Search Results

Search found 5121 results on 205 pages for 'dll'.

Page 67/205 | < Previous Page | 63 64 65 66 67 68 69 70 71 72 73 74  | Next Page >

  • How come .net 4.0 and .net 2.0 CLR's can exist in a same machine

    - by Vinni
    I have a basic doubt that, How can we have both CLR's on a same machine. If this is possible, When I refer few dll's of 4.0 and setting application pool to 2.0 why Cant I run the website(I am getting errors).When we refer the dll's from web.config it means it searches for GAC when that particular 4.0 dll is available in GAC Why dont it load (How come it is not loading).. Please clarify my doubts

    Read the article

  • C#: How do I get the path of the assembly the code is in?

    - by George Mauer
    Is there a way to get the path for the assembly in which the current code resides? I do not want the path of the calling assembly, just the one containing the code. Basically my unit test needs to read some xml test files which are located relative to the dll. I want the path to always resolve correctly regardless of whether the testing dll is run from TestDriven.NET, the MbUnit GUI or something else. Edit: People seem to be misunderstanding what I'm asking. My test library is located in say c:\projects\myapplication\daotests\bin\Debug\daotests.dll and I would like to get the "*c:\projects\myapplication\daotests\bin\Debug*" path. The three suggestions so far fail me when I run from the MbUnit Gui: Console.Out.Write(Environment.CurrentDirectory) gives c:\Program Files\MbUnit Console.Out.Write(System.Reflection.Assembly.GetAssembly(typeof(DaoTests)).Location) gives C:\Documents and Settings\george\Local Settings\Temp\ ....\DaoTests.dll Console.Out.Write(System.Reflection.Assembly.GetExecutingAssembly().Location) gives the same as the previous

    Read the article

  • C#, DI, IOC using Castle Windsor

    - by humblecoder
    Hi! Am working on a design of a project. I would like to move the implementation away hence to decouple am using interfaces. interface IFoo { void Bar(); void Baz(); } The assemblies which implemented the above interface would be drop in some predefined location say "C:\Plugins" for eg: project: A class A : IFoo { } when compiled produces A.dll project: B class A : IFoo { } when compiled produced B.dll Now I would like to provide a feature in my application to enable end use to configure the assembly to be loaded in the database.say C:\Plugins\A.dll or C:\Plugins\B.dll How it can be achieved using Castle Windsor. container.AddComponent("identifier",load assembly from specified location as configured in DB); I would like to do something like this: IFoo foo =container.Resolve("identifier"); foo.Bar(); //invoke method. Any hint would be highly appreciated. Thanks, Hamed.

    Read the article

  • Can I use pdb files to step through a 3rd party assembly?

    - by Pure.Krome
    Hi folks, my friend has made a really helpful class library which I use all the time. I usually use Reflector to see what his code does. What I really wanted to do was to step through his code while I'm debugging. So he gave me his .pdb file. Foo.dll (release configuration, compile) Foo.pdb Now, I'm not sure how I can get it to auto break into his code when it throws an exception (his code, at various points, thorws exceptions .. like A first chance exception of type 'System.Web.HttpException' occurred in Foo.dll ... Can I do this? Do i need to setup something with the Symbol Server settings in Visual Studio ? Do i need to get the dll compiled into Debug Configuration and be passed the .dll and .pdb files? Or (and i'm really afraid of this one) .. do i need to have both the .dll, .pdb AND his source code ... I also had a look at this previous SO question, but it sorta didn't help (but proof I've tried to search before asking a question). Can someone help me please?

    Read the article

  • Unregistering a COM wrapped .NET assembly

    - by flopdix
    I created a COM exposed .NET 2.0 dll and registered with my windows operating system using 'regasm' and 'gacutil' (in GAC). Then I tried to call this component from my classic ASP page. It worked fine. But, I need to change the functionality of my assembly. I unregistered it again using 'regasm' and 'gacutil' (from GAC) utilities and copied my new .NET DLL and registered again (This time using a new version of the DLL). For some reason, i still have a pointer to my old assembly and new calls to the DLL from ASP page are not working. Any Ideas on what process i need to follow to ensure that all the references to the old version are completely removed? I appreciate any help.

    Read the article

  • Adding a new target type to msbuild: How do I refer to the itemname in the task rules?

