Search Results

Search found 4236 results on 170 pages for 'satellite assembly'.

Page 69/170 | < Previous Page | 65 66 67 68 69 70 71 72 73 74 75 76  | Next Page >

  • ASP.NET - Accessing copied content

    - by James Kolpack
    I have a class library project which contains some content files configured with the "Copy if newer" copy build action. This results in the files being copied to a folder under ...\bin\ for every project in the solution. In this same solution, I've got a ASP.NET web project (which is MVC, by the way). In the library I have a static constructor load the files into data structures accessible by the web project. Previously I've been including the content as an embedded resource. I now need to be able to replace them without recompiling. I want to access the data in three different contexts: Unit testing the library assembly Debugging the web application Hosting the site in IIS For unit testing, Environment.CurrentDirectory points to a path containing the copied content. When debugging however, it points to C:\Program Files\Microsoft Visual Studio 9.0\Common7\IDE. I've also looked at Assembly.GetExecutingAssembly().Location which points to C:\Windows\Microsoft.NET\Framework\v2.0.50727\Temporary ASP.NET Files\root\c44f9da4\9238ccc\assembly\dl3\eb4c23b4\9bd39460_f7d4ca01\. What I need is to the physical location of the webroot \bin folder, but since I'm in a static constructor in the library project, I don't have access to a Request.PhysicalApplicationPath. Is there some other environment variable or structure where I can always find my "Copy if newer" files?

    Read the article

  • How can I invoke a .Net DLL from a LabView 6.1 VI?

    - by tw1k
    I work in a manufacturing company that uses LabView for testing the devices we make. Most of the test engineers are using 7.1 which can natively reference a .Net assembly. However, there is a group that is stuck on LabView 6.1. I would like for them to be able to use my .Net assembly which is basically a proxy to some web services. I have created a test assembly that is nothing more than Hello World, and I'm trying to consume it in a VI. I made it COM visible, and registered it with regasm.exe and created a type library, which I'm not sure I need. I can see it in Visual Studio in the list of COM objects when I open the Add Reference window, so I know it's registered properly. I'm very unfamiliar with VI's. I'm only looking at it because no one I have spoken to in manufacturing knows anything about invoking a COM object in a VI. I'm basically looking for some names of controls or menu options to get the test engineers pointed in the right direction. I did a bunch of web searching on Google and the NI forums, but didn't find much. Alternatively, would it be easier to write a C or C++ DLL that acts as a proxy to my .Net DLL? Or is there a simple way to invoke a web service from a VI? That might obviate the need for a DLL altogether. I'm currently reading through this document from NI for help, but it obviously knows nothing about .Net and might not be able to help me choose the best path forward.

    Read the article

  • When is a method eligible to be inlined by the CLR?

    - by Ani
    I've observed a lot of "stack-introspective" code in applications, which often implicitly rely on their containing methods not being inlined for their correctness. Such methods commonly involve calls to: MethodBase.GetCurrentMethod Assembly.GetCallingAssembly Assembly.GetExecutingAssembly Now, I find the information surrounding these methods to be very confusing. I've heard that the run-time will not inline a method that calls GetCurrentMethod, but I can't find any documentation to that effect. I've seen posts on StackOverflow on several occasions, such as this one, indicating the CLR does not inline cross-assembly calls, but the GetCallingAssembly documentation strongly indicates otherwise. There's also the much-maligned [MethodImpl(MethodImpOptions.NoInlining)], but I am unsure if the CLR considers this to be a "request" or a "command." Note that I am asking about inlining eligibility from the standpoint of contract, not about when current implementations of the JITter decline to consider methods because of implementation difficulties, or about when the JITter finally ends up choosing to inline an eligible method after assessing the trade-offs. I have read this and this, but they seem to be more focused on the last two points (there are passing mentions of MethodImpOptions.NoInlining and "exotic IL instructions", but these seem to be presented as heuristics rather than as obligations). When is the CLR allowed to inline?

    Read the article

  • Why do .NET developers offer 32-bit/64-bit versions of .NET assemblies?

    - by Tyler
    Evey now and then I see both x86 and x64 versions of a .NET assembly. Consider the following web part for SharePoint. Why wouldn't the developer just offer a single version and have let the JIT compiler sort out the rest? When I see these kinds offering is it just that the developer decided to create a native image using a tool like ngen in order to avoid a JIT? Someone please help me out here, I feel like I'm missing something of note. Updated From what I got below, both x86 and x64 builds are offered because one or more of the following reasons: The developer wanted to avoid JITing and created a native image of his code, targeting a given architecture using a tool like ngen.exe. The assembly contains platform specific COM calls and so it makes no point to build it as AnyCPU. In these cases builds that target different platforms may contain different code. The assembly may contain Win32 calls using pinvoke which won't get remapped by a JIT and so the build should target the platform it is bound to.

