Search Results

Search found 21466 results on 859 pages for 'current buffer'.

Page 59/859 | < Previous Page | 55 56 57 58 59 60 61 62 63 64 65 66  | Next Page >

  • What is the current frequency of my processor (CPU-Z equivalent)?

    - by Anake
    Is there a ubuntu program like CPU-Z which will show me the actual frequency of my processor? I do a fair amount of scientific computing which leads to me running my programs for up to 10 hrs. To alleviate this problem a little I overclock my CPU. However I can't see what the actual clock of my processor from within ubuntu which means I either have to restart and look at the bios or load into windows. If there was an applet or command line command to find out this information it would be very helpful. Thanks for your help

    Read the article

  • Where to find current information on quality of released games as software products?

    - by Tom
    As a gamer, one thing I have learned I need to be savvy about is knowing whether SomeBigGame is actually unstable or otherwise problematic as a piece of software (riddled with invasive DRM products, only runs well on a particular video driver version, crashes on non-English-language systems, etc.). I know that game news media can sometimes be relied upon to report on some problems, but I doubt they bother to cover smaller or indie titles. An example: I've started playing Transformice on Kongregate, and I'm considering installing the downloadable client (it is an online multiplayer game). The part of me that cares about data privacy and maintaining a clean-and-healthy PC wants to know whether there is a place I can check to find out more about a title-as-software than "it is not a literal virus." Put another way: where would you not want to see your game receive lots of attention?

    Read the article

  • What is the current state of apple device (iPhone, iPod, etc.) support?

    - by BullfrogBlues
    What ubuntu applications provide support? (guides, how to's, status) Also, specifically, details on support for syncing music to iPhone's and iPod's with the latest OS version, as of writing iOS 5: Can you sync music to apple devices using iOS5? (iPhone & iPod) What applications allow you to do this and how? (guides, how to's, status) What has already been established is: Apple does not support Linux and has no plans to. libimobiledevice seems to provide some support but does not support syncing music with devices using iOS5. (I can't test libmobiledevice with anything other iOS5, so I can't provide details on how that works)

    Read the article

  • Quit job for another but current employer doesn't want to lose me. Would it be a bad idea to stay?

    - by Confused
    So I've handed in my notice at my current job as I've been offered a job at another company. However, my current employer doesn't want to lose me and they want to know what I want to stay. I mostly enjoy working there so I'd be open to negiotiation. The new job was an unexpected opportunity that presented itself. Such things I'd be looking for are: Better computers for developers Opportunity to work from home occasionally Improved internet access (e.g. able to download software, no keyword blocking) Chance to work on other technologies than my primary (we do have projects on other technologies) Pay increase (though this isn't my primary motivation) I found out that some of these were already in progress when I handed in my notice :( Is it ever a good idea to remain at a company after you've resigned? What if they meet all my conditions and alter my contract accordingly? Will I burn my bridges at the new company (I've already told them I'd accept their offer)? Update: Thanks for the answers. Quite a mixed bag which was interesting. Anyway, just so you know, I've chosen to stay at my current company. So far, it definately feels like the right decision. Guess I won't know for a few months whether is was though.

    Read the article

  • If timestamp is deprecated, why do none of the current db tools support rowversion?

    Perhaps the title of this blog post will suffice, but I just wanted to highlight this problem. If you were to look up the timestamp data type in the SQL Server 2008 documentation, this is waht you will find within the topic article: The timestamp syntax is deprecated. This feature will be removed in a future version of Microsoft SQL Server. Avoid using this feature in new development work, and plan to modify applications that currently use this feature. Its been there for quite some time. The...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • How to make QCombobox painting item delegate for it's current Item? (Qt 4)

    - by r4nj33t
    QCombobox set Item delegate not painting for current Item.. I am trying to create a combo box showing different line types (Solid, Dotted, Dash etc). Currently i am setting item delegate for its content so as to draw/paint line type instead of displaying names. All line types are drawing currectly but as soon as i am selecting any line type from the combobox, the current index of combo box is displaying just the line name and not painting it. How can i make it paint the selected line type on the current combo box index?

    Read the article

  • MYSQL - Selecting a specific date range to get "current" popular screensavers.

    - by Joe
    Let's say I have a screensaver website. I want to display the CURRENT top 100 screensavers on the front page of the website. What I mean is, "RECENT" top 100 screensavers. What would be an example query to do this? My current one is: SELECT * FROM tbl_screensavers WHERE WEEK(tbl_screensavers.DateAdded) = WEEK('".date("Y-m-d H:i:s",strtotime("-1 week"))."') ORDER BY tbl_screensavers.ViewsCount, tbl_screensavers.DateAdded This will select the most viewed ("tbl_screensavers.ViewsCount") screensavers that were added ("tbl_screensavers.DateAdded") in the last week. However, in some cases there are no screensavers, or less than 100 screensavers, submitted in that week. So, how can I perform a query which would select "RECENT" top 100 screensavers? Hopefully you have an idea of what I'm try to accomplish when I say "RECENT" or "CURRENT" top screensavers. -- aka. the most viewed, recently - not the most viewed, all-time.

    Read the article

  • How to detect when video is buffering?

