  • Why is cpu power management not working in Server 2012 with Hyper-V?

    - by Roland
    We've been using Server2008R2 with Hyper-V for a couple of years now and chose it at the time because of its ability to make use of Intel SpeedStep and AMD PowerNow! Now with Server 2012 and Hyper-V V3, all power management abilities seem to be gone. The CPUs are always at full speed and our servers need twice the energy as before while idling. (Yes, the CPU P-states are enabled in the BIOS) Is this by design? Is there a workaround to enable cpu power management again? Despite the great new features of Hyper-V 3, this would be a show-stopper for us since we are very concerned about energy consumption.

    Read the article

  • Is it really necessary to call /bin/sync twice before an unmanaged power-off?

    - by Jeremy Friesner
    Hi all, My company sells an "embedded device" which is implemented as a headless Linux box with ext4 on an internal SSD. Some of our users have a habit of doing a "save current settings" on this box, and then cutting power to the unit as soon as the unit reports that the save completed (ie two seconds later). This was causing occasional corruption of the saved files, as the data wouldn't always get flushed to the SSD before the power went out. So I tweaked my software to run /bin/sync immediately after writing the file (after closing the file handle but before notifying the user that the save completed). This appears to fix the issue, but my coworker says that one call to /bin/sync isn't sufficient, and that to be really safe I ought to run /bin/sync twice in a row. That sounds like paranoia to me... Perhaps a habit from earlier versions of Linux or unix whose sync utility didn't work reliably. Does his advice have merit, or should one call to /bin/sync suffice?

    Read the article

  • Does Wake-on-LAN from power state S5 require any OS configuration?

    - by TARehman
    I am configuring a HTPC which I would like to be able to power on using Wake-on-LAN, from the S5 state (full shutdown, still plugged in). The system is running Linux Mint 14 Cinnamon. I'm getting some conflicting information in my searching on the Net. I am not concerned with using WoL to change the state from standby or hibernate to on. Because of the current interface to our TV, the system must be either turned on or turned off. So, basically, this system will cycle from S0 to S5, and from S5 back to S0, and so on. Some tutorials suggest that I need to use ethtool to configure things after enabling WoL in my BIOS, but my understanding is that doing an S5 - S0 power on only requires the BIOS to be configured (since when the computer is in state S5, the OS hasn't even been loaded anyway). Can I use WoL with only the BIOS configured to go from state S5 to S0, or will I need to configure the OS as well?

    Read the article

  • Can I run my MacBook in clamshell mode without being connected to power?

    - by kch
    Hi, At home, I run my MacBook in clamshell mode (closed lid, external display). This works fine when you're connected to the power adapter, but it doesn't work when running on battery. That's how it's supposed to be and Apple has some kb entry on the issue. But it's also lame. You can prevent the machine from sleeping when closed by running InsomniaX, but then it'll assume the builtin display is still active, so you end up with a two-display setup when you really only want the external. This is obviously less than ideal. So, is there any work around, hack, utility, black magic that I can use to make it run in clamshell mode while strictly on battery power? Also, bonus points for a solution that makes the AC status not affect the machine state at all. (Like, you know, it does normally, when not in clamshell.)

    Read the article

  • How do I make a partition usable in windows 7 after power loss?

    - by user1306322
    A few days ago I was installing some software and power went down. When I rebooted, the partition to which the software was installed was not accessible. Disk manager shows that it's there, but doesn't show type, if it's healthy and gives me an error when trying to read its properties. The problem seems to be common after power loss, people recommend solving it by assigning a letter to the partition via DiskPart utility, but partition isn't listed in my case. I can access that partition with bootable OSs (like bootable Ubuntu or winXP) and all the files are there, but another installation of Windows 7 gives me the same results as the original. I could just copy all data to another disk if there was enough space, but unfortunately the size of partition I'm having problems with is 1.1TB. How do I regain access to the partition in my original Windows 7 installation without losing any data?

    Read the article

  • Computer only booting after POWER ON/OFF 10 times or more?

    - by Jan Gressmann
    Hi fellow geeks, recently my computer started to behave like an old car and won't start up anymore unless I flip the power switch repeatedly. What happens when I power it on: CPU fans spins briefly and very slowly, then it stops Same with GPU fan No BIOS beeps or HDD activity Screen stays black After turning it on and off for like 10 times, it'll eventually boot like normal and run smooth without any problems what-so-ever. But I'm worried it might eventually die completely. Anyone know the most common cause of this? Maybe I should just leave the computer powered on? :)

    Read the article

  • Find all A^x in a given range

    - by Austin Henley
    I need to find all monomials in the form AX that when evaluated falls within a range from m to n. It is safe to say that the base A is greater than 1, the power X is greater than 2, and only integers need to be used. For example, in the range 50 to 100, the solutions would be: 2^6 3^4 4^3 My first attempt to solve this was to brute force all combinations of A and X that make "sense." However this becomes too slow when used for very large numbers in a big range since these solutions are used in part of much more intensive processing. Here is the code: def monoSearch(min, max): base = 2 power = 3 while 1: while base**power < max: if base**power > min: print "Found " + repr(base) + "^" + repr(power) + " = " + repr(base**power) power = power + 1 base = base + 1 power = 3 if base**power > max: break I could remove one base**power by saving the value in a temporary variable but I don't think that would make a drastic effect. I also wondered if using logarithms would be better or if there was a closed form expression for this. I am open to any optimizations or alternatives to finding the solutions.

    Read the article

  • Does generation of debug information to JSP classes add much to javac execution time?