    Read the article

  • How to reference SMF libraries when deploying on phone 7 (Release)

    - by aHaH
    Initially, at Visual Studio, I clicked debug instead of release to deploy my app on phone 7 device. No errors, works perfectly fine! Received multitude of errors that mention that some of the libraries don't seem to exist on the mobile phone. For example, extract from the entire list of errors include Warning 10 The referenced component 'Microsoft.SilverlightMediaFramework.Utilities' could not be found. Warning 3 Could not resolve this reference. Could not locate the assembly "Microsoft.SilverlightMediaFramework.Plugins". Check to make sure the assembly exists on disk. If this reference is required by your code, you may get compilation errors. SLARToolKitWinPhoneSample In addition, im also using Slartookit to power up the AR capabilities. Deploying (Release) on the mobile prompts the following errors too. Error 11 The type or namespace name 'SLARToolKit' could not be found (are you missing a using directive or an assembly reference?) What should I do? Will updating the mobile solve this? Do I have to manually install? Or? Thanks

    Read the article

  • Move SELECT to SQL Server side

    - by noober
    Hello all, I have an SQLCLR trigger. It contains a large and messy SELECT inside, with parts like: (CASE WHEN EXISTS(SELECT * FROM INSERTED I WHERE I.ID = R.ID) THEN '1' ELSE '0' END) AS IsUpdated -- Is selected row just added? as well as JOINs etc. I like to have the result as a single table with all included. Question 1. Can I move this SELECT to SQL Server side? If yes, how to do this? Saying "move", I mean to create a stored procedure or something else that can be executed before reading dataset in while cycle. The 2 following questions make sense only if answer is "yes". Why do I want to move SELECT? First off, I don't like mixing SQL with C# code. At second, I suppose that server-side queries run faster, since the server have more chances to cache them. Question 2. Am I right? Is it some sort of optimizing? Also, the SELECT contains constant strings, but they are localizable. For instance, WHERE R.Status = "Enabled" "Enabled" should be changed for French, German etc. So, I want to write 2 static methods -- OnCreate and OnDestroy -- then mark them as stored procedures. When registering/unregistering my assembly on server side, just call them respectively. In OnCreate format the SELECT string, replacing {0}, {1}... with required values from the assembly resources. Then I can localize resources only, not every script. Question 3. Is it good idea? Is there an existing attribute to mark methods to be executed by SQL Server automatically after (un)registartion an assembly? Regards,

    Read the article

  • C#: at design time, how can I reliably determine the type of a variable that is declared using var?

    - by Cheeso
    I'm working on a completion (intellisense) facility for C# in emacs. The idea is, if a user types a fragment, then asks for completion via a particular keystroke combination, the completion facility will use .NET reflection to determine the possible completions. Doing this requires that the type of the thing being completed, be known. If it's a string, it has a set of known methods; if it's an Int32, it has a separate set of methods, and so on. Using semantic, a code lexer/parser package available in emacs, I can locate the variable declarations, and their types. Given that, it's straightforward to use reflection to get the methods and properties on the type, and then present the list of options to the user. The problem arrives when the code uses var in the declaration. How can I reliably determine the actual type used, when the variable is declared with the var keyword? Just to be clear, I don't need to determine it at runtime. I want to determine it at "Design time". So far the best idea I have is: extract the declaration statement, eg var foo = "a string value"; concatenate a statement foo.GetType(); dynamically compile the resulting C# fragment it into a new assembly load the assembly into a new AppDomain, run the framgment and get the return type. unload and discard the assembly This sounds awfully heavyweight, for each completion request in the editor. Any better ideas out there?

    Read the article

  • Why can a public class not inherit from a less visible one?

    - by Dan Tao
    I apologize if this question has been asked before. I've searched SO somewhat and wasn't able to find it. I'm just curious what the rationale behind this design was/is. Obviously I understand that private/internal members of a base type cannot, nor should they, be exposed through a derived public type. But it seems to my naive thinking that the "hidden" parts could easily remain hidden while some base functionality is still shared and a new interface is exposed publicly. I'm thinking of something along these lines: Assembly X internal class InternalClass { protected virtual void DoSomethingProtected() { // Let's say this method provides some useful functionality. // Its visibility is quite limited (only to derived types in // the same assembly), but at least it's there. } } public class PublicClass : InternalClass { public void DoSomethingPublic() { // Now let's say this method is useful enough that this type // should be public. What's keeping us from leveraging the // base functionality laid out in InternalClass's implementation, // without exposing anything that shouldn't be exposed? } } Assembly Y public class OtherPublicClass : PublicClass { // It seems (again, to my naive mind) that this could work. This class // simply wouldn't be able to "see" any of the methods of InternalClass // from AssemblyX directly. But it could still access the public and // protected members of PublicClass that weren't inherited from // InternalClass. Does this make sense? What am I missing? }

    Read the article

  • Touchpad mouse problem

    - by megatr0n
    Hi all. I have a toshiba satellite and its been behaving weirdly. It only works at the password prompt screen to logon but as soon as I am logged in, it just stops working. Left nor right button clicks are working. I am running vista home. Any pointers on how to go about this? Thanks.

