Search Results

Search found 2093 results on 84 pages for 'logical'.

Page 60/84 | < Previous Page | 56 57 58 59 60 61 62 63 64 65 66 67  | Next Page >

  • Formatting an HP ProLiant dl380 G4

    - by i.h4d35
    I have an old HP ProLiant dl380 G4 server whose hard disk needs to be formatted. Unfortunately, I cannot seem to do so. For one, it doesn't seem to be detecting any Hard Drives attached to the Server. The Hard Disks show up in the Ctrl+A option (SCSI Configuration Utility). Also, while inserting the SmartStart CD (7.01 or 7.04), it shows a message that no logical drives are found and there aren't any options to create one. Alternately I've tried slipstreaming the SCSI Driver into the OS but that doesn't seem to be helping. Also, I have a USB Floppy drive (for the SCSI driver) but that doesn't seem to be detected. Also, directly installing the OS (MS Server 2003 Standard Edition) obviously doesn't work (shows no hard disk found) Could anyone please advise as to what other needs to be done to format my server? Also please tell me what are the possible errors/mistakes which've been made so that I can learn from them. I went through some questions here on ServerFault and the HP guides here but they weren't of much help to a n00b like me. Thanks in Advance.

    Read the article

  • Steps after installing vCenter Server?

    - by goober
    I'm working with: Two new ESX servers that I'm configuring A new Server 2008 R2 machine that I'm using for vCenter. I took the following steps: Installed the Hypervisor on the 2 ESX machines Checked their setup/connectivity (appears to be fine; can ping, etc.) Installed vCenter Server on the Win2k8R2 box. This included the install of a SQL Express database (we're a small shop) FYI, I changed some of the ports (443 -- 8443, 80 --8080, etc.) Installed vCenter Web Client Server on the Win2k8R2 box Problems my vSphere Client on my Desktop fails to connect. Part of this is that it asks me for a username and password, but I don't recall specifying one when I set up the install. I receive the error "vSphere Client could not connect to [machinename]. An unknown connection error occurred. (The request failed because of a connection failure. (Unable to connect to the remote server))" I have also tried to use local machine admin credentials, including the format machinename\localuseracct. I have also tried using my domain credentials which are an admin for that box. I have also checked and the service is running. I also tried to connect via vSphere client locally installed on the server. It translates "localhost" to the correct name but gives the same error. I cannot register the vCenter server from the vCenter Web Client Server. I'm not sure if this is necessary, as they're both on the same machine, but it seems like the logical next step. I also receive a "failed to connect" error in this case as well. FYI, both the vCenter server and the vCenter Web Client Server are installed on the same Win2k8R2 server. What am I missing here? What is the best way to test in this case?

    Read the article

  • CD-ROM Cant Be Accessed After Installing VMware Tools on VMware Server 2.0.2

    - by Optimal Solutions
    Using VMware Server 2.02, I set up a new VM (Windows XP Pro) applied all of the updates, added Windows addons from the install CD, etc... I got it to a stable point and up through that point I was able to access the CD-ROM drive (E: on my host). What I never did before was install "VMware Tools" and since it claims to give better mouse and video support, I gave it a shot. What it does is it places the install package in a virtual CD-ROM drive. I ran the install, no errors and it wants a reboot. I log back in after reboot and pop in the install CD for Microsoft Office 2003 and I receive the message "Please Insert A Disc Into Drive D:". Drive D: would be the next logical drive after the C: drive where I chose to install the OS. The message box sits there and if I click "Cancel", to return to Windows Explorer, the status bar seems to blink ever 1/2 second - as if its polling for a CD-ROM drive or something. No bangs or exclamations in the Device Manager for any hardware. I had taken a snapshot prior to the VMware Tools install and upon restoring it, the CD-ROM is back. I made copies of two other VMs, installed the VMware Tools on those VMs and both experienced the same issues: Windows 2003 Server and Windows 7 (32-bit). Has anyone seen this issue and know of a fix for this? It would be nice to have the better graphics and better mouse control AND use my CD-ROM drive as well! Thank you.

    Read the article

  • Poor Write Performance in VM inside Proxmox PVE 2.0

    - by sorsenne
    I am running a PVE 2.0 on a decent Hardware (2 SATA HDDs as RAID1, 12GB RAM, i7 CPU) but the I/O Performance is very poor inside the VM (Ubuntu 11.10 Server). The very same VM was copied to another Server running simply Ubuntu Server with KVM and had better I/O Perf. this is how the HDD is shown in the Guest: ata1: SATA link up 6.0 Gbps (SStatus 133 SControl 300) ata1.00: ATA-8: ST3000DM001-9YN166, CC49, max UDMA/133 ata1.00: 5860533168 sectors, multi 16: LBA48 NCQ (depth 31/32), AA ata1.00: configured for UDMA/133 scsi 0:0:0:0: Direct-Access ATA ST3000DM001-9YN1 CC49 PQ: 0 ANSI: 5 sd 0:0:0:0: [sda] 5860533168 512-byte logical blocks: (3.00 TB/2.72 TiB) sd 0:0:0:0: [sda] 4096-byte physical blocks sd 0:0:0:0: [sda] Write Protect is off sd 0:0:0:0: [sda] Mode Sense: 00 3a 00 00 sd 0:0:0:0: [sda] Write cache: enabled, read cache: enabled, doesn't support DPO or FUA I tested with DD: $ dd bs=1M count=128 if=/dev/zero of=test conv=fdatasync 128+0 records in 128+0 records out 134217728 bytes (134 MB) copied, 19.2222 s, 7.0 MB/s on the Host, this same Test will result with 156 MB/s in average. PS: I am using VirtIO and see no error in dmesg.

