Search Results

Search found 14745 results on 590 pages for 'setting'.

Page 73/590 | < Previous Page | 69 70 71 72 73 74 75 76 77 78 79 80  | Next Page >

  • Setting up Virtual Hosts with Apache on Windows 2008 server for multiple sites. Complicated setup, including subversion

    - by Roeland
    I am setting up apache on my windows 2008 server at my home. It will serve 2 functions. Subversion hosting to allow me and some others to manage company documents with version control Local website hosting for web development. Will need to run several websites since I generally work on more then one site at a time. Heres what I have done so far. I set up subversion and apache 2.2 using some walk troughs. I changed the default port to 1337. (im a nerd) Using dyndns.com I created a domain to forward to my home ip which is dynamic. ( company.gotdns.org) I then went into my DNS for my company.com and added a record to point repo.company.com to company.gotdns.org At this point people who need access to my file repository can access by going to repo.company.com/repo which is good so far. My question comes on the next step, setting up virtual hosts with apache. Ideally I would like to have my local website be viewable by some others in the company from their homes. So, say I am working on site1, I would like to have them be able to view this by going site1.roeland.bythepixel.com. At the same time, I would like to have site10.wouter.bythepixel.com go to his local setup for site10. What I have done for this: I went into my DNS for company.com and added a record to point roeland.company.com to company.gotdns.org (which translates to my ip). I added code to my httpd-vhosts.conf (listed at bottom) I added code to my host file (listed at bottom) Hah, so of course this doenst work as excepted.. going to site1.roeland.bythepixel.com doesnt bring up my test1 site. Could anyone point me where I may be going wrong? Thanks! hosts: 127.0.0.1 localhost 127.0.0.1 sensenich.roeland.bythepixel.com ::1 localhost httpd-vhosts.conf: <VirtualHost *:80> ServerAdmin [email protected] DocumentRoot "F:/Current Projects/sensenich.com" ServerName sensenich.roeland.bythepixel.com ErrorLog "logs/sensenich.roeland.bythepixel.com-error.log" CustomLog "logs/sensenich.roeland.bythepixel.com-access.log" common </VirtualHost>

    Read the article

  • Django tutorial says I haven't set DATABASE_ENGINE setting yet... but I have

    - by Joe
    I'm working through the Django tutorial and receiving the following error when I run the initial python manage.py syncdb: Traceback (most recent call last): File "manage.py", line 11, in <module> execute_manager(settings) File "/Library/Python/2.6/site-packages/django/core/management/__init__.py", line 362 in execute_manager utility.execute() File "/Library/Python/2.6/site-packages/django/core/management/__init__.py", line 303, in execute self.fetch_command(subcommand).run_from_argv(self.argv) File "/Library/Python/2.6/site-packages/django/core/management/base.py", line 195, in run_from_argv self.execute(*args, **options.__dict__) File "/Library/Python/2.6/site-packages/django/core/management/base.py", line 222, in execute output = self.handle(*args, **options) File "/Library/Python/2.6/site-packages/django/core/management/base.py", line 351, in handle return self.handle_noargs(**options) File "/Library/Python/2.6/site-packages/django/core/management/commands/syncdb.py", line 49, in handle_noargs cursor = connection.cursor() File "/Library/Python/2.6/site-packages/django/db/backends/dummy/base.py", line 15, in complain raise ImproperlyConfigured, "You haven't set the DATABASE_ENGINE setting yet." django.core.exceptions.ImproperlyConfigured: You haven't set the DATABASE_ENGINE setting yet. My settings.py looks like: DATABASES = { 'default': { 'ENGINE': 'django.db.backends.mysql', # Add 'postgresql_psycopg2', 'postgresql', 'mysql', 'sqlite3' or 'oracle'. 'NAME': 'dj_tut', # Or path to database file if using sqlite3. 'USER': '', # Not used with sqlite3. 'PASSWORD': '', # Not used with sqlite3. 'HOST': '', # Set to empty string for localhost. Not used with sqlite3. 'PORT': '', # Set to empty string for default. Not used with sqlite3. } } I'm guessing this is something simple, but why isn't it seeing the ENGINE setting?

