Search Results

Search found 1250 results on 50 pages for 'san'.

Page 7/50 | < Previous Page | 3 4 5 6 7 8 9 10 11 12 13 14  | Next Page >

  • HP/Lenovo alternative to Buffalo iSCSI TerraStation?

    - by Robin Day
    I'm looking at virtualising some of our infrastructure in order to allow for more resiliance and future expandability. We have successfully virtualised on single servers with Direct Attached Storage and are now looking for a more future proof solution using a high powered host (or two) and a SAN (or two). I'm thinking that the host machine will probably be an HP ProLiant DL360 G7 (all of our exisiting infrastructure is HP). Unfortunately, I am new to the world of SANs. From what I can see, the Buffalo Terrastation III is all I would need in order to setup an iSCSI SAN for VMWare to use. However, I'm a little reticent to go that way as it's a bit too "entry level" for my liking. In particular I would be very keen for more redundancy, power, networking, etc. I'm also very aware that you "get what you pay for". Therefore, can anyone reccommend equivalents from the big boys? HP/Lenovo? I have searched high and low on the HP site and seen many options but am struggling to work out if it is all the hardware I will need. Some options appear to need separate controllers from disk enclosures, etc.

    Read the article

  • HP/IBM alternative to Buffalo iSCSI TerraStation?

    - by Robin Day
    I'm looking at virtualising some of our infrastructure in order to allow for more resiliance and future expandability. We have successfully virtualised on single servers with Direct Attached Storage and are now looking for a more future proof solution using a high powered host (or two) and a SAN (or two). I'm thinking that the host machine will probably be an HP ProLiant DL360 G7 (all of our exisiting infrastructure is HP). Unfortunately, I am new to the world of SANs. From what I can see, the Buffalo Terrastation III is all I would need in order to setup an iSCSI SAN for VMWare to use. However, I'm a little reticent to go that way as it's a bit too "entry level" for my liking. In particular I would be very keen for more redundancy, power, networking, etc. I'm also very aware that you "get what you pay for". Therefore, can anyone reccommend equivalents from the big boys? HP/IBM? I have searched high and low on the HP site and seen many options but am struggling to work out if it is all the hardware I will need. Some options appear to need separate controllers from disk enclosures, etc.

    Read the article

  • SQL Server 2005 standard filegroups / files for performance on SAN

    - by Blootac
    Ok so I've just been on a SQL Server course and we discussed the usage scenarios of multiple filegroups and files when in use over local RAID and local disks but we didn't touch SAN scenarios so my question is as follows; I currently have a 250 gig database running on SQL Server 2005 where some tables have a huge number of writes and others are fairly static. The database and all objects reside in a single file group with a single data file. The log file is also on the same volume. My interpretation is that separate data files should be used across different disks to lessen disk contention and that file groups should be used for partitioning of data. However, with a SAN you obviously don't really have the same issue of disk contention that you do with a small RAID setup (or at least we don't at the moment), and standard edition doesn't support partitioning. So in order to improve parallelism what should I do? My understanding of various Microsoft publications is that if I increase the number of data files, separate threads can act across each file separately. Which leads me to the question how many files should I have. One per core? Should I be putting tables and indexes with high levels of activity in separate file groups, each with the same number of data files as we have cores? Thank you

    Read the article

  • EMC ESRS stops working when it is VMotioned

    - by makerofthings7
    EMC is on site and told me: The ESRS SAN monitoring solution will cease to function if that host is VMotioned In case anyone doesn't know, the ESRS is a dial home solution that works over IP. An EMC SecureID is required to add or modify the list of devices that are monitored. The ESRS software is installed on the customer premises. Question If ESRS truly fails to work, as the EMC engineer stated, and based on our customer experience, what is it within VMWare that is exposed to the virtualized host that allows this behavior to happen?