    Read the article

  • OpenVPN, Great on Windows, VERY slow on Mac...

    - by Phsion
    Hello, I'm not really an IT Pro, but this seemed like the best place to ask this question... I have setup VPN networks in the past, for fun, and everything was great, but now I've set one up for my boss, and while my computers all work great, his Mac machines are almost too slow to work with. Its pretty much vanilla configs all around, anyone have any ideas? Its a TUN routing setup over UDP. Back Story: My boss travels a lot, and wants to be able to access all his files from the road, and is also pretty paranoid about security (even though knows almost nothing about computers). SO i figured a VPN would be the answer. I went with OpenVPN, but there are some other issues. The only ISP we can get in our area besides Dial-UP is a crappy Satellite provider, that doesn't offer public IPs unless your willing to pay, so while the computers and VPN setup are pretty vanilla, the routing and structure is strange to get around this limitation. Specs: Its OpenVPN2, and there are six machines using it (only three actually use it, the rest are my test machines), one Windows 7 laptop, two XP Desktops, one OS X 10.5 Desktop, one 10.6 Desktop, and one 10.6 Laptop. One XP Desktop sits at my house and acts as the server (6Mbs/2Mbs FIOS connection). One XP desktop sits at the office and hosts a webpage that will wake up the Main Mac Desktop from sleep, and also ping all the machines on the VPN and show their status. The main office mac (10.6) stays in sleep mode until it gets the Wake-On-Lan packet from the Office XP, and then it auto connects to the VPN and opens itself up. The reason for all this is the Satellite private IP crap means i cant directly access the office machines outside of the LAN, so everyone connects to my house first, then they talk to each other from there. The Wake On Lan weirdness is because my boss doesn't want to leave the main Mac on all the time, and making a quick and dirty webpage was the easiest way to send a Magic Packet from inside the LAN without confusing my boss. The VPN uses Client Config files to make static IPs for the client. The only thing i found in google was some changes to the VPN MTU settings (down to 1400) but no real help. Oh, and i forgot...all the windows machines just have OpenVPN start as a service. The Mac laptop uses tunnelblick (an OpenVPN GUI) and the Mac Desktops use OpenVPN in normal command line mode. Server Config: tun-mtu 1500 fragment 1450 mssfix 1450 management localhost #### port #### proto udp dev tun ca ####### cert ####### key ###### dh ###### server 10.8.0.0 255.255.255.0 ifconfig-pool-persist ipp.txt client-config-dir ccd route 10.8.0.0 255.255.255.252 client-to-client keepalive 10 120 comp-lzo persist-key persist-tun status openvpn-status log Client Configs (all are simple variations on this) tun-mtu 1500 fragment 1450 mssfix 1450 client dev tun proto udp remote ######## #### resolv-retry infinite nobind persist-key presist-tun ca ##### cert ##### key ##### ns-cert-type server comp-lzo verb 3

    Read the article

  • Forward all traffic through an ssh tunnel

    - by Eamorr
    I hope someone can follow this and I'll explain as best I can. I'm trying to forward all traffic from port 6999 on x.x.x.224, through an ssh tunnel, and onto port 7000 on x.x.x.218. Here is some ASCII art: |browser|-----|Squid on x.x.x.224|------|ssh tunnel|------<satellite link>-----|Squid on x.x.x.218|-----|www| 3128 6999 7000 80 When I remove the ssh tunnel, everything works fine. The idea is to turn off encryption on the ssh tunnel (to save bandwidth) and turn on maximum compression (to save more bandwidth). This is because it's a satellite link. Here's the ssh tunnel I've been using: ssh -C -f -C -o CompressionLevel=9 -o Cipher=none [email protected] -L 7000:172.16.1.224:6999 -N The trouble is, I don't know how to get data from Squid on x.x.x.224 into the ssh tunnel? Am I going about this the wrong way? Should I create an ssh tunnel on x.x.x.218? I use iptables to stop squid on x.x.x.224 from reading port 80, but to feed from port 6999 instead (i.e. via the ssh tunnel). Do I need another iptables rule? Any comments greatly appreciated. Many thanks in advance, Regarding Eduardo Ivanec's question, here is a netstat -i any port 7000 -nn dump from x.x.x.218: 14:42:15.386462 IP 172.16.1.224.40006 > 172.16.1.218.7000: Flags [S], seq 2804513708, win 14600, options [mss 1460,sackOK,TS val 86702647 ecr 0,nop,wscale 4], length 0 14:42:15.386690 IP 172.16.1.218.7000 > 172.16.1.224.40006: Flags [R.], seq 0, ack 2804513709, win 0, length 0 Update 2: When I run the second command, I get the following error in my browser: ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://109.123.109.205/index.php Zero Sized Reply Squid did not receive any data for this request. Your cache administrator is webmaster. Generated Fri, 01 Jul 2011 16:06:06 GMT by remote-site (squid/2.7.STABLE9) remote-site is 172.16.1.224 When I do a tcpdump -i any port 7000 -nn I get the following: root@remote-site:~# tcpdump -i any port 7000 -nn tcpdump: verbose output suppressed, use -v or -vv for full protocol decode listening on any, link-type LINUX_SLL (Linux cooked), capture size 65535 bytes channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused channel 2: open failed: connect failed: Connection refused

