  • Latency in TCP/IP-over-Ethernet networks

    - by aix
    What resources (books, Web pages etc) would you recommend that: explain the causes of latency in TCP/IP-over-Ethernet networks; mention tools for looking out for things that cause latency (e.g. certain entries in netstat -s); suggest ways to tweak the Linux TCP stack to reduce TCP latency (Nagle, socket buffers etc). The closest I am aware of is this document, but it's rather brief. Alternatively, you're welcome to answer the above questions directly. edit To be clear, the question isn't just about "abnormal" latency, but about latency in general. Additionally, it is specifically about TCP/IP-over-Ethernet and not about other protocols (even if they have better latency characteristics.)

    Read the article

  • Ethernet switch not working

    - by Froskoy
    I've just tried using two different ethernet switches on my network to replace an 8-port Netgear gigabit ethernet switch, which works fine, but doesn't have enough ports for what I need. Computers are connected to a TP-Link TD-8840T router via a switch. They use DHCP for IP address assignment. One switch is a TigerSwitch 6924M, which I'd expect to be difficult to set up, since it is second hand and has an advanced configuration menu, which I can't access without a serial port. However, the second switch that I tried is a new TP-Link TL-SF024, which doesn't appear to have any configuration options, so that can't be the problem. When I say "not working," I mean that although they display that they are connected to a network, they cannot access the internet. For example commands like "ping -c10 google.co.uk" come up with 100% packet loss. What could be causing the problem and how do I fix it?

    Read the article

  • Desktop PC does not power up on power button

    - by hIpPy
    When I press the power button on my desktop, it does not power up completely. Before I press the power button, I see lights on the motherboard. Everything is normal. On power button press, the fans on the cpu, graphics card and motherboard start to spin a little for a second or two and then they stop. No beeps during this process. It has been doing this for a while now but it used to start up after some trials. Once it starts up, I have NO issues at all like random shutdowns so it is not an issue with OS. I'm just guessing here but it seems as if the PSU (Antec TP2-550ATX) is dying out and does not have enough power now - just a guess. It's an old desktop assembled in 2005 but I have maintained it well. Any ideas? Please help. Thanks. Below is the complete configuration. DFI LAN-Party UT NF4 Ultra-D 6/23 {6.70}, Evercool EC-VC-RE 41/47C, AMD Opteron 170 2.0GHz {1.3.2.16} 1.312V 36/41C, ThermalRight SI-120, Panaflo 120×38mm OCZ Platinum 2×1GB 200MHz 2.66V 3-3-2-7 1T XFX 7800GTX 256MB 475/1250MHz {91.31}, Zalman VF900 Cu led 41/56C WD Caviar 320GB 7200RPM 16MB SATA 3Gb/s Antec TP2-550ATX Antec P180 WinXP sp2 KB896256 Logitech MX310 Razer Mantis Speed BenQ FP91G+ 19" LCD 8ms DVI Creative Audigy2 ZS {4.42} BenQ DW1640 Logitech z-5300e 5.1 280W Legend: Driver versions: {} User settings: [] Voltage: V Wattage: W Temperature: C (Celsius) min/max

    Read the article

  • Desktop PC does not power up on power button

    - by hIpPy
    When I press the power button on my desktop, it does not power up completely. Before I press the power button, I see lights on the motherboard. Everything is normal. On power button press, the fans on the cpu, graphics card and motherboard start to spin a little for a second or two and then they stop. No beeps during this process. It has been doing this for a while now but it used to start up after some trials. Once it starts up, I have NO issues at all like random shutdowns so it is not an issue with OS. Update: I left the desktop off for a few days and it started. I'm just guessing here but it seems as if the PSU (Antec TP2-550ATX) is dying out and does not have enough power now - just a guess. It's an old desktop assembled in 2005 but I have maintained it well. Update: I always keep the desktop running and I never shut it down. During updates or manual restarts, it powers up without issues. I wonder if this sheds lights on the issue. Any idea how I can narrow down the issue? ex: if I can find if the PSU is dying etc. I'd really like to fix the issue. Please help. Thanks. Below is the complete configuration. DFI LAN-Party UT NF4 Ultra-D 6/23 {6.70}, Evercool EC-VC-RE 41/47C, AMD Opteron 170 2.0GHz {1.3.2.16} 1.312V 36/41C, ThermalRight SI-120, Panaflo 120×38mm OCZ Platinum 2×1GB 200MHz 2.66V 3-3-2-7 1T XFX 7800GTX 256MB 475/1250MHz {91.31}, Zalman VF900 Cu led 41/56C WD Caviar 320GB 7200RPM 16MB SATA 3Gb/s Antec TP2-550ATX Antec P180 WinXP sp3 Logitech MX310 Razer Mantis Speed BenQ FP91G+ 19" LCD 8ms DVI Creative Audigy2 ZS {4.42} BenQ DW1640 Logitech z-5300e 5.1 280W Legend: Driver versions: {} User settings: [] Voltage: V Wattage: W Temperature: C (Celsius) min/max