    Read the article

  • How do you monitor SSD wear in Windows when the drives are presented as 'generic' devices?

    - by MikeyB
    Under Linux, we can monitor SSD wear fairly easily with smartmontools whether the drive is presented as a normal block device or a generic device (which happens when the drive has been hardware RAIDed by certain controllers such as the one on the IBM HS22). How can we do the equivalent under Windows? Does anyone actually use smartmontools? Or are there other packages out there? The problem is that SCSI Generic devices just don't show up in Windows. If the drives aren't RAIDed we can see them fine. How I'd do it in Linux: sles11-live:~ # lsscsi -g [1:0:0:0] disk SMART USB-IBM 8989 /dev/sda /dev/sg0 [2:0:0:0] disk ATA MTFDDAK256MAR-1K MA44 - /dev/sg1 [2:0:1:0] disk ATA MTFDDAK256MAR-1K MA44 - /dev/sg2 [2:1:8:0] disk LSILOGIC Logical Volume 3000 /dev/sdb /dev/sg3 sles11-live:~ # smartctl -l ssd /dev/sg1 smartctl 5.42 2011-10-20 r3458 [x86_64-linux-2.6.32.49-0.3-default] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net Device Statistics (GP Log 0x04) Page Offset Size Value Description 7 ===== = = == Solid State Device Statistics (rev 1) == 7 0x008 1 26~ Percentage Used Endurance Indicator |_ ~ normalized value sles11-live:~ # smartctl -l ssd /dev/sg2 smartctl 5.42 2011-10-20 r3458 [x86_64-linux-2.6.32.49-0.3-default] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net Device Statistics (GP Log 0x04) Page Offset Size Value Description 7 ===== = = == Solid State Device Statistics (rev 1) == 7 0x008 1 3~ Percentage Used Endurance Indicator |_ ~ normalized value

    Read the article

  • Resource Monitor (resmon) in Windows Server 2008 R2

    - by Clever Human
    In Windows Server 2008 R2's Resource Monitor, is there a way to set the scale of the various graphs to be constant values instead of variable based on data? It seems to me that the utility of a graph is to get a quick overview glance at the values those graphs are showing. So if I look at the CPU graph and the line is up near the top, I can know immediately that something is using all my CPU and go investigate what. I don't really care if the CPU is jumping between .01% and 2%. Or if the network usage monitor is up near the top, I will know that all my bandwidth is being used up, and go figure out what. But the way things are now, the graphs are meaningless because the scales constantly shift. If you look at the network usage graph in one second it might have a scale out of 100kbps, and the next second have a scale based on 1mbps! So... is there a registry key or something that will peg the scale of these graphs to logical maximums? (the graph on the right hand side of the screenshot below):