    Read the article

  • Will Windows 7 work at all on my old toshiba [closed]

    - by andrew
    Windows 7 requires the following specifications: 1 gigahertz (GHz) or faster 32-bit (x86) or 64-bit (x64) processor 1 gigabyte (GB) RAM (32-bit) or 2 GB RAM (64-bit) 16 GB available hard disk space (32-bit) or 20 GB (64-bit) DirectX 9 graphics device with WDDM 1.0 or higher driver Will it work at all on my old toshiba Satellite A100 PSAA8C-SK400E Intel® Core™ Solo processor T1350 (1.86GHz, 533MHz FSB, L1 Cache 32KB/32KB, L2 Cache 2MB) Standard Memory: 2x512 MB DDR2 Intel® Graphics Media Accelerator 950 with 8MB-128MB. The main problem I can see is that the graphics is not up to it.

    Read the article

  • Windows XP blue screen 0x8E error troubleshooting

    - by dotnet-practitioner
    I get following blue screen after running my laptop for an hour... A problem has been detected and windows has been shut down to prevent damage to your computer. [...] Technical Information: *** STOP 0x0000008E (0xc0000005, 0x805B03F5, 0xF703DC7C, 0x00000000) [...] So how can I tell if this is faulty memory or some other hardware problem? My laptop is a Toshiba Satellite A45-S250.

    Read the article

  • Can a faulty battery cause a laptop to crash?

    - by Paul Johnson
    After replacing a blown out motherboard, my Toshiba Satellite C600 is still malfunctioning lately: BSODs. Distorted graphics, and freezes. Sudden shutdowns. After removing the battery and doing a re-format the laptop works perfectly (I should mention the problems continued before removing the battery after the re-format). I haven't seen a fault while solely running on A/C power for two days. Could the problem be a faulty battery?

    Read the article

  • Laptop automatic shutdown after 2 seconds

    - by leladax
    I'm trying to insvestigate which component produces this behavior. Other indications show it may be the GPU but I wonder if anyone knows more. It's a Toshiba Satellite X200 description: AC power shows the power being fed normally, when turned on the fan works and it appears to be starting up but after 2 seconds it shuts down with only the 'AC power connected" led on. -- seconds are about up to 4,maybe not 2 exactly.

    Read the article

  • Program to set time on local computer using GPS data

    - by dmkerr
    I have a laptop running Windows XP that does not connect to the Internet and I would like to use a USB GPS receiver as a time source to set the clock. Generally, the laptop will not have access to the open sky so getting a strong, multi-satellite connection is not likely. Ideally, I would like to be able to have the program detect the GPS receiver and set the clock without intervention from the user. Is what I'm seeking even feasible?

    Read the article

  • "Unable to read data from the transport connection: net_io_connectionclosed." - Windows Vista Busine

