Search Results

Search found 56327 results on 2254 pages for 'console application'.

Page 66/2254 | < Previous Page | 62 63 64 65 66 67 68 69 70 71 72 73  | Next Page >

  • Serial connection over a single USB cable (Windows to linux, or linux to linux)

    - by andyortlieb
    I'm helping out with a project for an embedded device that only has USB and no serial. This device is running Linux. These days, when we need to connect to a serial port on a device we typically use a USB to serial adapter (on something like a phone system or a load balancing device, etc). I would like to know if it is possible to have the host device behave as though it were a serial adapter, thus removing the need for one. Given the nature of USB, is this approach even necessary? To recap, I would like to be able to connect a single A-to-A USB cable from my workstation (be it windows or linux) to this device, for the purpose of administration (especially initial setup), using minicom, putty or hyperterminal. Thanks

    Read the article

  • Which are the non-x text editors in Powershell?

    - by Andrei T. Ursan
    Are there some editors like emacs, vi/vim, specifically for power shell, if so which are the best? I will have to do some work on windows and I need some unix productivity - which means for me shell + text editor with syntax highlighting (for python, java, c, c++), so which are my options? Edit: I'm looking for an alternative at vim or other unix editors, and cygwin is not an option. I just want from the command line to say texteditor_name file1, modify it, save it etc, and all of these to happen inside the terminal, not in another interface etc.

    Read the article

  • How can I login to Ubuntu using a USB serial port?

    - by marc
    How can enable remote terminal login into Ubuntu 9.10 using a USB serial port? I created device /dev/ttyUSB0 and i want to allow logins using Hyper-Terminal. I found some resources but they are related to real hardware rs232 ports. I can't find any information about USB converter. So far I have established connection between that USB-serial port and my laptop. I can send text to the port (cp sometext.txt /dev/ttyUSB0) and read it using hyperterminal. What do I need to do to enable logins on this port?

    Read the article

  • Powershell not displyaing Unix colors

    - by Paul Nathan
    I use various Linux programs on my machine; some of them have colorized output. However, Windows Powershell does not support Linux colors; it get a message like so ?[0m31m(which is the color control code), and renders that instead of the color. Is there a way around this?

