  • Dell External SAS 5/E HBA and Hyper-V

    - by JohnyD
    I have a Dell R710 running Win2008 R2 + Hyper-V with dual SAS 5/E HBA's. I'm building a Linux VM to install Bacula on and I need to connect it to my Dell PowerVault 124T via the SAS HBA. I've been doing some looking online and I have yet to find a straightforward answer on how to connect a SAS HBA to a VM, let alone a Linux VM. The flavor is Ubuntu 32-bit.

    Read the article

  • Is there a Distributed SAN/Storage System out there?

    - by Joel Coel
    Like many other places, we ask our users not to save files to their local machines. Instead, we encourage that they be put on a file server so that others (with appropriate permissions) can use them and that the files are backed up properly. The result of this is that most users have large hard drives that are sitting mainly empty. It's 2010 now. Surely there is a system out there that lets you turn that empty space into a virtual SAN or document library? What I envision is a client program that is pushed out to users' PCs that coordinates with a central server. The server looks to users just like a normal file server, but instead of keeping entire file contents it merely keeps a record of where those files can be found among various user PCs. It then coordinates with the right clients to serve up file requests. The client software would be able to respond to such requests directly, as well as be smart enough to cache recent files locally. For redundancy the server could make sure files are copied to multiple PCs, perhaps allowing you to define groups in different locations so that an instance of the entire repository lives in each group to protect against a disaster in one building taking down everything else. Obviously you wouldn't point your database server here, but for simpler things I see several advantages: Files can often be transferred from a nearer machine. Disk space grows automatically as your company does. Should ultimately be cheaper, as you don't need to keep a separate set of disks I can see a few downsides as well: Occasional degradation of user pc performance, if the machine has to serve or accept a large file transfer during a busy period. Writes have to be propogated around the network several times (though I suspect this isn't really much of a problem, as reading happens in most places more than writing) Still need a way to send a complete copy of the data offsite occasionally, and this would make it very hard to do differentials Think of this like a cloud storage system that lives entirely within your corporate LAN and makes use of your existing user equipment. Our old main file server is due for retirement in about 2 years, and I'm looking into replacing it with a small SAN. I'm thinking something like this would be a better fit. As a school, we have a couple computer labs I can leave running that would be perfect for adding a little extra redundancy to the system. Unfortunately, the closest thing I can find is Dienst, and it's just a paper that dates back to 1994. Am I just using the wrong buzzwords in my searches, or does this really not exist? If not, is there a big downside that I'm missing?