    - by Rich
    Hi I am looking looking into the options for tweaking the performance of JBoss 5.1.0 and one of the options available to me is to disable the generation of debug information when compiling JSPs. I know that the presence/absence of debug information for the JVM makes no real difference, but does the generation of that debug information add much to compile time? Thanks in advance Richard

    Read the article

  • Open XML SDK 2.0 - Split table to new power point slide when content flows off current slide

    - by amurra
    I have a bunch of data that I need to export from a website to a power point presentation and have been using Open XML SDK 2.0 to perform this task. I have a power point presentation that I am putting through Open XML SDK 2.0 Productivity Tool to generate the template code that I can use to recreate the export. On one of those slides I have a table and the requirement is to add data to that table and break that table across multiple slides if the table exceeds the bottom of the slide. The approach I have taken is to determine the height of the table and if it exceeds the height of the slide, move that new content into the next slide. I have read Bryan and Jones blog on adding repeating data to a power point slide, but my scenario is a little different. They use the following code: A.Table tbl = current.Slide.Descendants<A.Table>().First(); A.TableRow tr = new A.TableRow(); tr.Height = heightInEmu; tr.Append(CreateDrawingCell(imageRel + imageRelId)); tr.Append(CreateTextCell(category)); tr.Append(CreateTextCell(subcategory)); tr.Append(CreateTextCell(model)); tr.Append(CreateTextCell(price.ToString())); tbl.Append(tr); imageRelId++; This won't work for me since they know what height to set the table row to since it will be the height of the image, but when adding in different amounts of text I do not know the height ahead of time so I just set tr.Heightto a default value. Here is my attempt at figuring at the table height: A.Table tbl = tableSlide.Slide.Descendants<A.Table>().First(); A.TableRow tr = new A.TableRow(); tr.Height = 370840L; tr.Append(PowerPointUtilities.CreateTextCell("This"); tr.Append(PowerPointUtilities.CreateTextCell("is")); tr.Append(PowerPointUtilities.CreateTextCell("a")); tr.Append(PowerPointUtilities.CreateTextCell("test")); tr.Append(PowerPointUtilities.CreateTextCell("Test")); tbl.Append(tr); tableSlide.Slide.Save(); long tableHeight = PowerPointUtilities.TableHeight(tbl); Here are the helper methods: public static A.TableCell CreateTextCell(string text) { A.TableCell tableCell = new A.TableCell( new A.TextBody(new A.BodyProperties(), new A.Paragraph(new A.Run(new A.Text(text)))), new A.TableCellProperties()); return tableCell; } public static Int64Value TableHeight(A.Table table) { long height = 0; foreach (var row in table.Descendants<A.TableRow>() .Where(h => h.Height.HasValue)) { height += row.Height.Value; } return height; } This correctly adds the new table row to the existing table, but when I try and get the height of the table, it returns the original height and not the new height. The new height meaning the default height I initially set and not the height after a large amount of text has been inserted. It seems the height only gets readjusted when it is opened in power point. I have also tried accessing the height of the largest table cell in the row, but can't seem to find the right property to perform that task. My question is how do you determine the height of a dynamically added table row since it doesn't seem to update the height of the row until it is opened in power point? Any other ways to determine when to split content to another slide while using Open XML SDK 2.0? I'm open to any suggestion on a better approach someone might have taken since there isn't much documentation on this subject.

    Read the article

  • ServiceRoute + WebServiceHostFactory kills WSDL generation? How to create extensionless WCF service

    - by Ethan J. Brown
    I'm trying to use extenionless / .svc-less WCF services. Can anyone else confirm or deny the issue I'm experiencing? I use routing in code, and do this in Application_Start of global.asax.cs: RouteTable.Routes.Add(new ServiceRoute("Data", new WebServiceHostFactory(), typeof(DataDips))); I have tested in both IIS 6 and IIS 7.5 and I can use the service just fine (ie my extensionless handler is correctly configured for ASP.NET). However, metadata generation is totally screwed up. I can hit my /mex endpoint with the WCF Test Client (and I presume svcutil.exe) -- but the ?wsdl generation you typically get with .svc is toast. I can't hit it with a browser (get 400 bad request), I can't hit it with wsdl.exe, etc. Metadata generation is configured correctly in web.config. This is a problem of course, because the service is exposed as basicHttpBinding so that an old style ASMX client can get to it. But of course, the client can't generate the proxy without a WSDL description. If I instead use serviceActivation routing in config like this, rather than registering a route in code: <serviceHostingEnvironment aspNetCompatibilityEnabled="true"> <serviceActivations> <add relativeAddress="Data.svc" service="DataDips" /> </serviceActivations> </serviceHostingEnvironment> Then voila... it works. But then I don't have a clean extensionless url. If I change relativeAddress from Data.svc to Data, then I get a configuration exception as this is not supported by config. (Must use an extension registered to WCF). I've also attempted to use this code in conjunction with the above config: RouteTable.Routes.MapPageRoute("","Data/{*data}","~/Data.svc/{*data}",false); My thinking is that I can just point the extensionless url at the configured .svc url. This doesn't work -- the /Data.svc continues to work, but /Data returns a 404. Anyone with any bright ideas?

    Read the article

  • Help me understand why page sizes are a power of 2?

    - by eric
    Answer I need help with is: Recall that paging is implemented by breaking up an address into a page and offset number. It is most efficient to break the address into X page bits and Y offset bits, rather than perform arithmetic on the address to calculate the page number and offset. Because each bit position represents a power of 2, splitting an address between bits results in a page size that is a power of 2. i don't quite understand this answer, can anyone give a simpler explanation?