    Read the article

  • Application Event Log keeps getting corrupted

    - by yakatz
    I recently asked about repairing a corrupt event log, because it seemed to be a one-off event. The event log has since exhibited the same behavior 3 times. We have been trying to find patterns, but so far we have found nothing. The server runs several ASP.NET applications and three scheduled tasks written in .NET. The last modified date of the event log once happened to be the same time as one of the scheduled tasks, but the others have not been. Any suggestions of where to look next or a way we can get any information out of a corrupt evtx file? The server is running critical e-commerce applications, so we want to keep the number of restarts required to a minimum. Edit: I ran DUMPEL and got very strange results. 1/9/2012 4:14:05 PM 1 100 1000 Application Error N/A SERVERNAME Faulting application name: w3wp.exe, version: 7.5.7601.17514, time stamp: 0x4ce7a5f8 Faulting module name: ntdll.dll, version: 6.1.7601.17514, time stamp: 0x4ce7ba58 Exception code: 0xc0000374 Fault offset: 0x000ce653 Faulting process id: 0x1070 Faulting application start time: 0x01cccf1386d30991 Faulting application path: C:\Windows\SysWOW64\inetsrv\w3wp.exe Faulting module path: C:\Windows\SysWOW64\ntdll.dll Report Id: dbf4f691-3b06-11e1-9025-005056a602e6 1/9/2012 4:14:07 PM 4 0 1001 Windows Error Reporting N/A SERVERNAME Fault bucket , type 0 Event Name: APPCRASH Response: Not available Cab Id: 0 Problem signature: P1: w3wp.exe P2: 7.5.7601.17514 P3: 4ce7a5f8 P4: StackHash_79d9 P5: 6.1.7601.17514 P6: 4ce7ba58 P7: c0000374 P8: 000ce653 P9: P10: Attached files: C:\Windows\Temp\WER975.tmp.appcompat.txt C:\Windows\Temp\WERA03.tmp.WERInternalMetadata.xml C:\Windows\Temp\WERA13.tmp.hdmp C:\Windows\Temp\WERD21.tmp.mdmp These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_w3wp.exe_cd7d09dfc84119d82a2ac6a789038bd5661acfb_cab_128f0e67 Analysis symbol: Rechecking for solution: 0 Report Id: dbf4f691-3b06-11e1-9025-005056a602e6 Report Status: 4 1/9/2012 4:14:07 PM 4 0 1001 Windows Error Reporting N/A SERVERNAME Fault bucket , type 0 Event Name: APPCRASH Response: Not available Cab Id: 0 Problem signature: P1: w3wp.exe P2: 7.5.7601.17514 P3: 4ce7a5f8 P4: StackHash_79d9 P5: 6.1.7601.17514 P6: 4ce7ba58 P7: c0000374 P8: 000ce653 P9: P10: Attached files: C:\Windows\Temp\WER975.tmp.appcompat.txt C:\Windows\Temp\WERA03.tmp.WERInternalMetadata.xml C:\Windows\Temp\WERA13.tmp.hdmp C:\Windows\Temp\WERD21.tmp.mdmp These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_w3wp.exe_cd7d09dfc84119d82a2ac6a789038bd5661acfb_cab_128f0e67 Analysis symbol: Rechecking for solution: 0 Report Id: dbf4f691-3b06-11e1-9025-005056a602e6 Report Status: 0 1/9/2012 4:14:12 PM 1 100 1000 Application Error N/A SERVERNAME Faulting application name: w3wp.exe, version: 7.5.7601.17514, time stamp: 0x4ce7a5f8 Faulting module name: ntdll.dll, version: 6.1.7601.17514, time stamp: 0x4ce7ba58 Exception code: 0xc0000374 Fault offset: 0x000ce653 Faulting process id: 0x16ac Faulting application start time: 0x01cccf139f475c0c Faulting application path: C:\Windows\SysWOW64\inetsrv\w3wp.exe Faulting module path: C:\Windows\SysWOW64\ntdll.dll Report Id: e03bae70-3b06-11e1-9025-005056a602e6 1/9/2012 4:14:16 PM 4 0 1001 Windows Error Reporting N/A SERVERNAME Fault bucket , type 0 Event Name: APPCRASH Response: Not available Cab Id: 0 Problem signature: P1: w3wp.exe P2: 7.5.7601.17514 P3: 4ce7a5f8 P4: StackHash_9c6c P5: 6.1.7601.17514 P6: 4ce7ba58 P7: c0000374 P8: 000ce653 P9: P10: Attached files: C:\Windows\Temp\WER2579.tmp.appcompat.txt C:\Windows\Temp\WER25F7.tmp.WERInternalMetadata.xml C:\Windows\Temp\WER25F8.tmp.hdmp C:\Windows\Temp\WER28F6.tmp.mdmp These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_w3wp.exe_c49a67649524ad11b64bbf809211bc5ba742a3d6_cab_0b63321b Analysis symbol: Rechecking for solution: 0 Report Id: e03bae70-3b06-11e1-9025-005056a602e6 Report Status: 4 1/9/2012 4:14:16 PM 4 0 1001 Windows Error Reporting N/A SERVERNAME Fault bucket , type 0 Event Name: APPCRASH Response: Not available Cab Id: 0 Problem signature: P1: w3wp.exe P2: 7.5.7601.17514 P3: 4ce7a5f8 P4: StackHash_9c6c P5: 6.1.7601.17514 P6: 4ce7ba58 P7: c0000374 P8: 000ce653 P9: P10: Attached files: C:\Windows\Temp\WER2579.tmp.appcompat.txt C:\Windows\Temp\WER25F7.tmp.WERInternalMetadata.xml C:\Windows\Temp\WER25F8.tmp.hdmp C:\Windows\Temp\WER28F6.tmp.mdmp These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_w3wp.exe_c49a67649524ad11b64bbf809211bc5ba742a3d6_cab_0b63321b Analysis symbol: Rechecking for solution: 0 Report Id: e03bae70-3b06-11e1-9025-005056a602e6 Report Status: 0 1/9/2012 4:14:21 PM 1 100 1000 Application Error N/A SERVERNAME Faulting application name: w3wp.exe, version: 7.5.7601.17514, time stamp: 0x4ce7a5f8 Faulting module name: ntdll.dll, version: 6.1.7601.17514, time stamp: 0x4ce7ba58 Exception code: 0xc0000374 Fault offset: 0x000ce653 Faulting process id: 0x17f8 Faulting application start time: 0x01cccf13a4ba5126 Faulting application path: C:\Windows\SysWOW64\inetsrv\w3wp.exe Faulting module path: C:\Windows\SysWOW64\ntdll.dll Report Id: e57a0a85-3b06-11e1-9025-005056a602e6 1/9/2012 4:14:21 PM 4 0 1001 Windows Error Reporting N/A SERVERNAME Fault bucket , type 0 Event Name: APPCRASH Response: Not available Cab Id: 0 Problem signature: P1: w3wp.exe P2: 7.5.7601.17514 P3: 4ce7a5f8 P4: StackHash_9c6c P5: 6.1.7601.17514 P6: 4ce7ba58 P7: c0000374 P8: 000ce653 P9: P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_w3wp.exe_c49a67649524ad11b64bbf809211bc5ba742a3d6_1cfb4872 Analysis symbol: Rechecking for solution: 0 Report Id: e57a0a85-3b06-11e1-9025-005056a602e6 Report Status: 4 1/9/2012 4:14:21 PM 4 0 1001 Windows Error Reporting N/A SERVERNAME Fault bucket , type 0 Event Name: APPCRASH Response: Not available Cab Id: 0 Problem signature: P1: w3wp.exe P2: 7.5.7601.17514 P3: 4ce7a5f8 P4: StackHash_9c6c P5: 6.1.7601.17514 P6: 4ce7ba58 P7: c0000374 P8: 000ce653 P9: P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_w3wp.exe_c49a67649524ad11b64bbf809211bc5ba742a3d6_1cfb4872 Analysis symbol: Rechecking for solution: 0 Report Id: e57a0a85-3b06-11e1-9025-005056a602e6 Report Status: 0 None of the files referenced actually exist (not even in WER ReportArchive). These should not be the only events mentioned. The log file has been cleared twice since January 9, so those events should not even be listed at all.

