Search Results

Search found 29364 results on 1175 pages for 'powerpivot self service r'.

Page 71/1175 | < Previous Page | 67 68 69 70 71 72 73 74 75 76 77 78  | Next Page >

  • Python Socket Getting Connection Reset

    - by Ian
    I created a threaded socket listener that stores newly accepted connections in a queue. The socket threads then read from the queue and respond. For some reason, when doing benchmarking with 'ab' (apache benchmark) using a concurrency of 2 or more, I always get a connection reset before it's able to complete the benchmark (this is taking place locally, so there's no external connection issue). class server: _ip = '' _port = 8888 def __init__(self, ip=None, port=None): if ip is not None: self._ip = ip if port is not None: self._port = port self.server_listener(self._ip, self._port) def now(self): return time.ctime(time.time()) def http_responder(self, conn, addr): httpobj = http_builder() httpobj.header('HTTP/1.1 200 OK') httpobj.header('Content-Type: text/html; charset=UTF-8') httpobj.header('Connection: close') httpobj.body("Everything looks good") data = httpobj.generate() sent = conn.sendall(data) def http_thread(self, id): self.log("THREAD %d: Starting Up..." % id) while True: conn, addr = self.q.get() ip, port = addr self.log("THREAD %d: responding to request: %s:%s - %s" % (id, ip, port, self.now())) self.http_responder(conn, addr) self.q.task_done() conn.close() def server_listener(self, host, port): self.q = Queue.Queue(0) sock = socket.socket(socket.AF_INET, socket.SOCK_STREAM) sock.bind( (host, port) ) sock.listen(5) for i in xrange(4): #thread count thread.start_new(self.http_thread, (i+1, )) while True: self.q.put(sock.accept()) sock.close() server('', 9999) When running the benchmark, I get totally random numbers of good requests before it errors out, usually between 4 and 500. Edit: Took me a while to figure it out, but the problem was in sock.listen(5). Because I was using apache benchmark with a higher concurrency (5 and up) it was causing the backlog of connections to pile up, at which point the connections started getting dropped by the socket.

    Read the article

  • WCF Host as windows service faults

    - by pdiddy
    I have this WCF service running as a window service. I have in my code that everytime it faults it will restart the service. Now I'm having the issue where the host faults, it tries to restarts, then faults again, but at some point it just stop the service. Wondering why it stop the service? Is this something handled by the OS that it detects the service has faulted a number of time within a certain time it will just stop the service because it faulted too many time ?

    Read the article

  • How to get a service to listen on port 80 on Windows Server 2003

    - by Miky D
    I've coded a custom windows service that listens on TCP port 80 but when I try to install it on a Windows Server 2003 machine it fails to start because some other service is already listening on that port. So far I've disabled the IIS Admin service and the HTTP SSL service but no luck. When I run netstat -a -n -o | findstr 0.0:80 it gives me the process id 4 as the culprit, but when I look at the running processes that process id points to the "System" process. What can I do to get the System process to stop listening on port 80 and get my service to listen instead? P.S. I should point out that the service runs fine if I install it on my Windows XP or Windows 7 development boxes. Also, I should specify that this has nothing to do with it being a service. I've tried starting a regular application that attempts to bing to port 80 on the Windows Server 2003 with the same outcome - it fails because another application is already bound to that port.

    Read the article

  • Service design or access to another process

    - by hotyi
    I have a cache service,it's works as .net remoting, i want to create another windows service to clean up the that cache service by transfer the objects from cache to files. because they are in separate process, is their any way i could access that cache service or do i have to expose a method from the cache service to do that clean up work? the "clean up" means i want to serialize the object from Cache to file and these saved file will be used for further process. let me explain this application more detail. the application is mainly a log service to log all the coming request and these request will be saved to db for further data mining. we have 2 design for this log system 1) use MSMQ, but seems it's performance is not good enough, we don't use it. 2) we design a cache service, each request will be saved into the cache, and we need another function to clean up the cache by serialize the object to file.

    Read the article

  • how to create Cross domain asp.net web service

    - by Prithvi Raj Nandiwal
    i have create a web service. i want to access this web service using Ajax jqury. i am able to access on same domain. but i want to access thia web service to another domain. Have any one idea. how to create cross domain web service in asp.net. any setting in web,config file so that i access it on another domain. my webservice [WebService(Namespace = "http://tempuri.org/")] [System.Web.Script.Services.ScriptService] public class Service : System.Web.Services.WebService { public Service () { } [WebMethod] public string SetName(string name) { return "hello my dear friend " + name; } } JavaScript $.ajax({ type: "GET", url:'http://192.168.1.119/Service/SetName.asmx?name=pr', ContentType: "application/x-www-form-urlencoded", cache: false, dataType: "jsonp", success: onSuccess });

    Read the article

  • PyQt QAbstractListModel seems to ignore tristate flags

    - by mcieslak
    I've been trying for a couple days to figure out why my QAbstractLisModel won't allow a user to toggle a checkable item in three states. The model returns the Qt.IsTristate and Qt.ItemIsUserCheckable in the flags() method, but when the program runs only Qt.Checked and Qt.Unchecked are toggled on edit. class cboxModel(QtCore.QAbstractListModel): def __init__(self, parent=None): super(cboxModel, self).__init__(parent) self.cboxes = [ ['a',0], ['b',1], ['c',2], ['d',0] ] def rowCount(self,index=QtCore.QModelIndex()): return len(self.cboxes) def data(self,index,role): if not index.isValid: return QtCore.QVariant() myname,mystate = self.cboxes[index.row()] if role == QtCore.Qt.DisplayRole: return QtCore.QVariant(myname) if role == QtCore.Qt.CheckStateRole: if mystate == 0: return QtCore.QVariant(QtCore.Qt.Unchecked) elif mystate == 1: return QtCore.QVariant(QtCore.Qt.PartiallyChecked) elif mystate == 2: return QtCore.QVariant(QtCore.Qt.Checked) return QtCore.QVariant() def setData(self,index,value,role=QtCore.Qt.EditRole): if index.isValid(): self.cboxes[index.row()][1] = value.toInt()[0] self.emit(QtCore.SIGNAL("dataChanged(QModelIndex,QModelIndex)"), index, index) print self.cboxes return True return False def flags(self,index): if not index.isValid(): return QtCore.Qt.ItemIsEditable return QtCore.Qt.ItemIsEnabled | QtCore.Qt.ItemIsEditable | QtCore.Qt.ItemIsUserCheckable | QtCore.Qt.ItemIsTristate You can test it with this, class MainForm(QtGui.QMainWindow): def __init__(self, parent=None): super(MainForm, self).__init__(parent) model = cboxModel(self) self.view = QtGui.QListView() self.view.setModel(model) self.setCentralWidget(self.view) app = QtGui.QApplication(sys.argv) form = MainForm() form.show() app.exec_() and see that only 2 states are available. I'm assuming there's something simple I'm missing. Any ideas? Thanks!

