Search Results

Search found 2565 results on 103 pages for 'sys'.

Page 67/103 | < Previous Page | 63 64 65 66 67 68 69 70 71 72 73 74  | Next Page >

  • Why do I see different TCP behaviour between IIS and FTP server applications on Windows 2003?

    - by rupello
    I am comparing Wireshark traces of a 10MB file download file from: the FileZilla FTP server and IIS (using HTTP) on the same Windows 2003 server. The FTP download performs faster and the trace shows the server behaving as expected, sending more data to the client with every ACK received: Link to full-size image The HTTP server trace shows a more bursty pattern. The timing of the send bursts are sometimes unrelated to any ACKs received from the client (circled in red): Link to full-size image Anyone have a suggestion as to why IIS traffic is having like this? Update: We have tried modifying the http.sys registry settings (setting MaxBytesPerSend to 256k and MaxBufferedSendBytes to 64k as recommended). Changing MaxBytesPerSend does seem to improve performance by increasing the amount of in-flight data , but we still see the same bursty pattern.

    Read the article

  • How feasible is it to setup a FreeNAS to be more like a full install of FreeBSD

    - by mmccoo
    So I've been playing with FreeNAS over the last week, finally trying to get my act together and store my important files properly. I'm finding myself wanting to install and compile additional packages. pkg_add has been great for some things, but it appears that my install is rather crippled. make is missing. I installed gmake and linked make to that. math.h is missing as is sys/cdefs.h I thought these are part of any core unix/linux system? cc is missing though I've installed gcc45. I'm used to having just gcc. Sure I can create a link, but I'm not sure this is the proper thing to do. perl installed fine, but I can't add stuff with cpan. This is how I discovered 1,2, and 3. So my question is this: do I just need to bite the bullet and install a full FreeBSD? The web interface to FreeNAS is kinda nice

    Read the article

  • Why my USB mouse get suspended after 3 seconds of inactivity?

    - by Vi.
    Mouse's bottom LED goes off after 3 seconds after connection and cursor movements and wheel stops. Pressing any button, reconnecting or resetting USB device resumes it for another 3 seconds (when resumed by pressing button, this event does no go to X). This happens when using any of USB ports. This mouse works well with other computer with Linux. It was working well before. Why can it happen? How to fix it? Update: It happens only if laptop is on battery. Answer: this is caused by powersaving done by laptop-mode-tools. To temporary turn off powersaving one can use for i in /sys/bus/usb/devices/*/power/control; do echo on > $i; done

    Read the article

  • Dropping Cached Memory on FreeBSD

    - by user1066698
    i use FreeNAS server which is built on OS version FreeBSD 8.2-RELEASE-p6. I use ZFS file system with 13TB HDD on my 8GB physical ram installed box. It almost uses all of RAM installed while proccessing some request. However, it still uses same amount of memory on idle times. So this is becoming a problem sometimes. On my centos web server; i use following command to drop cached memory with a cronjob; sync; echo 3 > /proc/sys/vm/drop_caches However, this command does not work on my Freenas server. How can i drop cached memory on my FreeNAS box which is built on FreeBSD 8.2 Thank you

    Read the article

  • Testifying that somaxconn change can make a difference

    - by petermolnar
    I got into an argument on the net.core.somaxconn parameter: I was told that it will not make any difference if we change the default 128. I believed this might be enough proof: "If the backlog argument is greater than the value in /proc/sys/net/core/somaxconn, then it is silently truncated to that value" http://linux.die.net/man/2/listen but it's not. So does anyone know a method to testify this with two machines, one running, for example MySQL or LVS and the other is hammering it in a GBit network? I'm opened to any solution, scripts are slightly more welcome.

    Read the article

  • Is there a way to change the permissions of a series of directories on Windows 7 without getting a dialog box when it can't change the rights?

    - by leeand00
    Is there some way to change the permissions recursively on a series of directories without getting a dialog box that pops up and tells me it can't change the permissions on a particular file? I keep getting this dialogs multiple times duing the process of changing permissions: An error occurred while applying security information to: C:\pagefile.sys The process cannot access the file because it is being used another process. Eventually I get so many of them that I start clicking the mouse or pressing the space bar so many times that I accidentally click the cancel button. Also it would be great if I could keep a log of which files it can't change permissions on. Is this possible in Windows 7? Does it have to be done from the command prompt or from powershell?

    Read the article

  • Disabling the shell of user "daemon" (/bin/false)

    - by BurninLeo
    on a Linux system there are lot's of users by default: daemon, bin, sys, games, etc. According to my /etc/passwd most of these users have a shell assigned (/bin/sh) which seems some kind of insecure to me. My naive thinking would say: Only give those users a shell that may login to the server. Is my thinking wrong? If not completely wrong: Can I disable the shell for "daemon" and "www-data" without having side effects (e.g. the system wont start or the Apache PHP cannot excute system calls)? Thanks for your hints!

    Read the article

  • PPTP VPN Server issue : server = centOS & client = windows 7

    - by jmassic
    I have a CentOS server configured as a PPTP VPN Server. The client is a Windows 7 with "Use default gateway on remote network" in advanced TCP/IPv4 properties enable. He can connect to CentOS without any problem and can access to: The Box of his ISP (http://192.168.1.254/) The CentOS server The website which is hosted by the server (through http://) But he canNOT access any other web service (google.com or 74.125.230.224) I am a beginner with web servers so I do not know what can cause this problem. Note 0 : The Windows 7 user must be able to access the whole internet through the CentOS PPTP proxy. Note 1 : With "Use default gateway on remote network" in advanced TCP/IPv4 UNCHECKED it is the same problem Note 2 : With "Use default gateway on remote network" in advanced TCP/IPv4 UNCHECKED AND "disable class based route addition" CHECKED the Win 7 can access google but with the ISP IP (no use of the VPN...) See Screenshot Note 3 : I have made a echo 1 > /proc/sys/net/ipv4/ip_forward and a iptables -t nat -A POSTROUTING -o eth0 -j MASQUERADE

    Read the article

  • EC2 Windows 2008 VM import Not Working

    - by remack
    I am trying to upload a Windows 2008 SP2 server image to Amazon EC2, but once the process is complete, I can't connect to it. I had ops export a VMDK from our datacenter. The image appeared to have a fixed IP, so I loaded it in VMWare player and enabled DHCP. I uploaded it following amazon's instructions: http://aws.amazon.com/ec2/vmimport/ I start the new instance and try to RDP to the public DNS; connection fails. My two thoughts are: Loading it in VMWare player messed it up somehow, since the instructions say use an ESX image. The image they made me had the wrong network adapter type. The image has an Intel(R) PRO/1000 MT adapter using the E1G60I32.sys driver.

    Read the article

  • HP Presario CQ 61-322ER (VV884EA) Wi-Fi hang up! [closed]

    - by qgrabber
    Possible Duplicate: HP Presario CQ 61-322ER (VV884EA) Wi-Fi hang up! I have my new laptop and don't have Windows XP drivers for it. I found that it contains the Broadcom BCM4310 chip, but when I install any Broadcom driver my laptop hangup on installing bcm5*.sys driver. Only power-off button make any effect. After reboot the device list (Device Manager) contains Broadcom WLAN adapter, but it is marked as disabled, for some hardware errror! Also if I disable device before, and install driver - then - all is OK! But when I try to enable it, Windows hang up anyway (no speaker beep, no mouse input, no keyboard input - nothing) What is the solution?

    Read the article

  • What is the equivalent of domain admin on Sharepoint 2010?