    Read the article

  • Very slow write performance on Debian 6.0 (AMD64) with DMCRYPT/LVM/RAID1

    - by jdelic
    I'm seeing very strange performance characteristics on one of my servers. This server is running a simple two-disk software-RAID1 setup with LVM spanning /dev/md0. One of the logical volumes /dev/vg0/secure is encrypted using dmcrypt with LUKS and mounted with the sync and noatimes flag. Writing to that volume is incredibly slow at 1.8 MB/s and the CPU usage stays near 0%. There are 8 crpyto/1-8 processes running (it's a Intel Quadcore CPU). I hope that someone on serverfault has seen this before :-(. uname -a 2.6.32-5-xen-amd64 #1 SMP Tue Mar 8 00:01:30 UTC 2011 x86_64 GNU/Linux Interestingly, when I read from the device I get good performance numbers: reading without encryption: $ dd if=/dev/vg0/secure of=/dev/null bs=64k count=100000 100000+0 records in 100000+0 records out 6553600000 bytes (6.6 GB) copied, 68.8951 s, 95.1 MB/s reading with encryption: $ dd if=/dev/mapper/secure of=/dev/null bs=64k count=100000 100000+0 records in 100000+0 records out 6553600000 bytes (6.6 GB) copied, 69.7116 s, 94.0 MB/s However, when I try to write to the device: $ dd if=/dev/zero of=./test bs=64k 8809+0 records in 8809+0 records out 577306624 bytes (577 MB) copied, 321.861 s, 1.8 MB/s Also, when I read I see CPU usage, when I write, the CPU stays at almost 0% usage. Here is output of cryptsetup luksDump: LUKS header information for /dev/vg0/secure Version: 1 Cipher name: aes Cipher mode: cbc-essiv:sha256 Hash spec: sha1 Payload offset: 2056 MK bits: 256 MK digest: dd 62 b9 a5 bf 6c ec 23 36 22 92 4c 39 f8 d6 5d c1 3a b7 37 MK salt: cc 2e b3 d9 fb e3 86 a1 bb ab eb 9d 65 df b3 dd d9 6b f4 49 de 8f 85 7d 3b 1c 90 83 5d b2 87 e2 MK iterations: 44500 UUID: a7c9af61-d9f0-4d3f-b422-dddf16250c33 Key Slot 0: ENABLED Iterations: 178282 Salt: 60 24 cb be 5c 51 9f b4 85 64 3d f8 07 22 54 d4 1a 5f 4c bc 4b 82 76 48 d8 a2 d2 6a ee 13 d7 5d Key material offset: 8 AF stripes: 4000 Key Slot 1: DISABLED Key Slot 2: DISABLED Key Slot 3: DISABLED Key Slot 4: DISABLED Key Slot 5: DISABLED Key Slot 6: DISABLED Key Slot 7: DISABLED

    Read the article

  • How to configure SCSI hard drives and RAID for Poweredge 2850 web server

    - by Saul
    I'm trying to set up a Poweredge 2850 as a web server, but as a server novice it's causing me some confusion. Its a virgin install so no data to be lost as yet, so I'd like to get the best arrangement for setting up Windows Server 2008. The box will run IIS, a mail and FTP server. The current physical arrangement of the hot swap drives is 1 73GB 3 146GB 5 blank 0 73GB 2 146GB 4 146GB (but flashes green, amber off) When I enter the PERC config screens on boot up I've got Raid Ch- 0 ID 0 ONLIN A00-00 1 ONLIN A00-01 2 ONLIN A01-00 3 ONLIN A01-01 4 HOTSP I think that drives 0 and 1 are set to RAID 1 and drives 2 and 3 are also set to RAID 1, certainly I can see 2 logical drives, both raid 1 of 69880MB and 139900MB Now what I think I am getting here is that the 2 73GB drives mirror each other and the 2 146GB drives mirror 2? so by my noob thinking if a drive fails I can pull it, insert and new one and it will reduplicate from its matching pair? I think the flashing amber probably indicates a failing drive in slot 4, should that just be binned? What confuses me coming from a home user XP background is that when I load up Windows Server 2008 OS under my computer I only see a C drive of about 70GB capacity. i.e wheres the 146GB drive? Any advice appreciated

    Read the article

  • How do you automatically close 3rd party applications when LiberKey is shut down?

    - by NoCatharsis
    Within LiberKey, I have added my own portable applications that are not included within the LiberKey library. When you go into the Properties menu for the app in the LiberKey UI, the Advanced tab has an option for Autoexecute. This dropdown menu seems to have no visible effect, at least on my current installation. I found that I could right click within the primary GUI and select "Add software group", add all 3rd party applications, then go to the Advanced tab within THAT Properties screen and select Autoexecute - "Always on startup". This solved the problem for starting the apps when LiberKey starts. However, now I'm having the same issue when closing out LiberKey. I have created a new 3rd party app that calls the same .exe, but sends the Parameter "/close". I then went to the Advanced tab and selected Autoexecute - "Always on shutdown". Seems pretty logical right? But the apps will not close on LiberKey shutdown. I cannot handle the app close-outs in the same way with a software group, as I did with the startup issue because the Autoexecute drop-down does not have an "Always on shutdown" option. Unfortunately, many of the Q&A forums on liberkey.com are in French and I took Spanish in high school. Otherwise I've not been able to find a workable answer. Any suggestions?

    Read the article

  • RAID Volume is no longer showing in Raid Controller BIOS and in Windows

    - by Gordon
    Hi all, I have installed some critical Windows Updates yesterday and now my external RAID Volume no longer shows in Windows Vista x64. All updates went through successfully. For their description, I cannot see how they should relate to the issue, but this is the only change that happened, so who knows. Anyway, here is the details: I have an external eSata enclosure that is running on a SiI4726 controller. I can connect to the controller with it's management utility from the computer the enclosure is connected to. The three drives in the enclosure show up as JBODs. I had those drives configured to be one logical RAID5 drive. RAID management is done through a SiI3132 SoftRaid controller. The Raid Management Utility just shows empty channels where it usually shows the Raid Group. In the Windows Disk Manager, I can see an unknown unitialized device. This is fine according to the setup manual. What it doesn't show is my Raid drive. It's gone. Also, when booting Windows, the BIOS of the controller used to show the RAID volume before booting the OS. This is not happening anymore. Updating drivers and firmware did not help. I have made sure the drivers and firmware are compatible to each others. And like I said, it used to work before. Any clues?