    Read the article

  • What if a computer with Ethernet

    - by George Nixon
    I'm just revising for an exam on Networks and Data Communications, and there's one thing I don't get about CSMA/CD and Ethernet. It's supposed to be fairly stable, for instance if a computer drops out of the network, it's not a problem like it might be in a token ring network (I think). But Ethernet works by all the other computers waiting for the currently transmitting computer to finish what it's doing, and then the others use CMSA/CD to determine who goes next. What if one computer malfunctioned and kept sending a continuous stream of data in an infinite loop? In fact, is there a standard time for pcs to transmit before they yield to others?

    Read the article

  • Good reference for Cisco Resilient Ethernet Protocol

    - by Karthik
    I have been trying to understand Cisco's Resilient Ethernet Protocol, but am unable to find a proper source to read from. I checked the Cisco site and also their White Paper on REP. But none of them helped to understand REP clearly. Googling was also of not much help, as all I got was explanation about configuration instructions and not on the protocol itself. Can you guys point me to a good book or site, which explains Resilient Ethernet Protocol in detail? Thanks in advance.

    Read the article

  • WebCenter Customer Spotlight: Guizhou Power Grid Company

    - by me
    Author: Peter Reiser - Social Business Evangelist, Oracle WebCenter  Solution SummaryGuizhou Power Grid Company is responsible for power grid planning, construction, management, and power distribution in Guizhou Province, serving 39 million people. Giuzhou has 49,823 employees and an annual revenue of over $5 Billion. The business objectives were to consolidate information contained in disparate systems into a single knowledge repository and provide a safe and efficient way for staff and managers to access, query, share, manage, and store business information. Guizhou Power Grid Company saved more than US$693,000 in storage costs, reduced  average search times from 180 seconds to 5 seconds and solved 80% to 90% of technology and maintenance issues by searching the Oracle WebCenter Content management system. Company OverviewA wholly owned subsidiary of China Southern Power Grid Company Limited, Guizhou Power Grid Company is responsible for power grid planning, construction, management, and power distribution in Guizhou Province, serving 39 million people. Giuzhou has 49,823 employees and an annual revenue of over $5 Billion. Business ChallengesThe business objectives were to consolidate information contained in disparate systems, such as the customer relationship management and power grid management systems, into a single knowledge repository and provide a safe and efficient way for staff and managers to access, query, share, manage, and store business information. Solution DeployedGuizhou Power Grid Company  implemented Oracle WebCenter Content to build a content management system that enabled the secure, integrated management and storage of information, such as documents, records, images, Web content, and digital assets. The content management solution was integrated with the power grid, customer service, maintenance, and other business systems, as well as the corporate Web site. Business Results Saved more than US$693,000 in storage costs and shortened the material distribution time by integrating the knowledge management solution with the power grid, customer service, maintenance, and other business systems, as well as the corporate Web site Enabled staff to search 31,650 documents using catalogs, multidimensional attributes, and knowledge maps, reducing average search times from 180 seconds to 5 seconds and saving approximately 1,539 hours in annual search time Gained comprehensive document management, format transformation, security, and auditing capabilities Enabled users to upload new documents and supervisors to check the accuracy of these documents online, resulting in improved information quality control Solved 80% to 90% of technology and maintenance issues by searching the Oracle content management system for information, ensuring IT staff can respond quickly to users’ technical problems Improved security by using role-based access controls to restrict access to confidential documents and information Supported the efficient classification of corporate knowledge by using Oracle’s metadata functions to collect, tag, and archive documents, images, Web content, and digital assets “We chose Oracle WebCenter Content, as it is an outstanding integrated content management platform. It has allowed us to establish a system to access, query, share, manage, and store our corporate assets. This has laid a solid foundation for Guizhou Power Grid Company to improve management practices.” Luo Sixi, Senior Information Consultant, Guizhou Power Grid Company Additional Information Guizhou Power Grid Company Customer Snapshot Oracle WebCenter Content

    Read the article

  • DH61AG's mythical 2 pin 19v power socket and is too low of votage bad?

    - by Nick Orton
    I have an intel dh61ag motherboard. It has an external 19v power adapter. It also has a 1x2 pin 19VDC internal power connector. Now I cannot find a psu or adapter or anything that will plug into this. In an intel forum, one person said that he plugged half of a 2x2 psu connector in and it worked. Since this would deliver 12v into a socket that asks for 19v, I suspect that this is a bad idea. I don't know much about hardware. Can anyone explain to me why this would be a bad idea?

    Read the article

  • Computer sometimes doesn't boot after power failure, what should I replace?