    - by jmucchiello
    I'm trying to add a task to build the COM proxy DLL after building the main DLL. So I created the following in a .target file: <Target Name="ProxyDLL" Inputs="$(IntDir)%(WHATGOESHERE)_i.c;$(IntDir)dlldata.c" Outputs="$(OutDir)%(WHATGOESHERE)ps.dll" AfterTargets="Link"> <CL Sources="$(IntDir)%(WHATGOESHERE)_i.c;$(IntDir)dlldata.c" /> </Target> And reference it from the .vcxproj file as <ItemGroup> <ProxyDLL Include="FTAccountant" /> </ItemGroup> So the FTAccountant.DLL file is created through the normal build process and then when attempts to compile the proxy stubs it creates these command lines: cl /c dir\_i.c dir\dlldata.c And of course it can't find _i.c. The first attempt, I put %(Filename) in the WHATGOESHERE space and I got this error: C:\ActivePay\Build\Proxy DLL.targets(6,3): error MSB4095: The item metadata %(Filename) is being referenced without an item name. Specify the item name by using %(itemname.Filename). So I changed it to %(itemname.Filename) and that is an empty string. How to get the value specified in the task's Include attribute and use it within the task?

    Read the article

  • Calling 32 bit unmanaged dlls from C# randomly failing

    - by Bert
    Hi, I'm having an issue when calling 32 bit delphi dll's from c# web site. The code generally runs fine, but occasionally I get an error Unable to load DLL '': The specified module could not be found. (Exception from HRESULT: 0x8007007E). This issue persists until I recycle the app pool for the site, and then it works fine again. On the same server, there is also a web service that is calling the same set of dlls. This web service doesn't seem to have the same issue that the web site has. Both applications are using .net framework 3.5, separate app pools on IIS. Here is the code I'm using to wrap the dlls: public sealed class Mapper { static Mapper instance = null; [DllImport("kernel32.dll")] private static extern bool SetDllDirectory(string lpPathName); private Mapper() { SetDllDirectory(ConfigManager.Path); } public static Mapper Instance { get { if (instance == null) { instance = new Mapper(); } return instance; } } public int Foo(string bar, ref double val) { return Loader.Foo(bar, ref val); } } public static class Loader { [DllImport("some.dll", CallingConvention = CallingConvention.StdCall, CharSet = CharSet.Unicode, EntryPoint = "foo")] public static extern int Foo(string bar, ref double val); } Then I call it like this: double val = 0.0; Mapper.Instance.Foo("bar", ref val); Any ideas as to why it would "randomly" Unable to load DLL '': The specified module could not be found. (Exception from HRESULT: 0x8007007E). The other problem is that I haven't been able to replicate the issue in the development environment. I thought that due to 2 applications calling the same dlls, that there could be some locks occurring. To replicate this, I created an app that spawned multiple threads and repeatedly called the 32bit dlls, and then used the web site to call these same dlls. I still couldn't replicate the issue. Some possible fixes that I can think of: Wrap the 32 bit dlls in web service (because the webservice doesn't seem to suffer from the same problem). But this may be worthless if it turns out that the web service also fails. Set up state server for the session state and periodically recycle the app pool for the site.This isn't fixing the problem, only avoiding it. Wrap the dll's in exe, and call that exe. Then I shouldn't get the same issue. But this also seems like a hacky solution. Implement the mapper class differently ? But how else should I be doing the call? The other draw back is that other applications are using this mapper, so I'd need to change there code too. Thanks

    Read the article

  • C Run-Time library part 2

    - by b-gen-jack-o-neill
    Hi, I was suggested when I have some further questions on my older ones, to create newer Question and reffer to old one. So, this is the original question: What is the C runtime library? OK, from your answers, I now get thet statically linked libraries are Microsoft implementation of C standart functions. Now: If I get it right, the scheme would be as follow: I want to use printf(), so I must include which just tels compiler there us functio printf() with these parameters. Now, when I compile code, becouse printf() is defined in C Standart Library, and becouse Microsoft decided to name it C Run Time library, it gets automatically statically linked from libcmt.lib (if libcmt.lib is set in compiler) at compile time. I ask, becouse on wikipedia, in article about runtime library there is that runtime library is linked in runtime, but .lib files are linked at compile time, am I right? Now, what confuses me. There is .dll version of C standart library. But I thought that to link .dll file, you must actually call winapi program to load that library. So, how can be these functions dynamically linked, if there is no static library to provide code to tell Windows to load desired functions from dll? And really last question on this subject - are C Standart library functions also calls to winapi even they are not .dll files like more advanced WinAPI functions? I mean, in the end to access framebuffer and print something you must tell Windows to do it, since OS cannot let you directly manipulate HW. I think of it like the OS must be written to support all C standart library functions same way across similiar versions, since they are statically linked, and can differently support more complex WinAPI calls becouse new version of OS can have adjustements in the .dll file.