    Read the article

  • SQL Server iSCSI session issue with a NetApp SAN

    - by Matt Beckman
    We had an issue early this morning when iSCSI issues broke connectivity with a few of our databases (resulting in a SQL Server Error 21). Attempts to DBCC CheckDB did not work, and the only solution was to restart the SQL Service. Is there a known reason why an iSCSI initiator session would reset itself out of the blue? Example below from the NetApp syslog. This set of errors was replicated 4 times (once for each SQL server in production). Only one SQL server was noticeably impacted, however. [san1: iscsi.notice:notice]: ISCSI: iswta, ISID Rule: new connection from same initiator, shutting down old session 7 [san1: iscsi.notice:notice]: ISCSI: iswta, New session from initiator iqn.1991-05.com.microsoft:sql1.example.corp at IP addr 10.xxx.xxx.123

    Read the article

  • Problems connecting Clariion LUNS to Solaris 10

    - by vialde
    I've got a Clariion San and a Solaris 10 server with an emulex HBA. The Thin LUNS are visible in Solaris and I can happily format the raw devices. Unfortunately that's all I can do. All other operations result in I/O errors. I'm running current versions of PowerPath and Solaris is patched as high as it'll go. Anyone have any similar experiences?

    Read the article

  • HP StorageWorks P4500 G2 Manager Management

    - by MDMarra
    According to the documentation, a management group should have an odd number of managers greater than 1. I have a four node SAN consisting of P4500 G2s. I plan on having two clusters with two nodes each in this management group, i.e.: -Managent_Group1 -Cluster1 -Node1 -Node2 -Cluster2 -Node3 -Node4 Are there any issues running standard managers on Node1, Node2, and Node3? After reading the documentation, I'm still unclear about whether or not cluster membership matters in quorum consistency, or if they don't matter at all.