    Read the article

  • HTML tabindex: Put some links last without complete enumeration

    - by Emanuel Berg
    I know I can use the HTML anchor attribute tabindex to set the tabindex of links, i.e., in what order they get focused when the user hits Tab (or Shift-Tab). But, I have a home page with tons of links, and to enumerate all those is a lot of work. The actual case is, I have four image links that by default gets index 1, 2, 3, and 4 (well, the behavior is equivalent, at least). But, I'd much rather have the first non-image link as number 1. Check it out here and you'll understand immediately. I tried to give the first non-image link (the link I desire to have tabindex 1) - I tried to give it tabindex 1 explicitly, hoping that it would cascade from there, but it didn't (i.e., the first image link got implicit tabindex 2). I also tried to give the image links ridiculously high tabindexes, but that didn't work: as the other links didn't have tabindexes at all, those highs were still "first". As a last resort (the solution currently employed) I gave the image links all tabindex -1. That makes for logical tabbing, but, it is suboptimal, as those image links are excluded from the tab loop - a user tabbing away will probably never realize that the images are clickable. I'd like them to be reachable with tabbing, but last, after all the ordinary links. If you wonder why I'm so determined to achieve this, it has to do with my own finger habits: I almost exclusively search for links, tab back, tab forth, etc., and very seldom using the mouse. Note: I'll accept a script to change the actual HTML for a complete enumeration, if you convince me there is no "set" way to solve this problem.

    Read the article

  • NFS high CPU usage

    - by user269836
    Hello, I have a very strange issue. I have next server: Intel(R) Xeon(TM) MP CPU 3.16GHz cat /proc/cpuinfo | grep proce | wc -l 8 free -m total used free shared buffers cached Mem: 28203 27606 596 0 10789 9714 -/+ buffers/cache: 7103 21100 Swap: 24695 0 24695 RAID card *-storage description: RAID bus controller product: MegaRAID vendor: LSI Logic / Symbios Logic physical id: 7 bus info: pci@0000:13:07.0 logical name: scsi2 version: 01 width: 32 bits clock: 66MHz capabilities: storage pm bus_master cap_list rom configuration: driver=megaraid latency=32 resources: irq:134 memory:d8ff0000-d8ffffff(prefetchable) memory:df600000-df60ffff(prefetchable) HDD: 10x148Gb SCSI U320 15k - RAID5 /dev/sdb1 807G 674G 93G 88% /storage /dev/sdb1 /storage ext4 defaults,usrjquota=aquota.user,grpjquota=aquota.group,jqfmt=vfsv0,noatime,nodiratime,noacl,errors=remount-ro 0 1 network cards ethtool -i eth0 driver: tg3 version: 3.116 firmware-version: 5704-v3.36, ASFIPMIc v2.36 bus-info: 0000:10:02.0 ethtool -i eth1 driver: tg3 version: 3.116 firmware-version: 5704-v3.36, ASFIPMIc v2.36 bus-info: 0000:10:02.0 ifconfig bond0 Link encap:Ethernet HWaddr 00:0f:1f:ff:d6:4d inet addr:192.168.15.71 Bcast:192.168.15.255 Mask:255.255.255.0 inet6 addr: fe80::20f:1fff:feff:d64d/64 Scope:Link UP BROADCAST RUNNING MASTER MULTICAST MTU:1500 Metric:1 RX packets:1062818202 errors:0 dropped:3918 overruns:0 frame:0 TX packets:1041317321 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:10000 RX bytes:258867684559 (241.0 GiB) TX bytes:396569192650 (369.3 GiB) this server running only nfs-kernel-server uname -a Linux nas2-backup 2.6.32-5-amd64 #1 SMP Sun Sep 23 10:07:46 UTC 2012 x86_64 GNU/Linux Debian 6. What do I have, once per day or two, LA goes up, it can be reached around LA: 40 but if I do: nfs-kernel-server restart. Every thing is OK. But on the next day or a little bit later, LA goes up again. Servers are connected to d-link dgs 1016d with 24 GBits ports. I have tried everything to find out what the problem is. Why it's happening, but still I can not resolve this issue. Any ideas on what is happening here?

    Read the article

  • Gray Progress Bar in Macbook Boot caused by Partition Fault

    - by Konstantin Bodnya
    Here's my problem: When I try to load my macbook it shows the gray progress bar. It takes a while to fill the whole progress and after it macbook just shuts down. I tried to boot from recovery partition and run Disk Utility to repair it. Disk Utility showed my "Macintosh HD" in a gray color and failed to repair it. I thought all my data was lost, but then I tried the following: So I booted into ubunto from live usb and it successfully mounted my macintosh hd hfs+ partition. Parted shows me the following partitions on my disk: Disk /dev/sda: 500GB Sector size (logical/physical): 512B/512B Partition Table: gpt Number Start End Size File system Name Flags 1 20.5kB 210MB 210MB fat32 EFI System Partition boot 2 210MB 499GB 499GB hfs+ Macintosh HD 3 499GB 500GB 650MB hfs+ Recovery HD Seems legit except for FAT32 for EFI System Partition. Since all my data is okay and backed up what should I do to recover the system. I don't really want to reinstall all the system though I believe there's a command to make it allright in linux. Thank you everyone!