    Read the article

  • Garbled text in Screen [closed]

    - by Prabin Dahal
    The graphical Interface in my system is garbled with some text. At the beginning I thought it was due to java and tomcat that I installed. But after removing java and tomcat, it is still the same. I am using ubuntu server and i have installed xfce desktop environment with oboard softkey I have added my dmesg output to this message. What is the problem here. I am not able to figure it out. Thank you for your help. Prabin [ 0.390936] usbcore: registered new interface driver usbfs [ 0.391006] usbcore: registered new interface driver hub [ 0.391147] usbcore: registered new device driver usb [ 0.391580] PCI: Using ACPI for IRQ routing [ 0.400509] PCI: pci_cache_line_size set to 64 bytes [ 0.400669] reserve RAM buffer: 000000000009ec00 - 000000000009ffff [ 0.400681] reserve RAM buffer: 000000007f597000 - 000000007fffffff [ 0.400699] reserve RAM buffer: 000000007f6f0000 - 000000007fffffff [ 0.401135] NetLabel: Initializing [ 0.401155] NetLabel: domain hash size = 128 [ 0.401168] NetLabel: protocols = UNLABELED CIPSOv4 [ 0.401212] NetLabel: unlabeled traffic allowed by default [ 0.401466] HPET: 3 timers in total, 0 timers will be used for per-cpu timer [ 0.401494] hpet0: at MMIO 0xfed00000, IRQs 2, 8, 0 [ 0.401520] hpet0: 3 comparators, 64-bit 14.318180 MHz counter [ 0.408228] Switching to clocksource hpet [ 0.434341] AppArmor: AppArmor Filesystem Enabled [ 0.434447] pnp: PnP ACPI init [ 0.434531] ACPI: bus type pnp registered [ 0.434784] pnp 00:00: [bus 00-ff] [ 0.434794] pnp 00:00: [io 0x0cf8-0x0cff] [ 0.434804] pnp 00:00: [io 0x0000-0x0cf7 window] [ 0.434813] pnp 00:00: [io 0x0d00-0xffff window] [ 0.434822] pnp 00:00: [mem 0x000a0000-0x000bffff window] [ 0.434831] pnp 00:00: [mem 0x00000000 window] [ 0.434840] pnp 00:00: [mem 0x80000000-0xffffffff window] [ 0.435018] pnp 00:00: Plug and Play ACPI device, IDs PNP0a08 PNP0a03 (active) [ 0.435526] pnp 00:01: [mem 0xe0000000-0xefffffff] [ 0.435537] pnp 00:01: [mem 0x7f700000-0x7f7fffff] [ 0.435545] pnp 00:01: [mem 0x7f800000-0x7fffffff] [ 0.435554] pnp 00:01: [mem 0xfee00000-0xfeefffff] [ 0.435727] system 00:01: [mem 0xe0000000-0xefffffff] has been reserved [ 0.435754] system 00:01: [mem 0x7f700000-0x7f7fffff] has been reserved [ 0.435775] system 00:01: [mem 0x7f800000-0x7fffffff] has been reserved [ 0.435796] system 00:01: [mem 0xfee00000-0xfeefffff] has been reserved [ 0.435818] system 00:01: Plug and Play ACPI device, IDs PNP0c01 (active) [ 0.436233] pnp 00:02: [io 0x0000-0xffffffffffffffff disabled] [ 0.436245] pnp 00:02: [io 0x0000-0xffffffffffffffff disabled] [ 0.436414] system 00:02: Plug and Play ACPI