  • SqlException: User does not have permission to perform this action.

    - by Oskar Kjellin
    I have been using my website (ASP.NET MVC) in visual studio but now I want to host it on my server. I published from visual studio onto the network share to be used. The server is running Windows Home Server, IIS 6 and SQL Server 2008 R2 (express). In Microsoft SQL Server Management Studio, I've attached the database and made sure that the user IUSR_SERVER is owner of the db. I also made sure that the user Network Service has access. The Web Site is configured in IIS to run anonymously as IUSR_SERVER. I have granted write and read access to IUSR_SERVER as well as Network Service and made sure that nothing is read only. The web.config has this connectionstring: <connectionStrings> <remove name="ApplicationServices" /> <add name="ApplicationServices" connectionString="Data Source=.\SQLExpress;Integrated Security=True;Initial Catalog=MyDatebase" providerName="System.Data.SqlClient" /> </connectionStrings> However, I cannot browse my web site. I only get this error: Server Error in '/' Application. User does not have permission to perform this action. Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.Data.SqlClient.SqlException: User does not have permission to perform this action. Source Error: An unhandled exception was generated during the execution of the current web request. Information regarding the origin and location of the exception can be identified using the exception stack trace below. Stack Trace: [SqlException (0x80131904): User does not have permission to perform this action.] System.Data.SqlClient.SqlInternalConnection.OnError(SqlException exception, Boolean breakConnection) +4846887 System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj) +194 Feels like I've tried everything. Would be very grateful for your aid in this.

    Read the article

  • Cannot connect to database,.Login failed for user

    - by kishorejangid
    Yesterday my database was connected perfectly.. We have installed Windows Server 2008 R2 on our server and the i have added the user to the client PC name SMTECH5 with user jangid Now my database is not connecting using windows authentication. only the master database is connecting.. here are somw of the error throwned TITLE: Connect to Database Engine Cannot connect to SMTECH5\COLLEGEERP. ADDITIONAL INFORMATION: Cannot open user default database. Login failed. Login failed for user 'SMTECH\jangid'. (Microsoft SQL Server, Error: 4064) For help, click: http://go.microsoft.com/fwlink?ProdName=Microsoft+SQL+Server&EvtSrc=MSSQLServer&EvtID=4064&LinkId=20476 BUTTONS: OK TITLE: Connect to Database Engine Cannot connect to SMTECH5\COLLEGEERP. ADDITIONAL INFORMATION: Cannot open user default database. Login failed. Login failed for user 'SMTECH\jangid'. (Microsoft SQL Server, Error: 4064) For help, click: http://go.microsoft.com/fwlink?ProdName=Microsoft+SQL+Server&EvtSrc=MSSQLServer&EvtID=4064&LinkId=20476 BUTTONS: OK this happens on all the pcs in our lab

    Read the article

  • Stored procedure for generic MERGE

    - by GilliVilla
    I have a set of 10 tables in a database (DB1). And there are 10 tables in another database (DB2) with exact same schema on the same SQL Server 2008 R2 database server machine. The 10 tables in DB1 are frequently updated with data. I intend to write a stored procedure that would run once every day for synchronizing the 10 tables in DB1 with DB2. The stored procedure would make use of the MERGE statement. Now, my aim is to make this as generic and parametrized as possible. That is, accommodate for more tables down the line... and accommodate different source and target DB names. Definitely no hard coding is intended. This is my algorithm so far: Have the database names as parameters Have the first query within the stored procedure... result in giving the names of the 10 tables from a lookup table (this can be 10, 20 or whatever) Have a generic MERGE statement that does the sync for each of the above set of tables (based on primary key?) This is where I need more inputs on. What is the best way to achieve this stored procedure? SQL syntax would be helpful.

    Read the article

  • Mysterious double execution of Click handler after change to Windows 2008 Server

    - by mjn
    After moving a Delphi 2009 application from a Windows 2003 / Citrix environment to a 64 bit Windows 2008 R2 environment (users now use RDP instead of Citrix), there are frequent runtime errors which are caused by a double exection of a menu item click handler. The first call of the event handler opens a modal form. Then the same event handler is triggered again and thus a runtime exception occurs since the visible form can not be made modal. The madExcept stack trace looks like this: main thread ($2dc): 004ffa88 +06c Ladelist.exe Forms TCustomForm.ShowModal 0052f4ff +0bb Ladelist.exe DB TDataSet.SetActive 008fc9a1 +089 Ladelist.exe u_ladeli 928 +16 TForm1.EditLoadingList 008fadec +070 Ladelist.exe u_ladeli 504 +5 TForm1.OpenLoadingListClick <----- 2 004d6e27 +0a7 Ladelist.exe Menus TMenuItem.Click 004d857f +0ef Ladelist.exe Menus DoClick 004d866b +087 Ladelist.exe Menus TMenu.IsShortCut 005001c1 +04d Ladelist.exe Forms TCustomForm.IsShortCut 004e8dc0 +068 Ladelist.exe Controls TWinControl.IsMenuKey 004e8f89 +011 Ladelist.exe Controls TWinControl.CNSysKeyDown 004e247e +2d2 Ladelist.exe Controls TControl.WndProc 004e6983 +513 Ladelist.exe Controls TWinControl.WndProc 004fb5e8 +594 Ladelist.exe Forms TCustomForm.WndProc 004e20a4 +024 Ladelist.exe Controls TControl.Perform 004856e0 +014 Ladelist.exe Classes StdWndProc 004e609c +02c Ladelist.exe Controls TWinControl.MainWndProc 004856e0 +014 Ladelist.exe Classes StdWndProc 775b00e3 +02b ntdll.dll KiUserCallbackDispatcher 008fc9a1 +089 Ladelist.exe u_ladeli 928 +16 TForm1.EditLoadingList 008fadec +070 Ladelist.exe u_ladeli 504 +5 TForm1.OpenLoadingListClick <----- 1 004d6e27 +0a7 Ladelist.exe Menus TMenuItem.Click 004d857f +0ef Ladelist.exe Menus DoClick 004d866b +087 Ladelist.exe Menus TMenu.IsShortCut 005001c1 +04d Ladelist.exe Forms TCustomForm.IsShortCut 004e8dc0 +068 Ladelist.exe Controls TWinControl.IsMenuKey 004e8e0d +01d Ladelist.exe Controls TWinControl.CNKeyDown 004e247e +2d2 Ladelist.exe Controls TControl.WndProc 004e6983 +513 Ladelist.exe Controls TWinControl.WndProc 004fb5e8 +594 Ladelist.exe Forms TCustomForm.WndProc 004e20a4 +024 Ladelist.exe Controls TControl.Perform 004e609c +02c Ladelist.exe Controls TWinControl.MainWndProc 004856e0 +014 Ladelist.exe Classes StdWndProc 775b00e3 +02b ntdll.dll KiUserCallbackDispatcher 753c3675 +010 kernel32.dll BaseThreadInitThunk

