Search Results

Search found 10033 results on 402 pages for 'execution speed'.

Page 66/402 | < Previous Page | 62 63 64 65 66 67 68 69 70 71 72 73  | Next Page >

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Do glue records in non-circular dns-lookups speed up domain resolution or not?

    - by Joe Hopfgartner
    Doing a lookup for my domain on http://www.intodns.com/ I noticed theese two messages: In Parent section: DNS Parent sent Glue The parent nameserver g.gtld-servers.net is not sending out GLUE for every nameservers listed, meaning he is sending out your nameservers host names without sending the A records of those nameservers. It's ok but you have to know that this will require an extra A lookup that can delay a little the connections to your site. This happens a lot if you have nameservers on different TLD (domain.com for example with nameserver ns.domain.org.) and in NS section: Glue for NS records INFO: GLUE was not sent when I asked your nameservers for your NS records.This is ok but you should know that in this case an extra A record lookup is required in order to get the IPs of your NS records. The nameservers without glue are: 109.230.225.96 84.201.40.52 You can fix this for example by adding A records to your nameservers for the zones listed above. I do perfectly understand that the primary objective of glue records is to resolve circular dependencies. The classic use case: my domain is example.com and I want to have the nameserver ns1.example.com. This will never work because i cannot know the ip of ns1.example.com if I don't fetch example.com and in order to do that I need to fetch it from ns1.example.com. To resolve this deadlock I add a glue record to ns1.example.com containing the ip adress of the nameserver, so this can work out. So this problem does not occour if the nameservers are in a different TLD than the domain i want to look up. But however to fetch the zone information from the nameservers I need to know their ip adress right? And in order to know that i need to fetch the zone the nameservers are in from their respective nameservers, right? (or rather my ISP needs to do that in the background) So an extra lookup that takes time? If I now have glue records, I know the IP adress right away without the need to look it up - so this should speed up the resolution of my domain, shouldnt it? However my DNS zone provider (tecserver.at) replied that this would make no sense because "we are not running ns1.ourdomain.com an ns1.ourdomain.com as authorative NS for ourdomain.com. This would be the only sense for glue records. Tecserver has a glue record because the NS for tecserver.at are ns1.tecserver.at and ns2.tecserver.at. Therefore a glue record is needed for resolution.

    Read the article

  • Time to stop using &ldquo;Execute Package Task&rdquo;&ndash; a way to execute package in SSIS catalog taking advantage of the new project deployment model ,and the logging and reporting feature