    Read the article

  • SQL IO and SAN troubles

    - by James
    We are running two servers with identical software setup but different hardware. The first one is a VM on VMWare on a normal tower server with dual core xeons, 16 GB RAM and a 7200 RPM drive. The second one is a VM on XenServer on a powerful brand new rack server, with 4 core xeons and shared storage. We are running Dynamics AX 2012 and SQL Server 2008 R2. When I insert 15 000 records into a table on the slow tower server (as a test), it does so in 13 seconds. On the fast server it takes 33 seconds. I re-ran these tests several times with the same results. I have a feeling it is some sort of IO bottleneck, so I ran SQLIO on both. Here are the results for the slow tower server: C:\Program Files (x86)\SQLIO>test.bat C:\Program Files (x86)\SQLIO>sqlio -kW -t8 -s120 -o8 -frandom -b8 -BH -LS C:\Tes tFile.dat sqlio v1.5.SG using system counter for latency timings, 14318180 counts per second 8 threads writing for 120 secs to file C:\TestFile.dat using 8KB random IOs enabling multiple I/Os per thread with 8 outstanding buffering set to use hardware disk cache (but not file cache) using current size: 5120 MB for file: C:\TestFile.dat initialization done CUMULATIVE DATA: throughput metrics: IOs/sec: 226.97 MBs/sec: 1.77 latency metrics: Min_Latency(ms): 0 Avg_Latency(ms): 281 Max_Latency(ms): 467 histogram: ms: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24+ %: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 99 C:\Program Files (x86)\SQLIO>sqlio -kR -t8 -s120 -o8 -frandom -b8 -BH -LS C:\Tes tFile.dat sqlio v1.5.SG using system counter for latency timings, 14318180 counts per second 8 threads reading for 120 secs from file C:\TestFile.dat using 8KB random IOs enabling multiple I/Os per thread with 8 outstanding buffering set to use hardware disk cache (but not file cache) using current size: 5120 MB for file: C:\TestFile.dat initialization done CUMULATIVE DATA: throughput metrics: IOs/sec: 91.34 MBs/sec: 0.71 latency metrics: Min_Latency(ms): 14 Avg_Latency(ms): 699 Max_Latency(ms): 1124 histogram: ms: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24+ %: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 100 C:\Program Files (x86)\SQLIO>sqlio -kW -t8 -s120 -o8 -fsequential -b64 -BH -LS C :\TestFile.dat sqlio v1.5.SG using system counter for latency timings, 14318180 counts per second 8 threads writing for 120 secs to file C:\TestFile.dat using 64KB sequential IOs enabling multiple I/Os per thread with 8 outstanding buffering set to use hardware disk cache (but not file cache) using current size: 5120 MB for file: C:\TestFile.dat initialization done CUMULATIVE DATA: throughput metrics: IOs/sec: 1094.50 MBs/sec: 68.40 latency metrics: Min_Latency(ms): 0 Avg_Latency(ms): 58 Max_Latency(ms): 467 histogram: ms: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24+ %: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 100 C:\Program Files (x86)\SQLIO>sqlio -kR -t8 -s120 -o8 -fsequential -b64 -BH -LS C :\TestFile.dat sqlio v1.5.SG using system counter for latency timings, 14318180 counts per second 8 threads reading for 120 secs from file C:\TestFile.dat using 64KB sequential IOs enabling multiple I/Os per thread with 8 outstanding buffering set to use hardware disk cache (but not file cache) using current size: 5120 MB for file: C:\TestFile.dat initialization done CUMULATIVE DATA: throughput metrics: IOs/sec: 1155.31 MBs/sec: 72.20 latency metrics: Min_Latency(ms): 17 Avg_Latency(ms): 55 Max_Latency(ms): 205 histogram: ms: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24+ %: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 100 Here are the results of the fast rack server: C:\Program Files (x86)\SQLIO>test.bat C:\Program Files (x86)\SQLIO>sqlio -kW -t8 -s120 -o8 -frandom -b8 -BH -LS E:\Tes tFile.dat sqlio v1.5.SG using system counter for latency timings, 62500000 counts per second 8 threads writing for 120 secs to file E:\TestFile.dat using 8KB random IOs enabling multiple I/Os per thread with 8 outstanding buffering set to use hardware disk cache (but not file cache) open_file: CreateFile (E:\TestFile.dat for write): The system cannot find the pa th specified. exiting C:\Program Files (x86)\SQLIO>sqlio -kR -t8 -s120 -o8 -frandom -b8 -BH -LS E:\Tes tFile.dat sqlio v1.5.SG using system counter for latency timings, 62500000 counts per second 8 threads reading for 120 secs from file E:\TestFile.dat using 8KB random IOs enabling multiple I/Os per thread with 8 outstanding buffering set to use hardware disk cache (but not file cache) open_file: CreateFile (E:\TestFile.dat for read): The system cannot find the pat h specified. exiting C:\Program Files (x86)\SQLIO>sqlio -kW -t8 -s120 -o8 -fsequential -b64 -BH -LS E :\TestFile.dat sqlio v1.5.SG using system counter for latency timings, 62500000 counts per second 8 threads writing for 120 secs to file E:\TestFile.dat using 64KB sequential IOs enabling multiple I/Os per thread with 8 outstanding buffering set to use hardware disk cache (but not file cache) open_file: CreateFile (E:\TestFile.dat for write): The system cannot find the pa th specified. exiting C:\Program Files (x86)\SQLIO>sqlio -kR -t8 -s120 -o8 -fsequential -b64 -BH -LS E :\TestFile.dat sqlio v1.5.SG using system counter for latency timings, 62500000 counts per second 8 threads reading for 120 secs from file E:\TestFile.dat using 64KB sequential IOs enabling multiple I/Os per thread with 8 outstanding buffering set to use hardware disk cache (but not file cache) open_file: CreateFile (E:\TestFile.dat for read): The system cannot find the pat h specified. exiting C:\Program Files (x86)\SQLIO>test.bat C:\Program Files (x86)\SQLIO>sqlio -kW -t8 -s120 -o8 -frandom -b8 -BH -LS c:\Tes tFile.dat sqlio v1.5.SG using system counter for latency timings, 62500000 counts per second 8 threads writing for 120 secs to file c:\TestFile.dat using 8KB random IOs enabling multiple I/Os per thread with 8 outstanding buffering set to use hardware disk cache (but not file cache) using current size: 5120 MB for file: c:\TestFile.dat initialization done CUMULATIVE DATA: throughput metrics: IOs/sec: 2575.77 MBs/sec: 20.12 latency metrics: Min_Latency(ms): 1 Avg_Latency(ms): 24 Max_Latency(ms): 655 histogram: ms: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24+ %: 0 0 0 5 8 9 9 9 8 5 3 1 1 1 1 0 0 0 0 0 0 0 0 0 37 C:\Program Files (x86)\SQLIO>sqlio -kR -t8 -s120 -o8 -frandom -b8 -BH -LS c:\Tes tFile.dat sqlio v1.5.SG using system counter for latency timings, 62500000 counts per second 8 threads reading for 120 secs from file c:\TestFile.dat using 8KB random IOs enabling multiple I/Os per thread with 8 outstanding buffering set to use hardware disk cache (but not file cache) using current size: 5120 MB for file: c:\TestFile.dat initialization done CUMULATIVE DATA: throughput metrics: IOs/sec: 1141.39 MBs/sec: 8.91 latency metrics: Min_Latency(ms): 1 Avg_Latency(ms): 55 Max_Latency(ms): 652 histogram: ms: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24+ %: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 91 C:\Program Files (x86)\SQLIO>sqlio -kW -t8 -s120 -o8 -fsequential -b64 -BH -LS c :\TestFile.dat sqlio v1.5.SG using system counter for latency timings, 62500000 counts per second 8 threads writing for 120 secs to file c:\TestFile.dat using 64KB sequential IOs enabling multiple I/Os per thread with 8 outstanding buffering set to use hardware disk cache (but not file cache) using current size: 5120 MB for file: c:\TestFile.dat initialization done CUMULATIVE DATA: throughput metrics: IOs/sec: 341.37 MBs/sec: 21.33 latency metrics: Min_Latency(ms): 5 Avg_Latency(ms): 186 Max_Latency(ms): 120037 histogram: ms: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24+ %: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 100 C:\Program Files (x86)\SQLIO>sqlio -kR -t8 -s120 -o8 -fsequential -b64 -BH -LS c :\TestFile.dat sqlio v1.5.SG using system counter for latency timings, 62500000 counts per second 8 threads reading for 120 secs from file c:\TestFile.dat using 64KB sequential IOs enabling multiple I/Os per thread with 8 outstanding buffering set to use hardware disk cache (but not file cache) using current size: 5120 MB for file: c:\TestFile.dat initialization done CUMULATIVE DATA: throughput metrics: IOs/sec: 1024.07 MBs/sec: 64.00 latency metrics: Min_Latency(ms): 5 Avg_Latency(ms): 61 Max_Latency(ms): 81632 histogram: ms: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24+ %: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 100 Three of the four tests are, to my mind, within reasonable parameters for the rack server. However, the 64 write test is incredibly slow on the rack server. (68 mb/sec on the slow tower vs 21 mb/s on the rack). The read speed for 64k also seems slow. Is this enough to say there is some sort of bottleneck with the shared storage? I need to know if I can take this evidence and say we need to launch an investigation into this. Any help is appreciated.

