Search Results

Search found 7843 results on 314 pages for 'power over ethernet'.

Page 62/314 | < Previous Page | 58 59 60 61 62 63 64 65 66 67 68 69  | Next Page >

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • how do i fix this: the networking and wireless are enabled. but list of networks under wireless networks not available

    - by Ayesha Ahmad
    i started working with ubuntu 11.10 last year. i upgraded to 12.04 a week back. since then i have had all sorts of problems with network connection. first had to install the new driver. the hardware switch somehow got disabled then the above problem arrived. even tho the options are all enabled, the OS is not able to detect scan available network connections. also i have to bring to notice that once in a while it does get connected, can not explain how it happens. I want to fix this problem once and for all. please help. ifconfig: eth0 Link encap:Ethernet HWaddr f0:4d:a2:51:b3:c8 UP BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) Interrupt:44 eth1 Link encap:Ethernet HWaddr 1c:65:9d:67:d5:e1 inet6 addr: fe80::1e65:9dff:fe67:d5e1/64 Scope:Link UP BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:170 TX packets:0 errors:27 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) Interrupt:17 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:344 errors:0 dropped:0 overruns:0 frame:0 TX packets:344 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:20336 (20.3 KB) TX bytes:20336 (20.3 KB) lshw -c network *-network description: Wireless interface product: BCM4313 802.11b/g/n Wireless LAN Controller vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:03:00.0 logical name: eth1 version: 01 serial: 1c:65:9d:67:d5:e1 width: 64 bits clock: 33MHz capabilities: bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=wl0 driverversion=5.100.82.38 latency=0 multicast=yes wireless=IEEE 802.11 resources: irq:17 memory:f0500000-f0503fff *-network description: Ethernet interface product: AR8152 v1.1 Fast Ethernet vendor: Atheros Communications Inc. physical id: 0 bus info: pci@0000:04:00.0 logical name: eth0 version: c1 serial: f0:4d:a2:51:b3:c8 capacity: 100Mbit/s width: 64 bits clock: 33MHz capabilities: bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=atl1c driverversion=1.0.1.0-NAPI firmware=N/A latency=0 multicast=yes port=twisted pair resources: irq:44 memory:f0400000-f043ffff ioport:2000(size=128) iwconfig lo no wireless extensions. eth1 IEEE 802.11 Access Point: Not-Associated Link Quality:5 Signal level:0 Noise level:196 Rx invalid nwid:0 invalid crypt:0 invalid misc:0 eth0 no wireless extensions. lspci 00:00.0 Host bridge: Intel Corporation Core Processor DRAM Controller (rev 18) 00:02.0 VGA compatible controller: Intel Corporation Core Processor Integrated Graphics Controller (rev 18) 00:16.0 Communication controller: Intel Corporation 5 Series/3400 Series Chipset HECI Controller (rev 06) 00:1a.0 USB controller: Intel Corporation 5 Series/3400 Series Chipset USB2 Enhanced Host Controller (rev 06) 00:1b.0 Audio device: Intel Corporation 5 Series/3400 Series Chipset High Definition Audio (rev 06) 00:1c.0 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 1 (rev 06) 00:1c.1 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 2 (rev 06) 00:1c.5 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 6 (rev 06) 00:1d.0 USB controller: Intel Corporation 5 Series/3400 Series Chipset USB2 Enhanced Host Controller (rev 06) 00:1e.0 PCI bridge: Intel Corporation 82801 Mobile PCI Bridge (rev a6) 00:1f.0 ISA bridge: Intel Corporation Mobile 5 Series Chipset LPC Interface Controller (rev 06) 00:1f.2 SATA controller: Intel Corporation 5 Series/3400 Series Chipset 6 port SATA AHCI Controller (rev 06) 00:1f.3 SMBus: Intel Corporation 5 Series/3400 Series Chipset SMBus Controller (rev 06) 00:1f.6 Signal processing controller: Intel Corporation 5 Series/3400 Series Chipset Thermal Subsystem (rev 06) 03:00.0 Network controller: Broadcom Corporation BCM4313 802.11b/g/n Wireless LAN Controller (rev 01) 04:00.0 Ethernet controller: Atheros Communications Inc. AR8152 v1.1 Fast Ethernet (rev c1) ff:00.0 Host bridge: Intel Corporation Core Processor QuickPath Architecture Generic Non-core Registers (rev 05) ff:00.1 Host bridge: Intel Corporation Core Processor QuickPath Architecture System Address Decoder (rev 05) ff:02.0 Host bridge: Intel Corporation Core Processor QPI Link 0 (rev 05) ff:02.1 Host bridge: Intel Corporation Core Processor QPI Physical 0 (rev 05) ff:02.2 Host bridge: Intel Corporation Core Processor Reserved (rev 05) ff:02.3 Host bridge: Intel Corporation Core Processor Reserved (rev 05) I hope this information is of some help.

