Search Results

Search found 21546 results on 862 pages for 'infrastructure as a service'.

Page 59/862 | < Previous Page | 55 56 57 58 59 60 61 62 63 64 65 66  | Next Page >

  • Unable to connect to CopSSH when running Windows service, works when running sshd directly

    - by Joe Enos
    I've been using CopSSH (that uses OpenSSH and Cygwin, so I don't know which of the three is the problem) as my SSH server application at home on Windows 7 Ultimate 32 bit. I have used it for about a year with no real problems, other than it sometimes takes 2 or 3 connection attempts to get through, but it's always worked within a few attempts. A few days ago, it just stopped working. The Windows service is still running, and I've rebooted, restarted the service, etc. with no change. On the client (using Putty on Windows), I get the message "Software caused connection abort". On the server, my event viewer registers the following: fatal: Write failed: Socket operation on non-socket I finally got it working, but only by executing sshd.exe directly from the command line on the server. No special flags or options, just straight execution, and then when I connect remotely, it goes through. I do have firewall and anti-virus software which appears to be configured properly, but the fact that things work when running sshd.exe also indicates that the firewall is fine. I thought the service and executable did exactly the same thing, but apparently there's some difference. Does anyone have any ideas on where I should look for the problem? If I can't find something, I suppose I can write a Windows service or scheduled task that fires off sshd.exe directly and ensures that it stays running, but that's kind of a last resort, since it's just wrapping around something that should already work. I appreciate your help.

    Read the article

  • IIS 6 + ASP.NET web service - DW20 and stackoverflow exception

    - by pcampbell
    Consider an ASP.NET SOAP web service that starts up fine, but craters hard when receiving its first hit. Please note that this is deployment works in the Test environment, but not in the PreProd environment. Both are Windows 2003 SP3 + IIS 6 + ASP.NET 3.5. All up-to-date. The behaviour that we're seeing is: restart the site & app pool the app pool is configured to run under Network Service. browsing to the .asmx and .wsdl responds normally, as expected. send a normal well-formed SOAP request / normal payload to the web service 100% CPU usage after 5 seconds, the page request / site returns "Service Unavailable" no entry is created in the IIS log file (i.e. c:\windows\system32\logfiles\W3C-foo) the app pool ends up being stopped The processes that hit the CPU hard are dw20.exe. I am unsure why Dr Watson is involved here. Event Log shows an ASP.NET Runtime error: Task Manager: Event log text: EventType clr20r3, P1 w3wp.exe, P2 6.0.3790.3959, P3 45d6968e, P4 errormanagement, P5 1.0.0.0, P6 4b86a13f, P7 24, P8 0, P9 system.stackoverflowexception, P10 NIL. Questions Any thoughts on what this system.stackoverflow exception might be? Given that the code is the same between environments, might it be a payload problem? Could it be a configuration issue? You can see the name of my .NET assembly there in the exception message: "ErrorManagement"

    Read the article

  • MySQL Workbench is not finding MySQL service? [closed]

    - by PhADDinTraining
    I set up a local MySQL server, currently with no databases. I'm trying to create a new server instance profile in MySQL Workbench to manage the server, and during the Create New Server Instance Profile wizard, it gets to the Windows Management section and tells me that No MySQL service found. I went into Task Manager and found the process mysqld.exe to be running, under the user name of NETWORK SERVICE. Then I went into the Services tab and found that MySQLServerName (I custom named the Windows service) is also there, and status is running. I ran cports and looked at what ports mysqld.exe is using, and ran a telnet command on that port. It's reporting that the port is being listened in on. I then ran the MySQL Command Line Client to be sure, and after \r it gives me a proper connection ID and a list of databases (NONE at this point). But with all this, I can't make the wizard find a running service. I've Googled this and found no answers, so please, if someone would help shed some light on this issue that'd be great!

    Read the article

  • Corporate Wiki Organization - Technical Documentation

    - by Dave Jarvis
    Corporations have documents describing various aspects of their technical systems, including: Custom Applications Custom Development Frameworks Third Party Applications Accounting Bug Tracking Network Management How To Guides User Manuals Software Tools Web Browsers Development IDEs Graphics GIMP xv Text Editing File Transfer ncFTP WinSCP Hardware Servers Web Database Exchange File Network Devices Printers If you had to use a Wiki to manage the documentation, what other items would you add to the list, and how would you organize it? (For example, would Software Tools make more sense under Third Party Applications?) A few constraints: The structure should not go beyond three levels deep. Avoid the word "and" in favour of two different categories. Keep the structure general: it should appy as broadly as possible. Target audience is primarily technical, but could be visible by anyone.

