7bc7c40 FAILED [MEDIUM] MSRCPUsInconsistent: Test 1, MSR MISC_ENABLE (0x1a0) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0x400c51889). MSR CPU 0 -> 0x850088 vs CPU 1 -> 0x850089 ==================================================================================================== Checks firmware has set PCI Express MaxReadReq to a higher value on non-motherboard devices. ---------------------------------------------------------------------------------------------------- Test 1 of 1: Check firmware settings MaxReadReq for PCI Express devices. MaxReadReq for pci://00:00:1b.0 Audio device: Intel Corporation 82801I (ICH9 Family) HD Audio Controller (rev 03) is low (128) [Audio device]. MaxReadReq for pci://00:02:00.0 Network controller: Intel Corporation PRO/Wireless 5100 AGN [Shiloh] Network Connection is low (128) [Network controller]. FAILED [LOW] LowMaxReadReq: Test 1, 2 devices have low MaxReadReq settings. Firmware may have configured these too low. ADVICE: The MaxReadRequest size is set too low and will affect performance. It will provide excellent bus sharing at the cost of bus data transfer rates. Although not a critical issue, it may be worth considering setting the MaxReadRequest size to 256 or 512 to increase throughput on the PCI Express bus. Some drivers (for example the Brocade Fibre Channel driver) allow one to override the firmware settings. Where possible, this BIOS configuration setting is worth increasing it a little more for better performance at a small reduction of bus sharing. ==================================================================================================== PCIe ASPM check. ---------------------------------------------------------------------------------------------------- Test 1 of 2: PCIe ASPM ACPI test. PCIE ASPM is not controlled by Linux kernel. ADVICE: BIOS reports that Linux kernel should not modify ASPM settings that BIOS configured. It can be intentional because hardware vendors identified some capability bugs between the motherboard and the add-on cards. Test 2 of 2: PCIe ASPM registers test. WARNING: Test 2, RP 00h:1Ch.01h L0s not enabled. WARNING: Test 2, RP 00h:1Ch.01h L1 not enabled. WARNING: Test 2, Device 02h:00h.00h L0s not enabled. WARNING: Test 2, Device 02h:00h.00h L1 not enabled. PASSED: Test 2, PCIE aspm setting matched was matched. WARNING: Test 2, RP 00h:1Ch.05h L0s not enabled. WARNING: Test 2, RP 00h:1Ch.05h L1 not enabled. WARNING: Test 2, Device 85h:00h.00h L0s not enabled. WARNING: Test 2, Device 85h:00h.00h L1 not enabled. PASSED: Test 2, PCIE aspm setting matched was matched. ==================================================================================================== Extract and analyse Windows Management Instrumentation (WMI). Test 1 of 2: Check Windows Management Instrumentation in DSDT Found WMI Method WMAA with GUID: 5FB7F034-2C63-45E9-BE91-3D44E2C707E4, Instance 0x01 Found WMI Event, Notifier ID: 0x80, GUID: 95F24279-4D7B-4334-9387-ACCDC67EF61C, Instance 0x01 PASSED: Test 1, GUID 95F24279-4D7B-4334-9387-ACCDC67EF61C is handled by driver hp-wmi (Vendor: HP). Found WMI Event, Notifier ID: 0xa0, GUID: 2B814318-4BE8-4707-9D84-A190A859B5D0, Instance 0x01 FAILED [MEDIUM] WMIUnknownGUID: Test 1, GUID 2B814318-4BE8-4707-9D84-A190A859B5D0 is unknown to the kernel, a driver may need to be implemented for this GUID. ADVICE: A WMI driver probably needs to be written for this event. It can checked for using: wmi_has_guid("2B814318-4BE8-4707-9D84-A190A859B5D0"). One can install a notify handler using wmi_install_notify_handler("2B814318-4BE8-4707-9D84-A190A859B5D0", handler, NULL). http://lwn.net/Articles/391230 describes how to write an appropriate driver. Found WMI Object, Object ID AB, GUID: 05901221-D566-11D1-B2F0-00A0C9062910, Instance 0x01, Flags: 00 Found WMI Method WMBA with GUID: 1F4C91EB-DC5C-460B-951D-C7CB9B4B8D5E, Instance 0x01 Found WMI Object, Object ID BC, GUID: 2D114B49-2DFB-4130-B8FE-4A3C09E75133, Instance 0x7f, Flags: 00 Found WMI Object, Object ID BD, GUID: 988D08E3-68F4-4C35-AF3E-6A1B8106F83C, Instance 0x19, Flags: 00 Found WMI Object, Object ID BE, GUID: 14EA9746-CE1F-4098-A0E0-7045CB4DA745, Instance 0x01, Flags: 00 Found WMI Object, Object ID BF, GUID: 322F2028-0F84-4901-988E-015176049E2D, Instance 0x01, Flags: 00 Found WMI Object, Object ID BG, GUID: 8232DE3D-663D-4327-A8F4-E293ADB9BF05, Instance 0x01, Flags: 00 Found WMI Object, Object ID BH, GUID: 8F1F6436-9F42-42C8-BADC-0E9424F20C9A, Instance 0x00, Flags: 00 Found WMI Object, Object ID BI, GUID: 8F1F6435-9F42-42C8-BADC-0E9424F20C9A, Instance 0x00, Flags: 00 Found WMI Method WMAC with GUID: 7391A661-223A-47DB-A77A-7BE84C60822D, Instance 0x01 Found WMI Object, Object ID BJ, GUID: DF4E63B6-3BBC-4858-9737-C74F82F821F3, Instance 0x05, Flags: 00 ==================================================================================================== Disassemble DSDT to check for _OSI("Linux"). ---------------------------------------------------------------------------------------------------- Test 1 of 1: Disassemble DSDT to check for _OSI("Linux"). This is not strictly a failure mode, it just alerts one that this has been defined in the DSDT and probably should be avoided since the Linux ACPI driver matches onto the Windows _OSI strings { If (_OSI ("Linux")) { Store (0x03E8, OSYS) } If (_OSI ("Windows 2001")) { Store (0x07D1, OSYS) } If (_OSI ("Windows 2001 SP1")) { Store (0x07D1, OSYS) } If (_OSI ("Windows 2001 SP2")) { Store (0x07D2, OSYS) } If (_OSI ("Windows 2006")) { Store (0x07D6, OSYS) } If (LAnd (MPEN, LEqual (OSYS, 0x07D1))) { TRAP (0x01, 0x48) } TRAP (0x03, 0x35) } WARNING: Test 1, DSDT implements a deprecated _OSI("Linux") test. ==================================================================================================== 0 passed, 0 failed, 1 warnings, 0 aborted, 0 skipped, 0 info only. ==================================================================================================== ACPI DSDT Method Semantic Tests. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP Failed to install global event handler. Test 22 of 93: Check _PSR (Power Source). ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 22, Detected an infinite loop when evaluating method '\_SB_.AC__._PSR'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 22, \_SB_.AC__._PSR correctly acquired and released locks 16 times. Test 35 of 93: Check _TMP (Thermal Zone Current Temp). ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 35, Detected an infinite loop when evaluating method '\_TZ_.DTSZ._TMP'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 35, \_TZ_.DTSZ._TMP correctly acquired and released locks 14 times. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 35, Detected an infinite loop when evaluating method '\_TZ_.CPUZ._TMP'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 35, \_TZ_.CPUZ._TMP correctly acquired and released locks 10 times. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 35, Detected an infinite loop when evaluating method '\_TZ_.SKNZ._TMP'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 35, \_TZ_.SKNZ._TMP correctly acquired and released locks 10 times. PASSED: Test 35, _TMP correctly returned sane looking value 0x00000b4c (289.2 degrees K) PASSED: Test 35, \_TZ_.BATZ._TMP correctly acquired and released locks 9 times. PASSED: Test 35, _TMP correctly returned sane looking value 0x00000aac (273.2 degrees K) PASSED: Test 35, \_TZ_.FDTZ._TMP correctly acquired and released locks 7 times. Test 46 of 93: Check _DIS (Disable). FAILED [MEDIUM] MethodShouldReturnNothing: Test 46, \_SB_.PCI0.LPCB.SIO_.COM1._DIS returned values, but was expected to return nothing. Object returned: INTEGER: 0x00000000 ADVICE: This probably won't cause any errors, but it should be fixed as the AML code is not conforming to the expected behaviour as described in the ACPI specification. FAILED [MEDIUM] MethodShouldReturnNothing: Test 46, \_SB_.PCI0.LPCB.SIO_.LPT0._DIS returned values, but was expected to return nothing. Object returned: INTEGER: 0x00000000 ADVICE: This probably won't cause any errors, but it should be fixed as the AML code is not conforming to the expected behaviour as described in the ACPI specification. Test 61 of 93: Check _WAK (System Wake). Test _WAK(1) System Wake, State S1. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(2) System Wake, State S2. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(3) System Wake, State S3. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(4) System Wake, State S4. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(5) System Wake, State S5. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test 87 of 93: Check _BCL (Query List of Brightness Control Levels Supported). Package has 2 elements: 00: INTEGER: 0x00000000 01: INTEGER: 0x00000000 FAILED [MEDIUM] Method_BCLElementCount: Test 87, Method _BCL should return a package of more than 2 integers, got just 2. Test 88 of 93: Check _BCM (Set Brightness Level). ACPICA Exception AE_AML_PACKAGE_LIMIT during execution of method _BCM FAILED [CRITICAL] AEAMLPackgeLimit: Test 88, Detected error 'Package limit' when evaluating '\_SB_.PCI0.GFX0.DD02._BCM'. ==================================================================================================== ACPI table settings sanity checks. ---------------------------------------------------------------------------------------------------- Test 1 of 1: Check ACPI tables. PASSED: Test 1, Table APIC passed. Table ECDT not present to check. FAILED [MEDIUM] FADT32And64BothDefined: Test 1, FADT 32 bit FIRMWARE_CONTROL is non-zero, and X_FIRMWARE_CONTROL is also non-zero. Section 5.2.9 of the ACPI specification states that if the FIRMWARE_CONTROL is non-zero then X_FIRMWARE_CONTROL must be set to zero. ADVICE: The FADT FIRMWARE_CTRL is a 32 bit pointer that points to the physical memory address of the Firmware ACPI Control Structure (FACS). There is also an extended 64 bit version of this, the X_FIRMWARE_CTRL pointer that also can point to the FACS. Section 5.2.9 of the ACPI specification states that if the X_FIRMWARE_CTRL field contains a non zero value then the FIRMWARE_CTRL field *must* be zero. This error is also detected by the Linux kernel. If FIRMWARE_CTRL and X_FIRMWARE_CTRL are defined, then the kernel just uses the 64 bit version of the pointer. PASSED: Test 1, Table HPET passed. PASSED: Test 1, Table MCFG passed. PASSED: Test 1, Table RSDT passed. PASSED: Test 1, Table RSDP passed. Table SBST not present to check. PASSED: Test 1, Table XSDT passed. ==================================================================================================== Re-assemble DSDT and find syntax errors and warnings. ---------------------------------------------------------------------------------------------------- Test 1 of 2: Disassemble and reassemble DSDT FAILED [HIGH] AMLAssemblerError4043: Test 1, Assembler error in line 2261 Line | AML source ---------------------------------------------------------------------------------------------------- 02258| 0x00000000, // Range Minimum 02259| 0xFEDFFFFF, // Range Maximum 02260| 0x00000000, // Translation Offset 02261| 0x00000000, // Length | ^ | error 4043: Invalid combination of Length and Min/Max fixed flags 02262| ,, _Y0E, AddressRangeMemory, TypeStatic) 02263| DWordMemory (ResourceProducer, PosDecode, MinFixed, MaxFixed, Cacheable, ReadWrite, 02264| 0x00000000, // Granularity ==================================================================================================== ADVICE: (for error #4043): This occurs if the length is zero and just one of the resource MIF/MAF flags are set, or the length is non-zero and resource MIF/MAF flags are both set. These are illegal combinations and need to be fixed. See section 6.4.3.5 Address Space Resource Descriptors of version 4.0a of the ACPI specification for more details. FAILED [HIGH] AMLAssemblerError4050: Test 1, Assembler error in line 2268 Line | AML source ---------------------------------------------------------------------------------------------------- 02265| 0xFEE01000, // Range Minimum 02266| 0xFFFFFFFF, // Range Maximum 02267| 0x00000000, // Translation Offset 02268| 0x011FEFFF, // Length | ^ | error 4050: Length is not equal to fixed Min/Max window 02269| ,, , AddressRangeMemory, TypeStatic) 02270| }) 02271| Method (_CRS, 0, Serialized) ==================================================================================================== ADVICE: (for error #4050): The minimum address is greater than the maximum address. This is illegal. FAILED [HIGH] AMLAssemblerError1104: Test 1, Assembler error in line 8885 Line | AML source ---------------------------------------------------------------------------------------------------- 08882| Method (_DIS, 0, NotSerialized) 08883| { 08884| DSOD (0x02) 08885| Return (0x00) | ^ | warning level 0 1104: Reserved method should not return a value (_DIS) 08886| } 08887| 