    - by Kevin Shyr
    I set out to find a way to dynamically call package in SSIS 2012.  The following are 2 excellent blogs I found; I used them heavily.  The code below has some addition to parameter types and message types, but was made essentially derived entirely from the blogs. http://sqlblog.com/blogs/jamie_thomson/archive/2011/07/16/ssis-logging-in-denali.aspx http://www.ssistalk.com/2012/07/24/quick-tip-run-ssis-2012-packages-synchronously-and-other-execution-options/   The code: Every package will be called by a PackageController package.  The packageController is initialized with some information on which package to run and what information to pass in.   The following is the stored procedure called from the “Execute SQL Task”.  Here is the highlight of the stored procedure It takes in packageName, project name, and folder name (folder in SSIS project deployment to SSIS catalog) The stored procedure sets the package variables of the upcoming package execution Execute package in SSIS Catalog Get the status of the execution.  Also, if exists, get the error message’s message_id and store them in the management database. Return value to “Execute SQL Task” to manage failure properly CREATE PROCEDURE [AUDIT].[LaunchPackageExecutionInSSISCatalog]        @PackageName NVARCHAR(255)        , @ProjectFolder NVARCHAR(255)        , @ProjectName NVARCHAR(255)        , @AuditKey INT        , @DisableNotification BIT        , @PackageExecutionLogID INT AS BEGIN TRY        DECLARE @execution_id BIGINT = 0;        -- Create a package execution        EXEC [SSISDB].[catalog].[create_execution]                     @package_name=@PackageName,                     @execution_id=@execution_id OUTPUT,                     @folder_name=@ProjectFolder,                     @project_name=@ProjectName,                     @use32bitruntime=False;          UPDATE [AUDIT].[PackageInstanceExecutionLog] WITH(ROWLOCK)        SET [SSISCatalogExecutionID] = @execution_id        WHERE [PackageInstanceExecutionLogID] = @PackageExecutionLogID          -- this is to set the execution synchronized so that I can check the result in the end        EXEC [SSISDB].[catalog].[set_execution_parameter_value]                     @execution_id,                      @object_type=50,                     @parameter_name=N'SYNCHRONIZED',                     @parameter_value=1; -- true          /********************************************************         ********************************************************              Section: setting parameters                     Source table:  SSISDB.internal.object_parameters              object_type list:                     20: project level variables                     30: package level variables                     50: execution parameter         ********************************************************         ********************************************************/        EXEC [SSISDB].[catalog].[set_execution_parameter_value]                     @execution_id,                      @object_type=30,                     @parameter_name=N'FromParent_AuditKey',                     @parameter_value=@AuditKey; -- true          EXEC [SSISDB].[catalog].[set_execution_parameter_value]                     @execution_id,                      @object_type=30,                     @parameter_name=N'FromParent_DisableNotification',                     @parameter_value=@DisableNotification; -- true          EXEC [SSISDB].[catalog].[set_execution_parameter_value]                     @execution_id,                      @object_type=30,                     @parameter_name=N'FromParent_PackageInstanceExecutionID',                     @parameter_value=@PackageExecutionLogID; -- true        /********************************************************         ********************************************************              Section: setting variables END         ********************************************************         ********************************************************/            /* This section is carried over from example code           I don't see a reason to change them yet        */        -- Set our package parameters        EXEC [SSISDB].[catalog].[set_execution_parameter_value]                     @execution_id,                      @object_type=50,                     @parameter_name=N'DUMP_ON_EVENT',                     @parameter_value=1; -- true          EXEC [SSISDB].[catalog].[set_execution_parameter_value]                     @execution_id,                      @object_type=50,                     @parameter_name=N'DUMP_EVENT_CODE',                     @parameter_value=N'0x80040E4D;0x80004005';          EXEC [SSISDB].[catalog].[set_execution_parameter_value]                     @execution_id,                      @object_type=50,                     @parameter_name=N'LOGGING_LEVEL',                     @parameter_value= 1; -- Basic          EXEC [SSISDB].[catalog].[set_execution_parameter_value]                     @execution_id,                      @object_type=50,                     @parameter_name=N'DUMP_ON_ERROR',                     @parameter_value=1; -- true                              /********************************************************         ********************************************************              Section: EXECUTING         ********************************************************         ********************************************************/        EXEC [SSISDB].[catalog].[start_execution]                     @execution_id;        /********************************************************         ********************************************************              Section: EXECUTING END         ********************************************************         ********************************************************/            /********************************************************         ********************************************************              Section: checking execution result                     Source table:  [SSISDB].[catalog].[executions]              status:                     1: created                     2: running                     3: cancelled                     4: failed                     5: pending                     6: ended unexpectedly                     7: succeeded                     8: stopping                     9: completed         ********************************************************         ********************************************************/        if EXISTS(SELECT TOP 1 1                            FROM [SSISDB].[catalog].[executions] WITH(NOLOCK)                            WHERE [execution_id] = @execution_id                                  AND [status] NOT IN (2, 7, 9)) BEGIN                /********************************************************               ********************************************************                     Section: logging error messages                            Source table:  [SSISDB].[internal].[operation_messages]                     message type:                            10:  OnPreValidate                             20:  OnPostValidate                             30:  OnPreExecute                             40:  OnPostExecute                             60:  OnProgress                             70:  OnInformation                             90:  Diagnostic                             110:  OnWarning                            120:  OnError                            130:  Failure                            140:  DiagnosticEx                             200:  Custom events                             400:  OnPipeline                     message source type:                            10:  Messages logged by the entry APIs (e.g. T-SQL, CLR Stored procedures)                             20:  Messages logged by the external process used to run package (ISServerExec)                             30:  Messages logged by the package-level objects                             40:  Messages logged by tasks in the control flow                             50:  Messages logged by containers (For, ForEach, Sequence) in the control flow                             60:  Messages logged by the Data Flow Task                                    ********************************************************               ********************************************************/                INSERT INTO AUDIT.PackageInstanceExecutionOperationErrorLink                     SELECT @PackageExecutionLogID                                  ,[operation_message_id]                            FROM [SSISDB].[internal].[operation_messages] WITH(NOLOCK)                            WHERE operation_id = @execution_id                                  AND message_type IN (120, 130)                           EXEC [AUDIT].[FailPackageInstanceExecution] @PackageExecutionLogID, 'SSISDB Internal operation_messages found'                GOTO ReturnTrueAsErrorFlag                /********************************************************               ********************************************************                     Section: checking messages END               ********************************************************               ********************************************************/                /* This part is not really working, so now using rowcount to pass status              --DECLARE @PackageErrorMessage NVARCHAR(4000)              --SET @PackageErrorMessage = @PackageName + 'failed with executionID: ' + CONVERT(VARCHAR(20), @execution_id)                --RAISERROR (@PackageErrorMessage -- Message text.              --     , 18 -- Severity,              --     , 1 -- State,              --     , N'check table AUDIT.PackageInstanceExecutionErrorMessages' -- First argument.              --     );              */        END        ELSE BEGIN              GOTO ReturnFalseAsErrorFlagToSignalSuccess        END        /********************************************************         ********************************************************              Section: checking execution result END         ********************************************************         ********************************************************/ END TRY BEGIN CATCH        DECLARE @SSISCatalogCallError NVARCHAR(MAX)        SELECT @SSISCatalogCallError = ERROR_MESSAGE()          EXEC [AUDIT].[FailPackageInstanceExecution] @PackageExecutionLogID, @SSISCatalogCallError          GOTO ReturnTrueAsErrorFlag END CATCH;     /********************************************************  ********************************************************    Section: end result  ********************************************************  ********************************************************/ ReturnTrueAsErrorFlag:        SELECT CONVERT(BIT, 1) AS PackageExecutionErrorExists ReturnFalseAsErrorFlagToSignalSuccess:        SELECT CONVERT(BIT, 0) AS PackageExecutionErrorExists   GO