    Read the article

  • Shared storage setup for Windows

    - by KarmaVille
    This is a n00b question. I want to setup a SAN that will be used as shared storage between multiple Windows 2008 R2 servers. By shared storage, I mean the files can be seen by all servers. How do I do that? Is it possible to implement this without a dedicated Windows file server? (I don't want replication). I'm doing this so that I can setup: http://activemq.apache.org/shared-file-system-master-slave.html

    Read the article

  • How to dump the Subject Alternative Name (SAN) from an SSL certificate file

    - by LonelyPixel
    I know that I can dump the entire information from a PEM certificate file with this command: openssl x509 -in certfile -noout -text And I've already found another direct parameter to show me only the expiry date of a certificate: openssl x509 -in certfile -noout -enddate But is there also a shortcut to get only the alternative names? Like when a certificate can be used for example.com as well as www.example.com. In the full dump, it's here: Certificate: Data: X509v3 extensions: X509v3 Subject Alternative Name: DNS:www.example.com, DNS:example.com I'd just like to save me the hassle to parse this output and get the domain names only. Is that possible? Otherwise, what would be best practices to parse this output? What can be assumed, what may change? Could I use a regexp like X509v3 Subject Alternative Name:\s*DNS:(\S+)(?:, DNS:(\S+))*?

    Read the article

  • How to block some disks from probes on Linux boot?

    - by Igor Velkov
    My linux host connected to SAN with FC interface. It connect with one path, and see some luns, that can't access, because they need anohter path, not available to host. On boot linux probe all lun he can see, get read error on unaccessible luns, and hangs there for a long-long time. Is there a way to disable any access to some luns at boot time, and later? I found a filters for device ignoration for LVM and MULTIPATH, but it not help during boot process. Generally, lvm still affected too despite of filter, and gives me a IO error on every operation like lvdisplay and vgdisplay, but this is another question.

    Read the article

  • CORAID using only 1 of the 2 available NICs for AoE traffic

    - by Peter Carrero
    We got 6 CORAID shelves in my workplace. On 2 of them I see AoE traffic on only 1 of the 2 NICs that are attached to the SAN switch. We got jumbo frames enabled on all devices. Both NICs show up when I issue the aoe-interfaces command. This wouldn't bother me too much if the throughput performance observed on the "bad" shelves using bonnie++ wasn't half of the result of the "good" shelves. The "good" shelves are older SR1521 model and they have ReiserFS on their LUNS - not that I think it makes a difference - and the "bad" shelves are newer SR2421 model and have JFS. Any help as to what is going on and how to rectify this would be greatly appreciated. BTW: even the lower performing shelves outperform another iSCSI device we got, but that is another story... Thanks.