    Read the article

  • ASP.NET plug-in architecture, settings problem

    - by Xaqron
    I want to divide business layer (BLL) of an asp.net application into multiple components. Each component is a .NET class library which is compiled as a standalone DLL. These components should have their own configuration files. For example "MyNameSpace.Users.dll" contains classes about users of the website and there's a password policy to check if password length is at least x characters. When webmaster edits the config file of this DLL and set x to y then component (DLL) should use new value (y) in the future and enforce passwords to be at least y characters. I want each component as a single project and compile them separaely (and not to put all projects in a solution in Visual Studio), and put the DLLs of these libraries into the "Bin" folder of my ASP.NET application. Is it possible ? Where should I put these config files ?

    Read the article

  • Call Babel .Net Obfuscator from C# Code

    - by aron
    Hello, I have a C# WinForms app that I use to create software patches for my app. In noticed that Babel .Net includes Babel.Build.dll and Babel.Code.dll Is there a way, in my C# code, I can call Babel .Net something like: ExecuteCommand(C:\Program Files\Babel\babel.exe "C:\Patch\v6\Demo\Bin\Lib.dll" --rules "C:\Patch\babelRules.xml", 600) Here's a common script to execute a CMD prompt in C#. However if I just include the Babel.Build.dll in my winform I may be able to do it seamlessly. public static int ExecuteCommand(string Command, int Timeout) { int ExitCode; ProcessStartInfo ProcessInfo; Process Process; ProcessInfo = new ProcessStartInfo("cmd.exe", "/C " + Command); ProcessInfo.CreateNoWindow = true; ProcessInfo.UseShellExecute = false; Process = Process.Start(ProcessInfo); Process.WaitForExit(Timeout); ExitCode = Process.ExitCode; Process.Close(); return ExitCode; }

    Read the article

  • Do I need to force the GAC to reload an assembly? Is this possible?

    - by Ben McCormack
    I've added types to my .NET classes that I'm using for COM interop. To get it to work with my VB6 application, I unregistered the DLL and re-registered it (using regasm). I then uninstalled and reinstalled it to the GAC (using gacutil). The types are showing up in the VB6 object explorer, but when I run the application in the VB6 IDE, it breaks on the line that instantiates the new types with the error: Automation Errror - The System cannot find the file specified. I thought this odd since I had already updated the GAC, so I uninstalled the dll from the GAC and got the exact same error, which seems to indicate that the older version of the dll is already in memory and needs to be "reloaded" so that the newer DLL is in memory. Is this possible, and if so, what do I need to do?

    Read the article

  • How do I solve "Two different CRTLDLLs are loaded" when using packages in C++ Builder 2010?