    Read the article

  • Is there a way to tell SGE to run specific jobs as root on the execution node?

    - by Rick Reynolds
    The title kinda says it all... We're using SGE/OGE to submit jobs to a set of worker nodes that then do things with specific pieces of equipment. The programs and scripts that have been created that manipulate this equipment rely on running as root. I'd like SGE to handle allocation of resources in a way that is mindful of users, groups, projects, etc., but I also need the actual jobs to run with root permissions. I've read up on How can one run a prologue script as root in gridengine? to see if anything there was pertinent, but it seems that SGE is providing the "user@" kind of spec specifically for prolog and epilog kinds of actions. Is there any similar functionality for the job itself? I'm aware of su/sudo approaches, but that won't really work in this environment because the sudoers file isn't globally managed (i.e. I'd have to add a whole set of users to /etc/sudoers on lots of machines). I'm currently looking into a setuid kind of solution, but that would definitely be an unnecessary kind of work-around if SGE provides me a way to declare that a specific job (or jobs in a specific queue) always needs to run with a specific user's rights.

    Read the article

  • How to automate an Amazon EC2 instance startup, execution of some commands and shutdown?

    - by Howiecamp
    I need to download 100 GB of files (it’s in about 150 files) within a 7 day period before they expire. The download is rate-limited by the host so it takes MUCH longer than the theoretical transfer rate based on normal Internet speeds. I have a script of curl http://curl.haxx.se/docs/manpage.html commands - one line per file. I had the idea of automatically spinning up n EC2 instances, executing the command and FTPing the files to a central location, then shutting down the machines. How would I do this? I don't care whether it's Linux or Windows.

    Read the article

  • Weird Network Behavior of Home Router

    - by Stilgar
    First of all I would like to apologize because what you are going to read will be long and confusing but I am fighting this issue for 3 days now and am out of ideas. At home I have the following setup 50Mbps Internet connects into a home router A 2 desktop computers connect to router A via standard FTP LAN cables including one where the cable is ~20m long. a second router B connects to router A via standard FTP LAN cable X (~20m long). several devices connect to the wireless network of router B and there are a couple of desktop computers connected to it through FTP LAN cables. For some reason computers connected to router B when it is connected via cable X have very slow Internet connection. It is like 5 times slower than what is expected. This is the actual problem I am trying to solve. Interesting facts If a computer is connected to cable X directly instead of through router B the Internet speed is just fine (up to the 50Mbps I get from the ISP). Tested with two computers. I have tried replacing router B with another router C and the problem persists. If I connect router B via another cable to the same ports with the same settings everything seems to work fine and computers connected to router B have quite fast Internet I have tested mainly via Speedtest.net but I have also achieved similar speeds when downloading a file The upload speed is quite higher than the download speed in all cases. Note that my ISP usually has higher upload speed (unless it manages to hit the 50Mbps cap) It seems like the speed when connecting through router B with cable X is reduced 4-5 times no matter what the original speed is. For example via router B I get 10Mbps speed to local servers where I get 50Mbps when connected on router A. If I use a distant server where the ISP is only able to provide 25Mbps I get 4-5Mbps on router B. WiFi is slower than LAN on both routers (which is normal) but the reduced speed is reduced proportionally for WiFi. In addition the upload speed is normally higher from the ISP and it is also reduced proportionally. I have tried two different network configurations. One where I have NAT behind NAT where router B connects to router A via the WAN port and has its own DHCP. Second where router B connects to router A via standard LAN port and has DHCP disabled. In this configuration router B serves as a switch and the Network Gateway for computers connected to router B is the internal IP address of router A. Both configurations work just fine but both manifest the reduced speed issue. pings seem to work just fine As far as I can tell none of the cables is crossed The RJ45 setup for cable X orange orange-white brown brow-white blue blue-white green green-white This is a big problem for me since cable X passes through walls and floors and is very hard to replace. I also may have gotten some of the facts wrong because I am almost going crazy with this issue and testing includes going several floors up and down the staircase. One hypothesis I came up with is that the cable is defective in such a way that the voltage from the router affects its performance. When it is connected to a computer it performs just fine but the router has less power. Related hypothesis includes the cable being affected by electricity cables in the walls when the voltage is low. (I know nothing about electricity) So any ideas what to do, what to test or what the issue may be?