    Read the article

  • Geographically distributed file system with preferred locality

    - by dpb
    Hi All -- I'm building a application that needs to distribute a standard file server across a few sites over a WAN. Basically, each site needs to write a lot of misc files of varying size (some in the 100s MB range, but most small), and the application is written such that collisions aren't a problem. I'd like to have a system set up that meets the following qualifications: Each site can store files in a shared "namespace". That is, all the files would show up in the same filesystem. Each site would not send data over the WAN unless necessary. I.e., there would be local storage on each side of the WAN that would be "merged" into the same logical filesystem. Linux & Free ($$$) is a must. Basically, something like a central NFS share would meet most of the requirements, however it would not allow the locally written data to stay local. All data from remote sides of the WAN would be copied locally all the time. I have looked into Lustre, and have run some successful tests with it, however, it appears to distribute files fairly uniformly across the distributed storage. I have dug through the documentation and have not found anything that automatically will "prefer" local storage over remote storage. Even something that went with the lowest latency storage would be fine. It would work most of the time, which would meet this application's requirements. Any ideas?

    Read the article

  • CentOS OpenVZ fail to boot after kernel update

    - by SkechBoy
    After upgrading to latest OpenVZ kernel CentOS server won't boot. When i try go boot the latest kernel server is stuck at this point: (note that images are taken from virtual kvm) http://i.stack.imgur.com/4lusz.jpg Then i try to start the server on some old kernels and than i get this error message: kernel panic - not syncing - attempted to kill init better shown on this image: http://i.stack.imgur.com/2SReF.jpg Here is some useful information fdisk -l WARNING: GPT (GUID Partition Table) detected on '/dev/sda'! The util fdisk doesn't support GPT. Use GNU Parted. Disk /dev/sda: 2995.7 GB, 2995739688960 bytes 255 heads, 63 sectors/track, 364211 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x0004c4e4 Device Boot Start End Blocks Id System /dev/sda1 1 523 4199044+ 82 Linux swap / Solaris /dev/sda2 524 785 2104515 83 Linux /dev/sda3 786 261869 2097157230 83 Linux /dev/sda4 261870 364211 822062115 83 Linux /etc/fstab proc /proc proc defaults 0 0 none /dev/pts devpts gid=5,mode=620 0 0 /dev/sda1 none swap sw 0 0 /dev/sda2 /boot ext3 defaults 0 0 /dev/sda3 / ext3 defaults 0 0 /dev/sda4 /home ext3 defaults 0 0 and grub config file: title OpenVZ (2.6.18-274.18.1.el5.028stab098.1) root (hd0,1) kernel /vmlinuz-2.6.18-274.18.1.el5.028stab098.1 ro root=/dev/sda3 vga=0x317 selinux=0 initrd /initrd-2.6.18-274.18.1.el5.028stab098.1.img title OpenVZ (2.6.18-274.7.1.el5.028stab095.1) root (hd0,1) kernel /vmlinuz-2.6.18-274.7.1.el5.028stab095.1 ro root=/dev/sda3 vga=0x317 selinux=0 initrd /initrd-2.6.18-274.7.1.el5.028stab095.1.img title OpenVZ (2.6.18-194.8.1.el5.028stab070.4) root (hd0,1) kernel /vmlinuz-2.6.18-194.8.1.el5.028stab070.4 ro root=/dev/sda3 vga=0x317 initrd /initrd-2.6.18-194.8.1.el5.028stab070.4.img Any help is greatly appreciated Thanks.

    Read the article

  • a disk read error occurred

    - by kellogs
    Hi, ¨a disk read error occurred¨ appears on screen after choosing to boot into Windows XP from GRUB. [root@localhost linux]# fdisk -lu Disk /dev/sda: 160.0 GB, 160041885696 bytes 255 heads, 63 sectors/track, 19457 cylinders, total 312581808 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x48424841 Device Boot Start End Blocks Id System /dev/sda1 63 204214271 102107104+ 7 HPFS/NTFS Partition 1 does not end on cylinder boundary. /dev/sda2 204214272 255606783 25696256 af HFS / HFS+ Partition 2 does not end on cylinder boundary. /dev/sda3 255606784 276488191 10440704 c W95 FAT32 (LBA) Partition 3 does not end on cylinder boundary. /dev/sda4 276490179 312576704 18043263 5 Extended /dev/sda5 * 276490240 286709759 5109760 83 Linux /dev/sda6 286712118 310488254 11888068+ b W95 FAT32 /dev/sda7 310488318 312576704 1044193+ 82 Linux swap / Solaris sda is a 160GB hard disk with quite a few partitions and 3 OSes installed. I am able to boot into Linux and Mac OS fine, but not into Windows anymore. The Windows system is located on /dev/sda1. I can not recall how exactly have I used testdisk but it once said that ¨The harddisk /dev/sda (160GB / 149 GB) seems too small! (< 172GB / 157GB)¨ or something simillar. So far I have tried to ¨fixboot¨ and ¨chkdsk¨ from a recovery console on the affected windows partition (/dev/sda1), the plug off power cord for 15 seconds trick, reinstalling GRUB, repairing the MFT and boot sector of the affected partition via testdisk, what next please ? Thank you!