    Read the article

  • Wireless doesn't work on a Broadcom BCM4312

    - by Boderick
    As stated, I've just upgraded to 12.04 and my Dell Inspiron 1545 isn't recognising its wireless card and I was wondering if anybody could help? Edit: Okay, so I found the wireless card by using lspci -vvv and it returned this: 0c:00.0 Network controller: Broadcom Corporation BCM4312 802.11b/g LP-PHY (rev 01) Subsystem: Dell Wireless 1397 WLAN Mini-Card Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR+ FastB2B- DisINTx- Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast TAbort- SERR- Kernel modules: ssb lsmod Module Size Used by dm_crypt 22528 0 joydev 17393 0 dell_wmi 12601 0 sparse_keymap 13658 1 dell_wmi dell_laptop 13671 0 dcdbas 14098 1 dell_laptop psmouse 72919 0 uvcvideo 67203 0 serio_raw 13027 0 videodev 86588 1 uvcvideo snd_hda_codec_idt 60251 1 mac_hid 13077 0 snd_hda_intel 32765 5 snd_hda_codec 109562 2 snd_hda_codec_idt,snd_hda_intel snd_hwdep 13276 1 snd_hda_codec parport_pc 32114 0 rfcomm 38139 0 bnep 17830 2 ppdev 12849 0 snd_pcm 80845 3 snd_hda_intel,snd_hda_codec bluetooth 158438 10 rfcomm,bnep snd_seq_midi 13132 0 snd_rawmidi 25424 1 snd_seq_midi snd_seq_midi_event 14475 1 snd_seq_midi snd_seq 51567 2 snd_seq_midi,snd_seq_midi_event snd_timer 28931 2 snd_pcm,snd_seq snd_seq_device 14172 3 snd_seq_midi,snd_rawmidi,snd_seq binfmt_misc 17292 1 snd 62064 18 snd_hda_codec_idt,snd_hda_intel,snd_hda_codec,snd_hwdep,snd_pcm,snd_rawmidi,snd_seq,snd_timer,snd_seq_device soundcore 14635 1 snd snd_page_alloc 14108 2 snd_hda_intel,snd_pcm lp 17455 0 parport 40930 3 parport_pc,ppdev,lp sky2 53628 0 ums_realtek 17920 0 uas 17699 0 i915 414603 3 wmi 18744 1 dell_wmi drm_kms_helper 45466 1 i915 drm 197692 4 i915,drm_kms_helper i2c_algo_bit 13199 1 i915 video 19068 1 i915 usb_storage 39646 1 ums_realtek ifconfig -a eth0 Link encap:Ethernet HWaddr 00:23:ae:24:71:45 inet addr:192.168.1.158 Bcast:192.168.1.255 Mask:255.255.255.0 inet6 addr: fe80::223:aeff:fe24:7145/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:14340 errors:0 dropped:0 overruns:0 frame:0 TX packets:10191 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:15403754 (15.4 MB) TX bytes:1262570 (1.2 MB) Interrupt:18 ham0 Link encap:Ethernet HWaddr 7a:79:05:2d:b0:f7 inet addr:5.45.176.247 Bcast:5.255.255.255 Mask:255.0.0.0 inet6 addr: fe80::7879:5ff:fe2d:b0f7/64 Scope:Link inet6 addr: 2620:9b::52d:b0f7/96 Scope:Global UP BROADCAST RUNNING MULTICAST MTU:1404 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:179 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:500 RX bytes:0 (0.0 B) TX bytes:27480 (27.4 KB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:433 errors:0 dropped:0 overruns:0 frame:0 TX packets:433 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:60051 (60.0 KB) TX bytes:60051 (60.0 KB) iwconfig lo no wireless extensions. ham0 no wireless extensions. eth0 no wireless extensions. the results for sudo lshw -class network *-network description: Wireless interface product: BCM4312 802.11b/g LP-PHY vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:0c:00.0 logical name: eth1 version: 01 serial: 00:22:5f:77:1f:e6 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=wl0 driverversion=5.100.82.38 latency=0 multicast=yes wireless=IEEE 802.11bg resources: irq:17 memory:f69fc000-f69fffff *-network description: Ethernet interface product: 88E8040 PCI-E Fast Ethernet Controller vendor: Marvell Technology Group Ltd. physical id: 0 bus info: pci@0000:09:00.0 logical name: eth0 version: 13 serial: 00:23:ae:24:71:45 size: 100Mbit/s capacity: 100Mbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=sky2 driverversion=1.30 duplex=full firmware=N/A ip=192.168.1.158 latency=0 link=yes multicast=yes port=twisted pair speed=100Mbit/s resources: irq:45 memory:f68fc000-f68fffff ioport:de00(size=256) *-network description: Ethernet interface physical id: 2 logical name: ham0 serial: 7a:79:05:2d:b0:f7 size: 10Mbit/s capabilities: ethernet physical configuration: autonegotiation=off broadcast=yes driver=tun driverversion=1.6 duplex=full firmware=N/A ip=5.45.176.247 link=yes multicast=yes port=twisted pair speed=10Mbit/s and the results of rfkill list all 0: brcmwl-0: Wireless LAN Soft blocked: yes Hard blocked: yes 1: dell-wifi: Wireless LAN Soft blocked: yes Hard blocked: yes

    Read the article

  • "The connection has timed out" - Please help!

    - by gon
    I recently installed a fresh Ubuntu 12.04 LTS on a desktop, and the installation itself was successful (other than 'grub rescue' issue that I encountered but fixed) but this connection problem is really giving me a headache. Symptoms: 1. When I open the FireFox browser and try to connect to a website, it just hangs for a while saying "Connecting..." but eventually loads an error page "The connection has timed out". 2. It's not a browser problem (and I tried setting ipv6 thing to "true" at about:config) because running "sudo apt-get install [some-random-package]" at terminal fails ("E: Unable to locate package [package]") too. All other operations that need internet access are not working. 3. I certainly see a wired network (called "eth1") at the Network Manager, and it says "Connection Established" after disconnecting and then connecting again. I have tried almost everything that could be found from google search results still no luck. Their problems slightly differ from mine or the solutions just don't work. By the way it didn't have internet access when installing Ubuntu 12.04. (I ignored the message that I need internet to install Ubuntu) Could this be a problem? I'm sorry I don't remember if internet worked or not on the previous version of Ubuntu. :( I would really appreciate your help... I don't even know what more to do if this fails too.. Thanks!! Thanks for your comment. Here is the result of ifconfig: eth0 Link encap:Ethernet HWaddr 78:ac:c0:3d:b2:b9 inet addr:10.10.65.185 Bcast:10.10.65.255 Mask:255.255.255.0 inet6 addr: fe80::7aac:c0ff:fe3d:b2b9/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:3907 errors:0 dropped:0 overruns:0 frame:0 TX packets:771 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:393118 (393.1 KB) TX bytes:73472 (73.4 KB) Interrupt:16 eth1 Link encap:Ethernet HWaddr 78:ac:c0:3d:b2:b8 UP BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) Interrupt:17 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:4 errors:0 dropped:0 overruns:0 frame:0 TX packets:4 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:204 (204.0 B) TX bytes:204 (204.0 B) route -n: Kernel IP routing table Destination Gateway Genmask Flags Metric Ref Use Iface 0.0.0.0 10.10.65.1 0.0.0.0 UG 0 0 0 eth0 10.10.65.0 0.0.0.0 255.255.255.0 U 1 0 0 eth0 169.254.0.0 0.0.0.0 255.255.0.0 U 1000 0 0 eth0 /etc/resolv.conf: # Dynamic resolv.conf(5) file for glibc resolver(3) generated by resolvconf(8) # DO NOT EDIT THIS FILE BY HAND -- YOUR CHANGES WILL BE OVERWRITTEN nameserver 8.8.8.8 nameserver 8.8.4.4 nameserver 10.81.1.8 nameserver 10.1.2.10 nameserver 127.0.0.1 search yamatake.local /etc/network/interfaces: auto lo iface lo inet loopback #auto eth0 #iface eth0 inet dhcp #auto eth1 #iface eth1 inet dhcp And I'll also include the result of 'sudo lshw -C network' in case it might help: *-network description: Ethernet interface product: NetXtreme BCM5764M Gigabit Ethernet PCIe vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:02:00.0 logical name: eth0 version: 10 serial: 78:ac:c0:3d:b2:b9 size: 100Mbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm vpd msi pciexpress bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=tg3 driverversion=3.121 duplex=full firmware=5764m-v3.35 ip=10.10.65.185 latency=0 link=yes multicast=yes port=twisted pair speed=100Mbit/s resources: irq:93 memory:fc000000-fc00ffff *-network description: Ethernet interface product: NetXtreme BCM5764M Gigabit Ethernet PCIe vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:01:00.0 logical name: eth1 version: 10 serial: 78:ac:c0:3d:b2:b8 size: 100Mbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm vpd msi pciexpress bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=tg3 driverversion=3.121 duplex=full firmware=5764m-v3.35 latency=0 link=no multicast=yes port=twisted pair speed=100Mbit/s resources: irq:94 memory:fb000000-fb00ffff