    Read the article

  • Is execution of sync(8) still required before shutting down linux?

    - by Amos Shapira
    I still see people recommend use of "sync; sync; sync; sleep 30; halt" incantations when talking about shutting down or rebooting Linux. I've been running Linux since its inception and although this was the recommended procedure in the BSD 4.2/4.3 and SunOS 4 days, I can't recall that I had to do that for at least the last ten years, during which I probably went through shutdown/reboot of Linux maybe thousands of times. I suspect that this is an anachronism since the days that the kernel couldn't unmount and sync the root filesystem and other critical filesystems required even during single-user mode (e.g. /tmp), and therefore it was necessary to tell it explicitly to flush as much data as it can to disk. These days, without finding the relevant code in the kernel source yet (digging through http://lxr.linux.no and google), I suspect that the kernel is smart enough to cleanly unmount even the root filesystem and the filesystem is smart enough to effectively do a sync(2) before unmounting itself during a normal "shutdown"/"reboot"/"poweorff". The "sync; sync; sync" is only necessary in extreme cases where the filesystem won't unmount cleanly (e.g. physical disk failure) or the system is in a state that only forcing a direct reboot(8) will get it out of its freeze (e.g. the load is too high to let it schedule the shutdown command). I also never do the "sync" procedure before unmounting removable devices, and never hit a problem. Another example - Xen allows the DomU to be sent a "shutdown" command from the Dom0, this is considered a "clean shutdown" without anyone having to login and type the magical "sync; sync; sync" first. Am I right or was I lucky for a few thousands of system shutdowns?