    - by Leon
    Hi guys, my question today deals with Flash AS3 video buffering. (Streaming or Progressive) I want to be able to detect when the video is being buffered, so I can display some sort of animation letting the user know to wait just a little longer. Currently my video will start up, hold on frame 1 for 3-4 secs then play. Kinda giving the impression that the video is paused or broken :( Update Thanks to iandisme I believe I'm faced in the right direction now. NetStatusEvent from livedocs. It seems to me that the key status to be working in is "NetStream.Buffer.Empty" so I added some code in there to see if this would trigger my animation or a trace statement. No luck yet, however when the Buffer is full it will trigger my code :/ Maybe my video is always somewhere between Buffer.Empty and Buffer.Full that's why it won't trigger any code when I test case for Buffer.Empty? Current Code public function netStatusHandler(event:NetStatusEvent):void { // handles net status events switch (event.info.code) { case "NetStream.Buffer.Empty": trace("¤¤¤ Buffering!"); //<- never traces addChild(bufferLoop); //<- doesn't execute break; case "NetStream.Buffer.Full": trace("¤¤¤ FULL!"); //<- trace works here removeChild(bufferLoop); //<- so does any other code break; case "NetStream.Buffer.Flush": trace("¤¤¤ FLUSH!"); //Not sure if this is important break } }

    Read the article

  • Ruby Design Problem for SQL Bulk Inserter

    - by crunchyt
    This is a Ruby design problem. How can I make a reusable flat file parser that can perform different data scrubbing operations per call, return the emitted results from each scrubbing operation to the caller and perform bulk SQL insertions? Now, before anyone gets narky/concerned, I have written this code already in a very unDRY fashion. Which is why I am asking any Ruby rockstars our there for some assitance. Basically, everytime I want to perform this logic, I create two nested loops, with custom processing in between, buffer each processed line to an array, and output to the DB as a bulk insert when the buffer size limit is reached. Although I have written lots of helpers, the main pattern is being copy pasted everytime. Not very DRY! Here is a Ruby/Pseudo code example of what I am repeating. lines_from_file.each do |line| line.match(/some regex/).each do |sub_str| # Process substring into useful format # EG1: Simple gsub() call # EG2: Custom function call to do complex scrubbing # and matching, emitting results to array # EG3: Loop to match opening/closing/nested brackets # or other delimiters and emit results to array end # Add processed lines to a buffer as SQL insert statement @buffer << PREPARED INSERT STATEMENT # Flush buffer when "buffer size limit reached" or "end of file" if sql_buffer_full || last_line_reached @dbc.insert(SQL INSERTS FROM BUFFER) @buffer = nil end end I am familiar with Proc/Lambda functions. However, because I want to pass two separate procs to the one function, I am not sure how to proceed. I have some idea about how to solve this, but I would really like to see what the real Rubyists suggest? Over to you. Thanks in advance :D

    Read the article

  • Why is HttpContext.Current.Session available in HttpModule but not in Response.Filter?

    - by Abtin Forouzandeh
    I have written an HttpModule that adds a response filter. The filter is capturing page output and storing it in a session variable. I am able to access HttpContext.Current.Session in my HttpModule. The HttpModule is handling the PostAcquireRequestState event. I am still able to access HttpContext.Current.Session in the PostAcquireRequestState event. I am adding a custom stream that inherits from Stream to Response.Filter HttpContext.Current.Session is null when accessed from the Stream.Write method. Everything worked fine when using an InProc SessionState. However, I now must use StateServer. Using StateServer, the code is now broken. Any ideas?

    Read the article

  • Is There a Better Way to Feed Different Parameters into Functions with If-Statements?

    - by FlowofSoul
    I've been teaching myself Python for a little while now, and I've never programmed before. I just wrote a basic backup program that writes out the progress of each individual file while it is copying. I wrote a function that determines buffer size so that smaller files are copied with a smaller buffer, and bigger files are copied with a bigger buffer. The way I have the code set up now doesn't seem very efficient, as there is an if loop that then leads to another if loops, creating four options, and they all just call the same function with different parameters. import os import sys def smartcopy(filestocopy, dest_path, show_progress = False): """Determines what buffer size to use with copy() Setting show_progress to True calls back display_progress()""" #filestocopy is a list of dictionaries for the files needed to be copied #dictionaries are used as the fullpath, st_mtime, and size are needed if len(filestocopy.keys()) == 0: return None #Determines average file size for which buffer to use average_size = 0 for key in filestocopy.keys(): average_size += int(filestocopy[key]['size']) average_size = average_size/len(filestocopy.keys()) #Smaller buffer for smaller files if average_size < 1024*10000: #Buffer sizes determined by informal tests on my laptop if show_progress: for key in filestocopy.keys(): #dest_path+key is the destination path, as the key is the relative path #and the dest_path is the top level folder copy(filestocopy[key]['fullpath'], dest_path+key, callback = lambda pos, total: display_progress(pos, total, key)) else: for key in filestocopy.keys(): copy(filestocopy[key]['fullpath'], dest_path+key, callback = None) #Bigger buffer for bigger files else: if show_progress: for key in filestocopy.keys(): copy(filestocopy[key]['fullpath'], dest_path+key, 1024*2600, callback = lambda pos, total: display_progress(pos, total, key)) else: for key in filestocopy.keys(): copy(filestocopy[key]['fullpath'], dest_path+key, 1024*2600) def display_progress(pos, total, filename): percent = round(float(pos)/float(total)*100,2) if percent <= 100: sys.stdout.write(filename + ' - ' + str(percent)+'% \r') else: percent = 100 sys.stdout.write(filename + ' - Completed \n') Is there a better way to accomplish what I'm doing? Sorry if the code is commented poorly or hard to follow. I didn't want to ask someone to read through all 120 lines of my poorly written code, so I just isolated the two functions. Thanks for any help.

    Read the article

  • How can I find the current edit slide in PowerPoint?

    - by mj2008
    I'm writing an add-in for PowerPoint, and want to get the text from the current slide in the editing window. The following works, but only when the slide is selected in the slide selector pane. xSelection := PowerPointApp.ActiveWindow.Selection; if xSelection.Type = ppSelectionSlides then begin xSlide := xSelection.SlideRange.Item(1); end; I've been chasing my tail at MSDN trying to work out what the correct way to find out the current slide is. The DocumentWindow doesn't seem to have a current slide.

