  • Does it make a difference in performance if I use self.fooBar instead of fooBar?

    - by mystify
    Note: I know exactly what a property is. This question is about performance. Using self.fooBar for READ access seems a waste of time for me. Unnecessary Objective-C messaging is going on. The getters typically simply pass along the ivar, so as long as it's pretty sure there will be no reasonable getter method written, I think it's perfectly fine to bypass this heavy guy. Objective-C messaging is about 20 times slower than direct calls. So if there is some high-performance-high-frequency code with hundreds of properties in use, maybe it does help a lot to avoid unnessessary objective-c messaging? Or am I wasting my time thinking about this?

    Read the article

  • W7-pro indexing mydoc on disk partition does not work

    - by Yvan Thery
    I am working on a HP-7100 mini tower running W7 Pro 64bits. My Local HD includes C:/ + 2 disk partitions : all my documents are located on disk partition L:/ and all my media files are on disk partition M:/ The indexing process works well on C:/ and M:/ but does not index the L:/ any more also all of them are allowed to be indexed, also the system is present on all drive security tabs. I have tested to rebuilt the indexing file with a new setting including few directories present on drive C/M/L but still with L: does not work ! One more thing I can tell you is that even after rebuilding the indexing file, I can find some residual directories or files which are out of the test selection. It is like unerased components remaining in the indexing database. As I do not know precisely how the indexing process works it is hard to know what to do ... Recently I had a bad time after using a past restoration procedure ... maybe it did corrupt the indexing file ???? If I start indexing the all L:/ disk partition the system stop at 39 found index also many more are existing .... Does any one from you guys could advise the process to create a new indexing database ... ? Any idea to get out of this mess ? Many thanks for assistance Yvan

    Read the article

  • Un-do Windows disk convert HFS+

    - by BLAKE
    Last night, a friend asked my to give him a copy of a word document. He handed me an external hard drive and left. I plugged the hard drive into my file server running Windows Server 2003, opened disk management and clicked OK. (I know that in Windows 2003 you need to manually assign a drive letter to external drives.) I then looked at the drive in disk management and it said that it was unallocated space. I called my friend and he said that there was data on the drive, but he used it with his Mac Book. Aperantly when I clicked OK in disk management I converted the from HFS+ file system to something else. Is there any way to undo the disk convert? I immediately removed the drive, so there was no writing to it. Windows did not format the drive, it just converted it. Is the data still there? All the data recovery programs I have are for windows, can they read the Mac file system? I need to get the data back, what can I do?

    Read the article

  • How do you optimize database performance when providing results for autocomplete/iterative search?

    - by Howiecamp
    Note: In this question I'm using the term "autocomplete" (or "iterative search") to refer to returning search-as-you-type results, e.g. like Google Search gives you. Also my question is not specific to web applications vs. fat client apps. How are SQL SELECT queries normally constructed to provide decent performance for this type of query, especially over arbitrarily large data sets? In the case where the search will only query based on the first n characters (easiest case) am I still issuing a new SELECT result FROM sometable WHERE entry LIKE... on each keypress. Even with various forms of caching this seems like it might result in poor performance. In cases where you want your search string to return results with prefix matches, substring matches, etc. it's an even more difficult problem. Looking at a case of searching a list of contacts, you might return results that match FirstName + LastName, LastName + FirstName, or any other substring.

    Read the article

  • Why are there performance differences when a SQL function is called from .Net app vs when the same c

    - by Dan Snell
    We are having a problem in our test and dev environments with a function that runs quite slowly at times when called from an .Net Application. When we call this function directly from management studio it works fine. Here are the differences when they are profiled: From the Application: CPU: 906 Reads: 61853 Writes: 0 Duration: 926 From SSMS: CPU: 15 Reads: 11243 Writes: 0 Duration: 31 Now we have determined that when we recompile the function the performance returns to what we are expecting and the performance profile when run from the application matches that of what we get when we run it from SSMS. It will start slowing down again at what appear to random intervals. We have not seen this in prod but they may be in part because everything is recompiled there on a weekly basis. So what might cause this sort of behavior?