    - by David M
    Hi, We are trying to split up our monolithic EXE into a combination of an EXE and several packages. So far, we have one package that we're trying to use, and when running the EXE Codeguard shows the following error on startup: CG Error Two different CRTLDLLs are loaded. CG might report false errors (C:\Windows\system32\CC32100MT.DLL) (D:\Projects\Foo\Bar.bpl) OK I read this as two different runtime libraries being loaded - one, the correct one (CC32100MT.dll), one incorrect, which is the package we're trying to use. Continuing to run the program shows odd errors, especially casting between classes or passing a pointer to a class as a parameter in a method that crosses the EXE/DLL boundary. Codeguard itself doesn't show any other errors at all though. How do we solve this? Some more details We've looked at as many things as we (the developer working on this and I) can collectively think of: Each project is built using runtime packages. The EXE host lists Bar in its package list. Each project is set to compile with dynamic RTL. However, changing this does not solve the problem. The package is linked to the EXE via its BPI file, but linking via a LIB makes no difference either. The EXE and BPL are compiled with the same project settings, where the same options exist for both types of project. We think, anyway :) There is only one copy of the BPL and BPI on the system: it's definitely linking to the right one. Examining the EXE and BPL with Depends and TDump show they are both using C:\Windows\system32\CC32100MT.DLL. They should both be using the one RTL. Creating a new project (a plain VCL forms application) and linking to the BPL (via its BPI) works fine. Something in the process of adding all the files and LIBs that make our EXE contain the code it needs to changes this, but we haven't been able to figure out what. The LIBs all either correspond to DLLs we use (flat C interface, usually look as though they were built with MSVC) or are simple projects with lots of related files, compiled to a lib for the purpose of linking into the EXE - these correspond roughly to the areas of the program we want to split to BPLs, by the way. There don't seem to be project options for the LIB projects that would affect RTL linking, unless we've missed them. I have exhaustively hunted through Depends and looked at all RTL and CC32*.dll files the EXE and every single DLL references. All are identical: rtl140.bpl and CC32100MT.DLL. Fully qualified paths show they are the same files, too. Everything should be using the one same run-time library. We're stumped. Absolutely stumped. We've had other problems using BPLs (they seem to be surprisingly tricky things, especially using C++) but have managed to solve them all. This one we've had no luck at all and we'd really appreciate any insights :) We're using C++Builder 2010 (as part of RAD Studio actually, but with little Delphi code apart from components.)

    Read the article

  • Storage location of yellow-blue shield icon

    - by gencha
    Where, in Windows, is this icon stored? I need to use it in a TaskDialog emulation for XP and am having a hard time tracking it down. It's not in shell32.dll, explorer.exe, ieframe.dll or wmploc.dll (as these contain a lot of icons commonly used in Windows).

    Read the article

  • "Reference required" error when referencing NServiceBus assembly from another project

    - by cwegrzyn
    We are trying to write an application that uses the NServiceBus library in a VB.NET environment. We've been stymied by errors similar to the following: Reference required to assembly 'NServiceBus, Version=2.0.0.1071, Culture=neutral, PublicKeyToken=9fc386479f8a226c' containing the implemented interface 'NServiceBus.IMessageHandler`1'. Add one to your project. Our project already includes references to NServiceBus.dll and NServiceBus.Core.dll from the same NServiceBus 2.0 RC2 distribution. Steps to reproduce: Create a new VB Class Library Project (.NET 3.5) Add NServiceBus.dll and NServiceBus.Core.dll as References. Put the following code in Class1.vb: Imports NServiceBus.Sagas.Impl Class Test Public Function Foo() As SagaMessageHandler Return Nothing End Function End Class You should now see the compiler error mentioned above. An identical project written in C# has no compile errors. Any ideas about how to solve this problem? (And, yes, my preferred solution is switching to C#, but no, that's not an acceptable one at the moment.)

    Read the article

  • Getting started on a stream interface driver

    - by Ranhiru
    I want to build a stream interface driver for testing purposes but I am completely lost. I don't know which IDE to use VS2008 or Platform Builder. Platform Builder is whopping 20GB to download :( Can anyone guide me on how i create the .dll file and include XXX_Open, XXX_Close, XXX_Write, XXX_Read in the dll file? Should i write the .dll file in C++ or can i write it in C#? Please guide me through the basics :) Thanx a lot :)

    Read the article

  • operator "new" returning a non-local heap pointer for only one class ?

    - by KaluSingh Gabbar
    Language : C++ Platform : Windows Server 2003 I have an exe calling a DLL, in which when I allocate (new) the memory for class A (which is in DLL) it returns me a non-local heap pointer. I try to new other classes which are in DLL and "new" returns a valid heap pointer for them, its only Class A which is not being allocated properly. I am on windows and validating the heap by this function call : _CrtIsValidHeapPointer ( (const void *) pPtr ) I am seriously confused why this only happens with new-ing Class A and no other class ? (All Native Code)

    Read the article

  • Unable to delete file locked by same process -- weird!

    - by user300266
    I have an application written in PHP that uses a COM dll written in C#. The dll creates an image file by combining two other image files. The PHP script then takes over to do the housekeeping tasks of deleting the two source files and renaming the resulting combined file. The problem is the PHP script can't delete one of the source files because it's locked. The weird thing is that the process that has it locked is itself which in this case is the Apache Web Server. I have tried altering the C# dll to dispose of all bitmap and graphics objects prior to exiting, and yet the lock remains. My question is, what can I do to get the dll to let go and release the file locks. This is very frustrating.