    Read the article

  • Vertical Scrolling In Tile Based XNA Platformer

    - by alec100_94
    I'm making a 2D platformer in XNA 4.0. I have created a working tile engine, which works well for my purposes, and Horizontal Scrolling works flawlessly, however I am having great trouble with Vertical scrolling. I Basically want the camera to scroll up (world to scroll down) when the player reaches a certain Y co-ordinate, and I would also like to automatically scroll back down if coming down, and that co-ordinate is passed. My biggest problem is I have no real way of detecting the direction the player is moving in using only the Y Co-ord. Here Is My Code Code For The Camera Class (which appears to be a very different approach to most camera classes I have seen). using System; using System.Collections.Generic; using System.Linq; using System.Text; using Microsoft.Xna.Framework; namespace Marvin { class Camera : TileEngine { public static bool startReached; public static bool endReached; public static void MoveRight(float speed = 2) { //Moves The Position of Each Tile Right foreach (Tile t in tiles) { if(t!=null) { t.position.X -= speed; } } } public static void MoveLeft(float speed = 2) { //Moves The Position of Each Tile Right foreach (Tile t in tiles) { if(t!=null) { t.position.X += speed; } } } public static void MoveUp(float speed = 2) { foreach (Tile t in tiles) { if(t!=null) { t.position.Y += speed; } } } public static void MoveDown(float speed = 2) { foreach (Tile t in tiles) { if(t!=null) { t.position.Y -= speed; } } } public static void Restrain() { if(tiles.Last().position.X<Main.graphics.PreferredBackBufferWidth-tiles.Last().size.X) { MoveLeft(); endReached = true; } else { endReached = false; } if(tiles[1].position.X>0) { MoveRight(); startReached = true;} else { startReached = false; } } } } Here is My Player Code for Left and Right Scrolling/Moving if (Main.currentKeyState.IsKeyDown(Keys.Right)) { Camera.MoveRight(); if(Camera.endReached) { MoveRight(2); } else { if(marvin.GetRectangle().X!=Main.graphics.PreferredBackBufferWidth-(marvin.GetRectangle().X+marvin.GetRectangle().Width)) { MoveRight(2); Camera.MoveLeft(); } } } if(Main.currentKeyState.IsKeyDown(Keys.Left)) { Camera.MoveLeft(); if(Camera.startReached) { MoveLeft(2); } else { if(marvin.GetRectangle().X!=Main.graphics.PreferredBackBufferWidth-(marvin.GetRectangle().X+marvin.GetRectangle().Width)) { MoveLeft(2); Camera.MoveRight(); } } } Camera.Restrain(); if(marvin.GetRectangle().X>Main.graphics.PreferredBackBufferWidth-marvin.GetRectangle().Width) { MoveLeft(2); } if(marvin.GetRectangle().X<0) { MoveRight(2); } And Here Is My Player Jumping/Falling Code which may cause some conflicts with the vertical camera movement. if (!jumping) { if(!TileEngine.TopOfTileCollidingWith(footBounds)) { MoveDown(5); } else { if(marvin.GetRectangle().Y != TileEngine.LastPlatformStoodOnTop()-marvin.GetRectangle().Height) { float difference = (TileEngine.LastPlatformStoodOnTop()-marvin.GetRectangle().Height) - (marvin.GetRectangle().Y); marvin.SetRectangle(marvin.GetRectangle().X,(int)(marvin.GetRectangle().Y+difference)); armR.SetRectangle(armR.GetRectangle().X,(int)(armR.GetRectangle().Y+difference)); armL.SetRectangle(armL.GetRectangle().X,(int)(armL.GetRectangle().Y+difference)); eyeL.SetRectangle(eyeL.GetRectangle().X,(int)(eyeL.GetRectangle().Y+difference)); eyeR.SetRectangle(eyeR.GetRectangle().X,(int)(eyeR.GetRectangle().Y+difference)); } } } if (Main.currentKeyState.IsKeyDown(Keys.Up) && Main.previousKeyState.IsKeyUp(Keys.Up) && TileEngine.TopOfTileCollidingWith(footBounds)) { jumping = true; } if(jumping) { if(TileEngine.LastPlatformStoodOnTop()>0 && (TileEngine.LastPlatformStoodOnTop() - footBounds.Bottom)<120) { MoveUp(5); } else { jumping = false; } } All player code I have tried for vertical movements has failed, or caused weird results (like falling through platforms), and most have been a variation on the method I described above, hence I have not included it. I would really appreciate some help implementing a simple vertical scrolling into this game, Thanks.

    Read the article

  • puppet execution of a python script where os.system(...) command is not working

    - by philippe
    I am trying to manage Unix users with puppet. Puppet provides enough tools to create accounts and provide authorized_keys files for instance, but no to set up user password, and it tell to the user. What I have done is a python script which generate a random password and send it to the user by email. The problem is, it is not possible to launch passwd Unix command with python, I have then written a bash script with the command: echo -ne "$password\n$password\n" | passwd $user passwd -e $user Launched manually, the script works fine and the created user has its password sent by email. But when puppet launches it, only the python script gets executed, as if the os.system('/bin/bash my_bash_script') is ignored. No error is displayed. And the user gets its password, but the passwd commands are not launched. Is there any limitation with puppet preventing to perform what I described? Or, how can I otherwise change the user account, its expiration, and send password by email? I can provide more information, but right now, I don't know which are accurate. Many thanks!

    Read the article

  • Why is execution of batch files different between drag & drop and from command line?

    - by Dharma Leonardi
    Ok, so I've been trying to figure this out for hours with no progress. I have created a batch file to get details of a VHD. Everything runs fine and produces the expected results when run from the command line in a command prompt. However, when I use drag and drop from file explorer (dragging a vhd file and dropping onto the batch file) the batch file runs without errors but the output (VHD.INFO) is empty. I'm stumped. Edited to only include the behaviour: @echo off cls setlocal enabledelayedexpansion set "_PATH.THIS=%~dp0" echo HELP | diskpart > %_PATH.THIS%OUTPUT.TMP TYPE %_PATH.THIS%OUTPUT.TMP PAUSE To demonstrate the different behaviour, please run the batch file from the command line once (works) and also run the batch file by double clicking in file explorer (failure in all piping commands).

    Read the article

  • How to time batch file execution using timethis.exe?