    Read the article

  • just curious if anybody every tried this- hyper-v r2

    - by tony roth
    I have a server that san boots that I want to p2v. I have many options disk2vhd, scvmm etc but I was thinking about cloning the lun (flexclone, netapp) presenting it to my hyper-v r2 server. Within the hv manager do a create new disk then have it copy the cloned lun to a vhd file. Then do the bcdedit\bootsect stuff to it. Should work right? I'm also curious if anybodys booting vhd's that are on bootable luns? I've booted native vhd's just fine was just curious about the running them off a bootable lun. I think that this has quite a few advantages like instant p2v etc.. any thoughts on this? hmm dang as I was typing this I realized that I should not use the hv manager new disk copy routine, I should just disk2vhd the mounted lun. This has advantages in that it should be a lot faster!! thanks

    Read the article

  • Error adding 4tb LUN (Raw Device Mapping) to ESX4 VM

    - by Tom Gardiner
    Hi guys, I'm trying to map an existing 4tb LUN from a Fibre Channel SAN, through to a VM in my ESX4 environment. It keeps telling me that the VMDK file size exceeds the the maximum size supported by the datastore. I've tried in Physical compatibility mode, and also both Virtual styles. I'm a little confused by this as we had the same LUN mapped through to another VM when we were running ESX3.5... I've also noticed that some of my other RAW mappings are generating extremely large VMDK files on the ESX servers. Does anyone know if this change in behaviour is intentional? And if so why? It doesn't seem to me that if the LUN is mapped directly to the VM that it's size should be relevant. We're running 4.0.0 build 236512, and 4.0.0 build 219382 and I've not had any success on either. Any insight or advice would be much appreciated! TG

    Read the article

  • Has anyone used products by StorSimple? [closed]

    - by AlamedaDad
    Their products are storage systems similar to NetApp, but their "hook" is they provide automated tiered storage with the third tier being Cloud providers like Amazon and Azure. They have an interesting story in which they provide primary SAN/iSCSI storage to VMWare and Exchange and at the same time do snaphots to the Cloud. This provides a possible DR option if you have a second system at an alternate location. I was impressed, but I've never heard of them so I'm looking for input and advise on the product. Thanks in advance...

    Read the article

  • What is the best backup solution for VMware Infrastructure system that hosts a wide variety of VMs?

    - by SBWorks
    In a situation where you are running: VMware Infrastructure 4.x with multiple hosts Over 150 VMs with a wide variety of operating systems (Linux in a half dozen distros, Solaris, every MS version, etc.) in multiple languages with almost every mix of installed software (luckily, no Exchange mail servers) Using an EMC fiber channel SAN The VWs that need need to be backed up use about 2 terabytes of data (total) The goal is to keep backups for about 3-months At this rough scale, what backup solutions have worked well for you? And, as an add-on question, did any of them have de-duplication that you thought was effective and useful?

    Read the article

  • Virtual fiber channel HBA in Solaris

    - by Phil
    We are trying to set up some virtual Fibre Channel HBA's in Solaris. This seems to be possible with NPIV. Creating NPIV's in a Solaris global zone works fine, but passing that NPIV to a zone didn't work at all. We tried to pass the NPIV as following: # zonecfg -z zone1 'info' zonename: studentz1 [...] device: match: /devices/pci@0,0/pci8086,25f9@6/pci8086,350c@0,3/pci1077,140@4/fp@1,0:devctl allow-partition not specified allow-raw-io not specified Wat we want to do is, set up an environment for SAN exercises. We don't have a physical host per student, so we try to virtualise that in some way (Solaris zones or VMware). It should be possible to display the WWN of the virtual HBA and mount the storage presented by the disk subsystem. Any ideas to pass the NPIV to a solaris zone or to virtualise this with vmware?