    Read the article

  • Un-do Windows disk convert HFS+

    - by BLAKE
    Last night, a friend asked my to give him a copy of a word document. He handed me an external hard drive and left. I plugged the hard drive into my file server running Windows Server 2003, opened disk management and clicked OK. (I know that in Windows 2003 you need to manually assign a drive letter to external drives.) I then looked at the drive in disk management and it said that it was unallocated space. I called my friend and he said that there was data on the drive, but he used it with his Mac Book. Aperantly when I clicked OK in disk management I converted the from HFS+ file system to something else. Is there any way to undo the disk convert? I immediately removed the drive, so there was no writing to it. Windows did not format the drive, it just converted it. Is the data still there? All the data recovery programs I have are for windows, can they read the Mac file system? I need to get the data back, what can I do?

    Read the article

  • How to Audit Database Activity without Performance and Scalability Issues?

    - by GotoError
    I have a need to do auditing all database activity regardless of whether it came from application or someone issuing some sql via other means. So the auditing must be done at the database level. The database in question is Oracle. I looked at doing it via Triggers and also via something called Fine Grained Auditing that Oracle provides. In both cases, we turned on auditing on specific tables and specific columns. However, we found that Performance really sucks when we use either of these methods. Since auditing is an absolute must due to regulations placed around data privacy, I am wondering what is best way to do this without significant performance degradations. If someone has Oracle specific experience with this, it will be helpful but if not just general practices around database activity auditing will be okay as well.

    Read the article

  • Java - Can i have a faster performance for this loop ?

    - by Brad
    I am reading a book and deleting a number of words from it. My problem is that the process takes long time, and i want to make its performance better(Less time), example : Vector<String> pages = new Vector<String>(); // Contains about 1500 page, each page has about 1000 words. Vector<String> wordsToDelete = new Vector<String>(); // Contains about 50000 words. for( String page: pages ) { String pageInLowCase = page.toLowerCase(); for( String wordToDelete: wordsToDelete ) { if( pageInLowCase.contains( wordToDelete ) ) page = page.replaceAll( "(?i)\\b" + wordToDelete + "\\b" , "" ); } // Do some staff with the final page that does not take much time. } This code takes around 3 minutes to execute. If i skipped the loop of replaceAll(...) i can save more than 2 minutes. So is there a way to do the same loop with a faster performance ?

    Read the article

  • Hard Disk DRDY error: is it a crash

    - by pranjal
    I am using IBM Thinkpad, 1.7GHz, 512 RAM with Linux Mint 9 installed. I have two partitions in addition to root. One of the partitions became read-only yesterday, after which I rebooted my system. It is extremely slow along with DRDY Error : Is my Hard disk crashed ? Error Log while booting. Differences between boot sector and its backup. failed command : READ DMA BMDMA : stat 0X25 ata 1.00 : status : { DRDY ERR } ata 1.00 : status :{ UNC } Buffer I/O error on logical device, logical block 65467 smartctl output for the partition: mint mint # smartctl -a /dev/sda1 smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: TOSHIBA MK4026GAX RoHS Serial Number: X5LY1623T Firmware Version: PA107E User Capacity: 40,007,761,920 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 6 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Thu Feb 17 06:48:25 2011 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 153) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 30) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0 2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0 3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 310 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 3968 5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always - 40 7 Seek_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 082 082 000 Old_age Always - 7257 10 Spin_Retry_Count 0x0033 179 100 030 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 3484 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 489 193 Load_Cycle_Count 0x0032 064 064 000 Old_age Always - 367150 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 36 (Lifetime Min/Max 14/57) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 33 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 82 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 1 199 UDMA_CRC_Error_Count 0x0032 200 253 000 Old_age Always - 0 220 Disk_Shift 0x0002 100 100 000 Old_age Always - 101 222 Loaded_Hours 0x0032 085 085 000 Old_age Always - 6146 223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 0 224 Load_Friction 0x0022 100 100 000 Old_age Always - 0 226 Load-in_Time 0x0026 100 100 000 Old_age Always - 227 240 Head_Flying_Hours 0x0001 100 100 001 Pre-fail Offline - 0 SMART Error Log Version: 1 ATA Error Count: 2371 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 2371 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:03:10.061 READ DMA f8 00 00 00 00 00 e0 00 00:03:10.061 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:03:10.053 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:03:10.053 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:03:10.053 READ NATIVE MAX ADDRESS Error 2370 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:03:03.328 READ DMA f8 00 00 00 00 00 e0 00 00:03:03.327 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:03:03.320 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:03:03.319 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:03:03.319 READ NATIVE MAX ADDRESS Error 2369 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:02:56.582 READ DMA f8 00 00 00 00 00 e0 00 00:02:56.582 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:02:56.574 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:02:56.574 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:02:56.574 READ NATIVE MAX ADDRESS Error 2368 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:02:49.809 READ DMA f8 00 00 00 00 00 e0 00 00:02:49.809 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:02:49.801 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:02:49.801 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:02:49.801 READ NATIVE MAX ADDRESS Error 2367 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:02:43.056 READ DMA f8 00 00 00 00 00 e0 00 00:02:43.056 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:02:43.048 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:02:43.048 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:02:43.047 READ NATIVE MAX ADDRESS SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] Device does not support Selective Self Tests/Logging Do I need to get a new Hard Disk my PC ?