    Read the article

  • Capturing XEN Dom0 logs on Debian lenny ?

    - by Xavier
    I have a Dell server with Xen 3.2 (from Debian Lenny) running a Debian Lenny dom0. Since I am facing unexpected reboot without any clue in the debian logs, I would like to capture the Xen dom0 logs. Did anybody achieve this and how ? I tried to use the Dell serial port redirection without success.

    Read the article

  • mysql command line not working

    - by Sandeepan Nath
    I have mysql running in my fedora system. I have xampp setup on the system and php projects present in the webspace are working fine. PhpMyAdmin is working fine. echoing phpinfo() in a PHP script also shows mysql enabled. But running mysql connect command mysql -u[username] -p[password] Gives this - bash: mysql: command not found How do I fix that? Any pointers? I guess I need to do some pointing (define some path in some file) so that my system knows that mysql is installed. What exactly do I have to do? Additional Details This system was someone else's and he is not available here. May be PHP/Mysql was setup already in the system. I just freshly extracted xampp for linux into /opt/lampp/ and have put all the above mentioned things (PHP projects and PhpMyAdmin) there. After doing that I had a socket problem (PhpMyAdmin was not working and showing this)- #2002 - The server is not responding (or the local MySQL server's socket is not correctly configured) I restarted lampp using ./lampp restart but problem remained. Then after turning on system today, I started lampp and everything worked just fine. No project issues anymore only command line Mysql not working