    Read the article

  • My C# program running as Windows Service is blocking Windows XP from hibernation

    - by sherpa
    I have Windows Service written in C#. It starts two threads, one is pooling a Web Service, second is waiting on a Monitor object for a new job to arrive. Besides that, the main thread acts as a WCF service host using NetNamedPipeBinding. It lets the client application to register a callback and then sends notifications back. The problem I have is that when this Windows Service is running, I cannot hibernate or Standby my computer which is running on Windows XP, SP3. When I set Windows to hibernate or standby, nothing happens. Then, at the moment when I go to Service Manager and stop the service, the system hibernation starts immediately. The service class extending the ServiceBase has properties like CanHandlePowerEvent, CanPauseAndContinue, etc. set to true... That didn't make any difference. The question is: what can be blocking the Hibernation/Standby from proceeding? What should I take care about to avoid it?

    Read the article

  • Pass in a value into Python Class through command line

    - by chrissygormley
    Hello, I have got some code to pass in a variable into a script from the command line. The script is: import sys, os def function(var): print var class function_call(object): def __init__(self, sysArgs): try: self.function = None self.args = [] self.modulePath = sysArgs[0] self.moduleDir, tail = os.path.split(self.modulePath) self.moduleName, ext = os.path.splitext(tail) __import__(self.moduleName) self.module = sys.modules[self.moduleName] if len(sysArgs) > 1: self.functionName = sysArgs[1] self.function = self.module.__dict__[self.functionName] self.args = sysArgs[2:] except Exception, e: sys.stderr.write("%s %s\n" % ("PythonCall#__init__", e)) def execute(self): try: if self.function: self.function(*self.args) except Exception, e: sys.stderr.write("%s %s\n" % ("PythonCall#execute", e)) if __name__=="__main__": test = test() function_call(sys.argv).execute() This works by entering ./function <function> <arg1 arg2 ....>. The problem is that I want to to select the function I want that is in a class rather than just a function by itself. The code I have tried is the same except that function(var): is in a class. I was hoping for some ideas on how to modify my function_call class to accept this. Thanks for any help.

    Read the article

  • How to use Devicemotion/Gyroscope to move a dot from center to 8 directions of iphone screen

    - by iSeeker
    I am trying to move a dot at center to 8 directions of iphone screen using Devicemotion such that it moves faster when tilted at a faster rate. Rough sketch is below: I could find a similar implementation in an app called Gyrododge in appstore, i cant figure out how to make it work... Update: This is what i have done so far, but the response is not smooth, and is very jittery.. xdiff and ydiff are the change of device attitude in x and y directions, derived from quatenion implementation. if (currDeviceMotion.rotationRate.x < -2) { NSLog(@"To Top"); if (195+800*ydiff >=193 && 195+800*ydiff <= 197) { [self.pitchDot setFrame:CGRectMake(150, 195, 20, 20)]; }else{ if (195+800*ydiff >=390 ) { [self.pitchDot setFrame:CGRectMake(150, 390, 20, 20)]; }else if (195+800*ydiff <= 0){ [self.pitchDot setFrame:CGRectMake(150, 0, 20, 20)]; }else if(195+800*ydiff < 194){ [self.pitchDot setFrame:CGRectMake(150, 195+800*ydiff, 20, 20)]; }else if(195+800*ydiff > 196){ [self.pitchDot setFrame:CGRectMake(150, 195+800*ydiff, 20, 20)]; } } }else if (currDeviceMotion.rotationRate.x > 2){ NSLog(@"To Bottom"); if (195+800*ydiff >=193 && 195+800*ydiff <= 197) { [self.pitchDot setFrame:CGRectMake(150, 195, 20, 20)]; }else{ if (195+800*ydiff >=390 ) { [self.pitchDot setFrame:CGRectMake(150, 390, 20, 20)]; }else if (195+800*ydiff <= 0){ [self.pitchDot setFrame:CGRectMake(150, 0, 20, 20)]; }else if(195+800*ydiff < 194){ [self.pitchDot setFrame:CGRectMake(150, 195+800*ydiff, 20, 20)]; }else if(195+800*ydiff > 196){ [self.pitchDot setFrame:CGRectMake(150, 195+800*ydiff, 20, 20)]; } } }else if (currDeviceMotion.rotationRate.y < -2){ NSLog(@"To Left"); if (150+500*xdiff >= 148 && 150+500*xdiff <=152) { [self.pitchDot setFrame:CGRectMake(150, 195, 20, 20)]; }else{ if (150+500*xdiff >= 300 ) { [self.pitchDot setFrame:CGRectMake(300, 195, 20, 20)]; }else if (150+500*xdiff <= 0){ [self.pitchDot setFrame:CGRectMake(0, 195, 20, 20)]; }else if(150+500*xdiff < 148){ [self.pitchDot setFrame:CGRectMake(150+500*xdiff, 195, 20, 20)]; }else if(150+500*xdiff > 152){ [self.pitchDot setFrame:CGRectMake(150+500*xdiff, 195, 20, 20)]; } } }else if (currDeviceMotion.rotationRate.y > 2){ NSLog(@"To Right"); if (150+500*xdiff >= 148 && 150+500*xdiff <=152) { [self.pitchDot setFrame:CGRectMake(150, 195, 20, 20)]; }else{ if (150+500*xdiff >= 300 ) { [self.pitchDot setFrame:CGRectMake(300, 195, 20, 20)]; }else if (150+500*xdiff <= 0){ [self.pitchDot setFrame:CGRectMake(0, 195, 20, 20)]; }else if(150+500*xdiff < 148){ [self.pitchDot setFrame:CGRectMake(150+500*xdiff, 195, 20, 20)]; }else if(150+500*xdiff > 152){ [self.pitchDot setFrame:CGRectMake(150+500*xdiff, 195, 20, 20)]; } } }else if (currDeviceMotion.rotationRate.x < -0.20 && currDeviceMotion.rotationRate.y > 0.20 ){ NSLog(@"To Diagonal Right Top"); if (150+650*xdiff >= 148 && 150+650*xdiff <=152) { [self.pitchDot setFrame:CGRectMake(150, 195, 20, 20)]; }else{ if (150+650*xdiff >= 300 ) { [self.pitchDot setFrame:CGRectMake(300, 0, 20, 20)]; }else if(150+650*xdiff > 152){ [self.pitchDot setFrame:CGRectMake(150+650*xdiff, 195-1.3*650*xdiff, 20, 20)]; } } }else if (currDeviceMotion.rotationRate.x > 0.20 && currDeviceMotion.rotationRate.y < -0.20 ){ NSLog(@"To Diagonal Left Bottom"); if (150+650*xdiff >= 148 && 150+650*xdiff <=152) { [self.pitchDot setFrame:CGRectMake(150, 195, 20, 20)]; }else{ if (150+650*xdiff <= 0 ) { [self.pitchDot setFrame:CGRectMake(0, 390, 20, 20)]; }else if(150+650*xdiff < 148){ [self.pitchDot setFrame:CGRectMake(150+650*xdiff, 195-1.3*650*xdiff, 20, 20)]; } } }else if (currDeviceMotion.rotationRate.x < -0.20 && currDeviceMotion.rotationRate.y < -0.20 ){ NSLog(@"To Diagonal Left Top and xdiff is %f",xdiff); if (150+650*xdiff >= 148 && 150+650*xdiff <=152) { [self.pitchDot setFrame:CGRectMake(150, 195, 20, 20)]; }else{ if (150+650*xdiff <= 0 ) { [self.pitchDot setFrame:CGRectMake(0, 0, 20, 20)]; }else if(150+650*xdiff < 148){ [self.pitchDot setFrame:CGRectMake(150+650*xdiff, 195+1.3*650*xdiff, 20, 20)]; } } }else if (currDeviceMotion.rotationRate.x > 0.20 && currDeviceMotion.rotationRate.y > 0.20 ){ NSLog(@"To Diagonal Right Bottom"); if (150+650*xdiff >= 148 && 150+650*xdiff <=152) { [self.pitchDot setFrame:CGRectMake(150, 195, 20, 20)]; }else{ if (150+650*xdiff >= 300 ) { [self.pitchDot setFrame:CGRectMake(300, 390, 20, 20)]; }else if(150+650*xdiff > 152){ [self.pitchDot setFrame:CGRectMake(150+650*xdiff, 195+1.3*650*xdiff, 20, 20)]; } } }else if((currDeviceMotion.rotationRate.x < 0.20 && currDeviceMotion.rotationRate.x < -0.20) ||(currDeviceMotion.rotationRate.y < 0.20 && currDeviceMotion.rotationRate.y < -0.20) ||(currDeviceMotion.rotationRate.z < 0.20 && currDeviceMotion.rotationRate.z < -0.20)){ [self.rollDot setFrame:CGRectMake(150, 195, 20, 20)]; [self.pitchDot setFrame:CGRectMake(150, 195, 20, 20)]; } It could be great if i could make it move like the application i have stated above, called Gyrododge This link also addresses a similar question:Link. Any advice or help is greatly appreciated... Thanks.

