Search Results

Search found 14837 results on 594 pages for 'duplicate ip'.

Page 64/594 | < Previous Page | 60 61 62 63 64 65 66 67 68 69 70 71  | Next Page >

  • Fixing copy/paste for Remote Desktop Connection sessions [duplicate]

    - by netadictos
    Possible Duplicate: Can't copy and paste in Remote Desktop Connection session Recently I have been working with Remote Desktop Connection. I use it to access a virtual machine implemented through Hyper-V. I have had many problems with the simple operation of cut-and-paste from my machine to the virtual one. The link between my clipboard and the remote clipboard is often broken. It is usual that this happens, when I copy/cut in the remote machine and then copy in my computer and then paste in the remote machine, How do I fix this?

    Read the article

  • Duplicate Name Exists error from virtual PC with NAT network configuration

    - by Phred
    Whenever I change the network configuration to NAT for a virtual machine running under Virtual PC 2007, I get "A duplicate name exists on the network." error. There is no other machine on my network with this name and running the VM in any other network configuration doesn't cause this error. This seems to be a common problem with Virtual PC 2007 based on a google search but no-one seems to have a solution to it. So far, I've discovered that turning off NETBIOS over TCP causes the problem to go away but I need to join this VM to a domain and you can't do that if NETBIOS over TCP is turned off.

    Read the article

  • Dropping duplicate|redundant Unique Constraint from FILESTREAM table

    - by electricsk8
    I have a table with a FILESTREAM column, and it has two unique constraints specified for the same FILESTREAM column, ie: ALTER TABLE [dbo].[TableName] ADD CONSTRAINT [UQ_TableName_33C4988760FC61CA] UNIQUE NONCLUSTERED ([GUID_Column]); GO ALTER TABLE [dbo].[TableName] ADD CONSTRAINT [UQ_TableName_33C49887145C0A3F] UNIQUE NONCLUSTERED ([GUID_Column]); GO I'd like to drop one of the unique constraints, as they are duplicates. However, when I try and drop one of the two duplicate constraints, I receive the following error. "A table with FILESTREAM column(s) must have a non-NULL unique ROWGUID column." Anyone know how to remove one of the two constraints?

    Read the article

  • Can I set Windows default second-monitor behaviour to "Extend these displays"?

    - by MT_Head
    I travel to multiple offices (and multiple desks in those offices), and whenever possible I plug an external monitor into my laptop. Whenever I plug in a monitor I haven't used before, Windows defaults to "Duplicate these displays" - which messes up the arrangement of icons on my desktop if the external monitor is a different shape from my laptop's monitor. I then select "Extend these displays", and my laptop screen returns to its original shape - but my icons don't go back to their original arrangement. Grrrrr. Fast-forward a few days or weeks; I've got my icons arranged so I can find stuff again - then I go to a new office and it starts all over again. I'm tired of this. Is it possible to make "Extend these displays" the default behavior? I'm using Windows 8 x64 Home Premium, but I had the same complaint under Windows 7 x64 Ultimate. (Prior to that, I hadn't discovered the joy of dual displays. Ah, the time I wasted...)

    Read the article

  • De-duplicate Firefox bookmarks

    - by Zoredache
    What methods exist to de-duplicate Firefox bookmarks. As I search Google I find that there previously was a plugin called CheckPlaces, but that no longer seems to exist. Another popular suggestion seems to be AM-DeadLink, which I tried, but it completely trashed my bookmarks. (Fortunately I had a backup first, and yes I had closed Firefox first as instructed). I was trying to move all my youtube.com bookmarks into a folder. I tried doing a search, and then dragging the bookmarks into the folder. Apparently this creates a copy, instead of moving them as I expected. So now I have 3 of everything since I had tried a couple times.

    Read the article

  • A Duplicate name exists on the network

    - by Adam
    Recently we changed out office IT structure from having a dedicated server to be the DC, a dedicated server for the exchange etc... (Each running Windows Server 2003 R2) Now we have a single server running Windows SBS 2008 and created a new domain (with a different domain name) We then changed every PC so it connected to the new domain and renamed every PC with a new naming structure. After I had done this, we were getting several PCs that would get the following message just before the login screen (Alt+Ctrl+Del Screen) A Duplicate name exists on the network I have checked the ADUC and have removed the trouble PCs from the list and renamed each PC and changed the SID before connecting back onto the domain but still getting this message. I have tried everything that i can think of but still getting the problem. Any help would be greatly appreticated.