    - by user54266
    I have to support Sharepoint on a daily basis but do not have the equivalent of domain access so I'm constantly having to ask the guy in charge of Sharepoint to add me to a new security group to complete my task. Rather than having to bug him all the time (he is only somewhat technical) it would be easier to simply have the equivalent of domain admin access for Sharepoint (I'm a sys admin and have domain admin access already but this doesn't seem to carry over to FOSS). What is the equivalent of domain admin access on Sharepoint 2010? Thanks in advance.

    Read the article

  • Need help with setting up comet code

    - by Saif Bechan
    Does anyone know off a way or maybe think its possible to connect Node.js with Nginx http push module to maintain a persistent connection between client and browser. I am new to comet so just don't understand the publishing etc maybe someone can help me with this. What i have set up so far is the following. I downloaded the jQuery.comet plugin and set up the following basic code: Client JavaScript <script type="text/javascript"> function updateFeed(data) { $('#time').text(data); } function catchAll(data, type) { console.log(data); console.log(type); } $.comet.connect('/broadcast/sub?channel=getIt'); $.comet.bind(updateFeed, 'feed'); $.comet.bind(catchAll); $('#kill-button').click(function() { $.comet.unbind(updateFeed, 'feed'); }); </script> What I can understand from this is that the client will keep on listening to the url followed by /broadcast/sub=getIt. When there is a message it will fire updateFeed. Pretty basic and understandable IMO. Nginx http push module config default_type application/octet-stream; sendfile on; keepalive_timeout 65; push_authorized_channels_only off; server { listen 80; location /broadcast { location = /broadcast/sub { set $push_channel_id $arg_channel; push_subscriber; push_subscriber_concurrency broadcast; push_channel_group broadcast; } location = /broadcast/pub { set $push_channel_id $arg_channel; push_publisher; push_min_message_buffer_length 5; push_max_message_buffer_length 20; push_message_timeout 5s; push_channel_group broadcast; } } } Ok now this tells nginx to listen at port 80 for any calls to /broadcast/sub and it will give back any responses sent to /broadcast/pub. Pretty basic also. This part is not so hard to understand, and is well documented over the internet. Most of the time there is a ruby or a php file behind this that does the broadcasting. My idea is to have node.js broadcasting /broadcast/pub. I think this will let me have persistent streaming data from the server to the client without breaking the connection. I tried the long-polling approach with looping the request but I think this will be more efficient. Or is this not going to work. Node.js file Now to create the Node.js i'm lost. First off all I don't know how to have node.js to work in this way. The setup I used for long polling is as follows: var sys = require('sys'), http = require('http'); http.createServer(function (req, res) { res.writeHead(200, {'Content-Type': 'text/html'}); res.write(new Date()); res.close(); seTimeout('',1000); }).listen(8000); This listens to port 8000 and just writes on the response variable. For long polling my nginx.config looked something like this: server { listen 80; server_name _; location / { proxy_pass http://mydomain.com:8080$request_uri; include /etc/nginx/proxy.conf; } } This just redirected the port 80 to 8000 and this worked fine. Does anyone have an idea on how to have Node.js act in a way Comet understands it. Would be really nice and you will help me out a lot. Recources used An example where this is done with ruby instead of Node.js jQuery.comet Nginx HTTP push module homepage Faye: a Comet client and server for Node.js and Rack To use faye I have to install the comet client, but I want to use the one supplied with Nginx. Thats why I don't just use faye. The one nginx uses is much more optimzed. extra Persistant connections Going evented with Node.js

    Read the article

  • ModalPopupExtender and validation problems

    - by Malachi
    The problem I am facing is that when there is validation on a page and I am trying to display a model pop-up, the pop-up is not getting displayed. And by using fire-bug I have noticed that an error is being thrown. The button that is used to display the pop-up has cause validation set to false so I am stuck as to what is causing the error. I have created a sample page to isolate the problem that I am having, any help would be greatly appreciated. The Error function () {Array.remove(Page_ValidationSummaries, document.getElementById("ValidationSummary1"));}(function () {var fn = function () {AjaxControlToolkit.ModalPopupBehavior.invokeViaServer("mpeSelectClient", true);Sys.Application.remove_load(fn);};Sys.Application.add_load(fn);}) is not a function http://localhost:1131/WebForm1.aspx Line 136 ASP <%@ Page Language="C#" AutoEventWireup="true" CodeBehind="WebForm1.aspx.cs" Inherits="CLIck10.WebForm1" %> <%@ Register Assembly="AjaxControlToolkit" Namespace="AjaxControlToolkit" TagPrefix="ajaxToolkit" %> <!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd"> <html xmlns="http://www.w3.org/1999/xhtml" > <head runat="server"> <title></title> </head> <body> <form id="form1" runat="server"> <asp:ScriptManager ID="ScriptManager1" runat="server"> </asp:ScriptManager> <div> <asp:Button ID="btnPush" runat="server" Text="Push" CausesValidation="false" onclick="btnPush_Click" /> <asp:TextBox ID="txtVal" runat="server" /> <asp:RequiredFieldValidator ID="RequiredFieldValidator1" runat="server" ControlToValidate="txtVal" ErrorMessage="RequiredFieldValidator" /> <asp:ValidationSummary ID="ValidationSummary1" runat="server" /> <asp:Panel ID="pnlSelectClient" Style="display: none" CssClass="box" runat="server"> <asp:UpdatePanel ID="upnlSelectClient" runat="server"> <ContentTemplate> <asp:Button ID="btnOK" runat="server" UseSubmitBehavior="true" Text="OK" CausesValidation="false" OnClick="btnOK_Click" /> <asp:Button ID="btnCancel" runat="server" Text="Cancel" CausesValidation="false" OnClick="btnCancel_Click" /> </ContentTemplate> </asp:UpdatePanel> </asp:Panel> <input id="popupDummy" runat="server" style="display:none" /> <ajaxToolkit:ModalPopupExtender ID="mpeSelectClient" runat="server" TargetControlID="popupDummy" PopupControlID="pnlSelectClient" OkControlID="popupDummy" BackgroundCssClass="modalBackground" CancelControlID="btnCancel" DropShadow="true" /> </div> </form> Code Behind using System; using System.Collections.Generic; using System.Linq; using System.Web; using System.Web.UI; using System.Web.UI.WebControls; namespace CLIck10 { public partial class WebForm1 : System.Web.UI.Page { protected void Page_Load(object sender, EventArgs e) { } protected void btnOK_Click(object sender, EventArgs e) { mpeSelectClient.Hide(); } protected void btnCancel_Click(object sender, EventArgs e) { mpeSelectClient.Hide(); } protected void btnPush_Click(object sender, EventArgs e) { mpeSelectClient.Show(); } } }

    Read the article

  • Loading a PyML multiclass classifier... why isn't this working?