    Read the article

  • (0xC03A0014) Failed to add device 'Microsoft Virtual Hard Disk'

    - by maniargaurav
    We had Windows 2008 SP2 Server. It was crashed due to mother board problem. After we got new motherboard we have installed Windows 2008 R2. Now when we try to attach Old VHD File we are getting following issue. Failed to add device 'Microsoft Virtual Hard Disk'. Cannot open attachment 'D:\Test\test.vhd'. Error: 'A virtual disk support provider for the specified file was not found.' TestVM': Cannot open attachment 'D:\Test\test.vhd'. Error: 'A virtual disk support provider for the specified file was not found.' (0xC03A0014). (Virtual machine ID 5626AAB2-C21C-48FF-8B70-40671CBC573B)

    Read the article

  • SQL SERVER – Server Side Paging in SQL Server 2011 – A Better Alternative

    - by pinaldave
    Ranking has improvement considerably from SQL Server 2000 to SQL Server 2005/2008 to SQL Server 2011. Here is the blog article where I wrote about SQL Server 2005/2008 paging method SQL SERVER – 2005 T-SQL Paging Query Technique Comparison (OVER and ROW_NUMBER()) – CTE vs. Derived Table. One can achieve this using OVER clause and ROW_NUMBER() function. Now SQL Server 2011 has come up with the new Syntax for paging. Here is how one can easily achieve it. USE AdventureWorks2008R2 GO DECLARE @RowsPerPage INT = 10, @PageNumber INT = 5 SELECT * FROM Sales.SalesOrderDetail ORDER BY SalesOrderDetailID OFFSET @PageNumber*@RowsPerPage ROWS FETCH NEXT 10 ROWS ONLY GO I consider it good enhancement in terms of T-SQL. I am sure many developers are waiting for this feature for long time. We will consider performance different in future posts. Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, SQL, SQL Authority, SQL Performance, SQL Query, SQL Scripts, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • backup exec - backup to disk offline

    - by Adam
    Hi We are running backup exec 9.1 doing a backup to disk to portable hard disk drives. When we run the backup manually it works fine. But when the backup is setup to run in the evening on a schedule it does not run as the backup to disk folders goes offline and therefore has to be switched back on line. After we have done this the backup runs and completes fine. Any ideas? We have tried leaving the progam open and this makes no difference. Server is Windows 2003 SBS

    Read the article

  • "No bootable device - insert boot disk" after restart on Ubuntu 10.04 b1 update

    - by anjanesh
    I was making an update on my Ubuntu 10.04 beta1 64-bit PC when, after reboot I get PXE-E61: Mediaa test failure, check cable PXE-M0F: Exiting Intel Boot Agent. No bootable device - insert boot disk and press any key How did my boot record disappear ? BIOS Boot Boot Menu Type : Normal Boot Device Priority : <CD/DVD-ROM Drive> <Hard Disk Drive> <Floppy Drive> <Ethernet> Hard Driver Order : No Hard Disk Drive CD/DVD ROM Drive Order : <PT-TSSTcorp CDDV> Removable Drive Order : No Removable Drive Boot to Optical Devices : <Enable> Boot to Removable Devices : <Enable> Boot to Network : <Enable> USB Boot : <Enable>

