Search Results

Search found 4620 results on 185 pages for 'serial over lan'.

Page 59/185 | < Previous Page | 55 56 57 58 59 60 61 62 63 64 65 66  | Next Page >

  • multiple mysql_real_query() in while loop

    - by Steve
    It seems that when I have one mysql_real_query() function in a continuous while loop, the query will get executed OK. However, if multiple mysql_real_query() are inside the while loop, one right after the other. Depending on the query, sometimes neither the first query nor second query will execute properly. This seems like a threading issue to me. I'm wondering if the mysql c api has a way of dealing with this? Does anyone know how to deal with this? mysql_free_result() doesn't work since I am not even storing the results. //keep polling as long as stop character '-' is not read while(szRxChar != '-') { // Check if a read is outstanding if (HasOverlappedIoCompleted(&ovRead)) { // Issue a serial port read if (!ReadFile(hSerial,&szRxChar,1, &dwBytesRead,&ovRead)) { DWORD dwErr = GetLastError(); if (dwErr!=ERROR_IO_PENDING) return dwErr; } } // Wait 5 seconds for serial input if (!(HasOverlappedIoCompleted(&ovRead))) { WaitForSingleObject(hReadEvent,RESET_TIME); } // Check if serial input has arrived if (GetOverlappedResult(hSerial,&ovRead, &dwBytesRead,FALSE)) { // Wait for the write GetOverlappedResult(hSerial,&ovWrite, &dwBytesWritten,TRUE); //load tagBuffer with byte stream tagBuffer[i] = szRxChar; i++; tagBuffer[i] = 0; //char arrays are \0 terminated //run query with tagBuffer if( strlen(tagBuffer)==PACKET_LENGTH ) { sprintf(query,"insert into scan (rfidnum) values ('"); strcat(query, tagBuffer); strcat(query, "')"); mysql_real_query(&mysql,query,(unsigned int)strlen(query)); i=0; } mysql_real_query(&mysql,"insert into scan (rfidnum) values ('2nd query')",(unsigned int)strlen("insert into scan (rfid) values ('2nd query')")); mysql_free_result(res); } }

    Read the article

  • Using TPL and PLINQ to raise performance of feed aggregator

    - by DigiMortal
    In this posting I will show you how to use Task Parallel Library (TPL) and PLINQ features to boost performance of simple RSS-feed aggregator. I will use here only very basic .NET classes that almost every developer starts from when learning parallel programming. Of course, we will also measure how every optimization affects performance of feed aggregator. Feed aggregator Our feed aggregator works as follows: Load list of blogs Download RSS-feed Parse feed XML Add new posts to database Our feed aggregator is run by task scheduler after every 15 minutes by example. We will start our journey with serial implementation of feed aggregator. Second step is to use task parallelism and parallelize feeds downloading and parsing. And our last step is to use data parallelism to parallelize database operations. We will use Stopwatch class to measure how much time it takes for aggregator to download and insert all posts from all registered blogs. After every run we empty posts table in database. Serial aggregation Before doing parallel stuff let’s take a look at serial implementation of feed aggregator. All tasks happen one after other. internal class FeedClient {     private readonly INewsService _newsService;     private const int FeedItemContentMaxLength = 255;       public FeedClient()     {          ObjectFactory.Initialize(container =>          {              container.PullConfigurationFromAppConfig = true;          });           _newsService = ObjectFactory.GetInstance<INewsService>();     }       public void Execute()     {         var blogs = _newsService.ListPublishedBlogs();           for (var index = 0; index <blogs.Count; index++)         {              ImportFeed(blogs[index]);         }     }       private void ImportFeed(BlogDto blog)     {         if(blog == null)             return;         if (string.IsNullOrEmpty(blog.RssUrl))             return;           var uri = new Uri(blog.RssUrl);         SyndicationContentFormat feedFormat;           feedFormat = SyndicationDiscoveryUtility.SyndicationContentFormatGet(uri);           if (feedFormat == SyndicationContentFormat.Rss)             ImportRssFeed(blog);         if (feedFormat == SyndicationContentFormat.Atom)             ImportAtomFeed(blog);                 }       private void ImportRssFeed(BlogDto blog)     {         var uri = new Uri(blog.RssUrl);         var feed = RssFeed.Create(uri);           foreach (var item in feed.Channel.Items)         {             SaveRssFeedItem(item, blog.Id, blog.CreatedById);         }     }       private void ImportAtomFeed(BlogDto blog)     {         var uri = new Uri(blog.RssUrl);         var feed = AtomFeed.Create(uri);           foreach (var item in feed.Entries)         {             SaveAtomFeedEntry(item, blog.Id, blog.CreatedById);         }     } } Serial implementation of feed aggregator downloads and inserts all posts with 25.46 seconds. Task parallelism Task parallelism means that separate tasks are run in parallel. You can find out more about task parallelism from MSDN page Task Parallelism (Task Parallel Library) and Wikipedia page Task parallelism. Although finding parts of code that can run safely in parallel without synchronization issues is not easy task we are lucky this time. Feeds import and parsing is perfect candidate for parallel tasks. We can safely parallelize feeds import because importing tasks doesn’t share any resources and therefore they don’t also need any synchronization. After getting the list of blogs we iterate through the collection and start new TPL task for each blog feed aggregation. internal class FeedClient {     private readonly INewsService _newsService;     private const int FeedItemContentMaxLength = 255;       public FeedClient()     {          ObjectFactory.Initialize(container =>          {              container.PullConfigurationFromAppConfig = true;          });           _newsService = ObjectFactory.GetInstance<INewsService>();     }       public void Execute()     {         var blogs = _newsService.ListPublishedBlogs();                var tasks = new Task[blogs.Count];           for (var index = 0; index <blogs.Count; index++)         {             tasks[index] = new Task(ImportFeed, blogs[index]);             tasks[index].Start();         }           Task.WaitAll(tasks);     }       private void ImportFeed(object blogObject)     {         if(blogObject == null)             return;         var blog = (BlogDto)blogObject;         if (string.IsNullOrEmpty(blog.RssUrl))             return;           var uri = new Uri(blog.RssUrl);         SyndicationContentFormat feedFormat;           feedFormat = SyndicationDiscoveryUtility.SyndicationContentFormatGet(uri);           if (feedFormat == SyndicationContentFormat.Rss)             ImportRssFeed(blog);         if (feedFormat == SyndicationContentFormat.Atom)             ImportAtomFeed(blog);                }       private void ImportRssFeed(BlogDto blog)     {          var uri = new Uri(blog.RssUrl);          var feed = RssFeed.Create(uri);           foreach (var item in feed.Channel.Items)          {              SaveRssFeedItem(item, blog.Id, blog.CreatedById);          }     }     private void ImportAtomFeed(BlogDto blog)     {         var uri = new Uri(blog.RssUrl);         var feed = AtomFeed.Create(uri);           foreach (var item in feed.Entries)         {             SaveAtomFeedEntry(item, blog.Id, blog.CreatedById);         }     } } You should notice first signs of the power of TPL. We made only minor changes to our code to parallelize blog feeds aggregating. On my machine this modification gives some performance boost – time is now 17.57 seconds. Data parallelism There is one more way how to parallelize activities. Previous section introduced task or operation based parallelism, this section introduces data based parallelism. By MSDN page Data Parallelism (Task Parallel Library) data parallelism refers to scenario in which the same operation is performed concurrently on elements in a source collection or array. In our code we have independent collections we can process in parallel – imported feed entries. As checking for feed entry existence and inserting it if it is missing from database doesn’t affect other entries the imported feed entries collection is ideal candidate for parallelization. internal class FeedClient {     private readonly INewsService _newsService;     private const int FeedItemContentMaxLength = 255;       public FeedClient()     {          ObjectFactory.Initialize(container =>          {              container.PullConfigurationFromAppConfig = true;          });           _newsService = ObjectFactory.GetInstance<INewsService>();     }       public void Execute()     {         var blogs = _newsService.ListPublishedBlogs();                var tasks = new Task[blogs.Count];           for (var index = 0; index <blogs.Count; index++)         {             tasks[index] = new Task(ImportFeed, blogs[index]);             tasks[index].Start();         }           Task.WaitAll(tasks);     }       private void ImportFeed(object blogObject)     {         if(blogObject == null)             return;         var blog = (BlogDto)blogObject;         if (string.IsNullOrEmpty(blog.RssUrl))             return;           var uri = new Uri(blog.RssUrl);         SyndicationContentFormat feedFormat;           feedFormat = SyndicationDiscoveryUtility.SyndicationContentFormatGet(uri);           if (feedFormat == SyndicationContentFormat.Rss)             ImportRssFeed(blog);         if (feedFormat == SyndicationContentFormat.Atom)             ImportAtomFeed(blog);                }       private void ImportRssFeed(BlogDto blog)     {         var uri = new Uri(blog.RssUrl);         var feed = RssFeed.Create(uri);           feed.Channel.Items.AsParallel().ForAll(a =>         {             SaveRssFeedItem(a, blog.Id, blog.CreatedById);         });      }        private void ImportAtomFeed(BlogDto blog)      {         var uri = new Uri(blog.RssUrl);         var feed = AtomFeed.Create(uri);           feed.Entries.AsParallel().ForAll(a =>         {              SaveAtomFeedEntry(a, blog.Id, blog.CreatedById);         });      } } We did small change again and as the result we parallelized checking and saving of feed items. This change was data centric as we applied same operation to all elements in collection. On my machine I got better performance again. Time is now 11.22 seconds. Results Let’s visualize our measurement results (numbers are given in seconds). As we can see then with task parallelism feed aggregation takes about 25% less time than in original case. When adding data parallelism to task parallelism our aggregation takes about 2.3 times less time than in original case. More about TPL and PLINQ Adding parallelism to your application can be very challenging task. You have to carefully find out parts of your code where you can safely go to parallel processing and even then you have to measure the effects of parallel processing to find out if parallel code performs better. If you are not careful then troubles you will face later are worse than ones you have seen before (imagine error that occurs by average only once per 10000 code runs). Parallel programming is something that is hard to ignore. Effective programs are able to use multiple cores of processors. Using TPL you can also set degree of parallelism so your application doesn’t use all computing cores and leaves one or more of them free for host system and other processes. And there are many more things in TPL that make it easier for you to start and go on with parallel programming. In next major version all .NET languages will have built-in support for parallel programming. There will be also new language constructs that support parallel programming. Currently you can download Visual Studio Async to get some idea about what is coming. Conclusion Parallel programming is very challenging but good tools offered by Visual Studio and .NET Framework make it way easier for us. In this posting we started with feed aggregator that imports feed items on serial mode. With two steps we parallelized feed importing and entries inserting gaining 2.3 times raise in performance. Although this number is specific to my test environment it shows clearly that parallel programming may raise the performance of your application significantly.