    Read the article

  • Can't Get Mac Mini to turn on - no screen, no beep, only the fan, power light, and optical drive noi

    - by pibyers
    I have an Intel-based Mac mini mid-2007 (Model A1176). This is the computer my kids use so I don't use it regularly. The computer had been working fine until one day my kids told me that it no longer works. The computer will not boot up. When I turn it on the fan turns, the white power light in the front turns on, and there is a sound that appears to be from the optical drive (rather than hard drive). I don't get anything to the monitor, nor do I get any dings or other start up sounds from the computer. Here is what I've tried thus far to no avail: 1) Swapped out the monitors early on since I figured that was my weak link - no change 2) Reset the PMU - no change 3) Tried to boot up from the System Disk - The mini loaded the dvd into the drive, but nothing else (I can't eject the disk so I can put it back) 3) Start up the computer in target mode connected to another mac - I tried this too, but I never received a chime or the disk show up on the other mac. I'm about out of ideas apart from scraping the computer. Does anyone have any ideas that I can try? Again, nothing has been done to the computer in at least 6 months when I upgraded the RAM. I'm also still on Leopard. Thanks.

    Read the article

  • What can I do to prevent system power downs?

    - by Joe King
    Yesterday I was given my brother's old laptop - core i7, 2.67GHz, 8GB RAM, 128GB SSD, Win7 64 bit. It's a Sony Vaio Z11. Approx 18 months old. When running something computationally intensive, the fan starts up and after about 30 secs it just powers itself down with no warning. I guess it is overheating. There is nothing in the event logs to suggest what is causing it - the only thing I see is "the last system shutdown was unexpected" or something similar. This is a problem for me because I use a lot of number crunching apps, which pretty much makes it useless to me. I would like to know if there is anything I can do, other than the obvious things I've done already - open up and clean out dust, re-install the OS. According to my brother, this problem started about 6 months ago when it was already outside warranty. If it's just used for simple things - web browsing, word processing etc, the problem does not occur. Any ideas for what I can do to fix this ? Update: I found that the laptop has 2 hardware settings for graphics: Speed and Stamina - the Speed setting seems to use an nvidia GEforce GT 330M, while the Stamina setting uses an Intel chipset. With the setting on Speed, I can hear the fan the whole time, and the system powers down after a short while (5-10 mins) even just doing basic tasks (browsing this site for example), but doesn't shut down if I just leave it switched on. In this mode it also sometimes just freezes the screen and I have to power off myself. However on Stamina setting it only powers down when doing number crunching and never freezes the screen.

    Read the article

  • Is there a way to force the monitor to power off in Windows 8?

    - by Rune Jacobsen
    I have googled this a bit and looked at powrprof.dll and PsShutdown but I haven't found a way to do exactly what I want to do. You know that power save option that lets Windows turn off your monitor(s) if you haven't touched the system for x amount of time? Well, I have a PC that needs to be on most of the day (and night), and I have to watch it much of the time, so I can't have a short timeout for automatically turning off the monitor. However, once I leave it for a few hours (happens at varying times of the day), I would like to be able to issue a command that puts the computer in this mode. Not sleep mode, not hibernate mode. Monitor off, that is all. I realize of course I could just turn the physical monitor off. That is not what I want. This Dell monitor takes forever to display a picture from a cold state. If it is turned off by the computer not sending a signal - not so bad. Is there any way for me to do this? As mentioned, the OS can do it, so I would find it really useful if I could do it too. :)

    Read the article

  • How to network a Mac running System 7.6 with Mac OS X 10.6 or Windows Vista over Ethernet?

    - by Brian Teeter
    The title pretty much says it all. I have a Powerbook 540c that is connected to my network via Ethernet. It has no Internet tools on it at all, and its running System 7.6. I am trying to figure out a way to get it to mount a drive on either my Windows Vista workstation or my Snow Leopard Macbook. Once I do that I can get an old browser on there and get what I need off the Internet. Thus far I have not been able to get it connected. Microsoft dropped Appletalk support in XP and despite enabling Appletalk on my Macbook, the powerbook cannot see it in the Chooser. Any ideas?