08888| Method (_SRS, 1, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 1, Assembler error in line 9195 Line | AML source ---------------------------------------------------------------------------------------------------- 09192| Method (_DIS, 0, NotSerialized) 09193| { 09194| DSOD (0x01) 09195| Return (0x00) | ^ | warning level 0 1104: Reserved method should not return a value (_DIS) 09196| } 09197| 09198| Method (_SRS, 1, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1127: Test 1, Assembler error in line 9242 Line | AML source ---------------------------------------------------------------------------------------------------- 09239| CreateWordField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y21._MAX, MAX2) 09240| CreateByteField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y21._LEN, LEN2) 09241| CreateWordField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y22._INT, IRQ0) 09242| CreateWordField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y23._DMA, DMA0) | ^ | warning level 0 1127: ResourceTag smaller than Field (Tag: 8 bits, Field: 16 bits) 09243| If (RLPD) 09244| { 09245| Store (0x00, Local0) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1128: Test 1, Assembler error in line 18682 Line | AML source ---------------------------------------------------------------------------------------------------- 18679| Store (0x01, Index (DerefOf (Index (Local0, 0x02)), 0x01)) 18680| If (And (WDPE, 0x40)) 18681| { 18682| Wait (\_SB.BEVT, 0x10) | ^ | warning level 0 1128: Result is not used, possible operator timeout will be missed 18683| } 18684| 18685| Store (BRID, Index (DerefOf (Index (Local0, 0x02)), 0x02)) ==================================================================================================== ADVICE: (for warning level 0 #1128): The operation can possibly timeout, and hence the return value indicates an timeout error. However, because the return value is not checked this very probably indicates that the code is buggy. A possible scenario is that a mutex times out and the code attempts to access data in a critical region when it should not. This will lead to undefined behaviour. This should be fixed. Table DSDT (0) reassembly: Found 2 errors, 4 warnings. Test 2 of 2: Disassemble and reassemble SSDT PASSED: Test 2, SSDT (0) reassembly, Found 0 errors, 0 warnings. FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 60 Line | AML source ---------------------------------------------------------------------------------------------------- 00057| { 00058| Store (CPDC (Arg0), Local0) 00059| GCAP (Local0) 00060| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00061| } 00062| 00063| Method (_OSC, 4, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 174 Line | AML source ---------------------------------------------------------------------------------------------------- 00171| { 00172| Store (\_PR.CPU0.CPDC (Arg0), Local0) 00173| GCAP (Local0) 00174| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00175| } 00176| 00177| Method (_OSC, 4, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 244 Line | AML source ---------------------------------------------------------------------------------------------------- 00241| { 00242| Store (\_PR.CPU0.CPDC (Arg0), Local0) 00243| GCAP (Local0) 00244| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00245| } 00246| 00247| Method (_OSC, 4, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 290 Line | AML source ---------------------------------------------------------------------------------------------------- 00287| { 00288| Store (\_PR.CPU0.CPDC (Arg0), Local0) 00289| GCAP (Local0) 00290| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00291| } 00292| 00293| Method (_OSC, 4, NotSerialized) ==================================================================================================== Table SSDT (1) reassembly: Found 0 errors, 4 warnings. PASSED: Test 2, SSDT (2) reassembly, Found 0 errors, 0 warnings. PASSED: Test 2, SSDT (3) reassembly, Found 0 errors, 0 warnings. ==================================================================================================== 3 passed, 10 failed, 0 warnings, 0 aborted, 0 skipped, 0 info only. ==================================================================================================== Critical failures: 1 method test, at 1 log line: 1449: Detected error 'Package limit' when evaluating '\_SB_.PCI0.GFX0.DD02._BCM'. High failures: 11 klog test, at 1 log line: 121: HIGH Kernel message: [ 3.512783] ACPI Error: Method parse/execution failed [\_SB_.PCI0.GFX0._DOD] (Node f7425858), AE_AML_PACKAGE_LIMIT (20110623/psparse-536) syntaxcheck test, at 1 log line: 1668: Assembler error in line 2261 syntaxcheck test, at 1 log line: 1687: Assembler error in line 2268 syntaxcheck test, at 1 log line: 1703: Assembler error in line 8885 syntaxcheck test, at 1 log line: 1716: Assembler error in line 9195 syntaxcheck test, at 1 log line: 1729: Assembler error in line 9242 syntaxcheck test, at 1 log line: 1742: Assembler error in line 18682 syntaxcheck test, at 1 log line: 1766: Assembler error in line 60 syntaxcheck test, at 1 log line: 1779: Assembler error in line 174 syntaxcheck test, at 1 log line: 1792: Assembler error in line 244 syntaxcheck test, at 1 log line: 1805: Assembler error in line 290 Medium failures: 9 mtrr test, at 1 log line: 76: Memory range 0xc0000000 to 0xdfffffff (PCI Bus 0000:00) has incorrect attribute Write-Combining. mtrr test, at 1 log line: 78: Memory range 0xfee01000 to 0xffffffff (PCI Bus 0000:00) has incorrect attribute Write-Protect. msr test, at 1 log line: 165: MSR SYSENTER_ESP (0x175) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0xffffffffffffffff). msr test, at 1 log line: 173: MSR MISC_ENABLE (0x1a0) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0x400c51889). wmi test, at 1 log line: 528: GUID 2B814318-4BE8-4707-9D84-A190A859B5D0 is unknown to the kernel, a driver may need to be implemented for this GUID. method test, at 1 log line: 1002: \_SB_.PCI0.LPCB.SIO_.COM1._DIS returned values, but was expected to return nothing. method test, at 1 log line: 1011: \_SB_.PCI0.LPCB.SIO_.LPT0._DIS returned values, but was expected to return nothing. method test, at 1 log line: 1443: Method _BCL should return a package of more than 2 integers, got just 2. acpitables test, at 1 log line: 1643: FADT 32 bit FIRMWARE_CONTROL is non-zero, and X_FIRMWARE_CONTROL is also non-zero. Se