    Read the article

  • Plesk directory structure problems

    - by johnnietheblack
    I have an entire website with the following directory structure: /example.com /html (public) /css /js index.php /lib session.php other_lib_files.php /views index.php /models /controllers As illustrated, the html is public, and anything above it is private. My site now needs to upgrade servers, and the new server (Linux w/ Plesk) has the following structure (reduced to the problematic parts below): /myplesksite.com /httpdocs /css /js index.php /private /lib /models /views What I would THINK is that I should be able to put my /lib, /views, /models, etc in the directory directly above /httpdocs, the same way I had it in my previous server. Is that possible? Or do I have to put it in private? I would really love not to have to adjust my internal paths throughout the site if not necessary...

    Read the article

  • Small Business HP Virtualisation and iSCSI SAN Options

    - by Robin Day
    We are a small business that hosts our core product on a number of HP servers. Our core production setup is 1x HP DL380, high powered for a SQL Server Database 1x HP DL360, mid powered for our core application server 6x HP DL320, low powered for our front ends We run our training / testing / support systems on a similar setup, the servers are just older and less powerful. Unfortunately this is now causing us issues as the system has grown beyond the capabilities of these older servers. Upgrading these servers would be expensive and we believe that virtualisation is probably the way to go for the future. Locally we run a number of test / dev environments on ESXi using Direct Storoage on a couple of high powered DL360's and these are performing fairly well. We're thinking that instead of replacing all of our test servers that we can implement an iSCSI SAN and one or two high powered hosts. Hopefully looking that when it comes to replace our live servers as well that we can just expand the virual environment to cope. So my question is... Can anyone offer any advice on some suitable options? We have generally always been extremely happy with HP servers, all of our kit is currently HP, therefore our preference would be to stick with HP, however, I'm always happy to hear about other options. I'm hoping that initially a budget of around 15-25k (GBP) would be suitable, this could potentially be increased if I had confidence that the system would pave the way for a cost effective upgrade of our live systems in the future as well. I am new to SAN's and my only real experience is playing with OpenFiler on some old desktops. I think iSCSI should be suitable, but I've not done any research into how SQL server may perform. I've had a browser through HP's sites and see plenty of information about EVA, MSA, LeftHand, etc. However, from looking at all that, I don't see which options would be best and more importantly I don't know exactly what I would need to buy. Any help, links, opinions would be much appreciated. Thanks

    Read the article

  • Creating an office network and monitoring all activity without a proxy

    - by Robert
    We are setting up our office network and would like to track all the websites visited by our employees. However, we would not like to use any proxy based solutions. Our work is highly dependent on applications in which you cannot configure a proxy. Hence, the approach we would like to follow is setting up a router inside a computer (something like this : http://www.techrepublic.com/article/configure-windows-server-2003-to-act-as-a-router/5844624) This will also allow us to attach multiple ethernet cards and have redundancy in internet connectivity with complete abstraction from the user about which connection is being used. But most importantly, since all the traffic will be going through the computer (configured as a router) I assume there will be a way to run packet analysis on all the request / responses being made. For example, list all the FTP servers connected to (port 21), give a graph of all the URLs visited per day by frequency. Is there already a software which does this ? Or is it possible to build something like this ?

    Read the article

  • BT socket Device over Structured Cabling

    - by TheD
    Not sure if this is the right stack* site to post on but I believe cabling is a just subject. Essentially I have a Credit Card machine which is connected to a phone line via standard BT Socket. So basically, the port of the wall has a balun plugged in which takes the RJ45 outlet on the wall to BT, so I can plug the device in. This works fine, however I need the machine to be on the other side of the room so want to route it through my patch panel (strucutered cabling). How can this be done? So Device -- ? -- RJ45 port -- Patch Panel -- ? -- Balun out wall outlet Where ? is to be filled in ! :)

    Read the article

  • SharePoint Server Farm, what to do with an old server?

    - by tekiegreg
    Hi there, so we've procured a monster of a SQL Cluster and 4 screaming fast machines running the apps/WFE to start up our MOSS 2007 Enterprise Server farm, however I've got one server from the old server farm configuration that was just re-imaged and is still running decently, it's a 32 bit machine where the others are 64 bit machines so it really can't serve the same role as a 64 bit machine. I'd like to see if there's a role for it somewhere in the farm, a few thoughts: --Dedicated Search Query Server --Dedicated Excel Services Has anyone out there been in a similar situation? What did they do?