    Read the article

  • Scaling-out Your Services by Message Bus based WCF Transport Extension &ndash; Part 1 &ndash; Background

    - by Shaun
    Cloud computing gives us more flexibility on the computing resource, we can provision and deploy an application or service with multiple instances over multiple machines. With the increment of the service instances, how to balance the incoming message and workload would become a new challenge. Currently there are two approaches we can use to pass the incoming messages to the service instances, I would like call them dispatcher mode and pulling mode.   Dispatcher Mode The dispatcher mode introduces a role which takes the responsible to find the best service instance to process the request. The image below describes the sharp of this mode. There are four clients communicate with the service through the underlying transportation. For example, if we are using HTTP the clients might be connecting to the same service URL. On the server side there’s a dispatcher listening on this URL and try to retrieve all messages. When a message came in, the dispatcher will find a proper service instance to process it. There are three mechanism to find the instance: Round-robin: Dispatcher will always send the message to the next instance. For example, if the dispatcher sent the message to instance 2, then the next message will be sent to instance 3, regardless if instance 3 is busy or not at that moment. Random: Dispatcher will find a service instance randomly, and same as the round-robin mode it regardless if the instance is busy or not. Sticky: Dispatcher will send all related messages to the same service instance. This approach always being used if the service methods are state-ful or session-ful. But as you can see, all of these approaches are not really load balanced. The clients will send messages at any time, and each message might take different process duration on the server side. This means in some cases, some of the service instances are very busy while others are almost idle. For example, if we were using round-robin mode, it could be happened that most of the simple task messages were passed to instance 1 while the complex ones were sent to instance 3, even though instance 1 should be idle. This brings some problem in our architecture. The first one is that, the response to the clients might be longer than it should be. As it’s shown in the figure above, message 6 and 9 can be processed by instance 1 or instance 2, but in reality they were dispatched to the busy instance 3 since the dispatcher and round-robin mode. Secondly, if there are many requests came from the clients in a very short period, service instances might be filled by tons of pending tasks and some instances might be crashed. Third, if we are using some cloud platform to host our service instances, for example the Windows Azure, the computing resource is billed by service deployment period instead of the actual CPU usage. This means if any service instance is idle it is wasting our money! Last one, the dispatcher would be the bottleneck of our system since all incoming messages must be routed by the dispatcher. If we are using HTTP or TCP as the transport, the dispatcher would be a network load balance. If we wants more capacity, we have to scale-up, or buy a hardware load balance which is very expensive, as well as scaling-out the service instances. Pulling Mode Pulling mode doesn’t need a dispatcher to route the messages. All service instances are listening to the same transport and try to retrieve the next proper message to process if they are idle. Since there is no dispatcher in pulling mode, it requires some features on the transportation. The transportation must support multiple client connection and server listening. HTTP and TCP doesn’t allow multiple clients are listening on the same address and port, so it cannot be used in pulling mode directly. All messages in the transportation must be FIFO, which means the old message must be received before the new one. Message selection would be a plus on the transportation. This means both service and client can specify some selection criteria and just receive some specified kinds of messages. This feature is not mandatory but would be very useful when implementing the request reply and duplex WCF channel modes. Otherwise we must have a memory dictionary to store the reply messages. I will explain more about this in the following articles. Message bus, or the message queue would be best candidate as the transportation when using the pulling mode. First, it allows multiple application to listen on the same queue, and it’s FIFO. Some of the message bus also support the message selection, such as TIBCO EMS, RabbitMQ. Some others provide in memory dictionary which can store the reply messages, for example the Redis. The principle of pulling mode is to let the service instances self-managed. This means each instance will try to retrieve the next pending incoming message if they finished the current task. This gives us more benefit and can solve the problems we met with in the dispatcher mode. The incoming message will be received to the best instance to process, which means this will be very balanced. And it will not happen that some instances are busy while other are idle, since the idle one will retrieve more tasks to make them busy. Since all instances are try their best to be busy we can use less instances than dispatcher mode, which more cost effective. Since there’s no dispatcher in the system, there is no bottleneck. When we introduced more service instances, in dispatcher mode we have to change something to let the dispatcher know the new instances. But in pulling mode since all service instance are self-managed, there no extra change at all. If there are many incoming messages, since the message bus can queue them in the transportation, service instances would not be crashed. All above are the benefits using the pulling mode, but it will introduce some problem as well. The process tracking and debugging become more difficult. Since the service instances are self-managed, we cannot know which instance will process the message. So we need more information to support debug and track. Real-time response may not be supported. All service instances will process the next message after the current one has done, if we have some real-time request this may not be a good solution. Compare with the Pros and Cons above, the pulling mode would a better solution for the distributed system architecture. Because what we need more is the scalability, cost-effect and the self-management.   WCF and WCF Transport Extensibility Windows Communication Foundation (WCF) is a framework for building service-oriented applications. In the .NET world WCF is the best way to implement the service. In this series I’m going to demonstrate how to implement the pulling mode on top of a message bus by extending the WCF. I don’t want to deep into every related field in WCF but will highlight its transport extensibility. When we implemented an RPC foundation there are many aspects we need to deal with, for example the message encoding, encryption, authentication and message sending and receiving. In WCF, each aspect is represented by a channel. A message will be passed through all necessary channels and finally send to the underlying transportation. And on the other side the message will be received from the transport and though the same channels until the business logic. This mode is called “Channel Stack” in WCF, and the last channel in the channel stack must always be a transport channel, which takes the responsible for sending and receiving the messages. As we are going to implement the WCF over message bus and implement the pulling mode scaling-out solution, we need to create our own transport channel so that the client and service can exchange messages over our bus. Before we deep into the transport channel, let’s have a look on the message exchange patterns that WCF defines. Message exchange pattern (MEP) defines how client and service exchange the messages over the transportation. WCF defines 3 basic MEPs which are datagram, Request-Reply and Duplex. Datagram: Also known as one-way, or fire-forgot mode. The message sent from the client to the service, and no need any reply from the service. The client doesn’t care about the message result at all. Request-Reply: Very common used pattern. The client send the request message to the service and wait until the