    Read the article

  • Toshiba Qosmio: Battery Stuck at 60%, does not Charges, PC can't power up, can't remain on with out

    - by Fellknight
    Just like the tittle says, now let me try to give some more detail about the symptoms; The battery is stuck at 60 percent (68% at the moment of this writing).When hovering over the battery icon in Windows 7 Home Premium x64 it reads:"68% available (plugged in, charging)", there's no x or any sing the OS is displaying any error. No matter how much time left connected to the AC adapter the battery doesn't charge, it seems however it continues to discharge at its normal rate when disconnected from the laptop (about 1% each 2 weeks). Now this last symptom is the one i find most strange it "seems" the laptop somehow isn't recognizing the battery because even with the remaining charge of 60%(ish) the laptop wont power up or remain on if disconnected from its AC adapter(if it's on and is unplugged it will immediately turn off). Meaning that even with the battery attached correctly in its right place is as if running the laptop with no battery at all. Toshiba's Utilities haven't detected anything strange (or anything for that matter) with the battery or the hardware. The laptop when in use is connected 90% of the time to a Belkin surge protector (like my 1TB EHD). The protector is working correctly (green light on) and the 1TB HD too, thus a power surge having damaged it's very unlikely. Thnx in advance

    Read the article

  • Best way to 'harden' embedded ext4 file server against unexpected loss of power?

    - by Jeremy Friesner
    Hi all, First, a little background: my company makes an audio streaming device that is a headless, rack-mounted Linux box with a couple of SSDs attached. Each SSD is formatted with ext4. The users can connect to the system using Samba/CIFS to upload new audio files or access existing ones. There is also custom software for streaming out audio over the network. This is all fine. The only problem is that the users are audio people, not computer people, and see the system as a 'black box', not as a computer. Which means that at the end of the day, they aren't going to ssh in to the box and enter "/sbin/shutdown -h"; they are just going to cut power to the rack and leave, and expect things to still work properly the next day. Since ext4 has journalling, journal checksumming, etc, this mostly works. The only time it doesn't work is when someone uploads a new file via Samba and then cuts power to the system before the uploaded data has been fully flushed to the disk. In that case, they come in the next day and find that their new file has been truncated or is missing entirely, and are unhappy. My question is, what is the best way to avoid this problem? Is there a way to get smbd to call "sync" at the end of every upload? (Performance on uploads isn't so important, since they only happen occasionally). Or is there a way to tell ext4 to automatically flush within a few seconds of any change to a file? (Again, performance can be sacrificed for safety here) Should I set a particular write-ordering mode, activate barriers, etc?