    Read the article

  • Deploying Windows Service through group policy fails with Event ID 102

    - by Sören Kuklau
    I'm trying to deploy a custom Windows Service (written in C#; installed through a VS setup project) using a group policy. To help debug this, I also have two additional MSIs in the same policy. All three packages are deployed as a machine policy, not a user one. On one machine (runs Windows Server 2008; no UAC), all three deploy fine. The service is set to Automatic, as expected. On two machines (run Windows 7; UAC), the two other MSIs deploy fine, but my service fails to install. The event log gives an event ID of 102, which appears to be a permissions problem: The install of application "Package Name" from policy "Policy Name" failed. The error was The installation source for this product is not available. Verify that the source exists and that you can access it. However, all three packages come from the same share linked through UNC, so this is unlikely. My guess is that UAC is the problem; that the service requires additional permissions. Do I need to alter the MSI somehow?

    Read the article

  • Hot swapping for Linux web/database servers

    - by Art
    Is there a way to perform the following under Linux: There are two web servers, main and backup There are two database servers (postgres), main and backup Web Servers are in sync with each other, ie. configuration/content/applications are the same Backup database is continuously synced up with main database. If either of main servers goes down, it's being replaced with backup one on the fly. When main database server goes back up, all the data from backup server is uploaded to it. Essentially, I need the hot swapping working automatically with no or minimal user intervention, if possible. Recovery procedure is preferably automatic but can include some manual steps.

    Read the article

  • How do I register a service with Bonjour?

    - by Roman
    I am trying to start to use Bonjour. Here I found a manual how to register a service with Bonjour. The following is written there: The network services architecture in Bonjour includes an easy-to-use mechanism for publishing, discovering, and using IP-based services. Well let's see how to register a service. In the very beginning it is written: To publish a service, an application or device must register the service with a Multicast DNS responder But how?!?! First of all I do not know what is the Multicast DNS responder. Second, it is not written how do I do it. Where and what should I type? Should I use command line? Should I use some programming languages? What exactly should I type... Is there an easy way to start to use Bonjour? Well, it was emphasized several times how easy it should be to use it. But I cannot start to use it for several day. So, can anybody, pleas, help me with that?

    Read the article

  • Do you really need cable management for a cabinet with just switches and patch panels?

    - by ObligatoryMoniker
    We are about to start wiring out a building expansion and our vendor has laid out the racks in the following configuration: Option 1 1U Fiber patch panel 2U Cable Manager 2U 48 port Patch Panel 2U Cable Manager 2U 48 port Patch Panel 2U Cable Manager 1U 48 port Switch 2U Cable Manager 1U 48 port Switch Total = 15U All the patch panels would be connected to the switches with 1ft+ cables fed through cable management. What I am considering instead is: Option 2 1U Fiber patch panel 1U 24 port Patch Panel 1U 48 port Switch 2U 48 port Patch Panel 1U 48 port Switch 2U 48 port Patch Panel Total = 8U All of the patch panels would be connected to the switches with .5 ft cables directly on their face with the top 24 ports of each switch patched to the patch panel above it and the bottom 24 ports of each switch patched to the patch panel beneath it which would not require any cable management. If I go with option 2 it save all of the space used by cable management and allows us to keep adding on switches and patch panels at the end without having to re-cable all of the patch panels above. Our vendor has indicated that this is not best practice and that .5ft cables will introduce cross talk. I could understand that being the case if we were connecting the .5 ft cable directly into another switch but we are connecting it to a patch panel that likely has another 150 ft cable run from the back of the patch panel out to the port in the building in which case the real resulting cable is 150.5 ft at minimum before even connecting it to a PC. It seems like it makes much more sense to go with option 2. It is easier to expand, saves space, and saves money on cabling and cable management. Does this kind of configuration make sense or is there a legitimate reason to choose Option 1 over Option 2?

    Read the article

  • Tridion 2011 SP1 Core Service - expose to live server within PROD env

    - by Neil
    We have a requirement to allow our users to submit information about their "projects" - a small piece of text and single image they upload. Ultimately we'll have a listing page of user contributed projects that others can comment on and rate. We've decided to user Tridion's UGC for rating & comments site-wide for this first phase which has got me thinking - UGC is tied to Tridion published pages & components, if we want UGC on our user-submitted projects, they'll have to be created within Tridion as components themselves, not be sat in some custom db table? Is this where the Core Service could come in? My understanding is that the CD Web Service is for retrieval, not for interacting with the Content Manager. Is it OK (!) architecturally to expose the Core Service only to our live application servers so our backend .NET code can create "project components" that can be then be published by editors allowing them to be commented on? Everything sounds pretty neat and tidy apart from the "exposing Core Service to live servers" bit. Without this though I'd have to write a custom way to "transfer" it back over to the Content Manager - maybe like Audience Manager Sync works? Anyone done this before?

