Search Results

Search found 25196 results on 1008 pages for 'hard drive cache'.

Page 67/1008 | < Previous Page | 63 64 65 66 67 68 69 70 71 72 73 74  | Next Page >

  • Is there any free software to check for issues with a DVD drive?

    - by AgentConundrum
    I don't usually play movies on my laptop (prefer the standalone with the tv), but I tried to watch one the other night, and noticed playback was really choppy and had audio artifacts in places. I thought it could be related to memory issues so I rebooted and tried again, but the results were the same. I considered that it could be an issue with the disc, so I tried to clean it but again there was no change. I don't think the problem is with the disc, because I tried another disc and it also had the same problem. I don't think I've ever watched the second disc since I've had it, so it should have been safe in its jewel case. Also, there were no issues when I watched an episode off the first disc in my standalone player. What I'm wondering is: are there are any (free) utilities that can check for issues with the drive itself? I looked around but most of the software I found focuses on integrity checks for the disc, not the drive. I have had issues with this laptop recently (had to replace the keyboard when the cat damaged it while I was cleaning dust out and the machine was ripped apart, also replaced part of the chassis after I cracked it when I tried to open it not knowing a screw was still in it) so I may have just replaced the drive incorrectly. I'm going to check on this while I await an answer to this question. Thanks.

    Read the article

  • Why is Varnish not caching?

    - by Justin
    I am troubleshooting the setup of Varnish 3.x on my Ubuntu server. I'm running Drupal 7 on two sites set up on the box, via named-based vhosts. Before trying to get Varnish to play nice with Drupal I'm trying to just get Varnish to a PNG from cache. Here are the headers I get from a curl -I request of the PNG file: HTTP/1.1 200 OK Server: Apache/2.2.22 (Ubuntu) Last-Modified: Sun, 07 Oct 2012 21:18:59 GMT ETag: "a57c2-3850-4cb7ea73db6c0" Accept-Ranges: bytes Content-Length: 14416 Cache-Control: max-age=1209600 Expires: Thu, 25 Oct 2012 22:55:14 GMT Content-Type: image/png Accept-Ranges: bytes Date: Thu, 11 Oct 2012 22:55:14 GMT X-Varnish: 1766703058 Age: 0 Via: 1.1 varnish Connection: keep-alive X-Varnish-Cache: MISS Here is the Varnish VCL file I'm using (It's a default VCL configuration designed for Drupal): # Default backend definition. Set this to point to your content # server. # backend default { .host = "127.0.0.1"; .port = "8080"; } # Respond to incoming requests. sub vcl_recv { # Use anonymous, cached pages if all backends are down. if (!req.backend.healthy) { unset req.http.Cookie; } # Allow the backend to serve up stale content if it is responding slowly. set req.grace = 6h; # Pipe these paths directly to Apache for streaming. #if (req.url ~ "^/admin/content/backup_migrate/export") { # return (pipe); #} # Do not cache these paths. if (req.url ~ "^/status\.php$" || req.url ~ "^/update\.php$" || req.url ~ "^/admin$" || req.url ~ "^/admin/.*$" || req.url ~ "^/flag/.*$" || req.url ~ "^.*/ajax/.*$" || req.url ~ "^.*/ahah/.*$") { return (pass); } # Do not allow outside access to cron.php or install.php. #if (req.url ~ "^/(cron|install)\.php$" && !client.ip ~ internal) { # Have Varnish throw the error directly. # error 404 "Page not found."; # Use a custom error page that you've defined in Drupal at the path "404". # set req.url = "/404"; #} # Always cache the following file types for all users. This list of extensions # appears twice, once here and again in vcl_fetch so make sure you edit both # and keep them equal. if (req.url ~ "(?i)\.(pdf|asc|dat|txt|doc|xls|ppt|tgz|csv|png|gif|jpeg|jpg|ico|swf|css|js)(\?.*)?$") { unset req.http.Cookie; } # Remove all cookies that Drupal doesn't need to know about. We explicitly # list the ones that Drupal does need, the SESS and NO_CACHE. If, after # running this code we find that either of these two cookies remains, we # will pass as the page cannot be cached. if (req.http.Cookie) { # 1. Append a semi-colon to the front of the cookie string. # 2. Remove all spaces that appear after semi-colons. # 3. Match the cookies we want to keep, adding the space we removed # previously back. (\1) is first matching group in the regsuball. # 4. Remove all other cookies, identifying them by the fact that they have # no space after the preceding semi-colon. # 5. Remove all spaces and semi-colons from the beginning and end of the # cookie string. set req.http.Cookie = ";" + req.http.Cookie; set req.http.Cookie = regsuball(req.http.Cookie, "; +", ";"); set req.http.Cookie = regsuball(req.http.Cookie, ";(SESS[a-z0-9]+|SSESS[a-z0-9]+|NO_CACHE)=", "; \1="); set req.http.Cookie = regsuball(req.http.Cookie, ";[^ ][^;]*", ""); set req.http.Cookie = regsuball(req.http.Cookie, "^[; ]+|[; ]+$", ""); if (req.http.Cookie == "") { # If there are no remaining cookies, remove the cookie header. If there # aren't any cookie headers, Varnish's default behavior will be to cache # the page. unset req.http.Cookie; } else { # If there is any cookies left (a session or NO_CACHE cookie), do not # cache the page. Pass it on to Apache directly. return (pass); } } } # Set a header to track a cache HIT/MISS. sub vcl_deliver { if (obj.hits > 0) { set resp.http.X-Varnish-Cache = "HIT"; } else { set resp.http.X-Varnish-Cache = "MISS"; } } # Code determining what to do when serving items from the Apache servers. # beresp == Back-end response from the web server. sub vcl_fetch { # We need this to cache 404s, 301s, 500s. Otherwise, depending on backend but # definitely in Drupal's case these responses are not cacheable by default. if (beresp.status == 404 || beresp.status == 301 || beresp.status == 500) { set beresp.ttl = 10m; } # Don't allow static files to set cookies. # (?i) denotes case insensitive in PCRE (perl compatible regular expressions). # This list of extensions appears twice, once here and again in vcl_recv so # make sure you edit both and keep them equal. if (req.url ~ "(?i)\.(pdf|asc|dat|txt|doc|xls|ppt|tgz|csv|png|gif|jpeg|jpg|ico|swf|css|js)(\?.*)?$") { unset beresp.http.set-cookie; } # Allow items to be stale if needed. set beresp.grace = 6h; } # In the event of an error, show friendlier messages. sub vcl_error { # Redirect to some other URL in the case of a homepage failure. #if (req.url ~ "^/?$") { # set obj.status = 302; # set obj.http.Location = "http://backup.example.com/"; #} # Otherwise redirect to the homepage, which will likely be in the cache. set obj.http.Content-Type = "text/html; charset=utf-8"; synthetic {" <html> <head> <title>Page Unavailable</title> <style> body { background: #303030; text-align: center; color: white; } #page { border: 1px solid #CCC; width: 500px; margin: 100px auto 0; padding: 30px; background: #323232; } a, a:link, a:visited { color: #CCC; } .error { color: #222; } </style> </head> <body onload="setTimeout(function() { window.location = '/' }, 5000)"> <div id="page"> <h1 class="title">Page Unavailable</h1> <p>The page you requested is temporarily unavailable.</p> <p>We're redirecting you to the <a href="/">homepage</a> in 5 seconds.</p> <div class="error">(Error "} + obj.status + " " + obj.response + {")</div> </div> </body> </html> "}; return (deliver); } I'm getting a MISS and age 0 every time. If I'm understanding correctly, this means the file isn't being returned from Varnish's cache. Is there a problem with my Varnish config?