reply message comes from the service. Duplex: The client sent message to the service, when the service processing the message it can callback to the client. When callback the service would be like a client while the client would be like a service. In WCF, each MEP represent some channels associated. MEP Channels Datagram IInputChannel, IOutputChannel Request-Reply IRequestChannel, IReplyChannel Duplex IDuplexChannel And the channels are created by ChannelListener on the server side, and ChannelFactory on the client side. The ChannelListener and ChannelFactory are created by the TransportBindingElement. The TransportBindingElement is created by the Binding, which can be defined as a new binding or from a custom binding. For more information about the transport channel mode, please refer to the MSDN document. The figure below shows the transport channel objects when using the request-reply MEP. And this is the datagram MEP. And this is the duplex MEP. After investigated the WCF transport architecture, channel mode and MEP, we finally identified what we should do to extend our message bus based transport layer. They are: Binding: (Optional) Defines the channel elements in the channel stack and added our transport binding element at the bottom of the stack. But we can use the build-in CustomBinding as well. TransportBindingElement: Defines which MEP is supported in our transport and create the related ChannelListener and ChannelFactory. This also defines the scheme of the endpoint if using this transport. ChannelListener: Create the server side channel based on the MEP it’s. We can have one ChannelListener to create channels for all supported MEPs, or we can have ChannelListener for each MEP. In this series I will use the second approach. ChannelFactory: Create the client side channel based on the MEP it’s. We can have one ChannelFactory to create channels for all supported MEPs, or we can have ChannelFactory for each MEP. In this series I will use the second approach. Channels: Based on the MEPs we want to support, we need to implement the channels accordingly. For example, if we want our transport support Request-Reply mode we should implement IRequestChannel and IReplyChannel. In this series I will implement all 3 MEPs listed above one by one. Scaffold: In order to make our transport extension works we also need to implement some scaffold stuff. For example we need some classes to send and receive message though out message bus. We also need some codes to read and write the WCF message, etc.. These are not necessary but would be very useful in our example.   Message Bus There is only one thing remained before we can begin to implement our scaling-out support WCF transport, which is the message bus. As I mentioned above, the message bus must have some features to fulfill all the WCF MEPs. In my company we will be using TIBCO EMS, which is an enterprise message bus product. And I have said before we can use any message bus production if it’s satisfied with our requests. Here I would like to introduce an interface to separate the message bus from the WCF. This allows us to implement the bus operations by any kinds bus we are going to use. The interface would be like this. 1: public interface IBus : IDisposable 2: { 3: string SendRequest(string message, bool fromClient, string from, string to = null); 4:  5: void SendReply(string message, bool fromClient, string replyTo); 6:  7: BusMessage Receive(bool fromClient, string replyTo); 8: } There are only three methods for the bus interface. Let me explain one by one. The SendRequest method takes the responsible for sending the request message into the bus. The parameters description are: message: The WCF message content. fromClient: Indicates if this message was came from the client. from: The channel ID that this message was sent from. The channel ID will be generated when any kinds of channel was created, which will be explained in the following articles. to: The channel ID that this message should be received. In Request-Reply and Duplex MEP this is necessary since the reply message must be received by the channel which sent the related request message. The SendReply method takes the responsible for sending the reply message. It’s very similar as the previous one but no “from” parameter. This is because it’s no need to reply a reply message again in any MEPs. The Receive method takes the responsible for waiting for a incoming message, includes the request message and specified reply message. It returned a BusMessage object, which contains some information about the channel information. The code of the BusMessage class is 1: public class BusMessage 2: { 3: public string MessageID { get; private set; } 4: public string From { get; private set; } 5: public string ReplyTo { get; private set; } 6: public string Content { get; private set; } 7:  8: public BusMessage(string messageId, string fromChannelId, string replyToChannelId, string content) 9: { 10: MessageID = messageId; 11: From = fromChannelId; 12: ReplyTo = replyToChannelId; 13: Content = content; 14: } 15: } Now let’s implement a message bus based on the IBus interface. Since I don’t want you to buy and install the TIBCO EMS or any other message bus products, I will implement an in process memory bus. This bus is only for test and sample purpose. It can only be used if the service and client are in the same process. Very straightforward. 1: public class InProcMessageBus : IBus 2: { 3: private readonly ConcurrentDictionary<Guid, InProcMessageEntity> _queue; 4: private readonly object _lock; 5:  6: public InProcMessageBus() 7: { 8: _queue = new ConcurrentDictionary<Guid, InProcMessageEntity>(); 9: _lock = new object(); 10: } 11:  12: public string SendRequest(string message, bool fromClient, string from, string to = null) 13: { 14: var entity = new InProcMessageEntity(message, fromClient, from, to); 15: _queue.TryAdd(entity.ID, entity); 16: return entity.ID.ToString(); 17: } 18:  19: public void SendReply(string message, bool fromClient, string replyTo) 20: { 21: var entity = new InProcMessageEntity(message, fromClient, null, replyTo); 22: _queue.TryAdd(entity.ID, entity); 23: } 24:  25: public BusMessage Receive(bool fromClient, string replyTo) 26: { 27: InProcMessageEntity e = null; 28: while (true) 29: { 30: lock (_lock) 31: { 32: var entity = _queue 33: .Where(kvp => kvp.Value.FromClient == fromClient && (kvp.Value.To == replyTo || string.IsNullOrWhiteSpace(kvp.Value.To))) 34: .FirstOrDefault(); 35: if (entity.Key != Guid.Empty && entity.Value != null) 36: { 37: _queue.TryRemove(entity.Key, out e); 38: } 39: } 40: if (e == null) 41: { 42: Thread.Sleep(100); 43: } 44: else 45: { 46: return new BusMessage(e.ID.ToString(), e.From, e.To, e.Content); 47: } 48: } 49: } 50:  51: public void Dispose() 52: { 53: } 54: } The InProcMessageBus stores the messages in the objects of InProcMessageEntity, which can take some extra information beside the WCF message itself. 1: public class InProcMessageEntity 2: { 3: public Guid ID { get; set; } 4: public string Content { get; set; } 5: public bool FromClient { get; set; } 6: public string From { get; set; } 7: public string To { get; set; } 8:  9: public InProcMessageEntity() 10: : this(string.Empty, false, string.Empty, string.Empty) 11: { 12: } 13:  14: public InProcMessageEntity(string content, bool fromClient, string from, string to) 15: { 16: ID = Guid.NewGuid(); 17: Content = content; 18: FromClient = fromClient; 19: From = from; 20: To = to; 21: } 22: }   Summary OK, now I have all necessary stuff ready. The next step would be implementing our WCF message bus transport extension. In this post I described two scaling-out approaches on the service side especially if we are using the cloud platform: dispatcher mode and pulling mode. And I compared the Pros and Cons of them. Then I introduced the WCF channel stack, channel mode and the transport extension part, and identified what we should do to create our own WCF transport extension, to let our WCF services using pulling mode based on a message bus. And finally I provided some classes that need to be used in the future posts that working against an in process memory message bus, for the demonstration purpose only. In the next post I will begin to implement the transport extension step by step.   Hope this helps, Shaun All documents and related graphics, codes are provided "AS IS" without warranty of any kind. Copyright © Shaun Ziyan Xu. This work is licensed under the Creative Commons License.