    Read the article

  • Find RARs with duplicate content

    - by Scott McClenning
    I need a utility to find RAR files that contain duplicate data (i.e. files within the RAR that hash the same, but could have different names). I can open the RARs and see the CRCs are the same, but I was hoping for a more automated process that would work in bulk (hundreds of files). Hashing the overall RAR won't help because the file contained within could have different names, or the archive could be compressed at different levels. If needed, a utility that would extract the contents of the RARs and then compare would work, but is not preferred. I would prefer a free utility for Windows, but a pay utility or a utility for Linux would be acceptable.

    Read the article

  • In UDP, destination

    - by ert
    In UDP, destination IP and destination port number are used to demultiplex the packets, but in TCP destination IP, source IP, destination port number and source port numbers (4-tuple) all needed to distinguish between the connections why reasoning for this usage.

    Read the article

  • Router Alert options on IGMPv2 packets

    - by Scakko
    I'm trying to forge an IGMPv2 Membership Request packet and send it on a RAW socket. The RFC 3376 states: IGMP messages are encapsulated in IPv4 datagrams, with an IP protocol number of 2. Every IGMP message described in this document is sent with an IP Time-to-Live of 1, IP Precedence of Internetwork Control (e.g., Type of Service 0xc0), and carries an IP Router Alert option [RFC-2113] in its IP header So the IP_ROUTER_ALERT flag must be set. I'm trying to forge the strict necessary of the packet (e.g. only the IGMP header & payload), so i'm using the setsockopt to edit the IP options. some useful variables: #define C_IP_MULTICAST_TTL 1 #define C_IP_ROUTER_ALERT 1 int sockfd = 0; int ecsockopt = 0; int bytes_num = 0; int ip_multicast_ttl = C_IP_MULTICAST_TTL; int ip_router_alert = C_IP_ROUTER_ALERT; Here's how I open the RAW socket: sock_domain = AF_INET; sock_type = SOCK_RAW; sock_proto = IPPROTO_IGMP; if ((ecsockopt = socket(sock_domain,sock_type,sock_proto)) < 0) { printf("Error %d: Can't open socket.\n", errno); return 1; } else { printf("** Socket opened.\n"); } sockfd = ecsockopt; Then I set the TTL and Router Alert option: // Set the sent packets TTL if((ecsockopt = setsockopt(sockfd, IPPROTO_IP, IP_MULTICAST_TTL, &ip_multicast_ttl, sizeof(ip_multicast_ttl))) < 0) { printf("Error %d: Can't set TTL.\n", ecsockopt); return 1; } else { printf("** TTL set.\n"); } // Set the Router Alert if((ecsockopt = setsockopt(sockfd, IPPROTO_IP, IP_ROUTER_ALERT, &ip_router_alert, sizeof(ip_router_alert))) < 0) { printf("Error %d: Can't set Router Alert.\n", ecsockopt); return 1; } else { printf("** Router Alert set.\n"); } The setsockopt of IP_ROUTER_ALERT returns 0. After forging the packet, i send it with sendto in this way: // Send the packet if((bytes_num = sendto(sockfd, packet, packet_size, 0, (struct sockaddr*) &mgroup1_addr, sizeof(mgroup1_addr))) < 0) { printf("Error %d: Can't send Membership report message.\n", bytes_num); return 1; } else { printf("** Membership report message sent. (bytes=%d)\n",bytes_num); } The packet is sent, but the IP_ROUTER_ALERT option (checked with wireshark) is missing. Am i doing something wrong? is there some other methods to set the IP_ROUTER_ALERT option? Thanks in advance.