    Read the article

  • Where do we put "asking the world" code when we separate computation from side effects?

    - by Alexey
    According to Command-Query Separation principle, as well as Thinking in Data and DDD with Clojure presentations one should separate side effects (modifying the world) from computations and decisions, so that it would be easier to understand and test both parts. This leaves an unanswered question: where relatively to the boundary should we put "asking the world"? On the one hand, requesting data from external systems (like database, extental services' APIs etc) is not referentially transparent and thus should not sit together with pure computational and decision making code. On the other hand, it's problematic, or maybe impossible to tease them apart from computational part and pass it as an argument as because we may not know in advance which data we may need to request.

    Read the article

  • Configuring thouands of related products in Magento?

    - by Anonymous -
    I'm at a stage with a Magento store I'm developing where I've added all the products (all 6000 of them) and now would like to configure related products to up my conversion rate a bit. I was wondering if there was an extension anybody knew of that functions similarly to this one, with the most current version of Magento (Community Edition, 1.6.1). If not, would anyone be able to provide some pointers for writing a script that will run through each product and add 1-5 related products. I have a fairly basic idea of taking product title text and just doing a simple text similarity query between other product titles for now, just to get some related products up there, but the Magento database isn't making a terribly large amount of sense. Thanks to anyone who can shed some light on this. :)

    Read the article

  • NoSQL Memcached API for MySQL: Latest Updates

    - by Mat Keep
    With data volumes exploding, it is vital to be able to ingest and query data at high speed. For this reason, MySQL has implemented NoSQL interfaces directly to the InnoDB and MySQL Cluster (NDB) storage engines, which bypass the SQL layer completely. Without SQL parsing and optimization, Key-Value data can be written directly to MySQL tables up to 9x faster, while maintaining ACID guarantees. In addition, users can continue to run complex queries with SQL across the same data set, providing real-time analytics to the business or anonymizing sensitive data before loading to big data platforms such as Hadoop, while still maintaining all of the advantages of their existing relational database infrastructure. This and more is discussed in the latest Guide to MySQL and NoSQL where you can learn more about using the APIs to scale new generations of web, cloud, mobile and social applications on the world's most widely deployed open source database The native Memcached API is part of the MySQL 5.6 Release Candidate, and is already available in the GA release of MySQL Cluster. By using the ubiquitous Memcached API for writing and reading data, developers can preserve their investments in Memcached infrastructure by re-using existing Memcached clients, while also eliminating the need for application changes. Speed, when combined with flexibility, is essential in the world of growing data volumes and variability. Complementing NoSQL access, support for on-line DDL (Data Definition Language) operations in MySQL 5.6 and MySQL Cluster enables DevOps teams to dynamically update their database schema to accommodate rapidly changing requirements, such as the need to capture additional data generated by their applications. These changes can be made without database downtime. Using the Memcached interface, developers do not need to define a schema at all when using MySQL Cluster. Lets look a little more closely at the Memcached implementations for both InnoDB and MySQL Cluster. Memcached Implementation for InnoDB The Memcached API for InnoDB is previewed as part of the MySQL 5.6 Release Candidate. As illustrated in the following figure, Memcached for InnoDB is implemented via a Memcached daemon plug-in to the mysqld process, with the Memcached protocol mapped to the native InnoDB API. Figure 1: Memcached API Implementation for InnoDB With the Memcached daemon running in the same process space, users get very low latency access to their data while also leveraging the scalability enhancements delivered with InnoDB and a simple deployment and management model. Multiple web / application servers can remotely access the Memcached / InnoDB server to get direct access to a shared data set. With simultaneous SQL access, users can maintain all the advanced functionality offered by InnoDB including support for Foreign Keys, XA transactions and complex JOIN operations. Benchmarks demonstrate that the NoSQL Memcached API for InnoDB delivers up to 9x higher performance than the SQL interface when inserting new key/value pairs, with a single low-end commodity server supporting nearly 70,000 Transactions per Second. Figure 2: Over 9x Faster INSERT Operations The delivered performance demonstrates MySQL with the native Memcached NoSQL interface is well suited for high-speed inserts with the added assurance of transactional guarantees. You can check out the latest Memcached / InnoDB developments and benchmarks here You can learn how to configure the Memcached API for InnoDB here Memcached Implementation for MySQL Cluster Memcached API support for MySQL Cluster was introduced with General Availability (GA) of the 7.2 release, and joins an extensive range of NoSQL interfaces that are already available for MySQL Cluster Like Memcached, MySQL Cluster provides a distributed hash table with in-memory performance. MySQL Cluster extends Memcached functionality by adding support for write-intensive workloads, a full relational model with ACID compliance (including persistence), rich query support, auto-sharding and 99.999% availability, with extensive management and monitoring capabilities. All writes are committed directly to MySQL Cluster, eliminating cache invalidation and the overhead of data consistency checking to ensure complete synchronization between the database and cache. Figure 3: Memcached API Implementation with MySQL Cluster Implementation is simple: 1. The application sends reads and writes to the Memcached process (using the standard Memcached API). 2. This invokes the Memcached Driver for NDB (which is part of the same process) 3. The NDB API is called, providing for very quick access to the data held in MySQL Cluster’s data nodes. The solution has been designed to be very flexible, allowing the application architect to find a configuration that best fits their needs. It is possible to co-locate the Memcached API in either the data nodes or application nodes, or alternatively within a dedicated Memcached layer. The benefit of this flexible approach to deployment is that users can configure behavior on a per-key-prefix basis (through tables in MySQL Cluster) and the application doesn’t have to care – it just uses the Memcached API and relies on the software to store data in the right place(s) and to keep everything synchronized. Using Memcached for Schema-less Data By default, every Key / Value is written to the same table with each Key / Value pair stored in a single row – thus allowing schema-less data storage. Alternatively, the developer can define a key-prefix so that each value is linked to a pre-defined column in a specific table. Of course if the application needs to access the same data through SQL then developers can map key prefixes to existing table columns, enabling Memcached access to schema-structured data already stored in MySQL Cluster. Conclusion Download the Guide to MySQL and NoSQL to learn more about NoSQL APIs and how you can use them to scale new generations of web, cloud, mobile and social applications on the world's most widely deployed open source database See how to build a social app with MySQL Cluster and the Memcached API from our on-demand webinar or take a look at the docs Don't hesitate to use the comments section below for any questions you may have 