    Read the article

  • Windows Update can't install Windows Vista SP1

    - by Harry Johnston
    If you install Windows Vista RTM and run Windows Update, many updates are offered and will successfully install. Once all other updates are installed, Windows Vista service pack 1 is offered. When you attempt to install Windows Vista service pack 1, the service pack installation wizard appears, presenting the license agreement and so on. However, shortly after the installation starts the wizard disappears. Windows Update says that the update was installed successfully. However, service pack 1 is not in fact installed, and will be detected as needed again on the next update check. Repeat ad nauseum. On checking the Windows Update log, error 0x80190194 appears near the beginning of an update check, associated with the URL http://update.microsoft.com/vista/windowsupdate/redir/vistawuredir.cab. Why won't service pack 1 install properly and how do I fix it?

    Read the article

  • dinamically resizing row height in QTreeWidget/QTreeView during edinitg items

    - by serge
    Hi everyone, I have some problems with sizing row's height in QTreeWidget. I use QStyledItemDelegate with QPlainTextEdit. During editing text in QPlainTextEdit i check for changes with a help of: rect = self.blockBoundingRect(self.firstVisibleBlock()) and if text it's height changes i need row in QTreeWidget also resizing. But i don't know how to inform TreeWidget or a Delegate about changes, i even tried to initialize editor with index, that i could use in a future, but it suddenly changes: class MyEditor(QPlainTextEdit): def __init__(self, index = None, parent=None): super(MyEditor, self).__init__(parent) self.index = index self.connect(self, SIGNAL("textChanged()"), self.setHeight) def setHeight(self): if self.index: rect = self.blockBoundingRect(self.firstVisibleBlock()) self.resize(rect.width(), rect.height()) self.emit(SIGNAL("set_height"), QSize(rect.width(), rect.height()), self.index) How can i bound editor's size changes with TreeWidget? And one more thing, by default all items (cells) in TreeWidget have -1 or some big value as default width. I need whole text in cell to be visible, so how can i limit it only by visible range and expand it in height? Thank you in advance, Serge

    Read the article

  • python blocking sockets, send returns immediately

    - by Mark
    Hi, I am writing a multithreaded socket application in Python using the socket module. the server listens for connections and when it gets one it spawns a thread for that socket. the server thread sends some data to the client. but the client is not yet ready to receive it. I thought this would have caused the server to wait until the client starts recv but instead returns immediately the client then calls recv which is blocking and no data is ever received. client socket constructor self.__clientSocket = socket.socket(socket.AF_INET, socket.SOCK_STREAM) self.__clientSocket.connect((server, port)) server socket constructor self.servSock = socket.socket(socket.AF_INET, socket.SOCK_STREAM) self.servSock.setsockopt(socket.SOL_SOCKET, socket.SO_REUSEADDR, 1) #self.servSock.settimeout(None) self.servSock.setblocking(1) self.servSock.bind((self.addr,self.port)) self.servSock.listen(5) listening accept thread try: (cs, address) = self.servSock.accept() except socket.timeout: return threadName = '\r\nClient %s:%s\r\n' % (cs, address) print threadName clientSocketHandler = ClientSocket() clientSocketHandler.setClientSocket(cs) self.clients.newThread(self.clientFunc, {clientSocketHandler : "1"}, threadName).start() server and clients send/rec methods from inside ClientSocket receivedData = self.__clientSocket.recv(1024*1024) self.__clientSocket.send(s) any ideas why send() is returning straight away?

    Read the article

  • python list mysteriously getting set to something within my django/piston handler

    - by Anverc
    To start, I'm very new to python, let alone Django and Piston. Anyway, I've created a new BaseHandler class "class BaseApiHandler(BaseHandler)" so that I can extend some of the stff that BaseHandler does. This has been working fine until I added a new filter that could limit results to the first or last result. Now I can refresh the api page over and over and sometimes it will limit the result even if I don't include /limit/whatever in my URL... I've added some debug info into my return value to see what is happening, and that's when it gets more weird. this return value will make more sense after you see the code, but here they are for reference: When the results are correct: "statusmsg": "2 hours_detail found with query: {'empid':'22','datestamp':'2009-03-02',}", when the results are incorrect (once you read the code you'll notice two things wrong. First, it doesn't have 'limit':'None', secondly it shouldn't even get this far to begin with. "statusmsg": "1 hours_detail found with query: {'empid':'22','datestamp':'2009-03-02',with limit[0,1](limit,None),}", It may be important to note that I'm the only person with access to the server running this right now, so even if it was a cache issue, it doesn't make sense that I can just refresh and get different results by hitting F5 while viewing: http://localhost/api/hours_detail/datestamp/2009-03-02/empid/22 Here's the code broken into urls.py and handlers.py so that you can see what i'm doing: URLS.PY urlpatterns = patterns('', #hours_detail/id/{id}/empid/{empid}/projid/{projid}/datestamp/{datestamp}/daterange/{fromdate}to{todate}/limit/{first|last}/exact #empid is required # id, empid, projid, datestamp, daterange can be in any order url(r'^api/hours_detail/(?:' + \ r'(?:[/]?id/(?P<id>\d+))?' + \ r'(?:[/]?empid/(?P<empid>\d+))?' + \ r'(?:[/]?projid/(?P<projid>\d+))?' + \ r'(?:[/]?datestamp/(?P<datestamp>\d{4,}[-/\.]\d{2,}[-/\.]\d{2,}))?' + \ r'(?:[/]?daterange/(?P<daterange>(?:\d{4,}[-/\.]\d{2,}[-/\.]\d{2,})(?:to|/-)(?:\d{4,}[-/\.]\d{2,}[-/\.]\d{2,})))?' + \ r')+' + \ r'(?:/limit/(?P<limit>(?:first|last)))?' + \ r'(?:/(?P<exact>exact))?$', hours_detail_resource), HANDLERS.PY # inherit from BaseHandler to add the extra functionality i need to process the possibly null URL params class BaseApiHandler(BaseHandler): # keep track of the handler so the data is represented back to me correctly post_name = 'base' # THIS IS THE LIST IN QUESTION - SOMETIMES IT IS GETTING SET TO [0,1] MYSTERIOUSLY # this gets set to a list when the results are to be limited limit = None def has_limit(self): return (isinstance(self.limit, list) and len(self.limit) == 2) def process_kwarg_read(self, key, value, d_post, b_exact): """ this should be overridden in the derived classes to process kwargs """ pass # override 'read' so we can better handle our api's searching capabilities def read(self, request, *args, **kwargs): d_post = {'status':0,'statusmsg':'Nothing Happened'} try: # setup the named response object # select all employees then filter - querysets are lazy in django # the actual query is only done once data is needed, so this may # seem like some memory hog slow beast, but it's actually not. d_post[self.post_name] = self.queryset(request) # this is a string that holds debug information... it's the string I mentioned before pasting this code s_query = '' b_exact = False if 'exact' in kwargs and kwargs['exact'] <> None: b_exact = True s_query = '\'exact\':True,' for key,value in kwargs.iteritems(): # the regex url possibilities will push None into the kwargs dictionary # if not specified, so just continue looping through if that's the case if value == None or key == 'exact': continue # write to the s_query string so we have a nice error message s_query = '%s\'%s\':\'%s\',' % (s_query, key, value) # now process this key/value kwarg self.process_kwarg_read(key=key, value=value, d_post=d_post, b_exact=b_exact) # end of the kwargs for loop else: if self.has_limit(): # THIS SEEMS TO GET HIT SOMETIMES IF YOU CONSTANTLY REFRESH THE API PAGE, EVEN THOUGH # THE LINE IN THE FOR LOOP WHICH UPDATES s_query DOESN'T GET HIS AND THUS self.process_kwarg_read ALSO # DOESN'T GET HIT SO NEITHER DOES limit = [0,1] s_query = '%swith limit[%s,%s](limit,%s),' % (s_query, self.limit[0], self.limit[1], kwargs['limit']) d_post[self.post_name] = d_post[self.post_name][self.limit[0]:self.limit[1]] if d_post[self.post_name].count() == 0: d_post['status'] = 0 d_post['statusmsg'] = '%s not found with query: {%s}' % (self.post_name, s_query) else: d_post['status'] = 1 d_post['statusmsg'] = '%s %s found with query: {%s}' % (d_post[self.post_name].count(), self.post_name, s_query) except: e = sys.exc_info()[1] d_post['status'] = 0 d_post['statusmsg'] = 'error: %s' % e d_post[self.post_name] = [] return d_post class HoursDetailHandler(BaseApiHandler): #allowed_methods = ('GET',) model = HoursDetail exclude = () post_name = 'hours_detail' def process_kwarg_read(self, key, value, d_post, b_exact): if ... # I have several if/elif statements here that check for other things... # 'self.limit =' only shows up in the following elif: elif key == 'limit': order_by = 'clock_time' if value == 'last': order_by = '-clock_time' d_post[self.post_name] = d_post[self.post_name].order_by(order_by) # TO GET HERE, THE ONLY PLACE IN CODE WHERE self.limit IS SET, YOU MUST HAVE GONE THROUGH # THE value == None CHECK???? self.limit = [0, 1] else: raise NameError def read(self, request, *args, **kwargs): # empid is required, so make sure it exists before running BaseApiHandler's read method if not('empid' in kwargs and kwargs['empid'] <> None and kwargs['empid'] >= 0): return {'status':0,'statusmsg':'empid cannot be empty'} else: return BaseApiHandler.read(self, request, *args, **kwargs) Does anyone have a clue how else self.limit might be getting set to [0, 1] ? Am I misunderstanding kwargs or loops or anything in Python?