    Read the article

  • The Benefits of Smart Grid Business Software

    - by Sylvie MacKenzie, PMP
    Smart Grid Background What Are Smart Grids?Smart Grids use computer hardware and software, sensors, controls, and telecommunications equipment and services to: Link customers to information that helps them manage consumption and use electricity wisely. Enable customers to respond to utility notices in ways that help minimize the duration of overloads, bottlenecks, and outages. Provide utilities with information that helps them improve performance and control costs. What Is Driving Smart Grid Development? Environmental ImpactSmart Grid development is picking up speed because of the widespread interest in reducing the negative impact that energy use has on the environment. Smart Grids use technology to drive efficiencies in transmission, distribution, and consumption. As a result, utilities can serve customers’ power needs with fewer generating plants, fewer transmission and distribution assets,and lower overall generation. With the possible exception of wind farm sprawl, landscape preservation is one obvious benefit. And because most generation today results in greenhouse gas emissions, Smart Grids reduce air pollution and the potential for global climate change.Smart Grids also more easily accommodate the technical difficulties of integrating intermittent renewable resources like wind and solar into the grid, providing further greenhouse gas reductions. CostsThe ability to defer the cost of plant and grid expansion is a major benefit to both utilities and customers. Utilities do not need to use as many internal resources for traditional infrastructure project planning and management. Large T&D infrastructure expansion costs are not passed on to customers.Smart Grids will not eliminate capital expansion, of course. Transmission corridors to connect renewable generation with customers will require major near-term expenditures. Additionally, in the future, electricity to satisfy the needs of population growth and additional applications will exceed the capacity reductions available through the Smart Grid. At that point, expansion will resume—but with greater overall T&D efficiency based on demand response, load control, and many other Smart Grid technologies and business processes. Energy efficiency is a second area of Smart Grid cost saving of particular relevance to customers. The timely and detailed information Smart Grids provide encourages customers to limit waste, adopt energy-efficient building codes and standards, and invest in energy efficient appliances. Efficiency may or may not lower customer bills because customer efficiency savings may be offset by higher costs in generation fuels or carbon taxes. It is clear, however, that bills will be lower with efficiency than without it. Utility Operations Smart Grids can serve as the central focus of utility initiatives to improve business processes. Many utilities have long “wish lists” of projects and applications they would like to fund in order to improve customer service or ease staff’s burden of repetitious work, but they have difficulty cost-justifying the changes, especially in the short term. Adding Smart Grid benefits to the cost/benefit analysis frequently tips the scales in favor of the change and can also significantly reduce payback periods.Mobile workforce applications and asset management applications work together to deploy assets and then to maintain, repair, and replace them. Many additional benefits result—for instance, increased productivity and fuel savings from better routing. Similarly, customer portals that provide customers with near-real-time information can also encourage online payments, thus lowering billing costs. Utilities can and should include these cost and service improvements in the list of Smart Grid benefits. What Is Smart Grid Business Software? Smart Grid business software gathers data from a Smart Grid and uses it improve a utility’s business processes. Smart Grid business software also helps utilities provide relevant information to customers who can then use it to reduce their own consumption and improve their environmental profiles. Smart Grid Business Software Minimizes the Impact of Peak Demand Utilities must size their assets to accommodate their highest peak demand. The higher the peak rises above base demand: The more assets a utility must build that are used only for brief periods—an inefficient use of capital. The higher the utility’s risk profile rises given the uncertainties surrounding the time needed for permitting, building, and recouping costs. The higher the costs for utilities to purchase supply, because generators can charge more for contracts and spot supply during high-demand periods. Smart Grids enable a variety of programs that reduce peak demand, including: Time-of-use pricing and critical peak pricing—programs that charge customers more when they consume electricity during peak periods. Pilot projects indicate that these programs are successful in flattening peaks, thus ensuring better use of existing T&D and generation assets. Direct load control, which lets utilities reduce or eliminate electricity flow to customer equipment (such as air conditioners). Contracts govern the terms and conditions of these turn-offs. Indirect load control, which signals customers to reduce the use of on-premises equipment for contractually agreed-on time periods. Smart Grid business software enables utilities to impose penalties on customers who do not comply with their contracts. Smart Grids also help utilities manage peaks with existing assets by enabling: Real-time asset monitoring and control. In this application, advanced sensors safely enable dynamic capacity load limits, ensuring that all grid assets can be used to their maximum capacity during peak demand periods. Real-time asset monitoring and control applications also detect the location of excessive losses and pinpoint need for mitigation and asset replacements. As a result, utilities reduce outage risk and guard against excess capacity or “over-build”. Better peak demand analysis. As a result: Distribution planners can better size equipment (e.g. transformers) to avoid over-building. Operations engineers can identify and resolve bottlenecks and other inefficiencies that may cause or exacerbate peaks. As above, the result is a reduction in the tendency to over-build. Supply managers can more closely match procurement with delivery. As a result, they can fine-tune supply portfolios, reducing the tendency to over-contract for peak supply and reducing the need to resort to spot market purchases during high peaks. Smart Grids can help lower the cost of remaining peaks by: Standardizing interconnections for new distributed resources (such as electricity storage devices). Placing the interconnections where needed to support anticipated grid congestion. Smart Grid Business Software Lowers the Cost of Field Services By processing Smart Grid data through their business software, utilities can reduce such field costs as: Vegetation management. Smart Grids can pinpoint momentary interruptions and tree-caused outages. Spatial mash-up tools leverage GIS models of tree growth for targeted vegetation management. This reduces the cost of unnecessary tree trimming. Service vehicle fuel. Many utility service calls are “false alarms.” Checking meter status before dispatching crews prevents many unnecessary “truck rolls.” Similarly, crews use far less fuel when Smart Grid sensors can pinpoint a problem and mobile workforce applications can then route them directly to it. Smart