    - by Michael Aaron Safyan
    This is a followup from "Save PyML.classifiers.multi.OneAgainstRest(SVM()) object?". I am using PyML for a computer vision project (pyimgattr), and have been having trouble storing/loading a multiclass classifier. When attempting to load one of the SVMs in a composite classifier, with loadSVM, I am getting: ValueError: invalid literal for float(): rest Note that this does not happen with the first classifier that I load, only with the second. What is causing this error, and what can I do to get around this so that I can properly load the classifier? Details To better understand the trouble I'm running into, you may want to look at pyimgattr.py (currently revision 11). I am invoking the program with "./pyimgattr.py train" which trains the classifier (invokes train on line 571, which trains the classifier with trainmulticlassclassifier on line 490 and saves it with storemulticlassclassifier on line 529), and then invoking the program with "./pyimgattr.py test" which loads the classifier in order to test it with the testing dataset (invokes test on line 628, which invokes loadmulticlassclassifier on line 549). The multiclass classifier consists of several one-against-rest SVMs which are saved individually. The loadmulticlassclassifier function loads these individually by calling loadSVM() on several different files. It is in this call to loadSVM (done indirectly in loadclassifier on line 517) that I get an error. The first of the one-against-rest classifiers loads successfully, but the second one does not. A transcript is as follows: $ ./pyimgattr.py test [INFO] pyimgattr -- Loading attributes from "classifiers/attributes.lst"... [INFO] pyimgattr -- Loading classnames from "classifiers/classnames.lst"... [INFO] pyimgattr -- Loading dataset "attribute_data/apascal_test.txt"... [INFO] pyimgattr -- Loaded dataset "attribute_data/apascal_test.txt". [INFO] pyimgattr -- Loading multiclass classifier from "classifiers/classnames_from_attributes"... [INFO] pyimgattr -- Constructing object into which to store loaded data... [INFO] pyimgattr -- Loading manifest data... [INFO] pyimgattr -- Loading classifier from "classifiers/classnames_from_attributes/aeroplane.svm".... scanned 100 patterns scanned 200 patterns read 100 patterns read 200 patterns {'50': 38, '60': 45, '61': 46, '62': 47, '49': 37, '52': 39, '53': 40, '24': 16, '25': 17, '26': 18, '27': 19, '20': 12, '21': 13, '22': 14, '23': 15, '46': 34, '47': 35, '28': 20, '29': 21, '40': 32, '41': 33, '1': 1, '0': 0, '3': 3, '2': 2, '5': 5, '4': 4, '7': 7, '6': 6, '8': 8, '58': 44, '39': 31, '38': 30, '15': 9, '48': 36, '16': 10, '19': 11, '32': 24, '31': 23, '30': 22, '37': 29, '36': 28, '35': 27, '34': 26, '33': 25, '55': 42, '54': 41, '57': 43} read 250 patterns in LinearSparseSVModel done LinearSparseSVModel constructed model [INFO] pyimgattr -- Loaded classifier from "classifiers/classnames_from_attributes/aeroplane.svm". [INFO] pyimgattr -- Loading classifier from "classifiers/classnames_from_attributes/bicycle.svm".... label at None delimiter , Traceback (most recent call last): File "./pyimgattr.py", line 797, in sys.exit(main(sys.argv)); File "./pyimgattr.py", line 782, in main return test(attributes_file,classnames_file,testing_annotations_file,testing_dataset_path,classifiers_path,logger); File "./pyimgattr.py", line 635, in test multiclass_classnames_from_attributes_classifier = loadmulticlassclassifier(classnames_from_attributes_folder,logger); File "./pyimgattr.py", line 529, in loadmulticlassclassifier classifiers.append(loadclassifier(os.path.join(filename,label+".svm"),logger)); File "./pyimgattr.py", line 502, in loadclassifier result=loadSVM(filename,datasetClass = SparseDataSet); File "/Library/Python/2.6/site-packages/PyML/classifiers/svm.py", line 328, in loadSVM data = datasetClass(fileName, **args) File "/Library/Python/2.6/site-packages/PyML/containers/vectorDatasets.py", line 224, in __init__ BaseVectorDataSet.__init__(self, arg, **args) File "/Library/Python/2.6/site-packages/PyML/containers/baseDatasets.py", line 214, in __init__ self.constructFromFile(arg, **args) File "/Library/Python/2.6/site-packages/PyML/containers/baseDatasets.py", line 243, in constructFromFile for x in parser : File "/Library/Python/2.6/site-packages/PyML/containers/parsers.py", line 426, in next x = [float(token) for token in tokens[self._first:self._last]] ValueError: invalid literal for float(): rest

    Read the article

  • Python bindings for a vala library

    - by celil
    I am trying to create python bindings to a vala library using the following IBM tutorial as a reference. My initial directory has the following two files: test.vala using GLib; namespace Test { public class Test : Object { public int sum(int x, int y) { return x + y; } } } test.override %% headers #include <Python.h> #include "pygobject.h" #include "test.h" %% modulename test %% import gobject.GObject as PyGObject_Type %% ignore-glob *_get_type %% and try to build the python module source test_wrap.c using the following code build.sh #/usr/bin/env bash valac test.vala -CH test.h python /usr/share/pygobject/2.0/codegen/h2def.py test.h > test.defs pygobject-codegen-2.0 -o test.override -p test test.defs > test_wrap.c However, the last command fails with an error $ ./build.sh Traceback (most recent call last): File "/usr/share/pygobject/2.0/codegen/codegen.py", line 1720, in <module> sys.exit(main(sys.argv)) File "/usr/share/pygobject/2.0/codegen/codegen.py", line 1672, in main o = override.Overrides(arg) File "/usr/share/pygobject/2.0/codegen/override.py", line 52, in __init__ self.handle_file(filename) File "/usr/share/pygobject/2.0/codegen/override.py", line 84, in handle_file self.__parse_override(buf, startline, filename) File "/usr/share/pygobject/2.0/codegen/override.py", line 96, in __parse_override command = words[0] IndexError: list index out of range Is this a bug in pygobject, or is something wrong with my setup? What is the best way to call code written in vala from python? EDIT: Removing the extra line fixed the current problem, but now as I proceed to build the python module, I am facing another problem. Adding the following C file to the existing two in the directory: test_module.c #include <Python.h> void test_register_classes (PyObject *d); extern PyMethodDef test_functions[]; DL_EXPORT(void) inittest(void) { PyObject *m, *d; init_pygobject(); m = Py_InitModule("test", test_functions); d = PyModule_GetDict(m); test_register_classes(d); if (PyErr_Occurred ()) { Py_FatalError ("can't initialise module test"); } } and building with the following script build.sh #/usr/bin/env bash valac test.vala -CH test.h python /usr/share/pygobject/2.0/codegen/h2def.py test.h > test.defs pygobject-codegen-2.0 -o test.override -p test test.defs > test_wrap.c CFLAGS="`pkg-config --cflags pygobject-2.0` -I/usr/include/python2.6/ -I." LDFLAGS="`pkg-config --libs pygobject-2.0`" gcc $CFLAGS -fPIC -c test.c gcc $CFLAGS -fPIC -c test_wrap.c gcc $CFLAGS -fPIC -c test_module.c gcc $LDFLAGS -shared test.o test_wrap.o test_module.o -o test.so python -c 'import test; exit()' results in an error: $ ./build.sh ***INFO*** The coverage of global functions is 100.00% (1/1) ***INFO*** The coverage of methods is 100.00% (1/1) ***INFO*** There are no declared virtual proxies. ***INFO*** There are no declared virtual accessors. ***INFO*** There are no declared interface proxies. Traceback (most recent call last): File "<string>", line 1, in <module> ImportError: ./test.so: undefined symbol: init_pygobject Where is the init_pygobject symbol defined? What have I missed linking to?