    Read the article

  • When parsing XML with jquery, how can we pass the current node from within each() to another functio

    - by Johusa
    Say we have an XML document with many book nodes... When parsing XML with jquery, how can i pass the current node from each() iteration to another function that will do some stuff until something is reached and then go back to the previous function (passing along the current node from this function back to the first function)? Here something more descriptive (this is just an example out of my head, not accurate): function MyParser(x1,x2,dom) { // if i am called by anotherFunction(thisNode) proceed from the passed node dom.find('book').each(function() { var Letter = thisNode.find(author).charAt(0); if(x1 == Letter) { // print everything till the next letter (x2) anotherFunction(thisNode) } } } function anotherFunction(x2,thisNode) { //continue parsing here until you reached x2 //when x2 is reached, return to previous function passing again the current node }

    Read the article

  • What used the linux memory? Low cache, low buffer, not a VM

    - by Jason
    First of all, yes, I have read LinuxAteMyRAM, which doesn't explain my situation. # free -tm total used free shared buffers cached Mem: 48149 43948 4200 0 4 75 -/+ buffers/cache: 43868 4280 Swap: 38287 0 38287 Total: 86436 43948 42488 # As shown above, the -/+ buffers/cache: line shows indicates the used memory rate is very high. However, from output of top, I don't see any process used more than 100MB of memory. So, what used the memory? PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 28078 root 18 0 327m 92m 10m S 0 0.2 0:25.06 java 31416 root 16 0 250m 28m 20m S 0 0.1 25:54.59 ResourceMonitor 21598 root -98 0 26552 25m 8316 S 0 0.1 80:49.54 had 24580 root 16 0 24152 10m 760 S 0 0.0 1:25.87 rsyncd 4956 root 16 0 62588 10m 3132 S 0 0.0 12:36.54 vxconfigd 26703 root 16 0 139m 7120 2900 S 1 0.0 4359:39 hrmonitor 21873 root 15 0 18764 4684 2152 S 0 0.0 30:07.56 MountAgent 21883 root 15 0 13736 4280 2172 S 0 0.0 25:25.09 SybaseAgent 21878 root 15 0 18548 4172 2000 S 0 0.0 52:33.46 NICAgent 21887 root 15 0 12660 4056 2168 S 0 0.0 25:07.80 SybaseBkAgent 17798 root 25 0 10652 4048 1160 S 0 0.0 0:00.04 vxconfigbackupd This is an x86_64 machine (not a common-brand server) running x84_64 Linux, not a container in a virtual machine. Kernel (uname -a): Linux 2.6.16.60-0.99.1-smp #1 SMP Fri Oct 12 14:24:23 UTC 2012 x86_64 x86_64 x86_64 GNU/Linux Content of /proc/meminfo: MemTotal: 49304856 kB MemFree: 4066708 kB Buffers: 35688 kB Cached: 132588 kB SwapCached: 0 kB Active: 26536644 kB Inactive: 17296272 kB HighTotal: 0 kB HighFree: 0 kB LowTotal: 49304856 kB LowFree: 4066708 kB SwapTotal: 39206624 kB SwapFree: 39206528 kB Dirty: 200 kB Writeback: 0 kB AnonPages: 249592 kB Mapped: 52712 kB Slab: 1049464 kB CommitLimit: 63859052 kB Committed_AS: 659384 kB PageTables: 3412 kB VmallocTotal: 34359738367 kB VmallocUsed: 478420 kB VmallocChunk: 34359259695 kB HugePages_Total: 0 HugePages_Free: 0 HugePages_Rsvd: 0 Hugepagesize: 2048 kB df reports no large consumption of memory from tmpfs filesystems.

    Read the article

  • Is current SATA 6 gb/s equipment simply unreliable?

    - by korkman
    I have a 45-disk array of Seagate Barracuda 3 TB ST3000DM001 (yes these are desktop drives I'm aware of that) in a Supermicro sc847 JBOD, connected via LSI 9285. I have found a solution for the problem description below by reducing speed via MegaCli -PhySetLinkSpeed -phy0 2 -a0; for i in $(seq 48); do MegaCli -PhySetLinkSpeed -phy${i} 2 -a0; done and rebooting. The question remains: Is this typical for current 6 gb/s equipment? Is this the sad state of SATA storage? Or is some of my equipment (the sff-8088 cables come to mind) bad? The Problem was: Synchronizing HW RAID-6, disks kept offlining. Fetching SMART values reveiled that those which offlined did not increase powered-on hours anymore. That is, their firmware (CC4C) seems to crash. Digging into the matter by switching to Software RAID-6, with the disks passed-through, I got tons of kernel messages scattered across all disks, with 6 gb/s: sd 0:0:9:0: [sdb] Sense Key : No Sense [current] Info fld=0x0 sd 0:0:9:0: [sdb] Add. Sense: No additional sense information And finally, when a disk offlines: megasas: [ 5]waiting for 160 commands to complete ... megasas: [35]waiting for 159 commands to complete ... megasas: [155]waiting for 156 commands to complete ... megaraid_sas: pending commands remain after waiting, will reset adapter. Ugly controller reset here, then minutes later: megaraid_sas: Reset successful. sd 0:0:28:0: Device offlined - not ready after error recovery ... sd 0:0:28:0: [sdu] Unhandled error code sd 0:0:28:0: [sdu] Result: hostbyte=DID_ERROR driverbyte=DRIVER_OK sd 0:0:28:0: [sdu] CDB: Read(10): 28 00 23 21 2f 40 00 00 70 00 sd 0:0:28:0: [sdu] killing request Reduced speed to 3 gb/s like written above, all problems vanished.