    Read the article

  • GNU Screen: Combining split-regions and full-screen sessions

    - by scrrr
    Let's say I have three sessions: 0, 1 and 2 I'm on session 0 and I press CTRL-A S to split the screen. Then I select session 1 for the bottom split region, while 0 is in the upper. Can I switch to session 2 and have it display in full-screen while 0 and 1 remain split? If I CTRL-A n to other sessions in a split screen it only changes the split-region. I want some sessions to be full-screen though. Is that possible?

    Read the article

  • Zip only public directory

    - by Nino55
    Hi guys, I've a lot of websites (100+ directories) I want to create a unique zip with only public subdirectory. My structure now is like: - Site 1 --- app --- tmp --- log --- public - Site 2 --- app --- tmp --- log --- public - ... 100+ dirs ... Now I need a unique zip and then after unzip it I want to see this structure: - Site 1 --- public - Site 2 --- public - others Any suggestion how I can do that with linux commands zip/tar ? Thanks so much!

    Read the article

  • What does the @ symbol mean in a file's permission settings?

    - by Shiki
    I'm on MacOSX, I did ln -s on a directory and these are the results: -rwxrwxr-x@ 1 shiki admin 970332 Mar 6 16:38 apc.so -rwxrwxr-x@ 1 shiki admin 653884 Mar 6 16:38 eaccelerator.so -rw-rw-r--@ 1 shiki admin 60064 Mar 6 16:38 gettext.a -rwxrwxr-x@ 1 shiki admin 80320 Mar 6 16:38 gettext.so -rw-rw-r--@ 1 shiki admin 514784 Mar 6 16:38 imap.a -rwxrwxr-x@ 1 shiki admin 3886132 Mar 6 16:38 imap.so What do those @ symbols mean?

    Read the article

  • Alternative shell apps for OS X

    - by Joseph Silvashy
    This might sound ridiculous, but my eyes are tired of looking at the crappy font rendering in OS X's Terminal.app, is there anything you guys recommend? I know it's like one of those things that you can easily say, "It's shell! what more can you ask for!" but really, all these great methods for rendering fonts and anti-aliasing, and we developers haven't even integrated that into our most trusty tool... at least that I know of. Anyhow, let's discus shell alternatives, thoughts?

    Read the article

  • Alternative terminal emulators for OS X

    - by Joseph Silvashy
    This might sound ridiculous, but my eyes are tired of looking at the crappy font rendering in OS X's Terminal.app, is there anything you guys recommend? I know it's like one of those things that you can easily say, "It's shell! what more can you ask for!" but really, all these great methods for rendering fonts and anti-aliasing, and we developers haven't even integrated that into our most trusty tool... at least that I know of. Anyhow, let's discus shell alternatives, thoughts?

    Read the article

  • Installing MFC (vs2005) application on Windows 2008 R2 64

    - by olich
    I've build an application that runs on Windows 2003, it is an old style MFC application. Today I need to install the application on a Windows 2008 R2 64 system. I have failures during installation and the application does not run. The application is build with VisualStudio2005, and uses COM objects. The MSI register the objects but it fails with the error code : HRESULT -2147010895. Any idea why the COM registration failed? I've tried to install the "Microsoft Visual C++ 2005 Redistributable Package (x86)" but it doesn't help. I've tried to register the COM objects with the regsvr32 after the installation but sadly it doesn't help. I've tries to install the application on Windows 2008 R2 32, and it works perfectly. I am quite new with 64 systems, so any help will be appreciated. tia olich

    Read the article

  • Let putty watch for specific output in stdout and notify

    - by GrzegorzOledzki
    Do you know any way to introduce a notification feature to putty client? I would like to setup some regular expressions or simply text strings and be notified (by sound or some tooltip) when this content appears in stdout. If not specific in putty, how can I get it done? There used to be a similar feature in older version of KDE's konsole terminal, but even now I can't see it.