    Read the article

  • ADNOC talks about 50x increase in performance

    - by KLaker
    If you are still wondering about how Exadata can revolutionise your business then I would recommend watching this great video which was recorded at this year's OpenWorld. First a little background...The Abu Dhabi National Oil Company for Distribution (ADNOC) is an integrated energy company that was founded in 1973. ADNOC Distribution markets and distributes petroleum products and services within the United Arab Emirates and internationally. As one of the largest and most innovative government-owned petroleum companies in the Arab Gulf, ADNOC Distribution is renowned and respected for the exceptional quality and reliability of its products and services. Its five corporate divisions include more than 200 filling stations (a number that is growing at 8% annually), more than 150 convenience stores, 10 vehicle inspection stations, as well as wholesale and retail sales of bulk fuel, gas, oil, diesel, and lubricants. ADNOC selected Oracle Exadata Database Machine after extensive research because it provided them with a single platform that can run mixed workloads in a single unified machine: "We chose Oracle Exadata Database Machine because it.offered a fully integrated and highly engineered system that was ready to deploy. With our infrastructure running all the same technology, we can operate any type of Oracle Database without restrictions and be prepared for business growth," said Ali Abdul Aziz Al-Ali, IT division manager, ADNOC Distribution. ".....we could consolidate our transaction processing and business intelligence onto one platform. Competing solutions are just not capable of doing that." - Awad Ahmed Ali El-Sidiq, Senior Database Administrator, ADNOC Distribution In this new video Awad Ahmen Ali El Sidddig, Senior DBA at ADNOC, talks about the impact that Exadata has had on his team and the whole business. ADNOC is using our engineered systems to drive and manage all their workloads: from transaction systems to payments system to data warehouse to BI environment. A true Disk-to-Dashboard revolution using Engineered Systems. This engineered approach is delivering 50x improvement in performance with one queries running 100x faster! The IT has even revolutionised some of their data warehouse related processes with the help of Exadata and now jobs that were taking over 4 hours now run in a few minutes.  To watch the video click on the image below which will take you to our Oracle YouTube page: (if the above link does not work, click here: http://www.youtube.com/watch?v=zcRpxc6u5Ic) Now that queries are running 100x faster and jobs are completing in minutes not hours, what is next for the IT team at ADNOC? Like many of our customers ADNOC is now looking to take advantage of big data to help them better align their business operations with customer behaviour and customer insights. To help deliver this next level of insight the IT team is looking at the new features in Oracle Database 12c such as the new in-memory feature to deliver even more performance gains.  The great news is that Awad Ahmen Ali El Sidddig was awarded DBA of the Year - EMEA within our Data Warehouse Global Leaders programme and you can see the badge for this award pop-up at the start of video. Well done to everyone at ADNOC and thanks for spending the time with us at OOW to create this great video.