    Read the article

  • Configuring subversion for visual studio

    - by Fiza
    I have Visual studio 2008 running on windows-7(x86). I have installed subversion (server+client), tortoise svn and ankhsvn on my system. I could add my solution to subversion's repository using the url: File://c:/svn_repository/ But when I try "svn://localhost" I do not see any repository on my system. My friend who is on the same LAN cannot see my repository. What repository URL should I use for others in LAN to be able to see my repository?

    Read the article

  • Multi-site WCF Service

    - by vault
    I have implemented a WCF service that will be used at Site A with 5 computers in the LAN accessing the service. What I would like to do is have an elevated user/administrator be able to use one of the 5 machines and query an identical service at Site B (also with 5 computers) that they will need to connect to by bypassing the LAN firewall.Accessing data from Site A to Site B (and vica-versa) need only be read-only Is there a standardised way to acheive this using WCF?

    Read the article

  • How to make the firewall popup a warning to my http server?

    - by user497032
    I integrated a small http server in my software distribution, so when my customer installs my software, a http server is also installed on his computer, he can visit the http server from his LAN (local network). The problem is that my customer has to manually add my software into the firewall's trusted applications list, I want the firewall to AUTOMATICALLY popup warning to let my customer choose yes/no to add my software into trusted applications list when my customer visit the small http server from LAN at first time. Any suggestions?

    Read the article

  • Routing a PPTP client and VMware Server instance running on the same box

    - by servermanfail
    I have a Windows 2003 SBS box. It has 2 physical NIC's: WAN and LAN. The WAN is a public IP. The LAN is a simple 192.168.2.x subnet with Microsoft DHCP Server. Microsoft Routing and Remote Access Service is used to provide NAT to LAN. The box also runs VMware Server with a virtual machine running Windows XP. I want people to be able to VPN into the box, and connect to these virtual machines on the MSRDP port. I can VPN (PPTP) into the 2003 SBS box fine, as well as ping other machines on the LAN. I can ping the VM from a physical workstation on the LAN and vice-versa. I can ping the VPN client from the a physical workstation on the LAN and vice-versa. I can ping the VPN client from the Server console and vice-versa. I can ping the VM client from the Server console and vice-versa. But I cannot ping the VPN client from the VM and vice-versa. I was hoping to set up 2 or 3 Windows XP virtual machines on our only server, so that a couple of people can remote in to work without having to leave a physical machine on in the office. You could this attempted set up a "poor mans terminal server". On the 2003 SBS Server:- C:\Documents and Settings\Administrator>route print IPv4 Route Table =========================================================================== Interface List 0x1 ........................... MS TCP Loopback interface 0x2 ...00 50 56 c0 00 08 ...... VMware Virtual Ethernet Adapter for VMnet8 0x3 ...00 50 56 c0 00 01 ...... VMware Virtual Ethernet Adapter for VMnet1 0x10004 ...00 53 45 00 00 00 ...... WAN (PPP/SLIP) Interface 0x10005 ...00 11 43 d4 69 13 ...... Broadcom NetXtreme Gigabit Ethernet 0x10006 ...00 11 43 d4 69 14 ...... Broadcom NetXtreme Gigabit Ethernet #2 =========================================================================== =========================================================================== Active Routes: Network Destination Netmask Gateway Interface Metric 0.0.0.0 0.0.0.0 81.123.144.22 81.123.144.21 1 81.123.144.20 255.255.255.252 81.123.144.21 81.123.144.21 1 81.123.144.21 255.255.255.255 127.0.0.1 127.0.0.1 1 81.255.255.255 255.255.255.255 81.123.144.21 81.123.144.21 1 86.135.78.235 255.255.255.255 81.123.144.22 81.123.144.21 1 109.152.62.236 255.255.255.255 81.123.144.22 81.123.144.21 1 127.0.0.0 255.0.0.0 127.0.0.1 127.0.0.1 1 192.168.2.0 255.255.255.0 192.168.2.3 192.168.2.3 1 192.168.2.3 255.255.255.255 127.0.0.1 127.0.0.1 1 192.168.2.26 255.255.255.255 192.168.2.32 192.168.2.32 1 192.168.2.28 255.255.255.255 192.168.2.32 192.168.2.32 1 192.168.2.32 255.255.255.255 127.0.0.1 127.0.0.1 50 192.168.2.50 255.255.255.255 127.0.0.1 127.0.0.1 1 192.168.2.255 255.255.255.255 192.168.2.3 192.168.2.3 1 192.168.10.0 255.255.255.0 192.168.10.1 192.168.10.1 20 192.168.10.1 255.255.255.255 127.0.0.1 127.0.0.1 20 192.168.10.255 255.255.255.255 192.168.10.1 192.168.10.1 20 192.168.96.0 255.255.255.0 192.168.96.1 192.168.96.1 20 192.168.96.1 255.255.255.255 127.0.0.1 127.0.0.1 20 192.168.96.255 255.255.255.255 192.168.96.1 192.168.96.1 20 224.0.0.0 240.0.0.0 81.123.144.21 81.123.144.21 1 224.0.0.0 240.0.0.0 192.168.2.3 192.168.2.3 1 224.0.0.0 240.0.0.0 192.168.10.1 192.168.10.1 20 224.0.0.0 240.0.0.0 192.168.96.1 192.168.96.1 20 255.255.255.255 255.255.255.255 81.123.144.21 81.123.144.21 1 255.255.255.255 255.255.255.255 192.168.2.3 192.168.2.3 1 255.255.255.255 255.255.255.255 192.168.10.1 192.168.10.1 1 255.255.255.255 255.255.255.255 192.168.96.1 192.168.96.1 1 Default Gateway: 81.123.144.22 =========================================================================== Persistent Routes: None C:\Documents and Settings\Administrator>ipconfig /all Windows IP Configuration Host Name . . . . . . . . . . . . : 2003server Primary Dns Suffix . . . . . . . : mycompany.local Node Type . . . . . . . . . . . . : Unknown IP Routing Enabled. . . . . . . . : Yes WINS Proxy Enabled. . . . . . . . : Yes DNS Suffix Search List. . . . . . : mycompany.local gateway.2wire.net Ethernet adapter VMware Network Adapter VMnet8: Connection-specific DNS Suffix . : Description . . . . . . . . . . . : VMware Virtual Ethernet Adapter for VMnet 8 Physical Address. . . . . . . . . : 00-50-56-C0-00-08 DHCP Enabled. . . . . . . . . . . : No IP Address. . . . . . . . . . . . : 192.168.10.1 Subnet Mask . . . . . . . . . . . : 255.255.255.0 Default Gateway . . . . . . . . . : Ethernet adapter VMware Network Adapter VMnet1: Connection-specific DNS Suffix . : Description . . . . . . . . . . . : VMware Virtual Ethernet Adapter for VMnet 1 Physical Address. . . . . . . . . : 00-50-56-C0-00-01 DHCP Enabled. . . . . . . . . . . : No IP Address. . . . . . . . . . . . : 192.168.96.1 Subnet Mask . . . . . . . . . . . : 255.255.255.0 Default Gateway . . . . . . . . . : PPP adapter RAS Server (Dial In) Interface: Connection-specific DNS Suffix . : Description . . . . . . . . . . . : WAN (PPP/SLIP) Interface Physical Address. . . . . . . . . : 00-53-45-00-00-00 DHCP Enabled. . . . . . . . . . . : No IP Address. . . . . . . . . . . . : 192.168.2.32 Subnet Mask . . . . . . . . . . . : 255.255.255.255 Default Gateway . . . . . . . . . : NetBIOS over Tcpip. . . . . . . . : Disabled Ethernet adapter LAN: Connection-specific DNS Suffix . : Description . . . . . . . . . . . : Broadcom NetXtreme Gigabit Ethernet Physical Address. . . . . . . . . : 00-11-43-D4-69-13 DHCP Enabled. . . . . . . . . . . : No IP Address. . . . . . . . . . . . : 192.168.2.50 Subnet Mask . . . . . . . . . . . : 255.255.255.0 IP Address. . . . . . . . . . . . : 192.168.2.3 Subnet Mask . . . . . . . . . . . : 255.255.255.0 Default Gateway . . . . . . . . . : DNS Servers . . . . . . . . . . . : 192.168.2.3 Primary WINS Server . . . . . . . : 192.168.2.3 Ethernet adapter WAN: Connection-specific DNS Suffix . : gateway.2wire.net Description . . . . . . . . . . . : Broadcom NetXtreme Gigabit Ethernet #2 Physical Address. . . . . . . . . : 00-11-43-D4-69-14 DHCP Enabled. . . . . . . . . . . : Yes Autoconfiguration Enabled . . . . : Yes IP Address. . . . . . . . . . . . : 81.123.144.21 Subnet Mask . . . . . . . . . . . : 255.255.255.252 Default Gateway . . . . . . . . . : 81.123.144.22 DHCP Server . . . . . . . . . . . : 10.0.0.1 DNS Servers . . . . . . . . . . . : 10.0.0.1 Primary WINS Server . . . . . . . : 192.168.2.3 NetBIOS over Tcpip. . . . . . . . : Disabled Lease Obtained. . . . . . . . . . : 25 February 2011 22:56:59 Lease Expires . . . . . . . . . . : 25 February 2011 23:06:59 C:\Documents and Settings\Administrator>ping 192.168.2.11 Pinging 192.168.2.11 with 32 bytes of data: Reply from 192.168.2.11: bytes=32 time<1ms TTL=128 Reply from 192.168.2.11: bytes=32 time<1ms TTL=128 Reply from 192.168.2.11: bytes=32 time<1ms TTL=128 Reply from 192.168.2.11: bytes=32 time<1ms TTL=128