    Read the article

  • Lessons from a SAN Failure

    - by Bill Graziano
    At 1:10AM Sunday morning the main SAN at one of my clients suffered a “partial” failure.  Partial means that the SAN was still online and functioning but the LUNs attached to our two main SQL Servers “failed”.  Failed means that SQL Server wouldn’t start and the MDF and LDF files mostly showed a zero file size.  But they were online and responding and most other LUNs were available.  I’m not sure how SANs know to fail at 1AM on a Saturday night but they seem to.  From a personal standpoint this worked out poorly: I was out with friends and after more than a few drinks.  From a work standpoint this was about the best time to fail you could imagine.  Everything was running well before Monday morning.  But it was a long, long Sunday.  I started tipsy, got tired and ended up hung over later in the day. Note to self: Try not to go out drinking right before the SAN fails. This caught us at an interesting time.  We’re in the process of migrating to an entirely new set of servers so some things were partially moved.  This made it difficult to follow our procedures as cleanly as we’d like.  The benefit was that we had much better documentation of everything on the server.  I would encourage everyone to really think through the process of implementing your DR plan and document as much as possible.  Following a checklist is much easier than trying to remember at night under pressure in a hurry after a few drinks. I had a series of estimates on how long things would take.  They were accurate for any single server failure.  They weren’t accurate for a SAN failure that took two servers down.  This wasn’t bad but we should have communicated better. Don’t forget how many things are outside the database.  Logins, linked servers, DTS packages (yikes!), jobs, service broker, DTC (especially DTC), database triggers and any objects in the master database are all things you need backed up.  We’d done a decent job on this and didn’t find significant problems here.  That said this still took a lot of time.  There were many annoyances as a result of this.  Small settings like a login’s default database had a big impact on whether an application could run.  This is probably the single biggest area of concern when looking to recreate a server.  I’d encourage everyone to go through every single node of SSMS and look for user created objects or settings outside the database. Script out your logins with the proper SID and already encrypted passwords and keep it updated.  This makes life so much easier.  I used an approach based on KB246133 that worked well.  I’ll get my scripts posted over the next few days. The disaster can cause your DR process to fail in unexpected ways.  We have a job that scripts out all logins and role memberships and writes it to a file.  This runs on the DR server and pulls from the production server.  Upon opening the file I found that the contents were a “server not found” error.  Fortunately we had other copies and didn’t need to try and restore the master database.  This now runs on the production server and pushes the script to the DR site.  Soon we’ll get it pushed to our version control software. One of the biggest challenges is keeping your DR resources up to date.  Any server change (new linked server, new SQL Server Agent job, etc.) means that your DR plan (and scripts) is out of date.  It helps to automate the generation of these resources if possible. Take time now to test your database restore process.  We test ours quarterly.  If you have a large database I’d also encourage you to invest in a compressed backup solution.  Restoring backups was the single larger consumer of time during our recovery. And yes, there’s a database mirroring solution planned in our new architecture. I didn’t have much involvement in things outside SQL Server but this caused many, many things to change in our environment.  Many applications today aren’t just executables or web sites.  They are a combination of those plus network infrastructure, reports, network ports, IP addresses, DTS and SSIS packages, batch systems and many other things.  These all needed a little bit of attention to make sure they were functioning properly. Profiler turned out to be a handy tool.  I started a trace for failed logins and kept that running.  That let me fix a number of problems before people were able to report them.  I also ran traces to capture exceptions.  This helped identify problems with linked servers. Overall the thing that gave me the most problem was linked servers.  In order for a linked server to function properly you need to be pointed to the right server, have the proper login information, have the network routes available and have MSDTC configured properly.  We have a lot of linked servers and this created many failure points.  Some of the older linked servers used IP addresses and not DNS names.  This meant we had to go in and touch all those linked servers when the servers moved.

    Read the article

  • UPK Customer Success Story: The City and County of San Francisco

    - by karen.rihs(at)oracle.com
    The value of UPK during an upgrade is a hot topic and was a primary focus during our latest customer roundtable featuring The City and County of San Francisco: Leveraging UPK to Accelerate Your PeopleSoft Upgrade. As the Change Management Analyst for their PeopleSoft 9.0 HCM project (Project eMerge), Jan Crosbie-Taylor provided a unique perspective on how they're utilizing UPK and UPK pre-built content early on to successfully manage change for thousands of city and county employees and retirees as they move to this new release. With the first phase of the project going live next September, it's important to the City and County of San Francisco to 1) ensure that the various constituents are brought along with the project team, and 2) focus on the end user aspects of the implementation, including training. Here are some highlights on how UPK and UPK pre-built content are helping them accomplish this: As a former documentation manager, Jan really appreciates the power of UPK as a single source content creation tool. It saves them time by streamlining the documentation creation process, enabling them to record content once, then repurpose it multiple times. With regard to change management, UPK has enabled them to educate the project team and gain critical buy in and support by familiarizing users with the application early on through User Experience Workshops and by promoting UPK at meetings whenever possible. UPK has helped create awareness for the project, making the project real to users. They are taking advantage of UPK pre-built content to: Educate the project team and subject matter experts on how PeopleSoft 9.0 works as delivered Create a guide/storyboard for their own recording Save time/effort and create consistency by enhancing their recorded content with text and conceptual information from the pre-built content Create PeopleSoft Help for their development databases by publishing and integrating the UPK pre-built content into the application help menu Look ahead to the next release of PeopleTools, comparing the differences to help the team evaluate which version to use with their implemtentation When it comes time for training, they will be utilizing UPK in the classroom, eliminating the time and cost of maintaining training databases. Instructors will be able to carry all training content on a thumb drive, allowing them to easily provide consistent training at their many locations, regardless of the environment. Post go-live, they will deploy the same UPK content to provide just-in-time, in-application support for the entire system via the PeopleSoft Help menu and their PeopleSoft Enterprise Portal. Users will already be comfortable with UPK as a source of help, having been exposed to it during classroom training. They are also using UPK for a non-Oracle application called JobAps, an online job application solution used by many government organizations. Jan found UPK's object recognition to be excellent, yet it's been incredibly easy for her to change text or a field name if needed. Please take time to listen to this recording. The City and County of San Francisco's UPK story is very exciting, and Jan shared so many great examples of how they're taking advantage of UPK and UPK pre-built content early on in their project. We hope others will be able to incorporate these into their projects. Many thanks to Jan for taking the time to share her experiences and creative uses of UPK with us! - Karen Rihs, Oracle UPK Outbound Product Management