device, IDs PNP0c02 (active) [ 0.436512] pnp 00:03: [io 0x0060] [ 0.436521] pnp 00:03: [io 0x0064] [ 0.436548] pnp 00:03: [irq 1] [ 0.436682] pnp 00:03: Plug and Play ACPI device, IDs PNP0303 PNP030b (active) [ 0.436825] pnp 00:04: [irq 12] [ 0.436958] pnp 00:04: Plug and Play ACPI device, IDs PNP0f03 PNP0f13 (active) [ 0.437835] pnp 00:05: [io 0x03f8-0x03ff] [ 0.437861] pnp 00:05: [irq 4] [ 0.437870] pnp 00:05: [dma 0 disabled] [ 0.438142] pnp 00:05: Plug and Play ACPI device, IDs PNP0501 (active) [ 0.439014] pnp 00:06: [io 0x02f8-0x02ff] [ 0.439036] pnp 00:06: [irq 3] [ 0.439045] pnp 00:06: [dma 0 disabled] [ 0.439297] pnp 00:06: Plug and Play ACPI device, IDs PNP0501 (active) [ 0.439346] pnp 00:07: [io 0x0000-0x000f] [ 0.439355] pnp 00:07: [io 0x0081-0x0083] [ 0.439363] pnp 00:07: [io 0x0087] [ 0.439371] pnp 00:07: [io 0x0089-0x008b] [ 0.439380] pnp 00:07: [io 0x008f] [ 0.439388] pnp 00:07: [io 0x00c0-0x00df] [ 0.439563] system 00:07: Plug and Play ACPI device, IDs PNP0c01 (active) [ 0.439617] pnp 00:08: [io 0x0070-0x0077] [ 0.439639] pnp 00:08: [irq 8] [ 0.439751] pnp 00:08: Plug and Play ACPI device, IDs PNP0b00 (active) [ 0.439788] pnp 00:09: [io 0x0061] [ 0.439893] pnp 00:09: Plug and Play ACPI device, IDs PNP0800 (active) [ 0.439977] pnp 00:0a: [io 0x0010-0x001f] [ 0.439986] pnp 00:0a: [io 0x0022-0x003f] [ 0.439994] pnp 00:0a: [io 0x0044-0x005f] [ 0.440055] pnp 00:0a: [io 0x0063] [ 0.440063] pnp 00:0a: [io 0x0065] [ 0.440071] pnp 00:0a: [io 0x0067-0x006f] [ 0.440079] pnp 00:0a: [io 0x0072-0x007f] [ 0.440086] pnp 00:0a: [io 0x0080] [ 0.440094] pnp 00:0a: [io 0x0084-0x0086] [ 0.440102] pnp 00:0a: [io 0x0088] [ 0.440109] pnp 00:0a: [io 0x008c-0x008e] [ 0.440117] pnp 00:0a: [io 0x0090-0x009f] [ 0.440125] pnp 00:0a: [io 0x00a2-0x00bf] [ 0.440133] pnp 00:0a: [io 0x00e0-0x00ef] [ 0.440141] pnp 00:0a: [io 0x04d0-0x04d1] [ 0.440150] pnp 00:0a: [io 0x0000-0xffffffffffffffff disabled] [ 0.440160] pnp 00:0a: [io 0x0000-0xffffffffffffffff disabled] [ 0.440168] pnp 00:0a: [io 0x03f4] [ 0.440175] pnp 00:0a: [io 0x03f5] [ 0.440183] pnp 00:0a: [io 0x0374] [ 0.440190] pnp 00:0a: [io 0x0375] [ 0.440405] system 00:0a: [io 0x04d0-0x04d1] has been reserved [ 0.440432] system 00:0a: [io 0x03f4] has been reserved [ 0.440451] system 00:0a: [io 0x03f5] has been reserved [ 0.440469] system 00:0a: [io 0x0374] has been reserved [ 0.440488] system 00:0a: [io 0x0375] has been reserved [ 0.440508] system 00:0a: Plug and Play ACPI device, IDs PNP0c02 (active) [ 0.440550] pnp 00:0b: [io 0x00f0-0x00ff] [ 0.440572] pnp 00:0b: [irq 13] [ 0.440691] pnp 00:0b: Plug and Play ACPI device, IDs PNP0c04 (active) [ 0.440770] pnp 00:0c: [io 0x0810] [ 0.440779] pnp 00:0c: [io 0x0800-0x080f] [ 0.440787] pnp 00:0c: [io 0xffff] [ 0.440947] system 00:0c: [io 0x0810] has been reserved [ 0.440970] system 00:0c: [io 0x0800-0x080f] has been reserved [ 0.440989] system 00:0c: [io 0xffff] has been reserved [ 0.441010] system 00:0c: Plug and Play ACPI device, IDs PNP0c02 (active) [ 0.441620] pnp 00:0d: [io 0x0900-0x097f] [ 0.441630] pnp 00:0d: [io 0x09c0-0x09ff] [ 0.441639] pnp 00:0d: [io 0x0400-0x043f] [ 0.441647] pnp 00:0d: [io 0x0480-0x04bf] [ 0.441656] pnp 00:0d: [mem 0xfec00000-0xfec85fff] [ 0.441664] pnp 00:0d: [mem 0xfed1c000-0xfed1ffff] [ 0.441673] pnp 00:0d: [mem 0x000c0000-0x000dffff] [ 0.441689] pnp 00:0d: [mem 0x000e0000-0x000effff] [ 0.441697] pnp 00:0d: [mem 0x000f0000-0x000fffff] [ 0.441706] pnp 00:0d: [mem 0xff800000-0xffffffff] [ 0.441911] system 00:0d: [io 0x0900-0x097f] has been reserved [ 0.441935] system 00:0d: [io 0x09c0-0x09ff] has been reserved [ 0.441955] system 00:0d: [io 0x0400-0x043f] has been reserved [ 0.441975] system 00:0d: [io 0x0480-0x04bf] has been reserved [ 0.441997] system 00:0d: [mem 0xfec00000-0xfec85fff] could not be reserved [ 0.442019] system 00:0d: [mem 0xfed1c000-0xfed1ffff] has been reserved [ 0.442040] system 00:0d: [mem 0x000c0000-0x000dffff] could not be reserved [ 0.442061] system 00:0d: [mem 0x000e0000-0x000effff] could not be reserved [ 0.442082] system 00:0d: [mem 0x000f0000-0x000fffff] could not be reserved [ 0.442103] system 00:0d: [mem 0xff800000-0xffffffff] has been reserved [ 0.442126] system 00:0d: Plug and Play ACPI device, IDs PNP0c01 (active) [ 0.442308] pnp 00:0e: [mem 0xfed00000-0xfed003ff] [ 0.442454] pnp 00:0e: Plug and Play ACPI device, IDs PNP0103 (active) [ 0.442569] pnp 00:0f: [mem 0x7f6f0000-0x7f6fffff] [ 0.442762] system 00:0f: [mem 0x7f6f0000-0x7f6fffff] has been reserved [ 0.442788] system 00:0f: Plug and Play ACPI device, IDs PNP0c01 (active) [ 0.443360] pnp: PnP ACPI: found 16 devices [ 0.443378] ACPI: ACPI bus type pnp unregistered [ 0.443395] PnPBIOS: Disabled by ACPI PNP [ 0.486106] PCI: max bus depth: 3 pci_try_num: 4 [ 0.486189] pci 0000:00:1c.0: PCI bridge to [bus 01-01] [ 0.486217] pci 0000:00:1c.0: bridge window [io 0xe000-0xefff] [ 0.486241] pci 0000:00:1c.0: bridge window [mem 0xd0100000-0xd01fffff] [ 0.486266] pci 0000:00:1c.0: bridge window [mem 0xff700000-0xff7fffff pref] [ 0.486298] pci 0000:03:01.0: PCI bridge to [bus 04-04] [ 0.486319] pci 0000:03:01.0: bridge window [io 0xd000-0xdfff] [ 0.486348] pci 0000:03:01.0: bridge window [mem 0xd0000000-0xd00fffff] [ 0.486374] pci 0000:03:01.0: bridge window [mem 0xff600000-0xff6fffff 64bit pref] [ 0.486406] pci 0000:03:02.0: PCI bridge to [bus 05-05] [ 0.486444] pci 0000:03:03.0: PCI bridge to [bus 06-06] [ 0.486479] pci 0000:02:00.0: PCI bridge to [bus 03-06] [ 0.486499] pci 0000:02:00.0: bridge window [io 0xd000-0xdfff] [ 0.486522] pci 0000:02:00.0: bridge window [mem 0xd0000000-0xd00fffff] [ 0.486545] pci 0000:02:00.0: bridge window [mem 0xff600000-0xff6fffff 64bit pref] [ 0.486575] pci 0000:00:1c.1: PCI bridge to [bus 02-06] [ 0.486593] pci 0000:00:1c.1: bridge window [io 0xd000-0xdfff] [ 0.486615] pci 0000:00:1c.1: bridge window [mem 0xd0000000-0xd00fffff] [ 0.486637] pci 0000:00:1c.1: bridge window [mem 0xff600000-0xff6fffff pref] [ 0.486710] pci 0000:00:1c.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 0.486735] pci 0000:00:1c.0: setting latency timer to 64 [ 0.486774] pci 0000:00:1c.1: PCI INT B -> GSI 17 (level, low) -> IRQ 17 [ 0.486796] pci 0000:00:1c.1: setting latency timer to 64 [ 0.486817] pci 0000:02:00.0: setting latency timer to 64 [ 0.486836] pci 0000:03:01.0: setting latency timer to 64 [ 0.486858] pci 0000:03:02.0: setting latency timer to 64 [ 0.486880] pci 0000:03:03.0: setting latency timer to 64 [ 0.486893] pci_bus 0000:00: resource 4 [io 0x0000-0x0cf7] [ 0.486902] pci_bus 0000:00: resource 5 [io 0x0d00-0xffff] [ 0.486912] pci_bus 0000:00: resource 6 [mem 0x000a0000-0x000bffff] [ 0.486922] pci_bus 0000:00: resource 7 [mem 0x80000000-0xffffffff] [ 0.486932] pci_bus 0000:01: resource 0 [io 0xe000-0xefff] [ 0.486941] pci_bus 0000:01: resource 1 [mem 0xd0100000-0xd01fffff] [ 0.486951] pci_bus 0000:01: resource 2 [mem 0xff700000-0xff7fffff pref] [ 0.486961] pci_bus 0000:02: resource 0 [io 0xd000-0xdfff] [ 0.486970] pci_bus 0000:02: resource 1 [mem 0xd0000000-0xd00fffff] [ 0.486980] pci_bus 0000:02: resource 2 [mem 0xff600000-0xff6fffff pref] [ 0.486989] pci_bus 0000:03: resource 0 [io 0xd000-0xdfff] [ 0.486998] pci_bus 0000:03: resource 1 [mem 0xd0000000-0xd00fffff] [ 0.487008] pci_bus 0000:03: resource 2 [mem 0xff600000-0xff6fffff 64bit pref] [ 0.487018] pci_bus 0000:04: resource 0 [io 0xd000-0xdfff] [ 0.487028] pci_bus 0000:04: resource 1 [mem 0xd0000000-0xd00fffff] [ 0.487038] pci_bus 0000:04: resource 2 [mem 0xff600000-0xff6fffff 64bit pref] [ 0.487177] NET: Registered protocol family 2 [ 0.487405] IP route cache hash table entries: 32768 (order: 5, 131072 bytes) [ 0.488397] TCP established hash table entries: 131072 (order: 8, 1048576 bytes) [ 0.489792] TCP bind hash table entries: 65536 (order: 7, 524288 bytes) [ 0.490493] TCP: Hash tables configured (established 131072 bind 65536) [ 0.490525] TCP reno registered [ 0.490551] UDP hash table entries: 512 (order: 2, 16384 bytes) [ 0.490590] UDP-Lite hash table entries: 512 (order: 2, 16384 bytes) [ 0.490898] NET: Registered