    Read the article

  • When should we put an Assembly into GAC?

    - by Amitabh
    I would like to know practically what kind of Assembly should we put in GAC. Case 1. If in my Solution multiple project uses log4net.dll then should it be part of GAC? Case 2. If I have multiple application deployed in a machine each using log4net.dll is this the reason enough to put log4net.dll into GAC?

    Read the article

  • Importing into a Exported object with MEF

    - by Nathan W
    I'm sorry if this question has already been asked 100 times, but I'm really struggling to get it to work. Say I have have three projects. Core.dll Has common interfaces Shell.exe Loads all modules in assembly folder. References Core.dll ModuleA.dll Exports Name, Version of module. References Core.dll Shell.exe has a [Export] that contains an single instance of a third party application that I need to inject into all loaded modules. So far the code that I have in Shell.exe is: static void Main(string[] args) { ThirdPartyApp map = new ThirdPartyApp(); var ad = new AssemblyCatalog(Assembly.GetExecutingAssembly()); var dircatalog = new DirectoryCatalog("."); var a = new AggregateCatalog(dircatalog, ad); // Not to sure what to do here. } class Test { [Export(typeof(ThirdPartyApp))] public ThirdPartyApp Instance { get; set; } [Import(typeof(IModule))] public IModule Module { get; set; } } I need to create a instance of Test, and load Instance with map from the Main method then load the Module from ModuleA.dll that is in the executing directory then [Import] Instance into the loaded module. In ModuleA I have a class like this: [Export(IModule)] class Module : IModule { [Import(ThirdPartyApp)] public ThirdPartyApp Instance {get;set;} } I know I'm half way there I just don't know how to put it all together, mainly with loading up test with a instance of map from Main. Could anyone help me with this.

    Read the article

  • Debugged Program Window Won't Close

    - by Marc Bernier
    Hi, I'm using VS 2008 on a 64-bit XP machine. I'm debugging a 32-bit C++ DLL via a console program. The DLL and EXE projects are contained in the same SLN so that I can modify the DLL as I test. What happens is that every once in a while I kill the program with Debug | Stop Debugging (Shift-F5). VS stops the program, but the console window stays open! If I'm sitting at a breakpoint and hit Shift-F5, it will terminate properly, but if the program is running full-tilt when I stop it, I often see this instead. The big problem is that I can't close these zombie windows. Using End Task in Task Manager does nothing (no message, no nothing). When I shut down the machine, it is unable to due to the orphans and I have to resort to actually turning off the power. I think this is connected to having the DLL and EXE project in the same SLN, as for months I worked on this project in 2 VS instances, one for the DLL and the other for the EXE. I would continually jump back and forth between the windows as I worked. This problem never happened until I put the two projects into a single SLN. The single SLN works a lot better, but this anomaly is very irritating. Any ideas anyone? UPDATE After a bit of searching (here), I found that it appears to have to do with one of the updates from last Tuesday (KB977165 or KB978037). Thank you Microsoft for your excellent pre-release testing.

    Read the article

  • Using SQLite from PowerShell on Windows 7x64?

    - by jas
    I'm having a difficult time trying to load System.Data.SQLite.dll from PowerShell in Windows 7 x64. # x64 [void][System.Reflection.Assembly]::LoadFrom("C:\projects\PSScripts\lib\System.Data.SQLite.x64.DLL") # x86 #[void][System.Reflection.Assembly]::LoadFrom("C:\projects\PSScripts\lib\System.Data.SQLite.DLL") $conn = New-Object -TypeName System.Data.SQLite.SQLiteConnection $conn.ConnectionString = "Data Source=C:\temp\PSData.db" $conn.Open() $command = $conn.CreateCommand() $command.CommandText = "select DATETIME('NOW') as now, 'Bar' as Foo" $adapter = New-Object -TypeName System.Data.SQLite.SQLiteDataAdapter $command $dataset = New-Object System.Data.DataSet [void]$adapter.Fill($dataset) Trying to open the connection with the x64 assembly results in: Exception calling "Open" with "0" argument(s): "An attempt was made to load a program with an incorrect format. (Exception from HRESULT: 0x8007000B)" Trying to load the x86 assembly results in: Exception calling "LoadFrom" with "1" argument(s): "Could not load file or assembly 'file:///C:\projects\PSScripts\lib\System.Data.SQLite.DLL' or one of its dependencies. An attempt was made to load a program with an incorrect format." Any thoughts or ideas?