    - by unknown
    While timethis.exe works fine for almost every application, it seems to fail for .bat files: C:\test>timethis test.bat TimeThis : Command Line : test.bat TimeThis : Start Time : Fri Feb 26 19:46:30 2010 'test.bat' is not recognized as an internal or external command, operable program or batch file. TimeThis : Command Line : test.bat TimeThis : Start Time : Fri Feb 26 19:46:30 2010 TimeThis : End Time : Fri Feb 26 19:46:30 2010 TimeThis : Elapsed Time : 00:00:00.070 While executing it on a regular command line is fine, timethis.exe fails for it. How do I fix this problem?

    Read the article

  • How to extract $lastexitcode from c# powershell script execution.

    - by scope-creep
    Hi, I've got a scipt executing in C# using the powershell async execution code on code project here: http://www.codeproject.com/KB/threads/AsyncPowerShell.aspx?display=PrintAll&fid=407636&df=90&mpp=25&noise=3&sort=Position&view=Quick&select=2130851#xx2130851xx I need to return the $lastexitcode and Jean-Paul describes how you can use a custom pshost class to return it. I can't find any method or property in pshost that returns the exit code. This engine I have needs to ensure that script executes correctly. Any help would be appreciated. regards Bob. Its the $lastexitcode and the $? variables I need to bring back. Hi, Finally answered. I found out about the $host variable. It implements a callback into the host, specifically a custom PSHost object, enabling you to return the $lastexitcode. Here is a link to an explanation of $host. http://mshforfun.blogspot.com/2006/08/do-you-know-there-is-host-variable.html It seems to be obscure, badly documented, as usual with powershell docs. Using point 4, calling $host.SetShouldExit(1) returns 1 to the SetShouldExit method of pshost, as described here. http://msdn.microsoft.com/en-us/library/system.management.automation.host.pshost.setshouldexit(VS.85).aspx Its really depends on defining your own exit code defintion. 0 and 1 suffixes I guess. regards Bob.

    Read the article

  • Why is my WPF splash screen progress bar out of sync with the execution of the startup steps?

    - by denny_ch
    Hello, I've implemented a simple WPF splash screen window which informs the user about the progress of the application startup. The startup steps are defined this way: var bootSequence = new[] { new {Do = (Action) InitLogging, Message = "Init logging..."}, new {Do = (Action) InitNHibernate, Message = "Init NHibernate..."}, new {Do = (Action) SetupUnityContainer, Message = "Init Unity..."}, new {Do = (Action) UserLogOn, Message = "Logon..."}, new {Do = (Action) PrefetchData, Message = "Caching..."}, }; InitLogging etc. are methods defined elsewhere, which performs some time consuming tasks. The boot sequence gets executed this way: foreach (var step in bootSequence) { _status.Update(step.Message); step.Do(); } _status denotes an instance of my XAML splash screen window containing a progress bar and a label for status information. Its Update() method is defined as follows: public void Update(string status) { int value = ++_updateSteps; Update(status, value); } private void Update(string status, int value) { var dispatcherOperation = Dispatcher.BeginInvoke( DispatcherPriority.Background, (ThreadStart) delegate { lblStatus.Content = status; progressBar.Value = value; }); dispatcherOperation.Wait(); } In the main this works, the steps get executed and the splash screen shows the progress. But I observed that the splash screen for some reasons doesn't update its content for all steps. This is the reason I called the Dispatcher async and wait for its completion. But even this didn't help. Has anyone else experienced this or some similar behaviour and has some advice how to keep the splash screen's update in sync with the execution of the boot sequence steps? I know that the users will unlikely notice this behaviour, since the splash screen is doing something and the application starts after booting is completed. But myself isn't sleeping well, because I don't know why it is not working as expected... Thx for your help, Denny

    Read the article

  • Can LINQ expression classes implement the observer pattern instead of deferred execution?

    - by Tormod
    Hi. We have issues within an application using a state machine. The application is implemented as a windows service and is iteration based (it "foreaches" itself through everything) and there are myriads of instances being processed by the state machine. As I'm reading the MEAP version of Jon Skeets book "C# in Depth, 2nd ed", I'm wondering if I can change the whole thing to use linq expression instances so that guards and conditions are represented using expression trees. We are building many applications on this state machine engine and would probably greatly benefit from the new Expression tree visualizer in VS 2010 Now, simple example. If I have an expression tree where there is an OR Expression condition with two sub nodes, is there any way that these can implement the observer pattern so that the expression tree becomes event driven? If a condition change, it should notify its parent node (the OR node). Since the OR node then changes from "false" to "true", then it should notify ITS parent and so on. I love the declarative model of expression trees, but the deferred execution model works in opposite direction of the control flow if you want event based "live" conditions. Am I off on a wild goose chase here? Or is there some concept in the BCL that may help me achieve this?