    - by John DaCosta
    Unable to test sending email from .NET code in Windows Vista Business. I am writing code which I will migrate to an SSIS Package once it its proven. The code is to send an error message via email to a list of recipients. The code is below, however I am getting an exception when I execute the code. I created a simple class to do the mailing... the design could be better, I am testing functionality before implementing more robust functionality, methods, etc. namespace LabDemos { class Program { static void Main(string[] args) { Mailer m = new Mailer(); m.test(); } } } namespace LabDemos { class MyMailer { List<string> _to = new List<string>(); List<string> _cc = new List<string>(); List<string> _bcc = new List<string>(); String _msgFrom = ""; String _msgSubject = ""; String _msgBody = ""; public void test(){ //create the mail message MailMessage mail = new MailMessage(); //set the addresses mail.From = new MailAddress("[email protected]"); //set the content mail.Subject = "This is an email"; mail.Body = "this is a sample body"; mail.IsBodyHtml = false; //send the message SmtpClient smtp = new SmtpClient(); smtp.Host = "emailservername"; smtp.Port = 25; smtp.UseDefaultCredentials = true; smtp.Send(mail); } } Exception Message Inner Exception {"Unable to read data from the transport connection: net_io_connectionclosed."} Stack Trace " at System.Net.Mail.SmtpReplyReaderFactory.ProcessRead(Byte[] buffer, Int32 offset, Int32 read, Boolean readLine)\r\n at System.Net.Mail.SmtpReplyReaderFactory.ReadLines(SmtpReplyReader caller, Boolean oneLine)\r\n at System.Net.Mail.SmtpReplyReaderFactory.ReadLine(SmtpReplyReader caller)\r\n at System.Net.Mail.SmtpConnection.GetConnection(String host, Int32 port)\r\n at System.Net.Mail.SmtpTransport.GetConnection(String host, Int32 port)\r\n at System.Net.Mail.SmtpClient.GetConnection()\r\n at System.Net.Mail.SmtpClient.Send(MailMessage message)" Outer Exception System.Net.Mail.SmtpException was unhandled Message="Failure sending mail." Source="System" StackTrace: at System.Net.Mail.SmtpClient.Send(MailMessage message) at LabDemos.Mailer.test() in C:\Users\username\Documents\Visual Studio 2008\Projects\LabDemos\LabDemos\Mailer.cs:line 40 at LabDemos.Program.Main(String[] args) in C:\Users\username\Documents\Visual Studio 2008\Projects\LabDemos\LabDemos\Program.cs:line 48 at System.AppDomain._nExecuteAssembly(Assembly assembly, String[] args) at System.AppDomain.nExecuteAssembly(Assembly assembly, String[] args) at System.Runtime.Hosting.ManifestRunner.Run(Boolean checkAptModel) at System.Runtime.Hosting.ManifestRunner.ExecuteAsAssembly() at System.Runtime.Hosting.ApplicationActivator.CreateInstance(ActivationContext activationContext, String[] activationCustomData) at System.Runtime.Hosting.ApplicationActivator.CreateInstance(ActivationContext activationContext) at System.Activator.CreateInstance(ActivationContext activationContext) at Microsoft.VisualStudio.HostingProcess.HostProc.RunUsersAssemblyDebugInZone() at System.Threading.ThreadHelper.ThreadStart_Context(Object state) at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state) at System.Threading.ThreadHelper.ThreadStart() InnerException: System.IO.IOException Message="Unable to read data from the transport connection: net_io_connectionclosed." Source="System" StackTrace: at System.Net.Mail.SmtpReplyReaderFactory.ProcessRead(Byte[] buffer, Int32 offset, Int32 read, Boolean readLine) at System.Net.Mail.SmtpReplyReaderFactory.ReadLines(SmtpReplyReader caller, Boolean oneLine) at System.Net.Mail.SmtpReplyReaderFactory.ReadLine(SmtpReplyReader caller) at System.Net.Mail.SmtpConnection.GetConnection(String host, Int32 port) at System.Net.Mail.SmtpTransport.GetConnection(String host, Int32 port) at System.Net.Mail.SmtpClient.GetConnection() at System.Net.Mail.SmtpClient.Send(MailMessage message) InnerException:

    Read the article

  • Server 2012 AD-DS Setup Fails (Microsoft.Directory.Services.Deployment.DeepTasks.DeepTasks not found)

    - by Daniel Steiner
    Good Morning everyone, I am currently trying to promote my 2012 Server to a Domain Controller but when I am at the first step in the setup I get the Error Message (German, Original Message): [Bereitstellungskonfiguration] Fehler bei der Bestimmung, ob der Zielserver bereits ein Domänencontroller ist: Der Typ [Microsoft.Directory.Services.Deployment.DeepTasks.DeepTasks] wurde nicht gefunden: Vergewissern Sie sich, dass die Assembly, die diesen Typ enthält, geladen ist. (Translated to English): Error while determining, if the Targetserver already is a Domain Controller: The Type [Microsoft.Directory.Services.Deployment.DeepTasks.DeepTasks] was not found: Make sure, that the assembly, that contains this type, is loaded. Thus I can neither Configure the AD-DS nor deinstall them via Server Manager. Any Help how to fix that problem would be greatly appricieated.

    Read the article

  • Visual Studio 2010 and javascript debugging in external javascript files (embedded and minified).