    Read the article

  • Pull network or power? (for contianing a rooted server)

    - by Aleksandr Levchuk
    When a server gets rooted (e.g. a situation like this), one of the first things that you may decide to do is containment. Some security specialists advise not to enter remediation immediately and to keep the server online until forensics are completed. Those advises are usually for APT. It's different if you have occasional Script kiddie breaches. However, you may decide to remediate (fix things) early and one of the steps in remediation is containment of the server. Quoting from Robert Moir's Answer - "disconnect the victim from its muggers". A server can be contained by pulling the network cable or the power cable. Which method is better? Taking into consideration the need for: Protecting victims from further damage Executing successful forensics (Possibly) Protecting valuable data on the server Edit: 5 assumptions Assuming: You detected early: 24 hours. You want to recover early: 3 days of 1 systems admin on the job (forensics and recovery). The server is not a Virtual Machine or a Container able to take a snapshot capturing the contents of the servers memory. You decide not to attempt prosecuting. You suspect that the attacker may be using some form of software (possibly sophisticated) and this software is still running on the server.

    Read the article

  • How to Grab MAC Address of Active Ethernet Connection in Bash Script?

    - by Huy Tran
    Simple Question: How do I grab the MAC address of the active Ethernet connection in a bash script? I currently have: set - `/sbin/ifconfig eth0 | head -1` MAC=$5 Which outputs the MAC address of the eth0, but if it's eth1 that's active, I want that instead. Could I beforehand execute ifconfig | grep inet but that wouldn't tell me which interface is active, just that one is active. I need to grab the line above it to tell me which one is the active connection. Any help would be much appreciated. Thank you!

    Read the article

  • Running two graphics cards (non-SLI) to power 3D on two different monitors?

    - by Delameko
    Hi, I'm a bit clueless about this, so excuse my naivety. I have two video cards, a Nvidia 8800 and a GT120, powering three monitors. I run two 3D game instances (two Everquest 2 clients), one on each of my first two monitors. It's been running fine, although sometimes it sounds like the computer is trying to take off. Today I realised that I was actually playing them on the two monitors that are both powered by the 8800. Thinking that I might as well make use of the power of both cards I tried switching the monitor cables over so that each card would be "powering" one of the clients. (Is it silly to assume this is how it works?) This doesn't seem to have had the desired effect, as the client running on the 8800 screen is running worse than it was before. Is it even possible to run two clients on separate GPUs? Is SLI the only way to utilise 2 GPUs? Is there something special I have to do? Or do I have to set the client to use a particular GPU (an option I can't seem to find in EQ2)? I run the clients in window mode if that makes any difference, and I'm running Win 7. Thanks.

    Read the article

  • Atheros Wireless card shows up as two different models?

    - by geermc4
    Hi I've been fighting these wireless drivers for a few days and just recently i noticed that the model the Wireless controller appears in lspci is different sometimes. This is the data i have after installing Ubuntu Server 64 bit ~# lspci -k .... 04:00.0 Network controller: Atheros Communications Inc. AR9285 Wireless Network Adapter (PCI-Express) (rev 01) Subsystem: AzureWave Device 1d89 Kernel driver in use: ath9k Kernel modules: ath9k ran some updates, restarted, all was good, all though it did say that linux-headers-server linux-image-server linux-server where beeing kept back. After that i installed ubuntu-desktop (aptitude install ubuntu-desktop --without-recommends) restarted and not only is the wireless not working anymore, but the hardware is listed as a different card ~# lspci -k .... 04:00.0 Ethernet controller: Atheros Communications Inc. AR5008 Wireless Network Adapter (rev 01) has no available drivers for it, still i tried to modprobe ath9k, they show up in lsmod as loaded, but still iw list shows nothing. this is what it looked like before the ubuntu-desktop instalation Wiphy phy0 Band 1: Capabilities: 0x11ce HT20/HT40 SM Power Save disabled RX HT40 SGI TX STBC RX STBC 1-stream Max AMSDU length: 3839 bytes DSSS/CCK HT40 Maximum RX AMPDU length 65535 bytes (exponent: 0x003) Minimum RX AMPDU time spacing: 8 usec (0x06) HT TX/RX MCS rate indexes supported: 0-7 Frequencies: * 2412 MHz [1] (14.0 dBm) * 2417 MHz [2] (15.0 dBm) * 2422 MHz [3] (15.0 dBm) * 2427 MHz [4] (15.0 dBm) * 2432 MHz [5] (15.0 dBm) * 2437 MHz [6] (15.0 dBm) * 2442 MHz [7] (15.0 dBm) * 2447 MHz [8] (15.0 dBm) * 2452 MHz [9] (15.0 dBm) * 2457 MHz [10] (15.0 dBm) * 2462 MHz [11] (15.0 dBm) * 2467 MHz [12] (15.0 dBm) (passive scanning) * 2472 MHz [13] (14.0 dBm) (passive scanning) * 2484 MHz [14] (17.0 dBm) (passive scanning) Bitrates (non-HT): * 1.0 Mbps * 2.0 Mbps (short preamble supported) * 5.5 Mbps (short preamble supported) * 11.0 Mbps (short preamble supported) * 6.0 Mbps * 9.0 Mbps * 12.0 Mbps * 18.0 Mbps * 24.0 Mbps * 36.0 Mbps * 48.0 Mbps * 54.0 Mbps max # scan SSIDs: 4 max scan IEs length: 2257 bytes Coverage class: 0 (up to 0m) Supported Ciphers: * WEP40 (00-0f-ac:1) * WEP104 (00-0f-ac:5) * TKIP (00-0f-ac:2) * CCMP (00-0f-ac:4) * CMAC (00-0f-ac:6) Available Antennas: TX 0x1 RX 0x3 Configured Antennas: TX 0x1 RX 0x3 Supported interface modes: * IBSS * managed * AP * AP/VLAN * WDS * monitor * mesh point * P2P-client * P2P-GO software interface modes (can always be added): * AP/VLAN * monitor interface combinations are not supported Supported commands: * new_interface * set_interface * new_key * new_beacon * new_station * new_mpath * set_mesh_params * set_bss * authenticate * associate * deauthenticate * disassociate * join_ibss * join_mesh * remain_on_channel * set_tx_bitrate_mask * action * frame_wait_cancel * set_wiphy_netns * set_channel * set_wds_peer * connect * disconnect Supported TX frame types: * IBSS: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 * managed: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 * AP: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 * AP/VLAN: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 * mesh point: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 * P2P-client: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 * P2P-GO: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 Supported RX frame types: * IBSS: 0x00d0 * managed: 0x0040 0x00d0 * AP: 0x0000 0x0020 0x0040 0x00a0 0x00b0 0x00c0 0x00d0 * AP/VLAN: 0x0000 0x0020 0x0040 0x00a0 0x00b0 0x00c0 0x00d0 * mesh point: 0x00b0 0x00c0 0x00d0 * P2P-client: 0x0040 0x00d0 * P2P-GO: 0x0000 0x0020 0x0040 0x00a0 0x00b0 0x00c0 0x00d0 Device supports RSN-IBSS. What's with the hardware change? If it has 2, how can i make the AR9285 always load and disable AR5008, or, is it the same and it's just showing it different? :| Oh and I've tried this on Ubuntu 10.04 server, xubuntu 12.04, ubuntu 12.04 desktop and server. Thanks in advanced. -- Here's some more info, i have it setup in 2 hard drives, 1 works and the other one i'm using to figure it out The one that works... # lshw -class network *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:03:00.0 logical name: eth0 version: 06 serial: 54:04:a6:a3:3b:96 size: 1Gbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=full firmware=rtl_nic/rtl8168e-2.fw ip=192.168.2.147 latency=0 link=yes multicast=yes port=MII speed=1Gbit/s resources: irq:43 ioport:e000(size=256) memory:d0004000-d0004fff memory:d0000000-d0003fff *-network description: Wireless interface product: AR9285 Wireless Network Adapter (PCI-Express) vendor: Atheros Communications Inc. physical id: 0 bus info: pci@0000:04:00.0 logical name: wlan0 version: 01 serial: 74:2f:68:4a:26:73 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=ath9k driverversion=3.2.0-18-generic-pae firmware=N/A latency=0 link=no multicast=yes wireless=IEEE 802.11bgn resources: irq:18 memory:fea00000-fea0ffff Here's where it doesn't # lshw -class network *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:03:00.0 logical name: eth0 version: 06 serial: 54:04:a6:a3:3b:96 size: 1Gbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=full firmware=rtl_nic/rtl8168e-2.fw ip=192.168.2.160 latency=0 link=yes multicast=yes port=MII speed=1Gbit/s resources: irq:43 ioport:e000(size=256) memory:d0004000-d0004fff memory:d0000000-d0003fff *-network UNCLAIMED description: Ethernet controller product: AR5008 Wireless Network Adapter vendor: Atheros Communications Inc. physical id: 0 bus info: pci@0000:04:00.0 version: 01 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list configuration: latency=0 resources: memory:fea00000-fea0ffff Update I've noticed that if i blacklist the ath9k and ath9k_common modules lspci gives me the AR9285, but then I need to modprobe ath9k for it to work, does this make any sense? If so, why?