    - by user1416256
    I have a new computer that behaves strange after a power failure. When I switch off the computer it will not boot anymore. Completely unplugging the computer for about an hour cures the issue for the next boot. The internal leds are working I have no idea where to start looking. What, in your opinion could be the cause of this strange behaviour ? My best bet would be to replace the power supply Would that be a good place to start ?

    Read the article

  • Computer making strange sound when turned on, ever since power outage

    - by Dot NET
    Recently we experienced a power outage, and the PC was off. However, once the power came back, I switched on the PC and heard a strange noise - almost as if the hard disk or fans were struggling to work. I can't really describe the sound, but it's a laboured, loud sound almost like a jack-hammer. This has been persisting ever since the power outage, however the noise stops after around 10 minutes or so, and doesn't start again until the computer is turned off and on again. At first I thought it had something to do with the HDD, but all my files are intact, chkdsk did not report any issues and performance is 100% unchanged, even in games (so the gfx card is fine, and so is the HDD most likely). My PC setup basically has around 3 cooling fans, but I'm not sure if it's one of these either as the noise actually stops after 10 minutes or so, and if I leave the PC on for 4 hours (for example) the noise never starts again. It's there solely when turning on the PC. I haven't got a UPS, and it's important to note that the computer was not on when the power went out - it was merely plugged in. I then promptly unplugged the PC once the power was out, and only plugged it in again when the power came back. Could it be the power supply? Unfortunately I can't open my tower as I would void the warranty. Are there any tests which I could carry out without voiding the warranty?

    Read the article

  • New XPC: No video, no ethernet link, but drive spins

    - by Mike Pennington
    I bought a Shuttle XPC SH67H3 with integrated video. I installed: An Intel i5 2450P 16GB DDR3 RAM A SATA hard drive from my old linux server that still is bootable I have both power connectors plugged into the motherboard. I realize that the Intel i5-2450P doesn't have video capabilities; however, the drive spins like it's doing something useful. It seems like I should get an ethernet link light when I fire this up. I plan to run this headless anyway, so it would be really nice if I could figure out how to run this without a video card at all. I know the IP address and login info for the linux install on the disk. I plugged in speakers, but get no bios beeps when I power it up. Shuttle's bios manual has nothing in there that indicates I should have problems in this configuration. My questions: Is there a reason that the missing video card would block usage of the ethernet port? Are there settings on the motherboard / bios I can change to get this working?

    Read the article

  • Hyper-V Virtual Machine Networking issues related to Max Ethernet Frame Size

    - by Goatmale
    I fixed an issue today earlier today but i'm interested in learning WHY it worked. We set up a new Hyper-V virtual machine only to discover that HTTP traffic wasn't working. HTTPS, pings, everything else was working fine. After months of prodding around I took a shot in the dark. On the Hyper-V host server, the physical NIC card had an advanced setting of "Max Ethernet Frame Size" set to 1500. After setting this setting to 1514 the issue was fixed. Alternatively, setting this to 1512 did not solve the issue; 1514 is the magic number. My best guess it that when this setting was set to 1500 it was allowing incoming pings because the data payload was a lot smaller of say, HTTP traffic. As far as HTTPS traffic, I read about something called "Path MTU discovery" which i'm going to assume why is HTTPs traffic was getting through fine, albeit slower. Looking at this post, people agree that 1518 is the max total frame size. Why didn't I need to change this to 1518 instead of 1514 bytes? Why is the default frame size 1500 if that's the max size of the Ethernet payload and not the max size.

    Read the article

  • 802.11g -> wired ethernet bridging not working

    - by Malachi
    Usually people want to go the other direction, but I want to take our relatively fast and stable house 802.11g signal and bridge it to ethernet. I have tried using an Airport Express (the b/g flavor) and my i7 MacBook pro, both to no avail. Word is that the b/g flavor of This flavor of Airport Express maxes at firmware 6.3 which doesn't support this kind of bridging properly. However, I expected my MacBook pro to do the job with its "Internet Sharing" feature. Alas, although my wired PC does sort of see it, it doesn't work out. Strangely, using DHCP the PC receives the same IP address as my MBP uses on the network. Less strangely, but still surprisingly, the wired ethernet port on my mac registers as the IP address of the gateway when queried with IFCONFIG. It sort of makes sense that the mac would "pretend" to be the gateway, but the whole thing just isn't working and seems configured wrong - but all the docs I see say basically "OS X Internet Sharing: click it and go". What do I do? Do i really have to buy more hardware, even though I have plenty of would-be candidates for bridging? Incidentally, the host router originating the 802.11g signal is a belkin 802.11g router, and is documented to support WDS.

    Read the article

  • How to find polarity of a power supply that's lacking the customary markings

    - by Nosredna
    If I have a power supply (not a computer power supply, just a battery-replacing wall wart) and it doesn't have the usual polarity marking, how to I know if the tip is positive or negative? Update: I couldn't find my multimeter. I did find a model number on the power supply and typed it into Google. Some guy selling a bunch of power supplies on eBay had checked it and found that it was tip positive, which is what I needed!