    - by OKB
    Hi, The asp.net web application I'm working on is written in asp.net 3.5, the web app solution is upgraded from VS 2008 (don't know if that matter). The solution had javascript in the aspx files before I moved the javascript to external files. Now what I have done is to set all the javascript files to be embedded resource (except the jquery.js file) and I want to minify them when building for release by using the MS Ajax Minifier. I want to use the minified javascript files when I'm in the RELEASE mode and when I'm in DEBUG mode I want to use the "normal" versions. My problem now is that I'm unable to debug the javascript code in debug mode. When I set a break point a javascript function, VS is not breaking at all when the function is executed. I have added this entry in my web.config: <system.web> <compilation defaultLanguage="c#" debug="true" /> </system.web> Here how I register the jquery in an aspx-file: <asp:ScriptManagerProxy ID="ScriptManagerProxy1" runat="server"> <Scripts> <asp:ScriptReference Path="~/Javascript/jquery.js"/> </Scripts> </asp:ScriptManagerProxy> External javascript registration in the code-behind: #if DEBUG [assembly: WebResource("braArkivWeb.Javascript.jquery.js", "text/javascript")] [assembly: WebResource(braArkivWeb.ArkivdelSearch.JavaScriptResource, "text/javascript")] #else [assembly: WebResource("braArkivWeb.Javascript.jquery.min.js", "text/javascript")] [assembly: WebResource(braArkivWeb.ArkivdelSearch.JavaScriptMinResource, "text/javascript")] #endif public partial class ArkivdelSearch : Page { public const string JavaScriptResource = "braArkivWeb.ArkivdelSearch.js"; public const string JavaScriptMinResource = "braArkivWeb.ArkivdelSearch.min.js"; protected void Page_Init(object sender, EventArgs e) { InitPageClientScript(); } private void InitPageClientScript() { #if DEBUG this.Page.ClientScript.RegisterClientScriptResource(typeof(ArkivdelSearch), "braArkivWeb.Javascript.jquery.js"); this.Page.ClientScript.RegisterClientScriptResource(typeof(ArkivdelSearch), JavaScriptResource); #else this.Page.ClientScript.RegisterClientScriptResource(typeof(ArkivdelSearch), "braArkivWeb.Javascript.jquery.min.js"); this.Page.ClientScript.RegisterClientScriptResource(typeof(ArkivdelSearch), JavaScriptMinResource); #endif StringBuilder sb = new StringBuilder(); Page.ClientScript.RegisterStartupScript(typeof(ArkivdelSearch), "initArkivdelSearch", sb.ToString(), true); } } In the project file I have added this code to minify the javascripts: <!-- Minify all JavaScript files that were embedded as resources --> <UsingTask TaskName="AjaxMin" AssemblyFile="$(MSBuildProjectDirectory)\..\..\SharedLib\AjaxMinTask.dll" /> <PropertyGroup> <ResGenDependsOn> MinifyJavaScript; $(ResGenDependsOn) </ResGenDependsOn> </PropertyGroup> <Target Name="MinifyJavaScript" Condition=" '$(ConfigurationName)'=='Release' "> <Copy SourceFiles="@(EmbeddedResource)" DestinationFolder="$(IntermediateOutputPath)" Condition="'%(Extension)'=='.js'"> <Output TaskParameter="DestinationFiles" ItemName="EmbeddedJavaScriptResource" /> </Copy> <AjaxMin JsSourceFiles="@(EmbeddedJavaScriptResource)" JsSourceExtensionPattern="\.js$" JsTargetExtension=".js" /> <ItemGroup> <EmbeddedResource Remove="@(EmbeddedResource)" Condition="'%(Extension)'=='.js'" /> <EmbeddedResource Include="@(EmbeddedJavaScriptResource)" /> <FileWrites Include="@(EmbeddedJavaScriptResource)" /> </ItemGroup> </Target> Do you see what I'm doing wrong? Or what I'm missing in order to be able to debug my javascript code? Best Regards, OKB