    Read the article

  • How to best config my PC. 2 small SDDs and a 1TB conventional drive

    - by Chadworthington
    I just got a new PC. It has 3 drives C Drive: 80GB SDD Drive P Drive: 120GB SDD (for core programs) D Drive: 1TB SDD (for data and other) I have an MSDN subscription and I am the type of person that loves to install tons of software to check it out. I am very worried that installation programs are forcing me to place a large amount of files on the small C drive. I fear that I will quickly run out of space on my C drive while having ample space on my TB drive. What would you do in my shoes? I didn't select this PC or set the config up. I am wishing that the 120 SSD was my C, to give me a little more room to grow. I guess there are no magic solutions here but I am just looking for your general thoughts

    Read the article

  • cdrom drive doesn't work on laptop

    - by bozdoz
    Here's as best as I can describe it: When starting up, the boot order doesn't recognize the cdrom drive, but I can open and close the drive during this time. In Windows 7, I can't open the cdrom drive, and it doesn't recognize it in device manager, disk management, or my computer. In Ubuntu Linux, I can open the cdrom drive, but it still doesn't recognize the cds, and it won't mount. If I reformat everything, would my cdrom drive work again? Can I reinstall Windows without a cdrom drive? I've deleted the upper and lower filters as was suggested in Google searches. Took the disk drive out and checked that it was installed correctly (no reason it shouldn't have been). Still: nothing works.

    Read the article

  • Limit size of cache directory.

    - by M.A. Cape
    I have some questions about the cache directory in android. Does anyone knows the limit for each app's cache directory? Also what will happen if there is not enough disk space to cache data? All I know is when the device runs low on storage, the files here (cache directory)will be the ones that get deleted first and each app has its own cache directory. Now, are the files of other app's cache directory will be cleared to accommodate my app's request to add files in the cache dir when there is not enough storage?