    Read the article

  • Dual-booting Ubuntu and Pardus with GRUB2...Pardus no show?

    - by Ibn Ali al-Turki
    Hello all, I have Ubuntu 10.10 installed and used to dual-boot Fedora, but I replaced Fedora with Pardus. After the install, I went into ubuntu, and did a sudo update-grub. It detected my Pardus 2011 install there. When I rebooted, it did not show up in my grub2 menu however. I went back to Ubuntu and did it again...then checked the grub.cfg, and it is not there. I have read that Pardus uses a grub legacy. How can I get Pardus into my grub2 menu? Thanks! sudo fdisk -l Disk /dev/sda: 500.1 GB, 500107862016 bytes 255 heads, 63 sectors/track, 60801 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0xd9b3496e Device Boot Start End Blocks Id System /dev/sda1 * 1 15197 122067968 83 Linux /dev/sda2 36394 60802 196059757 5 Extended /dev/sda3 15197 30394 122067968 83 Linux /dev/sda5 36394 59434 185075308 7 HPFS/NTFS /dev/sda6 59434 60802 10983424 82 Linux swap / Solaris Partition table entries are not in disk order and update-grub Found linux image: /boot/vmlinuz-2.6.35-25-generic Found initrd image: /boot/initrd.img-2.6.35-25-generic Found memtest86+ image: /boot/memtest86+.bin Found Pardus 2011 (2011) on /dev/sda3 Yet after this, I go to grub.cfg, and Pardus is not there.

    Read the article

  • Debian: Should I add vlan interface into bridge for KVM?

    - by javano
    I am setting up a Debian Squeeze box as a KVM host. I want to add multiple interfaces to each KVM guest so I want them to be on different VLANs. After reading about this, I believe the best method is to add multiple logical VLAN (sub)-interfaces to the physical NICs and then create a bridge adapter for each VLAN interace, and assign each bridge as a NIC for KVM guests. Does this make good sense, or madness? Do I have to use bridged interfaces with KVM like this? Can't I just add eth1.xx and eth1.yy to my interfaces config below and then configure those directly as bridged KVM guest NICs? If so, how should this look in the interfaces config file below? user@host:~$ cat /etc/network/interfaces # This file describes the network interfaces available on your system # and how to activate them. For more information, see interfaces(5). # The loopback network interface auto lo iface lo inet loopback # Management Interface auto eth0 iface eth0 inet static address 172.22.0.31 netmask 255.255.255.0 gateway 172.22.0.1 # Interface for guest VMs auto eth1 # Guest1 : Use VLAN 117 auto eth1.117 iface eth1.117 inet manual # Set up br1 for guest 1, bridging with vlan 117 auto br1.117 iface br1.117 inet manual bridge_ports eth1.117 bridge_stp off user@host:~$ uname -a Linux hostname 3.4.9 #1 SMP Wed Aug 22 19:08:46 BST 2012 x86_64 GNU/Linux UPDATE I would really like it if someone could clarify the config for me, as I have also seen the above configured with this syntax, so I don't see why one would be preferred over the other; # Interface for guest VMs auto eth1 allow-hotplug eth1 iface eth1 inet static # Vlan 117 for guest 1 auto vlan 117 iface vlan111 inet static vlan_raw_device eth1 # Guest 1 : NIC 1 auto br1.117 iface br1.117 inet manual bridge_ports vlan117 bridge_stp off