    Read the article

  • good __eq__, __lt__, ..., __hash__ methods for image class?

    - by Marten Bauer
    I create the following class: class Image(object): def __init__(self, extension, data, urls=None, user_data=None): self._extension = extension self._data = data self._urls = urls self._user_data = user_data self._hex_digest = hashlib.sha1(self._data).hexDigest() Images should be equal when all values are equal. Therefore I wrote: def __eq__(self, other): if isinstance(other, Image) and self.__dict__ == other.__dict__: return True return False def __ne__(self, other): return not self.__eq__(other) def __lt__(self, other): return self.__dict__ < other.__dict__ ... But how should the __hash__ method look like? Equal Images should return equal hashes... def __hash__(self): # won't work !?! return hash(self.__dict__) Is the way I try to use __eq__, __ne__, __lt__, __hash__, ... recommend?

    Read the article

  • Don&rsquo;t Miss &ldquo;Transform Field Service Delivery with Oracle Real-Time Scheduler&rdquo;

    - by ruth.donohue
    Field resources are an expensive element in the service equation. Maximizing the scheduling and routing of these resources is critical in reducing costs, increasing profitability, and improving the customer experience. Oracle Real-Time Scheduler creates cost-optimized plans and schedules for service technicians that increase operational efficiencies and improve margins. It enhances Oracle’s Siebel Field Service with real-time scheduling and dispatch capabilities that ensure service requests are allocated efficiently and service levels are honored. Join our live Webcast to learn how your organization can leverage Oracle Real-Time Scheduler to: Increase operational efficiency with real-time scheduling that enables field service technicians to handle more calls per day and reduce travel mileage Resolve issues faster with dynamic work flows that ensure you have the right technician with the right skill set for the right job Improve the customer experience with real-time planning that optimizes field technician routing, reduces customer wait times, and minimizes missed SLAs Date: Thursday, March 10, 2011 Time: 8:30 am PT / 11:30 am ET / 4:30 pm UK / 5:30 pm CET Click here to register now.   Technorati Tags: Siebel Field Service,Oracle Real-Time Scheduler

    Read the article

  • assembling an object graph without an ORM -- in the service layer or data layer?

    - by Hans Gruber
    At my current gig, our persistence layer uses IBatis going against SQL Server stored procedures (puke). IMHO, this approach has many disadvantages over the use of a "true" ORM such NHibernate or EF, but the one I'm trying to address here revolves around all the boilerplate code needed to map data from a result set into an object graph. Say I have the following DTO object graph I want to return to my presentation layer: IEnumerable<CustomerDTO> |--> IEnumerable<AddressDTO> |--> LatestOrderDTO The way I've implemented this is to have a discrete method in my DAO class to return each IEnumerable<*DTO>, and then have my service class be responsible for orchestrating the calls to the DAO. It then returns the fully assembled object graph to the client: public class SomeService(){ public SomeService(IDao someDao){ this._someDao = someDao; } public IEnumerable<CustomerDTO> ListCustomersForHistory(int brokerId){ var customers = _someDao.ListCustomersForBroker(brokerId); foreach (customer in customers){ customer.Addresses = someDao.ListCustomersAddresses(brokerId); customer.LatestOrder = someDao.GetCustomerLatestOrder(brokerId); } } return customers; } My question is should this logic belong in the service layer or the should I make my DAO such that it instead returns the assembled object graph. If I was using NHibernate, I assume that this kind of relationship association between objects comes for "free"?

    Read the article

  • New to JEE; architecture suggestions for a service/daemon?

    - by Kate
    I am brand new to the JEE world. As an exercise to try and familiarize myself with JEE, I'm trying to create a tiered web-app, but I'm getting a little stuck on what the best way is to spin up a service in the background that does work. Parameters of the service: It must open and hold a socket connection and receive information from the connected server. There is a 1-to-1 correlation between a user and a new socket connection. So the idea is the user presses a button on the web-page, and somewhere on the server a socket connection is opened. For the remainder of the users session (or until the user presses some sort of disconnect button) the socket remains open and pushes received information to some sort of centralized store that servlets can query and return to the user via AJAX. Is there a JEE type way to handle this situation? Naturally what I would think to do is to just write a Java application that listens on a port that the servlets can connect to and spawns new threads that open these sockets, but that seems very ad-hoc to me. (PS: I am also new to Stack Overflow, so forgive me if it takes me some time to figure the site out!)

    Read the article

  • New to J2EE; architecture suggestions for a service/daemon?