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • pfsense single MAC is listed with several IP's in ARP table

    - by Tillebeck
    I have this problem: arp table filling up But I am quite sure that I cannot blame Kaspersky. Scenarie: a user plugs his computer in. He waits and waits but are getting no IP by DHCP. Then he is told there is an IP conflict... He end up assigning himself a static IP to access the net In the ARP table of the router I see: 192.168.24.144 00:16:41:42:3c:9e Lenovo LAN 192.168.24.145 00:16:41:42:3c:9e Lenovo LAN 192.168.24.181 00:16:41:42:3c:9e Lenovo LAN 192.168.24.150 00:16:41:42:3c:9e Lenovo LAN 192.168.24.151 00:16:41:42:3c:9e Lenovo LAN 192.168.24.152 00:16:41:42:3c:9e Lenovo LAN 192.168.24.156 00:16:41:42:3c:9e Lenovo LAN 192.168.24.157 00:16:41:42:3c:9e Lenovo LAN 192.168.24.159 00:16:41:42:3c:9e Lenovo LAN 192.168.24.160 00:16:41:42:3c:9e Lenovo LAN 192.168.24.130 00:16:41:42:3c:9e Lenovo LAN 192.168.24.132 00:16:41:42:3c:9e Lenovo LAN 192.168.24.164 00:16:41:42:3c:9e Lenovo LAN 192.168.24.137 00:16:41:42:3c:9e Lenovo LAN 192.168.24.140 00:16:41:42:3c:9e Lenovo LAN 192.168.24.206 00:16:41:42:3c:9e Lenovo LAN The last .206 is the static address he gave himself. Several users descripe the exact same problem. It started after removing some filters in the switches, så all users are on a LAN and can see each other. Before, when filters blocked access to each others comptuers no one reported this kind of behavior. Any idéeas?

    Read the article

  • DD-WRT router causing IP address conflicts across network

    - by r.tanner.f
    My DD-WRT router has lost its mind! I just set up two DD-WRT routers, one as a WAP (working fine) and one in Client Bridge (routed) mode (the problem). Not long after setup I started seeing IP address conflicts on other machines. The event log always points the finger at my Client Bridge router's MAC address. Neighbour table overflow The log on my router is flooded with Neighbour table overflow errors. These start a minute or two after boot. The network is rather large, with +200 IP addresses being used in this subnet. The other router shows no such errors. Mass ARP requests from 1.1.1.1 I'm also seeing constant ARP requests (with the problem router's MAC address) from 1.1.1.1. Seems like it's bugging everything on the network for its MAC address and then promptly forgetting it (or never receiving a response). Configuration: Model: Buffalo N600 Firmware: DD-WRT v24SP2-MULTI (03/21/11) Wireless Mode: Client Bridge (routed) I'm not sure what configuration details are relevant and I'd rather not have comments flooded, so just ping me in this chat if you want to know something. Why is my router stealing IP addresses and how can I stop it?

    Read the article

  • Windows Server 2008 R2 DNS - One IP, multiple servers

    - by Blu Dragon
    I need opinions and examples on how to best to accomplish the setup I am looking for. I have a public-facing AD domain server with one public IP address. I have setup an external zone for example.com and I successfully have my own name servers pointing to it at ns0.example.com and ns1.example.com. I also have an internal zone for my private network at home.example.com. I am behind a router with the domain server in the DMZ. I want dev.example.com to be accessible from the outside world over https and to point to internal IP address 192.168.1.78. Likewise, I want www.example.com to be accessible from the outside world and point to internal IP address 192.168.1.79. Both dev and www servers are CentOS 5.6 VMs running inside of Hyper-V on the domain server (bad idea I know but I am limited on hardware atm). What is best way to achieve this? From what I have read and researched on Google, I may need to setup a reverse proxy but I am not sure how well that will work with SSL.