    Read the article

  • Sharp HealthCare Reduces Storage Requirements by 50% with Oracle Advanced Compression

    - by [email protected]
    Sharp HealthCare is an award-winning integrated regional health care delivery system based in San Diego, California, with 2,600 physicians and more than 14,000 employees. Sharp HealthCare's data warehouse forms a vital part of the information system's infrastructure and is used to separate business intelligence reporting from time-critical health care transactional systems. Faced with tremendous data growth, Sharp HealthCare decided to replace their existing Microsoft products with a solution based on Oracle Database 11g and to implement Oracle Advanced Compression. Join us to hear directly from the primary DBA for the Data Warehouse Application Team, Kim Nguyen, how the new environment significantly reduced Sharp HealthCare's storage requirements and improved query performance.

    Read the article

  • SQL SERVER When are Statistics Updated What triggers Statistics to Update

    If you are an SQL Server Consultant/Trainer involved with Performance Tuning and Query Optimization, I am sure you have faced the following questions many times.When is statistics updated? What is the interval of Statistics update? What is the algorithm behind update statistics? These are the puzzling questions and more.I searched the Internet as well many [...]...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • C#/.NET Little Wonders: Of LINQ and Lambdas - A Presentation

    - by James Michael Hare
    Once again, in this series of posts I look at the parts of the .NET Framework that may seem trivial, but can help improve your code by making it easier to write and maintain. The index of all my past little wonders posts can be found here. Today I’m giving a brief beginner’s guide to LINQ and Lambdas at the St. Louis .NET User’s Group so I thought I’d post the presentation here as well.  I updated the presentation a bit as well as added some notes on the query syntax.  Enjoy! The C#/.NET Fundaments: Of Lambdas and LINQ Presentation Of Lambdas and LINQ View more presentations from BlackRabbitCoder   Technorati Tags: C#, CSharp, .NET, Little Wonders, LINQ, Lambdas

    Read the article

  • How to tweet automatically when you push a new package to nuget.org

    - by Daniel Cazzulino
    Wouldn’t it be nice if your followers could be notified whenever you publish a new version of a NuGet package? Currently, nuget.org offers no support for this, but with the following tricks, you can get it working without programming. The essential idea is to use the OData feed that nuget.org exposes to build an RSS feed with new items as you publish them, and have IFTTT do the tweeting from it. The tools we’ll use to get this working are: LinqPad: to examine the nuget.org OData feed at https://nuget.org/api/v2  Yahoo Pipes: to tweak the OData feed output so that it looks like a “plain” feed IFTTT: to consume the pipe output and auto-tweet on new items   Exploring NuGet OData Feed with LinqPad In order to build the query that will become your tweets’ source, we will add a new connection in LinqPad by clicking on the “Add Connection” link:...Read full article

