Search Results

Search found 1650 results on 66 pages for 'sas san'.

Page 12/66 | < Previous Page | 8 9 10 11 12 13 14 15 16 17 18 19  | Next Page >

  • Has anyone used products by StorSimple? [closed]

    - by AlamedaDad
    Their products are storage systems similar to NetApp, but their "hook" is they provide automated tiered storage with the third tier being Cloud providers like Amazon and Azure. They have an interesting story in which they provide primary SAN/iSCSI storage to VMWare and Exchange and at the same time do snaphots to the Cloud. This provides a possible DR option if you have a second system at an alternate location. I was impressed, but I've never heard of them so I'm looking for input and advise on the product. Thanks in advance...

    Read the article

  • What is the best backup solution for VMware Infrastructure system that hosts a wide variety of VMs?

    - by SBWorks
    In a situation where you are running: VMware Infrastructure 4.x with multiple hosts Over 150 VMs with a wide variety of operating systems (Linux in a half dozen distros, Solaris, every MS version, etc.) in multiple languages with almost every mix of installed software (luckily, no Exchange mail servers) Using an EMC fiber channel SAN The VWs that need need to be backed up use about 2 terabytes of data (total) The goal is to keep backups for about 3-months At this rough scale, what backup solutions have worked well for you? And, as an add-on question, did any of them have de-duplication that you thought was effective and useful?

    Read the article

  • Virtual fiber channel HBA in Solaris

    - by Phil
    We are trying to set up some virtual Fibre Channel HBA's in Solaris. This seems to be possible with NPIV. Creating NPIV's in a Solaris global zone works fine, but passing that NPIV to a zone didn't work at all. We tried to pass the NPIV as following: # zonecfg -z zone1 'info' zonename: studentz1 [...] device: match: /devices/pci@0,0/pci8086,25f9@6/pci8086,350c@0,3/pci1077,140@4/fp@1,0:devctl allow-partition not specified allow-raw-io not specified Wat we want to do is, set up an environment for SAN exercises. We don't have a physical host per student, so we try to virtualise that in some way (Solaris zones or VMware). It should be possible to display the WWN of the virtual HBA and mount the storage presented by the disk subsystem. Any ideas to pass the NPIV to a solaris zone or to virtualise this with vmware?

    Read the article

  • Cannot extend existing data disk over 2TB on windows 2008 with dynamic and gpt part

    - by DJYod
    As my D: disk is almost full (2TB) I extended the FC lun to 2.5TB. The new 500Go are seen by windows as "Unalloacted" as expected. I tried to extend the volume but windows says "The is not enough space available on the disk(s) to complete this operation" I read on the web that the disk should be configured as GPT and as a dynamic and it's already a dynamic gpt disk... How can I extend my disk without any data loss? My operating system is Windows 2008 R2 x64 SP1 and the SAN a 3PAR I hope someone can help me :) Thank you very much

    Read the article

  • Multiple iSCSI Targets or 1 that's shared?

    - by Joost Verdaasdonk
    On my network I have several types of files I want to save on a SAN like: SQL db's and logs Exchange data Random files Now I'm wondering if I should create one iSCSI Target with a large volume and initiate that from one of the servers. (and share it so other servers can use it too) Or I should create separate Targets to have each server use its own storage. For the record the storage could be separated because the servers aren't using the shared data. For one reason I was thinking of one storage is ease of backup. (but perhaps performance could be a problem?) What would be an advisable configuration for these type of data?

    Read the article

  • Simple Central Storage for HA mail server

    - by jtnire
    Hi Everyone, I will have 2 Postfix servers. One will be a backup of the other. What is the easiest method to provide central storage to both of these boxes? My infrastructure is very simple: Just a lot of Xen hosts, so there is no SAN or anything. Each Xen host does have RAID1 though. I don't mind mounting NFS shares on each of those mail servers, as long as the NFS server wasn't a single point of failure. Is there such a thing as redundant NFS? Any help would be appreciated Thanks

    Read the article

  • Categorize data without consolidating?