    Read the article

  • Windows 7 Goes to Sleep in conflict with Power Option Setting

    - by Decker
    My Del Dimension E521 running Windows 7 puts itself in sleep mode each night -- despite the fact that I have chosen a power option that specifies NEVER Each morning I find the monitor blank and I have to hit the power button on the PC at which point Windows "resumes". The system event log shows this: Source: Microsoft-Windows-Kernel-Power Date: 3/27/2010 3:21:10 AM Description: The system is entering sleep. Sleep Reason: System Idle My specific power options are: Turn off Display : 20 Minutes Put the computer to sleep : Never Is there some other setting coming into play here?

    Read the article

  • structure of ethernet frame (tcp/udp) [closed]

    - by rtmrtm2
    How is an ethernet-frame structured. is it: |MAC | |_______________| | |IP | | |___________| | |TCP | | |_______| | |HTTP| |__________|____| or the other way around? so in words: is the mac wrapped around the ip wrapped around the tcp wrapped arround the http? can someone post an image of the specific 'wrapping'? thanks in advance. regards, rtmrtm2

    Read the article

  • Latest AutoVue Podcast - Customer Success at Ringhals/Vattenfall

    - by pam.petropoulos(at)oracle.com
    Ringhals, a Swedish nuclear power plant, part of the Vattenfall Group, produces 20% of the country's electricity and is the largest power station in the Nordic region. Ringhals has standardized on AutoVue for most of their engineering and asset document visualization requirements throughout their plant maintenance, design and engineering operations. This audio interview, hosted by Folia Grace, Oracle Vice President of Application Product Marketing, features Harald Carlsson, Documentation Administrator at Ringhals/Vattenfall. Hear Harald describe how they have cut IT maintenance costs, increased productivity, and improved maintenance operations throughout their facility. Click here to listen to the podcast

    Read the article

  • Connecting via Ethernet on second AirPort Extreme

    - by b-b
    Would It be possible to connec my xbox 360 to a second AirPort Extreme, wherein this AirPort Extreme is wirelessly linked to the first? I assume it is and is straight forward, but I thought I'd ask first. Also, would an Ethernet to a second AirPort Extreme be any faster than, say, a dual band wifi connection from a MacBook? Obviously environmental factors play in, but I'm mostly curious about the relative receiving strength of the airport vs laptop.

    Read the article

  • resolv.conf not working properly with Ethernet in Ubuntu

    - by Mark Z.
    I have a Lenovo X200 laptop on which I am running Ubuntu 9.10. Recently, (I assume after some updating, but I really don't know) my ethernet port stopped working under Linux. A more tech/linux-savvy friend of mine was able to temporarily fix the problem by manually editing the resolv.conf file with the DNS servers he found through his connection. However, after rebooting, the problem came back and now I am looking for a more permanent solution.

    Read the article

  • Broadcom 440x Ethernet NIC Drivers and Windows Home Server

    - by scottman666
    I have installed Windows Home Server on an older Dell computer, and it uses a Broadcom 440x Ethernet NIC driver. I have tried all of the drivers listed on their drivers page to no luck. The error message I get when trying to install is: "The parameter is incorrect" I know it is a long shot, but anybody have any suggestions? Thanks!

    Read the article

  • Why ethernet cables must be ended with specific arrangement

    - by adopilot
    I just accepted that ethernet cables CAT 5 and more must be ended with specific arrangement. I learned when I ending my cables to take attention that either end must be in same arrangement(568A or 568B ). Sometime I get stacked with my fellow servant that they claim that Cable should work if just arrangement at both side are same even if it is not in 568A or 568B layouts. My experience said that it is not true, but I am now looking for some technical argument to prove that.

    Read the article

  • Latency in TCP/IP-over-Ethernet networks

    - by aix
    What resources (books, Web pages etc) exist out there that: explain the causes of latency in TCP/IP-over-Ethernet networks; mention tools for looking out for things that cause latency (e.g. certain entries in netstat -s); suggest ways to tweak the Linux TCP stack to reduce TCP latency (Nagle, socket buffers etc). The closest I am aware of is this document, but it's rather brief. Alternatively, you're welcome to answer the above questions directly.

    Read the article

  • Why ethernet calbes must be ended with specific arrangement

    - by adopilot
    I just accepted that ethernet cables CAT 5 and more must be ended with specific arrangement. I learned when I ending my cables to take attention that either end must be in same arrangement(568A or 568B ). Sometime I get stacked with my fellow servant that they claim that Cable should work if just arrangement at both side are same even if it is not in 568A or 568B layouts. My experience said that it is not true, but I am now looking for some technical argument to prove that.

    Read the article