    Read the article

  • VMWare Guest Info - Wrong IP Returned

    - by Jon Bailey
    We're running a VDI environment with vSphere 4.0 and Oracle VDI 3.2.2 and are having a bit of a problem with users that connect to an IPSec VPN from within their VM. For some reason, once connected to the VPN, the VMWare API returns GuestInfo.ipAddress as the VPN IP rather than the primary IP of the only NIC on the system. The IP address shown in net[0].ipAddress is the correct address and is what vSphere client is reporting. Is there any way to get VMWare tools to report the net[0].ipAddress as GuestInfo.ipAddress? Below is sample output from the guestinfo.pl script. 172.16.1.2 is the example "bad" VPN address that our VDI software is seeing. VMXFLEX01 guestFamily: windowsGuest VMXFLEX01 guestFullName: Microsoft Windows XP Professional (32-bit) VMXFLEX01 guestId: winXPProGuest VMXFLEX01 guestState: running VMXFLEX01 hostName: VMXFLEX01 VMXFLEX01 ipAddress: 172.16.1.2 VMXFLEX01 toolsStatus: VMware Tools is running and the version is current. VMXFLEX01 toolsVersion: 8194 VMXFLEX01 Screen - Height: 600 VMXFLEX01 Screen - Width: 800 VMXFLEX01 Disk[0]: Capacity 42935926784 VMXFLEX01 Disk[0]: Path : C:\ VMXFLEX01 Disk[0]: freespace : 33272619008 VMXFLEX01 net[0] - connected : 1 VMXFLEX01 net[0] - deviceConfigId : 4000 VMXFLEX01 net[0] - macAddress : 00:50:56:95:1f:c9 VMXFLEX01 net[0] - network : VM Network VMXFLEX01 net[0] - ipAddress : 10.0.0.2

    Read the article

  • How to point a subdomain to local server with dynamic IP

    - by jlego
    I see there are many related questions to this one, however the answers given seem to be a little vague for a novice like me. I've got a dedicated LAMP stack running Fedora 16 locally on my home network. Everything works fine internally. I can access the Apache server from other machines on the network using the internal IP in a browser. I'm using the stack for a local file server as well as a development environment for websites. There are a couple of reasons why I would like the development sites hosted on the machine to be available publicly. 1.) I use a CMS that has paid add-ons which allows you to assign the paid license to a domain. I can't develop with paid add-ons on the closed dev server. 2.) I would occasionally like for clients to be able to view the site dev at late stages before it goes live. I have a domain (foo.com, and I want to point a *sub*domain (dev.foo.com) to the local server. I know this is best accomplished with a Static IP, however my IP from my ISP is Dynamic and I don't think there is any way to change that. From what I have read, services like ZoneEdit & DynDNS are supposed to be able to accomplish this, but I have tried both and found it very confusing. Also the server is behind a router and I have also read that you need to set up DDNS(?) in your router, that many routers have presets for these services, and I've found that DynDNS is the only one my router seems to support.

    Read the article

  • RRAS with DHCP when the IP pool is on a different subnet

    - by John B
    I run a small business network and the last couple of days I have been setting up some equipment to add VPN capabilities to our network. I've got the following set up: Windows 2008 R2 with RRAS - 172.22.200.50 Cisco RV082 router - 172.22.100.1 / 172.22.200.1 The Cisco router only support DHCP on a single class C network; 172.22.100.0/24. On the Cisco router I have set up an additional subnet; 172.22.200.0/24. The DHCP range is 172.22.100.200-254 When a PPTP connection comes in to the router, it is forwarded to my RRAS at 172.22.200.50. If I configure RRAS to assign IPs from a static pool on the 172.22.200.0/24 subnet everything works fine except the DNS suffix / search domain. However, if I set RRAS to use DHCP I am no longer able to contact any devices on the network. The IP I receive is on a different subnet (172.22.100.0/24). Is it possible to still use DHCP as the method of ip assignment in RRAS, even when the IP adresses assigned are in a different subnet? If yes, what piece of configuration am I missing to fix the VPN connection issues mentioned in the paragraph above. The reason I want RRAS with DHCP to work is because from what I have understood, this is the "only" way to hand out a DNS suffix to VPN clients. Any help on this matter is greatly appreciated!

    Read the article

  • iptables, blocking large numbers of IP Addresses

    - by Twirrim
    I'm looking to block IP addresses in a relatively automated fashion if they look to be 'screen scraping' content from websites that we host. In the past this was achieved by some ingenious perl scripts and OpenBSD's pf. pf is great in that you can provide it nice tables of IP addresses and it will efficiently handle blocking based on them. However for various reasons (before my time) they made the decision to switch to CentOS. iptables doesn't natively provide the ability to block large numbers of addresses (I'm told it wasn't unusual to be blocking 5000+), and I'm a bit cautious over adding that many rules into an iptable. ipt_recent would be awesome for doing this, plus it provides a lot of flexibility for just severely slowing down access, but there is a bug in the CentOS kernel that is stopping me from using it (reported, but awaiting fix). Using ipset would entail compiling a more up-to-date version of iptables than comes with CentOS which whilst I'm perfectly capable of doing it, I'd rather not do from a patching, security and consistency perspective. Other than those two it looks like nfblock is a reasonable alternative. Is anyone aware of other ways of achieving this? Are my concerns about several thousand IP addresses in iptables as individual rules unfounded?