    - by sqlnoob
    I have a table with about 1000 records and 2000 columns. What I want to do is categorize each row such that all records with equal column values for all columns except 'ID' are given a category ID. My final answer would look like: ID A B C ..... Category ID 1 1 0 3 1 2 2 1 3 2 3 1 0 3 1 4 2 1 3 2 5 4 5 6 3 6 4 5 6 3 where all columns (besides ID) are equal for IDs 1,3 so they get the same category ID and so on. I guess my thought was to just write a SQL query that does a group by on every single column besides 'ID' and assign a number to each group and then join back to my original table. My current input is a text file, and I have SAS, MS Access, and Excel to work with. (I could use proc sql from within SAS). Before I go this route and construct the whole query, I was just wondering if there was a better way to do this? It will take some work just to write the query, and I'm not even sure if it is practical to join on 2000 columns (never tried), so I thought I'd ask for ideas before I got too far down the wrong path. EDIT: I just realized my title doesn't really make sense. What I was originally thinking was "Is there a way I can group by and categorize at the same time without actually consolidating into groups?"

    Read the article

  • 150 TB and growing, but how to grow?

    - by seandavi
    My group currently has two largish storage servers, both NAS running debian linux. The first is an all-in-one 24-disk (SATA) server that is several years old. We have two hardware RAIDS set up on it with LVM over those. The second server is 64 disks divided over 4 enclosures, each a hardware RAID 6, connected via external SAS. We use XFS with LVM over that to create 100TB useable storage. All of this works pretty well, but we are outgrowing these systems. Having build two such servers and still growing, we want to build something that allows us more flexibility in terms of future growth, backup options, that behaves better under disk failure (checking the larger filesystem can take a day or more), and can stand up in a heavily concurrent environment (think small computer cluster). We do not have system administration support, so we administer all of this ourselves (we are a genomics lab). So, what we seek is a relatively low-cost, acceptable performance storage solution that will allow future growth and flexible configuration (think ZFS with different pools having different operating characteristics). We are probably outside the realm of a single NAS. We have been thinking about a combination of ZFS (on openindiana, for example) or btrfs per server with glusterfs running on top of that if we do it ourselves. What we are weighing that against is simply biting the bullet and investing in Isilon or 3Par storage solutions. Any suggestions or experiences are appreciated.

    Read the article

  • P2v options within a hyper-v environment.

    - by tony roth
    I have a server that san boots that I want to p2v. I have many options disk2vhd, scvmm etc but I was thinking about cloning the lun (flexclone, netapp) presenting it to my hyper-v r2 server. Within the hv manager do a create new disk then have it copy the cloned lun to a vhd file. Then do the bcdedit\bootsect stuff to it. Should work right? I'm also curious if anybodys booting vhd's that are on bootable luns? I've booted native vhd's just fine was just curious about the running them off a bootable lun. I think that this has quite a few advantages like instant p2v etc.. any thoughts on this? hmm dang as I was typing this I realized that I should not use the hv manager new disk copy routine, I should just disk2vhd the mounted lun. This has advantages in that it should be a lot faster!! discovered that disk2vhd may be flaky, crashed the first time I ran it! thanks

    Read the article

  • Booting VM Directly from iSCSI (or FC) in Hyper-V R2

    - by tony roth
    I have a server that san boots that I want to p2v. I have many options disk2vhd, scvmm etc but I was thinking about cloning the lun (flexclone, netapp) presenting it to my hyper-v r2 server. Within the hv manager do a create new disk then have it copy the cloned lun to a vhd file. Then do the bcdedit\bootsect stuff to it. Should work right? I'm also curious if anybodys booting vhd's that are on bootable luns? I've booted native vhd's just fine was just curious about the running them off a bootable lun. I think that this has quite a few advantages like instant p2v etc.. any thoughts on this? hmm dang as I was typing this I realized that I should not use the hv manager new disk copy routine, I should just disk2vhd the mounted lun. This has advantages in that it should be a lot faster!! discovered that disk2vhd may be flaky, crashed the first time I ran it! thanks