    Read the article

  • Are there any nasty side affects if i lock the HttpContext.Current.Cache.Insert method

    - by Ekk
    Apart from blocking other threads reading from the cache what other problems should I be thinking about when locking the cache insert method for a public facing website. The actual data retrieval and insert into the cache should take no more than 1 second, which we can live with. More importantly i don't want multiple thread potentially all hitting the Insert method at the same time. The sample code looks something like: public static readonly object _syncRoot = new object(); if (HttpContext.Current.Cache["key"] == null) { lock (_syncRoot) { HttpContext.Current.Cache.Insert("key", "DATA", null, DateTime.Now.AddMinutes(5), Cache.NoSlidingExpiration, CacheItemPriority.Normal, null); } } Response.Write(HttpContext.Current.Cache["key"]);

    Read the article

  • Strategies for generating Zend Cache Keys

    - by emeraldjava
    ATM i'm manually generating a cache key based on the method name and parameters, then follow to the normal cache pattern. This is all done in the Controller and i'm calling a model class that 'extends Zend_Db_Table_Abstract'. public function indexAction() { $cache = Zend_Registry::get('cache'); $individualleaguekey = sprintf("getIndividualLeague_%d_%s",$leagueid,$division->code); if(!$leaguetable = $cache->load($individualleaguekey)) { $table = new Model_DbTable_Raceresult(); $leaguetable = $table->getIndividualLeague($leagueid,$division,$races); $cache->save($leaguetable, $individualleaguekey); } $this->view->leaguetable = $leaguetable; .... I want to avoid the duplication of parameters to the cache creation method and also to the model method, so i'm thinking of moving the caching logic away from my controller class and into model class packaged in './model/DbTable', but this seems incorrect since the DB model should only handle SQL operations. Any suggestions on how i can implement a clean patterned solution?

    Read the article

  • What is safe to exclude for a full system backup?

    - by seb
    Hi, I'm looking for a list which paths/files are safe to exclude for a full system/home backup. Considering that I have a list of installed packages. /home/*/.thumbnails /home/*/.cache /home/*/.mozilla/firefox/*.default/Cache /home/*/.mozilla/firefox/*.default/OfflineCache /home/*/.local/share/Trash /home/*/.gvfs/ /tmp/ /var/tmp/ not real folders but can cause severe problems when 'restoring' /dev /proc /sys What about... /var/ in general? /var/backups/ - can get quite large /var/log/ - does not require much space and can help for later comparison /lost+found/