Grid Business Software Ensures Regulatory Compliance Smart Grids can ensure compliance with private contracts and with regional, national, or international requirements by: Monitoring fulfillment of contract terms. Utilities can use one-hour interval meters to ensure that interruptible (“non-core”) customers actually reduce or eliminate deliveries as required. They can use the information to levy fines against contract violators. Monitoring regulations imposed on customers, such as maximum use during specific time periods. Using accurate time-stamped event history derived from intelligent devices distributed throughout the smart grid to monitor and report reliability statistics and risk compliance. Automating business processes and activities that ensure compliance with security and reliability measures (e.g. NERC-CIP 2-9). Grid Business Software Strengthens Utilities’ Connection to Customers While Reducing Customer Service Costs During outages, Smart Grid business software can: Identify outages more quickly. Software uses sensors to pinpoint outages and nested outage locations. They also permit utilities to ensure outage resolution at every meter location. Size outages more accurately, permitting utilities to dispatch crews that have the skills needed, in appropriate numbers. Provide updates on outage location and expected duration. This information helps call centers inform customers about the timing of service restoration. Smart Grids also facilitates display of outage maps for customer and public-service use. Smart Grids can significantly reduce the cost to: Connect and disconnect customers. Meters capable of remote disconnect can virtually eliminate the costs of field crews and vehicles previously required to change service from the old to the new residents of a metered property or disconnect customers for nonpayment. Resolve reports of voltage fluctuation. Smart Grids gather and report voltage and power quality data from meters and grid sensors, enabling utilities to pinpoint reported problems or resolve them before customers complain. Detect and resolve non-technical losses (e.g. theft). Smart Grids can identify illegal attempts to reconnect meters or to use electricity in supposedly vacant premises. They can also detect theft by comparing flows through delivery assets with billed consumption. Smart Grids also facilitate outreach to customers. By monitoring and analyzing consumption over time, utilities can: Identify customers with unusually high usage and contact them before they receive a bill. They can also suggest conservation techniques that might help to limit consumption. This can head off “high bill” complaints to the contact center. Note that such “high usage” or “additional charges apply because you are out of range” notices—frequently via text messaging—are already common among mobile phone providers. Help customers identify appropriate bill payment alternatives (budget billing, prepayment, etc.). Help customers find and reduce causes of over-consumption. There’s no waiting for bills in the mail before they even understand there is a problem. Utilities benefit not just through improved customer relations but also through limiting the size of bills from customers who might struggle to pay them. Where permitted, Smart Grids can open the doors to such new utility service offerings as: Monitoring properties. Landlords reduce costs of vacant properties when utilities notify them of unexpected energy or water consumption. Utilities can perform similar services for owners of vacation properties or the adult children of aging parents. Monitoring equipment. Power-use patterns can reveal a need for equipment maintenance. Smart Grids permit utilities to alert owners or managers to a need for maintenance or replacement. Facilitating home and small-business networks. Smart Grids can provide a gateway to equipment networks that automate control or let owners access equipment remotely. They also facilitate net metering, offering some utilities a path toward involvement in small-scale solar or wind generation. Prepayment plans that do not need special meters. Smart Grid Business Software Helps Customers Control Energy Costs There is no end to the ways Smart Grids help both small and large customers control energy costs. For instance: Multi-premises customers appreciate having all meters read on the same day so that they can more easily compare consumption at various sites. Customers in competitive regions can match their consumption profile (detailed via Smart Grid data) with specific offerings from competitive suppliers. Customers seeing inexplicable consumption patterns and power quality problems may investigate further. The result can be discovery of electrical problems that can be resolved through rewiring or maintenance—before more serious fires or accidents happen. Smart Grid Business Software Facilitates Use of Renewables Generation from wind and solar resources is a popular alternative to fossil fuel generation, which emits greenhouse gases. Wind and solar generation may also increase energy security in regions that currently import fossil fuel for use in generation. Utilities face many technical issues as they attempt to integrate intermittent resource generation into traditional grids, which traditionally handle only fully dispatchable generation. Smart Grid business software helps solves many of these issues by: Detecting sudden drops in production from renewables-generated electricity (wind and solar) and automatically triggering electricity storage and smart appliance response to compensate as needed. Supporting industry-standard distributed generation interconnection processes to reduce interconnection costs and avoid adding renewable supplies to locations already subject to grid congestion. Facilitating modeling and monitoring of locally generated supply from renewables and thus helping to maximize their use. Increasing the efficiency of “net metering” (through which utilities can use electricity generated by customers) by: Providing data for analysis. Integrating the production and consumption aspects of customer accounts. During non-peak periods, such techniques enable utilities to increase the percent of renewable generation in their supply mix. During peak periods, Smart Grid business software controls circuit reconfiguration to maximize available capacity. Conclusion Utility missions are changing. Yesterday, they focused on delivery of reasonably priced energy and water. Tomorrow, their missions will expand to encompass sustainable use and environmental improvement.Smart Grids are key to helping utilities achieve this expanded mission. But they come at a relatively high price. Utilities will need to invest heavily in new hardware, software, business process development, and staff training. Customer investments in home area networks and smart appliances will be large. Learning to change the energy and water consumption habits of a lifetime could ultimately prove even more formidable tasks.Smart Grid business software can ease the cost and difficulties inherent in a needed transition to a more flexible, reliable, responsive electricity grid. Justifying its implementation, however, requires a full understanding of the benefits it brings—benefits that can ultimately help customers, utilities, communities, and the world address global issues like energy security and climate change while minimizing costs and maximizing customer convenience. This white paper is available for download here. For further information about Oracle's Primavera Solutions for Utilities, please read our Utilities e-book.