    Read the article

  • System locking up with suspicious messages about hard disk

    - by Chris Conway
    My system has started behaving strangely, intermittently locking up. I see messages like the following in syslog: Nov 18 22:22:00 claypool kernel: [ 3428.078156] ata3.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x0 Nov 18 22:22:00 claypool kernel: [ 3428.078163] ata3.00: irq_stat 0x40000000 Nov 18 22:22:00 claypool kernel: [ 3428.078167] sr 2:0:0:0: CDB: Test Unit Ready: 00 00 00 00 00 00 Nov 18 22:22:00 claypool kernel: [ 3428.078182] ata3.00: cmd a0/00:00:00:00:00/00:00:00:00:00/a0 tag 0 Nov 18 22:22:00 claypool kernel: [ 3428.078184] res 50/00:03:00:00:00/00:00:00:00:00/a0 Emask 0x1 (device error) Nov 18 22:22:00 claypool kernel: [ 3428.078188] ata3.00: status: { DRDY } Nov 18 22:22:00 claypool kernel: [ 3428.080887] ata3.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x0 Nov 18 22:22:00 claypool kernel: [ 3428.080890] ata3.00: irq_stat 0x40000000 Nov 18 22:22:00 claypool kernel: [ 3428.080893] sr 2:0:0:0: CDB: Test Unit Ready: 00 00 00 00 00 00 Nov 18 22:22:00 claypool kernel: [ 3428.080905] ata3.00: cmd a0/00:00:00:00:00/00:00:00:00:00/a0 tag 0 Nov 18 22:22:00 claypool kernel: [ 3428.080906] res 50/00:03:00:00:00/00:00:00:00:00/a0 Emask 0x1 (device error) Nov 18 22:22:00 claypool kernel: [ 3428.080910] ata3.00: status: { DRDY } And then this: Nov 18 23:13:56 claypool kernel: [ 6544.000798] ata1.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen Nov 18 23:13:56 claypool kernel: [ 6544.000804] ata1.00: failed command: FLUSH CACHE EXT Nov 18 23:13:56 claypool kernel: [ 6544.000814] ata1.00: cmd ea/00:00:00:00:00/00:00:00:00:00/a0 tag 0 Nov 18 23:13:56 claypool kernel: [ 6544.000815] res 40/00:00:00:4f:c2/00:00:00:00:00/40 Emask 0x4 (timeout) Nov 18 23:13:56 claypool kernel: [ 6544.000819] ata1.00: status: { DRDY } Nov 18 23:13:56 claypool kernel: [ 6544.000825] ata1: hard resetting link Nov 18 23:14:01 claypool kernel: [ 6549.360324] ata1: link is slow to respond, please be patient (ready=0) Nov 18 23:14:06 claypool kernel: [ 6554.008091] ata1: COMRESET failed (errno=-16) Nov 18 23:14:06 claypool kernel: [ 6554.008103] ata1: hard resetting link Nov 18 23:14:11 claypool kernel: [ 6559.372246] ata1: link is slow to respond, please be patient (ready=0) Nov 18 23:14:16 claypool kernel: [ 6564.020228] ata1: COMRESET failed (errno=-16) Nov 18 23:14:16 claypool kernel: [ 6564.020235] ata1: hard resetting link Nov 18 23:14:21 claypool kernel: [ 6569.380109] ata1: link is slow to respond, please be patient (ready=0) Nov 18 23:14:31 claypool kernel: [ 6579.460243] ata1: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Nov 18 23:14:31 claypool kernel: [ 6579.486595] ata1.00: configured for UDMA/133 Nov 18 23:14:31 claypool kernel: [ 6579.486601] ata1.00: retrying FLUSH 0xea Emask 0x4 Nov 18 23:14:31 claypool kernel: [ 6579.486939] ata1.00: device reported invalid CHS sector 0 Nov 18 23:14:31 claypool kernel: [ 6579.486952] ata1: EH complete Nov 18 23:17:01 claypool CRON[3910]: (root) CMD ( cd / && run-parts --report /etc/cron.hourly) Nov 18 23:17:01 claypool CRON[3908]: (CRON) error (grandchild #3910 failed with exit status 1) Nov 18 23:17:01 claypool postfix/sendmail[3925]: fatal: open /etc/postfix/main.cf: No such file or directory Nov 18 23:17:01 claypool CRON[3908]: (root) MAIL (mailed 1 byte of output; but got status 0x004b, #012) Nov 18 23:39:01 claypool CRON[4200]: (root) CMD ( [ -x /usr/lib/php5/maxlifetime ] && [ -d /var/lib/php5 ] && find /var/lib/php5/ -type f -cmin +$(/usr/lib/php5/maxlifetime) -print0 | xargs -n 200 -r -0 rm) There are no messages marked after 23:39. When I next tried to use the machine, it would not return from the screensaver (blank screen), nor switch to another terminal, and I had to hard reboot it. [UPDATE] The output of smartctl is here. I had trouble getting this, because / is being mounted read-only (?!), which prevents most applications from running. Also, it may not be related, but I have the following worrying messages in dmesg: [ 10.084596] k8temp 0000:00:18.3: Temperature readouts might be wrong - check erratum #141 [ 10.098477] i2c i2c-0: nForce2 SMBus adapter at 0x600 [ 10.098483] ACPI: resource nForce2_smbus [io 0x0700-0x073f] conflicts with ACPI region SM00 [??? 0x00000700-0x0000073f flags 0x30] [ 10.098486] ACPI: This conflict may cause random problems and system instability [ 10.098487] ACPI: If an ACPI driver is available for this device, you should use it instead of the native driver [ 10.098509] i2c i2c-1: nForce2 SMBus adapter at 0x700 [ 10.112570] Linux agpgart interface v0.103 [ 10.155329] atk: Resources not safely usable due to acpi_enforce_resources kernel parameter [ 10.161506] it87: Found IT8712F chip at 0x290, revision 8 [ 10.161517] it87: VID is disabled (pins used for GPIO) [ 10.161527] it87: in3 is VCC (+5V) [ 10.161528] it87: in7 is VCCH (+5V Stand-By) [ 10.161560] ACPI: resource it87 [io 0x0295-0x0296] conflicts with ACPI region ECRE [??? 0x00000290-0x000002af flags 0x45] [ 10.161562] ACPI: This conflict may cause random problems and system instability [ 10.161564] ACPI: If an ACPI driver is available for this device, you should use it instead of the native driver [UPDATE 2] I swapped in a new SATA cable, per Phil's suggestion. The current output of smartctl is here, if it helps. [UPDATE 3] I don't think the cable fixed it. The system hasn't locked up yet, but my media player crashed a few minutes ago and I have the following in the syslog: Nov 20 16:07:17 claypool kernel: [ 2294.400033] ata1: link is slow to respond, please be patient (ready=0) Nov 20 16:07:47 claypool kernel: [ 2324.084581] ata1: COMRESET failed (errno=-16) Nov 20 16:07:47 claypool kernel: [ 2324.084588] ata1: limiting SATA link speed to 1.5 Gbps Nov 20 16:07:47 claypool kernel: [ 2324.084592] ata1: hard resetting link I get the following response from smartctl: $ sudo smartctl -a /dev/sda [sudo] password for chris: sudo: Can't open /var/lib/sudo/chris/0: Read-only file system smartctl 5.40 2010-03-16 r3077 [i686-pc-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Device: /0:0:0:0 Version: scsiModePageOffset: response length too short, resp_len=47 offset=50 bd_len=46 >> Terminate command early due to bad response to IEC mode page A mandatory SMART command failed: exiting. To continue, add one or more '-T permissive' options.