protocol family 1 [ 0.490970] pci 0000:00:02.0: Boot video device [ 0.491052] pci 0000:00:1d.0: PCI INT A -> GSI 20 (level, low) -> IRQ 20 [ 0.491092] pci 0000:00:1d.0: PCI INT A disabled [ 0.491134] pci 0000:00:1d.1: PCI INT B -> GSI 21 (level, low) -> IRQ 21 [ 0.491174] pci 0000:00:1d.1: PCI INT B disabled [ 0.491220] pci 0000:00:1d.2: PCI INT C -> GSI 22 (level, low) -> IRQ 22 [ 0.491259] pci 0000:00:1d.2: PCI INT C disabled [ 0.491307] pci 0000:00:1d.7: PCI INT D -> GSI 23 (level, low) -> IRQ 23 [ 0.864431] Freeing initrd memory: 13820k freed [ 2.088042] pci 0000:00:1d.7: EHCI: BIOS handoff failed (BIOS bug?) 01010001 [ 2.088207] pci 0000:00:1d.7: PCI INT D disabled [ 2.088267] PCI: CLS 64 bytes, default 64 [ 2.089248] audit: initializing netlink socket (disabled) [ 2.089287] type=2000 audit(1349363630.084:1): initialized [ 2.144783] highmem bounce pool size: 64 pages [ 2.144808] HugeTLB registered 2 MB page size, pre-allocated 0 pages [ 2.160057] VFS: Disk quotas dquot_6.5.2 [ 2.160232] Dquot-cache hash table entries: 1024 (order 0, 4096 bytes) [ 2.161716] fuse init (API version 7.17) [ 2.161995] msgmni has been set to 1713 [ 2.162925] Block layer SCSI generic (bsg) driver version 0.4 loaded (major 253) [ 2.163008] io scheduler noop registered [ 2.163023] io scheduler deadline registered [ 2.163048] io scheduler cfq registered (default) [ 2.163339] pcieport 0000:00:1c.0: setting latency timer to 64 [ 2.163530] pcieport 0000:00:1c.1: setting latency timer to 64 [ 2.163706] pcieport 0000:02:00.0: setting latency timer to 64 [ 2.163873] pcieport 0000:03:01.0: setting latency timer to 64 [ 2.163964] pcieport 0000:03:01.0: irq 40 for MSI/MSI-X [ 2.164193] pcieport 0000:03:02.0: setting latency timer to 64 [ 2.164272] pcieport 0000:03:02.0: irq 41 for MSI/MSI-X [ 2.164453] pcieport 0000:03:03.0: setting latency timer to 64 [ 2.164531] pcieport 0000:03:03.0: irq 42 for MSI/MSI-X [ 2.164783] pcieport 0000:00:1c.0: Signaling PME through PCIe PME interrupt [ 2.164801] pci 0000:01:00.0: Signaling PME through PCIe PME interrupt [ 2.164816] pcie_pme 0000:00:1c.0:pcie01: service driver pcie_pme loaded [ 2.164853] pcieport 0000:00:1c.1: Signaling PME through PCIe PME interrupt [ 2.164867] pcieport 0000:02:00.0: Signaling PME through PCIe PME interrupt [ 2.164880] pcieport 0000:03:01.0: Signaling PME through PCIe PME interrupt [ 2.164892] pci 0000:04:00.0: Signaling PME through PCIe PME interrupt [ 2.164904] pcieport 0000:03:02.0: Signaling PME through PCIe PME interrupt [ 2.164917] pcieport 0000:03:03.0: Signaling PME through PCIe PME interrupt [ 2.164932] pcie_pme 0000:00:1c.1:pcie01: service driver pcie_pme loaded [ 2.164988] pci_hotplug: PCI Hot