    Read the article

  • Outlook error-'Can't open e-mail folders.You must connect to Exchange w/ current profile before you can sync folders w/ your Outlook data file'

    - by Emilio
    Note that the error message I put in the title of this question is abbreviated. The actual error message is below. I have an Exchange account and using Outlook 2010 as the client. I run in Cached Exchange Mode and have an .OST file locally. Recently I uninstalled and reinstalled office. I set up a new mail profile when prompted by Outlook 2010 upon first execution of the program. In my initial attempt, I pointed the data file at my existing OST file. In my second attempt, I had Outlook create a fresh empty file. In both cases I'm getting the error 'Cannot open your default e-mail folders. You must connect to Microsoft Exchange with the current profile before you can synchronize your folders with your Outlook data file (.ost).', also shown in this screenshot -- http://drop.io/4rc9v9o/asset/outlook-error-png. I don't know how to connect with the current profile - that's what I thought I did when I created a new .OST file? I've had this problem for several days so my OST file is now out of date. Once I get things running I obviously want my active mailbox to update the OST, not the other way around.

    Read the article

  • Can Current Backflow from Powered Hub's Adapter & cause PC Damage?

    - by SuperUserMan
    Getting this short: Can current flow from a powered USB hub's power adapter (lying 10 Meter away) back to computer via usb port and cause damage to Computer components like mobo, etc? What should be my concerns? Using a 2 Amp 5V Power adapter to power a 10m Long Active Repeater USB extension cable with 4 port HUB & plugging into PC's Front port, causes PC Chassis fan to keep running (thought slower than regular speed) Front Chassis HDD & power LED to turn on (though bit dim) may be other things which i cant detect/see at chip level, in motherboard?? All this even after PC is shut down (bit scary) More detail (in case still want to read): To run 4 High power (needing 450 mAmps) Wifi Adapters, far away from PC, Bought Active Repeater USB Extension Cable with 4 Ports & power port at far end http://www.ebay.com/itm/33FT-USB-2-0-Male-to-Female-Extension-Cable-Hub-Splitter-Adapter-with-4-USB-Port-/390846115254 Then added a locally bought 2 Amp 240V AC to 5V DC Power Adapter and plugged into USB hub which is a part of & situated at far end of a 10 Meter Active Repeater usb extension cable. Even 4 Wifi Adapters run fine (appear to) using this setup, but running chassis fan, dimly lighted Power & HDD LED, even when PC is switched off is bit scary and surely mean 5V & some current is flowing all though that 10 meter extension cable into my USB port & powering stuff. Can this cause damage? and what should be my concerns. Of course I can't switch off the power adapter (lying 10 meters away from PC) every time I switch off my PC to prevent this.

    Read the article

  • How to access original files from before a symlink gets updated, which have since been moved to another dir

    - by Luke Cousins
    We have a website and our deployment process goes somewhat like the following (with lots of irrelevant steps excluded) echo "Remove previous, if it exists, we don't need that anymore" rm -rf /home/[XXX]/php_code/previous echo "Create the current dir if it doesn't exist (just in case this is the first deploy to this server)" mkdir -p /home/[XXX]/php_code/current echo "Create the var_www dir if it doesn't exist (just in case this is the first deploy to this server)" mkdir -p /home/[XXX]/var_www echo "Copy current to previous so we can use temporarily" cp -R /home/[XXX]/php_code/current/* /home/[XXX]/php_code/previous/ echo "Atomically swap the symbolic link to use previous instead of current" ln -s /home/[XXX]/php_code/previous /home/[XXX]/var_www/live_tmp && mv -Tf /home/[XXX]/var_www/live_tmp /home/[XXX]/var_www/live # Rsync latest code into the current dir, code not shown here echo "Atomically swap the symbolic link to use current instead of previous" ln -s /home/[XXX]/php_code/current /home/[XXX]/var_www/live_tmp && mv -Tf /home/[XXX]/var_www/live_tmp /home/[XXX]/var_www/live The problem we are having and would like help with is that, the first thing any website page load does is work out the base dir of the application and define it as a constant (we use PHP). If then during that page load a deployment occurs, the system tries to include() a file using the original full path and will get the new version of that file. We need it to get the old one from the old dir which has now moved as in: System starts page load and determines SYSTEM_ROOT_PATH constant to be /home/[XXX]/var_www/live or by using PHP's realpath() it could be /home/[XXX]/php_code/current. Symlink for /home/[XXX]/var_www/live get updated to point to /home/[XXX]/php_code/previous instead of /home/[XXX]/php_code/current where it did originally. System tries to load /home/[XXX]/var_www/live/something.php and gets /home/[XXX]/php_code/current/something.php instead of /home/[XXX]/php_code/previous/something.php I'm sorry if that is not explained very well. I'd really appreciate some ideas on how to get around this problem if someone can. Thank you.

    Read the article

  • processing of Group Policy failed only on 2008 Servers and Name Resolution failure on the current domain controller

    - by Ken Wolfrom
    Spent last 3 months doing a upgrade from 2003 domain to a 2008R2 domain. our last DC was rebuilt (5 total) and brought up on line. After it was put on line we have some 2008 and 2008R2 servers (10 now) getting these errors in the event logs. ERRORS Description: The processing of Group Policy failed. Windows could not resolve the user name. This could be caused by one of more of the following: a) Name Resolution failure on the current domain controller. b) Active Directory Replication Latency (an account created on another domain controller has not replicated to the current domain controller).\ Can duplicate this if we drop to command prompt and run GPUPDATE manually When our users attempt to do a \directory\shared access to shared drive on an affected server get this error.– “THERE ARE CURRETLY NO LOGON SERVER AVAIALBE TO SERICE THE LOGON REQUEST. This is only affecting the 2008 OS and it is a random set of abotu 10 servers out of some 30 with this OS. The Services on the machines are running Ok and login. Able to log in with domain/user to the consoles and via RDP. WE can log onto an affected machine, and can get to the \domainname\sysvol and can see the GPO's Have checked the replication topology of the domain and it states all servers can replicate with no errrors. We went back to the last DC, demoted it, removed DNS and then removed it from the domain and waited 24 hours and issue still persist. Picked one server, removed it from domain, reboooted, and added back to domain with no problems, but still has this behavior. bottom line is we have some servers that the domain will not let any UDP/client server apps or GPO's process ,but the tcp related items seeme to work fine, http, tcp calls, sql and oracle dbs's connect and process. Any inputs on some possible reasons for this issue and fixes. It is only affecting the 2008 servers on a 2008R2 domain.