    - by Kate
    I am brand new to the J2EE world. As an exercise to try and familiarize myself with J2EE, I'm trying to create a tiered web-app, but I'm getting a little stuck on what the best way is to spin up a service in the background that does work. Paramters of the service: It must open and hold a socket connection and receive information from the connected server. There is a 1-to-1 correlation between a user and a new socket connection. So the idea is the user presses a button on the web-page, and somewhere on the server a socket connection is opened. For the remainder of the users session (or until the user presses some sort of disconnect button) the socket remains open and pushes received information to some sort of centralized store that servlets can query and return to the user via AJAX. Is there a J2EE type way to handle this situation? Naturally what I would think to do is to just write a Java application that listens on a port that the servlets can connect to and spawns new threads that open these sockets, but that seems very ad-hoc to me. (PS: I am also new to Stack Overflow, so forgive me if it takes me some time to figure the site out!)

    Read the article

  • i don't receive mail notification...Nagios Core 4

    - by alessio
    I have a problem with automatically mail notification in Nagios Core 4 installed on ubuntu 12 .04 lts server... i have tried to send mail with nagios user and root user with the command: echo "test" | mail -s "test mail" [email protected] and i received mail correctly... but i don't receive any automatically mail notification... i don't know how can i do to resolve this issue! :( these are my configuration files (commands.cfg, contacts.cfg, nagios.log, mail.log): commands.cfg (the path /usr/bin/mail is the right path): # 'notify-host-by-email' command definition define command{ command_name notify-host-by-email command_line /usr/bin/printf "%b" "***** Nagios *****\n\nNotification Type: $NOTIFICATIONTYPE$\nHost: $HOSTNAME$\nState: $HOSTSTATE$\nAddress: $HOSTADDRESS$\nInfo: $HOSTOUTPUT$\n\nDate/Time: $LONGDATETIME$\n" | /usr/bin/mail -s "** $NOTIFICATIONTYPE$ Host Alert: $HOSTNAME$ is $HOSTSTATE$ **" $CONTACTEMAIL$ } # 'notify-service-by-email' command definition define command{ command_name notify-service-by-email command_line /usr/bin/printf "%b" "***** Nagios *****\n\nNotification Type: $NOTIFICATIONTYPE$\n\nService: $SERVICEDESC$\nHost: $HOSTALIAS$\nAddress: $HOSTADDRESS$\nState: $SERVICESTATE$\n\nDate/Time: $LONGDATETIME$\n\nAdditional Info:\n\n$SERVICEOUTPUT$\n" | /usr/bin/mail -s "** $NOTIFICATIONTYPE$ Service Alert: $HOSTALIAS$/$SERVICEDESC$ is $SERVICESTATE$ **" $CONTACTEMAIL$ } # 'process-host-perfdata' command definition define command{ command_name process-host-perfdata command_line /usr/bin/printf "%b" "$LASTHOSTCHECK$\t$HOSTNAME$\t$HOSTSTATE$\t$HOSTATTEMPT$\t$HOSTSTATETYPE$\t$HOSTEXECUTIONTIME$\t$HOSTOUTPUT$\t$HOSTPERFDATA$\n" >> /usr/local/nagios/var/host-perfdata.out } # 'process-service-perfdata' command definition define command{ command_name process-service-perfdata command_line /usr/bin/printf "%b" "$LASTSERVICECHECK$\t$HOSTNAME$\t$SERVICEDESC$\t$SERVICESTATE$\t$SERVICEATTEMPT$\t$SERVICESTATETYPE$\t$SERVICEEXECUTIONTIME$\t$SERVICELATENCY$\t$SERVICEOUTPUT$\t$SERVICEPERFDATA$\n" >> /usr/local/nagios/var/service-perfdata.out } contacts.cfg: define contact{ contact_name supporto alias Supporto Clienti DEA service_notification_period 24x7 host_notification_period 24x7 service_notification_options w,u,c,r host_notification_options d,r service_notification_commands notify-service-by-email host_notification_commands notify-host-by-email email [email protected] } define contactgroup{ contactgroup_name admins alias Nagios Administrators members supporto } nagios.log: [1401871412] SERVICE ALERT: fileserver;Current Users;OK;SOFT;2;USERS OK - 1 users currently logged in [1401871953] SERVICE ALERT: backups;Nagios Status;WARNING;SOFT;1;NAGIOS WARNING: 36 processes, status log updated 541 seconds ago [1401872133] SERVICE ALERT: backups;Nagios Status;OK;SOFT;2;NAGIOS OK: 36 processes, status log updated 180 seconds ago [1401872321] SERVICE ALERT: posta;Swap Usage;CRITICAL;SOFT;1;CRITICAL - Plugin timed out after 10 seconds [1401872322] SERVICE ALERT: fileserver;Current Users;CRITICAL;SOFT;1;CRITICAL - Plugin timed out after 10 seconds [1401872420] SERVICE ALERT: archivio;Disk Space;CRITICAL;SOFT;1;CRITICAL - Plugin timed out after 10 seconds [1401872492] SERVICE ALERT: fileserver;Current Users;OK;SOFT;2;USERS OK - 1 users currently logged in [1401872492] SERVICE ALERT: posta;Swap Usage;OK;SOFT;2;SWAP OK: 100% free (1984 MB out of 1984 MB) [1401872590] SERVICE ALERT: archivio;Disk Space;OK;SOFT;2;DISK OK [1401872931] Auto-save of retention data completed successfully. [1401873333] SERVICE ALERT: backups;Nagios Status;WARNING;SOFT;1;NAGIOS WARNING: 36 processes, status log updated 402 seconds ago [1401873513] SERVICE ALERT: backups;Nagios Status;OK;SOFT;2;NAGIOS OK: 36 processes, status log updated 180 seconds ago mail.log (i think that the problem is here but i don't know how to resolve it): Jun 4 10:00:01 backups sm-msp-queue[6109]: My unqualified host name (backups) unknown; sleeping for retry Jun 4 10:01:01 backups sm-msp-queue[6109]: unable to qualify my own domain name (backups) -- using short name Jun 4 10:20:01 backups sm-msp-queue[7247]: My unqualified host name (backups) unknown; sleeping for retry Jun 4 10:21:01 backups sm-msp-queue[7247]: unable to qualify my own domain name (backups) -- using short name Jun 4 10:40:01 backups sm-msp-queue[8327]: My unqualified host name (backups) unknown; sleeping for retry Jun 4 10:41:01 backups sm-msp-queue[8327]: unable to qualify my own domain name (backups) -- using short name Jun 4 11:00:01 backups sm-msp-queue[9549]: My unqualified host name (backups) unknown; sleeping for retry Jun 4 11:01:01 backups sm-msp-queue[9549]: unable to qualify my own domain name (backups) -- using short name Jun 4 11:20:01 backups sm-msp-queue[10678]: My unqualified host name (backups) unknown; sleeping for retry Jun 4 11:21:01 backups sm-msp-queue[10678]: unable to qualify my own domain name (backups) -- using short name i'm at the last step and i want to finish this Nagios Core! :) Any help be appreciate!:) host definition (this host have the disk almost full and it is in hard state but non notification) : define host{ use generic-host ; Name of host template to use host_name posta alias Server Posta ESA address 10.10.2.102 parents xen1, xen2 icon_image redhat.png statusmap_image redhat.gd2 } service definition: define service{ use generic-service host_name xen1, maestro, xen2, posta, nas002, serv2, esasrvmi02, esaubuntumi service_description Disk Space check_command ssh_all_disks!10%!5% } Notification is allowed for the contact definition you gave, but is it also allowed at the the service level ? sorry but i don't understand this thing! :(