    Read the article

  • Slides, Code, and Photos from SPTechCon San Francisco 2011

    - by Brian Jackett
    Note: Updated 2/12/11 with links to both presentation materials.     This past week I presented two sessions at SPTechCon San Francisco 2011.  The first session was “The Expanding Developer Toolbox for SharePoint 2010” which .  Thanks to all of my attendees for this session.  They had so many great questions that we ran out of time before covering all of the planned material.  Especially for them I’ve provided the slides and code samples to walk through them on their own.     The second session was “Real World Deployment of SharePoint 2007 Solutions”.  In talking with attendees before the session many were looking for 2007 content.  At the conference SharePoint 2010 was represented much more heavily than 2007, so I was glad to fill a need in the community. Slides and Code   Click here for “The Expanding Developer Toolbox for SharePoint 2010” materials   Click here for “Real World Deployment of SharePoint 2007 Solutions” materials Photos Pictures on FaceBook   Click here Pictures on Windows Live (higher res)     SPTechCon San Fran Feb 2011 VIEW SLIDE SHOW DOWNLOAD ALL Side Trips     Aside from the conference itself I also got to take a few side trips during the nights.  A special thanks to Dux Raymond Sy (Twitter) for organizing a Mongolian Hot Pot dinner on Monday (see pictures) and Michael Noel (Twitter) for organizing a Korean bbq dinner on Tuesday (again see pictures).  These were both new experiences for me and I thoroughly enjoyed the time with friends and trying something new.  Another thanks to Mark Miller (Twitter) for giving a personal tour around various sites of San Fran to myself and a few others.  It was great hearing the backstory of different neighborhoods and buildings from someone who had lived in the area for years.  Overall a great addition to the conference itself. Conclusion     This is the 3rd SPTechCon I’ve attended and the conference is getting better with each iteration.  The fine folks at BZ Media should be proud of the effort they’ve put in.  The next SPTechCon will be in Boston in June.  As of right now I won’t be attending that one but I highly recommend anyone to go if you have the chance.         -Frog Out

    Read the article

  • PostgreSQL server: 10k RPM SAS or Intel 520 Series SSD drives?

    - by Vlad
    We will be expanding the storage for a PostgreSQL server and one of the things we are considering is using SSDs (Intel 520 Series) instead of rotating discs (10k RPM). Price per GB is comparable and we expect improved performance, however we are concerned about longevity since our database usage pattern is quite write-heavy. We are also concerned about data corruption in case of power failure (due to SSDs write cache not flushing properly). We currently use RAID10 with 4 active HDDs (10k 146GB) and 1 spare configured in the controller. It's a HP DL380 G6 server with P410 Smart Array Controller and BBWC. What makes more sense: upgrading the drives to 300GB 10k RPM or using Intel 520 Series SSDs (240GB)?

    Read the article

  • Cheapest way to connect 20-24 Sata II HDDs in a budget storage server?