    Read the article

  • Why does async BeginReceiveFrom never time out on a raw socket?

    - by James Hugard
    Writing an asynchronous Ping using Raw Sockets in F#, to enable parallel requests using as few threads as possible. Not using "System.Net.NetworkInformation.Ping", because it appears to allocate one thread per request. Am also interested in using F# async workflows. The synchronous version below correctly times out when the target host does not exist/respond, but the asynchronous version hangs. Both work when the host does respond. Not sure if this is a .NET issue, or an F# one... Any ideas? (note: the process must run as Admin to allow Raw Socket access) This throws a timeout: let result = Ping.Ping ( IPAddress.Parse( "192.168.33.22" ), 1000 ) However, this hangs: let result = Ping.AsyncPing ( IPAddress.Parse( "192.168.33.22" ), 1000 ) |> Async.RunSynchronously Here's the code... module Ping open System open System.Net open System.Net.Sockets open System.Threading //---- ICMP Packet Classes type IcmpMessage (t : byte) = let mutable m_type = t let mutable m_code = 0uy let mutable m_checksum = 0us member this.Type with get() = m_type member this.Code with get() = m_code member this.Checksum = m_checksum abstract Bytes : byte array default this.Bytes with get() = [| m_type m_code byte(m_checksum) byte(m_checksum >>> 8) |] member this.GetChecksum() = let mutable sum = 0ul let bytes = this.Bytes let mutable i = 0 // Sum up uint16s while i < bytes.Length - 1 do sum <- sum + uint32(BitConverter.ToUInt16( bytes, i )) i <- i + 2 // Add in last byte, if an odd size buffer if i <> bytes.Length then sum <- sum + uint32(bytes.[i]) // Shuffle the bits sum <- (sum >>> 16) + (sum &&& 0xFFFFul) sum <- sum + (sum >>> 16) sum <- ~~~sum uint16(sum) member this.UpdateChecksum() = m_checksum <- this.GetChecksum() type InformationMessage (t : byte) = inherit IcmpMessage(t) let mutable m_identifier = 0us let mutable m_sequenceNumber = 0us member this.Identifier = m_identifier member this.SequenceNumber = m_sequenceNumber override this.Bytes with get() = Array.append (base.Bytes) [| byte(m_identifier) byte(m_identifier >>> 8) byte(m_sequenceNumber) byte(m_sequenceNumber >>> 8) |] type EchoMessage() = inherit InformationMessage( 8uy ) let mutable m_data = Array.create 32 32uy do base.UpdateChecksum() member this.Data with get() = m_data and set(d) = m_data <- d this.UpdateChecksum() override this.Bytes with get() = Array.append (base.Bytes) (this.Data) //---- Synchronous Ping let Ping (host : IPAddress, timeout : int ) = let mutable ep = new IPEndPoint( host, 0 ) let socket = new Socket( AddressFamily.InterNetwork, SocketType.Raw, ProtocolType.Icmp ) socket.SetSocketOption( SocketOptionLevel.Socket, SocketOptionName.SendTimeout, timeout ) socket.SetSocketOption( SocketOptionLevel.Socket, SocketOptionName.ReceiveTimeout, timeout ) let packet = EchoMessage() let mutable buffer = packet.Bytes try if socket.SendTo( buffer, ep ) <= 0 then raise (SocketException()) buffer <- Array.create (buffer.Length + 20) 0uy let mutable epr = ep :> EndPoint if socket.ReceiveFrom( buffer, &epr ) <= 0 then raise (SocketException()) finally socket.Close() buffer //---- Entensions to the F# Async class to allow up to 5 paramters (not just 3) type Async with static member FromBeginEnd(arg1,arg2,arg3,arg4,beginAction,endAction,?cancelAction): Async<'T> = Async.FromBeginEnd((fun (iar,state) -> beginAction(arg1,arg2,arg3,arg4,iar,state)), endAction, ?cancelAction=cancelAction) static member FromBeginEnd(arg1,arg2,arg3,arg4,arg5,beginAction,endAction,?cancelAction): Async<'T> = Async.FromBeginEnd((fun (iar,state) -> beginAction(arg1,arg2,arg3,arg4,arg5,iar,state)), endAction, ?cancelAction=cancelAction) //---- Extensions to the Socket class to provide async SendTo and ReceiveFrom type System.Net.Sockets.Socket with member this.AsyncSendTo( buffer, offset, size, socketFlags, remoteEP ) = Async.FromBeginEnd( buffer, offset, size, socketFlags, remoteEP, this.BeginSendTo, this.EndSendTo ) member this.AsyncReceiveFrom( buffer, offset, size, socketFlags, remoteEP ) = Async.FromBeginEnd( buffer, offset, size, socketFlags, remoteEP, this.BeginReceiveFrom, (fun asyncResult -> this.EndReceiveFrom(asyncResult, remoteEP) ) ) //---- Asynchronous Ping let AsyncPing (host : IPAddress, timeout : int ) = async { let ep = IPEndPoint( host, 0 ) use socket = new Socket( AddressFamily.InterNetwork, SocketType.Raw, ProtocolType.Icmp ) socket.SetSocketOption( SocketOptionLevel.Socket, SocketOptionName.SendTimeout, timeout ) socket.SetSocketOption( SocketOptionLevel.Socket, SocketOptionName.ReceiveTimeout, timeout ) let packet = EchoMessage() let outbuffer = packet.Bytes try let! result = socket.AsyncSendTo( outbuffer, 0, outbuffer.Length, SocketFlags.None, ep ) if result <= 0 then raise (SocketException()) let epr = ref (ep :> EndPoint) let inbuffer = Array.create (outbuffer.Length + 256) 0uy let! result = socket.AsyncReceiveFrom( inbuffer, 0, inbuffer.Length, SocketFlags.None, epr ) if result <= 0 then raise (SocketException()) return inbuffer finally socket.Close() }

    Read the article

  • How to detect a timeout when using asynchronous Socket.BeginReceive?