    Read the article

  • ipmi - can't ping or remotely connect

    - by Fidel
    I've tried configuring the IPMI controller to accept remote connections, but I can't even ping it. Here is it status: #/usr/local/bin/ipmitool lan print 2 Set in Progress : Set Complete Auth Type Support : NONE PASSWORD Auth Type Enable : Callback : : User : NONE PASSWORD : Operator : PASSWORD : Admin : PASSWORD : OEM : IP Address Source : Static Address IP Address : 192.168.1.112 Subnet Mask : 255.255.255.0 MAC Address : 00:a0:a5:67:45:25 IP Header : TTL=0x40 Flags=0x40 Precedence=0x00 TOS=0x10 BMC ARP Control : ARP Responses Enabled, Gratuitous ARP Enabled Gratituous ARP Intrvl : 8.0 seconds Default Gateway IP : 192.168.1.1 Default Gateway MAC : 00:00:00:00:00:00 802.1q VLAN ID : Disabled 802.1q VLAN Priority : 0 RMCP+ Cipher Suites : 0,1,2,3 Cipher Suite Priv Max : uaaaXXXXXXXXXXX : X=Cipher Suite Unused : c=CALLBACK : u=USER : o=OPERATOR : a=ADMIN : O=OEM # /usr/local/bin/ipmitool user list 2 ID Name Enabled Callin Link Auth IPMI Msg Channel Priv Limit 1 true false true true USER 2 admin true false true true ADMINISTRATOR # /usr/local/bin/ipmitool channel getaccess 2 2 Maximum User IDs : 5 Enabled User IDs : 2 User ID : 2 User Name : admin Fixed Name : No Access Available : callback Link Authentication : enabled IPMI Messaging : enabled Privilege Level : ADMINISTRATOR # /usr/local/bin/ipmitool channel info 2 Channel 0x2 info: Channel Medium Type : 802.3 LAN Channel Protocol Type : IPMB-1.0 Session Support : multi-session Active Session Count : 0 Protocol Vendor ID : 7154 Volatile(active) Settings Alerting : disabled Per-message Auth : disabled User Level Auth : disabled Access Mode : always available Non-Volatile Settings Alerting : disabled Per-message Auth : disabled User Level Auth : disabled Access Mode : always available # /usr/local/bin/ipmitool chassis status System Power : on Power Overload : false Power Interlock : inactive Main Power Fault : false Power Control Fault : false Power Restore Policy : unknown Last Power Event : Chassis Intrusion : inactive Front-Panel Lockout : inactive Drive Fault : false Cooling/Fan Fault : false # arp Address HWtype HWaddress Flags Mask Iface 192.168.1.112 ether 00:A0:A5:67:45:25 C bond0 # /usr/local/bin/ipmitool -I lan -H 192.168.1.112 -U admin -P admin chassis power status Error: Unable to establish LAN session Unable to get Chassis Power Status In summary. It exists on the ARP list so arp's are being broadcast. I can't ping it and can't connect to it. Can anyone spot any glaring mistakes in the configuration? Many thanks, Fidel