    Read the article

  • How to bridge Debian guest VM to VPN via Cisco AnyConnect Client running on Windows Vista host

    - by bgoodr
    I am running Cisco Anyconnect VPN Client version 2.5.3054 on a laptop running Windows Vista Home Premium (version 6.0.6002) Service Pack 2. I am running the VMware Player version 4.0.2 build-591240. The host operating system running under VMware Player is Debian 6.0.2.1 i386. The laptop is connected to a wireless connection, and I can browse the web from Windows Vista using Firefox just fine. I am able to boot into the Debian VM and open up a browser and access websites on the WAN from within the VM just fine. I can ping real Linux hosts on my LAN via: ping <lan_system>.local where <lan_system> is the hostname returned from uname -a on that system on my LAN. From a DOS CMD shell, I am able to ping hosts that exist on the remote network served by the Cisco AnyConnect Client's VPN network (and without the .local suffix applied as above): ping <remote_system> However, from within the Debian VM, I expect to be able to also ping those same remote hosts (<remote_system>) that are tunnelled over the VPN set up by Cisco AnyConnect Client. Let's say that I can ping a <remote_system> called flubber from a DOS CMD prompt just fine. When I execute Linux ping command from inside the Debian VM via: ping flubber It returns immediately with this output: ping: unknown host flubber For reference since I suspect it will be useful, here is the output of the route print command from the DOS CMD prompt: route print =========================================================================== Interface List 30 ...00 05 9a 3c 7a 00 ...... Cisco AnyConnect VPN Virtual Miniport Adapter for Windows 11 ...00 1b 9e c4 de e5 ...... Atheros AR5007EG Wireless Network Adapter 26 ...00 50 56 c0 00 01 ...... VMware Virtual Ethernet Adapter for VMnet1 28 ...00 50 56 c0 00 08 ...... VMware Virtual Ethernet Adapter for VMnet8 1 ........................... Software Loopback Interface 1 12 ...02 00 54 55 4e 01 ...... Teredo Tunneling Pseudo-Interface 13 ...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter #3 32 ...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter #4 27 ...00 00 00 00 00 00 00 e0 isatap.{E5292CF6-4FBB-4320-806D-A6B366769255} 17 ...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter #2 20 ...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter #8 22 ...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter #10 24 ...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter #11 25 ...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter #12 29 ...00 00 00 00 00 00 00 e0 isatap.{C3852986-5053-4E2E-BE60-52EA2FCF5899} 41 ...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter #14 =========================================================================== At the top window border of the VM, clicking on Virtual Machine, then clicking on Virtual Machine Settings, then clicking on Network Adapter, I have these two options checked: [X] Bridged: Connected directly to the physical Network [X] Replicate physical network connection state [ ] NAT: used to share the hosts's IP address [ ] Host-only: A private network shared with the host [ ] LAN segment: [ ] <LAN Segments...> <Advanced> I've toyed with the other options such as NAT and Host-only but that had no effect. Is there some way to allow the VM to access those <remote_system>'s?