    Read the article

  • MINSCN?Cache Fusion Read Consistent

    - by Liu Maclean(???)
    ????? ???Ask Maclean Home ???  RAC ? Past Image PI????, ?????????,???11.2.0.3 2 Node RAC??????????: SQL> select * from v$version; BANNER -------------------------------------------------------------------------------- Oracle Database 11g Enterprise Edition Release 11.2.0.3.0 - 64bit Production PL/SQL Release 11.2.0.3.0 - Production CORE 11.2.0.3.0 Production TNS for Linux: Version 11.2.0.3.0 - Production NLSRTL Version 11.2.0.3.0 - Production SQL> select * from global_name; GLOBAL_NAME -------------------------------------------------------------------------------- www.oracledatabase12g.com SQL> drop table test purge; Table dropped. SQL> alter system flush buffer_cache; System altered. SQL> create table test(id number); insert into test values(1); insert into test values(2); commit; /* ???? rowid??TEST????2????????? */ select dbms_rowid.rowid_block_number(rowid),dbms_rowid.rowid_relative_fno(rowid) from test; DBMS_ROWID.ROWID_BLOCK_NUMBER(ROWID) DBMS_ROWID.ROWID_RELATIVE_FNO(ROWID) ------------------------------------ ------------------------------------                                89233                                    1                                89233                                    1 SQL> alter system flush buffer_cache; System altered. Instance 1 Session A ??UPDATE??: SQL> update test set id=id+1 where id=1; 1 row updated. Instance 1 Session B ??x$BH buffer header?? ?? ??Buffer??? SQL> select state,cr_scn_bas from x$bh where file#=1 and dbablk=89233 and state!=0;      STATE CR_SCN_BAS ---------- ----------          1          0          3    1227595 X$BH ??? STATE????Buffer???, ???????: STATE NUMBER KCBBHFREE 0 buffer free KCBBHEXLCUR 1 buffer current (and if DFS locked X) KCBBHSHRCUR 2 buffer current (and if DFS locked S) KCBBHCR 3 buffer consistant read KCBBHREADING 4 Being read KCBBHMRECOVERY 5 media recovery (current & special) KCBBHIRECOVERY 6 Instance recovery (somewhat special) ????????????? : state =1 Xcurrent ? state=2 Scurrent ? state=3 CR ??? Instance 2  ?? ????????????? ,???? gc current block 2 way  ??Current Block ??? Instance 2, ?? Instance 1 ??”Current Block” Convert ? Past Image: Instance 2 Session C SQL> update test set id=id+1 where id=2; 1 row updated. Instance 2 Session D SQL> select state,cr_scn_bas from x$bh where file#=1 and dbablk=89233 and state!=0; STATE CR_SCN_BAS ---------- ---------- 1 0 3 1227641 3 1227638 STATE =1 ?Xcurrent block???? Instance 2 , ??? Instance 1 ??? GC??: Instance 1 Session B SQL> select state,cr_scn_bas from x$bh where file#=1 and dbablk=89233 and state!=0;      STATE CR_SCN_BAS ---------- ----------          3    1227641          3    1227638          8          0          3    1227595 ???????, ??????Instance 1??session A????TEST??SELECT??? ,????? 3? State=3?CR ? ??????1?: Instance 1 session A ?????UPDATE? session SQL> alter session set events '10046 trace name context forever,level 8:10708 trace name context forever,level 103: trace[rac.*] disk high'; Session altered. SQL> select * from test;         ID ----------          2          2 select state,cr_scn_bas from x$bh where file#=1 and dbablk=89233 and state!=0;       STATE CR_SCN_BAS ---------- ----------          3    1227716          3    1227713          8          0 ?????????v$BH ????CR????,?????SELECT??? CR????????,???????? ?????????? ??X$BH?????? , ?????CR??SCN Version???: 1227641?1227638?1227595, ?SELECT?????? 2???SCN version?CR? 1227716? 1227713 ???, Oracle????????? ?????????SELECT??????event 10708? rac.*???TRACE,??????TRACE??: PARSING IN CURSOR #140444679938584 len=337 dep=1 uid=0 oct=3 lid=0 tim=1335698913632292 hv=3345277572 ad='bc0e68c8' sqlid='baj7tjm3q9sn4' SELECT /* OPT_DYN_SAMP */ /*+ ALL_ROWS IGNORE_WHERE_CLAUSE NO_PARALLEL(SAMPLESUB) opt_param('parallel_execution_enabled', 'false') NO_PARALLEL_INDEX(SAMPLESUB) NO_SQL_TUNE */ NVL(SUM(C1),0), NVL(SUM(C2),0) FROM (SELECT /*+ NO_PARALLEL("TEST") FULL("TEST") NO_PARALLEL_INDEX("TEST") */ 1 AS C1, 1 AS C2 FROM "SYS"."TEST" "TEST") SAMPLESUB END OF STMT PARSE #140444679938584:c=1000,e=27630,p=0,cr=0,cu=0,mis=1,r=0,dep=1,og=1,plh=1950795681,tim=1335698913632252 EXEC #140444679938584:c=0,e=44,p=0,cr=0,cu=0,mis=0,r=0,dep=1,og=1,plh=1950795681,tim=1335698913632390 *** 2012-04-29 07:28:33.632 kclscrs: req=0 block=1/89233 *** 2012-04-29 07:28:33.632 kclscrs: bid=1:3:1:0:7:80:1:0:4:0:0:0:1:2:4:1:26:0:0:0:70:1a:0:0:0:0:0:0:0:0:0:0:0:0:0:0:0:0:0:0:4:3:2:1:2:0:3f:0:1c:86:2d:4:0:0:0:0:a2:3c:7c:b:70:1a:0:0:0:0:1:0:7a:f8:76:1d:1:2:dc:5:a9:fe:17:75:0:0:0:0:0:0:0:0:0:0:0:0:63:e5:0:0:0:0:0:0:10:0:0:0 2012-04-29 07:28:33.632578 : kjbcrc[0x15c91.1 76896.0][9] 2012-04-29 07:28:33.632616 : GSIPC:GMBQ: buff 0xba1e8f90, queue 0xbb79f278, pool 0x60013fa0, freeq 1, nxt 0xbb79f278, prv 0xbb79f278 2012-04-29 07:28:33.632634 : kjbmscrc(0x15c91.1)seq 0x2 reqid=0x1c(shadow 0xb4bb4458,reqid x1c)mas@2(infosz 200)(direct 1) 2012-04-29 07:28:33.632654 : kjbsentscn[0x0.12bbc1][to 2] 2012-04-29 07:28:33.632669 : GSIPC:SENDM: send msg 0xba1e9000 dest x20001 seq 24026 type 32 tkts xff0000 mlen x17001a0 2012-04-29 07:28:33.633385 : GSIPC:KSXPCB: msg 0xba1e9000 status 30, type 32, dest 2, rcvr 1 *** 2012-04-29 07:28:33.633 kclwcrs: wait=0 tm=689 *** 2012-04-29 07:28:33.633 kclwcrs: got 1 blocks from ksxprcv WAIT #140444679938584: nam='gc cr block 2-way' ela= 689 p1=1 p2=89233 p3=1 obj#=76896 tim=1335698913633418 2012-04-29 07:28:33.633490 : kjbcrcomplete[0x15c91.1 76896.0][0] 2012-04-29 07:28:33.633510 : kjbrcvdscn[0x0.12bbc1][from 2][idx 2012-04-29 07:28:33.633527 : kjbrcvdscn[no bscn <= rscn 0x0.12bbc1][from 2] *** 2012-04-29 07:28:33.633 kclwcrs: req=0 typ=cr(2) wtyp=2hop tm=689 ??TRACE???? ?????????TEST??????, ???????Dynamic Sampling?????,???????TEST?? CR???,???????’gc cr block 2-way’ ??: 2012-04-29 07:28:33.632654 : kjbsentscn[0x0.12bbc1][to 2] 12bbc1= 1227713  ???X$BH????CR???,kjbsentscn[0x0.12bbc1][to 2] ????? ? Instance 2 ???SCN=12bbc1=1227713   DBA=0x15c91.1 76896.0 ?  