    Read the article

  • Nokogiri pull parser (Nokogiri::XML::Reader) issue with self closing tag

    - by Vlad Zloteanu
    I have a huge XML(400MB) containing products. Using a DOM parser is therefore excluded, so i tried to parse and process it using a pull parser. Below is a snippet from the each_product(&block) method where i iterate over the product list. Basically, using a stack, i transform each <product> ... </product> node into a hash and process it. while (reader.read) case reader.node_type #start element when Nokogiri::XML::Node::ELEMENT_NODE elem_name = reader.name.to_s stack.push([elem_name, {}]) #text element when Nokogiri::XML::Node::TEXT_NODE, Nokogiri::XML::Node::CDATA_SECTION_NODE stack.last[1] = reader.value #end element when Nokogiri::XML::Node::ELEMENT_DECL return if stack.empty? elem = stack.pop parent = stack.last if parent.nil? yield(elem[1]) elem = nil next end key = elem[0] parent_childs = parent[1] # ... parent_childs[key] = elem[1] end The issue is on self-closing tags (EG <country/>), as i can not make the difference between a 'normal' and a 'self-closing' tag. They both are of type Nokogiri::XML::Node::ELEMENT_NODE and i am not able to find any other discriminator in the documentation. Any ideas on how to solve this issue?

    Read the article

  • Self - hosted WCF server and SSL

    - by jitm
    Hello, There is self - hosted WCF server (Not IIS), and was generated certificates (on the Win Xp) using command line like makecert.exe -sr CurrentUser -ss My -a sha1 -n CN=SecureClient -sky exchange -pe makecert.exe -sr CurrentUser -ss My -a sha1 -n CN=SecureServer -sky exchange -pe These certificates was added to the server code like this: serviceCred.ServiceCertificate.SetCertificate(StoreLocation.LocalMachine, StoreName.My, X509FindType.FindBySubjectName, "SecureServer"); serviceCred.ClientCertificate.SetCertificate(StoreLocation.LocalMachine, StoreName.My, X509FindType.FindBySubjectName, "SecureClient"); After all previous operation I created simple client to check SSL connection to the server. Client configuration: <?xml version="1.0" encoding="utf-8" ?> <configuration> <system.serviceModel> <bindings> <basicHttpBinding> <binding name="BasicHttpBinding_IAdminContract" closeTimeout="00:01:00" openTimeout="00:01:00" receiveTimeout="00:10:00" sendTimeout="00:01:00" allowCookies="false" bypassProxyOnLocal="false" hostNameComparisonMode="StrongWildcard" maxBufferSize="65536" maxBufferPoolSize="524288" maxReceivedMessageSize="65536" messageEncoding="Text" textEncoding="utf-8" transferMode="Buffered" useDefaultWebProxy="true"> <readerQuotas maxDepth="32" maxStringContentLength="8192" maxArrayLength="16384" maxBytesPerRead="4096" maxNameTableCharCount="16384" /> <security mode="TransportCredentialOnly"> <transport clientCredentialType="Basic"/> </security> </binding> </basicHttpBinding> </bindings> <client> <endpoint address="https://myhost:8002/Admin" binding="basicHttpBinding" bindingConfiguration="BasicHttpBinding_IAdminContract" contract="Admin.IAdminContract" name="BasicHttpBinding_IAdminContract" /> </client> </system.serviceModel> </configuration> Code: Admin.AdminContractClient client = new AdminContractClient("BasicHttpBinding_IAdminContract"); client.ClientCredentials.UserName.UserName = "user"; client.ClientCredentials.UserName.Password = "pass"; var result = client.ExecuteMethod() During execution I receiving next error: The provided URI scheme 'https' is invalid; expected 'http'.\r\nParameter name: via Question: How to enable ssl for self-hosted server and where should I set - up certificates for client and server ? Thanks.

    Read the article

  • Applying for .net jobs as a "self learner"

    - by DeanMc
    Hi All, I have recently started applying for .Net jobs. I currently work in a sales role with a large telco. I found out quite late that I like programming and as such bought my house and made commitments that mean college is not an option. What I would like to know is, is it harder to get a junior job as a self learner? I have gotten a few enquiries regarding my C.V but nothing concrete yet. I try to be involved in projects as I get the chance and tend to put up any worthwhile projects as I develop them. Some examples of my work are: A Xaml lexer and parser: http://www.xlight.mendhak.com A font obfuscation tool: http://www.silverlightforums.com/showthread.php?1516-Font-Obsfucation-Tool-ALPHA A tagger for m4a: http://projectaudiophile.codeplex.com/SourceControl/list/changesets I, of course think that these are great examples of my work but that is my opinion based on self learning. The other query is how much should I actually know? I've never used linked lists but I know that strings are immutable and I understand what that means. I am only touching on T-SQL but I understand things like how properties function in IL (as two standard methods :) ). I suppose I understand a lot of concepts but specific features need some looking up to implement as I may not know the syntax off the top of my head.

    Read the article

  • Django Template For Loop Removing <img> Self-Closing

    - by Zack
    Django's for loop seems to be removing all of my <img> tag's self-closing...ness (/>). In the Template, I have this code: {% for item in item_list %} <li> <a class="left" href="{{ item.url }}">{{ item.name }}</a> <a class="right" href="{{ item.url }}"> <img src="{{ item.icon.url }}" alt="{{ item.name }} Logo." /> </a> </li> {% endfor %} It outputs this: <li> <a class="left" href="/some-url/">This is an item</a> <a class="right" href="/some-url/"> <img src="/media/img/some-item.jpg" alt="This is an item Logo."> </a> </li> As you can see, the <img> tag is no longer closed, and thus the page doesn't validate. This isn't a huge issue since it'll still render properly in all browsers, but I'd like to know how to solve it. I've tried wrapping the whole for loop in {% autoescape off %}...{% endautoescape %} but that didn't change anything. All other self-closed <img> tags in the document outside the for loop still properly close.

    Read the article

  • Entity framework self referencing loop detected

    - by Lyd0n
    I have a strange error. I'm experimenting with a .NET 4.5 Web API, Entity Framework and MS SQL Server. I've already created the database and set up the correct primary and foreign keys and relationships. I've created a .edmx model and imported two tables: Employee and Department. A department can have many employees and this relationship exists. I created a new controller called EmployeeController using the scaffolding options to create an API controller with read/write actions using Entity Framework. In the wizard, selected Employee as the model and the correct entity for the data context. The method that is created looks like this: // GET api/Employee public IEnumerable<Employee> GetEmployees() { var employees = db.Employees.Include(e => e.Department); return employees.AsEnumerable(); } When I call my API via /api/Employee, I get this error: ...The 'ObjectContent`1' type failed to serialize the response body for content type 'application/json; ...System.InvalidOperationException","StackTrace":null,"InnerException":{"Message":"An error has occurred.","ExceptionMessage":"Self referencing loop detected with type 'System.Data.Entity.DynamicProxies.Employee_5D80AD978BC68A1D8BD675852F94E8B550F4CB150ADB8649E8998B7F95422552'. Path '[0].Department.Employees'.","ExceptionType":"Newtonsoft.Json.JsonSerializationException","StackTrace":" ... Why is it self referencing [0].Department.Employees? That doesn't make a whole lot of sense. I would expect this to happen if I had circular referencing in my database but this is a very simple example. What could be going wrong?

    Read the article