    Read the article

  • Xen guests accessing LUNs

    - by mechcow
    We are using RHEL5.3 with a Clarion SAN attached by FC. Our situation is that we have a number of LUNs presented to Hosts and we want to dynamically present the LUNs to Xen Guests. We are not sure on what the best practice approach is to set this up. The Xen guests will form a cluster together and need the LUNs only for data partitions, i.e. when they are actively running services. So one approach would be to always present all disks to all Xen guests, and then rely up on the cluster software, and mount itself, to not mount the disk twice in two locations. This sounds kinda risky and also is not very secure (one cracked guest can see/destroy all the data). Another approach would be to dynamically add and remove the disks from the Xen guests at the dom0 level (using xm block-attach). This could work but sounds slightly complicated, I'm wondering whether Red Hat Cluster Suite supports this in some way or whether there are scripts to do this. Yet another approach would be to have the LUNs endpointed at the Xen guests themselves - I'm not sure whether this is technically possible since the multipathing has to be done at the Host level.

    Read the article

  • Creating basic, redundant gigE or IB storage network for Xen?

    - by StaringSkyward
    With only a modest budget, I want to move my 4 xen servers over to network storage -either NFS or iSCSI which will be determined based on how well it performs when we test it (we need good throughput and it must continue to work through link and switch failure tests). We may add another couple of xen servers at some point when this is done. I don't know much about the design and operation of storage networks, so would really appreciate some hints from those with experience. The budget is around $3,800 excluding the storage appliance. I am currently thinking these are my options to remain on budget: 1) Go for used infiniband hardware and aim for 10gb performance. 2) Stick with gig ethernet and buy some new switches (cisco or procurve) to create a storage-only ethernet LAN. Upgrade to 10gigE later but try to use hardware capable of it where possible to reduce upgrade costs. I have seen used, warrantied infiniband switches at reasonable prices (presumably because big companies are converging on 10gbit ethernet?) and the promise of cheap 10gb is attractive. I know nothing about IB, so here come the questions: Can I buy 2 x switches and have multiple HBAs in my xen and storage nodes to get redundancy and increased performance without complexity or expensive management software costs? If so, can you point me to some examples? Do NFS and iSCSI work just the same regardless? Is IB a sensible choice or could/should I use ethernet or FC on the same budget - I'm keen not to get boxed into a corner for future upgrades, however. For the storage I am likely to build a storage server using nexentastor with the intention that I can later add more disks, SSDs and add another server to provide a failover option at the storage level. An HP LeftHand starter SAN is also under consideration, too. Thanks in advance.

    Read the article

  • vmdk Recovery after migration from 3.5 to 4 and fallback tentative.

    - by olgirard
    Hy, I've tryed to migrate some VM from my 3.5i environment to a brand new vSphere 4.0 U1. The two platforms are running simultaneously, sharing the same SAN. I Migrate my VM by stopping it, unregistering in vcenter (esx ver. 3.5, i call it esx3), register in vSphere (esx ver. 4, i call it esx4), and migrate upgrade virtual hardware before powering it up (First mistake). vMotion was enabled on esx4, seem to be a second mistake. After a day or so, i encountred problems joigning the esx server (esx4) and decided to unregister my server for esx4 and fallback to esx3. esx3 refused to boot, i supposed this was due to virtual hardware in Version 7 so i recreated a new VM pointing to the vmdk of the old VM. Everithing seemed fine until i log into the server and discover that i was running on the original disk ith every snapshots ignored even those created on esx3. I tried to reboot VM on esx4 but VM doesn't power up because "The parent virtual disk has been modified since the child was created". I've got a copy of a later state of the drive but generated between two snapshots (ovf generated with canverter standalone) as a backup. Do i have a chance to recover at least some files on the virtual drive or (as i tink) all is played, i've done enought mistakes for this time. Thanks for your help.