CR Request(obj#=76896) ??kjbrcvdscn????? [no bscn <= rscn 0x0.12bbc1][from 2] ,??? ??receive? SCN Version =12bbc1 ???Best Version CR Server Arch ??????????????????SELECT??: PARSING IN CURSOR #140444682869592 len=18 dep=0 uid=0 oct=3 lid=0 tim=1335698913635874 hv=1689401402 ad='b1a188f0' sqlid='c99yw1xkb4f1u' select * from test END OF STMT PARSE #140444682869592:c=4999,e=34017,p=0,cr=7,cu=0,mis=1,r=0,dep=0,og=1,plh=1357081020,tim=1335698913635870 EXEC #140444682869592:c=0,e=23,p=0,cr=0,cu=0,mis=0,r=0,dep=0,og=1,plh=1357081020,tim=1335698913635939 WAIT #140444682869592: nam='SQL*Net message to client' ela= 7 driver id=1650815232 #bytes=1 p3=0 obj#=0 tim=1335698913636071 *** 2012-04-29 07:28:33.636 kclscrs: req=0 block=1/89233 *** 2012-04-29 07:28:33.636 kclscrs: bid=1:3:1:0:7:83:1:0:4:0:0:0:1:2:4:1:26:0:0:0:70:1a:0:0:0:0:0:0:0:0:0:0:0:0:0:0:0:0:0:0:4:3:2:1:2:0:2:0:1c:86:2d:4:0:0:0:0:a2:3c:7c:b:70:1a:0:0:0:0:1:0:7d:f8:76:1d:1:2:dc:5:a9:fe:17:75:0:0:0:0:0:0:0:0:0:0:0:0:63:e5:0:0:0:0:0:0:10:0:0:0 2012-04-29 07:28:33.636209 : kjbcrc[0x15c91.1 76896.0][9] 2012-04-29 07:28:33.636228 : GSIPC:GMBQ: buff 0xba0e5d50, queue 0xbb79f278, pool 0x60013fa0, freeq 1, nxt 0xbb79f278, prv 0xbb79f278 2012-04-29 07:28:33.636244 : kjbmscrc(0x15c91.1)seq 0x3 reqid=0x1d(shadow 0xb4bb4458,reqid x1d)mas@2(infosz 200)(direct 1) 2012-04-29 07:28:33.636252 : kjbsentscn[0x0.12bbc4][to 2] 2012-04-29 07:28:33.636358 : GSIPC:SENDM: send msg 0xba0e5dc0 dest x20001 seq 24029 type 32 tkts xff0000 mlen x17001a0 2012-04-29 07:28:33.636861 : GSIPC:KSXPCB: msg 0xba0e5dc0 status 30, type 32, dest 2, rcvr 1 *** 2012-04-29 07:28:33.637 kclwcrs: wait=0 tm=865 *** 2012-04-29 07:28:33.637 kclwcrs: got 1 blocks from ksxprcv WAIT #140444682869592: nam='gc cr block 2-way' ela= 865 p1=1 p2=89233 p3=1 obj#=76896 tim=1335698913637294 2012-04-29 07:28:33.637356 : kjbcrcomplete[0x15c91.1 76896.0][0] 2012-04-29 07:28:33.637374 : kjbrcvdscn[0x0.12bbc4][from 2][idx 2012-04-29 07:28:33.637389 : kjbrcvdscn[no bscn <= rscn 0x0.12bbc4][from 2] *** 2012-04-29 07:28:33.637 kclwcrs: req=0 typ=cr(2) wtyp=2hop tm=865 ???, “SELECT * FROM TEST”??????’gc cr block 2-way’??:2012-04-29 07:28:33.637374 : kjbrcvdscn[0x0.12bbc4][from 2][idx 2012-04-29 07:28:33.637389 : kjbrcvdscn[no bscn ??Foreground Process? Remote LMS??got?? SCN=1227716 Version?CR, ??? ?????X$BH ?????scn??? ??????????Instance 1????2?SCN???CR?, ???????????Instance 1 Buffer Cache?? ??SCN Version ???CR ??????? ?????????: SQL> alter system set "_enable_minscn_cr"=false scope=spfile; System altered. SQL> alter system set "_db_block_max_cr_dba"=20 scope=spfile; System altered. SQL> startup force; ORA-32004: obsolete or deprecated parameter(s) specified for RDBMS instance ORACLE instance started. Total System Global Area 1570009088 bytes Fixed Size 2228704 bytes Variable Size 989859360 bytes Database Buffers 570425344 bytes Redo Buffers 7495680 bytes Database mounted. Database opened. ???? “_enable_minscn_cr”=false ? “_db_block_max_cr_dba”=20 ???RAC????, ??????: ?Instance 2 Session C ?update??????? ?????Instance 1 ????? ,????Instance 1?Request CR SQL> update test set id=id+1 where id=2; -- Instance 2 1 row updated. SQL> select * From test; -- Instance 1 ID ---------- 1 2 ??? Instance 1? X$BH?? select state,cr_scn_bas from x$bh where file#=1 and dbablk=89233 and state!=0;  STATE CR_SCN_BAS ---------- ---------- 3 1273080 3 1273071 3 1273041 3 1273039 8 0 SQL> update test set id=id+1 where id=3; 1 row updated. SQL> select * From test; ID ---------- 1 2 SQL> select state,cr_scn_bas from x$bh where file#=1 and dbablk=89233 and state!=0; STATE CR_SCN_BAS ---------- ---------- 3 1273091 3 1273080 3 1273071 3 1273041 3 1273039 8 0 ................... SQL> select state,cr_scn_bas from x$bh where file#=1 and dbablk=89233 and state!=0; STATE CR_SCN_BAS ---------- ---------- 3 1273793 3 1273782 3 1273780 3 1273769 3 1273734 3 1273715 3 1273691 3 1273679 3 1273670 3 1273643 3 1273635 3 1273623 3 1273106 3 1273091 3 1273080 3 1273071 3 1273041 3 1273039 3 1273033 19 rows selected. SQL> select state,cr_scn_bas from x$bh where file#=1 and dbablk=89233 and state!=0; STATE CR_SCN_BAS ---------- ---------- 3 1274993 ????? ???? “_enable_minscn_cr”(enable/disable minscn optimization for CR)=false ? “_db_block_max_cr_dba”=20 (Maximum Allowed Number of CR buffers per dba) 2? ??? ????? Instance 1 ??????????? ?? 19????CR?? “_enable_minscn_cr”?11g??????????,???Oracle????CR????SCN,?Foreground Process Receive????????????(SCN??)?SCN Version CR Block??????CBC?? SCN??????CR? , ?????????Buffer Cache??????? ????SCN Version?CR????,????? ?????????? ?????Snap_Scn ?? SCN?? ?????????Current SCN, ??????CR??????????????????????, ????Buffer Cache? ?????????? CR?????????, ?????? “_db_block_max_cr_dba” ???????, ???????????20 ,??????Buffer Cache?????19????CR?; ???”_db_block_max_cr_dba” ???????6 , ?????Buffer cache????????CR ???????6?? ??”_enable_minscn_cr” ??CR???MINSCN ??????, ?????????CR???????, ????? Foreground Process??????CR Request , ?? Holder Instance LMS ?build?? BEST CR ??, ?????????