    Read the article

  • certificate working on IP but not on URL

    - by Stephan
    I asked this question on stackoverflow, and I've been suggested to repost it here. I have a problem accessing my site (on https) with IEMobile 9 (WP 7.5). It says it's got problem with the certificate, as if it wasn't valid. Everything works on any other browser or platform I tested (android (several phones and a galaxy tab with stock browser, firefox, opera, dolphin), iOS (iphone and ipad with safari and chrome), an old nokia with symbian, windows 7, linux and mac). To try to solve this I saved the certificate (.cer) on the server and accessed it from the phone browser. It always complained except when I accessed it through the server IP (192.168.xx.xx). At that point it (said it) installed correctly the certificate. If then I try to access the index.html still using the IP all works fine and it doesn't complain about the certificate. If, though, I try to access the index using the actual URL (blah.myblah.com), it complains again about the certificate, as if it wasn't installed! It isn't a problem of DNS, cause that's up and serving the right ip, and the phone is correctly setup to use it. The certificate is signed by geotrust/rapidssl for *.myblah.com.

    Read the article

  • Forward real IP through Haproxy => Nginx => Unicorn

    - by Hendrik
    How do I forward the real visitors ip adress to Unicorn? The current setup is: Haproxy => Nginx => Unicorn How can I forward the real IP address from Haproxy, to Nginx, to Unicorn? Currently it is always only 127.0.0.1 I read that the X headers are going to be depreceated. http://tools.ietf.org/html/rfc6648 - how will this impact us? Haproxy Config: # haproxy config defaults log global mode http option httplog option dontlognull option httpclose retries 3 option redispatch maxconn 2000 contimeout 5000 clitimeout 50000 srvtimeout 50000 # Rails Backend backend deployer-production reqrep ^([^\ ]*)\ /api/(.*) \1\ /\2 balance roundrobin server deployer-production localhost:9000 check Nginx Config: upstream unicorn-production { server unix:/tmp/unicorn.ordify-backend-production.sock fail_timeout=0; } server { listen 9000 default; server_name manager.ordify.localhost; root /home/deployer/apps/ordify-backend-production/current/public; access_log /var/log/nginx/ordify-backend-production_access.log; rewrite_log on; try_files $uri/index.html $uri @unicorn; location @unicorn { proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; proxy_set_header Host $http_host; proxy_set_header X-Real-IP $remote_addr; proxy_redirect off; proxy_pass http://unicorn-production; proxy_connect_timeout 90; proxy_send_timeout 90; proxy_read_timeout 90; } error_page 500 502 503 504 /500.html; client_max_body_size 4G; keepalive_timeout 10; }

    Read the article

  • IP Blacklists and suspicious inbound and outbound traffic

    - by Pantelis Sopasakis
    I administer a web server and recently we had our IP banned (!) from our host after they received a notification e-mail for abuse. In particular our server is allegedly involved in spam attacks over HTTP. The content of the abuse report email we received was not much informative - for example the IP addresses our server is supposed to have attacked against are not included - so I started a wireshark session checking for suspicious traffic over TCP/HTTP while trying to locate possible security holes on the system. (Let me note that the machine runs a Debian OS). Here is an example of such a request... Source: 89.74.188.233 Destination: 12.34.56.78 // my ip Protocol: HTTP Info: GET 'http://www.media.apniworld.com/image.php?type=hv' HTTP/1.0 I manually blacklisted this host (as well as some other ones) blocking them with iptables, but I can't keep on doing manually all day long... I'm looking for an automated way to block such IPs based on: Statistical analysis, pattern recognition or other AI-based analysis (Though, I'm reluctant to trust such a solution, if exists) Public blacklists Using DNSBL I actually found out that 89.74.188.233 is blacklisted. However other IPs which are strongly suspicious like 93.199.112.126 (i.e. http://www.pornstarnetwork.com/account/signin), unfortunately were not blacklisted! What I would like to do is to automatically connect my firewall with DNSBL (or some other blacklist database) and block all traffic towards blacklisted IPs or somehow have my local blacklist automatically updated.