    Read the article

  • Call Webservice without adding a WebReference - with Complex Types

    - by ck
    I'm using the code at This Site to call a webservice dynamically. [SecurityPermissionAttribute(SecurityAction.Demand, Unrestricted = true)] public static object CallWebService(string webServiceAsmxUrl, string serviceName, string methodName, object[] args) { System.Net.WebClient client = new System.Net.WebClient(); //-Connect To the web service using (System.IO.Stream stream = client.OpenRead(webServiceAsmxUrl + "?wsdl")) { //--Now read the WSDL file describing a service. ServiceDescription description = ServiceDescription.Read(stream); ///// LOAD THE DOM ///////// //--Initialize a service description importer. ServiceDescriptionImporter importer = new ServiceDescriptionImporter(); importer.ProtocolName = "Soap12"; // Use SOAP 1.2. importer.AddServiceDescription(description, null, null); //--Generate a proxy client. importer.Style = ServiceDescriptionImportStyle.Client; //--Generate properties to represent primitive values. importer.CodeGenerationOptions = System.Xml.Serialization.CodeGenerationOptions.GenerateProperties; //--Initialize a Code-DOM tree into which we will import the service. CodeNamespace nmspace = new CodeNamespace(); CodeCompileUnit unit1 = new CodeCompileUnit(); unit1.Namespaces.Add(nmspace); //--Import the service into the Code-DOM tree. This creates proxy code //--that uses the service. ServiceDescriptionImportWarnings warning = importer.Import(nmspace, unit1); if (warning == 0) //--If zero then we are good to go { //--Generate the proxy code CodeDomProvider provider1 = CodeDomProvider.CreateProvider("CSharp"); //--Compile the assembly proxy with the appropriate references string[] assemblyReferences = new string[5] { "System.dll", "System.Web.Services.dll", "System.Web.dll", "System.Xml.dll", "System.Data.dll" }; CompilerParameters parms = new CompilerParameters(assemblyReferences); CompilerResults results = provider1.CompileAssemblyFromDom(parms, unit1); //-Check For Errors if (results.Errors.Count > 0) { StringBuilder sb = new StringBuilder(); foreach (CompilerError oops in results.Errors) { sb.AppendLine("========Compiler error============"); sb.AppendLine(oops.ErrorText); } throw new System.ApplicationException("Compile Error Occured calling webservice. " + sb.ToString()); } //--Finally, Invoke the web service method Type foundType = null; Type[] types = results.CompiledAssembly.GetTypes(); foreach (Type type in types) { if (type.BaseType == typeof(System.Web.Services.Protocols.SoapHttpClientProtocol)) { Console.WriteLine(type.ToString()); foundType = type; } } object wsvcClass = results.CompiledAssembly.CreateInstance(foundType.ToString()); MethodInfo mi = wsvcClass.GetType().GetMethod(methodName); return mi.Invoke(wsvcClass, args); } else { return null; } } } This works fine when I use built in types, but for my own classes, I get this: Event Type: Error Event Source: TDX Queue Service Event Category: None Event ID: 0 Date: 12/04/2010 Time: 12:12:38 User: N/A Computer: TDXRMISDEV01 Description: System.ArgumentException: Object of type 'TDXDataTypes.AgencyOutput' cannot be converted to type 'AgencyOutput'. Server stack trace: at System.RuntimeType.CheckValue(Object value, Binder binder, CultureInfo culture, BindingFlags invokeAttr) at System.Reflection.MethodBase.CheckArguments(Object[] parameters, Binder binder, BindingFlags invokeAttr, CultureInfo culture, Signature sig) at System.Reflection.RuntimeMethodInfo.Invoke(Object obj, BindingFlags invokeAttr, Binder binder, Object[] parameters, CultureInfo culture, Boolean skipVisibilityChecks) at System.Reflection.RuntimeMethodInfo.Invoke(Object obj, BindingFlags invokeAttr, Binder binder, Object[] parameters, CultureInfo culture) at System.Reflection.MethodBase.Invoke(Object obj, Object[] parameters) at TDXQueueEngine.GenericWebserviceProxy.CallWebService(String webServiceAsmxUrl, String serviceName, String methodName, Object[] args) in C:\CkAdmDev\TDXQueueEngine\TDXQueueEngine\TDXQueueEngine\GenericWebserviceProxy.cs:line 76 at TDXQueueEngine.TDXQueueWebserviceItem.Run() in C:\CkAdmDev\TDXQueueEngine\TDXQueueEngine\TDXQueueEngine\TDXQueueWebserviceItem.cs:line 99 at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Int32 methodPtr, Boolean fExecuteInContext, Object[]& outArgs) at System.Runtime.Remoting.Messaging.StackBuilderSink.PrivateProcessMessage(RuntimeMethodHandle md, Object[] args, Object server, Int32 methodPtr, Boolean fExecuteInContext, Object[]& outArgs) at System.Runtime.Remoting.Messaging.StackBuilderSink.AsyncProcessMessage(IMessage msg, IMessageSink replySink) Exception rethrown at [0]: at System.Runtime.Remoting.Proxies.RealProxy.EndInvokeHelper(Message reqMsg, Boolean bProxyCase) at System.Runtime.Remoting.Proxies.RemotingProxy.Invoke(Object NotUsed, MessageData& msgData) at TDXQueueEngine.TDXQueue.RunProcess.EndInvoke(IAsyncResult result) at TDXQueueEngine.TDXQueue.processComplete(IAsyncResult ar) in C:\CkAdmDev\TDXQueueEngine\TDXQueueEngine\TDXQueueEngine\TDXQueue.cs:line 130 For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. The classes reference the same assembly and the same version. Do I need to include my assembly as a reference when building the temporary assembly? If so, how? Thanks.