    Read the article

  • Dynamically loading chef recipies from URLs

    - by andy
    I'm deploying a web app on AWS. I intend to use chef to build AMIs which I'll then put into production. I want to have Chef monitor a URL stored in simpleDB. The URL would point to a tarball in S3. There would be different URLs, one for a config tarball, one for a code tarball. When I update the URL in simpleDB, I want chef to spot this and pull in and apply the configs/deploy the code. Is this possible? Has anything like this been done before or would I need to roll my own code? I think Chef can monitor URLs, but how would be the best way of getting it to load that URL from simpleDB?

    Read the article

  • What happens with the Guest OS's on ESXi in the event of a power failure?

    - by Jeremy Holovacs
    Many small businesses would prefer to let their server drop on power failure than to pay even $100 for a cheap UPS. It's often difficult to convince them of the value of something like that; it's why they like ESXi. It's free, they can save a lot of cash by putting a bunch of linux servers on one machine, and then I get paid. :) If the ESXi server experiences a power outage, it is set to come back on automatically when power is restored. What happens with the guest OS's? Ideally I would like them to all come online again as well, assuming they were on when power was lost, but I see no option for choosing this. I don't want to yank power to the system just to try it out, of course. I'm sure someone knows what happens by default, and perhaps how to make my system to work as I would wish.

    Read the article

  • Plesk directory structure problems

    - by johnnietheblack
    I have an entire website with the following directory structure: /example.com /html (public) /css /js index.php /lib session.php other_lib_files.php /views index.php /models /controllers As illustrated, the html is public, and anything above it is private. My site now needs to upgrade servers, and the new server (Linux w/ Plesk) has the following structure (reduced to the problematic parts below): /myplesksite.com /httpdocs /css /js index.php /private /lib /models /views What I would THINK is that I should be able to put my /lib, /views, /models, etc in the directory directly above /httpdocs, the same way I had it in my previous server. Is that possible? Or do I have to put it in private? I would really love not to have to adjust my internal paths throughout the site if not necessary...

    Read the article

  • Force delivery retry without restarting the SMTP Service on Windows Server 2008 R2

    - by Mathias R. Jessen
    I have a Windows Server 2008 R2 box hosting 3 virtual SMTP servers; vSMTP01, vSMTP02 and vSMTP03. The first two are configured to deliver all messages to dedicated smarthosts, while the last is set to just deliver the messages on its own. All other delivery settings are as default ----(vSMTP01)-----> {SMARTHST01} / ----Inbound mail--->---SMTPSRV01---[----(vSMTP02)-----> {SMARTHST02} \ ----(vSMTP03)-----> { Internet } Now I want to take SMARTHST01 out for maintenance, but I don't want to reject submissions to vSMTP01 while doing so, so I just let it continue running. When SMARTHST01 is no longer responding, vSMTP01 queues the messages and wait for the first retry interval to pass (15 minutes). So far so good. Let's say SMARTHST01 gets online again after 20 minutes. The first interval has passed, and I'll have to wait another 25 minutes for the second retry interval to pass. If I stop and start the SMTP Service (Services.msc - Simple Mail Transfer Protocol service - Stop), the server will retry all deliveries, but that would cause a service interruption for ALL virtual SMTP servers on the machine, which is highly undesirable. How can I manually force vSMTP01 to retry delivery of all queued messages without interrupting the service of vSMTP02 and vSMTP03?

    Read the article

  • GroupWise 6.5 IMAP Service Shuts Down-Needs Constant Restarting

    - by Jeffrey Majette
    I have an issue with my aging (and soon to be replaced) GroupWise 6.5 system. The IMAP service in the GWIA tends to periodically shut down, requiring that I restart the service. When IMAP is down, my end users who use Blackberry BIS cannot send or receive email on their devices. It's a royal pain to have to restart the IMAP service several times a day. The GWIA logs do not seem to indicate a problem. I thought I was on to something yesterday. I discovered that the gwia.cfg file located in SYS:SYSTEM was actually from GW 6.0. The gwia.cfg in DOMAIN\WPGATE\GWIA was titled for GW 6.5 when opening the file for editing. I changed the generic placeholder info in the file to match my environment and restarted the gwia. However, it made no difference in performance. The IMAP service shuts down about 30 minutes after the last restart. I know this version of GW is antiquated. We are in the process of migrating to Google Apps. But, if anyone has an idea that could fix this issue, I and my end user community would be forever grateful!