    Read the article

  • How to generate and encode (for use in GA), random, strict, binary rooted trees with N leaves?

    - by Peter Simon
    First, I am an engineer, not a computer scientist, so I apologize in advance for any misuse of nomenclature and general ignorance of CS background. Here is the motivational background for my question: I am contemplating writing a genetic algorithm optimizer to aid in designing a power divider network (also called a beam forming network, or BFN for short). The BFN is intended to distribute power to each of N radiating elements in an array of antennas. The fraction of the total input power to be delivered to each radiating element has been specified. Topologically speaking, a BFN is a strictly binary, rooted tree. Each of the (N-1) interior nodes of the tree represents the input port of an unequal, binary power splitter. The N leaves of the tree are the power divider outputs. Given a particular power divider topology, one is still free to map the power divider outputs to the array inputs in an arbitrary order. There are N! such permutations of the outputs. There are several considerations in choosing the desired ordering: 1) The power ratio for each binary coupler should be within a specified range of values. 2) The ordering should be chosen to simplify the mechanical routing of the transmission lines connecting the power divider. The number of ouputs N of the BFN may range from, say, 6 to 22. I have already written a genetic algorithm optimizer that, given a particular BFN topology and desired array input power distribution, will search through the N! permutations of the BFN outputs to generate a design with compliant power ratios and good mechanical routing. I would now like to generalize my program to automatically generate and search through the space of possible BFN topologies. As I understand it, for N outputs (leaves of the binary tree), there are $C_{N-1}$ different topologies that can be constructed, where $C_N$ is the Catalan number. I would like to know how to encode an arbitrary tree having N leaves in a way that is consistent with a chromosomal description for use in a genetic algorithm. Also associated with this is the need to generate random instances for filling the initial population, and to implement crossover and mutations operators for this type of chromosome. Any suggestions will be welcome. Please minimize the amount of CS lingo in your reply, since I am not likely to be acquainted with it. Thanks in advance, Peter

    Read the article

  • What is the point of PPPoE?

    - by aaa90210
    I am trying to expand my knowledge of networking beyond the basics. I have started reading about PPP, and how it is used in DSL modems with PPPoE and PPPoA. My first impression of PPP was "well that seems pretty similar to Ethernet". They are both data link layer protocols. They both have fields to identify the encapsulated protocol (e.g. IP). They both have related protocols to assign IP addresses (DHCP and NCP). So my first question was "so what's the point of PPP, why not just use Ethernet?". The answer to that was fairly straightforward - Ethernet is not supported over a wide range of media like serial lines, and is a fairly specific technology to LAN's using CAT5 or similar. HOWEVER - then I was reading about PPPoE, and the obvious thought was "well if we are doing something over Ethernet, then Ethernet must be available and in use, so why not just use it?". In other words, PPPoE seems to be encapsulating one data-link layer protocol in another very similar protocol. Why do IP-inside-PPP-inside-Ethernet when we could just be doing IP-inside-Ethernet, and use DHCP rather than NCP to assign the IP address to the home router? Thanks

    Read the article

  • Laptop battery holds charge, but won't charge any more.