    Read the article

  • Unable to Calculate Position within Owner-Draw Text

    - by Jonathan Wood
    I'm trying to use Visual Studio 2012 to create a Windows Forms application that can place the caret at the current position within a owner-drawn string. However, I've been unable to find a way to accurately calculate that position. I've done this successfully before in C++. I've now tried numerous methods in C#. Originally, I tried using .NET classes to determine the correct position, but then I tried accessing the Windows API directly. In some cases, I came close, but after some time I still cannot place the caret accurately. I've created a small test program and posted key parts below. I've also posted the entire project here. The exact font used is not important to me; however, my application assumes a mono-spaced font. Any help is appreciated. Form1.cs This is my main form. public partial class Form1 : Form { private string TestString; private int AveCharWidth; private int Position; public Form1() { InitializeComponent(); TestString = "123456789012345678901234567890123456789012345678901234567890"; AveCharWidth = GetFontWidth(); Position = 0; } private void Form1_Load(object sender, EventArgs e) { Font = new Font(FontFamily.GenericMonospace, 12, FontStyle.Regular, GraphicsUnit.Pixel); } protected override void OnGotFocus(EventArgs e) { Windows.CreateCaret(Handle, (IntPtr)0, 2, (int)Font.Height); Windows.ShowCaret(Handle); UpdateCaretPosition(); base.OnGotFocus(e); } protected void UpdateCaretPosition() { Windows.SetCaretPos(Padding.Left + (Position * AveCharWidth), Padding.Top); } protected override void OnLostFocus(EventArgs e) { Windows.HideCaret(Handle); Windows.DestroyCaret(); base.OnLostFocus(e); } protected override void OnPaint(PaintEventArgs e) { e.Graphics.DrawString(TestString, Font, SystemBrushes.WindowText, new PointF(Padding.Left, Padding.Top)); } protected override bool IsInputKey(Keys keyData) { switch (keyData) { case Keys.Right: case Keys.Left: return true; } return base.IsInputKey(keyData); } protected override void OnKeyDown(KeyEventArgs e) { switch (e.KeyCode) { case Keys.Left: Position = Math.Max(Position - 1, 0); UpdateCaretPosition(); break; case Keys.Right: Position = Math.Min(Position + 1, TestString.Length); UpdateCaretPosition(); break; } base.OnKeyDown(e); } protected int GetFontWidth() { int AverageCharWidth = 0; using (var graphics = this.CreateGraphics()) { try { Windows.TEXTMETRIC tm; var hdc = graphics.GetHdc(); IntPtr hFont = this.Font.ToHfont(); IntPtr hOldFont = Windows.SelectObject(hdc, hFont); var a = Windows.GetTextMetrics(hdc, out tm); var b = Windows.SelectObject(hdc, hOldFont); var c = Windows.DeleteObject(hFont); AverageCharWidth = tm.tmAveCharWidth; } catch { } finally { graphics.ReleaseHdc(); } } return AverageCharWidth; } } Windows.cs Here are my Windows API declarations. public static class Windows { [Serializable, StructLayout(LayoutKind.Sequential, CharSet = CharSet.Auto)] public struct TEXTMETRIC { public int tmHeight; public int tmAscent; public int tmDescent; public int tmInternalLeading; public int tmExternalLeading; public int tmAveCharWidth; public int tmMaxCharWidth; public int tmWeight; public int tmOverhang; public int tmDigitizedAspectX; public int tmDigitizedAspectY; public short tmFirstChar; public short tmLastChar; public short tmDefaultChar; public short tmBreakChar; public byte tmItalic; public byte tmUnderlined; public byte tmStruckOut; public byte tmPitchAndFamily; public byte tmCharSet; } [DllImport("user32.dll")] public static extern bool CreateCaret(IntPtr hWnd, IntPtr hBitmap, int nWidth, int nHeight); [DllImport("User32.dll")] public static extern bool SetCaretPos(int x, int y); [DllImport("User32.dll")] public static extern bool DestroyCaret(); [DllImport("User32.dll")] public static extern bool ShowCaret(IntPtr hWnd); [DllImport("User32.dll")] public static extern bool HideCaret(IntPtr hWnd); [DllImport("gdi32.dll", CharSet = CharSet.Auto)] public static extern bool GetTextMetrics(IntPtr hdc, out TEXTMETRIC lptm); [DllImport("gdi32.dll")] public static extern IntPtr SelectObject(IntPtr hdc, IntPtr hgdiobj); [DllImport("GDI32.dll")] public static extern bool DeleteObject(IntPtr hObject); }