    Read the article

  • Merging datasets with 2 different time variables in SAS

    - by John
    Hye Guys, for those regularly browsing this site sorry for already another question (however I did solve my last question myself!) I have another problem with merging datasets, it seems that accounting for time in datasets is a real pain in the ass. I succesfully managed to merge on months in my previous datasets, however it seems I have a final dataset which only has quarter as a time count variable. So where all my normal databases have month 1- xxx as an indicator of time, this database had quarter as an indicator of time. I still want to add the variables of this last database, let's call it TVOL, into my WORK database. Quick summary QUARTER: Quarter 0 = JAN1996-MAR1996 Month: Month 0 = JAN1996 Example: TVOL TVOL _ Ticker ____ Quarter 1500 _ AA ________ -1 52546 _ BB ________ 15 Example: WORK BETA _ Ticker ____ Month 1.52 _ AA ________ 2 1.54__ BB _______ 3 Example: Merged: BETA ______ TVOL __ Ticker ____ Month 1.52 _______ 500 ___ AA _______ 2 I now want to merge this 2 tables using following relationship if the month is in quarter 1, the data of quarter 0 has to be used, so if i have an observation i nWORK with date 2FEB1996 the TVOL of quarter -1 has to be put behind this observation. Something like IF month = quarter i use data quarter i-1. Also, as TVOL is measured quarterly and I have to put in monthly I have to take the average, so (TVOL/3) should be added as a variable. Thanks!

    Read the article

  • VMWare Raw Device Mapping Not Working

    - by George H. Lenzer
    While I'm waiting for VMWare support to get back to me, I thought I'd ask here. I have a 400 gig LUN presented from a fiber channel SAN to my VMWare host. It's legacy from another virtualization platform and I need to keep it as is to avoid a long period of downtime. I formatted my VMFS3 datastore with 4 meg blocks to allow up to 1 TB disks. Then I tried adding my 400 gig disk as a raw device in physical compatibility mode. I get the error: "File is larger than the maximum size supported by datastore 'Base Test'. [Base Test]VMTEST01/VMTEST01_2.vmdk Originally I had the VMFS datastore formatted with 1 meg blocks which was the cause of this problem since the largest disk allowed would be 256 gigs. But I deleted the data store and then reformatted with 4 megs blocks. I've also tried using virtual compatibility mode for the raw device but it still fails. Does anyone have any suggestions? I've been waiting for a little over a week for VMWare, but that's fine because I'm not yet a paying customer. I'm still in the eval phase.

    Read the article

  • What to look for in a switch with LAN/WAN verses an iSCSI SAN?

    - by Luke
    I'm setting up a VMWare ESXi 5 environment with 3 server nodes. Dell recommended 2x Force10 S60 switches shared (iSCSI SAN, LAN/WAN). The S60 switches are extremely powerful. They have 1.25 GB of buffer cache, < 9us latency. But they are very expensive (online price ~$15k per switch, actual quote a little less). I've been told that "by the book" you should at least have 2 internal switches for SAN, and 2 switches for LAN/WAN (each with a redundant). I know some of the pros and cons of each approach. What I'm wondering is, would it be more cost effective to disjoin the SAN from LAN with less expensive switches? The answer to this question highlights what I should be looking for in a switch for the SAN. What should I be looking for in a LAN/WAN switch, in comparison to the SAN? With the above linked question for the SAN: How is buffer latency measured? When you see 36 MB of buffer cache, is that shared or per port? So 36 MB would be 768kb or 36MB per port? With 3 to 6 servers how much buffer cache do you really need? What else should I be looking at? Our application will be heavily using HTML5 websockets (high number of persistent connections). The amount of data being sent is small; Data sent between client <- server isn't broadcasted (not a chat/IM service). We will be doing some database reporting too (csv export, sums, some joins). We are a small business and on a budget. We'd probably only be able to spend no more than $20k on switches total (2 or 4).

    Read the article

  • LSI 9211-8i won't boot in KVM

    - by Paul McMillan
    I'm running ubuntu 11.04 with an LSI 9211-8i in IT mode with the latest firmware (10). I'm using KVM with VT-d enabled to pass the entire PCIe device through to the guest OS. I have the device disabled in the system BIOS. When I boot my virtual machine, the adapter quits during bios initialization with the following error: Unable to load LSI Corporation MPT BIOS MPT BIOS Fault 0Ch encountered at adapter PCI(00h,04h,00h) Press any key to continue... I know the virtualization is correctly enabled. I've blacklisted the kernel modules in the host OS. Has anyone else encountered this error? I'm about out of ideas here. Edit: I contacted LSI tech support about this, and they suggested that I try RedHat and Xen. Apparently they don't test or support anything else.