    Read the article

  • Missing hvc0 in Ubuntu Lucid Xen DomU

    - by Joril
    I've just installed an Ubuntu Lucid 64bit image (from Stacklet) as a Xen DomU, running under Xen 3.2.1 on Centos 5.2 64bit. Everything is working fine, except my logs are flooded with: /dev/hvc0: No such file or directory I tried creating the device with mknod /dev/hvc0 c 229 0 but the message just changes to: /dev/hvc0: cannot open as standard input: No such device or address Any hint on what I could try? :(

    Read the article

  • Srvany Starts but Application doesn't

    - by mharran
    I used Instsrv and Srvany as to create a service on W2008; the Srvany service starts okay but the application does not start. The application is TeamSpeak 3 btw. I don't think it's an issue with my W2008 setup as I have a previous version of the application set up the exact same way and running perfectly. Also, I have no problem manually starting the application even when I copy and paste into the 'Run' box the path used for the application by Srvany. I looked at Events but nothing there except notification that the service has entered the running state, didn't really expect any errors as the service has started even though the application hasn't. Any suggestions on what could be the problem?

    Read the article

  • How to get the summarized sizes of folders and their subfolders?

    - by Kau-Boy
    Let's say I want to get the size of each folder of a linux file system. When I use ls -la I don't really get the summarized size of the folders. If I use df I get the size of each mounted file system but that also doesn't help me. And with du I get the size of each subfolder and the summary of the whole file system. But I want to have only the summarized size of each folder within the ROOT folder of the file system. Is there any command to achiev that?

    Read the article

  • Windows 7 migration: How to move application settings?

    - by FrustratedWithFormsDesigner
    Migrating from WindowsXP Home to Windows 7 Pro. The last bit that I'm stuck on is migrating application settings, such as the settings for Opera, Firefox, MSN Messenger, and others. On the XP system, this all seems to be in "user/Local Settings" and "user/Application Data". On the Windos 7 system, there is a "user/AppData" folder as well as "user/Application Data" and "user/Local Settings". When I try to access "Application Data" and "Local Settings" on Windows 7, I get an "Access Denied" error (even though my user is an admin). So... if I can't copy my application settings files to "Application Data" and "Local Settings" on Windows 7, where to I copy them to?

    Read the article

  • Color in Cygwin terminal

    - by ForbesLindesay
    I've installed cygwin because I'm a bit fed up with the Windows terminal not being great. The only problem I'm having is the lack of colours. You can see the problem in the following 2 screenshots that display the same command: All I want is something which has a nice font, resizes properly (including proper behaviour when maximised) and support for colours. Ideally I'd like tabs too. This seems like a silly reason to end up buying a mac, so I'm hoping I can get all these things on windows somehow.

    Read the article

  • Multi-threaded .NET application blocks during file I/O when protected by Themida