    Read the article

  • Cisco ASA 5505 site to site IPSEC VPN won't route from multiple LANs

    - by franklundy
    Hi I've set up a standard site to site VPN between 2 ASA 5505s (using the wizard in ASDM) and have the VPN working fine for traffic between Site A and Site B on the directly connected LANs. But this VPN is actually to be used for data originating on LAN subnets that are one hop away from the directly connected LANs. So actually there is another router connected to each ASA (LAN side) that then route to two completely different LAN ranges, where the clients and servers reside. At the moment, any traffic that gets to the ASA that has not originated from the directly connected LAN gets sent straight to the default gateway, and not through the VPN. I've tried adding the additional subnets to the "Protected Networks" on the VPN, but that has no effect. I have also tried adding a static route to each ASA trying to point the traffic to the other side, but again this hasn't worked. Here is the config for one of the sites. This works for traffic to/from the 192.168.144.x subnets perfectly. What I need is to be able to route traffic from 10.1.0.0/24 to 10.2.0.0/24 for example. ASA Version 8.0(3) ! hostname Site1 enable password ** encrypted names name 192.168.144.4 Site2 ! interface Vlan1 nameif inside security-level 100 ip address 192.168.144.2 255.255.255.252 ! interface Vlan2 nameif outside security-level 0 ip address 10.78.254.70 255.255.255.252 (this is a private WAN circuit) ! interface Ethernet0/0 switchport access vlan 2 ! interface Ethernet0/1 ! interface Ethernet0/2 ! interface Ethernet0/3 ! interface Ethernet0/4 ! interface Ethernet0/5 ! interface Ethernet0/6 ! interface Ethernet0/7 ! passwd ** encrypted ftp mode passive access-list inside_access_in extended permit ip any any access-list outside_access_in extended permit icmp any any echo-reply access-list outside_1_cryptomap extended permit ip 192.168.144.0 255.255.255.252 Site2 255.255.255.252 access-list inside_nat0_outbound extended permit ip 192.168.144.0 255.255.255.252 Site2 255.255.255.252 pager lines 24 logging enable logging asdm informational mtu inside 1500 mtu outside 1500 icmp unreachable rate-limit 1 burst-size 1 asdm image disk0:/asdm-603.bin no asdm history enable arp timeout 14400 global (outside) 1 interface nat (inside) 0 access-list inside_nat0_outbound nat (inside) 1 0.0.0.0 0.0.0.0 access-group inside_access_in in interface inside access-group outside_access_in in interface outside route outside 0.0.0.0 0.0.0.0 10.78.254.69 1 timeout xlate 3:00:00 timeout conn 1:00:00 half-closed 0:10:00 udp 0:02:00 icmp 0:00:02 timeout sunrpc 0:10:00 h323 0:05:00 h225 1:00:00 mgcp 0:05:00 mgcp-pat 0:05:00 timeout sip 0:30:00 sip_media 0:02:00 sip-invite 0:03:00 sip-disconnect 0:02:00 timeout uauth 0:05:00 absolute dynamic-access-policy-record DfltAccessPolicy aaa authentication ssh console LOCAL http server enable http 0.0.0.0 0.0.0.0 outside http 192.168.1.0 255.255.255.0 inside no snmp-server location no snmp-server contact snmp-server enable traps snmp authentication linkup linkdown coldstart crypto ipsec transform-set ESP-3DES-SHA esp-3des esp-sha-hmac crypto map outside_map 1 match address outside_1_cryptomap crypto map outside_map 1 set pfs crypto map outside_map 1 set peer 10.78.254.66 crypto map outside_map 1 set transform-set ESP-3DES-SHA crypto map outside_map interface outside crypto isakmp enable outside crypto isakmp policy 10 authentication pre-share encryption 3des hash sha group 2 lifetime 86400 no crypto isakmp nat-traversal telnet timeout 5 ssh 0.0.0.0 0.0.0.0 outside ssh timeout 5 console timeout 0 management-access inside threat-detection basic-threat threat-detection statistics port threat-detection statistics protocol threat-detection statistics access-list group-policy DfltGrpPolicy attributes vpn-idle-timeout none username enadmin password * encrypted privilege 15 tunnel-group 10.78.254.66 type ipsec-l2l tunnel-group 10.78.254.66 ipsec-attributes pre-shared-key * ! ! prompt hostname context

    Read the article

  • OpenVPN - client-to-client traffic working in one direction but not the other

    - by user42055
    I have the following VPN configuration: +------------+ +------------+ +------------+ | outpost |----------------| kino |----------------| guchuko | +------------+ +------------+ +------------+ OS: FreeBSD 6.2 OS: Gentoo 2.6.32 OS: Gentoo 2.6.33.3 Keyname: client3 Keyname: server Keyname: client1 eth0: 10.0.1.254 eth0: 203.x.x.x eth0: 192.168.0.6 tun0: 192.168.150.18 tun0: 192.168.150.1 tun0: 192.168.150.10 P-t-P: 192.166.150.17 P-t-P: 192.168.150.2 P-t-P: 192.168.150.9 Kino is the server and has client-to-client enabled. All three machines have ip forwarding enabled, by this on the gentoo boxes: net.ipv4.conf.all.forwarding = 1 And this on the FreeBSD box: net.inet.ip.forwarding: 1 In the server's "ccd" directory is the following files: client1: iroute 192.168.0.0 255.255.255.0 client3: iroute 10.0.1.0 255.255.255.0 The server config has these routes configured: push "route 192.168.0.0 255.255.255.0" push "route 10.0.1.0 255.255.255.0" route 192.168.0.0 255.255.255.0 route 10.0.1.0 255.255.255.0 Kino's routing table looks like this: 192.168.150.0 192.168.150.2 255.255.255.0 UG 0 0 0 tun0 10.0.1.0 192.168.150.2 255.255.255.0 UG 0 0 0 tun0 192.168.0.0 192.168.150.2 255.255.255.0 UG 0 0 0 tun0 192.168.150.2 0.0.0.0 255.255.255.255 UH 0 0 0 tun0 Outpost's like this: 192.168.150 192.168.150.17 UGS 0 17 tun0 192.168.0 192.168.150.17 UGS 0 2 tun0 192.168.150.17 192.168.150.18 UH 3 0 tun0 And Guchuko's like this: 192.168.150.0 192.168.150.9 255.255.255.0 UG 0 0 0 tun0 10.0.1.0 192.168.150.9 255.255.255.0 UG 0 0 0 tun0 192.168.150.9 0.0.0.0 255.255.255.255 UH 0 0 0 tun0 Now, the tests. Pings from Guchuko to Outpost's LAN IP work OK, as does the reverse - pings from Outpost to Guchuko's LAN IP. However... Pings from Outpost, to a machine on Guchuko's LAN work fine: .(( root@outpost )). (( 06:39 PM )) :: ~ :: # ping 192.168.0.3 PING 192.168.0.3 (192.168.0.3): 56 data bytes 64 bytes from 192.168.0.3: icmp_seq=0 ttl=63 time=462.641 ms 64 bytes from 192.168.0.3: icmp_seq=1 ttl=63 time=557.909 ms But a ping from Guchuko, to a machine on Outpost's LAN does not: .(( root@guchuko )). (( 06:43 PM )) :: ~ :: # ping 10.0.1.253 PING 10.0.1.253 (10.0.1.253) 56(84) bytes of data. --- 10.0.1.253 ping statistics --- 3 packets transmitted, 0 received, 100% packet loss, time 2000ms Guchuko's tcpdump of tun0 shows: 18:46:27.716931 IP 192.168.150.10 > 10.0.1.253: ICMP echo request, id 63009, seq 1, length 64 18:46:28.716715 IP 192.168.150.10 > 10.0.1.253: ICMP echo request, id 63009, seq 2, length 64 18:46:29.716714 IP 192.168.150.10 > 10.0.1.253: ICMP echo request, id 63009, seq 3, length 64 Outpost's tcpdump on tun0 shows: 18:44:00.333341 IP 192.168.150.10 > 10.0.1.253: ICMP echo request, id 63009, seq 3, length 64 18:44:01.334073 IP 192.168.150.10 > 10.0.1.253: ICMP echo request, id 63009, seq 4, length 64 18:44:02.331849 IP 192.168.150.10 > 10.0.1.253: ICMP echo request, id 63009, seq 5, length 64 So Outpost is receiving the ICMP request destined for the machine on it's subnet, but appears not be forwarding it. Outpost has gateway_enable="YES" in its rc.conf which correctly sets net.inet.ip.forwarding to 1 as mentioned earlier. As far as I know, that's all that's required to make a FreeBSD box forward packets between interfaces. Is there something else I could be forgetting ?

    Read the article

  • How do I connect my Windows XP laptop to the internet?