Plug PCI Core version: 0.5 [ 2.165115] pciehp 0000:00:1c.0:pcie04: HPC vendor_id 8086 device_id 8110 ss_vid 8086 ss_did 8119 [ 2.165177] pciehp 0000:00:1c.0:pcie04: service driver pciehp loaded [ 2.165199] pciehp 0000:00:1c.1:pcie04: HPC vendor_id 8086 device_id 8112 ss_vid 8086 ss_did 8119 [ 2.165260] pciehp 0000:00:1c.1:pcie04: service driver pciehp loaded [ 2.165290] pciehp: PCI Express Hot Plug Controller Driver version: 0.4 [ 2.165488] intel_idle: MWAIT substates: 0x3020220 [ 2.165508] intel_idle: v0.4 model 0x1C [ 2.165513] intel_idle: lapic_timer_reliable_states 0x2 [ 2.165519] Marking TSC unstable due to TSC halts in idle states deeper than C2 [ 2.165779] input: Lid Switch as /devices/LNXSYSTM:00/device:00/PNP0C0D:00/input/input0 [ 2.165855] ACPI: Lid Switch [LID] [ 2.165983] input: Power Button as /devices/LNXSYSTM:00/device:00/PNP0C0C:00/input/input1 [ 2.166005] ACPI: Power Button [PWRB] [ 2.173811] thermal LNXTHERM:00: registered as thermal_zone0 [ 2.173829] ACPI: Thermal Zone [TZ00] (48 C) [ 2.174004] thermal LNXTHERM:01: registered as thermal_zone1 [ 2.174018] ACPI: Thermal Zone [TZ01] (34 C) [ 2.174194] thermal LNXTHERM:02: registered as thermal_zone2 [ 2.174207] ACPI: Thermal Zone [TZ02] (34 C) [ 2.174378] thermal LNXTHERM:03: registered as thermal_zone3 [ 2.174392] ACPI: Thermal Zone [TZ03] (34 C) [ 2.174503] ERST: Table is not found! [ 2.174513] GHES: HEST is not enabled! [ 2.174601] isapnp: Scanning for PnP cards... [ 2.176175] Serial: 8250/16550 driver, 32 ports, IRQ sharing enabled [ 2.196702] serial8250: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A [ 2.292409] serial8250: ttyS1 at I/O 0x2f8 (irq = 3) is a 16550A [ 2.528909] isapnp: No Plug & Play device found [ 2.588733] 00:05: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A [ 2.624523] 00:06: ttyS1 at I/O 0x2f8 (irq = 3) is a 16550A [ 2.640702] Linux agpgart interface v0.103 [ 2.645138] brd: module loaded [ 2.647452] loop: module loaded [ 2.648149] pata_acpi 0000:00:1f.1: setting latency timer to 64 [ 2.649238] Fixed MDIO Bus: probed [ 2.649315] tun: Universal TUN/TAP device driver, 1.6 [ 2.649327] tun: (C) 1999-2004 Max Krasnyansky <[email protected]> [ 2.649524] PPP generic driver version 2.4.2 [ 2.649824] ehci_hcd: USB 2.0 'Enhanced' Host Controller (EHCI) Driver [ 2.649884] ehci_hcd 0000:00:1d.7: PCI INT D -> GSI 23 (level, low) -> IRQ 23 [ 2.649937] ehci_hcd 0000:00:1d.7: setting latency timer to 64 [ 2.649946] ehci_hcd 0000:00:1d.7: EHCI Host Controller [ 2.650082] ehci_hcd 0000:00:1d.7: new USB bus registered, assigned bus number 1 [ 2.650148] ehci_hcd 0000:00:1d.7: debug port 1 [ 2.654045] ehci_hcd 0000:00:1d.7: cache line size of 64 is