    Read the article

  • Best way to attach 96 tb to workstation

    - by user994179
    I'm running a workstation with dual xeon 5690's (12 physical/24 logical cores), 192 gb of ram (ie, maxed-out), Windows 7 64bit, 5 slots for adapter cards, and 1 tb of internal storage, with 5 more internal bays available. I have an app that creates data files totaling about 88 tbs. These are written once every 14 months, and the rest of the time the app only needs to read them; and 95% of the reads are sequential reads of huge chunks of data. I have some control over how big the individual files are, but ideally they would be between 5 and 8 tbs. The app will be reading from only one drive at a time, and the nature of the data is such that if (when) a drive dies I can restore the data to a new disk from tape. While it would be nice to be able to use the fastest drive/controllers available, at this point size matters more than speed. After doing lots of reading, I am leaning toward buying a bunch of cheap 2tb drives and putting them into a bunch of cheap enclosures. All this stuff is going into my home office, so I need to avoid the raised floor/refrigerated approach. My questions: Is the cheap drive/enclosure solution the best one for this situation? Given the nature of the app and the way the data is used, does RAID make sense? If so, which one? For huge sequential reads, would Usb 3.0 and eSata be a wash performance-wise? For each slot available on the workstation, can I hook up an enclosure that can hold multiple drives? Or is it one controller per drive? If I can have multiple drives on one controller, am I essentially splitting the bandwidth (throughput)? For example, if I have a 12 bay enclosure, is the throughput of the controller reduced by a factor of 12? Are there any Windows 7 volume/drive/capacity limits I should be aware of? Thanks

    Read the article

  • Expand disk space on Ubuntu 10.04 (VMWare Guest)

    - by Jason Clawson
    I need to resize the disk space of an ubuntu guest in VMWare Workstation. After using the expand disk utility in vmware workstation, I need to do some linux magic to resize the parition. I have searched and found a lot of posts about resizing it. Unfortunately I don't really understand it all that well. Can anyone help me out with this? df -h gives me: Filesystem Size Used Avail Use% Mounted on /dev/mapper/ubuntu-root 19G 2.6G 16G 15% / none 496M 172K 495M 1% /dev none 500M 0 500M 0% /dev/shm none 500M 64K 500M 1% /var/run none 500M 0 500M 0% /var/lock none 500M 0 500M 0% /lib/init/rw none 19G 2.6G 16G 15% /var/lib/ureadahead/debugfs /dev/sda1 228M 36M 181M 17% /boot lvs says: LV VG Attr LSize Origin Snap% Move Log Copy% Convert root ubuntu -wi-ao 18.88g swap_1 ubuntu -wi-ao 884.00m fdisk -l says: Disk /dev/sda: 21.5 GB, 21474836480 bytes 255 heads, 63 sectors/track, 2610 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00033718 Device Boot Start End Blocks Id System /dev/sda1 * 1 32 248832 83 Linux Partition 1 does not end on cylinder boundary. /dev/sda2 32 2611 20719617 5 Extended /dev/sda5 32 2611 20719616 8e Linux LVM I really appreciate the help.

    Read the article

  • Utility to LOGICALLY compare two xml files?

    - by Matthew
    Right now we are attempting to build golden configurations for our environment. One piece of software that we use relies on large XML files to contain the bulk of its configuration. We want tot ake our lab environment, catalog it as our "golden configuration" and then be able to audit against that configuration in the future. Since diff is bytewise comparison and NOT logical comparison, we can't use it to compare files in this case (XML is unordered, so it won't work). What I am looking for is something that can parse the two XML files, and compare them element by element. So far we have yet to find any utilities that can do this. OS doesn't matter, I can do it on anything where it will work. The preference is something off the shelf. Any ideas? Edit: One issue we have run into is one vendor's config files will occasionally mention the same element several times, each time with different attributes. Whatever diff utility we use would need to be able to identify either the set of attributes or identify them all as part of one element. Tall order :)

    Read the article

  • Laptop hangs on POST and does not finish except on rare occasions

    - by user1049697
    I have an old Toshiba Satellite A100 laptop that hangs on POST when I try to start it. On rare occasions it does finish the POST and boots Windows successfully, but most times it just finishes it partially and continues to hang. I can enter the BIOS though when it has frozen, but I have to open the DVD-drive first for some reason. The keyboard is not quite right either, and I can't navigate the BIOS properly because the arrow keys doesn't work. I tried an external keyboard, but the problem persisted. I have tried to remove the memory, hard drive, and battery to see if any of these were the problem, but it did not solve it. The one logical thing left to do would be to remove the CMOS battery, but the "brilliant" engineers at Toshiba have place it such that a complete disassembly of the machine is necessary. What this all boils down to is basically the question of whether I can "save" this machine and get it to boot properly, or if I should just send it off to recycling. I suspect it might need costly repairs, but I can't bring myself to throw it away before I have made sure it's completely dead.