    - by Joe Hopfgartner
    I need to assemble a high density storage server for as cheap as possible. It's been a while for me and the last systems I integrated didn't even have Sata yet... During my Research I of course stumbled about Nexsan SATA Beast, the BackBlaze storage Pods as well as some ridiculously overpriced HP Proliant or Dell storage solutions. Finally I choose Norco cases as the way to go. My eye is set on the RPC-4020, which is a 4U 19" Rackmount case with 20 Hot Swap 3.5" SATA/SAS Hdd trays (Backplanes included) and room for two 2.5" OS drives as well as a Slim Line CD-Rom. The backplanes connect with a single SATA port for each drive, so there are 20 internal SATA ports to to be connected. They also have redundant power ports which I think is quite nice. The cheapest price I have found is 290$ + 40$ shipping. In europe the cheapest unfortunately is 370€ (500$) + 40 € shipping... A nice alternative would be the RPC-4224 which has SFF-8087 Mini SAS connectors that bundle 4 SATA trays each. But it doesn't seem to be available in Europe (where i am) anywhere. So here comes my problem: What Mainboard/Controller to choose to connect them for as cheap as possible while still having nice data rates? I have to say that the server is intended as a Storage server with 1gps connectivity and the data transfer will be distributed very evenly across all drives. I also don't require any raid functionality. This is all done at application level, I just need JBOD. So for example if I go for the RPC 4020 Model I need to connect 20 Storage + 1 OS + 1 CDROM Sata ports. I searched a bit and stumbled across this very low priced controller: http://www.intel.com/products/server/raid-controllers/SASWT4I/SASWT4I-overview.htm They sell it for 115 € here and the specs say it can control up to 122 hard discs and has 4 Mini SAS connectors. So I would use 4 Mini SAS 36pin - 4 SATA 7pin cables to connect 4 SATA drives to each port and choose a Mainboard taht has 6 SATA on board (for example this one) and hurray, I can connect my 22 SATA devices for as low as about ~ 220 EUR (cpu, ram, psu, case not counted) Question: WOULD THAT WORK? And if not, why? 2nd Question: If I go for the 4220 or 4224 Model, I have internal Mini SAS connectors. Am I right in assuming that the backplane than acts as a "SAS Expander"? And can I just plug these SAS connectors into any SAS port I can find on my controller / mainboard or are there certain requirements? I know that SATA port multipliers only work with controllers that are ready for that. But isn't this expansion already implemented in the SAS standard? I am sorry that this is a very broad question, but I really spent the last week reading up and it seems to be not so clear! Especially all the controlling hardware specifications! 3rd Question: A lot of hardware specs feature "internal channels" and "internal connectors". The connecors are the physical numbers of places where I can plug a cable in. I got that. But are the "internal channels" always the maximum numbers of physical drives that can be used in the end? Or can I enhance this further by Expanders/Fanouts? 4th and last question: What do you think about the setup so far? Do you know any good alternatives? Maby I am completely going the wrong way and some DAS would be way better? Are there any comparable chassis available in europe? Please feel free to say whatever you think is relevant to the subject!

    Read the article

  • Are there no downsides to NetApp SAN solutions other than price?

    - by flashkube
    We have pretty much decided on a NetApp solution for our first SAN. Given that, I've been tasked with finding as much reason not to go with NetApp as I can. We like to do this A) so we know what we're getting into and B) so we aren't clouded by the inevitable post vendor demo euphoria. I have scoured the internet for cons and can only find one: price. Have you had a nightmare experience with NetApp that you just want to get off your chest? Please, only people with NetApp experience. Thank you!

    Read the article

  • SAN newbie: What kind of fiber cables do I need to connect to the front end ports on my EMC CX300

    - by red888
    I have an old CX300 I'm messing with and I cant determine what kind of HBA\fiber cables I need to connect a server to the front end ports on the DPE2. The hardware reference doesn't give me any details and being new to FC-SAN all of the options are pretty overwhelming. I don't know if the ports are SC or LC or if it requires singlemode or multimode. Googling hasn't turned up anything for me either. All I know is that it supports 2GB Fiber. Here is a pic of one the modules. You can clearly see the front-end ports (FE)

    Read the article

  • HP MSA 1000 SAN: Can I use 1 array/shelf?