    Read the article

  • Randomly displayed flashing lines, no response to all shortcuts, just power off. [syslog included]

    - by B. Roland
    Hello! I have an old machine, and I want to use for that to learn employees how to use Ubuntu, and to be easyer to switch from Windows. I've been installed 10.04, and updated, but this strange stuff is happend. Graphical installion failed, same strange thing. With alternate workd. Sometimes, when I boot up, a boot message displayed: Keyboard failure..., often diplayed after reboot, and after shutdown, when I haven't plugged off from AC. I replaced the keyboard yet, same failure... If I powered off, and plugged off from AC, no keyboard problems displayed in boot time. Details Configuration: Dell OptiPlex GX60 - in original cover, no changes. 256 MB DDR 166 MHz Intel® Celeron® Processor 2.40 GHz Dell 0C3207 Base Board I know, that is not enough, but I have three other Nec compuers, with nearly similar config, and they works well with 9.10, 10.04, 10.10. Live CDs I've been tried with 10.04 and 10.10, but the problem is displayed too. With 9.10 no strange things displayed, but it froze, during a simple apt-get install. Syslog An error loop is logged here, but I paste the whole startup and error lines. The flashing lines are displayed sometimes immediately after login, but sometimes after 10 minutes, but once occured, that nothing happend. Strange thing is displayed immediately after login: here. An other boot, after some minutes, strange lines, and loop in log appeard: here. The loop should be that: Jan 23 00:20:08 machine_name kernel: [ 46.782212] [drm:i915_gem_entervt_ioctl] *ERROR* Reenabling wedged hardware, good luck Jan 23 00:20:08 machine_name kernel: [ 47.100033] [drm:i915_hangcheck_elapsed] *ERROR* Hangcheck timer elapsed... GPU hung Jan 23 00:20:08 machine_name kernel: [ 47.100045] render error detected, EIR: 0x00000000 Jan 23 00:20:08 machine_name kernel: [ 47.101487] [drm:i915_do_wait_request] *ERROR* i915_do_wait_request returns -5 (awaiting 16 at 9) Jan 23 00:20:11 machine_name kernel: [ 49.152020] [drm:i915_gem_idle] *ERROR* hardware wedged Jan 23 00:20:11 machine_name gdm-simple-slave[1245]: WARNING: Unable to load file '/etc/gdm/custom.conf': No such file or directory Jan 23 00:20:11 machine_name acpid: client 1239[0:0] has disconnected Jan 23 00:20:11 machine_name acpid: client connected from 1247[0:0] Jan 23 00:20:11 machine_name acpid: 1 client rule loaded UPDATE Added syslog things: before errors, error loop, the complete shutdown(after the big updates): Jan 28 20:40:30 machine_name rtkit-daemon[1339]: Sucessfully called chroot. Jan 28 20:40:30 machine_name rtkit-daemon[1339]: Sucessfully dropped privileges. Jan 28 20:40:30 machine_name rtkit-daemon[1339]: Sucessfully limited resources. Jan 28 20:40:30 machine_name rtkit-daemon[1339]: Running. Jan 28 20:40:30 machine_name rtkit-daemon[1339]: Watchdog thread running. Jan 28 20:40:30 machine_name rtkit-daemon[1339]: Canary thread running. Jan 28 20:40:30 machine_name rtkit-daemon[1339]: Sucessfully made thread 1337 of process 1337 (n/a) owned by '1001' high priority at nice level -11. Jan 28 20:40:30 machine_name rtkit-daemon[1339]: Supervising 1 threads of 1 processes of 1 users. Jan 28 20:40:32 machine_name rtkit-daemon[1339]: Sucessfully made thread 1345 of process 1337 (n/a) owned by '1001' RT at priority 5. Jan 28 20:40:32 machine_name rtkit-daemon[1339]: Supervising 2 threads of 1 processes of 1 users. Jan 28 20:40:32 machine_name rtkit-daemon[1339]: Sucessfully made thread 1349 of process 1337 (n/a) owned by '1001' RT at priority 5. Jan 28 20:40:32 machine_name rtkit-daemon[1339]: Supervising 3 threads of 1 processes of 1 users. Jan 28 20:40:37 machine_name pulseaudio[1337]: ratelimit.c: 2 events suppressed Jan 28 20:41:33 machine_name AptDaemon: INFO: Initializing daemon Jan 28 20:41:44 machine_name kernel: [ 167.691563] lo: Disabled Privacy Extensions Jan 28 20:47:33 machine_name AptDaemon: INFO: Quiting due to inactivity Jan 28 20:47:33 machine_name AptDaemon: INFO: Shutdown was requested Jan 28 20:59:50 machine_name kernel: [ 1253.840513] lo: Disabled Privacy Extensions Jan 28 21:17:02 machine_name CRON[1874]: (root) CMD ( cd / && run-parts --report /etc/cron.hourly) Jan 28 21:17:38 machine_name kernel: [ 2321.553239] lo: Disabled Privacy Extensions Jan 28 22:07:44 machine_name kernel: [ 5327.840254] lo: Disabled Privacy Extensions Jan 28 22:17:02 machine_name CRON[2665]: (root) CMD ( cd / && run-parts --report /etc/cron.hourly) Jan 28 22:32:38 machine_name sudo: pam_sm_authenticate: Called Jan 28 22:32:38 machine_name sudo: pam_sm_authenticate: username = [some_user] Jan 28 22:32:38 machine_name sudo: pam_sm_authenticate: /home/some_user is already mounted Jan 28 22:57:03 machine_name kernel: [ 8286.641472] lo: Disabled Privacy Extensions Jan 28 22:57:24 machine_name sudo: pam_sm_authenticate: Called Jan 28 22:57:24 machine_name sudo: pam_sm_authenticate: username = [some_user] Jan 28 22:57:24 machine_name sudo: pam_sm_authenticate: /home/some_user is already mounted Jan 28 23:07:42 machine_name kernel: [ 8925.272030] [drm:i915_hangcheck_elapsed] *ERROR* Hangcheck timer elapsed... GPU hung Jan 28 23:07:42 machine_name kernel: [ 8925.272048] render error detected, EIR: 0x00000000 Jan 28 23:07:42 machine_name kernel: [ 8925.272093] [drm:i915_do_wait_request] *ERROR* i915_do_wait_request returns -5 (awaiting 171453 at 171452) Jan 28 23:07:45 machine_name kernel: [ 8928.868041] [drm:i915_gem_idle] *ERROR* hardware wedged Jan 28 23:08:10 machine_name acpid: client 925[0:0] has disconnected Jan 28 23:08:10 machine_name acpid: client connected from 8127[0:0] Jan 28 23:08:10 machine_name acpid: 1 client rule loaded Jan 28 23:08:11 machine_name kernel: [ 8955.046248] [drm:i915_gem_entervt_ioctl] *ERROR* Reenabling wedged hardware, good luck Jan 28 23:08:12 machine_name kernel: [ 8955.364016] [drm:i915_hangcheck_elapsed] *ERROR* Hangcheck timer elapsed... GPU hung Jan 28 23:08:12 machine_name kernel: [ 8955.364027] render error detected, EIR: 0x00000000 Jan 28 23:08:12 machine_name kernel: [ 8955.364407] [drm:i915_do_wait_request] *ERROR* i915_do_wait_request returns -5 (awaiting 171457 at 171452) Jan 28 23:08:14 machine_name kernel: [ 8957.472025] [drm:i915_gem_idle] *ERROR* hardware wedged Jan 28 23:08:14 machine_name acpid: client 8127[0:0] has disconnected Jan 28 23:08:14 machine_name acpid: client connected from 8141[0:0] Jan 28 23:08:14 machine_name acpid: 1 client rule loaded Jan 28 23:08:15 machine_name kernel: [ 8958.671722] [drm:i915_gem_entervt_ioctl] *ERROR* Reenabling wedged hardware, good luck Jan 28 23:08:15 machine_name kernel: [ 8958.988015] [drm:i915_hangcheck_elapsed] *ERROR* Hangcheck timer elapsed... GPU hung Jan 28 23:08:15 machine_name kernel: [ 8958.988026] render error detected, EIR: 0x00000000 Jan 28 23:08:15 machine_name kernel: [ 8958.989400] [drm:i915_do_wait_request] *ERROR* i915_do_wait_request returns -5 (awaiting 171459 at 171452) Jan 28 23:08:16 machine_name init: tty4 main process (848) killed by TERM signal Jan 28 23:08:16 machine_name init: tty5 main process (856) killed by TERM signal Jan 28 23:08:16 machine_name NetworkManager: nm_signal_handler(): Caught signal 15, shutting down normally. Jan 28 23:08:16 machine_name init: tty2 main process (874) killed by TERM signal Jan 28 23:08:16 machine_name init: tty3 main process (875) killed by TERM signal Jan 28 23:08:16 machine_name init: tty6 main process (877) killed by TERM signal Jan 28 23:08:16 machine_name init: cron main process (890) killed by TERM signal Jan 28 23:08:16 machine_name init: tty1 main process (1146) killed by TERM signal Jan 28 23:08:16 machine_name avahi-daemon[644]: Got SIGTERM, quitting. Jan 28 23:08:16 machine_name avahi-daemon[644]: Leaving mDNS multicast group on interface eth0.IPv4 with address 10.238.11.134. Jan 28 23:08:16 machine_name acpid: exiting Jan 28 23:08:16 machine_name init: avahi-daemon main process (644) terminated with status 255 Jan 28 23:08:17 machine_name kernel: Kernel logging (proc) stopped. Jan 28 23:09:00 machine_name kernel: imklog 4.2.0, log source = /proc/kmsg started. Jan 28 23:09:00 machine_name rsyslogd: [origin software="rsyslogd" swVersion="4.2.0" x-pid="516" x-info="http://www.rsyslog.com"] (re)start Jan 28 23:09:00 machine_name rsyslogd: rsyslogd's groupid changed to 103 Jan 28 23:09:00 machine_name rsyslogd: rsyslogd's userid changed to 101 Jan 28 23:09:00 machine_name rsyslogd-2039: Could no open output file '/dev/xconsole' [try http://www.rsyslog.com/e/2039 ] When I hit the On/Off button, the system shuts down normally. May be it a hardware problem, but I don't know... Can you say something useful to solve my problem?

    Read the article

  • Should we use RSS or Atom for feed generation?