    - by Erik Jensen
    As the title says I have a .NET application that is the GUI which uses multiple threads to perform separate file I/O and notice that the threads occasionally block when the application is protected by Themida. One thread is devoted to reading from serial COM port and another thread is devoted to copying files. What I experience is occasionally when the file copy thread encounters a network delay, it will block the other thread that is reading from the serial port. In addition to slow network (which can be transient), I can cause the problem to happen more frequently by making a PathFileExists call to a bad path e.g. PathFileExists("\\\\BadPath\\file.txt"); The COM port reading function will block during the call to ReadFile. This only happens when the application is protected by Themida. I have tried under WinXP, Win7, and Server 2012. In a streamlined test project, if I replace the .NET application with a MFC unmanaged application and still utilize the same threads I see no issue even when protected with Themida. I have contacted Oreans support and here is their response: The way that a .NET application is protected is very different from a native application. To protect a .NET application, we need to hook most of the file access APIs in order to "cheat" the .NET Framework that the application is protected. I guess that those special hooks (on CreateFile, ReadFile...) are delaying a bit the execution in your application and the problem appears. We did a test making those hooks as light as possible (with minimum code on them) but the problem still appeared in your application. The rest of software protectors that we tried (like Enigma, Molebox...) also use a similar hooking approach as it's the only way to make the .NET packed file to work. If those hooks are not present, the .NET Framework will abort execution as it will see that the original file was tampered (due to all Microsoft checks on .NET files) Those hooks are not present in a native application, that's why it should be working fine on your native application. Oreans support tried other software protectors such as Enigma Protector, Engima VirtualBox, and Molebox and all exhibit the exact same problem. What I have found as a work around is to separate out the file copy logic (where the file exists call is being made) to be performed in a completely separate process. I have experimented with converting the thread functions from unmanaged C++ to VB.NET equivalents (PathFileExists - System.IO.File.Exists and CreateFile/ReadFile - System.IO.Ports.SerialPort.Open/Read) and still see the same serial port read blocked when the file check or copy call is delayed. I have also tried setting the ReadFile to work asynchronously but that had no effect. I believe I am dealing with some low-level windows layer that no matter the language it exhibits a block on a shared resource -- and only when the application is executing under a single .NET process protected by Themida which evidently installs some hooks to allow .NET execution. At this time converting the entire application away from .NET is not an option. Nor is separating out the file copy logic to a separate task. I am wondering if anyone else has more knowledge of how a file operation can block another thread reading from a system port. I have included here example applications that show the problem: https://db.tt/cNMYfEIg - VB.NET https://db.tt/Y2lnTqw7 - MFC They are Visual Studio 2010 solutions. When running the themida protected exe, you can see when the FileThread counter pauses (executing the File.Exists call) while the ReadThread counter also pauses. When running non-protected visual studio output exe, the ReadThread counter does not pause which is how we expect it to function. Thanks!

    Read the article

  • Question about API and Web application code sharing

    - by opendd
    This is a design question. I have a multi part application with several user types. There is a user client for the patient that interacts with a web service. There is an API evolving behind the web service that will be exposed to institutional "users" and an interface for clinicians, researchers and admin types. The patient UI is Flex. The clinician/admin portion of the application is RoR. The API is RoR/rack based. The web service component is Java WS. All components access the same data source. These components are deployed as separate components to their own subdomains. This decision was made to allow for scaling the components individually as needed. Initially, the decision was made to split the code for the RoR Web application from the RoR API. This decision was made in the interests of security and keeping the components focused on specific tasks. Over the course of time, there is necessarily going to be overlap and I am second guessing my decision to keep the code totally separate. I am noticing code being lifted from the admin side being lifted, modified and used in the API. This being the case, I have been considering merging the Ruby based repositories. I am interested in ideas and insight on this situation along with the reasoning behind your thoughts. Thanks.