    Read the article

  • "No caching mode page present" when USB flash disk attached

    - by evgeny9
    When attaching a USB flash disk (NTFS formatted) to a laptop with Ubuntu Server 12.04 on board, I get following messages: [ 3572.355603] sd 2:0:0:0: [sdb] No Caching mode page present [ 3572.355640] sd 2:0:0:0: [sdb] Assuming drive cache: write through [ 3572.361599] sd 2:0:0:0: [sdb] No Caching mode page present [ 3572.361636] sd 2:0:0:0: [sdb] Assuming drive cache: write through I get them right in the terminal, so that I should press Ctrl+C to proceed with working (entering commands). Is it normal or do I have to setup Caching mode somehow? Thank you.

    Read the article

  • ???????????I/O?SSD????!

    - by Yusuke.Yamamoto
    ????? ??:2010/11/25 ??:???? ?????????????????????I/O???????????????? Oracle Database 11g Release 2 ?????Database Smart Flash Cache?????????????????????????????????????????????????????? ???????????????????SSD????????????"?????(??)"???????????????????? Database Smart Flash Cache ???OLTP??+?????????????????OLTP??+OLTP???10????????? ????????? ????????????????? http://oracletech.jp/products/pickup/000076.html

    Read the article

  • Is my HDD dead forever?

    - by Roberto
    Yesterday I turned on my computer and it couldn't boot. I found out the hd (320GB SATA Seagate Momentus 7200.3 for notebook) was broken and it couldn't be recognized by the BIOS. I have another of the same hard drive, so I exchanged the boards. I found out that there is a problem on its board since my good hard drive didn't work. But the broken hard drive doesn't work with the good board as well: it can be recognized but when I insert a Windows Instalation DVD it says the hard drive is 0GB. I put it in a case and use it in another computer via USB, and but it doesn't show up in the "My Computer". I used a software to recover files called "GetDataBack for NTFS", it recognized the hard drive but with the wrong size (2TB). I try to make it read the hard drive but it got an I/O error reading sector. It tries to read, the hard drive spins up. So, since I'm using a good board on it, the problem seems to be internal. Is there anything someone could do to recover the files from it?