    Read the article

  • Windows 2008 and wrong BPL loading [SOLVED]

    - by Beto Neto
    I have an application builded with Run-time Packages. When the executable starts it auto loads the required packages (.bpl). Recently we has installed an Windows 2008 R2 server to use as Terminal Services. We maintain some old compiled versions of our application in different paths, like this: c:\app\version_1\common.bpl c:\app\version_1\app.exe c:\app\version_2\common.bpl c:\app\version_2\app.exe Common.bpl is the a run-time package what app.exe depends on. THE PROBLEM: I start "c:\app\version_2\app.exe" and it loads "c:\app\version_2\common.bpl". When I start the "c:\app\version_1\app.exe" it loads the WRONG bpl (from version_2). The path "c:\app\version_2\" isn't at the system search path. At Windows2003 server this problem doesn't occurs. What can I do to solve this? Thanks! I have downloaded the Process Explorer (microsoft sysinternals), and checked the loaded modules of each executable, all they are correct! But I noticed another problem. After start the second version, an entry-not-found-error occurs, telling me what a initialization entry point, of an unit what only exists in one of the versions, could not be found. Something is very strange. The ProcessExplorer is telling me that the process is loading the correct modoles, but when they are running this seems not be happening. Seems the applications are sharing the loaded modules. SOLVED There was a MouseHook using FindVCLWindow, this was generating the AV. Sorry about inconvenience guys, and thanks!

    Read the article

  • Sortie de Microsoft Dynamics NAV 2009 R2, le nouvel ERP de Microsoft pour les PME propose un outil de visualisation très simple et innovant

    Microsoft Dynamics NAV 2009 R2 Le nouvel ERP de Microsoft pour les PME propose un outil de visualisation simple et innovant La gamme des solutions d'entreprise de Microsoft est très complète. Tout comme pour ses licences d'utilisation, il est très facile de s'y perdre. Mais l'avantage de cette gamme réside dans le fait qu'elle couvre nombre de besoins des enterprises. Sa gamme d'ERP (ou PGI pour Progiciel de gestion intégré) ne fait pas exception. Issu de la gamme Dynamics (qui compte également deux CRM), le dernier ERP de Microsoft Dynamics NAV 2009 R2 est la version qui vise les entreprises de 20 à 1...

    Read the article

  • La release RTM SQL Server 2008 R2 disponible pour les abonnées TECHNET et MSDN Pro à partir du 3 mai

    Mise à jour du 26/04/10 Sortie de la release RTM SQL Server 2008 R2 Elle sera disponible pour les abonnées TECHNET et MSDN Pro à partir du 3 mai Microsoft vient d'annoncer l'arrivée de la Release To Manufacturer (RTM) de SQL Server 2008 R2. Cette RTM sera mis à la disposition des abonnées TECHNET et MSDN Pro à partir du 3 mai prochain. Elle sera ensuite téléchargeable pour les autres intéressés à partir du 13 mai. Pour fêter cette sortie, Microsoft, en collaboration avec l'Association Professionnelle pour SQL Server (Professional Association for SQL Server), organisera plus de 85 événements de lancement dans le m...

    Read the article

  • Microsoft annonce une vulnérabilité dans Windows 7 et Windows Server 2008 R2 versions 64 bits qui to

    Microsoft met en garde contre une vulnérabilité de Windows 7 Et Windows Server 2008 R2 : elle touche Aero et les versions 64 bits Dans un bulletin de sécurité, Microsoft met en garde les utilisateurs de Windows 7 et de Windows Server 2008 R2 contre une vulnérabilité récemment découverte dans les versions 64 bits de ces deux OS. La vulnérabilité pourrait permettre l'exécution d'un code arbitraire. Le « pourrait » est important car la dangerosité de la faille semble être assez faible. Néanmoins, deux précautions valent mieux qu'une et Microsoft continue à jour la carte de la transparence (cf. ci-dessous "Lire aussi"). On apprend dans le bulletin de sé...

    Read the article

  • Does Hauppauge WinTV HVR-900 (r2) [USB ID 2040:6502] work with ubuntu 12.04 LTS?