    Read the article

  • Socket in C: recv overwrite a char[]

    - by Possa
    Hi all, I'm trying to make a little client-server script like many others that I've done in the past. But in this one I have a problem. It is better if I post the code and the output it give me. Code: #include <mysql.h> //not important now #include <stdlib.h> #include <sys/types.h> #include <sys/socket.h> #include <netinet/in.h> #include <arpa/inet.h> #include <netdb.h> #include <stdio.h> #include <stdlib.h> #include <unistd.h> #include <signal.h> #include <string.h> //constant definition #define SERVER_PORT 2121 #define LINESIZE 21 //global var definition char victim_ip[LINESIZE], file_write[LINESIZE], hacker_ip[LINESIZE]; //function void leggi (int); //not use now for debugging purpose //void scriviDB (); //not important now main () { int sock, client_len, fd; struct sockaddr_in server, client; // transport end point if((sock = socket(AF_INET, SOCK_STREAM, 0)) == -1) { perror("system call socket fail"); exit(1); } server.sin_family = AF_INET; server.sin_addr.s_addr = inet_addr("10.10.10.1"); server.sin_port = htons(SERVER_PORT); // binding address at transport end point if (bind(sock, (struct sockaddr *)&server, sizeof server) == -1) { perror("system call bind fail"); exit(1); } //fprintf(stderr, "Server open: listening.\n"); listen(sock, 5); /* managae client connection */ while (1) { client_len = sizeof(client); if ((fd = accept(sock, (struct sockaddr *)&client, &client_len)) < 0) { perror("accepting connection"); exit(1); } strcpy(hacker_ip, inet_ntoa(client.sin_addr)); printf("1 %s\n", hacker_ip); //debugging purpose //leggi(fd); ////////////////////////// //receive client recv(fd, victim_ip, LINESIZE, 0); victim_ip[sizeof(victim_ip)] = '\0'; printf("2 %s\n", hacker_ip); //debugging purpose recv(fd, file_write, LINESIZE, 0); file_write[sizeof(file_write)] = '\0'; printf("3 %s\n", hacker_ip); //debugging purpose printf("%s@%s for %s\n", file_write, victim_ip, hacker_ip); //send to client send(fd, hacker_ip, 40, 0); //now is hacker_ip for debug ///////////////////////// close(fd); }//end while exit(0); } //end main Client send string: ./send -i 10.10.10.4 -f filename.ext so the script send -i (IP) and -f (FILE) at the server. Here's my output server side: 1 10.10.10.6 2 10.10.10.6 3 [email protected] for As you can see the printf(3) and the printf(ip,file,ip) fail. I don't know how and where but someone overwrite my hacker_ip string. Thanks for your help! :)

    Read the article

  • Why isn't my algorithm for find the biggest and smallest inputs working?

    - by Matt Ellen
    I have started a new job, and with it comes a new language: Ironpython. Thankfully a good language :D Before starting I got to grips with Python on the whole, but that was only a week's worth of learning. Now I'm writing actual code. I've been charged with writing an algorithm that finds the best input parameter to collect data with. The basic algorithm is (as I've been instructed): Set the input parameter to a good guess Start collecting data When data is available stop collecting find the highest point If the point before this (i.e. for the previous parameter value) was higher and the point before that was lower then we've found the max otherwise the input parameter is increased by the initial guess. goto 2 If the max is found then the min needs to be found. To do this the algorithm carries on increasing the input, but by 1/10 of the max, until the current point is greater than the previous point and the point before that is also greater. Once the min is found then the algorithm stops. Currently I have a simplified data generator outputting the sin of the input, so that I know that the min value should be PI and the max value should be PI/2 The main Python code looks like this (don't worry, this is just for my edification, I don't write real code like this): import sys sys.path.append(r"F:\Programming Source\C#\PythonHelp\PythonHelp\bin\Debug") import clr clr.AddReferenceToFile("PythonHelpClasses.dll") import PythonHelpClasses from PHCStruct import Helper from System import Math helper = Helper() def run(): b = PythonHelpClasses.Executor() a = PythonHelpClasses.HasAnEvent() b.Input = 0.0 helper.__init__() def AnEventHandler(e): b.Stop() h = helper h.lastLastVal, h.lastVal, h.currentVal = h.lastVal, h.currentVal, e.Number if h.lastLastVal < h.lastVal and h.currentVal < h.lastVal and h.NotPast90: h.NotPast90 = False h.bestInput = h.lastInput inputInc = 0.0 if h.NotPast90: inputInc = Math.PI/10.0 else: inputInc = h.bestInput/10.0 if h.lastLastVal > h.lastVal and h.currentVal > h.lastVal and h.NotPast180: h.NotPast180 = False if h.NotPast180: h.lastInput, b.Input = b.Input, b.Input + inputInc b.Start(a) else: print "Best input:", h.bestInput print "Last input:", h.lastInput b.Stop() a.AnEvent += AnEventHandler b.Start(a) PHCStruct.py: class Helper(): def __init__(self): self.currentVal = 0 self.lastVal = 0 self.lastLastVal = 0 self.NotPast90 = True self.NotPast180 = True self.bestInput = 0 self.lastInput = 0 PythonHelpClasses has two small classes I wrote in C# before I realised how to do it in Ironpython. Executor runs a delegate asynchronously while it's running member is true. The important code: public void Start(HasAnEvent hae) { running = true; RunDelegate r = new RunDelegate(hae.UpdateNumber); AsyncCallback ac = new AsyncCallback(UpdateDone); IAsyncResult ar = r.BeginInvoke(Input, ac, null); } public void Stop() { running = false; } public void UpdateDone(IAsyncResult ar) { RunDelegate r = (RunDelegate)((AsyncResult)ar).AsyncDelegate; r.EndInvoke(ar); if (running) { AsyncCallback ac = new AsyncCallback(UpdateDone); IAsyncResult ar2 = r.BeginInvoke(Input, ac, null); } } HasAnEvent has a function that generates the sin of its input and fires an event with that result as its argument. i.e.: public void UpdateNumber(double val) { AnEventArgs e = new AnEventArgs(Math.Sin(val)); System.Threading.Thread.Sleep(1000); if (null != AnEvent) { AnEvent(e); } } The sleep is in there just to slow things down a bit. The problem I am getting is that the algorithm is not coming up with the best input being PI/2 and the final input being PI, but I can't see why. Also the best and final inputs are different each time I run the programme. Can anyone see why? Also when the algorithm terminates the best and final inputs are printed to the screen multiple times, not just once. Can someone explain why?

    Read the article

  • Help with simple linux shell implementation

    - by nunos
    I am implementing a simple version of a linux shell in c. I have succesfully written the parser, but I am having some trouble forking out the child process. However, I think the problem is due to arrays, pointers and such, because just started C with this project and am not still very knowledgable with them. I am getting a segmentation fault and don't know where from. Any help is greatly appreciated. #include <stdio.h> #include <stdlib.h> #include <unistd.h> #include <string.h> #include <sys/wait.h> #include <sys/types.h> #define MAX_COMMAND_LENGTH 250 #define MAX_ARG_LENGTH 250 typedef enum {false, true} bool; typedef struct { char **arg; char *infile; char *outfile; int background; } Command_Info; int parse_cmd(char *cmd_line, Command_Info *cmd_info) { char *arg; char *args[MAX_ARG_LENGTH]; int i = 0; arg = strtok(cmd_line, " "); while (arg != NULL) { args[i] = arg; arg = strtok(NULL, " "); i++; } int num_elems = i; if (num_elems == 0) return -1; cmd_info->infile = NULL; cmd_info->outfile = NULL; cmd_info->background = 0; int iarg = 0; for (i = 0; i < num_elems-1; i++) { if (!strcmp(args[i], "<")) { if (args[i+1] != NULL) cmd_info->infile = args[++i]; else return -1; } else if (!strcmp(args[i], ">")) { if (args[i+1] != NULL) cmd_info->outfile = args[++i]; else return -1; } else cmd_info->arg[iarg++] = args[i]; } if (!strcmp(args[i], "&")) cmd_info->background = true; else cmd_info->arg[iarg++] = args[i]; cmd_info->arg[iarg] = NULL; return 0; } void print_cmd(Command_Info *cmd_info) { int i; for (i = 0; cmd_info->arg[i] != NULL; i++) printf("arg[%d]=\"%s\"\n", i, cmd_info->arg[i]); printf("arg[%d]=\"%s\"\n", i, cmd_info->arg[i]); printf("infile=\"%s\"\n", cmd_info->infile); printf("outfile=\"%s\"\n", cmd_info->outfile); printf("background=\"%d\"\n", cmd_info->background); } void get_cmd(char* str) { fgets(str, MAX_COMMAND_LENGTH, stdin); str[strlen(str)-1] = '\0'; //apaga o '\n' do fim } pid_t exec_simple(Command_Info *cmd_info) { pid_t pid = fork(); if (pid < 0) { perror("Fork Error"); return -1; } if (pid == 0) { execvp(cmd_info->arg[0], cmd_info->arg); perror(cmd_info->arg[0]); exit(1); } return pid; } int main(int argc, char* argv[]) { while (true) { char cmd_line[MAX_COMMAND_LENGTH]; Command_Info cmd_info; printf(">>> "); get_cmd(cmd_line); if ( (parse_cmd(cmd_line, &cmd_info) == -1) ) return -1; parse_cmd(cmd_line, &cmd_info); if (!strcmp(cmd_info.arg[0], "exit")) exit(0); pid_t pid = exec_simple(&cmd_info); waitpid(pid, NULL, 0); } return 0; } Thanks.