    Read the article

  • Cisco BVI: Claiming IP addresses

    - by cjavapro
    I would like to make sure I understand this correctly. Given a Cisco ISO router that is set up with a BVI (a variation of a bridge route).. and the following layout "ISP router" \ "Network switch" # nothing special here. | \ | \ | \ | \ "Router 1 with NAT" "Router 2 with BVI" If I understand correctly.. the outside of a BVI will only respond to IP addresses that have already been claimed on the inside of the BVI... example subnet is 123.123.123.??? and servers inside the BVI on 123.123.123.10 and 123.123.123.11, and the NAT router is holding a public IP address of 123.123.123.50. If a connection comes in to 123.123.123.10 it will be received by router 2 but if it is received on 123.123.123.50, it will be received by router 1 and not received by router 2. and if a connection comes in to 123.123.123.90 (does not exist) it will not be received by either router. Am I correct? Is it true that the BVI router will not even receive packets to IP addresses that it does not see as existing on the inside?

    Read the article

  • Host ::1 resolves to remote IP

    - by thebuckst0p
    /etc/hosts files usually have this line, ::1 localhost. I thought ::1 was the equivalent of 127.0.0.1/localhost, and from my reading it seems to be the IPv6 version. So I was using it in Apache for firewalling, "Allow from ::1" and it only allowed local. Then suddenly that stopped working, so I pinged ::1 and got a remote IP address. I tracerouted it and it went through my ISP, through some Microsoft server, then another half dozen steps of asterisks... I'm not sure why this would be (the remote IP), but it doesn't seem good. I grep'd my hard drive for the remote IP and it doesn't appear anywhere. Is this some indicator that I'm being hacked, or normal behavior? Maybe my IPv6 settings are wrong? (This is a brand new MacBookPro with Snow Leopard.) Any ideas about this would be great - what is ::1 supposed to be, why would it be remote, should I be worried, how do I get it back to localhost? Thank you!

    Read the article

  • Windows 2003 DC to Windows 2008 R2 DC with same name and same IP

    - by TheCleaner
    Environment = Windows 2003 native domain with 8 DCs I've got an old domain controller that is running 2003, CA Enterprise role, DHCP, DNS, a few GPO scripts that point to shares on it, and some other minor functions. All our servers point to it as their primary DNS, and there's lots of references to its IP or name throughout the domain at this point (8+ years later). I really don't feel like manually changing all of this, it would be a pretty massive undertaking. I want to follow this guide: http://msmvps.com/blogs/acefekay/archive/2010/10/09/remove-an-old-dc-and-introduce-a-new-dc-with-the-same-name-and-ip-address.aspx to hopefully end up with basically an "in-place upgrade" so to say. I considered just doing a P2V of the box, but we don't really want to keep it around running 2003 to be honest. I also considered using a CNAME and adding a 2nd IP (the old one) but again, it seemed like it would be cleaner using the attached link. My actual question: Any gotchas or big caution signs when doing what the link suggests? Anyone gone down this road and have advice on how to proceed?

    Read the article

  • Xen Bridge only working when IP Assigned

    - by m.sr
    Hey! Just had an (in my sense) obscure situation. I have a Xen Server with bridged networking. Everything works fine since month. A while ago i configuresd a second bridge. only some DomUs get an channel on this bridge - my Dom0 doesn't need to / should'nt use this bridge. So just 5 minutes ago while rebooting the xen host (because of an other problem with the UPS) i decided to removed the fixed ip from the the interface of the Dom0 which belongs to the second bridge. So after reboot i noticed that none of the interfaces on the second bridge is available. I couldn't find a problem. Everything was just like before the reboot, except the interface of the Dom0 had no IP address. After a while i tried to give the DomO interface of this bridge an IP again and ... BOOM ... everything is up and running again! WTF? Why is it important to have the interface of a bridge configured in the Dom0? Even when confiugured 'wrong' (complitely different netowkr settings as the network really hanging on the bridge) everythjing works fine ... I don't get it. Could please someone explain? Tnaks a lot!

    Read the article

< Previous Page | 60 61 62 63 64 65 66 67 68 69 70 71  | Next Page >