    - by nightfly
    I have this DVB+Analog usb tv tuner Hauppauge WinTV HVR-900 (r2) [USB ID 2040:6502]. This used to work under ubuntu 10.04 LTS. But in 12.04 there seems to be a problem. I have linux-firmware-nonfree and ivtv-utils installed. I am running Ubuntu 12.04.1 LTS 64 bit with all updates installed and the default unity environment. When I run mplayer tv:// -tv driver=v4l2:device=/dev/video1:input=1:norm=PAL I get a solid green screen and no picture. Here input 1 is the composite input of the card. MPlayer svn r34540 (Ubuntu), built with gcc-4.6 (C) 2000-2012 MPlayer Team mplayer: could not connect to socket mplayer: No such file or directory Failed to open LIRC support. You will not be able to use your remote control. Playing tv://. TV file format detected. Selected driver: v4l2 name: Video 4 Linux 2 input author: Martin Olschewski comment: first try, more to come ;-) Selected device: Hauppauge WinTV HVR 900 (R2) Tuner cap: Tuner rxs: Capabilities: video capture VBI capture device tuner audio read/write streaming supported norms: 0 = NTSC; 1 = NTSC-M; 2 = NTSC-M-JP; 3 = NTSC-M-KR; 4 = NTSC-443; 5 = PAL; 6 = PAL-BG; 7 = PAL-H; 8 = PAL-I; 9 = PAL-DK; 10 = PAL-M; 11 = PAL-N; 12 = PAL-Nc; 13 = PAL-60; 14 = SECAM; 15 = SECAM-B; 16 = SECAM-G; 17 = SECAM-H; 18 = SECAM-DK; 19 = SECAM-L; 20 = SECAM-Lc; inputs: 0 = Television; 1 = Composite1; 2 = S-Video; Current input: 1 Current format: YUYV v4l2: current audio mode is : MONO v4l2: ioctl set format failed: Invalid argument v4l2: ioctl set format failed: Invalid argument v4l2: ioctl set format failed: Invalid argument v4l2: ioctl query control failed: Invalid argument v4l2: ioctl query control failed: Invalid argument v4l2: ioctl query control failed: Invalid argument v4l2: ioctl query control failed: Invalid argument Failed to open VDPAU backend libvdpau_nvidia.so: cannot open shared object file: No such file or directory [vdpau] Error when calling vdp_device_create_x11: 1 ========================================================================== Opening video decoder: [raw] RAW Uncompressed Video Movie-Aspect is undefined - no prescaling applied. VO: [xv] 640x480 = 640x480 Packed YUY2 Selected video codec: [rawyuy2] vfm: raw (RAW YUY2) ========================================================================== Audio: no sound Starting playback... v4l2: select timeout V: 0.0 2/ 2 ??% ??% ??,?% 0 0 v4l2: select timeout V: 0.0 4/ 4 ??% ??% ??,?% 0 0 v4l2: select timeout V: 0.0 6/ 6 ??% ??% ??,?% 0 0 v4l2: select timeout v4l2: 0 frames successfully processed, 1 frames dropped. Exiting... (Quit) Here is the dmesg of the card when plugged in.. [12742.228097] usb 1-4: new high-speed USB device number 3 using ehci_hcd [12742.367289] em28xx: New device WinTV HVR-900 @ 480 Mbps (2040:6502, interface 0, class 0) [12742.367296] em28xx: Audio Vendor Class interface 0 found [12742.367585] em28xx #0: chip ID is em2882/em2883 [12742.550086] em28xx #0: i2c eeprom 00: 1a eb 67 95 40 20 02 65 d0 12 5c 03 82 1e 6a 18 [12742.550104] em28xx #0: i2c eeprom 10: 00 00 24 57 66 07 01 00 00 00 00 00 00 00 00 00 [12742.550120] em28xx #0: i2c eeprom 20: 46 00 01 00 f0 10 02 00 b8 00 00 00 5b e0 00 00 [12742.550135] em28xx #0: i2c eeprom 30: 00 00 20 40 20 6e 02 20 10 01 01 01 00 00 00 00 [12742.550150] em28xx #0: i2c eeprom 40: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 [12742.550165] em28xx #0: i2c eeprom 50: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 [12742.550181] em28xx #0: i2c eeprom 60: 00 00 00 00 00 00 00 00 00 00 18 03 34 00 30 00 [12742.550196] em28xx #0: i2c eeprom 70: 32 00 37 00 38 00 32 00 33 00 39 00 30 00 31 00 [12742.550211] em28xx #0: i2c eeprom 80: 00 00 1e 03 57 00 69 00 6e 00 54 00 56 00 20 00 [12742.550226] em28xx #0: i2c eeprom 90: 48 00 56 00 52 00 2d 00 39 00 30 00 30 00 00 00 [12742.550241] em28xx #0: i2c eeprom a0: 84 12 00 00 05 50 1a 7f d4 78 23 fa fd d0 28 89 [12742.550257] em28xx #0: i2c eeprom b0: ff 00 00 00 04 84 0a 00 01 01 20 77 00 40 1d b7 [12742.550272] em28xx #0: i2c eeprom c0: 13 f0 74 02 01 00 01 79 63 00 00 00 00 00 00 00 [12742.550287] em28xx #0: i2c eeprom d0: 84 12 00 00 05 50 1a 7f d4 78 23 fa fd d0 28 89 [12742.550302] em28xx #0: i2c eeprom e0: ff 00 00 00 04 84 0a 00 01 01 20 77 00 40 1d b7 [12742.550317] em28xx #0: i2c eeprom f0: 13 f0 74 02 01 00 01 79 63 00 00 00 00 00 00 00 [12742.550334] em28xx #0: EEPROM ID= 0x9567eb1a, EEPROM hash = 0x2bbf3bdd [12742.550338] em28xx #0: EEPROM info: [12742.550340] em28xx #0: AC97 audio (5 sample rates) [12742.550343] em28xx #0: 500mA max power [12742.550346] em28xx #0: Table at 0x24, strings=0x1e82, 0x186a, 0x0000 [12742.552590] em28xx #0: Identified as Hauppauge WinTV HVR 900 (R2) (card=18) [12742.555516] tveeprom 15-0050: Hauppauge model 65018, rev B2C0, serial# 1292061 [12742.555523] tveeprom 15-0050: tuner model is Xceive XC3028 (idx 120, type 71) [12742.555529] tveeprom 15-0050: TV standards PAL(B/G) PAL(I) PAL(D/D1/K) ATSC/DVB Digital (eeprom 0xd4) [12742.555534] tveeprom 15-0050: audio processor is None (idx 0) [12742.555537] tveeprom 15-0050: has radio [12742.570297] tuner 15-0061: Tuner -1 found with type(s) Radio TV. [12742.570327] xc2028 15-0061: creating new instance [12742.570332] xc2028 15-0061: type set to XCeive xc2028/xc3028 tuner [12742.573685] xc2028 15-0061: Loading 80 firmware images from xc3028-v27.fw, type: xc2028 firmware, ver 2.7 [12742.624056] xc2028 15-0061: Loading firmware for type=BASE MTS (5), id 0000000000000000. [12744.126591] xc2028 15-0061: Loading firmware for type=MTS (4), id 000000000000b700. [12744.153586] xc2028 15-0061: Loading SCODE for type=MTS LCD NOGD MONO IF SCODE HAS_IF_4500 (6002b004), id 000000000000b700. [12744.280963] Registered IR keymap rc-hauppauge [12744.281151] input: em28xx IR (em28xx #0) as /devices/pci0000:00/0000:00:1a.7/usb1/1-4/rc/rc1/input10 [12744.281541] rc1: em28xx IR (em28xx #0) as /devices/pci0000:00/0000:00:1a.7/usb1/1-4/rc/rc1 [12744.282454] em28xx #0: Config register raw data: 0xd0 [12744.284709] em28xx #0: AC97 vendor ID = 0xffffffff [12744.285829] em28xx #0: AC97 features = 0x6a90 [12744.285832] em28xx #0: Empia 202 AC97 audio processor detected [12744.359211] em28xx #0: v4l2 driver version 0.1.3 [12744.404066] xc2028 15-0061: Loading firmware for type=BASE F8MHZ MTS (7), id 0000000000000000. [12745.915089] MTS (4), id 00000000000000ff: [12745.915100] xc2028 15-0061: Loading firmware for type=MTS (4), id 0000000100000007. [12746.161668] em28xx #0: V4L2 video device registered as video1 [12746.161673] em28xx #0: V4L2 VBI device registered as vbi0 [12746.162845] em28xx-audio.c: probing for em28xx Audio Vendor Class [12746.162848] em28xx-audio.c: Copyright (C) 2006 Markus Rechberger [12746.162851] em28xx-audio.c: Copyright (C) 2007-2011 Mauro Carvalho Chehab [12746.221099] xc2028 15-0061: attaching existing instance [12746.221105] xc2028 15-0061: type set to XCeive xc2028/xc3028 tuner [12746.221109] em28xx #0: em28xx #0/2: xc3028 attached [12746.221113] DVB: registering new adapter (em28xx #0) [12746.221118] DVB: registering adapter 0 frontend 0 (Micronas DRXD DVB-T)... [12746.221869] em28xx #0: Successfully loaded em28xx-dvb [13111.196055] xc2028 15-0061: Loading firmware for type=BASE F8MHZ MTS (7), id 0000000000000000. [13112.720062] MTS (4), id 00000000000000ff: [13112.720072] xc2028 15-0061: Loading firmware for type=MTS (4), id 0000000100000007. [13214.956057] xc2028 15-0061: Loading firmware for type=BASE F8MHZ MTS (7), id 0000000000000000. [13216.479806] MTS (4), id 00000000000000ff: [13216.479816] xc2028 15-0061: Loading firmware for type=MTS (4), id 0000000100000007. [13276.408056] xc2028 15-0061: Loading firmware for type=BASE F8MHZ MTS (7), id 0000000000000000. [13277.932093] MTS (4), id 00000000000000ff: [13277.932104] xc2028 15-0061: Loading firmware for type=MTS (4), id 0000000100000007. [13305.032076] xc2028 15-0061: Loading firmware for type=BASE F8MHZ MTS (7), id 0000000000000000. [13306.556449] MTS (4), id 00000000000000ff: [13306.556460] xc2028 15-0061: Loading firmware for type=MTS (4), id 0000000100000007. [13392.236055] xc2028 15-0061: Loading firmware for type=BASE F8MHZ MTS (7), id 0000000000000000. [13393.760123] MTS (4), id 00000000000000ff: [13393.760133] xc2028 15-0061: Loading firmware for type=MTS (4), id 0000000100000007. [13637.534053] usb 1-4: USB disconnect, device number 3 [13637.534183] em28xx #0: disconnecting em28xx #0 video [13637.560214] em28xx #0: V4L2 device vbi0 deregistered [13637.560335] em28xx #0: V4L2 device video1 deregistered [13637.561237] xc2028 15-0061: destroying instance [13639.772120] usb 1-4: new high-speed USB device number 4 using ehci_hcd [13639.911351] em28xx: New device WinTV HVR-900 @ 480 Mbps (2040:6502, interface 0, class 0) [13639.911357] em28xx: Audio Vendor Class interface 0 found [13639.911637] em28xx #0: chip ID is em2882/em2883 [13640.094262] em28xx #0: i2c eeprom 00: 1a eb 67 95 40 20 02 65 d0 12 5c 03 82 1e 6a 18 [13640.094280] em28xx #0: i2c eeprom 10: 00 00 24 57 66 07 01 00 00 00 00 00 00 00 00 00 [13640.094295] em28xx #0: i2c eeprom 20: 46 00 01 00 f0 10 02 00 b8 00 00 00 5b e0 00 00 [13640.094311] em28xx #0: i2c eeprom 30: 00 00 20 40 20 6e 02 20 10 01 01 01 00 00 00 00 [13640.094326] em28xx #0: i2c eeprom 40: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 [13640.094341] em28xx #0: i2c eeprom 50: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 [13640.094356] em28xx #0: i2c eeprom 60: 00 00 00 00 00 00 00 00 00 00 18 03 34 00 30 00 [13640.094371] em28xx #0: i2c eeprom 70: 32 00 37 00 38 00 32 00 33 00 39 00 30 00 31 00 [13640.094386] em28xx #0: i2c eeprom 80: 00 00 1e 03 57 00 69 00 6e 00 54 00 56 00 20 00 [13640.094401] em28xx #0: i2c eeprom 90: 48 00 56 00 52 00 2d 00 39 00 30 00 30 00 00 00 [13640.094416] em28xx #0: i2c eeprom a0: 84 12 00 00 05 50 1a 7f d4 78 23 fa fd d0 28 89 [13640.094432] em28xx #0: i2c eeprom b0: ff 00 00 00 04 84 0a 00 01 01 20 77 00 40 1d b7 [13640.094447] em28xx #0: i2c eeprom c0: 13 f0 74 02 01 00 01 79 63 00 00 00 00 00 00 00 [13640.094462] em28xx #0: i2c eeprom d0: 84 12 00 00 05 50 1a 7f d4 78 23 fa fd d0 28 89 [13640.094477] em28xx #0: i2c eeprom e0: ff 00 00 00 04 84 0a 00 01 01 20 77 00 40 1d b7 [13640.094492] em28xx #0: i2c eeprom f0: 13 f0 74 02 01 00 01 79 63 00 00 00 00 00 00 00 [13640.094509] em28xx #0: EEPROM ID= 0x9567eb1a, EEPROM hash = 0x2bbf3bdd [13640.094512] em28xx #0: EEPROM info: [13640.094515] em28xx #0: AC97 audio (5 sample rates) [13640.094517] em28xx #0: 500mA max power [13640.094521] em28xx #0: Table at 0x24, strings=0x1e82, 0x186a, 0x0000 [13640.097391] em28xx #0: Identified as Hauppauge WinTV HVR 900 (R2) (card=18) [13640.099617] tveeprom 15-0050: Hauppauge model 65018, rev B2C0, serial# 1292061 [13640.099623] tveeprom 15-0050: tuner model is Xceive XC3028 (idx 120, type 71) [13640.099629] tveeprom 15-0050: TV standards PAL(B/G) PAL(I) PAL(D/D1/K) ATSC/DVB Digital (eeprom 0xd4) [13640.099634] tveeprom 15-0050: audio processor is None (idx 0) [13640.099637] tveeprom 15-0050: has radio [13640.112849] tuner 15-0061: Tuner -1 found with type(s) Radio TV. [13640.112877] xc2028 15-0061: creating new instance [13640.112882] xc2028 15-0061: type set to XCeive xc2028/xc3028 tuner [13640.115930] xc2028 15-0061: Loading 80 firmware images from xc3028-v27.fw, type: xc2028 firmware, ver 2.7 [13640.164057] xc2028 15-0061: Loading firmware for type=BASE MTS (5), id 0000000000000000. [13641.666643] xc2028 15-0061: Loading firmware for type=MTS (4), id 000000000000b700. [13641.693262] xc2028 15-0061: Loading SCODE for type=MTS LCD NOGD MONO IF SCODE HAS_IF_4500 (6002b004), id 000000000000b700. [13641.820765] Registered IR keymap rc-hauppauge [13641.820958] input: em28xx IR (em28xx #0) as /devices/pci0000:00/0000:00:1a.7/usb1/1-4/rc/rc2/input11 [13641.821335] rc2: em28xx IR (em28xx #0) as /devices/pci0000:00/0000:00:1a.7/usb1/1-4/rc/rc2 [13641.822256] em28xx #0: Config register raw data: 0xd0 [13641.824526] em28xx #0: AC97 vendor ID = 0xffffffff [13641.825503] em28xx #0: AC97 features = 0x6a90 [13641.825507] em28xx #0: Empia 202 AC97 audio processor detected [13641.899015] em28xx #0: v4l2 driver version 0.1.3 [13641.944064] xc2028 15-0061: Loading firmware for type=BASE F8MHZ MTS (7), id 0000000000000000. [13643.470765] MTS (4), id 00000000000000ff: [13643.470776] xc2028 15-0061: Loading firmware for type=MTS (4), id 0000000100000007. [13643.717713] em28xx #0: V4L2 video device registered as video1 [13643.717718] em28xx #0: V4L2 VBI device registered as vbi0 [13643.718770] em28xx-audio.c: probing for em28xx Audio Vendor Class [13643.718775] em28xx-audio.c: Copyright (C) 2006 Markus Rechberger [13643.718778] em28xx-audio.c: Copyright (C) 2007-2011 Mauro Carvalho Chehab [13643.777148] xc2028 15-0061: attaching existing instance [13643.777154] xc2028 15-0061: type set to XCeive xc2028/xc3028 tuner [13643.777158] em28xx #0: em28xx #0/2: xc3028 attached [13643.777162] DVB: registering new adapter (em28xx #0) [13643.777167] DVB: registering adapter 0 frontend 0 (Micronas DRXD DVB-T)... [13643.777876] em28xx #0: Successfully loaded em28xx-dvb And here goes the lsmod output lsmod|grep em28xx em28xx_dvb 18579 0 dvb_core 110619 1 em28xx_dvb em28xx_alsa 18305 0 em28xx 109365 2 em28xx_dvb,em28xx_alsa v4l2_common 16454 3 tuner,tvp5150,em28xx videobuf_vmalloc 13589 1 em28xx videobuf_core 26390 2 em28xx,videobuf_vmalloc rc_core 26412 10 rc_hauppauge,ir_lirc_codec,ir_mce_kbd_decoder,ir_sony_decoder,ir_jvc_decoder,ir_rc6_decoder,ir_rc5_decoder,em28xx,ir_nec_decoder snd_pcm 97188 3 em28xx_alsa,snd_hda_intel,snd_hda_codec tveeprom 21249 1 em28xx videodev 98259 5 tuner,tvp5150,em28xx,v4l2_common,uvcvideo snd 78855 14 em28xx_alsa,snd_hda_codec_conexant,snd_hda_intel,snd_hda_codec,snd_hwdep,snd_pcm,snd_rawmidi,snd_seq,snd_timer,snd_seq_device Isn't this driver mainline now? Or this card is not supported? Or the analog functionality is screwed? I need the analog capture working for this card. Please help!