    Read the article

  • using one data template in another data template in WPF

    - by Sowmya
    Hi, I have two data templates, one of which is the subset of another like below: <ResourceDictionary xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" xmlns:igEditors="http://infragistics.com/Editors" xmlns:sys="clr-namespace:System;assembly=mscorlib" xmlns:controls="clr-namespace:Client.UI.WPF;assembly=Client.UI.WPF" xmlns:d="http://schemas.microsoft.com/expression/blend/2006" > <ResourceDictionary.MergedDictionaries> <ResourceDictionary Source="pack://application:,,,/Client.Resources.WPF.Styles;Component/Styles/CommonStyles.xaml"/> </ResourceDictionary.MergedDictionaries> <DataTemplate x:Key="XYZDataTemplate"> <Grid x:Name="_rootGrid" DataContext="{Binding DataContext}" HorizontalAlignment="Left" VerticalAlignment="Top"> <Grid.RowDefinitions> <RowDefinition/> <RowDefinition/> <RowDefinition/> </Grid.RowDefinitions> <Grid.ColumnDefinitions> <ColumnDefinition Width="Auto"/> <ColumnDefinition Width="Auto"/> <ColumnDefinition Width="Auto"/> <ColumnDefinition Width="Auto"/> <ColumnDefinition Width="Auto"/> </Grid.ColumnDefinitions> <controls:ValueDisplay Grid.Row="0" Grid.Column="0" LabelText="Build number" x:Name="buildNumber" HorizontalAlignment="Left" VerticalAlignment="Top" Width="120" Margin="5,10,0,0"> <igEditors:XamTextEditor /> </controls:ValueDisplay> <controls:ValueDisplay Grid.Row="0" Grid.Column="1" LabelText="Tool version" x:Name="toolVersion" HorizontalAlignment="Left" VerticalAlignment="Top" Width="120" Margin="20,10,0,0"> <igEditors:XamTextEditor IsReadOnly="True"/> </controls:ValueDisplay> </Grid> </DataTemplate> and the other is like below: <ResourceDictionary xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" xmlns:igEditors="http://infragistics.com/Editors" xmlns:sys="clr-namespace:System;assembly=mscorlib" xmlns:controls="clr-namespace:BHI.ULSS.Client.UI.WPF;assembly=ULSS.Client.UI.WPF" xmlns:d="http://schemas.microsoft.com/expression/blend/2006" > <DataTemplate x:Key="ABCDataTemplate" > <Grid x:Name="_rootGrid" DataContext="{Binding DataContext}" HorizontalAlignment="Left" VerticalAlignment="Top"> <Grid.RowDefinitions> <RowDefinition/> <RowDefinition/> <RowDefinition/> </Grid.RowDefinitions> <Grid.ColumnDefinitions> <ColumnDefinition Width="Auto"/> <ColumnDefinition Width="Auto"/> <ColumnDefinition Width="Auto"/> <ColumnDefinition Width="Auto"/> <ColumnDefinition Width="Auto"/> </Grid.ColumnDefinitions> <controls:ValueDisplay Grid.Row="0" Grid.Column="0" LabelText="Build number" x:Name="buildNumber" HorizontalAlignment="Left" VerticalAlignment="Top" Width="120" Margin="5,10,0,0"> <igEditors:XamTextEditor /> </controls:ValueDisplay> <controls:ValueDisplay Grid.Row="0" Grid.Column="1" LabelText="Tool version" x:Name="toolVersion" HorizontalAlignment="Left" VerticalAlignment="Top" Width="120" Margin="20,10,0,0"> <igEditors:XamTextEditor IsReadOnly="True"/> </controls:ValueDisplay> <controls:ValueDisplay Grid.Row="0" Grid.Column="2" LabelText="Size" ShowUnit="True" x:Name="size" HorizontalAlignment="Left" VerticalAlignment="Top" Width="120" Margin="20,10,0,0"> <igEditors:XamTextEditor/> </controls:ValueDisplay> </Grid> </DataTemplate> XYZDataTemplate is a subset of the ABCDataTemplate as the first two fields in both the data templates are common, so I was wondering if it is possible to replace the redundant code in the ABCDataTemplate with that of the XYZDataTemplate for code maintainability? Could anyone please suggest if would this be a right approach, if so how can I acheive that? Thanks in advance, Sowmya

    Read the article

  • about getadrrinfo() C++?

    - by Isavel
    I'm reading this book called beej's guide to network programming and there's a part in the book were it provide a sample code which illustrate the use of getaddrinfo(); the book state that the code below "will print the IP addresses for whatever host you specify on the command line" - beej's guide to network programming. now I'm curious and want to try it out and run the code, but I guess the code was develop in UNIX environment and I'm using visual studio 2012 windows 7 OS, and most of the headers was not supported so I did a bit of research and find out that I need to include the winsock.h and ws2_32.lib for windows, for it to get working, fortunately everything compiled no errors, but when I run it using the debugger and put in 'www.google.com' as command argument I was disappointed that it did not print any ipaddress, the output that I got from the console is "getaddrinfo: E" what does the letter E mean? Do I need to configure something out of the debugger? Interestingly I left the command argument blank and the output changed to "usage: showip hostname" Any help would be appreciated. #ifdef _WIN32 #endif #include <sys/types.h> #include <winsock2.h> #include <ws2tcpip.h> #include <iostream> using namespace std; #include <stdio.h> #include <string.h> #include <sys/types.h> #include <winsock.h> #pragma comment(lib, "ws2_32.lib") int main(int argc, char *argv[]) { struct addrinfo hints, *res, *p; int status; char ipstr[INET6_ADDRSTRLEN]; if (argc != 2) { fprintf(stderr,"usage: showip hostname\n"); system("PAUSE"); return 1; } memset(&hints, 0, sizeof hints); hints.ai_family = AF_UNSPEC; // AF_INET or AF_INET6 to force version hints.ai_socktype = SOCK_STREAM; if ((status = getaddrinfo(argv[1], NULL, &hints, &res)) != 0) { fprintf(stderr, "getaddrinfo: %s\n", gai_strerror(status)); system("PAUSE"); return 2; } printf("IP addresses for %s:\n\n", argv[1]); for(p = res;p != NULL; p = p->ai_next) { void *addr; char *ipver; // get the pointer to the address itself, // different fields in IPv4 and IPv6: if (p->ai_family == AF_INET) { // IPv4 struct sockaddr_in *ipv4 = (struct sockaddr_in *)p->ai_addr; addr = &(ipv4->sin_addr); ipver = "IPv4"; } else { // IPv6 struct sockaddr_in6 *ipv6 = (struct sockaddr_in6 *)p->ai_addr; addr = &(ipv6->sin6_addr); ipver = "IPv6"; } // convert the IP to a string and print it: inet_ntop(p->ai_family, addr, ipstr, sizeof ipstr); printf(" %s: %s\n", ipver, ipstr); } freeaddrinfo(res); // free the linked list system("PAUSE"); return 0; }