    Read the article

  • Dynamic Data Connections

    - by Tim Dexter
    I have had a long running email thread running between Dan and David over at Valspar and myself. They have built some impressive connectivity between their in house apps and BIP using web services. The crux of their problem has been that they have multiple databases that need the same report executed against them. Not such an unusual request as I have spoken to two customers in the last month with the same situation. Of course, you could create a report against each data connection and just run or call the appropriate report. Not too bad if you have two or three data connections but more than that and it becomes a maintenance nightmare having to update queries or layouts. Ideally you want to have just a single report definition on the BIP server and to dynamically set the connection to be used at runtime based on the user or system that the user is in. A quick bit of digging and help from Shinji on the development team and I had an answer. Rather embarassingly, the solution has been around since the Oct 2010 rollup patch last year. Still, I grabbed the latest Jan 2011 patch - check out Note 797057.1 for the latest available patches. Once installed, I used the best web service testing tool I have yet to come across - SoapUI. Just point it at the WSDL and you can check out the available services and their parameters and then test them too. The XML packet has a new dynamic data source entry. You can set you own custom JDBC connection or just specify an existing data source name thats defined on the server. <pub:runReport> <pub:reportRequest> <pub:attributeFormat>xml</pub:attributeFormat> <pub:attributeTemplate>0</pub:attributeTemplate> <pub:byPassCache>true</pub:byPassCache> <pub:dynamicDataSource> <pub:JDBCDataSource> <pub:JDBCDriverClass></pub:JDBCDriverClass> <pub:JDBCDriverType></pub:JDBCDriverType> <pub:JDBCPassword></pub:JDBCPassword> <pub:JDBCURL></pub:JDBCURL> <pub:JDBCUserName></pub:JDBCUserName> <pub:dataSourceName>Conn1</pub:dataSourceName> </pub:JDBCDataSource> </pub:dynamicDataSource> <pub:reportAbsolutePath>/Test/Employee Report/Employee Report.xdo</pub:reportAbsolutePath> </pub:reportRequest> <pub:userID>Administrator</pub:userID> <pub:password>Administrator</pub:password> </pub:runReport> So I have Conn1 and Conn2 defined that are connections to different databases. I can just flip the name, make the WS call and get the appropriate dataset in my report. Just as an example, here's my web service call java code. Just a case of bringing in the BIP java libs to my java project. publicReportServiceService = new PublicReportServiceService(); PublicReportService publicReportService = publicReportServiceService.getPublicReportService_v11(); String userID = "Administrator"; String password = "Administrator"; ReportRequest rr = new ReportRequest(); rr.setAttributeFormat("xml"); rr.setAttributeTemplate("1"); rr.setByPassCache(true); rr.setReportAbsolutePath("/Test/Employee Report/Employee Report.xdo"); rr.setReportOutputPath("c:\\temp\\output.xml"); BIPDataSource bipds = new BIPDataSource(); JDBCDataSource jds = new JDBCDataSource(); jds.setDataSourceName("Conn1"); bipds.setJDBCDataSource(jds); rr.setDynamicDataSource(bipds); try { publicReportService.runReport(rr, userID, password); } catch (InvalidParametersException e) { e.printStackTrace(); } catch (AccessDeniedException e) { e.printStackTrace(); } catch (OperationFailedException e) { e.printStackTrace(); } } Note, Im no java whiz kid or whizzy old bloke, at least not unless Ive had a coffee. JDeveloper has a nice feature where you point it at the WSDL and it creates everything to support your calling code for you. Couple of things to remember: 1. When you call the service, remember to set the bypass the cache option. Forget it and much scratching of your head and taking my name in vain will ensue. 2. My demo actually hit the same database but used two users, one accessed the base tables another views with the same name. For far too long I thought the connection swapping was not working. I was getting the same results for both users until I realized I was specifying the schema name for the table/view in my query e.g. select * from EMP.EMPLOYEES. So remember to have a generic query that will depend entirely on the connection. Its a neat feature if you want to be able to switch connections and only define a single report and call it remotely. Now if you want the connection to be set dynamically based on the user and the report run via the user interface, thats going to be more tricky ... need to think about that one!