    - by CC
    Hi all, I'm planning some expansion on an HP MSA1000 SAN. My boss says that we need to have two separate arrays on the new enclosure, one for Bays 1-7, the other for Bays 8-14. Is there any reason that we need to do this? My plan was to have the entire expansion shelf be 1 array, then create RAID 6 logical drives from that. I don't understand what splitting drives into separate arrays gain us. We don't have dual controllers, so there's no benefit there. Thanks, CC

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Cheapest iSCSI SAN for Windows 2008/SQL Server clustering?

    - by MichaelGG
    Are there any production-quality iSCSI SANs suitable for use with Windows Server 2008/SQL Server for failover clustering? So far, I've only seen Dell's MD3000i, and HP's MSA 2000 (2012i), which both are around $6K with a minimal disk configuration. Buffalo (yea, I know), has a $1000 device with iSCSI support, but they say it will not work for 2008 failover clustering. I'm interested in seeing something suitable for failover in a production environment, but with very low IO requirements. (Clustering, say, a 30GB DB.) As for using software: On Windows, StarWind seems to have a great solution. But it's actually more money than buying a hardware SAN. (As I understand, only the enterprise edition supports having replicas, and that's $3000 a license.) I was thinking I could use Linux, something like DRBD + an iSCSI target would be fine. However, I haven't seen any free or low-cost iSCSI software that supports SCSI-3 persistent reservations, which Windows 2008 needs for failover clustering. I know $6K isn't much at all, just curious to see if there are practical cheaper solutions out there. And finally, yes, the software is expensive, but many small business get MS BizSpark, so the Windows 2008 Enterprise / SQL 2008 licenses are completely free.

    Read the article

  • How to best tune my SAN/Initiators for best performance?

    - by Disco
    Recent owner of a Dell PowerVault MD3600i i'm experiencing some weird results. I have a dedicated 24x 10GbE Switch (PowerConnect 8024), setup to jumbo frames 9K. The MD3600 has 2 RAID controllers, each has 2x 10GbE ethernet nics. There's nothing else on the switch; one VLAN for SAN traffic. Here's my multipath.conf defaults { udev_dir /dev polling_interval 5 selector "round-robin 0" path_grouping_policy multibus getuid_callout "/sbin/scsi_id -g -u -s /block/%n" prio_callout none path_checker readsector0 rr_min_io 100 max_fds 8192 rr_weight priorities failback immediate no_path_retry fail user_friendly_names yes # prio rdac } blacklist { device { vendor "*" product "Universal Xport" } # devnode "^sd[a-z]" } devices { device { vendor "DELL" product "MD36xxi" path_grouping_policy group_by_prio prio rdac # polling_interval 5 path_checker rdac path_selector "round-robin 0" hardware_handler "1 rdac" failback immediate features "2 pg_init_retries 50" no_path_retry 30 rr_min_io 100 prio_callout "/sbin/mpath_prio_rdac /dev/%n" } } And iscsid.conf : node.startup = automatic node.session.timeo.replacement_timeout = 15 node.conn[0].timeo.login_timeout = 15 node.conn[0].timeo.logout_timeout = 15 node.conn[0].timeo.noop_out_interval = 5 node.conn[0].timeo.noop_out_timeout = 10 node.session.iscsi.InitialR2T = No node.session.iscsi.ImmediateData = Yes node.session.iscsi.FirstBurstLength = 262144 node.session.iscsi.MaxBurstLength = 16776192 node.conn[0].iscsi.MaxRecvDataSegmentLength = 262144 After my tests; i can barely come to 200 Mb/s read/write. Should I expect more than that ? Providing it has dual 10 GbE my thoughts where to come around the 400 Mb/s. Any ideas ? Guidelines ? Troubleshooting tips ?