    Read the article

  • Problem using psexec to remotely GAC a file

    - by Andrew Dunaway
    As part of a deployment process I am trying to GAC a series of files. The actual build process occurs on a build server, and I am trying to use psexec to GAC the files on whichever machine has requested the build. The current line I am trying to execute is: C:\PsToolspsexec.exe \COMPUTER -u USER -p PASS gacutil.exe -i Assembly.dll -f The error that I am getting back is: Failure adding assembly to the cache: The system cannot find the file specified. So apparently the dll reference is on the remote box, and unfortunately the dll is sitting on the build box. Is there any way to just do this with psexec somehow, or do I need to copy it to some temporary location on the \\COMPUTER? I know there are commands to copy the executable as part of the psexec process, but I can't seem to find anything similar for supporting files.

    Read the article

  • Object of type 'customObject' cannot be converted to type 'customObject'.

    - by Phani Kumar PV
    i am receiving the follwing error when i am invoking a custom object "Object of type 'customObject' cannot be converted to type 'customObject'." Following is the scenario when i am getting the error i am invoking a method in a dll dynamically. Load an assembly CreateInstance.... calling MethodInfo.Invoke() passing int, string as a parameter for my method is working fine = No exceptions are thrown. But if I try and pass a one of my own custom class objects as a parameter, then I get an ArgumentException exception, and it is not either an ArgumentOutOfRangeException or ArgumentNullException. "Object of type 'customObject' cannot be converted to type 'customObject'." I am doing this in a web application. The class file containing the method is in a different proj . also the custom object is a sepearte class in the same file. there is no such thing called a static aseembly in my code. I am trying to invoke a webmethod dynamically. this webmethod is having the customObject type as an input parameter. So when i invoke the webmethod i am dynamically creating the proxy assembly and all. From the same assembly i am trying to create an instance of the cusotm object assinging the values to its properties and then passing this object as a parameter and invoking the method. everything is dynamic and nothing is created static.. :( add reference is not used. Following is a sample code i tried to create it public static object CallWebService(string webServiceAsmxUrl, string serviceName, string methodName, object[] args) { System.Net.WebClient client = new System.Net.WebClient(); //-Connect To the web service using (System.IO.Stream stream = client.OpenRead(webServiceAsmxUrl + "?wsdl")) { //--Now read the WSDL file describing a service. ServiceDescription description = ServiceDescription.Read(stream); ///// LOAD THE DOM ///////// //--Initialize a service description importer. ServiceDescriptionImporter importer = new ServiceDescriptionImporter(); importer.ProtocolName = "Soap12"; // Use SOAP 1.2. importer.AddServiceDescription(description, null, null); //--Generate a proxy client. importer.Style = ServiceDescriptionImportStyle.Client; //--Generate properties to represent primitive values. importer.CodeGenerationOptions = System.Xml.Serialization.CodeGenerationOptions.GenerateProperties; //--Initialize a Code-DOM tree into which we will import the service. CodeNamespace nmspace = new CodeNamespace(); CodeCompileUnit unit1 = new CodeCompileUnit(); unit1.Namespaces.Add(nmspace); //--Import the service into the Code-DOM tree. This creates proxy code //--that uses the service. ServiceDescriptionImportWarnings warning = importer.Import(nmspace, unit1); if (warning == 0) //--If zero then we are good to go { //--Generate the proxy code CodeDomProvider provider1 = CodeDomProvider.CreateProvider("CSharp"); //--Compile the assembly proxy with the appropriate references string[] assemblyReferences = new string[5] { "System.dll", "System.Web.Services.dll", "System.Web.dll", "System.Xml.dll", "System.Data.dll" }; CompilerParameters parms = new CompilerParameters(assemblyReferences); CompilerResults results = provider1.CompileAssemblyFromDom(parms, unit1); //-Check For Errors if (results.Errors.Count > 0) { StringBuilder sb = new StringBuilder(); foreach (CompilerError oops in results.Errors) { sb.AppendLine("========Compiler error============"); sb.AppendLine(oops.ErrorText); } throw new System.ApplicationException("Compile Error Occured calling webservice. " + sb.ToString()); } //--Finally, Invoke the web service method Type foundType = null; Type[] types = results.CompiledAssembly.GetTypes(); foreach (Type type in types) { if (type.BaseType == typeof(System.Web.Services.Protocols.SoapHttpClientProtocol)) { Console.WriteLine(type.ToString()); foundType = type; } } object wsvcClass = results.CompiledAssembly.CreateInstance(foundType.ToString()); MethodInfo mi = wsvcClass.GetType().GetMethod(methodName); return mi.Invoke(wsvcClass, args); } else { return null; } } } I cant find anything static being done by me. any help is greatly appreciated. Regards, Phani Kumar PV

    Read the article

< Previous Page | 65 66 67 68 69 70 71 72 73 74 75 76  | Next Page >