    Read the article

  • JIT compiler for C, C++, and the likes

    - by Ebrahim
    Is there any just-in-time compiler out there for compiled languages, such as C and C++? (The first names that come to mind are Clang and LLVM! But I don't think they currently support it.) Explanation: I think the software could benefit from runtime profiling feedback and aggressively optimized recompilation of hotspots at runtime, even for compiled-to-machine languages like C and C++. Profile-guided optimization does a similar job, but with the difference a JIT would be more flexible in different environments. In PGO you run your binary prior to releasing it. After you released it, it would use no environment/input feedbacks collected at runtime. So if the input pattern is changed, it is probe to performance penalty. But JIT works well even in that conditions. However I think it is controversial wether the JIT compiling performance benefit outweights its own overhead. Edit: Grammar

    Read the article

  • Enterprise Performance Management: Driving Management Excellence

    Extending operational excellence to management excellence is the new strategic imperative for organizations large and small, all around the world. Management Excellence is a strategy for organizations to differentiate from their competition, by being smarter, more agile and more aligned. Tune into this conversation with John Kopcke, Senior Vice President of Oracle’s Enterprise Performance Management Global Business Unit to learn how leading companies are integrating their management processes and using Oracle’s EPM System to achieve management excellence.

    Read the article

  • Advanced MySQL Replication - Improving Performance

    MySQL Replication can be made quite reliable and robust if the right tools are used to keep it running smoothly--but what if enormous loads on the primary server are overloading the slave server. Are there ways to speed up performance, so the slave can keep up?

    Read the article

  • Virtual Disk Service Loader has stopped working

    - by Leigh Riffel
    We have several relatively recent (less than 1 week) installations of Windows Server 2008 R2 Enterprise that are getting this error whenever we open Disk Management. The application name is vdsldr.exe and the Problem Event Name is BEX64. The windows firewall was turned off and the service disabled. The Virtual Disk service was started (identical results when it is stopped). The computers are virtual machines running on VSphere, so that could be part of the problem. The strange thing is that Disk Manager worked fine when the VMs were first created.