    Read the article

  • Visual Studio 2008 Unit test does not pick up code changes unless I build the entire solution

    - by Orion Edwards
    Here's the scenario: Change my code: Change my unit test for that code With the cursor inside the unit test class/method, invoke VS2008's "Run tests in current context" command The visual studio "Output" window indicates that the code dll and the test dll both successfully build (in that order) The problem is however, that the unit test does not use the latest version of the dll which it has just built. Instead, it uses the previously built dll (which doesn't have the updated code in it), so the test fails. When adding a new method, this results in a MethodNotImplementedException, and when adding a class, it results in a TypeLoadException, both because the unit test thinks the new code is there, and it isn't!. If I'm just updating an existing method, then the test just fails due to incorrect results. I can 'work around' the problem by doing this Change my code: Change my unit test for that code Invoke VS2008's 'Build Solution' command With the cursor inside the unit test class/method, invoke VS2008's "Run tests in current context" command The problem is that doing a full build solution (even though nothing has changed) takes upwards of 30 seconds, as I have approx 50 C# projects, and VS2008 is not smart enough to realize that only 2 of them need to be looked at. Having to wait 30 seconds just to change 1 line of code and re-run a unit test is abysmal. Is there anything I can do to fix this? None of my code is in the GAC or anything funny like that, it's just ordinary old dll's (buiding against .NET 3.5SP1 on a win7/64bit machine) Please help!

    Read the article

  • Parallel Task In C#.net

    - by Test123
    I have C#.net application. I wanted to run my application In Thread. But because of third party dll it dont allow to use application in multiThread. There is one object in thrid party dll ,which only allow to create instance at one time only. When i manually run application exe instnace multiple time & process my data it process successfully..(might because of each exe run with its application domain) Same thing i require to implement from C# code. for that i have created dll which can accessible by Type.GetTypeFromProgID()..but multiple dll instnace creating same problem. Is there any way i could achive manual parallelism through code to process same exe code in multiple application domain?

    Read the article

  • How to remove the MenuBar of an application using windows API ?

    - by karthik
    I am using the below code to remove the Title Bar of an application, which is working perfectly for notepad. Now i want to remove the Menu Bar also. How to achieve it ? //Finds a window by class name [DllImport("USER32.DLL")] public static extern IntPtr FindWindow(string lpClassName, string lpWindowName); //Sets a window to be a child window of another window [DllImport("USER32.DLL")] public static extern IntPtr SetParent(IntPtr hWndChild, IntPtr hWndNewParent); //Sets window attributes [DllImport("USER32.DLL")] public static extern int SetWindowLong(IntPtr hWnd, int nIndex, int dwNewLong); //Gets window attributes [DllImport("USER32.DLL")] public static extern int GetWindowLong(IntPtr hWnd, int nIndex); [DllImport("user32.dll", EntryPoint = "FindWindow", SetLastError = true)] static extern IntPtr FindWindowByCaption(IntPtr ZeroOnly, string lpWindowName); //assorted constants needed public static int GWL_STYLE = -16; public static int WS_BORDER = 0x00800000; //window with border public static int WS_DLGFRAME = 0x00400000; //window with double border but no title public static int WS_CAPTION = WS_BORDER | WS_DLGFRAME; //window with a title bar public void WindowsReStyle() { Process[] Procs = Process.GetProcesses(); foreach (Process proc in Procs) { if (proc.ProcessName.StartsWith("notepad")) { IntPtr pFoundWindow = proc.MainWindowHandle; int style = GetWindowLong(pFoundWindow, GWL_STYLE); SetWindowLong(pFoundWindow, GWL_STYLE, (style & ~WS_CAPTION)); } } }

    Read the article

< Previous Page | 63 64 65 66 67 68 69 70 71 72 73 74  | Next Page >