    Read the article

  • Cannot extend existing data disk over 2TB on windows 2008 with dynamic and gpt part

    - by DJYod
    As my D: disk is almost full (2TB) I extended the FC lun to 2.5TB. The new 500Go are seen by windows as "Unalloacted" as expected. I tried to extend the volume but windows says "The is not enough space available on the disk(s) to complete this operation" I read on the web that the disk should be configured as GPT and as a dynamic and it's already a dynamic gpt disk... How can I extend my disk without any data loss? My operating system is Windows 2008 R2 x64 SP1 and the SAN a 3PAR I hope someone can help me :) Thank you very much

    Read the article

  • Multiple iSCSI Targets or 1 that's shared?

    - by Joost Verdaasdonk
    On my network I have several types of files I want to save on a SAN like: SQL db's and logs Exchange data Random files Now I'm wondering if I should create one iSCSI Target with a large volume and initiate that from one of the servers. (and share it so other servers can use it too) Or I should create separate Targets to have each server use its own storage. For the record the storage could be separated because the servers aren't using the shared data. For one reason I was thinking of one storage is ease of backup. (but perhaps performance could be a problem?) What would be an advisable configuration for these type of data?

    Read the article

  • Simple Central Storage for HA mail server

    - by jtnire
    Hi Everyone, I will have 2 Postfix servers. One will be a backup of the other. What is the easiest method to provide central storage to both of these boxes? My infrastructure is very simple: Just a lot of Xen hosts, so there is no SAN or anything. Each Xen host does have RAID1 though. I don't mind mounting NFS shares on each of those mail servers, as long as the NFS server wasn't a single point of failure. Is there such a thing as redundant NFS? Any help would be appreciated Thanks

    Read the article

  • P2v options within a hyper-v environment.

    - by tony roth
    I have a server that san boots that I want to p2v. I have many options disk2vhd, scvmm etc but I was thinking about cloning the lun (flexclone, netapp) presenting it to my hyper-v r2 server. Within the hv manager do a create new disk then have it copy the cloned lun to a vhd file. Then do the bcdedit\bootsect stuff to it. Should work right? I'm also curious if anybodys booting vhd's that are on bootable luns? I've booted native vhd's just fine was just curious about the running them off a bootable lun. I think that this has quite a few advantages like instant p2v etc.. any thoughts on this? hmm dang as I was typing this I realized that I should not use the hv manager new disk copy routine, I should just disk2vhd the mounted lun. This has advantages in that it should be a lot faster!! discovered that disk2vhd may be flaky, crashed the first time I ran it! thanks

    Read the article

  • Booting VM Directly from iSCSI (or FC) in Hyper-V R2

    - by tony roth
    I have a server that san boots that I want to p2v. I have many options disk2vhd, scvmm etc but I was thinking about cloning the lun (flexclone, netapp) presenting it to my hyper-v r2 server. Within the hv manager do a create new disk then have it copy the cloned lun to a vhd file. Then do the bcdedit\bootsect stuff to it. Should work right? I'm also curious if anybodys booting vhd's that are on bootable luns? I've booted native vhd's just fine was just curious about the running them off a bootable lun. I think that this has quite a few advantages like instant p2v etc.. any thoughts on this? hmm dang as I was typing this I realized that I should not use the hv manager new disk copy routine, I should just disk2vhd the mounted lun. This has advantages in that it should be a lot faster!! discovered that disk2vhd may be flaky, crashed the first time I ran it! thanks

    Read the article

  • Xen guests accessing LUNs

    - by mechcow
    We are using RHEL5.3 with a Clarion SAN attached by FC. Our situation is that we have a number of LUNs presented to Hosts and we want to dynamically present the LUNs to Xen Guests. We are not sure on what the best practice approach is to set this up. The Xen guests will form a cluster together and need the LUNs only for data partitions, i.e. when they are actively running services. So one approach would be to always present all disks to all Xen guests, and then rely up on the cluster software, and mount itself, to not mount the disk twice in two locations. This sounds kinda risky and also is not very secure (one cracked guest can see/destroy all the data). Another approach would be to dynamically add and remove the disks from the Xen guests at the dom0 level (using xm block-attach). This could work but sounds slightly complicated, I'm wondering whether Red Hat Cluster Suite supports this in some way or whether there are scripts to do this. Yet another approach would be to have the LUNs endpointed at the Xen guests themselves - I'm not sure whether this is technically possible since the multipathing has to be done at the Host level.

    Read the article

< Previous Page | 3 4 5 6 7 8 9 10 11 12 13 14  | Next Page >