    Read the article

  • Problems with 2 ISCSI connections esxi 3.5

    - by rphilli5
    I am running a dell poweredge 1950 with 4 nic cards. 1 is bonded to SAN #1 on 192.168.90.xx. The second SAN is on a separate network - 192.168.7.xx The network adapter can view the ip range of the san and the NIC can be pinged from 192.168.7.xx range. vswitch1 and vswitch2 are configured identically except for the ip address. The second SAN has been added to the iscsi software adapter but the SAN is never recognized. I can connect to the SAN from other machines on the local network. Is there something else that needs to be configured for the iscsi software adapter to know which vswitch to use?

    Read the article

  • Sep 10 Week - I'll be on the West Coast Speaking in Irvine and San Fran

    - by RickHeiges
    In my role as a Solutions Architect for Scalability Experts, I often get to present to customers about the work that we performed. Unfortunately, this is often on short notice and I can't coordinate a trip to participate in a User Group Meeting. Next week, I was able to coordinate my west coast trip to be able to present. I am heading to Irvine at the MTC on Sepember 11 and San Francisco at the MSFT offices on Sep 13 to speak to customers who want to learn more about SQL Server 2012.To register for...(read more)

    Read the article

  • Data Governance 2010 Conference in San Diego

    - by Tony Ouk
    The Data Governance Annual Conference is one of the world's most authoritative and vendor neutral event on Data Governance and Data Quality.  The conference will focus on the "how-tos" from starting a data governance and stewardship program to attaining data governance maturity with specific topics on MDM.  This year's event will be hosted June 7 through June 10 in San Diego, California. For more information, including registration details, visit the Data Governance 2010 Conference website.

    Read the article

  • First-Global-Teach for the Oracle Imaging and Process Management 11g: Administration: San Francisco

    - by stephen.schleifer
    First-Global-Teach for the Oracle Imaging and Process Management 11g: Administration: San Francisco | June 23-25 This course enables participants to use Oracle Imaging and Process Management (I/PM) 11g to access, track, and annotate documents. In addition, they also get an overview of the product architecture of Oracle I/PM running on Oracle WebLogic Server.The course also delves into administration tasks such as security permissions, configuration such as creating BPEL connections, and procedures for creating applications, searches, and input mappings. Customer and partners can register by looking up the course (#D61575GC10) on http://education.oracle.com

    Read the article

  • MDM 2010 Summit in San Francisco

    - by Tony Ouk
    Since 2006, the MDM Global Summit Series has brought master data expertise to more than 5,000 delegates worldwide. The Series is designed to reinforce the importance of data governance as a key factor to your MDM program's success while providing real-world experience and all-in-one access to solutions providers. Come join us June 2-3, 2010 at the Hyatt Regency in San Francisco.  For more information including registration details, visit the MDM Global Summit Series website.

    Read the article

  • xTuple Announces Sponsorship of DrupalCon San Francisco

    <b>LinuxPR:</b> xTuple, the leader in Mac and <a href="http://www.xtuple.com/">open source enterprise resource planning (ERP) software</a> for small to medium-sized businesses (SMBs), today announced its sponsorship of DrupalCon San Francisco, which will take place April 19-21, 2010, at the Moscone Center.

    Read the article

  • San Francisco DotNetNuke User's Group

    If you are anywhere in the San Francisco Bay or Silicon Valley area this post is for you. Others are welcome, but you might find the drive a little long depending on where you are. On 3/23/2010 we are going to be holding our first DotNetNuke Users Group...(read more)...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • JavaOne San Francisco 2012????

    - by sasa
    2012?11?13???????????????JavaOne San Francisco 2012?????????????Java Embedded???Java????????????????????????????? ????Watch - ???????????????Java~???????Java?????? ASCII.jp - ?????????????HTML5?????????Java???????????????????? ITpro - ???????Java EE 7?????????????????????? nikkei BPnet - ???????Java EE 7?????????????????????? ITmedia ???????? - Java???????? ?????? Computerworld.jp - ???????Java????????????????Java EE 7??????????8???

    Read the article