    - by James Hugard
    Writing an asynchronous Ping using Raw Sockets in F#, to enable parallel requests using as few threads as possible. Not using "System.Net.NetworkInformation.Ping", because it appears to allocate one thread per request. Am also interested in using F# async workflows. The synchronous version below correctly times out when the target host does not exist/respond, but the asynchronous version hangs. Both work when the host does respond. Not sure if this is a .NET issue, or an F# one... Any ideas? (note: the process must run as Admin to allow Raw Socket access) This throws a timeout: let result = Ping.Ping ( IPAddress.Parse( "192.168.33.22" ), 1000 ) However, this hangs: let result = Ping.AsyncPing ( IPAddress.Parse( "192.168.33.22" ), 1000 ) |> Async.RunSynchronously Here's the code... module Ping open System open System.Net open System.Net.Sockets open System.Threading //---- ICMP Packet Classes type IcmpMessage (t : byte) = let mutable m_type = t let mutable m_code = 0uy let mutable m_checksum = 0us member this.Type with get() = m_type member this.Code with get() = m_code member this.Checksum = m_checksum abstract Bytes : byte array default this.Bytes with get() = [| m_type m_code byte(m_checksum) byte(m_checksum >>> 8) |] member this.GetChecksum() = let mutable sum = 0ul let bytes = this.Bytes let mutable i = 0 // Sum up uint16s while i < bytes.Length - 1 do sum <- sum + uint32(BitConverter.ToUInt16( bytes, i )) i <- i + 2 // Add in last byte, if an odd size buffer if i <> bytes.Length then sum <- sum + uint32(bytes.[i]) // Shuffle the bits sum <- (sum >>> 16) + (sum &&& 0xFFFFul) sum <- sum + (sum >>> 16) sum <- ~~~sum uint16(sum) member this.UpdateChecksum() = m_checksum <- this.GetChecksum() type InformationMessage (t : byte) = inherit IcmpMessage(t) let mutable m_identifier = 0us let mutable m_sequenceNumber = 0us member this.Identifier = m_identifier member this.SequenceNumber = m_sequenceNumber override this.Bytes with get() = Array.append (base.Bytes) [| byte(m_identifier) byte(m_identifier >>> 8) byte(m_sequenceNumber) byte(m_sequenceNumber >>> 8) |] type EchoMessage() = inherit InformationMessage( 8uy ) let mutable m_data = Array.create 32 32uy do base.UpdateChecksum() member this.Data with get() = m_data and set(d) = m_data <- d this.UpdateChecksum() override this.Bytes with get() = Array.append (base.Bytes) (this.Data) //---- Synchronous Ping let Ping (host : IPAddress, timeout : int ) = let mutable ep = new IPEndPoint( host, 0 ) let socket = new Socket( AddressFamily.InterNetwork, SocketType.Raw, ProtocolType.Icmp ) socket.SetSocketOption( SocketOptionLevel.Socket, SocketOptionName.SendTimeout, timeout ) socket.SetSocketOption( SocketOptionLevel.Socket, SocketOptionName.ReceiveTimeout, timeout ) let packet = EchoMessage() let mutable buffer = packet.Bytes try if socket.SendTo( buffer, ep ) <= 0 then raise (SocketException()) buffer <- Array.create (buffer.Length + 20) 0uy let mutable epr = ep :> EndPoint if socket.ReceiveFrom( buffer, &epr ) <= 0 then raise (SocketException()) finally socket.Close() buffer //---- Entensions to the F# Async class to allow up to 5 paramters (not just 3) type Async with static member FromBeginEnd(arg1,arg2,arg3,arg4,beginAction,endAction,?cancelAction): Async<'T> = Async.FromBeginEnd((fun (iar,state) -> beginAction(arg1,arg2,arg3,arg4,iar,state)), endAction, ?cancelAction=cancelAction) static member FromBeginEnd(arg1,arg2,arg3,arg4,arg5,beginAction,endAction,?cancelAction): Async<'T> = Async.FromBeginEnd((fun (iar,state) -> beginAction(arg1,arg2,arg3,arg4,arg5,iar,state)), endAction, ?cancelAction=cancelAction) //---- Extensions to the Socket class to provide async SendTo and ReceiveFrom type System.Net.Sockets.Socket with member this.AsyncSendTo( buffer, offset, size, socketFlags, remoteEP ) = Async.FromBeginEnd( buffer, offset, size, socketFlags, remoteEP, this.BeginSendTo, this.EndSendTo ) member this.AsyncReceiveFrom( buffer, offset, size, socketFlags, remoteEP ) = Async.FromBeginEnd( buffer, offset, size, socketFlags, remoteEP, this.BeginReceiveFrom, (fun asyncResult -> this.EndReceiveFrom(asyncResult, remoteEP) ) ) //---- Asynchronous Ping let AsyncPing (host : IPAddress, timeout : int ) = async { let ep = IPEndPoint( host, 0 ) use socket = new Socket( AddressFamily.InterNetwork, SocketType.Raw, ProtocolType.Icmp ) socket.SetSocketOption( SocketOptionLevel.Socket, SocketOptionName.SendTimeout, timeout ) socket.SetSocketOption( SocketOptionLevel.Socket, SocketOptionName.ReceiveTimeout, timeout ) let packet = EchoMessage() let outbuffer = packet.Bytes try let! result = socket.AsyncSendTo( outbuffer, 0, outbuffer.Length, SocketFlags.None, ep ) if result <= 0 then raise (SocketException()) let epr = ref (ep :> EndPoint) let inbuffer = Array.create (outbuffer.Length + 256) 0uy let! result = socket.AsyncReceiveFrom( inbuffer, 0, inbuffer.Length, SocketFlags.None, epr ) if result <= 0 then raise (SocketException()) return inbuffer finally socket.Close() }

    Read the article

  • Why does BeginReceiveFrom never time out?