    Read the article

  • Stdin to powershell script

    - by Stefan
    I have a service running that can invoke an external process to modify a text stream before it is returned to the service. The text stream is handed from the service to the external process on stdout and the modified result is read from the service on stdin. The external process (command) can in other words be used as a text "filter". I would like to use a powershell script to modify the text stream. I can successfully launch a script from the service on win 2008r2 using the command "powershell -executionpolicy bypass -noninteractive ./myscript.ps1". I can make the script return text to the service on stdout using the write-host cmdlet. My problem is that I can't find a way to read the text on stdin in the script. Read-host doesn't seem to work as it requires an interactive shell. I would like to avoid writing the stdout from the service to a tmp file and read that file in the script as the service is multithreaded (can launch more than one external command at a time) and tmp file management (locking, unique filenames etc) is not desired. Is this possible or should I use for example Perl for this? Powershell seems compelling as it is preinstalled on all my win 2008 machines.

    Read the article

  • Loading any MVC page fails with the error "An item with the same key has already been added."

    - by MajorRefactoring
    I am having an intermittent issue that is appearing on one server only, and is causing all MVC pages to fail to load with the error "An item with the same key has already been added." Restarting the application pool fixes the issue, but until then, loading any mvc page throws the following exception: Event code: 3005 Event message: An unhandled exception has occurred. Event time: 10/11/2012 08:09:24 Event time (UTC): 10/11/2012 08:09:24 Event ID: d76264aedc4241d4bce9247692510466 Event sequence: 6407 Event occurrence: 30 Event detail code: 0 Application information: Application domain: /LM/W3SVC/21/ROOT-2-129969647741292058 Trust level: Full Application Virtual Path: / Application Path: d:\websites\SiteAndAppPoolName\ Machine name: UKSERVER Process information: Process ID: 6156 Process name: w3wp.exe Account name: IIS APPPOOL\SiteAndAppPoolName Exception information: Exception type: ArgumentException Exception message: An item with the same key has already been added. Server stack trace: at System.Collections.Generic.Dictionary`2.Insert(TKey key, TValue value, Boolean add) at System.Linq.Enumerable.ToDictionary[TSource,TKey,TElement](IEnumerable`1 source, Func`2 keySelector, Func`2 elementSelector, IEqualityComparer`1 comparer) at System.Web.WebPages.Scope.WebConfigScopeDictionary.<>c__DisplayClass4.<.ctor>b__0() at System.Lazy`1.CreateValue() Exception rethrown at [0]: at System.Lazy`1.get_Value() at System.Web.WebPages.Scope.WebConfigScopeDictionary.TryGetValue(Object key, Object& value) at System.Web.Mvc.ViewContext.ScopeGet[TValue](IDictionary`2 scope, String name, TValue defaultValue) at System.Web.Mvc.ViewContext.ScopeCache.Get(IDictionary`2 scope, HttpContextBase httpContext) at System.Web.Mvc.ViewContext.GetClientValidationEnabled(IDictionary`2 scope, HttpContextBase httpContext) at System.Web.Mvc.Html.FormExtensions.FormHelper(HtmlHelper htmlHelper, String formAction, FormMethod method, IDictionary`2 htmlAttributes) at System.Web.Mvc.Html.FormExtensions.BeginForm(HtmlHelper htmlHelper, String actionName, String controllerName) at ASP._Page_Views_Dashboard_Functions_BookingQuickLookup_cshtml.Execute() in d:\Websites\SiteAndAppPoolName\Views\Dashboard\Functions\BookingQuickLookup.cshtml:line 3 at System.Web.WebPages.WebPageBase.ExecutePageHierarchy() at System.Web.Mvc.WebViewPage.ExecutePageHierarchy() at System.Web.WebPages.WebPageBase.ExecutePageHierarchy(WebPageContext pageContext, TextWriter writer, WebPageRenderingBase startPage) at System.Web.Mvc.Html.PartialExtensions.Partial(HtmlHelper htmlHelper, String partialViewName, Object model, ViewDataDictionary viewData) at ASP._Page_Views_Dashboard_Functions_cshtml.Execute() in d:\Websites\SiteAndAppPoolName\Views\Dashboard\Functions.cshtml:line 5 at System.Web.WebPages.WebPageBase.ExecutePageHierarchy() at System.Web.Mvc.WebViewPage.ExecutePageHierarchy() at System.Web.WebPages.WebPageBase.ExecutePageHierarchy(WebPageContext pageContext, TextWriter writer, WebPageRenderingBase startPage) at System.Web.Mvc.Html.RenderPartialExtensions.RenderPartial(HtmlHelper htmlHelper, String partialViewName, Object model) at ASP._Page_Views_Dashboard_Index_cshtml.Execute() in d:\Websites\SiteAndAppPoolName\Views\Dashboard\Index.cshtml:line 9 at System.Web.WebPages.WebPageBase.ExecutePageHierarchy() at System.Web.Mvc.WebViewPage.ExecutePageHierarchy() at System.Web.WebPages.WebPageBase.ExecutePageHierarchy(WebPageContext pageContext, TextWriter writer, WebPageRenderingBase startPage) at System.Web.Mvc.ViewResultBase.ExecuteResult(ControllerContext context) at System.Web.Mvc.ControllerActionInvoker.<>c__DisplayClass1c.<InvokeActionResultWithFilters>b__19() at System.Web.Mvc.ControllerActionInvoker.InvokeActionResultFilter(IResultFilter filter, ResultExecutingContext preContext, Func`1 continuation) at System.Web.Mvc.ControllerActionInvoker.InvokeActionResultFilter(IResultFilter filter, ResultExecutingContext preContext, Func`1 continuation) at System.Web.Mvc.ControllerActionInvoker.InvokeActionResultWithFilters(ControllerContext controllerContext, IList`1 filters, ActionResult actionResult) at System.Web.Mvc.ControllerActionInvoker.InvokeAction(ControllerContext controllerContext, String actionName) at System.Web.Mvc.Controller.ExecuteCore() at System.Web.Mvc.ControllerBase.Execute(RequestContext requestContext) at System.Web.Mvc.MvcHandler.<>c__DisplayClass6.<>c__DisplayClassb.<BeginProcessRequest>b__5() at System.Web.Mvc.Async.AsyncResultWrapper.<>c__DisplayClass1.<MakeVoidDelegate>b__0() at System.Web.Mvc.MvcHandler.<>c__DisplayClasse.<EndProcessRequest>b__d() at System.Web.HttpApplication.CallHandlerExecutionStep.System.Web.HttpApplication.IExecutionStep.Execute() at System.Web.HttpApplication.ExecuteStep(IExecutionStep step, Boolean& completedSynchronously) Request information: Request URL: http://SiteAndAppPoolName.spawtz.com/Dashboard Request path: /Dashboard User host address: 86.164.135.41 User: Is authenticated: False Authentication Type: Thread account name: IIS APPPOOL\SiteAndAppPoolName Thread information: Thread ID: 17 Thread account name: IIS APPPOOL\SiteAndAppPoolName Is impersonating: False Stack trace: at System.Lazy`1.get_Value() at System.Web.WebPages.Scope.WebConfigScopeDictionary.TryGetValue(Object key, Object& value) at System.Web.Mvc.ViewContext.ScopeGet[TValue](IDictionary`2 scope, String name, TValue defaultValue) at System.Web.Mvc.ViewContext.ScopeCache.Get(IDictionary`2 scope, HttpContextBase httpContext) at System.Web.Mvc.ViewContext.GetClientValidationEnabled(IDictionary`2 scope, HttpContextBase httpContext) at System.Web.Mvc.Html.FormExtensions.FormHelper(HtmlHelper htmlHelper, String formAction, FormMethod method, IDictionary`2 htmlAttributes) at System.Web.Mvc.Html.FormExtensions.BeginForm(HtmlHelper htmlHelper, String actionName, String controllerName) at ASP._Page_Views_Dashboard_Functions_BookingQuickLookup_cshtml.Execute() in d:\Websites\SiteAndAppPoolName\Views\Dashboard\Functions\BookingQuickLookup.cshtml:line 3 at System.Web.WebPages.WebPageBase.ExecutePageHierarchy() at System.Web.Mvc.WebViewPage.ExecutePageHierarchy() at System.Web.WebPages.WebPageBase.ExecutePageHierarchy(WebPageContext pageContext, TextWriter writer, WebPageRenderingBase startPage) at System.Web.Mvc.Html.PartialExtensions.Partial(HtmlHelper htmlHelper, String partialViewName, Object model, ViewDataDictionary viewData) at ASP._Page_Views_Dashboard_Functions_cshtml.Execute() in d:\Websites\SiteAndAppPoolName\Views\Dashboard\Functions.cshtml:line 5 at System.Web.WebPages.WebPageBase.ExecutePageHierarchy() at System.Web.Mvc.WebViewPage.ExecutePageHierarchy() at System.Web.WebPages.WebPageBase.ExecutePageHierarchy(WebPageContext pageContext, TextWriter writer, WebPageRenderingBase startPage) at System.Web.Mvc.Html.RenderPartialExtensions.RenderPartial(HtmlHelper htmlHelper, String partialViewName, Object model) at ASP._Page_Views_Dashboard_Index_cshtml.Execute() in d:\Websites\SiteAndAppPoolName\Views\Dashboard\Index.cshtml:line 9 at System.Web.WebPages.WebPageBase.ExecutePageHierarchy() at System.Web.Mvc.WebViewPage.ExecutePageHierarchy() at System.Web.WebPages.WebPageBase.ExecutePageHierarchy(WebPageContext pageContext, TextWriter writer, WebPageRenderingBase startPage) at System.Web.Mvc.ViewResultBase.ExecuteResult(ControllerContext context) at System.Web.Mvc.ControllerActionInvoker.<>c__DisplayClass1c.<InvokeActionResultWithFilters>b__19() at System.Web.Mvc.ControllerActionInvoker.InvokeActionResultFilter(IResultFilter filter, ResultExecutingContext preContext, Func`1 continuation) at System.Web.Mvc.ControllerActionInvoker.InvokeActionResultFilter(IResultFilter filter, ResultExecutingContext preContext, Func`1 continuation) at System.Web.Mvc.ControllerActionInvoker.InvokeActionResultWithFilters(ControllerContext controllerContext, IList`1 filters, ActionResult actionResult) at System.Web.Mvc.ControllerActionInvoker.InvokeAction(ControllerContext controllerContext, String actionName) at System.Web.Mvc.Controller.ExecuteCore() at System.Web.Mvc.ControllerBase.Execute(RequestContext requestContext) at System.Web.Mvc.MvcHandler.<>c__DisplayClass6.<>c__DisplayClassb.<BeginProcessRequest>b__5() at System.Web.Mvc.Async.AsyncResultWrapper.<>c__DisplayClass1.<MakeVoidDelegate>b__0() at System.Web.Mvc.MvcHandler.<>c__DisplayClasse.<EndProcessRequest>b__d() at System.Web.HttpApplication.CallHandlerExecutionStep.System.Web.HttpApplication.IExecutionStep.Execute() at System.Web.HttpApplication.ExecuteStep(IExecutionStep step, Boolean& completedSynchronously) Custom event details: As mentioned, it's every MVC action that throws this error until the app pool is restarted, and the error seems to be occurring in System.Web.WebPages.Scope.WebConfigScopeDictionary.TryGetValue(Object key, Object& value) Has anyone seen this issue before? It's only happening on this server, on any of the app pools on the server (not confined to this one) and an app pool restart sorts it. Any help much appreciated. Cheers, Matthew

    Read the article

  • How to select the top n from a union of two queries where the resulting order needs to be ranked by individual query?