    Read the article

  • SQL SERVER – Find Max Worker Count using DMV – 32 Bit and 64 Bit

    - by pinaldave
    During several recent training courses, I found it very interesting that Worker Thread is not quite known to everyone despite the fact that it is a very important feature. At some point in the discussion, one of the attendees mentioned that we can double the Worker Thread if we double the CPU (add the same number of CPU that we have on current system). The same discussion has triggered this quick article. Here is the DMV which can be used to find out Max Worker Count SELECT max_workers_count FROM sys.dm_os_sys_info Let us run the above query on my system and find the results. As my system is 32 bit and I have two CPU, the Max Worker Count is displayed as 512. To address the previous discussion, adding more CPU does not necessarily double the Worker Count. In fact, the logic behind this simple principle is as follows: For x86 (32-bit) upto 4 logical processors  max worker threads = 256 For x86 (32-bit) more than 4 logical processors  max worker threads = 256 + ((# Procs – 4) * 8) For x64 (64-bit) upto 4 logical processors  max worker threads = 512 For x64 (64-bit) more than 4 logical processors  max worker threads = 512+ ((# Procs – 4) * 8) In addition to this, you can configure the Max Worker Thread by using SSMS. Go to Server Node >> Right Click and Select Property >> Select Process and modify setting under Worker Threads. According to Book On Line, the default Worker Thread settings are appropriate for most of the systems. Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, SQL, SQL Authority, SQL Query, SQL Scripts, SQL Server, SQL System Table, SQL Tips and Tricks, T SQL, Technology Tagged: SQL DMV

    Read the article

  • Upgrade Your Existing BI Publisher 11g (11.1.1.3) to 11.1.1.5

    - by Kan Nishida
    It’s already more than a month now since BI Publisher 11.1.1.5 was released at beginning of May. Have you already tried out many of the great new features? If you are already running on the first version of BI Publisher 11g (11.1.1.3) you might wonder how to upgrade the existing BI Publisher to the 11.1.1.5 version. There are two ways to do this, one is ‘Out-Place’ and another is ‘In-Place’. The ‘Out-Place’ would be quite simple. Basically you will need to install the whole BI or just BI Publisher standalone R11.1.1.5 at a different location then you can switch the catalog to the existing one so that all the reports will be there in the new 11.1.1.5 environment. But sometimes things are not that simple, you might have some custom applications or configuration on the original environment and you want to keep all of them with the upgraded environment. For such scenarios, there is the ‘In-Place’ upgrade, which overrides on top of the original environment only the parts relevant for BI and BI Publisher, and that’s what I’m going to talk about today. Here is the basic steps of the ‘In-Place’ upgrade. Upgrade WebLogic Server to 10.3.5 Upgrade BI System to 11.1.1.5 Upgrade Database Schema Re-register BI Components Upgrade FMW (Fusion Middleware) Configuration Upgrade BI Catalog There is a section that talks about this upgrade from 11.1.1.3 to 11.1.1.5 as part of the overall upgrade document. But I hope my blog post summarized it and made it simple for you to cover only what’s necessary. Upgrade Document: http://download.oracle.com/docs/cd/E21764_01/bi.1111/e16452/bi_plan.htm#BABECJJH Before You Start Stop BI System and Backup I can’t emphasize enough, but before you start PLEASE make sure you take a backup of the existing environments first. You want to stop all WebLogic Servers, Node Manager, OPMN, and OPMN-managed system components that are part of your Oracle BI domains. If you’re on Windows you can do this by simply selecting ‘Stop BI Services’ menu. Then backup the whole system. Upgrade WebLogic Server to 10.3.5 Download WebLogic Server 10.3.5 Upgrade Installer With BI 11.1.1.3 installation your WebLogic Server (WLS) is 10.3.3 and you need to upgrade this to 10.3.5 before upgrading the BI part. In order to upgrade you will need this 10.3.5 upgrade version of WLS, which you can download from our support web site (https://support.oracle.com) You can find the detail information about the installation and the patch numbers for the WLS upgrade installer on this document. Just for your short cut, if you are running on Windows or Linux (x86) here is the patch number for your platform. Windows 32 bit: 12395517: Linux: 12395517 Upgrade WebLogic Server 1. After unzip the downloaded file, launch wls1035_upgrade_win32.exe if you’re on Windows. 2. Accept all the default values and keep ‘Next’ till end, and start the upgrade. Once the upgrade process completes you’ll see the following window. Now let’s move to the BI upgrade. Upgrade BI Platform to 11.1.1.5 with Software Only Install Download BI 11.1.1.5 You can download the 11.1.1.5 version from our OTN page for your evaluation or development. For the production use it’s recommended to download from eDelivery. 1. Launch the installer by double click ‘setup.exe’ (for Windows) 2. Select ‘Software Only Install’ option 3. Select your original Oracle Home where you installed BI 11.1.1.3. 4. Click ‘Install’ button to start the installation. And now the software part of the BI has been upgraded to 11.1.1.5. Now let’s move to the database schema upgrade. Upgrade Database Schema with Patch Assistant You need to upgrade the BIPLATFORM and MDS Schemas. You can use the Patch Assistant utility to do this, and here is an example assuming you’ve created the schema with ‘DEV’ prefix, otherwise change it with yours accordingly. Upgrade BIPLATFORM schema (if you created this schema with DEV_ prev) psa.bat -dbConnectString localhost:1521:orcl -dbaUserName sys -schemaUserName DEV_BIPLATFORM Upgrade MDS schema (if you created this schema with DEV_ prev) psa.bat -dbConnectString localhost:1521:orcl -dbaUserName sys -schemaUserName DEV_MDS Re-register BI System components Now you need to re-register your BI system components such as BI Server, BI Presentation Server, etc to the Fusion Middleware system. You can do this by running ‘upgradenonj2eeapp.bat (or .sh)’ command, which can be found at %ORACLE_HOME%/opmn/bin. Before you run, you need to start the WLS Server and make sure your WLS environment is not locked. If it’s locked then you need to release the system from the Fusion Middleware console before you run the following command. Here is the syntax for the ‘upgradenonj2eeapp.bat (or .sh) command.  upgradenonj2eeapp.bat    -oracleInstance Instance_Home_Location    -adminHost WebLogic_Server_Host_Name    -adminPort administration_server_port_number    -adminUsername administration_server_user And here is an example: cd %BI_HOME%\opmn\bin upgradenonj2eeapp.bat -oracleInstance C:\biee11\instances\instance1 -adminHost localhost -adminPort 7001 -adminUsername weblogic Upgrade Fusion Middleware Configuration There are a couple things on the Fusion Middleware need to be upgraded for the BI system to work. Here is a list of the components to upgrade. Upgrade Shared Library (JRF) Upgrade Fusion Middleware Security (OPSS) Upgrade Code Grants Upgrade OWSM Policy Repository Before moving forward, you need to stop the WebLogic Server. Here is an example. cd %MW_HOME%user_projects\domains\bifoundation_domain\binstopWebLogic.cmd And, let’s start with ‘Upgrade Shared Library (JRF)’. Upgrade Shared Library (JRF) You can use updateJRF() WLST command to upgrade the shared libraries in your domain. Before you do this, you need to stop all running instances, Managed Servers, Administration Server, and Node Manager in the domain. Here is an example of the ‘upgradeJRF()’ command: cd %MW_HOME%\oracle_common\common\bin wlst.cmd upgradeJRF('C:/biee11/user_projects/domains/bifoundation_domain') Upgrade Fusion Middleware Security (OPSS) This step is to upgrade the Fusion Middleware security piece. You can use ‘upgradeOpss()’ WLST command. Here is a syntax for the command. upgradeOpss(jpsConfig="existing_jps_config_file", jaznData="system_jazn_data_file") The ‘existing jps-config.xml file can be found under %DOMAIN_HOME%/config/fmwconfig/jps-config.xml and the ‘system_jazn_data_file’ can be found under %MW_HOME%/oracle_common/modules/oracle.jps_11.1.1/domain_config/system-jazn-data.xml. And here is an example: cd %MW_HOME%\oracle_common\common\bin wlst.cmd upgradeOpss(jpsConfig="c:/biee11/user_projects/domains/bifoundation_domain/config/fmwconfig/jps-config.xml", jaznData="c:/biee11/oracle_common/modules/oracle.jps_11.1.1/domain_config/system-jazn-data.xml") exit() Upgrade Code Grants for Oracle BI Domain And this is the last step for the Fusion Middleware platform upgrade task. You need to run this python script ‘bi-upgrade.py‘ script to configure the code grants necessary to ensure that SSL works correctly for Oracle BI. However, even if you don’t use SSL, you still need to run this script. And if you have multiple BI domains (Enterprise deployment) then you need to run this on each domain. Here is an example: cd %MW_HOME%\oracle_common\common\bin wlst c:\biee11\Oracle_BI1\bin\bi-upgrade.py --bioraclehome c:\biee11\Oracle_BI1 --domainhome c:\biee11\user_projects\domains\bifoundation_domain Upgrade OWSM Policy Repository This is to upgrade OWSM (Oracle Web Service Manager) policy repository, you can use WLST command ‘upgradeWSMPolicyRepository()’. In order to run this command you need to have your WebLogic Server up-and-running. Here is an example. cd %MW_HOME%user_projects\domains\bifoundation_domain\binstopWebLogic.cmd cd %MW_HOME%\oracle_common\common\bin wlst.cmd connect ('weblogic','welcome1','t3://localhost:7001') upgradeWSMPolicyRepository() exit() Upgrade BI Catalogs This step is required only when you have your BI Publisher integrated with BIEE. If your BI Publisher is deployed as a standalone then you don’t need to follow this step. Now finally, you can upgrade the BI catalog. This won’t upgrade your BI Publisher reports themselves, but it just upgrades some attributes information inside the catalog. Before you do this upgrade, make sure the BI system components are not running. You can check the status by the command below. opmnctl status You can do the upgrade by updating a configuration file ‘instanceconfig.xml’, which can be found at %BI_HOME%\instances\instance1\config\coreapplication_obips1, and change the value of ‘UpgradeAndExit’ to be ‘true’. Here is an example: <ps:Catalog xmlns:ps="oracle.bi.presentation.services/config/v1.1"> <ps:UpgradeAndExit>true</ps:UpgradeAndExit> </ps:Catalog> After you made the change and save the file, you need to start the BI Presentation Server. This time you want to start only the BI Presentation Server instead of starting all the servers. You can use ‘opmnctl’ to do so, and here is an example. cd %ORACLE_INSTANCE%\bin opmnctl startproc ias-component=coreapplication_obips1 This would upgrade your BI Catalog to be 11.1.1.5. After the catalog is updated, you can stop the BI Presentation Server so that you can modify the instanceconfig.xml file again to revert the upgradeAndExit value back to ‘false’. Start Explore BI Publisher 11.1.1.5 After all the above steps, you can start all the BI Services, access to the same URL, now you have your BI Publisher and/or BI 11.1.1.5 in your hands. Have fun exploring all the new features of R11.1.1.5!