    Read the article

  • How can a single disk in a hardware SATA RAID-10 array bring the entire array to a screeching halt?

    - by Stu Thompson
    Prelude: I'm a code-monkey that's increasingly taken on SysAdmin duties for my small company. My code is our product, and increasingly we provide the same app as SaaS. About 18 months ago I moved our servers from a premium hosting centric vendor to a barebones rack pusher in a tier IV data center. (Literally across the street.) This ment doing much more ourselves--things like networking, storage and monitoring. As part the big move, to replace our leased direct attached storage from the hosting company, I built a 9TB two-node NAS based on SuperMicro chassises, 3ware RAID cards, Ubuntu 10.04, two dozen SATA disks, DRBD and . It's all lovingly documented in three blog posts: Building up & testing a new 9TB SATA RAID10 NFSv4 NAS: Part I, Part II and Part III. We also setup a Cacit monitoring system. Recently we've been adding more and more data points, like SMART values. I could not have done all this without the awesome boffins at ServerFault. It's been a fun and educational experience. My boss is happy (we saved bucket loads of $$$), our customers are happy (storage costs are down), I'm happy (fun, fun, fun). Until yesterday. Outage & Recovery: Some time after lunch we started getting reports of sluggish performance from our application, an on-demand streaming media CMS. About the same time our Cacti monitoring system sent a blizzard of emails. One of the more telling alerts was a graph of iostat await. Performance became so degraded that Pingdom began sending "server down" notifications. The overall load was moderate, there was not traffic spike. After logging onto the application servers, NFS clients of the NAS, I confirmed that just about everything was experiencing highly intermittent and insanely long IO wait times. And once I hopped onto the primary NAS node itself, the same delays were evident when trying to navigate the problem array's file system. Time to fail over, that went well. Within 20 minuts everything was confirmed to be back up and running perfectly. Post-Mortem: After any and all system failures I perform a post-mortem to determine the cause of the failure. First thing I did was ssh back into the box and start reviewing logs. It was offline, completely. Time for a trip to the data center. Hardware reset, backup an and running. In /var/syslog I found this scary looking entry: Nov 15 06:49:44 umbilo smartd[2827]: Device: /dev/twa0 [3ware_disk_00], 6 Currently unreadable (pending) sectors Nov 15 06:49:44 umbilo smartd[2827]: Device: /dev/twa0 [3ware_disk_07], SMART Prefailure Attribute: 1 Raw_Read_Error_Rate changed from 171 to 170 Nov 15 06:49:45 umbilo smartd[2827]: Device: /dev/twa0 [3ware_disk_10], 16 Currently unreadable (pending) sectors Nov 15 06:49:45 umbilo smartd[2827]: Device: /dev/twa0 [3ware_disk_10], 4 Offline uncorrectable sectors Nov 15 06:49:45 umbilo smartd[2827]: Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error Nov 15 06:49:45 umbilo smartd[2827]: # 1 Short offline Completed: read failure 90% 6576 3421766910 Nov 15 06:49:45 umbilo smartd[2827]: # 2 Short offline Completed: read failure 90% 6087 3421766910 Nov 15 06:49:45 umbilo smartd[2827]: # 3 Short offline Completed: read failure 10% 5901 656821791 Nov 15 06:49:45 umbilo smartd[2827]: # 4 Short offline Completed: read failure 90% 5818 651637856 Nov 15 06:49:45 umbilo smartd[2827]: So I went to check the Cacti graphs for the disks in the array. Here we see that, yes, disk 7 is slipping away just like syslog says it is. But we also see that disk 8's SMART Read Erros are fluctuating. There are no messages about disk 8 in syslog. More interesting is that the fluctuating values for disk 8 directly correlate to the high IO wait times! My interpretation is that: Disk 8 is experiencing an odd hardware fault that results in intermittent long operation times. Somehow this fault condition on the disk is locking up the entire array Maybe there is a more accurate or correct description, but the net result has been that the one disk is impacting the performance of the whole array. The Question(s) How can a single disk in a hardware SATA RAID-10 array bring the entire array to a screeching halt? Am I being naïve to think that the RAID card should have dealt with this? How can I prevent a single misbehaving disk from impacting the entire array? Am I missing something?