    - by James Hugard
    I am writing an asynchronous Ping using Raw Sockets in F#, to enable parallel requests using as few threads as possible ("System.Net.NetworkInformation.Ping" appears to use one thread per request, but have not tested this... also am interested in using F# async workflows). The synchronous version below correctly times out when the target host does not exist/respond, but the asynchronous version hangs. Both work when the host does respond... Any ideas? (note: the process must run as Admin for this code to work) This throws a timeout: let result = Ping.Ping ( IPAddress.Parse( "192.168.33.22" ), 1000 ) However, this hangs: let result = Ping.PingAsync ( IPAddress.Parse( "192.168.33.22" ), 1000 ) |> Async.RunSynchronously Here's the code... module Ping open System open System.Net open System.Net.Sockets open System.Threading //---- ICMP Packet Classes type IcmpMessage (t : byte) = let mutable m_type = t let mutable m_code = 0uy let mutable m_checksum = 0us member this.Type with get() = m_type member this.Code with get() = m_code member this.Checksum = m_checksum abstract Bytes : byte array default this.Bytes with get() = [| m_type m_code byte(m_checksum) byte(m_checksum >>> 8) |] member this.GetChecksum() = let mutable sum = 0ul let bytes = this.Bytes let mutable i = 0 // Sum up uint16s while i < bytes.Length - 1 do sum <- sum + uint32(BitConverter.ToUInt16( bytes, i )) i <- i + 2 // Add in last byte, if an odd size buffer if i <> bytes.Length then sum <- sum + uint32(bytes.[i]) // Shuffle the bits sum <- (sum >>> 16) + (sum &&& 0xFFFFul) sum <- sum + (sum >>> 16) sum <- ~~~sum uint16(sum) member this.UpdateChecksum() = m_checksum <- this.GetChecksum() type InformationMessage (t : byte) = inherit IcmpMessage(t) let mutable m_identifier = 0us let mutable m_sequenceNumber = 0us member this.Identifier = m_identifier member this.SequenceNumber = m_sequenceNumber override this.Bytes with get() = Array.append (base.Bytes) [| byte(m_identifier) byte(m_identifier >>> 8) byte(m_sequenceNumber) byte(m_sequenceNumber >>> 8) |] type EchoMessage() = inherit InformationMessage( 8uy ) let mutable m_data = Array.create 32 32uy do base.UpdateChecksum() member this.Data with get() = m_data and set(d) = m_data <- d this.UpdateChecksum() override this.Bytes with get() = Array.append (base.Bytes) (this.Data) //---- Synchronous Ping let Ping (host : IPAddress, timeout : int ) = let mutable ep = new IPEndPoint( host, 0 ) let socket = new Socket( AddressFamily.InterNetwork, SocketType.Raw, ProtocolType.Icmp ) socket.SetSocketOption( SocketOptionLevel.Socket, SocketOptionName.SendTimeout, timeout ) socket.SetSocketOption( SocketOptionLevel.Socket, SocketOptionName.ReceiveTimeout, timeout ) let packet = EchoMessage() let mutable buffer = packet.Bytes try if socket.SendTo( buffer, ep ) <= 0 then raise (SocketException()) buffer <- Array.create (buffer.Length + 20) 0uy let mutable epr = ep :> EndPoint if socket.ReceiveFrom( buffer, &epr ) <= 0 then raise (SocketException()) finally socket.Close() buffer //---- Entensions to the F# Async class to allow up to 5 paramters (not just 3) type Async with static member FromBeginEnd(arg1,arg2,arg3,arg4,beginAction,endAction,?cancelAction): Async<'T> = Async.FromBeginEnd((fun (iar,state) -> beginAction(arg1,arg2,arg3,arg4,iar,state)), endAction, ?cancelAction=cancelAction) static member FromBeginEnd(arg1,arg2,arg3,arg4,arg5,beginAction,endAction,?cancelAction): Async<'T> = Async.FromBeginEnd((fun (iar,state) -> beginAction(arg1,arg2,arg3,arg4,arg5,iar,state)), endAction, ?cancelAction=cancelAction) //---- Extensions to the Socket class to provide async SendTo and ReceiveFrom type System.Net.Sockets.Socket with member this.AsyncSendTo( buffer, offset, size, socketFlags, remoteEP ) = Async.FromBeginEnd( buffer, offset, size, socketFlags, remoteEP, this.BeginSendTo, this.EndSendTo ) member this.AsyncReceiveFrom( buffer, offset, size, socketFlags, remoteEP ) = Async.FromBeginEnd( buffer, offset, size, socketFlags, remoteEP, this.BeginReceiveFrom, (fun asyncResult -> this.EndReceiveFrom(asyncResult, remoteEP) ) ) //---- Asynchronous Ping let PingAsync (host : IPAddress, timeout : int ) = async { let ep = IPEndPoint( host, 0 ) use socket = new Socket( AddressFamily.InterNetwork, SocketType.Raw, ProtocolType.Icmp ) socket.SetSocketOption( SocketOptionLevel.Socket, SocketOptionName.SendTimeout, timeout ) socket.SetSocketOption( SocketOptionLevel.Socket, SocketOptionName.ReceiveTimeout, timeout ) let packet = EchoMessage() let outbuffer = packet.Bytes try let! result = socket.AsyncSendTo( outbuffer, 0, outbuffer.Length, SocketFlags.None, ep ) if result <= 0 then raise (SocketException()) let epr = ref (ep :> EndPoint) let inbuffer = Array.create (outbuffer.Length + 256) 0uy let! result = socket.AsyncReceiveFrom( inbuffer, 0, inbuffer.Length, SocketFlags.None, epr ) if result <= 0 then raise (SocketException()) return inbuffer finally socket.Close() }

    Read the article

  • Overloading operator>> to a char buffer in C++ - can I tell the stream length?