    Read the article

  • add_shown & add_hiding ModalPopupExtender Events

    - by Yousef_Jadallah
        In this topic, I’ll discuss the Client events we usually need while using ModalPopupExtender. The add_shown fires when the ModalPopupExtender had shown and add_hiding fires when the user cancels it by CancelControlID,note that it fires before hiding the modal. They are useful in many cases, for example may you need to set focus to specific Textbox when the user display the modal, or if you need to reset the controls values inside the Modal after it has been hidden. To declare Client event either in pageLoad javascript function or you can attach the function by Sys.Application.add_load like this: Sys.Application.add_load(modalInit); function modalInit() { var modalPopup = $find('mpeID'); modalPopup.add_hiding(onHiding); } function onHiding(sender, args) { } .csharpcode, .csharpcode pre { font-size: small; color: black; font-family: consolas, "Courier New", courier, monospace; background-color: #ffffff; /*white-space: pre;*/ } .csharpcode pre { margin: 0em; } .csharpcode .rem { color: #008000; } .csharpcode .kwrd { color: #0000ff; } .csharpcode .str { color: #006080; } .csharpcode .op { color: #0000c0; } .csharpcode .preproc { color: #cc6633; } .csharpcode .asp { background-color: #ffff00; } .csharpcode .html { color: #800000; } .csharpcode .attr { color: #ff0000; } .csharpcode .alt { background-color: #f4f4f4; width: 100%; margin: 0em; } .csharpcode .lnum { color: #606060; }   I’ll use the first way in the current example. So lets start with the illustration:   1- In this example am using simple panel which contain UserName and Password Textboxes besides submit and cancel buttons, this Panel will be used as PopupControlID in the ModalPopupExtender : <asp:Panel ID="panModal" runat="server" Height="180px" Width="300px" style="display:none" CssClass="ModalWindow"> <table width="100%" > <tr> <td> User Name </td> <td> <asp:TextBox ID="txtName" runat="server"></asp:TextBox> </td> </tr> <tr> <td> Password </td> <td> <asp:TextBox ID="txtPassword" runat="server" TextMode="Password"></asp:TextBox> </td> </tr> </table> <br /> <asp:Button ID="btnSubmit" runat="server" Text="Submit" /> <asp:Button ID="btnCancel" runat="server" Text="Cancel" /> </asp:Panel>   You can use this simple style for the Panel : <style type="text/css"> .ModalWindow { border: solid; border-width:3px; background:#f0f0f0; } </style> .csharpcode, .csharpcode pre { font-size: small; color: black; font-family: consolas, "Courier New", courier, monospace; background-color: #ffffff; /*white-space: pre;*/ } .csharpcode pre { margin: 0em; } .csharpcode .rem { color: #008000; } .csharpcode .kwrd { color: #0000ff; } .csharpcode .str { color: #006080; } .csharpcode .op { color: #0000c0; } .csharpcode .preproc { color: #cc6633; } .csharpcode .asp { background-color: #ffff00; } .csharpcode .html { color: #800000; } .csharpcode .attr { color: #ff0000; } .csharpcode .alt { background-color: #f4f4f4; width: 100%; margin: 0em; } .csharpcode .lnum { color: #606060; }   2- Create the view button (TargetControlID) as you know this contain the ID of the element that activates the modal popup: <asp:Button ID="btnView" runat="server" Text="View" /> .csharpcode, .csharpcode pre { font-size: small; color: black; font-family: consolas, "Courier New", courier, monospace; background-color: #ffffff; /*white-space: pre;*/ } .csharpcode pre { margin: 0em; } .csharpcode .rem { color: #008000; } .csharpcode .kwrd { color: #0000ff; } .csharpcode .str { color: #006080; } .csharpcode .op { color: #0000c0; } .csharpcode .preproc { color: #cc6633; } .csharpcode .asp { background-color: #ffff00; } .csharpcode .html { color: #800000; } .csharpcode .attr { color: #ff0000; } .csharpcode .alt { background-color: #f4f4f4; width: 100%; margin: 0em; } .csharpcode .lnum { color: #606060; } .csharpcode, .csharpcode pre { font-size: small; color: black; font-family: consolas, "Courier New", courier, monospace; background-color: #ffffff; /*white-space: pre;*/ } .csharpcode pre { margin: 0em; } .csharpcode .rem { color: #008000; } .csharpcode .kwrd { color: #0000ff; } .csharpcode .str { color: #006080; } .csharpcode .op { color: #0000c0; } .csharpcode .preproc { color: #cc6633; } .csharpcode .asp { background-color: #ffff00; } .csharpcode .html { color: #800000; } .csharpcode .attr { color: #ff0000; } .csharpcode .alt { background-color: #f4f4f4; width: 100%; margin: 0em; } .csharpcode .lnum { color: #606060; } .csharpcode, .csharpcode pre { font-size: small; color: black; font-family: consolas, "Courier New", courier, monospace; background-color: #ffffff; /*white-space: pre;*/ } .csharpcode pre { margin: 0em; } .csharpcode .rem { color: #008000; } .csharpcode .kwrd { color: #0000ff; } .csharpcode .str { color: #006080; } .csharpcode .op { color: #0000c0; } .csharpcode .preproc { color: #cc6633; } .csharpcode .asp { background-color: #ffff00; } .csharpcode .html { color: #800000; } .csharpcode .attr { color: #ff0000; } .csharpcode .alt { background-color: #f4f4f4; width: 100%; margin: 0em; } .csharpcode .lnum { color: #606060; }   3-Add the ModalPopupExtender ,moreover don’t forget to add the ScriptManager: <asp:ScriptManager ID="ScriptManager1" runat="server"/> <cc1:ModalPopupExtender ID="ModalPopupExtender1" runat="server" TargetControlID="btnView" PopupControlID="panModal" CancelControlID="btnCancel"/> .csharpcode, .csharpcode