    Read the article

  • Will my LinqToSql execution be deffered if i filter with IEnumerable<T> instead of IQueryable<T>?

    - by cottsak
    I have been using these common EntityObjectFilters as a "pipes and filters" way to query from a collection a particular item with an ID: public static class EntityObjectFilters { public static T WithID<T>(this IQueryable<T> qry, int ID) where T : IEntityObject { return qry.SingleOrDefault<T>(item => item.ID == ID); } public static T WithID<T>(this IList<T> list, int ID) where T : IEntityObject { return list.SingleOrDefault<T>(item => item.ID == ID); } } ..but i wondered to myself: "can i make this simpler by just creating an extension for all IEnumerable<T> types"? So i came up with this: public static class EntityObjectFilters { public static T WithID<T>(this IEnumerable<T> qry, int ID) where T : IEntityObject { return qry.SingleOrDefault<T>(item => item.ID == ID); } } Now while this appears to yield the same result, i want to know that when applied to IQueryable<T>s will the expression tree be passed to LinqToSql for evaluating as SQL code or will my qry be evaluated in it's entirety first, then iterated with Funcs? I'm suspecting that (as per Richard's answer) the latter will be true which is obviously what i don't want. I want the same result, but the added benefit of the delayed SQL execution for IQueryable<T>s. Can someone confirm for me what will actually happen and provide simple explanation as to how it would work?

    Read the article

  • .NET framework execution aborted while executing CLR stored procedure?

    - by Sean Ochoa
    I constructed a stored procedure that does the equivalent of FOR XML AUTO in SQL Server 2008. Now that I'm testing it, it gives me a really unhelpful error message. What does this error mean? Msg 10329, Level 16, State 49, Procedure ForXML, Line 0 .NET Framework execution was aborted. System.Threading.ThreadAbortException: Thread was being aborted. System.Threading.ThreadAbortException: at System.Runtime.InteropServices.Marshal.PtrToStringUni(IntPtr ptr, Int32 len) at System.Data.SqlServer.Internal.CXVariantBase.WSTRToString() at System.Data.SqlServer.Internal.SqlWSTRLimitedBuffer.GetString(SmiEventSink sink) at System.Data.SqlServer.Internal.RowData.GetString(SmiEventSink sink, Int32 i) at Microsoft.SqlServer.Server.ValueUtilsSmi.GetValue(SmiEventSink_Default sink, ITypedGettersV3 getters, Int32 ordinal, SmiMetaData metaData, SmiContext context) at Microsoft.SqlServer.Server.ValueUtilsSmi.GetValue200(SmiEventSink_Default sink, SmiTypedGetterSetter getters, Int32 ordinal, SmiMetaData metaData, SmiContext context) at System.Data.SqlClient.SqlDataReaderSmi.GetValue(Int32 ordinal) at System.Data.SqlClient.SqlDataReaderSmi.GetValues(Object[] values) at System.Data.ProviderBase.DataReaderContainer.CommonLanguageSubsetDataReader.GetValues(Object[] values) at System.Data.ProviderBase.SchemaMapping.LoadDataRow() at System.Data.Common.DataAdapter.FillLoadDataRow(SchemaMapping mapping) at System.Data.Common.DataAdapter.FillFromReader(DataSet dataset, DataTable datatable, String srcTable, DataReaderContainer dataReader, Int32 startRecord, Int32 maxRecords, DataColumn parentChapterColumn, Object parentChapterValue) at System.Data.Common.DataAdapter.Fill(DataTable[] dataTables, IDataReader dataReader, Int32 startRecord, Int32 maxRecords) at System.Data.Common.DbDataAdapter.FillInternal(DataSet dataset, DataTable[] datatables, Int32 startRecord, Int32 maxRecords, String srcTable, IDbCommand command, CommandBehavior behavior) at System.Data.Common.DbDataAdapter.Fill(DataTable[] dataTables, Int32 startRecord, Int32 maxRecords, IDbCommand command, CommandBehavior behavior) at System.Data.Common.DbDataAdapter.Fill(DataTable dataTable) at ForXML.GetXML...