    - by rubysiddhi
    Hello fellow super users, The Past I have a Acer Travelmate 2300 laptop running Windows XP. 6 months ago I moved into a new apartment and got a new internet connection set up. After getting an internet connection installed in my apartment I reinstalled Windows XP and at the same time wiped my drive clean losing all the original Acer software and drivers. Once XP was reinstalled I had to find all the drivers again to get the Travelmate laptop connected to the internet. So, using my Vista laptop which was connected fine, I went to the Acer Travelmate Series drivers download page to download the necessary drivers. I transferred them to my Acer XP machine and installed them the best I could (there were no easy instructions so I just had to find all the executables and run them). I eventually got connected to the internet but not exactly in the way I had hoped for. The Present To be connected to the internet I need to have an Ethernet cord connecting my computer (via the Ethernet port) to my router. This is a problem since it defeats the purpose of having a Wireless LAN card in my Acer laptop. One of the programs I downloaded from the Acer Travelmate Series page was the Acer Wireless LAN Configuration Utility. This program allows me to see the current network I am connected to and all the available networks I could potentially connect to. It reminds me of XP's Wireless Network Connection window/utility where you can see all available wireless networks, refresh the network list and connect to one of the networks. I should mention that my ISP set up a security enabled wireless network with WPA. This network requires a network key if you want to connect to it. I guess my Vista computer has the network key entered into it already. The problem is that I do not know what the network key is. Now obviously you would say just contact my ISP to get the key. And I will but there is just one extra weird issue. I am able to connect to another unsecured wireless network in the Wireless Network Connection window/utility. I can be on it as long as my Ethernet cable is plugged in. So this is not really wireless is it? And this indicates that even if I do get that network key password from my ISP, I will only solve one of the two problems I have. I will only solve being able to get online as long as I am connected to my router via the Ethernet cable. The Main Questions So how do I enable my acer IPN2220 Wireless LAN Card so that I can use my Acer laptop from anywhere with in my apartment? Or should I first get the network key from my ISP to access my security enabled wireless network? And then deal with getting the acer IPN2220 Wireless LAN Card working? Hard & Learned VS Easy & Stupid Of course contacting the ISP would be easier. Have em just come in here and do there thing. The problem with that is that they do not speak English (yeah, im in Poland) and it'd be a hell of a time trying to understand what they are doing (uncomfortable looking over their shoulder). Also, I want to learn how to do this task myself so that I can fix the problem if it ever happens again. You know, be more self sufficient. I look forward to helpful replies. Thanks, Xaviour

    Read the article

  • Problem installing Cardbus/PCMCIA drivers (USB 2.0 2-port)

    - by Carl
    I obtained the drivers from the manufacturer for my HT-Link NEC USB 2.0 2-port Cardbus card. When I plugged in the card before I got the drivers, 3 new entries showed up in the Device Manager - two "NEC PCI to USB Open Host Controller" and one "Standard Enhanced PCI to USB Host controller." With the card plugged in, I uninstalled those two drivers. I then removed the card. I copied the new drivers to c:\windows\system32\drivers and the .inf file to c:\windows\inf. I also copied the drivers & inf to a new directory called c:\windows\drivers\ousb2. I reinserted the card. Windows automatically installed the same drivers as before. I selected 'update driver' on the "NEC PCI to USB..." entry and didn't see any other options. I then selected 'have disk' and pointed to c:\windows\drivers\ousb2 and got a message "The specified location does not contain information about your hardware." I then selected 'update driver' on the "Standard Enhanced PCI to USB...," and manually selected "USB 2.0 Enhanced Host Controller" (OWC 4/15/2003 2.1.3.1). Windows then automatically found a USB root hub, and I manually selected "USB 2.0 Root Hub Device" (OWC 4/15/2003 2.1.3.1). Now there are two sections in the Device Manager titled "Universal Serial Bus controllers." I plugged in my external USB hard disk adapter, and "USB Mass Storage Device" was added to the first set. Here's how it looks (w/drivers from the properties): [Universal Serial Bus controllers] Intel(R) 82801DB/DBM USB 2.0 Enhanced Host Controller - 24CD (6/1/2002 5.1.2600.0) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C2 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C4 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C7 (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) USB Mass Storage Device USB Root Hub (7/1/2001 5.1.2600.5512) (5 more USB Root Hubs - same driver) [Universal Serial Bus controllers] USB 2.0 Enhanced Host Controller (OWC 4/15/2003 2.1.3.1) USB 2.0 Root Hub Device (OWC 4/15/2003 2.1.3.1) When I unplug the card the two "NEC PCI to USB..." entries in the first set disappear, and the whole second set disappears. (I unplugged the hard disk adapter first...) The hard disk adapter still doesn't work in that Cardbus card with the new drivers. I don't think the above looks right - a second set of USB controllers listed in the Device Manager, and the NEC entries still in the first set, and the the USB mass storage device still in the first set. Any help appreciated. (Windows XP PRO SP3 w/all current updates.)

    Read the article

  • Basic networking problem with Ubuntu 9.04 on Acer Extensa 5635Z laptop

    - by sapporo
    I just installed Ubuntu 9.04 on a brand new Acer Extensa 5635Z laptop, but ethernet networking does't work (wireless doesn't work either, but I'd be happy with ethernet for now). eth0 isn't listed in /etc/network/interfaces: $ cat /etc/network/interfaces auto lo iface lo inet loopback lshw does show the nic, but I can't make much sense out of the information: $ sudo lshw -class network -sanitize *-network DISABLED description: Wireless interface product: AR928X Wireless Network Adapter (PCI-Express) vendor: Atheros Communications Inc. physical id: 0 bus info: pci@0000:07:00.0 logical name: wmaster0 version: 01 serial: [REMOVED] width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix bus_master cap_list logical ethernet physical wireless configuration: broadcast=yes driver=ath9k latency=0 module=ath9k multicast=yes wireless=IEEE 802.11bgn *-network UNCLAIMED description: Ethernet controller product: Attansic Technology Corp. vendor: Attansic Technology Corp. physical id: 0 bus info: pci@0000:09:00.0 version: c0 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress vpd cap_list configuration: latency=0 *-network DISABLED description: Ethernet interface physical id: 1 logical name: pan0 serial: [REMOVED] capabilities: ethernet physical configuration: broadcast=yes driver=bridge driverversion=2.3 firmware=N/A link=yes multicast=yes Thanks for your help!

    Read the article

  • Bladecenter-E Power Module fault

    - by Lihnjo
    We have problem on IBM Bladecenter-E Critical Events Power module 2 is off. DC fault. Power module 4 is off. DC fault. Warnings and System Events Insufficient chassis power to support redundancy What is the best solution for this problem? Thanks AMM Service Data Help SPAPP Capture Available 10/13/2010 17:03:47 1090347 bytes Time: 11/19/2012 11:02:31 UUID: 42E1 5D2F D7BF 41A6 A4A2 48D1 3FB7 0540 MAC Address xx:xx:xx:xx:xx:xx MM Information Name: nnnnn Contact: aaa, bbb, ccc, England Location: [email protected] IP address: 111.222.333.444 Date Time Information GMT offset: +1:00 - Central Europe Time (Western Europe, Algeria, Nigeria, Angola) Adjust for DST: Yes NTP: Enabled NTP Hostname/IP: 111.222.333.444 System Health: Critical System Status Summary One or more monitored parameters are abnormal. Critical Events Power module 2 is off. DC fault. Power module 4 is off. DC fault. Warnings and System Events Insufficient chassis power to support redundancy CHASSIS (BladeCenter-E) in CHASSIS slot: 01 TopoPath is "CHASSIS[1]". Description : BladeCenter-E Width : 1 Sub Type : BladeCenter (BC) Power Mode : 220 v KVM Owner : CHASSIS[1]/BLADE[9] MT Owner : CHASSIS[1]/MGMT_MOD[1] Component Type : CHASSIS Inventory: VPD ID: 336 (decimal) POS ID EXT: 0 (decimal) POS ID: 8 (decimal) Machine Type/Model: 86773RG Machine Serial Number: 99ZL816 Part Number: 39R8561 FRU Number: 39R8563 FRU Serial Number: YK109174W1HV Manufacturer ID: IBM Hardware Revision: 3 (decimal) Manufacture Date: 18 (wk), 07 (yr) UUID: 42E1 5D2F D7BF 41A6 A4A2 48D1 3FB7 0540 (hex) Type Code: 97 (decimal) Sub-type Code: 0 (decimal) IANA Num: 336 (decimal) Product ID: 8 (decimal) Manufacturer Sub ID: FOXC Enviroment data: -------------- Type: : POWER_USAGE Unit: : WATTS Reading: : 0xa Sensor Label: : Midplane Sensor ID: : 0x0 MGMT MOD (Advanced Management Module) in MGMT_MOD slot: 01 TopoPath is "CHASSIS[1]/MGMT_MOD[1]". Description : Advanced Management Module Name : kant Width : 1 Component Role : Primary Component Type : MGMT MOD Insert Time : 28050132 Inventory: VPD ID: 288 (decimal) POS ID EXT: 0 (decimal) POS ID: 4 (decimal) Part Number: 39Y9659 FRU Number: 39Y9661 FRU Serial Number: YK11836CE2RC Manufacturer ID: IBM Hardware Revision: 4 (decimal) Manufacture Date: 50 (wk), 06 (yr) UUID: 1D95 9937 8CA5 11DB 9499 0014 5EDF 1C98 (hex) Type Code: 81 (decimal) Sub-type Code: 1 (decimal) IANA Num: 20301 (decimal) Product ID: 65 (decimal) Manufacturer Sub ID: ASUS Firmware data: Type : AMM firmware Build ID : BPET50P File Name : CNETCMUS.PKT Release Date : 03/26/2010 Release Level : 50 Revision - Major: 80 Port info: ======================================================== Topology Path ID : 1 Label : External Phy Orientation : EXTERNAL Port Number : 1 Type : MGT Physical Meidum : Copper Number of Link Intferfaces : 1 ------------------------------------ Link Ifc ID Number : 1 Link Ifc Transport Protocol : ENET Link Ifc Addr Type : MAC Link Ifc Burned-in Addr : xx:xx:xx:xx:xx:xx Link Ifc Admin Addr : 00:00:00:00:00:00 Link Ifc Addr in use : xx:xx:xx:xx:xx:xx ---------------------------------------------------------- Configuration behaviors: Save Only Enviroment data: -------------- Type: : TEMPERATURE Unit: : DEGREES_C Reading: : 38.00 Sensor Label: : MM Ambient Sensor ID: : 0x0 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +4.81 Sensor Label: : +5V Sensor ID: : 0x1b -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +3.26 Sensor Label: : +3.3V Sensor ID: : 0x19 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +11.97 Sensor Label: : +12V Sensor ID: : 0x16 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : -4.88 Sensor Label: : -5V Sensor ID: : 0x1e -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +2.47 Sensor Label: : +2.5V Sensor ID: : 0x18 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +1.76 Sensor Label: : +1.8V Sensor ID: : 0x15 -------------- Type: : POWER_USAGE Unit: : WATTS Reading: : 0x19 Sensor Label: : kant Sensor ID: : 0x0