    - by Jedidja
    Let's say I have a table with usernames: Id | Name ----------- 1 | Bobby 20 | Bob 90 | Bob 100 | Joe-Bob 630 | Bobberino 820 | Bob Junior I want to return a list of n matches on name for 'Bob' where the resulting set first contains exact matches followed by similar matches. I thought something like this might work SELECT TOP 4 a.* FROM ( SELECT * from Usernames WHERE Name = 'Bob' UNION SELECT * from Usernames WHERE Name LIKE '%Bob%' ) AS a but there are two problems: It's an inefficient query since the sub-select could return many rows (looking at the execution plan shows a join happening before top) (Almost) more importantly, the exact match(es) will not appear first in the results since the resulting set appears to be ordered by primary key. I am looking for a query that will return (for TOP 4) Id | Name --------- 20 | Bob 90 | Bob (and then 2 results from the LIKE query, e.g. 1 Bobby and 100 Joe-Bob) Is this possible in a single query?

    Read the article

  • SQLCLR using the wrong version of the .NET Framework

    - by Tobias Rundbom
    During a recent restart of our development server the SQL Server started using .NET 4.0 for the SQLCLR. This means that nothing using the CLR in SQL works, or at least that's my understanding by reading these sources: http://software.intel.com/en-us/blogs/2009/10/16/sql-server-2008-sqlclr-net-framework-version/ www.sqlskills.com/BLOGS/BOBB/post/On-SQL-Server-and-NET-40.aspx All we get are error messages of this type: Msg 6517, Level 16, State 1, Line 1 Failed to create AppDomain "xxx.dbo[ddl].3". Method's type signature is not Interop compatible. Does anyone know how to solve this or how we can force SQL Server CLR to use an earlier version of the Framework?

    Read the article

  • Setting Sql server security rights for multiple situations

    - by DanDan
    We have an application which uses an instance of Sql Server locally for its backend storage. The administrator windows login has had its sysadmin right revoked, and instead two sql logins have been created; one for the application with a secret password and one read only login we let users view the raw data with. This was working fine until we moved on FileStreams, which requires intergrated windows authentication. So now the sql server logins must be replaced. As a result, I am now reviewing all of our logins but I am not sure how it is possible. It seems that the application needs full read/write access, yet I still need to lock down writing to the tables so the user cannot login into the database and delete data randomly. Does anyone have any tips for setting multiple levels of security using intergrated windows logins, or can you direct me to any further reading? Some answers can also be found on serverfault: http://serverfault.com/questions/138763/setting-sql-server-security-rights-for-multiple-situations

    Read the article

  • Alter View not recognizing column

    - by Chris
    I have scripts for adding columns to tables which worked. When I run scripts to alter views with the new column the script fails because the columns are not recognized Msg 207, Level 16, State 1, Procedure UniqueTempDispositions, Line 76 Invalid column name 'servicerequestid'. Msg 207, Level 16, State 1, Procedure UniqueTempDispositions, Line 47 Invalid column name 'servicerequestid'. Msg 207, Level 16, State 1, Procedure MergeDispositions, Line 54 Invalid column name 'ServiceRequestID'. Msg 207, Level 16, State 1, Procedure NonPIICachedDispositions, Line 18 Invalid column name 'ServiceRequestID'. Any reason why? Am I missing something? I've started and stopped the server, I've relogged in to no avail.

    Read the article

  • Issue Calculating from Rows and Columns(Summing two columns with the third of a different row)

    - by vstsdev
    With reference to my previous question Adding columns resulting from GROUP BY clause SELECT AcctId,Date, Sum(CASE WHEN DC = 'C' THEN TrnAmt ELSE 0 END) AS C, Sum(CASE WHEN DC = 'D' THEN TrnAmt ELSE 0 END) AS D FROM Table1 where AcctId = '51' GROUP BY AcctId,Date ORDER BY AcctId,Date I executed the above query and got my desired result.. AcctId Date C D 51 2012-12-04 15000 0 51 2012-12-05 150000 160596 51 2012-12-06 600 0 now I have a another operation to do on the same query i.e. I need the result to be like this AcctId Date Result 51 2012-12-04 (15000-0)-> 15000 51 2012-12-05 (150000-160596) + (15000->The first value) 4404 51 2012-12-06 600-0 +(4404 ->The calculated 2nd value) 5004 Is it possible with the same query??.

    Read the article

  • Query gives an unsorted result set when run from stored procedure using CTE

    - by irtizaur
    I am trying to create a paging query using CTE. It works fine when I execute it from Microsoft SQL Server Management Studio Query Editor. And the result set is perfectly sorted as I want. But when I modify it for a stored procedure it gives me a unsorted result and I don't have any clue why. Here is my Query, with items as ( select ROW_NUMBER() over (order by create_time desc) number , i.item_name item_name , i.create_time create_time , c.category_name category_name , i.category_id category_id from cb_item i, cb_category c where i.category_id = c.category_id and c.category_id = '4E5248FE-05DD-4D01-ABBB-80C6E3BA5CDA' ) select item_name , create_time , category_name , category_id from items where number between 1 and 25 And this is the Stored Procedure Version, create procedure ItemPage @category_id uniqueidentifier , @from int , @to int , @sortby nvarchar(50) as begin with items as ( select ROW_NUMBER() over (order by @sortby) number , i.item_name item_name , i.create_time create_time , c.category_name category_name , i.category_id category_id from cb_item i, cb_category c where i.category_id = c.category_id and c.category_id = @category_id ) select item_name , create_time , category_name , category_id from items where number between @from and @to end exec itempage '4E5248FE-05DD-4D01-ABBB-80C6E3BA5CDA' , 1, 25, 'create_time desc' The first one gives me sorted result but procedure gives me unsorted result. I don't know why?

    Read the article

  • Web App Server hardware question. Which configuration?