    Read the article

  • Is safe ( documented behaviour? ) to delete the domain of an iterator in execution

    - by PoorLuzer
    I wanted to know if is safe ( documented behaviour? ) to delete the domain space of an iterator in execution in Python. Consider the code: import os import sys sampleSpace = [ x*x for x in range( 7 ) ] print sampleSpace for dx in sampleSpace: print str( dx ) if dx == 1: del sampleSpace[ 1 ] del sampleSpace[ 3 ] elif dx == 25: del sampleSpace[ -1 ] print sampleSpace 'sampleSpace' is what I call 'the domain space of an iterator' ( if there is a more appropriate word/phrase, lemme know ). What I am doing is deleting values from it while the iterator 'dx' is running through it. Here is what I expect from the code : Iteration versus element being pointed to (*): 0: [*0, 1, 4, 9, 16, 25, 36] 1: [0, *1, 4, 9, 16, 25, 36] ( delete 2nd and 5th element after this iteration ) 2: [0, 4, *9, 25, 36] 3: [0, 4, 9, *25, 36] ( delete -1th element after this iteration ) 4: [0, 4, 9, 25*] ( as the iterator points to nothing/end of list, the loop terminates ) .. and here is what I get: [0, 1, 4, 9, 16, 25, 36] 0 1 9 25 [0, 4, 9, 25] As you can see - what I expect is what I get - which is contrary to the behaviour I have had from other languages in such a scenario. Hence - I wanted to ask you if there is some rule like "the iterator becomes invalid if you mutate its space during iteration" in Python? Is it safe ( documented behaviour? ) in Python to do stuff like this?

    Read the article

  • How to avoid concurrent execution of a time-consuming task without blocking?

    - by Diego V
    I want to efficiently avoid concurrent execution of a time-consuming task in a heavily multi-threaded environment without making threads wait for a lock when another thread is already running the task. Instead, in that scenario, I want them to gracefully fail (i.e. skip its attempt to execute the task) as fast as possible. To illustrate the idea considerer this unsafe (has race condition!) code: private static boolean running = false; public void launchExpensiveTask() { if (running) return; // Do nothing running = true; try { runExpensiveTask(); } finally { running = false; } } I though about using a variation of Double-Checked Locking (consider that running is a primitive 32-bit field, hence atomic, it could work fine even for Java below 5 without the need of volatile). It could look like this: private static boolean running = false; public void launchExpensiveTask() { if (running) return; // Do nothing synchronized (ThisClass.class) { if (running) return; running = true; try { runExpensiveTask(); } finally { running = false; } } } Maybe I should also use a local copy of the field as well (not sure now, please tell me). But then I realized that anyway I will end with an inner synchronization block, that still could hold a thread with the right timing at monitor entrance until the original executor leaves the critical section (I know the odds usually are minimal but in this case we are thinking in several threads competing for this long-running resource). So, could you think in a better approach?

    Read the article

  • How to check successful copy() function execution in php?

    - by OM The Eternity
    How to check successful copy() function execution in php? I am using the following code: <? function full_copy( $source, $target ) { if ( is_dir( $source ) ) { @mkdir( $target ); $d = dir( $source ); while ( FALSE !== ( $entry = $d->read() ) ) { if ( $entry == '.' || $entry == '..' ) { continue; } $Entry = $source . '/' . $entry; if ( is_dir( $Entry ) ) { full_copy( $Entry, $target . '/' . $entry ); continue; } copy( $Entry, $target . '/' . $entry ); } $d->close(); }else { copy( $source, $target ); } } $source ='.'; $destination = '/html/parth/'; full_copy($source, $destination); ?> I do not get anything in my parth folder. Why? I am using Windows, Script is executed on fedora system (its my server)...

    Read the article

  • Is it worth purchasing Mahout in Action to get up to speed with Mahout, or are there other better sources?

    - by gab
    I'm currently a very casual user of Apache Mahout, and I'm considering purchasing the book Mahout in Action. Unfortunately, I'm having a really hard time getting an idea of how worth it this book is -- and seeing as it's a Manning Early Access Program book (and therefore only currently available as a beta-version e-book), I can't take a look myself in a bookstore. Can anyone recommend this as a good (or less good) guide to getting up to speed with Mahout, and/or other sources that can supplement the Mahout website?

    Read the article

  • How can I replace/speed up a text search query which uses LIKE ?

    - by Jules
    I'm trying to speed up my query... select PadID from Pads WHERE (keywords like '%$search%' or ProgramName like '%$search%' or English45 like '%$search%') AND RemovemeDate = '2001-01-01 00:00:00' ORDER BY VersionAddDate DESC I've done some work already, I have a keywords table so I can add ... PadID IN (SELECT PadID FROM Keywords WHERE word = '$search') ... However its going to be a nightmare to split up the words from English45 and ProgramName into a word table. Any ideas ? EDIT : (also provided actual table names)

    Read the article

< Previous Page | 62 63 64 65 66 67 68 69 70 71 72 73  | Next Page >