    Read the article

  • BIND - zone not loaded du to errors

    - by Johan Barelds
    After upgrading from Ubuntu 8.04 to 10.04 my DNS isn't working properly anymore. I keep getting this error when I run named-checkzone example.com /var/cache/bind/example.com.zone.db zone example.com/IN: NS 'mx002a.example.com' has no address records (A or AAAA) zone example.com/IN: not loaded due to errors. in /var/cached/bind/example.com.db $TTL 3D @ IN SOA mx002a.example.com. chantra.example.com. ( 200608081 ; serial, todays date + todays serial # 8H ; refresh, seconds 2H ; retry, seconds 4W ; expire, seconds 1D ) ; minimum, seconds ; ; mx002a.example.com IN A 192.168.85.19 example.com. IN NS mx002a.example.com. mx001 60 IN A 192.168.85.17 mx001 60 IN A 192.168.85.18

    Read the article

  • keyboard mappings are totally screwed after updating to kde4

    - by zeonglow
    I recently upgraded from KDE 3.5 to KDE 4, and I have been having weird issues with my keyboard. In one of the virtual consoles e.g. when I press ctrl + alt 1 , I can type perfectly, but in KDE, several of the number keys don't work, the left and right arrows don't work either. When I press the right arrow key in xev I get this: KeyRelease event, serial 34, synthetic NO, window 0x3600001, root 0x6f, subw 0x0, time 903459, (111,55), root:(115,836), state 0x10, keycode 114 (keysym 0x1008ff11, XF86AudioLowerVolume), same_screen YES, XLookupString gives 0 bytes: XFilterEvent returns: False When I press the '3' key it toggles my Bookmarks toolbar in Firefox, in xev I get this: KeyPress event, serial 34, synthetic NO, window 0x3600001, root 0x6f, subw 0x0, time 999968, (94,115), root:(98,896), state 0x10, keycode 12 (keysym 0x1008ff30, XF86Favorites), same_screen YES, XLookupString gives 0 bytes: XmbLookupString gives 0 bytes: XFilterEvent returns: False KeyRelease event, serial 34, synthetic NO, window 0x3600001, root 0x6f, subw 0x0, time 1000032, (94,115), root:(98,896), state 0x10, keycode 12 (keysym 0x1008ff30, XF86Favorites), same_screen YES, XLookupString gives 0 bytes: XFilterEvent returns: False As this is deeper down, changing the type of keyboard in the KDE meun's has no effect. I'm slowly beginning to wade through the mountains of documentation about the X keyboard model, but there has to be a better way. Does anyone no what it is? Edit: 1234567890 ! after deleting the entire .kde folder. but only until I change the Keyboard settings from the "system settings" applet, then its hosed full time. Regardless of what I set the settings too. (restore to default settings doesn't) 2nd Edit: I'm using Gentoo AMD64, I was upgrading from KDE 3.5 KDE 4.2. I think I had manual settings before, although I didn't change anything. I was originally running KDE without HAL until that stop working a year or so ago. The only customisation I made was to set the multimedia keys to control Amarok. 3rd Edit $ grep xkb /var/log/Xorg.0.log (**) Option "xkb_rules" "evdev" (**) Option "xkb_model" "evdev" (**) Option "xkb_layout" "us" (**) Option "xkb_rules" "evdev" (**) Option "xkb_model" "evdev" (**) Option "xkb_layout" "us" Xorg.0.log has this to say: (WW) AllowEmptyInput is on, devices using drivers 'kbd', 'mouse' or 'vmmouse' will be disabled. (WW) Disabling Mouse1 (WW) Disabling Keyboard1 My Xorg.conf has this in it. Identifier "Keyboard1" Driver "kbd" Option "AutoRepeat" "500 30" # Specify which keyboard LEDs can be user-controlled (eg, with xset(1)) Option "XkbRules" "xorg" Option "XkbModel" "pc105" Option "XkbLayout" "gb"

    Read the article

  • Device Manager - does USB listing look right?

    - by Carl
    I obtained the drivers from the manufacturer for my HT-Link NEC USB 2.0 2-port Cardbus card. When I plugged in the card before I got the drivers, 3 new entries showed up in the Device Manager - two "NEC PCI to USB Open Host Controller" and one "Standard Enhanced PCI to USB Host controller." With the card plugged in, I uninstalled those two drivers. I then removed the card. I copied the new drivers to c:\windows\system32\drivers and the .inf file to c:\windows\inf. I also copied the drivers & inf to a new directory called c:\windows\drivers\ousb2. I reinserted the card. Windows automatically installed the same drivers as before. I selected 'update driver' on the "NEC PCI to USB..." entry and didn't see any other options. I then selected 'have disk' and pointed to c:\windows\drivers\ousb2 and got a message "The specified location does not contain information about your hardware." I then selected 'update driver' on the "Standard Enhanced PCI to USB...," and manually selected "USB 2.0 Enhanced Host Controller" (OWC 4/15/2003 2.1.3.1). Windows then automatically found a USB root hub, and I manually selected "USB 2.0 Root Hub Device" (OWC 4/15/2003 2.1.3.1). Now there are two sections in the Device Manager titled "Universal Serial Bus controllers." I plugged in my external USB hard disk adapter, and "USB Mass Storage Device" was added to the first set. Here's how it looks (w/drivers from the properties): [Universal Serial Bus controllers] Intel(R) 82801DB/DBM USB 2.0 Enhanced Host Controller - 24CD (6/1/2002 5.1.2600.0) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C2 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C4 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C7 (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) USB Mass Storage Device USB Root Hub (7/1/2001 5.1.2600.5512) (5 more USB Root Hubs - same driver) [Universal Serial Bus controllers] USB 2.0 Enhanced Host Controller (OWC 4/15/2003 2.1.3.1) USB 2.0 Root Hub Device (OWC 4/15/2003 2.1.3.1) When I unplug the card the two "NEC PCI to USB..." entries in the first set disappear, and the whole second set disappears. (I unplugged the hard disk adapter first...) The hard disk adapter still doesn't work in that Cardbus card with the new drivers. I don't think the above looks right - a second set of USB controllers listed in the Device Manager, and the NEC entries still in the first set, and the the USB mass storage device still in the first set. Any help appreciated. (Windows XP PRO SP3 w/all current updates.)

    Read the article

  • Best Processor for MediaSmart Server?