pre { font-size: small; color: black; font-family: consolas, "Courier New", courier, monospace; background-color: #ffffff; /*white-space: pre;*/ } .csharpcode pre { margin: 0em; } .csharpcode .rem { color: #008000; } .csharpcode .kwrd { color: #0000ff; } .csharpcode .str { color: #006080; } .csharpcode .op { color: #0000c0; } .csharpcode .preproc { color: #cc6633; } .csharpcode .asp { background-color: #ffff00; } .csharpcode .html { color: #800000; } .csharpcode .attr { color: #ff0000; } .csharpcode .alt { background-color: #f4f4f4; width: 100%; margin: 0em; } .csharpcode .lnum { color: #606060; }     4-In the pageLoad javascript function inside add_shown event set the focus on the txtName , and inside add_hiding reset the two Textboxes. <script language="javascript" type="text/javascript"> function pageLoad() { $find('ModalPopupExtender1').add_shown(function() { alert('add_shown event fires'); $get('<%=txtName.ClientID%>').focus();   });   $find('ModalPopupExtender1').add_hiding(function() { alert('add_hiding event fires'); $get('<%=txtName.ClientID%>').value = ""; $get('<%=txtPassword.ClientID%>').value = "";   }); }   </script> .csharpcode, .csharpcode pre { font-size: small; color: black; font-family: consolas, "Courier New", courier, monospace; background-color: #ffffff; /*white-space: pre;*/ } .csharpcode pre { margin: 0em; } .csharpcode .rem { color: #008000; } .csharpcode .kwrd { color: #0000ff; } .csharpcode .str { color: #006080; } .csharpcode .op { color: #0000c0; } .csharpcode .preproc { color: #cc6633; } .csharpcode .asp { background-color: #ffff00; } .csharpcode .html { color: #800000; } .csharpcode .attr { color: #ff0000; } .csharpcode .alt { background-color: #f4f4f4; width: 100%; margin: 0em; } .csharpcode .lnum { color: #606060; }   I’ve added the two alerts just to let you show when the event fires.   Hope this simple example show you the benefit and how to use these events.

    Read the article

  • Which cloud hosting should I use? [closed]

    - by Alyssa Marie Isk
    Possible Duplicate: How to find web hosting that meets my requirements? If anyone wants to get some real life karma by giving a tiny non-profit pointers, please advise! I posted a thread about our website with highly variable traffic (www.WorldOceansDay.org). The event is on June 8th, and the traffic goes from 100-400/day in the off-season, to about 200,000 trying to access the site at any one time on June 8th. It's a Wordpress site hosted on GoDaddy shared hosting and predictably crashed horribly. From the internet's feedback, we've decided to move to a cloud server to handle the traffic, but I'm a huge newbie and I don't have very reliable mentorship, so I'm turning to crowdsourcing. We're trying to decide between Amazon Web Services and RackSpace Cloud servers. Our sys admin consultant also suggested GoDaddy's new 4GH but I have had such incredibly bad experiences with GoDaddy thus far that I am hesitant. From what I've read on the internet, RackSpace might be cheaper? Would AWS totally break the bank? We don't have a ton of money to spend on hosting. We'll also be using CloudFlare to cache and serve the pages since they're dynamic. I've found a few AWS & RackSpace calculators but I am not 100% on how to find those numbers... GoDaddy? Google Analytics? AWS calc is here: http://calculator.s3.amazonaws.com/calc5.html Rackspace is on the right: http://www.rackspace.com/cloud/cloud_hosting_products/servers/pricing/?0a313380 If anyone can help, or through some miracle feels like walking me through this, I would be incredibly appreciative.

    Read the article

  • polkit: disable all users except those in group wheel?

    - by John Nash
    Is it possible to do the following using 1 polkit .pkla file? Disable all users except those in the wheel group from using polkit. The users in the wheel group will need to provide the root password when using polkit. /etc/polkit-1/localauthority/50-local.d/wheel-only.pkla [disable all users except the wheel group] Identity=unix-group:wheel Action=* ResultAny=??? ResultInactive=??? ResultActive=??? The following file works but you need to provide all the users in /etc/group: [disable all users except those in the wheel group: root and myuser] Identity=unix-user:daemon;unix-user:bin;unix-user:sys;unix-user:adm;unix-user:tty;unix-user:disk;unix-user:lp;unix-user:mail;unix-user:news;unix-user:uucp;unix-user:man;unix-user:proxy;unix-user:kmem;unix-user:dialout;unix-user:fax;unix-user:voice;unix-user:cdrom;unix-user:floppy;unix-user:tape;unix-user:sudo;unix-user:audio;unix-user:dip;unix-user:www-data;unix-user:backup;unix-user:operator;unix-user:list;unix-user:irc;unix-user:src;unix-user:gnats;unix-user:shadow;unix-user:utmp;unix-user:video;unix-user:sasl;unix-user:plugdev;unix-user:staff;unix-user:games;unix-user:users;unix-user:nogroup;unix-user:libuuid;unix-user:crontab;unix-user:messagebus;unix-user:Debian-exim;unix-user:mlocate;unix-user:avahi;unix-user:netdev;unix-user:bluetooth;unix-user:lpadmin;unix-user:ssl-cert;unix-user:fuse;unix-user:utempter;unix-user:Debian-gdm;unix-user:scanner;unix-user:saned;unix-user:i2c;unix-user:haldaemon;unix-user:powerdev Action=* ResultAny=no ResultInactive=no ResultActive=no

    Read the article

< Previous Page | 63 64 65 66 67 68 69 70 71 72 73 74  | Next Page >