    - by JBeckton
    I am pricing some new servers and I am not sure which configuration to get. The server will be running some web applications for our company. Some of them are ASP.Net sites and some are ColdFusion. The OS will be Win Server 2008 Web or Standard Edition. Do I need 2 processors or will a single quad core handle it? Xeon multi core Hyperthreading or non Hyperthreading? I am going 64bit so I can go higher than 4 Gigs of Ram. I am shopping at Dell and there are so many options, i do not want to get too much hardware and not use half of it because that would be a waste of money and I do not want to get too little and have to ask for more money to upgrade it later.

    Read the article

  • Moving files between Windows computers without creating network shares

    - by mavnn
    What's needed: To move several directories between two Windows 2008 servers on a regular basis. Due to security requirements, neither server is supposed to have network shares set up or extraneous software installed. What's available: Administrator access to both machines (including remote desktop access if that helps). A third machine with: Visual Studio 2010 Cygwin Bonus extras The script that does the rest of the work (apart from moving the files) is currently written in F#, but any .net/command line based solution would be fine.

    Read the article

  • Can I combine values from multiple rows in another table into multiple columns of one row using SQL?

    - by Jordi
    I have two tables: T1: | M_ID | P_ID1 | P_ID2 | rest of T1 columns | | 0 | 0 | 1 | ... | | 1 | 2 | 3 | ... | T2: | P_ID | Type | A | B | | 0 | 1 | a | e | | 1 | 2 | b | f | | 2 | 1 | c | g | | 3 | 2 | d | h | Now, I want to have a query that selects this: | M_ID | P_1a | P_1b | P_2a | P_2b | rest of T1 columns | | 0 | a | e | b | f | ... | | 1 | c | g | c | h | ... | So, in words: I want to select all columns from T1, but I want to replace P_ID1 with the columns from T2, where the P_ID is equal to P_ID1, and the type is 1, and basically the same for P_ID2. I can obviously get the information I need with multiple queries, but I was wondering if there is a way that I can do this with one query. Any ideas? I'm currently using SQL Server 2008r2, but I'd also be interested in solutions for other database software. Thanks for the help!

    Read the article

  • return 0 with sql query instead of nothing

    - by user1202606
    How do I return a 0 with as Responses with the PossibleAnswerText if count is 0? Right now it won't return anything. select COUNT(sr.Id) AS 'Responses', qpa.PossibleAnswerText from CaresPlusParticipantSurvey.QuestionPossibleAnswer as qpa join CaresPlusParticipantSurvey.SurveyResponse as sr on sr.QuestionPossibleAnswerId = qpa.Id where sr.QuestionPossibleAnswerId = 116 GROUP BY qpa.PossibleAnswerText

    Read the article

  • SQL Server 2008 vs 2005 udf xml perfomance problem.

    - by user344495
    Ok we have a simple udf that takes a XML integer list and returns a table: CREATE FUNCTION [dbo].[udfParseXmlListOfInt] ( @ItemListXml XML (dbo.xsdListOfInteger) ) RETURNS TABLE AS RETURN ( --- parses the XML and returns it as an int table --- SELECT ListItems.ID.value('.','INT') AS KeyValue FROM @ItemListXml.nodes('//list/item') AS ListItems(ID) ) In a stored procedure we create a temp table using this UDF INSERT INTO @JobTable (JobNumber, JobSchedID, JobBatID, StoreID, CustID, CustDivID, BatchStartDate, BatchEndDate, UnavailableFrom) SELECT JOB.JobNumber, JOB.JobSchedID, ISNULL(JOB.JobBatID,0), STO.StoreID, STO.CustID, ISNULL(STO.CustDivID,0), AVL.StartDate, AVL.EndDate, ISNULL(AVL.StartDate, DATEADD(day, -8, GETDATE())) FROM dbo.udfParseXmlListOfInt(@JobNumberList) TMP INNER JOIN dbo.JobSchedule JOB ON (JOB.JobNumber = TMP.KeyValue) INNER JOIN dbo.Store STO ON (STO.StoreID = JOB.StoreID) INNER JOIN dbo.JobSchedEvent EVT ON (EVT.JobSchedID = JOB.JobSchedID AND EVT.IsPrimary = 1) LEFT OUTER JOIN dbo.Availability AVL ON (AVL.AvailTypID = 5 AND AVL.RowID = JOB.JobBatID) ORDER BY JOB.JobSchedID; For a simple list of 10 JobNumbers in SQL2005 this returns in less than 1 second, in 2008 this run against the exact same data returns in 7 min. This is on a much faster machine with more memory. Any ideas?

    Read the article

  • SQL Find duplicate sets

    - by Aheho
    given this Schema: table tblSET SetID int PK SetName nvarchar(100) Table tblSetItem SetID int PK ItemID int PK tblSetItem.SetID is a FK into the tblSet Table. Some data: tblSet SetID SetName 1 Red 2 Blue 3 Maroon 4 Yellow 5 Sky tblSetItem SetID ItemID 1 100 1 101 2 100 2 108 2 109 3 100 3 101 4 101 4 108 4 109 4 110 5 100 5 108 5 109 I'd like a way to identify which sets contain the same items. In the example above Red and Maroon contain the same items (100,101) and Blue and Sky contain the same values (100,108,109) Is there a sql query which would provide this answer?

    Read the article

  • sql query where parameters null not null

    - by Laziale
    I am trying to do a sql query and to build the where condition dynamically depending if the parameters are null or no. I have something like this: SELECT tblOrder.ProdOrder, tblOrder.Customer FROM tblOrder CASE WHEN @OrderId IS NOT NULL THEN WHERE tblOrder.OrderId = @OrderId ELSE END CASE WHEN @OrderCustomer IS NOT NULL THEN AND tblOrder.OrderCustomer = @OrderCustomer ELSE END END This doesn't work, but this is just a small prototype how to assemble the query, so if the orderid is not null include in the where clause, or if the ordercustomer is not null include in the where clause. But I see problem here, for example if the ordercustomer is not null but the orderid is null, there will be error because the where keyword is not included. Any advice how I can tackle this problem. Thanks in advance, Laziale

    Read the article

  • SQL Server to manage ASP.NET sessions doesn't work

    - by windforceus
    I follow the direction in here How to configure SQL Server to manage ASP.NET sessions to create ASPState db. I have 2 web application in IIS 7. In IIS web application setting, i go to "Session State" and set session state as "SQL Server" and provide connection string. In each web application web.config, i add <sessionState mode="SQLServer" allowCustomSqlDatabase="false" sqlConnectionString="data source=server;user id=user;password=password" cookieless="false" timeout="7200" /> I create a session , Session["Data"] = "test" in Web App A and go to Web App B in the same browser to print it Response.Write(Session["Data"]); It shows NOTHING. I can see there are data in table : ASPStateTempApplications and ASPStateTempSessions under ASPState Database. Also, i dont see any error in event log. Can anyone think anything i may do wrong? Thanks!!

    Read the article