    - by Kent Boogaart
    I'm trying to figure out what the best possible processor is that I can stick in my HP MediaSmart server. I'm clueless when it comes to correlating CPUs to motherboards. I suspect it's the socket type I care about, but I worry that there's more to it. CPU-Z gives me (excerpt): Processors Information ------------------------------------------------------------------------- Processor 1 ID = 0 Number of cores 1 (max 1) Number of threads 1 (max 1) Name AMD Sempron LE-1150 Codename Sparta Specification AMD Sempron(tm) Processor LE-1150 Package Socket AM2 (940) CPUID F.F.1 Extended CPUID F.7F Brand ID 1 Core Stepping DH-G1 Technology 65 nm Core Speed 1000.0 MHz Multiplier x FSB 5.0 x 200.0 MHz HT Link speed 800.0 MHz Stock frequency 2000 MHz Instructions sets MMX (+), 3DNow! (+), SSE, SSE2, SSE3, x86-64 L1 Data cache 64 KBytes, 2-way set associative, 64-byte line size L1 Instruction cache 64 KBytes, 2-way set associative, 64-byte line size L2 cache 256 KBytes, 16-way set associative, 64-byte line size FID/VID Control yes Max FID 10.0x Max VID 1.350 V P-State FID 0x2 - VID 0x12 (5.0x - 1.100 V) P-State FID 0xA - VID 0x0C (9.0x - 1.250 V) P-State FID 0xC - VID 0x0A (10.0x - 1.300 V) K8 Thermal sensor yes K8 Revision ID 6.0 Attached device PCI device at bus 0, device 24, function 0 Attached device PCI device at bus 0, device 24, function 1 Attached device PCI device at bus 0, device 24, function 2 Attached device PCI device at bus 0, device 24, function 3 Chipset ------------------------------------------------------------------------- Northbridge SiS 761GX rev. 02 Southbridge SiS 966 rev. 59 Graphic Interface AGP AGP Revision 3.0 AGP Transfer Rate 8x AGP SBA supported, enabled Memory Type DDR2 Memory Size 2048 MBytes Channels Single Memory Frequency 200.0 MHz (CPU/5) CAS# latency (CL) 5.0 RAS# to CAS# delay (tRCD) 5 RAS# Precharge (tRP) 5 Cycle Time (tRAS) 15 Bank Cycle Time (tRC) 21 Command Rate (CR) 1T DMI ------------------------------------------------------------------------- DMI BIOS vendor Phoenix Technologies, LTD version R03 date 05/08/2008 DMI System Information manufacturer HP product MediaSmart Server version unknown serial CN68330DGH UUID A482007B-B0CC7593-DD11736A-407B7067 DMI Baseboard vendor Wistron model SJD4 revision A.0 serial unknown DMI System Enclosure manufacturer HP chassis type Desktop chassis serial unknown DMI Processor manufacturer AMD model AMD Sempron(tm) Processor LE-1150 clock speed 2000.0 MHz FSB speed 200.0 MHz multiplier 10.0x DMI Memory Controller correction 64-bit ECC Max module size 4096 MBytes DMI Memory Module designation A0 size 2048 MBytes (double bank) DMI Memory Module designation A1 DMI Memory Module designation A2 DMI Memory Module designation A3 DMI Port Connector designation PS/2 Mouse (internal) port type Mouse Port connector PS/2 connector PS/2 DMI Port Connector designation USB0 (external) port type USB DMI Physical Memory Array location Motherboard usage System Memory correction None max capacity 16384 MBytes max# of devices 4 DMI Memory Device designation A0 format DIMM type unknown total width 64 bits data width 64 bits size 2048 MBytes DMI Memory Device designation A1 format DIMM type unknown total width 64 bits data width 64 bits DMI Memory Device designation A2 format DIMM type unknown total width 64 bits data width 64 bits DMI Memory Device designation A3 format DIMM type unknown total width 64 bits data width 64 bits How do I figure out what options I have for an upgrade?

    Read the article

  • Create 8.3 name for an existing directory

    - by Chris Karcher
    I have a machine that initially had 8.3 filename creation disabled. However, this was causing issues with some legacy software, so it was re-enabled. I'm wondering if it's possible to go back and "add" 8.3 filenames to certain existing directories. For example, say I have a directory named "C:\name with spaces" and I get the following output when I run "dir /x": C:\>dir /x Volume in drive C has no label. Volume Serial Number is 6873-65B8 Directory of C:\ 04/09/2010 01:57 PM <DIR> name with spaces ... I'd like to somehow add an 8.3 name for the directory without recreating it, and then get the following: C:\>dir /x Volume in drive C has no label. Volume Serial Number is 6873-65B8 Directory of C:\ 04/09/2010 01:57 PM <DIR> NAMEWI~1 name with spaces ... I tried the 'rename' command but it didn't do the trick.

    Read the article

  • Why can't add a hot spare in freebsd? Can anybody help me fix it?

    - by hamlet
    Why can't add a hot spare? Can anybody help me fix it? mfiutil add e1:s1 mfid0 mfiutil: Drive 1 is not available My mfi status:: mfiutil show config mfi0 Configuration: 1 arrays, 1 volumes, 0 spares array 0 of 2 drives: drive 0 ( 137G) ONLINE <HITACHI HUS153014VLS300 A410 serial=JFWHSB4C> SAS enclosure 1, slot 0 drive 1 ( 137G) ONLINE <HITACHI HUS153014VLS300 A410 serial=JFWJ3AEC> SAS enclosure 1, slot 1 volume mfid0 (136G) RAID-1 64K OPTIMAL spans: array 0 mfiutil show events 1468 (boot + 25s/BATTERY/WARN) - Battery removed 1475 (boot + 52s/DRIVE/WARN) - PD 00(e1/s0) is not a certified drive 1478 (boot + 52s/DRIVE/WARN) - PD 01(e1/s1) is not a certified drive 1480 (boot + 64s/BATTERY/WARN) - BBU disabled; changing WB virtual disks to WT mfiutil show volumes mfi0 Volumes: Id Size Level Stripe State Cache Name mfid0 ( 136G) RAID-1 64K OPTIMAL Disabled

    Read the article

  • Hidden DNS master only sending notify to one slave

    - by Rob
    My hidden DNS master is only sending notifies to one of the name servers for a zone I have 3 named servers ns0,ns1 & ns2 all running bind 9.7.3.dfsg-1ubuntu4.1. When an update is processed the master (ns0) seems to behave normally. ns0 (192.168.2.50) zone domain.org/IN: sending notifies (serial 2012060703) client 192.168.2.52#42892: transfer of 'domain.org/IN': AXFR-style IXFR started: TSIG rndc-key client 192.168.2.52#42892: transfer of 'domain.org/IN': AXFR-style IXFR ended ns2 (192.168.2.52) client 192.168.2.50#3762: received notify for zone 'domain.org': TSIG 'rndc-key' zone domain.org/IN: Transfer started. transfer of 'domain.org/IN' from 192.168.2.50#53: connected using 192.168.2.52#55747 zone domain.org/IN: transferred serial 2012060704: TSIG 'rndc-key' transfer of 'domain.org/IN' from 192.168.2.50#53: Transfer completed: 1 messages, 34 records, 1028 bytes, 0.001 secs (1028000 bytes/sec) Nothing happens on ns1. I've turned up the logging level but there's no information in syslog about the actual name servers bind has sent notifications to so I guess this is something it doesn't log. I've also tried watching tcpdump, it never makes any attempt to notify ns1 only ns2 192.168.2.50.56278 > 192.168.2.52.53: [udp sum ok] 56418 notify [b2&3=0x2400] [1a] [1au] ? SOA? domain.org. domain.org. [0s] SOA ns1.domain.net. dnsmaster.domain.net. ? 2012060801 10800 3600 604800 3600 ar: rndc-key. ANY [0s] TSIG hmac-md5.sig-alg.reg.int. fudge=300 maclen=16 origid=56418 error=0 otherlen=0 (174) the authoritive zone has both ns1 and ns2 records $ORIGIN domain.org. $TTL 3h @ IN SOA ns1.domain.net. dnsmaster.domain.net. ( 2012060801 ; Serial yyyymmddnn 3h ; Refresh After 3 hours 1h ; Retry Retry after 1 hour 1w ; Expire after 1 week 1h ) ; Minimum negative caching of 1 hour @ 3600 IN NS ns1.domain.net. @ 3600 IN NS ns2.domain.net. // Edit I have added also-notify {192.168.2.51;192.168.2.52;}; explicitly to the zone file and it all works fine, both ns1 and ns2 get notify messages and transfers succeed. I was under the impression bind would automatically send notifies to all NS records on a zone, maybe it's bugged?