    Read the article

  • Software Architecture: Quality Attributes

    Quality is what all software engineers should strive for when building a new system or adding new functionality. Dictonary.com ambiguously defines quality as a grade of excellence. Unfortunately, quality must be defined within the context of a situation in that each engineer must extract quality attributes from a project’s requirements. Because quality is defined by project requirements the meaning of quality is constantly changing base on the project. Software architecture factors that indicate the relevance and effectiveness The relevance and effectiveness of architecture can vary based on the context in which it was conceived and the quality attributes that are required to meet. Typically when evaluating architecture for a specific system regarding relevance and effectiveness the following questions should be asked.   Architectural relevance and effectiveness questions: Does the architectural concept meet the needs of the system for which it was designed? Out of the competing architectures for a system, which one is the most suitable? If we look at the first question regarding meeting the needs of a system for which it was designed. A system that answers yes to this question must meet all of its quality goals. This means that it consistently meets or exceeds performance goals for the system. In addition, the system meets all the other required system attributers based on the systems requirements. The suitability of a system is based on several factors. In order for a project to be suitable the necessary resources must be available to complete the task. Standard Project Resources: Money Trained Staff Time Life cycle factors that affect the system and design The development life cycle used on a project can drastically affect how a system’s architecture is created as well as influence its design. In the case of using the software development life cycle (SDLC) each phase must be completed before the next can begin.  This waterfall approach does not allow for changes in a system’s architecture after that phase is completed. This can lead to major system issues when the architecture for the system is not as optimal because of missed quality attributes. This can occur when a project has poor requirements and makes misguided architectural decisions to name a few examples. Once the architectural phase is complete the concepts established in this phase must move on to the design phase that is bound to use the concepts and guidelines defined in the previous phase regardless of any missing quality attributes needed for the project. If any issues arise during this phase regarding the selected architectural concepts they cannot be corrected during the current project. This directly has an effect on the design of a system because the proper qualities required for the project where not used when the architectural concepts were approved. When this is identified nothing can be done to fix the architectural issues and system design must use the existing architectural concepts regardless of its missing quality properties because the architectural concepts for the project cannot be altered. The decisions made in the design phase then preceded to fall down to the implementation phase where the actual system is coded based on the approved architectural concepts established in the architecture phase regardless of its architectural quality. Conversely projects using more of an iterative or agile methodology to implement a system has more flexibility to correct architectural decisions based on missing quality attributes. This is due to each phase of the SDLC is executed more than once so any issues identified in architecture of a system can be corrected in the next architectural phase. Subsequently the corresponding changes will then be adjusted in the following design phase so that when the project is completed the optimal architectural and design decision are applied to the solution. Architecture factors that indicate functional suitability Systems that have function shortcomings do not have the proper functionality based on the project’s driving quality attributes. What this means in English is that the system does not live up to what is required of it by the stakeholders as identified by the missing quality attributes and requirements. One way to prevent functional shortcomings is to test the project’s architecture, design, and implementation against the project’s driving quality attributes to ensure that none of the attributes were missed in any of the phases. Another way to ensure a system has functional suitability is to certify that all its requirements are fully articulated so that there is no chance for misconceptions or misinterpretations by all stakeholders. This will help prevent any issues regarding interpreting the system requirements during the initial architectural concept phase, design phase and implementation phase. Consider the applicability of other architectural models When considering an architectural model for a project is also important to consider other alternative architectural models to ensure that the model that is selected will meet the systems required functionality and high quality attributes. Recently I can remember talking about a project that I was working on and a coworker suggested a different architectural approach that I had never considered. This new model will allow for the same functionally that is offered by the existing model but will allow for a higher quality project because it fulfills more quality attributes. It is always important to seek alternatives prior to committing to an architectural model. Factors used to identify high-risk components A high risk component can be defined as a component that fulfills 2 or more quality attributes for a system. An example of this can be seen in a web application that utilizes a remote database. One high-risk component in this system is the TCIP component because it allows for HTTP connections to handle by a web server and as well as allows for the server to also connect to a remote database server so that it can import data into the system. This component allows for the assurance of data quality attribute and the accessibility quality attribute because the system is available on the network. If for some reason the TCIP component was to fail the web application would fail on two quality attributes accessibility and data assurance in that the web site is not accessible and data cannot be update as needed. Summary As stated previously, quality is what all software engineers should strive for when building a new system or adding new functionality. The quality of a system can be directly determined by how closely it is implemented when compared to its desired quality attributes. One way to insure a higher quality system is to enforce that all project requirements are fully articulated so that no assumptions or misunderstandings can be made by any of the stakeholders. By doing this a system has a better chance of becoming a high quality system based on its quality attributes

    Read the article

< Previous Page | 62 63 64 65 66 67 68 69 70 71 72 73  | Next Page >