    Read the article

  • How to configure multiple iSCSI Portal Groups on a EqualLogic PS6100?

    - by kce
    I am working on a migration from a VMware vSphere environment to a Hyper-V Cluster utilizing Windows Server 2012 R2. The setup is pretty small, an EqualLogic PS6100e and two Dell PowerConnect 5424 switches and handful of R710s and R620s. The SAN was configured as a non-RFC1918 network that is not assigned to our organization and since I am working on building a new virtualization environment I figured that this would be an appropriate time to do a subnet migration. I configured a separate VLAN and subnet on the switches and the two previously unused NICs on the PS6100's controllers. At this time I only have a single Hyper-V host cabled in but I can successfully ping the PS6100 from the host. From the PS6100 I can ping each of the four NICs that currently on the storage network. I cannot connect the Microsoft iSCSI Initiator to the Target. I have successfully added the Target Portals (the IP addresses of PS6100 NICs) and the Targets are discovered but listed as inactive. If I try to Connect to them I get the following error, "Log onto Target - Connection Failed" and ISCSIPrt 1 and 70 events are recorded in the Event Log. I have verified that access control to the volume is not the problem by temporarily disabling it. I suspect the problem is with the Portal Group IP address which is still listed as Group Address of old subnet (I know, I know I might be committing the sin of the X/Y problem but everything else looks good): RFC3720 has this to say about Network Portal and Portal Groups: Network Portal: The Network Portal is a component of a Network Entity that has a TCP/IP network address and that may be used by an iSCSI Node within that Network Entity for the connection(s) within one of its iSCSI sessions. A Network Portal in an initiator is identified by its IP address. A Network Portal in a target is identified by its IP address and its listening TCP port. Portal Groups: iSCSI supports multiple connections within the same session; some implementations will have the ability to combine connections in a session across multiple Network Portals. A Portal Group defines a set of Network Portals within an iSCSI Network Entity that collectively supports the capability of coordinating a session with connections spanning these portals. Not all Network Portals within a Portal Group need participate in every session connected through that Portal Group. One or more Portal Groups may provide access to an iSCSI Node. Each Network Portal, as utilized by a given iSCSI Node, belongs to exactly one portal group within that node. The EqualLogic Group Manager documentation has this to say about the Group IP Address: You use the group IP address as the iSCSI discovery address when connecting initiators to iSCSI targets in the group. If you modify the group IP address, you might need to change your initiator configuration to use the new discovery address Changing the group IP address disconnects any iSCSI connections to the group and any administrators logged in to the group through the group IP address. Which sounds equivalent to me (I am following up with support to confirm). I think a reasonable explanation at this point is that the Initiator can't complete the connection to the Target because the Group IP Address / Network Portal is on a different subnet. I really want to avoid a cutover and would prefer to run both subnets side-by-side until I can install and configure each Hyper-V host. Question/s: Is my assessment at all reasonable? Is it possible to configure multiple Group IP Addresses on the EqualLogic PS6100? I don't want to just change it as it will disconnect the remaining ESXi hosts. Am I just Doing It Wrong(TM)?

    Read the article

  • Statistics based marketing campaign measurement tools

    - by AFHood
    Currently using SAS as measurement engine and Business Objects as display layer. Looking to develop a new, faster, slicker solution. Has anyone developed or purchased a campaign measurement reporting system? This solution should measure everything from email stats, web stats, customer activity, lift, ROI, etc. Ok.. I'm researching and finding nada... We are working with a team from India and they want to re-write everything from scratch.. Any solutions out there at all?