    Read the article

  • Question About mk-table-checksum Results

    - by stevenmusumeche
    Hello, I have 1 master and 2 slaves. I am using MySQL 5.1.42 on all servers. I am attempting to use mk-table-checksum to verify that their data is in sync, but I am getting unexpected results on one of the slaves. First, I generate the checksums on the master like this: mk-table-checksum h=localhost --databases MYDB --tables {$table_list} --replicate=MYDB.mk_checksum --chunk-size=10M My understanding is that this runs the checksum queries on the master which then propagate via normal replication to the slaves. So, no locking is needed because the slaves will be at the same logical point in time when they run the checksum queries on themselves. Is this correct? Next, to verify that the checksums match, I run this on the master: mk-table-checksum --databases MYDB --replicate=IRC.mk_checksum --replicate-check 1 h=localhost,u=maatkit,p=xxxx If there are any differences, I repair the slaves like this: mk-table-sync --execute --verbose --replicate IRC.mk_checksum h=localhost,u=maatkit,p=xxxx After doing all of this, I repaired both slaves with mk-table-sync. However, everytime I run this sequence (after everything has already been repaired), one slave is perfectly in sync but one slave always has a few tables out of sync. I am 99.999% sure that the data on the slaves matches, since I repaired everything and the tables were not even updated on the master between runs of the checksum script. What would cause a few tables to always show out of sync on only one of the slaves? I am stuck. Here is the output: Differences on h=x.x.x.x,p=...,u=maatkit DB TBL CHUNK CNT_DIFF CRC_DIFF BOUNDARIES IRC product 10 0 1 product_id = 147377 AND product_id < 162085 IRC post_order_survey 0 0 1 1=1 IRC mk_heartbeat 0 0 1 1=1 IRC mailing_list 0 0 1 1=1 IRC honey_pot_log 0 0 1 1=1 IRC product 12 0 1 product_id = 176793 AND product_id < 191501 IRC product 18 0 1 product_id = 265041 IRC orders 26 0 1 order_id = 694472 IRC orders_product 6 0 1 op_id = 935375

    Read the article

  • Degraded RAID-5 array with lvm2 lost superblock and partition table

    - by Fred Phillips
    I have a RAID-5 array of 4x1TB hard disks with one lvm2 partition on Ubuntu Linux 10.04 LTS. One of the disks has failed. I have re-assembled the array without this failed disk but now mdadm --examine claims the array has no superblock and fdisk says it has no partition table. What can I do to recover the data? # mdadm -D /dev/md0 /dev/md0: Version : 1.2 Creation Time : Sat Mar 5 14:43:49 2011 Raid Level : raid5 Array Size : 2930276352 (2794.53 GiB 3000.60 GB) Used Dev Size : 976758784 (931.51 GiB 1000.20 GB) Raid Devices : 4 Total Devices : 4 Persistence : Superblock is persistent Update Time : Sat Mar 5 15:06:49 2011 State : clean, degraded Active Devices : 3 Working Devices : 3 Failed Devices : 1 Spare Devices : 0 Layout : left-symmetric Chunk Size : 512K Name : boba:1 (local to host boba) UUID : 52eb4bc9:c3d8aab5:e0699505:e0e1aa05 Events : 18 Number Major Minor RaidDevice State 0 8 1 0 active sync /dev/sda1 1 8 65 1 active sync /dev/sde1 2 8 49 2 active sync /dev/sdd1 3 0 0 3 removed 4 8 17 - faulty spare /dev/sdb1 # mdadm --examine /dev/md0 mdadm: No md superblock detected on /dev/md0. # fdisk -l /dev/md0 Disk /dev/md0: 3000.6 GB, 3000602984448 bytes 2 heads, 4 sectors/track, 732569088 cylinders Units = cylinders of 8 * 512 = 4096 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 524288 bytes / 1572864 bytes Disk identifier: 0x00000000 Disk /dev/md0 doesn't contain a valid partition table # cat /proc/mdstat Personalities : [raid6] [raid5] [raid4] [linear] [multipath] [raid0] [raid1] [raid10] md0 : active raid5 sdb1[4](F) sda1[0] sdd1[2] sde1[1] 2930276352 blocks super 1.2 level 5, 512k chunk, algorithm 2 [4/3] [UUU_] unused devices: <none>

    Read the article

  • SSD Drive not being recongized in BIOS

    - by chobo2
    Well I bought my first drive Mushkin Chronos 180GB and got it installed in my computer and loaded up. I went to windows 7 and initialized the drive and then I installed "SSDlife Free" and loaded it up and my the SSD drive came up said it was "powered on 3 times"(thought it was odd but then thought maybe some testing???). I then restarted my computer and loaded into Acronis. Went to my SSD drive and make a partition called windows(made a basic logical partition). I then loaded up Norton ghost and wanted to copy my current windows onto the SSD drive on the partition I made found out I could not do it through the recovery disk so I made a backup of my windows drive and wanted to then restore it onto the SSD drive. Came back an hour later when the backup was done. I tried to restore the it on my SSD drive and could not find the partition so I loaded up Acronis again and it did not see it. I then went to the bios and saw only my other hard drive. What I tried Tried uplugging and replugging in both sata and power cables. Tried using the power and sata cable from the working drive and giving it the ones that SSD drive were using. Tried Sata AHCI Mode (Intel ICH9 Southbridge) Tried SATA PORT0-1 NATIVE MODE (Intel ICH9 Southbridge) Nothing worked. Software / hardware Windows 7 ultimate Gigabyte S-Series GA-P35-DS3L Mother board I hope someone has some ideas on why it is not being recognized.

    Read the article

< Previous Page | 56 57 58 59 60 61 62 63 64 65 66 67  | Next Page >