    Read the article

  • Windows 7 - "A disk read error occured. Press Ctrl + Alt + Del to restart"

    - by Senthil
    Problem: When I switch on my PC, after BIOS POST, a cursor is blinking for about 5 seconds and then I am getting this error message: A disk read error occurred. Press Ctrl + Alt + Del to restart. I am able to go into BIOS. But Windows loader doesn't even start. This message is shown after my motherboard logo comes and goes. Symptoms: I DID notice my system freezing for minutes at a time for past two days. Also, in the past two days, it stopped half way through the Window booting process. I had to do hard reset couple of times to get it working. But since today morning, I only get this error message. Configuration: Operating System: Windows 7 Ultimate 32-bit only. Hard disk: 1 Physical Disk - 80GB SATA Partitions: Two (2) - C: and D: File System: NTFS No drive encryption or compression is turned on. After I searched on the net, I have found people mentioning these possible causes: Hard Disk is physically failing Corrupt MBR Bad Sector I am planning to buy a new hard disk, install Windows on it and continue. But I need data from the old hard disk. The data I want is in D: drive, outside any Windows user folder, is not encrypted or compressed or protected in anyway. I think if someone/something can get the disk working again and knows NTFS, the data can be hopefully read. What steps should I follow to recover files from the defective disk? Update: I bought a new disk, installed windows on it and added the defective one as a slave. Then I was able to read the data from the defective hard disk. Though chkdsk found lots of errors, the files I wanted were not affected and I got them back :) I am not using that hard disk anymore though it seems to be working at the moment.

    Read the article

  • How do I fix a corrupt calendar cache?

    - by Blacklight Shining
    I was tailing /var/log/system.log and noticed a sudden wall of text. Looking closer, I saw it was an error CalendarAgent got while trying to save something: Nov 18 11:42:45 rainbow-dash.local CalendarAgent[12321]: CoreData: error: (11) Fatal error. The database at /Users/blackl/Library/Calendars/Calendar Cache is corrupted. SQLite error code:11, 'database disk image is malformed' Nov 18 11:42:45 rainbow-dash.local CalendarAgent[12321]: Core Data: annotation: -executeRequest: encountered exception = Fatal error. The database at /Users/blackl/Library/Calendars/Calendar Cache is corrupted. SQLite error code:11, 'database disk image is malformed' with userInfo = { NSFilePath = "/Users/blackl/Library/Calendars/Calendar Cache"; NSSQLiteErrorDomain = 11; } 2 messages repeated several times Nov 18 11:42:49 rainbow-dash.local CalendarAgent[12321]: [com.apple.calendar.store.log.subscription] [WARNING: CalSubscriptionSession :: persistError :: save failed] This entire sequence is repeated many times throughout the log. file said the file in question was a SQLite 3.x database, so I did a bit of searching and came up with a way to check those. blackl% cp -i ~/Library/Calendars/Calendar\ Cache /tmp blackl% sqlite3 /tmp/Calendar\ Cache SQLite version 3.7.12 2012-04-03 19:43:07 Enter ".help" for instructions Enter SQL statements terminated with a ";" sqlite> pragma integrity_check ; *** in database main *** Main freelist: Bad ptr map entry key=863 expected=(2,0) got=(5,21) On page 21 at right child: 2nd reference to page 863 This is followed by a few dozen lines like these: rowid <number> missing from index <name> and then: wrong # of entries in index <name> I'm at a bit of a loss as to what to do now—I couldn't find anything on how to fix the errors that I found. Also, it would probably be a good idea to disable Calendar Agent so it doesn't try to use the database while it's being fixed (that's why I copied it to /tmp before running sqlite3 on it.) How do I disable CalendarAgent and fix its cache?

    Read the article

  • How do hdparm's -S and -B options interact?