    Read the article

  • Creating transparent gridlines

    - by Rob Penridge
    I'm trying to get the chart's gridlines to be transparent but it doesn't seem to be supported: http://support.sas.com/documentation/cdl/en/grstatug/63302/HTML/default/viewer.htm#n1f71f6e9v037an1jy274v66z4r1.htm I'm doing to try and blend the gridlines with the chart background color (which in my code can change between colors) which would make the gridlines subtle rather than jarring when background colors change. Here is my code: ** ** TAKE THE DEFAULT STYLE BEING USED. MODIFY IT SO THAT ** GRAPH GRIDLINES WILL BE GREEN AND MOSTLY TRANSPARENT *; proc template; define style my_style; parent = styles.default; style GraphGridLines from GraphGridLines / contrastcolor=green transparency=.05; end; run; ** ** LAYOUT TEMPLATE FOR A SIMPLE SERIES CHART *; proc template; define statgraph mychart; begingraph; layout overlay / wallcolor=black xaxisopts=(display=(line) griddisplay=on) yaxisopts=(display=(line)) ; seriesplot x=name y=height / lineattrs=(color=white); endlayout; endgraph; end; run; ** ** PLOT SAMPLE DATA USING CUSTOM STYLE AND CHART LAYOUT WE JUST DEFINED *; ods graphics / width=640 height=640 ; ods html style=my_style; proc sgrender data=sashelp.class template=mychart; run; ods html close; Is there another way to achieve this effect by blending the green color with the background color?

    Read the article

  • Proliant server will not accept new hard disks in RAID 1+0?

    - by Leigh
    I have a HP ProLiant DL380 G5, I have two logical drives configured with RAID. I have one logical drive RAID 1+0 with two 72 gb 10k sas 1 port spare no 376597-001. I had one hard disk fail and ordered a replacement. The configuration utility showed error and would not rebuild the RAID. I presumed a hard disk fault and ordered a replacement again. In the mean time I put the original failed disk back in the server and this started rebuilding. Currently shows ok status however in the log I can see hardware errors. The new disk has come and I again have the same problem of not accepting the hard disk. I have updated the P400 controller with the latest firmware 7.24 , but still no luck. The only difference I can see is the original drive has firmware 0103 (same as the RAID drive) and the new one has HPD2. Any advice would be appreciated. Thanks in advance Logs from server ctrl all show config Smart Array P400 in Slot 1 (sn: PAFGK0P9VWO0UQ) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (68.5 GB, RAID 1, Interim Recovery Mode) physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 73.5 GB, OK) physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 72 GB, Failed array B (SAS, Unused Space: 0 MB) logicaldrive 2 (558.7 GB, RAID 5, OK) physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 300 GB, OK) physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SAS, 300 GB, OK) physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 300 GB, OK) ctrl all show config detail Smart Array P400 in Slot 1 Bus Interface: PCI Slot: 1 Serial Number: PAFGK0P9VWO0UQ Cache Serial Number: PA82C0J9VWL8I7 RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: E Firmware Version: 7.24 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Cache Status Details: A cache error was detected. Run more information. Cache Ratio: 100% Read / 0% Write Drive Write Cache: Disabled Total Cache Size: 256 MB Total Cache Memory Available: 208 MB No-Battery Write Cache: Disabled Battery/Capacitor Count: 0 SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 0 MB Status: Failed Physical Drive Array Type: Data One of the drives on this array have failed or has Logical Drive: 1 Size: 68.5 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 17594 Strip Size: 128 KB Full Stripe Size: 128 KB Status: Interim Recovery Mode Caching: Enabled Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive0 Mount Points: C:\ 68.5 GB Logical Drive Label: A0100539PAFGK0P9VWO0UQ0E93 Mirror Group 0: physicaldrive 2I:1:2 (port 2I:box 1:bay 2, S Mirror Group 1: physicaldrive 2I:1:1 (port 2I:box 1:bay 1, S Drive Type: Data physicaldrive 2I:1:1 Port: 2I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 73.5 GB Rotational Speed: 10000 Firmware Revision: 0103 Serial Number: B379P8C006RK Model: HP DG072A9B7 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:2 Port: 2I Box: 1 Bay: 2 Status: Failed Drive Type: Data Drive Interface Type: SAS Size: 72 GB Rotational Speed: 15000 Firmware Revision: HPD9 Serial Number: D5A1PCA04SL01244 Model: HP EH0072FARUA PHY Count: 2 PHY Transfer Rate: Unknown, Unknown Array: B Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data Logical Drive: 2 Size: 558.7 GB Fault Tolerance: RAID 5 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 64 KB Full Stripe Size: 128 KB Status: OK Caching: Enabled Parity Initialization Status: Initialization Co Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive1 Mount Points: E:\ 558.7 GB Logical Drive Label: AF14FD12PAFGK0P9VWO0UQD007 Drive Type: Data physicaldrive 1I:1:5 Port: 1I Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE07QH300009923X1X3 Model: HP DG0300BALVP Current Temperature (C): 32 Maximum Temperature (C): 45 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:3 Port: 2I Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE0AHVH00009924P8F3 Model: HP DG0300BALVP Current Temperature (C): 34 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:4 Port: 2I Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE08NAK00009924KWD6 Model: HP DG0300BALVP Current Temperature (C): 35 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown

    Read the article

  • Android NDK r4 san-angeles problem

    - by Goz
    Hi All, I'm starting to learn the android NDK and I've instantly come up against a problem. I'e built the tool chain (which took a LOT longer than I was expecting!!) and I've compiled the C++ code with no problems and now I'm trying to build the java code. Instantly I come up against a problem. There is a file "main.xml" <?xml version="1.0" encoding="utf-8"?> <LinearLayout xmlns:android="http://schemas.android.com/apk/res/android" android:orientation="vertical" android:layout_width="match_parent" android:layout_height="match_parent" > <TextView android:layout_width="match_parent" android:layout_height="wrap_content" android:text="Hello World, DemoActivity" /> </LinearLayout> and I get the following errors: Description Resource Path Location Type error: Error: String types not allowed (at 'layout_height' with value 'match_parent'). main.xml /DemoActivity/res/layout line 2 Android AAPT Problem error: Error: String types not allowed (at 'layout_height' with value 'match_parent'). main.xml /DemoActivity/res/layout line 2 Android AAPT Problem error: Error: String types not allowed (at 'layout_width' with value 'match_parent'). main.xml /DemoActivity/res/layout line 2 Android AAPT Problem error: Error: String types not allowed (at 'layout_width' with value 'match_parent'). main.xml /DemoActivity/res/layout line 7 Android AAPT Problem error: Error: String types not allowed (at 'layout_width' with value 'match_parent'). main.xml /DemoActivity/res/layout line 7 Android AAPT Problem So I can see the problem lies in the fact that these "match_parent" strings are in there. Anyone know how to fix this?

    Read the article

  • Command View EVA Login Problem

    - by ngadimin
    I'm using Command View EVA version 9.01 on a Windows Storage Server 2003 R2. And all of a sudden I can't log in to the command view, it always say incorrect username or password, I haven't done any change on the password nor the system. Is there any way I can fix this?

    Read the article

  • Replicate / SYNC / Copy thousands of files

    - by rihatum
    Windows 32BIT Box (Server OS) 4GB RAM a 800GB LUN Mapped to the above box as a local drive Around 700GB of text files (Yes text files and a few thousand word documents) nested in thousands of directories. I need to move this to a new storage and map another server to it. What would be the best way to go about it ? What I did was mapped the existing LUN to our new box and mapped a LUN from the New storage to the new box too, and tried copying (windows copy) but that wasn't good / fast enough considering the downtime. I am now looking for either a script which will do this or a utility (prefer opensource / free) to move this size of data at a good speed. 2 x 1GB Nics teamed ether channel 2GBPs Any suggestions or pointers would be off great help Thanks !

    Read the article

< Previous Page | 8 9 10 11 12 13 14 15 16 17 18 19  | Next Page >