    Read the article

  • SQL SERVER – DMV – sys.dm_exec_query_optimizer_info – Statistics of Optimizer

    - by pinaldave
    Incredibly, SQL Server has so much information to share with us. Every single day, I am amazed with this SQL Server technology. Sometimes I find several interesting information by just querying few of the DMV. And when I present this info in front of my client during performance tuning consultancy, they are surprised with my findings. Today, I am going to share one of the hidden gems of DMV with you, the one which I frequently use to understand what’s going on under the hood of SQL Server. SQL Server keeps the record of most of the operations of the Query Optimizer. We can learn many interesting details about the optimizer which can be utilized to improve the performance of server. SELECT * FROM sys.dm_exec_query_optimizer_info WHERE counter IN ('optimizations', 'elapsed time','final cost', 'insert stmt','delete stmt','update stmt', 'merge stmt','contains subquery','tables', 'hints','order hint','join hint', 'view reference','remote query','maximum DOP', 'maximum recursion level','indexed views loaded', 'indexed views matched','indexed views used', 'indexed views updated','dynamic cursor request', 'fast forward cursor request') All occurrence values are cumulative and are set to 0 at system restart. All values for value fields are set to NULL at system restart. I have removed a few of the internal counters from the script above, and kept only documented details. Let us check the result of the above query. As you can see, there is so much vital information that is revealed in above query. I can easily say so many things about how many times Optimizer was triggered and what the average time taken by it to optimize my queries was. Additionally, I can also determine how many times update, insert or delete statements were optimized. I was able to quickly figure out that my client was overusing the Query Hints using this dynamic management view. If you have been reading my blog, I am sure you are aware of my series related to SQL Server Views SQL SERVER – The Limitations of the Views – Eleven and more…. With this, I can take a quick look and figure out how many times Views were used in various solutions within the query. Moreover, you can easily know what fraction of the optimizations has been involved in tuning server. For example, the following query would tell me, in total optimizations, what the fraction of time View was “reference“. As this View also includes system Views and DMVs, the number is a bit higher on my machine. SELECT (SELECT CAST (occurrence AS FLOAT) FROM sys.dm_exec_query_optimizer_info WHERE counter = 'view reference') / (SELECT CAST (occurrence AS FLOAT) FROM sys.dm_exec_query_optimizer_info WHERE counter = 'optimizations') AS ViewReferencedFraction Reference : Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, PostADay, SQL, SQL Authority, SQL DMV, SQL Optimization, SQL Performance, SQL Query, SQL Scripts, SQL Server, SQL Tips and Tricks, SQLServer, T SQL, Technology

    Read the article

  • Performance Tuning Tips for Apache

    Apache is one of the most successful open source projects of our times. A big advantage of this popularity is that over the years people have spent a great deal of time fine tuning the software for better performance. Read on to learn more.

    Read the article

  • Beeping Hard Disk - Seagate 250GB Momentus 5400.6

    - by Pez Cuckow
    I have been trying to repair a laptop that simply beeps instead of booting. After taking it apart I have now realised that it is the hard disk beeping. I know that may sound strange but I guarantee that is what it is! (Currently powered on it's own with a Sata Mains lead). The beeping is slightly faster than one per second there is a link to this recording. This recording was made resting the mic on the hard disk while it was sat on a table on it's own, there are no speakers anywhere near, the sound is coming from the hard disk. Does anyone know what this beep means? Is the hard drive just dead, or is it fixable and the data recoverable? Many thanks,

    Read the article

  • Add physical disk to KVM virtual machine

    - by evan
    I'm setting up a file server (nas4free) as a KVM virtual machine on a Ubuntu Server 12.04 system. How do I add physical hard drives directly to the VM so they can be used by the guest (nas4free), but not the host? Specifically the hard drive I'd like to mount is /dev/sda (which is not currently mounted on the server.) So far I've found two solutions but I haven't gotten either to work. The first is from Server Fault where it's suggested to use virt-manager. I haven't gotent this to work because when I try to select an existing drive nothing is being listed. My best guess as to why this is, is because I'm using virt-manager over ssh and not connecting as root, should that make a difference? The second solution I've found here is to just run the command (modified for my system) qm set nas4free -virtio /dev/sda but that seems to require proxmox which I don't have installed and doesn't seem to be in the default repositories? Finally, once the above is sorted out and I can mount the drive directly to the VM, does anyone have an experience with whether the drive should be mounted to the VM as scsi, ide, or virtio? (I know virtio was recommend in the linked ServerFault page, but I hadn't heard of it before now since I mainly use VMWare). Thanks for your help!!!

    Read the article