    Read the article

  • ASP.NET Web API and Simple Value Parameters from POSTed data

    - by Rick Strahl
    In testing out various features of Web API I've found a few oddities in the way that the serialization is handled. These are probably not super common but they may throw you for a loop. Here's what I found. Simple Parameters from Xml or JSON Content Web API makes it very easy to create action methods that accept parameters that are automatically parsed from XML or JSON request bodies. For example, you can send a JavaScript JSON object to the server and Web API happily deserializes it for you. This works just fine:public string ReturnAlbumInfo(Album album) { return album.AlbumName + " (" + album.YearReleased.ToString() + ")"; } However, if you have methods that accept simple parameter types like strings, dates, number etc., those methods don't receive their parameters from XML or JSON body by default and you may end up with failures. Take the following two very simple methods:public string ReturnString(string message) { return message; } public HttpResponseMessage ReturnDateTime(DateTime time) { return Request.CreateResponse<DateTime>(HttpStatusCode.OK, time); } The first one accepts a string and if called with a JSON string from the client like this:var client = new HttpClient(); var result = client.PostAsJsonAsync<string>(http://rasxps/AspNetWebApi/albums/rpc/ReturnString, "Hello World").Result; which results in a trace like this: POST http://rasxps/AspNetWebApi/albums/rpc/ReturnString HTTP/1.1Content-Type: application/json; charset=utf-8Host: rasxpsContent-Length: 13Expect: 100-continueConnection: Keep-Alive "Hello World" produces… wait for it: null. Sending a date in the same fashion:var client = new HttpClient(); var result = client.PostAsJsonAsync<DateTime>(http://rasxps/AspNetWebApi/albums/rpc/ReturnDateTime, new DateTime(2012, 1, 1)).Result; results in this trace: POST http://rasxps/AspNetWebApi/albums/rpc/ReturnDateTime HTTP/1.1Content-Type: application/json; charset=utf-8Host: rasxpsContent-Length: 30Expect: 100-continueConnection: Keep-Alive "\/Date(1325412000000-1000)\/" (yes still the ugly MS AJAX date, yuk! This will supposedly change by RTM with Json.net used for client serialization) produces an error response: The parameters dictionary contains a null entry for parameter 'time' of non-nullable type 'System.DateTime' for method 'System.Net.Http.HttpResponseMessage ReturnDateTime(System.DateTime)' in 'AspNetWebApi.Controllers.AlbumApiController'. An optional parameter must be a reference type, a nullable type, or be declared as an optional parameter. Basically any simple parameters are not parsed properly resulting in null being sent to the method. For the string the call doesn't fail, but for the non-nullable date it produces an error because the method can't handle a null value. This behavior is a bit unexpected to say the least, but there's a simple solution to make this work using an explicit [FromBody] attribute:public string ReturnString([FromBody] string message) andpublic HttpResponseMessage ReturnDateTime([FromBody] DateTime time) which explicitly instructs Web API to read the value from the body. UrlEncoded Form Variable Parsing Another similar issue I ran into is with POST Form Variable binding. Web API can retrieve parameters from the QueryString and Route Values but it doesn't explicitly map parameters from POST values either. Taking our same ReturnString function from earlier and posting a message POST variable like this:var formVars = new Dictionary<string,string>(); formVars.Add("message", "Some Value"); var content = new FormUrlEncodedContent(formVars); var client = new HttpClient(); var result = client.PostAsync(http://rasxps/AspNetWebApi/albums/rpc/ReturnString, content).Result; which produces this trace: POST http://rasxps/AspNetWebApi/albums/rpc/ReturnString HTTP/1.1Content-Type: application/x-www-form-urlencodedHost: rasxpsContent-Length: 18Expect: 100-continue message=Some+Value When calling ReturnString:public string ReturnString(string message) { return message; } unfortunately it does not map the message value to the message parameter. This sort of mapping unfortunately is not available in Web API. Web API does support binding to form variables but only as part of model binding, which binds object properties to the POST variables. Sending the same message as in the previous example you can use the following code to pick up POST variable data:public string ReturnMessageModel(MessageModel model) { return model.Message; } public class MessageModel { public string Message { get; set; }} Note that the model is bound and the message form variable is mapped to the Message property as would other variables to properties if there were more. This works but it's not very dynamic. There's no real easy way to retrieve form variables (or query string values for that matter) in Web API's Request object as far as I can discern. Well only if you consider this easy:public string ReturnString() { var formData = Request.Content.ReadAsAsync<FormDataCollection>().Result; return formData.Get("message"); } Oddly FormDataCollection does not allow for indexers to work so you have to use the .Get() method which is rather odd. If you're running under IIS/Cassini you can always resort to the old and trusty HttpContext access for request data:public string ReturnString() { return HttpContext.Current.Request.Form["message"]; } which works fine and is easier. It's kind of a bummer that HttpRequestMessage doesn't expose some sort of raw Request object that has access to dynamic data - given that it's meant to serve as a generic REST/HTTP API that seems like a crucial missing piece. I don't see any way to read query string values either. To me personally HttpContext works, since I don't see myself using self-hosted code much.© Rick Strahl, West Wind Technologies, 2005-2012Posted in Web Api   Tweet !function(d,s,id){var js,fjs=d.getElementsByTagName(s)[0];if(!d.getElementById(id)){js=d.createElement(s);js.id=id;js.src="//platform.twitter.com/widgets.js";fjs.parentNode.insertBefore(js,fjs);}}(document,"script","twitter-wjs"); (function() { var po = document.createElement('script'); po.type = 'text/javascript'; po.async = true; po.src = 'https://apis.google.com/js/plusone.js'; var s = document.getElementsByTagName('script')[0]; s.parentNode.insertBefore(po, s); })();

    Read the article

  • How big can my SharePoint 2010 installation be?

    - by Sahil Malik
    Ad:: SharePoint 2007 Training in .NET 3.5 technologies (more information). 3 years ago, I had published “How big can my SharePoint 2007 installation be?” Well, SharePoint 2010 has significant under the covers improvements. So, how big can your SharePoint 2010 installation be? There are three kinds of limits you should know about Hard limits that cannot be exceeded by design. Configurable that are, well configurable – but the default values are set for a pretty good reason, so if you need to tweak, plan and understand before you tweak. Soft limits, you can exceed them, but it is not recommended that you do. Before you read any of the limits, read these two important disclaimers - 1. The limit depends on what you’re doing. So, don’t take the below as gospel, the reality depends on your situation. 2. There are many additional considerations in planning your SharePoint solution scalability and performance, besides just the below. So with those in mind, here goes.   Hard Limits - Zones per web app 5 RBS NAS performance Time to first byte of any response from NAS must be less than 20 milliseconds List row size 8000 bytes driven by how SP stores list items internally Max file size 2GB (default is 50MB, configurable). RBS does not increase this limit. Search metadata properties 10,000 per item crawled (pretty damn high, you’ll never need to worry about it). Max # of concurrent in-memory enterprise content types 5000 per web server, per tenant Max # of external system connections 500 per web server PerformancePoint services using Excel services as a datasource No single query can fetch more than 1 million excel cells Office Web Apps Renders One doc per second, per CPU core, per Application server, limited to a maximum of 8 cores.   Configurable Limits - Row Size Limit 6, configurable via SPWebApplication.MaxListItemRowStorage property List view lookup 8 join operations per query Max number of list items that a single operation can process at one time in normal hours 5000 Configurable via SPWebApplication.MaxItemsPerThrottledOperation   Also you get a warning at 3000, which is configurable via SPWebApplication.MaxItemsPerThrottledOperationWarningLevel   In addition, throttle overrides can be requested, throttle overrides can be disabled, and time windows can be set when throttle is disabled. Max number of list items for administrators that a single operation can process at one time in normal hours 20000 Configurable via SPWebApplication.MaxItemsPerThrottledOperationOverride Enumerating subsites 2000 Word and Powerpoint co-authoring simultaneous editors 10 (Hard limit is 99). # of webparts on a page 25 Search Crawl DBs per search service app 10 Items per crawl db 25 million Search Keywords 200 per site collection. There is a max limit of 5000, which can then be modified by editing the web.config/client.config. Concurrent # of workflows on a content db 15. Workflows running in the timer service are not counted in this limit. Further workflows are queued. Can be configured via the Set-SPFarmConfig powershell commandlet. Number of events picked by the workflow timer job and delivered to workflows 100. You can increase this limit by running additional instances of the workflow timer service. Visio services file size 50MB Visio web drawing recalculation timeout 120 seconds Configurable via – Powershell commandlet Set-SPVisioPerformance Visio services minimum and maximum cache age for data connected diagrams 0 to 24 hours. Default is 60 minutes. Configurable via – Powershell commandlet Set-SPVisioPerformance   Soft Limits - Content Databases 300 per web app Application Pools 10 per web server Managed Paths 20 per web app Content Database Size 200GB per Content DB Size of 1 site collection 100GB # of sites in a site collection 250,000 Documents in a library 30 Million, with nesting. Depends heavily on type and usage and size of documents. Items 30 million. Depends heavily on usage of items. SPGroups one SPUser can be in 5000 Users in a site collection 2 million, depends on UI, nesting, containers and underlying user store AD Principals in a SPGroup 5000 SPGroups in a site collection 10000 Search Service Instances 20 Indexed Items in Search 100 million Crawl Log entries 100 million Search Alerts 1 million per search application Search Crawled Properties 1/2 million URL removals in search 100 removals per operation User Profiles 2 million per service application Social Tags 500 million per social database Comment on the article ....