    - by exscape
    I'm on a custom C++ crash course. I've known the basics for many years, but I'm currently trying to refresh my memory and learn more. To that end, as my second task (after writing a stack class based on linked lists), I'm writing my own string class. It's gone pretty smoothly until now; I want to overload operator that I can do stuff like cin my_string;. The problem is that I don't know how to read the istream properly (or perhaps the problem is that I don't know streams...). I tried a while (!stream.eof()) loop that .read()s 128 bytes at a time, but as one might expect, it stops only on EOF. I want it to read to a newline, like you get with cin to a std::string. My string class has an alloc(size_t new_size) function that (re)allocates memory, and an append(const char *) function that does that part, but I obviously need to know the amount of memory to allocate before I can write to the buffer. Any advice on how to implement this? I tried getting the istream length with seekg() and tellg(), to no avail (it returns -1), and as I said looping until EOF (doesn't stop reading at a newline) reading one chunk at a time.

    Read the article

  • No Buffer Space available(maximum connection reached?) Form Postgres EDB Driver

    - by Listening.Platform
    We are facing an exception while connecting to database through our java application. The stack trace is as follows com.edb.util.PSQLException: The connection attempt failed. at com.edb.core.v3.ConnectionFactoryImpl.openConnectionImpl(ConnectionFactoryImpl.java:189) at com.edb.core.ConnectionFactory.openConnection(ConnectionFactory.java:64) at com.edb.jdbc2.AbstractJdbc2Connection.<init>(AbstractJdbc2Connection.java:161) at com.edb.jdbc3.AbstractJdbc3Connection.<init>(AbstractJdbc3Connection.java:30) at com.edb.jdbc3.Jdbc3Connection.<init>(Jdbc3Connection.java:24) at com.edb.Driver.makeConnection(Driver.java:391) at com.edb.Driver.connect(Driver.java:266) at java.sql.DriverManager.getConnection(Unknown Source) at java.sql.DriverManager.getConnection(Unknown Source) ... 12 more Caused by: java.net.SocketException: No buffer space available (maximum connections reached?): connect at java.net.PlainSocketImpl.socketConnect(Native Method) at java.net.PlainSocketImpl.doConnect(Unknown Source) at java.net.PlainSocketImpl.connectToAddress(Unknown Source) at java.net.PlainSocketImpl.connect(Unknown Source) at java.net.SocksSocketImpl.connect(Unknown Source) at java.net.Socket.connect(Unknown Source) at java.net.Socket.connect(Unknown Source) at java.net.Socket.<init>(Unknown Source) at java.net.Socket.<init>(Unknown Source) at com.edb.core.PGStream.<init>(PGStream.java:70) at com.edb.core.v3.ConnectionFactoryImpl.openConnectionImpl(ConnectionFactoryImpl.java:115) ... 20 more When the error occured we were not able to connect to internet and DB and had to reboot the system. But the error occured again after 3 days at same code i.e while connecting to DB. We checked TCP connections using netstat. But there were not many TCP connections i.e it has not reached the max limit. Our application has multiple long running Java processes that pools the DB connections (not more than 60) and keeps it alive for firing the next query (as it has to poll the DB every 2 seconds). Some of the queries in our application are joining large tables (10 million records) to get the related data. We are using following System and applications Windows 2003 server SP2 Java 1.6 Postgres Plus Advanced server 8.4 Database edb-jdbc14.jar driver for connection DB from Java We have used the default configuration of Postgres DB except increasing the connection to 120 from 100. Has anybody encountred the same error with postgres edb driver? Can anybody help us finding the solution?

    Read the article

  • Write to memory buffer instead of file with libjpeg?

    - by Richard Knop
    I have found this function which uses libjpeg to write to a file: int write_jpeg_file( char *filename ) { struct jpeg_compress_struct cinfo; struct jpeg_error_mgr jerr; /* this is a pointer to one row of image data */ JSAMPROW row_pointer[1]; FILE *outfile = fopen( filename, "wb" ); if ( !outfile ) { printf("Error opening output jpeg file %s\n!", filename ); return -1; } cinfo.err = jpeg_std_error( &jerr ); jpeg_create_compress(&cinfo); jpeg_stdio_dest(&cinfo, outfile); /* Setting the parameters of the output file here */ cinfo.image_width = width; cinfo.image_height = height; cinfo.input_components = bytes_per_pixel; cinfo.in_color_space = color_space; /* default compression parameters, we shouldn't be worried about these */ jpeg_set_defaults( &cinfo ); /* Now do the compression .. */ jpeg_start_compress( &cinfo, TRUE ); /* like reading a file, this time write one row at a time */ while( cinfo.next_scanline < cinfo.image_height ) { row_pointer[0] = &raw_image[ cinfo.next_scanline * cinfo.image_width * cinfo.input_components]; jpeg_write_scanlines( &cinfo, row_pointer, 1 ); } /* similar to read file, clean up after we're done compressing */ jpeg_finish_compress( &cinfo ); jpeg_destroy_compress( &cinfo ); fclose( outfile ); /* success code is 1! */ return 1; } I would actually need to write the jpeg compressed image just to memory buffer, without saving it to a file, to save time. Could somebody give me an example how to do it? I have been searching the web for a while but the documentation is very rare if any and examples are also difficult to come by.

    Read the article

< Previous Page | 55 56 57 58 59 60 61 62 63 64 65 66  | Next Page >