    Read the article

  • Only One GPU Detected in the Nvidia Quadra NVS 450

    - by Kyle Brandt
    I just built myself an new workstation and now only 2 of 3 monitors are working. I built the nvidia driver by downloading it and installing with ./Nvidia... Before when I ran nvidia-settings I saw two GPUs listed but now I only see one. Xorg Config (Not sure how I ended up with 3 devices in there): # nvidia-settings: X configuration file generated by nvidia-settings # nvidia-settings: version 256.35 (buildmeister@builder101) Wed Jun 16 19:25:39 PDT 2010 Section "ServerLayout" # Removed Option "Xinerama" "1" Identifier "Layout0" Screen 0 "Screen0" 0 0 Screen 1 "Screen1" RightOf "Screen0" InputDevice "Keyboard0" "CoreKeyboard" InputDevice "Mouse0" "CorePointer" Option "Xinerama" "0" EndSection Section "Files" EndSection Section "InputDevice" # generated from default Identifier "Mouse0" Driver "mouse" Option "Protocol" "auto" Option "Device" "/dev/psaux" Option "Emulate3Buttons" "no" Option "ZAxisMapping" "4 5" EndSection Section "InputDevice" # generated from default Identifier "Keyboard0" Driver "kbd" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor0" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor1" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor2" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Device" Identifier "Device0" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:6:0:0" EndSection Section "Device" Identifier "Device1" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:5:0:0" EndSection Section "Device" Identifier "Device2" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:3:0:0" EndSection Section "Screen" # Removed Option "TwinView" "0" # Removed Option "metamodes" "DFP-0: nvidia-auto-select +0+0" # Removed Option "metamodes" "DFP-0: nvidia-auto-select +0+275, DFP-3: nvidia-auto-select +1680+0" Identifier "Screen0" Device "Device0" Monitor "Monitor0" DefaultDepth 24 Option "TwinView" "1" Option "TwinViewXineramaInfoOrder" "DFP-3" Option "metamodes" "DFP-0: nvidia-auto-select +0+0, DFP-3: nvidia-auto-select +1680+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" # Removed Option "metamodes" "DFP-3: nvidia-auto-select +0+0" Identifier "Screen1" Device "Device1" Monitor "Monitor1" DefaultDepth 24 Option "TwinView" "0" Option "metamodes" "nvidia-auto-select +0+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" Identifier "Screen2" Device "Device2" Monitor "Monitor2" DefaultDepth 24 Option "TwinView" "0" Option "metamodes" "nvidia-auto-select +0+0" SubSection "Display" Depth 24 EndSubSection EndSection lscpi: 00:00.0 Host bridge: Intel Corporation 5520/5500/X58 I/O Hub to ESI Port (rev 13) 00:01.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 1 (rev 13) 00:02.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 2 (rev 13) 00:03.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 3 (rev 13) 00:10.0 PIC: Intel Corporation 5520/5500/X58 Physical and Link Layer Registers Port 0 (rev 13) 00:10.1 PIC: Intel Corporation 5520/5500/X58 Routing and Protocol Layer Registers Port 0 (rev 13) 00:11.0 PIC: Intel Corporation 5520/5500 Physical and Link Layer Registers Port 1 (rev 13) 00:11.1 PIC: Intel Corporation 5520/5500 Routing & Protocol Layer Register Port 1 (rev 13) 00:13.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub I/OxAPIC Interrupt Controller (rev 13) 00:14.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub System Management Registers (rev 13) 00:14.1 PIC: Intel Corporation 5520/5500/X58 I/O Hub GPIO and Scratch Pad Registers (rev 13) 00:14.2 PIC: Intel Corporation 5520/5500/X58 I/O Hub Control Status and RAS Registers (rev 13) 00:15.0 PIC: Intel Corporation 5520/5500/X58 Trusted Execution Technology Registers (rev 13) 00:1a.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #4 00:1a.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #5 00:1a.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #6 00:1a.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #2 00:1b.0 Audio device: Intel Corporation 82801JI (ICH10 Family) HD Audio Controller 00:1c.0 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 1 00:1c.1 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Port 2 00:1c.3 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 4 00:1c.4 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 5 00:1d.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #1 00:1d.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #2 00:1d.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #3 00:1d.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #1 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev 90) 00:1f.0 ISA bridge: Intel Corporation 82801JIR (ICH10R) LPC Interface Controller 00:1f.2 IDE interface: Intel Corporation 82801JI (ICH10 Family) 4 port SATA IDE Controller #1 00:1f.3 SMBus: Intel Corporation 82801JI (ICH10 Family) SMBus Controller 00:1f.5 IDE interface: Intel Corporation 82801JI (ICH10 Family) 2 port SATA IDE Controller #2 01:00.0 IDE interface: Device 1b4b:91a3 (rev 11) 02:00.0 USB Controller: NEC Corporation Device 0194 (rev 03) 03:00.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 04:00.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 04:02.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 05:00.0 3D controller: nVidia Corporation G98 [Quadro NVS 450] (rev a1) 06:00.0 VGA compatible controller: nVidia Corporation G98 [Quadro NVS 450] (rev a1) 08:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 08:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 09:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 09:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 0a:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 06) 0b:06.0 FireWire (IEEE 1394): Texas Instruments TSB43AB23 IEEE-1394a-2000 Controller (PHY/Link)

    Read the article

  • dual/multi-boot computers and software licensing

    - by Matt
    Suppose you have a computer with two or more operating systems, and a certain piece of software whose license terms allows it to be installed on one computer, and it does a daily check with a remote server to verify that your serial is only used on the original install computer. You install this software on each of your OSes, but since its a different OS the remote server would have to determine that it is not on the same computer, and so would disable your license. So my question, when a license refers to a single computer, does a situation like this usually count as a single computer, or do the multiple OSes sort of make it multiple computers? How do you think a software vendor (specifically thinking AV companies that do this sort of serial check) would handle this situation?

    Read the article

  • Problem with USB drivers (Windows-XP)

    - by Carl
    I obtained the drivers from the manufacturer for my HT-Link NEC USB 2.0 2-port Cardbus card. When I plugged in the card before I got the drivers, 3 new entries showed up in the Device Manager - two "NEC PCI to USB Open Host Controller" and one "Standard Enhanced PCI to USB Host controller." With the card plugged in, I uninstalled those two drivers. I then removed the card. I copied the new drivers to c:\windows\system32\drivers and the .inf file to c:\windows\inf. I also copied the drivers & inf to a new directory called c:\windows\drivers\ousb2. I reinserted the card. Windows automatically installed the same drivers as before. I selected 'update driver' on the "NEC PCI to USB..." entry and didn't see any other options. I then selected 'have disk' and pointed to c:\windows\drivers\ousb2 and got a message "The specified location does not contain information about your hardware." I then selected 'update driver' on the "Standard Enhanced PCI to USB...," and manually selected "USB 2.0 Enhanced Host Controller" (OWC 4/15/2003 2.1.3.1). Windows then automatically found a USB root hub, and I manually selected "USB 2.0 Root Hub Device" (OWC 4/15/2003 2.1.3.1). Now there are two sections in the Device Manager titled "Universal Serial Bus controllers." I plugged in my external USB hard disk adapter, and "USB Mass Storage Device" was added to the first set. Here's how it looks (w/drivers from the properties): [Universal Serial Bus controllers] Intel(R) 82801DB/DBM USB 2.0 Enhanced Host Controller - 24CD (6/1/2002 5.1.2600.0) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C2 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C4 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C7 (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) USB Mass Storage Device USB Root Hub (7/1/2001 5.1.2600.5512) (5 more USB Root Hubs - same driver) [Universal Serial Bus controllers] USB 2.0 Enhanced Host Controller (OWC 4/15/2003 2.1.3.1) USB 2.0 Root Hub Device (OWC 4/15/2003 2.1.3.1) When I unplug the card the two "NEC PCI to USB..." entries in the first set disappear, and the whole second set disappears. (I unplugged the hard disk adapter first...) The hard disk adapter still doesn't work in that Cardbus card with the new drivers. I don't think the above looks right - a second set of USB controllers listed in the Device Manager, and the NEC entries still in the first set, and the the USB mass storage device still in the first set. Any help appreciated. (Windows XP PRO SP3 w/all current updates.)

    Read the article

< Previous Page | 55 56 57 58 59 60 61 62 63 64 65 66  | Next Page >