    Read the article

  • How-to filter table filter input to only allow numeric input

    - by frank.nimphius
    In a previous ADF Code Corner post, I explained how to change the table filter behavior by intercepting the query condition in a query filter. See sample #30 at http://www.oracle.com/technetwork/developer-tools/adf/learnmore/index-101235.html In this OTN Harvest post I explain how to prevent users from providing invalid character entries as table filter criteria to avoid problems upon re-querying the table. In the example shown next, only numeric values are allowed for a table column filter. To create a table that allows data filtering, drag a View Object – or a data collection of a Web Service or JPA business service – from the DataControls panel and drop it as a table. Choose the Enable Filtering option in the Edit Table Columns dialog so the table renders with the column filter boxes displayed. The table filter fields are created using implicit af:inputText components that need to be customized for you to apply a custom filter input component, or to change the input behavior. To change the input filter, so only a defined set of input keys is allowed, you need to change the default filter field with your own af:inputText field to which you apply an af:clientListener tag that filters user keyboard entries. For this, in the Oracle JDeveloper visual editor, select the column which filter you want to change and expand the column node in the Oracle JDeveloper Structure Window. Part of the column definition is the Column facet node. Expand the facets so you see the filter facet entry. The filter facet is grayed out as there is no custom facet defined. In a next step, open theComponent Palette (ctrl+shift+P) and drag an Input Text component onto the facet. This demarks the first part in the filter customization. To make the custom filter component work, you need to map the af:inputText component value property to the ADF filter criteria that is exposed in the Expression Builder. Open the Expression Builder for the filter input component value property by clicking the arrow icon to its right. In the Expression Builder expand the JSP Objects | vs | filterCriteria node to select the attribute name represented by the table column. The vs entry is the name of a variable that is defined on the table and that grants you access to the table attributes. Now that the filter works as before – though using a custom filter input component – you can add the af:clientListener tag to your custom filter component – af:inputText – to call out to JavaScript when users type in the column filter field Point the client filter method property to a JavaScript function that you reference or add through using the af:resource tag and set the type property value to keyDown. <af:document id="d1">     <af:resource type="javascript" source="/js/filterHandler.js"/> … The filter definition looks as shown below <af:inputText label="Label 1" id="it1"                         value="#{vs.filterCriteria.Employe        <af:clientListener method="suppressCharacterInput"                                     type="keyDown"/> </af:inputText> The JavaScript code that you can use to either filter character inputs or numeric inputs is shown below. Just store this code in an external JavaScript (.js) file and reference it from the af:resource tag. //Allow numbers, cursor control keys and delete keys function suppressCharacterInput(evt) {     var _keyCode = evt.getKeyCode();     var _filterField = evt.getCurrentTarget();     var _oldValue = _filterField.getValue();     if (!((_keyCode < 57) ||(_keyCode > 96 && _keyCode < 105))) {         _filterField.setValue(_oldValue);         evt.cancel();     } } //Allow characters, cursor control keys and delete keys function suppressNumericInput(evt) {  var _keyCode = evt.getKeyCode();  var _filterField = evt.getCurrentTarget();  var _oldValue = _filterField.getValue();  //check for numbers  if ((_keyCode < 57 && _keyCode > 47) ||      (_keyCode > 96 && _keyCode < 105)){     _filterField.setValue(_oldValue);     evt.cancel();   } } But what if browsers don't allow JavaScript ? Don't worry about this. If browsers would not support JavaScript then ADF Faces as a whole would not work and you had a different problem.

    Read the article

  • How do I know what Version of BizTalk is on my server?

    - by Paula DiTallo
    Originally posted on: http://geekswithblogs.net/AskPaula/archive/2013/07/02/153324.aspxThere are 2 ways to do this, the first is to query the BizTalkDBVersion table:use [BizTalkMgmtDb]goSELECT DatabaseMajor, DatabaseMinor,ProductBuildNumber, ProductRevision FROM dbo.BizTalkDBVersion;  Here is a list of possible BizTalk versions (CUP = cumulative update package, SP = service pack) :BTS20043.0.4902.0BTS2004SP13.0.6070.0BTS2004SP2 3.0.7405.0BTS2006 3.5.1602.0BTS2006R23.6.1404.0BTS20093.8.368.0BTS2010    3.9.469.0BTS2010CUP13.9.522.2BTS2010CUP23.9.530.2BTS2010CUP33.9.542.2BTS2010CUP43.9.545.2BTS2010CUP53.9.556.2BTS2013    3.10.229.0The second way is to follow these steps:Click Start, click Run, type regedt32, and then click OK.Once the window is up, navigate to  HKEY_LOCAL_MACHINE,  then SOFTWARE, then Microsoft, then BizTalk Server, and finally open 3.0.This is what you should see:

    Read the article

< Previous Page | 579 580 581 582 583 584 585 586 587 588 589 590  | Next Page >