    - by Jeff
    Ok, I'm sure I will need to replace either my battery or my AC adapter, but would rather not buy one if the other is the problem. My problem is. I have a Sager laptop that gets quite a bit of use. The charging has always been a little bit odd. If I was in the process of using it, it would charge just fine and stay On AC power. If I left it alone, however(power settings to ONLY turn off the monitor) in either Ubuntu or Windows 7 it decides that it didn't want to use AC power anymore and would just start draining the battery until it died. Now, suddenly, it won't charge at all. The capacity was great up to this point which happened in an instant. It will recognize the battery but won't see the AC power if plugged in while the battery is in. I can power up the laptop without the battery and it works fine. If I plug in the battery while powered up it will claim it's charging it, but it stays at the same percentage. If I unplug the power, it will switch over to Battery fine, but I have to power down and unplug the battery to get it back on AC power. I've had dying/dead batteries before but they typically won't hold a full charge anymore but it still winds up to 100% then drops quickly when unplugged. This seems more like a chip problem in the battery to me, but I'm not sure. Any ideas?

    Read the article

  • Resolving loss of internet bandwidth in home network

    - by Caspar
    Recently, I've decided to connect my laptop at home to my modem/router through Ethernet cables built into my apartment. As these built-in Ethernet cables are usable via plugs built into the walls (called powerline adapters), I use some additional cabling (STP CAT6 cables) from my laptop/router to the plugs. In addition, I don't know any technical details about these built-in cables (as they're not visible), only the maximal bandwidth (1 GBit = Cat6?) that they're supporting. The built-in cables are Cat. 5e Ethernet cables. The problem is now that when I set up the connection, I cannot use the full bandwidth that my internet connection is actually offering (100 Mbit/s), only about 85 Mbit/s between 85 - 88 Mbit/s, despite the fact that all cables involved should support the maximal bandwidth. I know from other tests with one of the Ethernet cables in use that I can use almost 99 Mbit/s when I connect my laptop directly to the router/modem using only this one cable. In addition, it is very unlikely that the length of the resulting cable connection from my laptop to my router involving the built-in cables exceeds 100 m. So, what possible reasons for this loss of bandwidth exist? And how I can fix this issue? I hope this might help resolve the issue: The built-in cables appear to be Cat. 5e Ethernet cables. So, is there any problem when I connect Cat6 Ethernet cables directly to Cat5e Ethernet cables via the plugs?

    Read the article

  • How to add dynamic profile fields in Invision Power Board?

    - by user361908
    I run a game server and want to link the persons in game character name and stats to Invision Power Board. I've setup IPB so players currently login with their in game login. That means their username on the forum is the same as their username for the game. They can have multiple characters on 1 account so ideally I'd like to allow them to choose a main character and display an actual image of that character and allow them to display other characters if they are online. Currently I'm doing something like this by hacking profileFields.php but it's messy and not very efficient on the user or server end. My code currently uses 2 custom fields which the player can enter their character names in. To display only their main character they enter the name in the first field. To also display other characters if they are online they enter the same name into the second field. To resolve the IDs I have to run a lot of queries. I know PHP but I am not familiar with IPBs code at all. I just need pointed in a direction where I can combine the 2 fields into 1 field. tl;dr: Here is my setup: Invision Power Board 3 Data is stored in MySQL on the same server the forum is hosted on. Usernames on the forum are identical to usernames in the game Here is a breakdown of what I'd like to do: In the edit profile section I need to resolve the forum username to the games account id then: Display a list of characters and allow them to choose which characters they want to display if they are online as well as a default character that will be displayed if none are online. In the posts user info pane: Display the online character or the default if none are online. Here is what I need to know: How to generate a list of characters in the profile edit form and allow selection (checkbox) of each character to display as well as the selection of a default character (radio or dropdown?) How to fetch the data and place it in the posts user info pane

    Read the article

  • LIBPCAP and WIRESHARK Capture on PPP

    - by user655629
    Hi, I have written a small bridge program using LIBPCAP API. I have installed Winpcap 3.1 Beta for support in order to capture from a PPP interface. What i do is, I capture from the PPP interface through my LIBPCAP program and send the traffic to another Ethernet interface in my computer. Then i connect this Ethernet Interface to another Ethernet Interface at another computer where i monitor it through Wireshark. So in short my PPP-Ethernet Bridge is on computer 1. And Another computer2 directly connected to computer1 on Ethernet monitors the incoming traffic from the bridge through wireshark. The problem i face is that when i capture PPP traffic through wireshark in computer1, i see reasonable delay between the packets. But when i use my LIBPCAP program to capture and relay traffic and check the traffic on computer 2 using Wireshark it gives jumps of 0.5seconds delay after some packets. This is quite unexplainable to me. I dont understand how wireshark PPP direct capture on computer 1 does not give delay and LIBPCAP program is giving delay. I have checked my bridge for Ethernet to Ethernet relaying and there is no delay like the one i am experiencing in case of PPP-Ethernet. a higher delay between packets is acceptable but such a BIG delay after a couple of packets is unacceptable. Please help if you can. Best Regards FIKA

    Read the article

  • What part of SMF is likely broken by a hard power down?

    - by David Mackintosh
    At one of my customer sites, the local guy shut down their local Solaris 10 x86 server, pulled the power inputs, moved it, and now it won’t start properly. It boots and then presents a prompt which lets you log in. This appears to be single user milestone (or equivalent). Digging into it, I think that SMF isn’t permitting the system to go multi-user. SMF was generating a ton of errors on autofs, after some fooling with it I got it to generate errors on inetd and nfs/client instead. This all tells me that the problem is in some SMF state file or database that needs to be fixed/deleted/recreated or something, but I don’t know what the actual issue is. By “generate errors”, I mean that every second I get a message on the console saying “Method or service exit timed out. Killing contract <#.” This makes interacting with the computer difficult. Running svcs –xv shows the service as “enabled”, in state “disabled”, reason “Start method is running”. Fooling with svcadm on the service does nothing, except confirm that the service is not in a Maintenance state. Logs in /lib/svc/log/$SERVICE just tell you that this loop has been happening once per second. Logs in /etc/svc/volatile/$SERVICE confirm that at boot the service is attempted to start, and immediately stopped, no further entries. Note that system-log isn’t starting because system-log depends on autofs so I have no syslog or dmesg. Googling all these terms ends up telling me how to debug/fix either autofs or nfs/client or inetd or rpc/gss (which was the dependency that SMF was using as an excuse to prevent nfs/client from “starting”, it was claiming that rpc/gss was “undefined” which is incorrect since this all used to work. I re-enabled it with inetadm, but inetd still won’t start properly). But I think that the problem is SMF in general, not the individual services. Doing a restore_repository to the “manifest_import” does nothing to improve, or even detectibly change, the situation. I didn’t use a boot backup because the last boot(s) were not useful. I have told the customer that since the valuable data directories are on a separate file system (which fsck’s as clean so it is intact) we could just re-install solaris 10 on the / partition. But that seems like an awfully windows-like solution to inflict on this problem. So. Any ideas what piece is broken and how I might fix it?