    Read the article

  • Creating a Logical network diagram

    - by user273284
    Im a student and I have been assigned the task of creating a logical network diagram for the following scenario There are 2 buildings, the first is the head office and the second is the branch. The data centre is in the head office, it contains domain controller, mail server, file server and a web server. it provides wired and wireless access to the staff. the branch building is new and it does not have a network. The two buildings must be connected using a VPN connection. The branch building will not have any servers but just network devices that will provide the connectivity, the users in the branch building will be connected to the head office over the VPN. I had created a diagram based on this scenario, but my teacher rejected it saying that it does not follow Cisco hierarchical Model and the servers were not placed correctly in the diagram. I just wanted some help in this matter so that I Can create my network diagram correctly. If anyone could upload a picture of how the logical diagram should be for this scenario will be helpful, any other resources would also be great.

    Read the article

  • Fed up of Server Admin - Want career change guidance

    - by JB04
    Hi All, I am SA in top level MNC and what I liked turned out to be my most disliked. I feel that I am capable of doing more than what I am doing at present. This 1 hour , 2 hour SLA is not my kind. I wanna get a better life.. The rotational shift is also something I am hating these days. Awkward shifts and too many process to follow. I have 3 years of Experience. I dont wanna waste this 3 yrs of experience I wanna get into OS developer or kind of so that this three years of experience is not wasted !! Please help me out

    Read the article

  • Oracle: 1 Large Server vs. 2 Smaller Servers?

    - by nvahalik
    We are in the planning stages of setting up our production Oracle 10gR2 environment. Our budget gives us the ability to buy 2 processor licenses of Oracle DB Standard Edition. We have minimal experience with Oracle so I'll defer to anyone who has used it. We are trying to decide if we should set up a single dual quad-core box or 2 individual quad-core boxes in a RAC configuration. Our DB right now is about 60 GB, and at our peak, we'll have up to 150 concurrent users. Most of the big stuff is done via batch processing at night. My gut tells me that having 2 boxes in a RAC configuration can't be a bad thing because it provides a true hardware failover solution. DB stored in a shared LUN on a SAN via iSCSI. Plus if we ever need to add capacity, we already have boxes in place that can be upgraded with extra procs (I assume with zero downtime, since it's set up in a RAC config) if we add extra licenses, or RAM. Does RAC have any performance penalties? Will it add extra latency? Is there any true advantage for having dual processor boxes running these systems? If we build out the Oracle boxes with special hardware: hardware iSCSI cards, TOE NICs, will these boxes be solid? We are deploying on 64-bit Windows. So what would you do? One box or two?

    Read the article

  • Nagios: turn off service checks/display on down hosts

    - by Alien Life Form
    I want to to tweak nagios in such a way that all checking stops (with services not displayed, or displayed as unknown) for any down node. Said differently I only want to see one alert for a down host instead of 1 (down) + n (1 for every service). Note that I am interested in service display/status, not only in turning off notifications. Rationale: we use the nagios firefox/chrome plugin to monitor status and nagios' behavior is too noisy giving readings like these (because every node has 20 services): 3 down, 1 unreachable, 4 warnings, 87 critical This means that the 7 critical services on up node (the problem is on the service) are swamped in a slab of red services which are critical only because they sit on a node that's down/unreachable. What I'd rather like to see is: 3 down, 1 unreachable, 80 unknown, 4 warnings, 7 critical Or even 3 down, 1 unreachable, 4 warnings, 7 critical I have looked in service dependencies but I did not fine a way to describe: "make all services on a alive-host dependen on the status of the host check". I found the problem discussed here, where one of the participants thought it was a nagios bug, and here where one of the participants thought it was "as designed". As things are, I am just interested in the effect, much less in the design philosophy. Note that this nagios is checking hundreds of nodes, so the maintainablilty of the solution is also important. TIA and cheers.

    Read the article

  • how to build network across buildings ?

    - by Omie
    Hi ! I need some help in building a network between hundreds of computers spread across multiple buildings of my college. Yes, I'll be doing this as a part of my college project. Please see this image, it will give you enough idea of what I'm trying to achieve. http://i.imgur.com/rOohx.png All the computers in all buildings should be able to connect server. Once network is up, there will be a set of services over intranet and network use will be moderate. well, say there will be an email server and a http server. My point is, I cannot afford much of performance loss. It feels easy to connect computers inside 1 building to each other, however, I'm clueless as to how to connect all of them to server. I mean, just 1 cable won't be enough to connect 1 building to server, right ? How should I go with it ? I am not expecting detailed configuration. Just heads up will do :) Thanks

    Read the article

< Previous Page | 55 56 57 58 59 60 61 62 63 64 65 66  | Next Page >