    - by Henrik Söderlund
    For various reasons we are required to add feeds to our product. The main reason is to be able to say to potential buyers that "yes, we have feeds". We do not actually expect the feature to be used that much. Ideally we would like to provide both RSS and Atom feeds. However, at the moment we are severely pressed for time and are forced to select just one of these. Should we use Atom or RSS? Feature-wise we are fine with either, so I am only looking for information about the popularity and support for the various formats. Are there many feed readers out there without Atom support?

    Read the article

  • ‘Unleash the Power of Oracle WebLogic 12c: Architect, Deploy, Monitor and Tune JEE6’: Free Hands On Technical Workshop

    - by JuergenKress
    Come to our Workshop and get bootstrapped in the use of Oracle WebLogic 12c for high performance systems. The workshop, organised by Oracle Gold Partners - C2B2 Consulting -  and run by the Oracle Application Grid Certified Specialist Steve Milldge, will start with a simple WebLogic 12c system which will scale up to a distributed, reliable system designed to give zero downtime and support extreme throughput. When? Wednesday,25th of July Where? Oracle Corporation UK Ltd. One South Place, London EC2M 2RB Visit www.c2b2.co.uk/weblogic and join us for this unique technical event to learn, network and play with some cool technology! WebLogic Partner Community For regular information become a member in the WebLogic Partner Community please visit: http://www.oracle.com/partners/goto/wls-emea ( OPN account required). If you need support with your account please contact the Oracle Partner Business Center. Blog Twitter LinkedIn Mix Forum Wiki Technorati Tags: c2b2,ias to WebLogic,WebLogic basic,ias upgrade,C2B2,WebLogic,WebLogic Community,Oracle,OPN,Jürgen Kress

    Read the article

  • The Next Generation of Oracle Enterprise Manager Will Arrive in 7 Days!

    - by chung.wu
    Seven more days to go before we launch Oracle Enterprise Manager 11g. We invite you to join us for this exciting announcement. You may attend the event in person if you are going to be in New York City next Thursday (4/22) or over the web via our webcast. We will also be hosting a live simulcast event at the Collaborate conference in Las Vegas. Click the links below to learn more about event agenda and to register. Click here to register for the live event in New York City. Click here to register for the webcast. The simulcast event at Collaborate will be held in Palm B room on Level 3 of Mandalay Bay Convention Center starting at 9:45 a.m. local time.

    Read the article

  • Which Browser is the Best to Use When Running Your Laptop on Battery Power?

    - by Asian Angel
    Squeezing the maximum amount of usage time out of your laptop battery can be challenging at times…it all depends on the software you are using. One software we are all likely to be using is a browser to keep up with our online lives… If your laptop is older, then getting the most out of your laptop’s aging battery is definitely a must. The good folks over at the 7 Tutorials blog have done a comparison test to see which browser is the gentlest on your laptop’s battery and the results may surprise you. You can view the results by visiting the link below… Had better (or worse) luck with one of the browsers tested? Then make sure to share the results with your fellow readers in the comments! Test Comparison: Which Browser Will Make Your Laptop’s Battery Last Longer? [7 Tutorials] How to Own Your Own Website (Even If You Can’t Build One) Pt 3 How to Sync Your Media Across Your Entire House with XBMC How to Own Your Own Website (Even If You Can’t Build One) Pt 2

    Read the article

  • What techniques would you use for a next generation java web application?

    - by jakob
    I'm working at a site similar to Foursquare and Yelp, with approximately 100000 unique requests each week that generates content, growing steadily. We are currently using: Seam as Java web framework. MySQL as DB Hibernate as ORM Hibernate Search as Index EhCache for Caching. Since our site is slowly growing out of the current setup and has a lot of legacy code, it is time for us to start thinking about a major refactoring/changing setup. Web framework We are not ready to change the language but we are leaning towards Spring Web Framework, since: Seam is no more. Almost all of us have worked with Spring and liked it. DB and ORM We have done a little research and we are thinking about MongoDB. Index Do we need to have a separate Index if we use MongoDB? Cache ? So my question is basically: If you take Spring Web Framework and MongoDB into consideration, how would a good setup be for a web application that is growing and handles a lot of logged in users generating input and performing searches?

    Read the article

  • The Digital Video Recorder (DVR) is old news, the IP TV is the new generation.

    Its been more than 10 years since the first DVR came out in the US, the idea that you wont be wasting time by programming your video to record a show. Tivo was the first company to bring the idea of a hard disk to store your programs as well as the recurring shows recorded. Its being more than 10 years since that technology advance that improved the live of many families, yet after 10 years the technology hasnt improved much besides all cable and satellite companies provide their own device without...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • How can I use two video cards to power three screens?

    - by notatoad
    I have two Radeon 6450 graphics cards in my computer, with three screens. Only the screens plugged into the first graphics card are recognized and configurable in the displays setting panel. How can I use the displays plugged into my second graphics card? Both cards are present in lspci: 01:00.0 VGA compatible controller: ATI Technologies Inc NI Caicos [AMD RADEON HD 6450] 01:00.1 Audio device: ATI Technologies Inc NI Caicos HDMI Audio [AMD RADEON HD 6450] 02:00.0 VGA compatible controller: ATI Technologies Inc NI Caicos [AMD RADEON HD 6450] 02:00.1 Audio device: ATI Technologies Inc NI Caicos HDMI Audio [AMD RADEON HD 6450] I'm using the open source driver instead of the proprietary driver because the proprietary driver won't output 1440x2560.

    Read the article

< Previous Page | 69 70 71 72 73 74 75 76 77 78 79 80  | Next Page >