    Read the article

  • Recommended ADSL/ADSL2 router that supports PPTP VPN dial-out, 802.11n and gigabit ethernet?

    - by Throlkim
    I'm looking for a new router to provide a VPN tunnel for my home network. My plan is to pass all internet traffic over a PPTP VPN provided by the router, which should ensure that the connection stays alive and only passes traffic over that protocol. I'm normally quite a fan of Draytek routers, and their 2710n does seem to feature VPN dial-out but it lacks Gigabit ports (though I can make do with that if the VPN support is good enough). Has anyone got any suggestions or personal experience in a similar setup? I'm happy to consider anything that supports dd-wrt (as I believe that supports VPN-out, though I may be wrong). Bonus points for models available in the UK.

    Read the article

  • Macbook Pro 2010 Ethernet Jumbo Frame(9k MTU) Support?

    - by Troggy
    Has anyone been able to use jumbo frame support on their 2010 Macbook Pros? This is kind of negative news here, but I am seeing many reports that this is not available anymore due to Apple's choice of network card in the new machines. I cannot set my MTU speed over 1500 on my new 2010 MBP i7, but my old early 2008 MBP (Core2) has the 9000 MTU setting for use. Everything I have is setup to use jumbo frames and I thought apple kept that feature in their "pro" lineup. It sounds like the Mac Pro still has it. Did they decide to use a chipset that doesn't support it? I am trying to pinpoint some solid chipset numbers and the feature support. Maybe they just need to update the drivers? Is there some more official information about this feature? This might seem minor, but this is really frustrating if apple removed this feature from their pro laptop line. From what I have read so far, it sounds like I am not alone in my frustrations with this. http://discussions.info.apple.com/message.jspa?messageID=12258067 http://discussions.apple.com/thread.jspa?messageID=12130158 Anyone have any experience or further knowledge about this issue ... beyond typing my question into google and giving the top 5 results as answers? :)

    Read the article

  • How to run Android-x86 project's ISO in VirtualBox with ethernet?

    - by Shiki
    I managed to find a way just days ago, but I had to leave my other PC and now I have no clue how to get it working again. Basically you have to get the image, then install it in a VirtualBox guest. Now the problem is ... when you launch your VM, there is no internet connection. No with NAT or Bridged. Tried all the network cards too. Since internet connection is crucial for Android development, I have to get this thing working. (As I said, I managed to fix it once.) I'm using: - The 4.0 RC1 images from Android-x86 - VirtualBox - Eclipse 4.2 Juno with the latest Android ADT - Android SDK v18 - upgraded to 19 via the Package manager. Now I seen a lot of different builds on the net, about different Android builds for VirtualBox. I have checked Buildroid for example, but there is no network connection. I have imported the virtual machine just as the howto said. The extension package is also installed and it's up to date.

    Read the article

  • How can I join two simple home networks together using an ethernet cable?

    - by Ilia Jerebtsov
    I want to join two different home networks together like so: PC A1 PC A2 PC B1 PC B2 \ / \ / Gateway A <----- ethr. cable -----> Gateway B | | ADSL modem A ADSL modem B Both networks are of the basic residential type with identical configuration, with all PCs running Vista/7. The point is to temporarily join two apartments in a building for gaming and file sharing, and the holy grail would be: PCs on network A can access PCs on network B and vice-versa (file shares and gaming). Each network uses its own internet connection. Data between networks shouldn't take a trip through the internet (broadband upload speeds are severely capped) A network's internet access should continue working if the joining cable is disconnected with minimal configuration changes. How closely can this be achieved?

    Read the article

  • Raid 1 array won't assemble after power outage. How do I fix this ext4 mirror?