    - by user697683
    These two options seem confusing. For example: according to the man page -B 254 "does not permit spin-down". However, testing with -B 254 -S 1 the drive does spin down after 5 seconds. -B Query/set Advanced Power Management feature, if the drive supports it. A low value means aggressive power management and a high value means better performance. Possible settings range from values 1 through 127 (which permit spin-down), and values 128 through 254 (which do not permit spin-down). The highest degree of power management is attained with a setting of 1, and the highest I/O performance with a setting of 254. A value of 255 tells hdparm to disable Advanced Power Management altogether on the drive (not all drives support disabling it, but most do). -S Put the drive into idle (low-power) mode, and also set the standby (spindown) timeout for the drive. This timeout value is used by the drive to determine how long to wait (with no disk activity) before turning off the spindle motor to save power. Under such circumstances, the drive may take as long as 30 seconds to respond to a subsequent disk access, though most drives are much quicker. The encoding of the timeout value is somewhat peculiar. A value of zero means "timeouts are disabled": the device will not automatically enter standby mode. Values from 1 to 240 specify multiples of 5 seconds, yielding timeouts from 5 seconds to 20 minutes. Values from 241 to 251 specify from 1 to 11 units of 30 minutes, yielding timeouts from 30 minutes to 5.5 hours. A value of 252 signifies a timeout of 21 minutes. A value of 253 sets a vendor-defined timeout period between 8 and 12 hours, and the value 254 is reserved. 255 is interpreted as 21 minutes plus 15 seconds. Note that some older drives may have very different interpretations of these values.

    Read the article

  • Windows 7 Install: No drives were found

    - by Albert Bori
    I was building a computer for my wife with an older SATA hard drive that I had lying around, and when attempting to do a new install of Windows 7 on it, the installer says: "No drives were found. Click Load Driver to provide a mass storage driver for installation." I ran the diskpart command: list volume, and it showed up as "Raw". So, I formatted it to NTFS and then it showed up as a healthy drive in diskpart. I also ran check disk on it with no errors. Windows 7 installer STILL can't find the drive. As far as BIOS settings, I have tried "Native IDE", AHCI, and Both AHCI/IDE mode (SATA slots 0-2 AHCI, 3-4 IDE). I tried all combinations... still "no drives were found". At this point, I'm just scratching my head. Using the installation dos window, I can see and talk to the drive just fine, but the installer just doesn't see it at all. I've even written folders and files to the drive, and it still "can't be seen". Any help would be great. Items of interest: Motherboard model: Gigabyte GA-A75M-UD2H - BIOS Version F5 (latest) Hard drive model: 80GB Seagate Barracuda 7200.7 ST380817AS (no other drives) Installing Windows 7 using a FAT32 formatted USB Drive, which I've used for other installs

    Read the article

  • Fixing Windows install by connecting it's hard drive via USB to a different laptop

    - by Jason
    I tried to upgrade a laptop to SP3, which broke it. I later found out SP3 doesn't work on that 2002 laptop. I can't uninstall SP3, or fix SP2, because the hard drive is now not detected during setup (I've read that's the problem you get). I put the hard drive in a USB drive case and plugged it into my other laptop, and I can read (& write to) the disk okay. (The hard drive won't fit in my other laptop, so I'm using USB.) I need to get that disk back to SP2, or fix whatever files got screwed up causing the disk to not be recognized. I don't want to do a re-install as there are 80GB of files on it I need, and they won't fit on the HD of my other laptop, and also because I no longer have some of the install CDs for software on it. What do I need to do to fix that drive from my other laptop? (I don't want my working laptop (XP SP3) to get screwed with by putting an SP2 disk in the CD drive, or the non-o/s data on the other hard drive screwed with.)

    Read the article

  • Fixing Windows install by connecting its hard drive via USB to a different laptop

    - by Jason
    I tried to upgrade a laptop to SP3, which broke it. I later found out SP3 doesn't work on that 2002 laptop. I can't uninstall SP3, or fix SP2, because the hard drive is now not detected during setup (I've read that's the problem you get). I put the hard drive in a USB drive case and plugged it into my other laptop, and I can read (& write to) the disk okay. (The hard drive won't fit in my other laptop, so I'm using USB.) I need to get that disk back to SP2, or fix whatever files got screwed up causing the disk to not be recognized. I don't want to do a re-install as there are 80GB of files on it I need, and they won't fit on the HD of my other laptop, and also because I no longer have some of the install CDs for software on it. What do I need to do to fix that drive from my other laptop? (I don't want my working laptop (XP SP3) to get screwed with by putting an SP2 disk in the CD drive, or the non-o/s data on the other hard drive screwed with.)

    Read the article

  • What is the best practice to cache images on Android?

    - by barmaleikin
    Hi guys, In my application I use SoftReference to cache images, it is working fine with active internet connection. And now I need to cache images, so I could use it in offline mode. What is the best way to implement it? Use complex solution with SoftReference and database? or maybe SoftReference and local storage (sdcard)? I would appreciate your advices. Thanks.

    Read the article

  • Can the .NET MethodInfo cache be cleared or disabled?

    - by Anton
    Per MSDN, calling Type.GetMethods() stores reflected method information in a MemberInfo cache so the expensive operation doesn't have to be performed again. I have an application that scans assemblies/types, looking for methods that match a given specification. The problem is that memory consumption increases significantly (especially with large numbers of referenced assemblies) since .NET hangs onto the method metadata. Is there any way to clear or disable this MemberInfo cache?

    Read the article

< Previous Page | 63 64 65 66 67 68 69 70 71 72 73 74  | Next Page >