    - by Forkrul Assail
    Two ext4 drives on Raid 1 with mdadm won't reassemble after the power went out for an extended period (UPS drained). After turning the machine back on, mdadm said that the array was degraded, after which it took about 2 days for a full resync, which completed without problems. On trying to remount the array I get: mount: you must specify the filesystem type cat /etc/fstab lines relevant to setup: /dev/md127 /media/mediapool ext4 defaults 0 0 dmesg | tail (on trying to mount) says: [ 1050.818782] EXT3-fs (md127): error: can't find ext3 filesystem on dev md127. [ 1050.849214] EXT4-fs (md127): VFS: Can't find ext4 filesystem [ 1050.944781] FAT-fs (md127): invalid media value (0x00) [ 1050.944782] FAT-fs (md127): Can't find a valid FAT filesystem [ 1058.272787] EXT2-fs (md127): error: can't find an ext2 filesystem on dev md127. cat /proc/mdstat says: Personalities : [raid1] [linear] [multipath] [raid0] [raid6] [raid5] [raid4] [raid10] md127 : active (auto-read-only) raid1 sdj[2] sdi[0] 2930135360 blocks super 1.2 [2/2] [UU] unused devices: <none> fsck /dev/md127 says: fsck from util-linux 2.20.1 e2fsck 1.42 (29-Nov-2011) fsck.ext2: Superblock invalid, trying backup blocks... fsck.ext2: Bad magic number in super-block while trying to open /dev/md127 The superblock could not be read or does not describe a correct ext2 filesystem. If the device is valid and it really contains an ext2 filesystem (and not swap or ufs or something else), then the superblock is corrupt, and you might try running e2fsck with an alternate superblock: e2fsck -b 8193 <device> mdadm -E /dev/sdi gives me: /dev/sdi: Magic : a92b4efc Version : 1.2 Feature Map : 0x0 Array UUID : 37ac1824:eb8a21f6:bd5afd6d:96da6394 Name : sojourn:33 Creation Time : Sat Nov 10 10:43:52 2012 Raid Level : raid1 Raid Devices : 2 Avail Dev Size : 5860271016 (2794.40 GiB 3000.46 GB) Array Size : 2930135360 (2794.39 GiB 3000.46 GB) Used Dev Size : 5860270720 (2794.39 GiB 3000.46 GB) Data Offset : 262144 sectors Super Offset : 8 sectors State : clean Device UUID : 3e6e9a4f:6c07ab3d:22d47fce:13cecfd0 Update Time : Tue Nov 13 20:34:18 2012 Checksum : f7d10db9 - correct Events : 27 Device Role : Active device 0 Array State : AA ('A' == active, '.' == missing) boot@boot ~ $ sudo mdadm -E /dev/sdj /dev/sdj: Magic : a92b4efc Version : 1.2 Feature Map : 0x0 Array UUID : 37ac1824:eb8a21f6:bd5afd6d:96da6394 Name : sojourn:33 Creation Time : Sat Nov 10 10:43:52 2012 Raid Level : raid1 Raid Devices : 2 Avail Dev Size : 5860271016 (2794.40 GiB 3000.46 GB) Array Size : 2930135360 (2794.39 GiB 3000.46 GB) Used Dev Size : 5860270720 (2794.39 GiB 3000.46 GB) Data Offset : 262144 sectors Super Offset : 8 sectors State : clean Device UUID : 7fb84af4:e9295f7b:ede61f27:bec0cb57 Update Time : Tue Nov 13 20:34:18 2012 Checksum : b9d17fef - correct Events : 27 Device Role : Active device 1 Array State : AA ('A' == active, '.' == missing) machine@user ~ dmesg | tail [ 61.785866] init: alsa-restore main process (2736) terminated with status 99 [ 68.433548] eth0: no IPv6 routers present [ 534.142511] EXT4-fs (sdi): ext4_check_descriptors: Block bitmap for group 0 not in group (block 2838187772)! [ 534.142518] EXT4-fs (sdi): group descriptors corrupted! [ 546.418780] EXT2-fs (sdi): error: couldn't mount because of unsupported optional features (240) [ 549.654127] EXT3-fs (sdi): error: couldn't mount because of unsupported optional features (240) Since this is Raid 1 it was suggested that I try and mount or fsck the drives separately. After a long fsck on one drive, it ended with this as tail: Illegal double indirect block (2298566437) in inode 39717736. CLEARED. Illegal block #4231180 (2611866932) in inode 39717736. CLEARED. Error storing directory block information (inode=39717736, block=0, num=1092368): Memory allocation failed Recreate journal? yes Creating journal (32768 blocks): Done. *** journal has been re-created - filesystem is now ext3 again *** The drive however still doesn't want to mount: dmesg | tail [ 170.674659] md: export_rdev(sdc) [ 170.675152] md: export_rdev(sdc) [ 195.275288] md: export_rdev(sdc) [ 195.275876] md: export_rdev(sdc) [ 1338.540092] CE: hpet increased min_delta_ns to 30169 nsec [26125.734105] EXT4-fs (sdc): ext4_check_descriptors: Checksum for group 0 failed (43502!=37987) [26125.734115] EXT4-fs (sdc): group descriptors corrupted! [26182.325371] EXT3-fs (sdc): error: couldn't mount because of unsupported optional features (240) [27083.316519] EXT4-fs (sdc): ext4_check_descriptors: Checksum for group 0 failed (43502!=37987) [27083.316530] EXT4-fs (sdc): group descriptors corrupted! Please help me fix this. I never in my wildest nightmares thought a complete mirror would die this badly. Am I missing something? Suggestions on fixing this? Could someone explain why it would resync after the powerout, only to seemingly nuke the drive? Thanks for reading. Any help much appreciated. I've tried everything I can think of, including booting and filesystem checking with SystemRescue and Ubuntu liveboot discs.

    Read the article

  • How to route to a secondary interface on the same physical ethernet?

    - by sjose3612611
    INTERNET<->(wan)BRIDGED_DEVICE(lan)<->ETH_ROUTER<->LAN Problem: Need to access web server on BRIDGED_DEVICE's LAN from INTERNET via ROUTER (BRIDGED_DEVICE's web server cannot be accessed form INTERNET since it has no Public management IP). Cannot configure bridged device. It has a static IP on its LAN to which its web server binds. Attempt: Create a secondary/alias WAN Interface on ETH_ROUTER (e.g Primary: eth0.1 (for internet access) and Secondary: eth0.2 (for accessing web server on BRIDGED_DEVICE), (No VLANs). eth0.1 has a public IP; eth0.2 has a static private IP in the BRIDGED_DEVICE's subnet (e.g 10.0.X.Y). Iptables on ETH_ROUTER: Added a port forward (DNAT) from eth0.1 to eth0.2: iptables -t nat -I PREROUTING -i eth0.1 -p tcp --dport 80 -j DNAT --to-destination 10.0.X.Y iptables -t nat -I POSTROUTING -o eth0.2 -s 10.0.X.0/24 -j MASQUERADE Stateful firewall w/ overall drop policy on FORWARD chain, hence: iptables -I FORWARD -i eth0.1 -d 10.0.X.Y -p tcp --dport 80 -j ACCEPT Can ping from ETH_ROUTER to BRIDGED_DEVICE but unable to reach the web server from Internet. I see packet cont increasing for the DNAT rule but not sure where it disappears in the ETH_ROUTER after that. ETH_ROUTER is the only device that can be configured to achieve this. If familiar with this scenario, please suggest what I may be missing or doing wrong here or suggest techniques to debug?

    Read the article

< Previous Page | 58 59 60 61 62 63 64 65 66 67 68 69  | Next Page >