not supported [ 2.654093] ehci_hcd 0000:00:1d.7: irq 23, io mem 0xd02c4000 [ 2.668035] ehci_hcd 0000:00:1d.7: USB 2.0 started, EHCI 1.00 [ 2.668392] hub 1-0:1.0: USB hub found [ 2.668413] hub 1-0:1.0: 8 ports detected [ 2.668618] ohci_hcd: USB 1.1 'Open' Host Controller (OHCI) Driver [ 2.668666] uhci_hcd: USB Universal Host Controller Interface driver [ 2.668726] uhci_hcd 0000:00:1d.0: PCI INT A -> GSI 20 (level, low) -> IRQ 20 [ 2.668751] uhci_hcd 0000:00:1d.0: setting latency timer to 64 [ 2.668759] uhci_hcd 0000:00:1d.0: UHCI Host Controller [ 2.668910] uhci_hcd 0000:00:1d.0: new USB bus registered, assigned bus number 2 [ 2.668981] uhci_hcd 0000:00:1d.0: irq 20, io base 0x0000f040 [ 2.669335] hub 2-0:1.0: USB hub found [ 2.669355] hub 2-0:1.0: 2 ports detected [ 2.669508] uhci_hcd 0000:00:1d.1: PCI INT B -> GSI 21 (level, low) -> IRQ 21 [ 2.669531] uhci_hcd 0000:00:1d.1: setting latency timer to 64 [ 2.669538] uhci_hcd 0000:00:1d.1: UHCI Host Controller [ 2.669675] uhci_hcd 0000:00:1d.1: new USB bus registered, assigned bus number 3 [ 2.669739] uhci_hcd 0000:00:1d.1: irq 21, io base 0x0000f020 [ 2.670099] hub 3-0:1.0: USB hub found [ 2.670118] hub 3-0:1.0: 2 ports detected [ 2.670271] uhci_hcd 0000:00:1d.2: PCI INT C -> GSI 22 (level, low) -> IRQ 22 [ 2.670295] uhci_hcd 0000:00:1d.2: setting latency timer to 64 [ 2.670302] uhci_hcd 0000:00:1d.2: UHCI Host Controller [ 2.670435] uhci_hcd 0000:00:1d.2: new USB bus registered, assigned bus number 4 [ 2.670502] uhci_hcd 0000:00:1d.2: irq 22, io base 0x0000f000 [ 2.670869] hub 4-0:1.0: USB hub found [ 2.670888] hub 4-0:1.0: 2 ports detected [ 2.671186] usbcore: registered new interface driver libusual [ 2.671332] i8042: PNP: PS/2 Controller [PNP0303:PS2K,PNP0f03:PS2M] at 0x60,0x64 irq 1,12 [ 2.673408] serio: i8042 KBD port at 0x60,0x64 irq 1 [ 2.673437] serio: i8042 AUX port at 0x60,0x64 irq 12 [ 2.673844] mousedev: PS/2 mouse device common for all mice [ 2.674272] rtc_cmos 00:08: RTC can wake from S4 [ 2.674482] rtc_cmos 00:08: rtc core: registered rtc_cmos as rtc0 [ 2.674529] rtc0: alarms up to one year, y3k, 242 bytes nvram, hpet irqs [ 2.674691] device-mapper: uevent: version 1.0.3 [ 2.674903] device-mapper: ioctl: 4.22.0-ioctl (2011-10-19) initialised: [email protected] [ 2.675024] EISA: Probing bus 0 at eisa.0 [ 2.675037] EISA: Cannot allocate resource for mainboard [ 2.675050] Cannot allocate resource for EISA slot 1 [ 2.675061] Cannot allocate resource for EISA slot 2 [ 2.675072] Cannot allocate resource for EISA slot 3 [ 2.675083] Cannot allocate resource for EISA slot 4 [ 2.675094] Cannot allocate resource for EISA slot 5 [ 2.675105] Cannot allocate resource for EISA slot 6 [ 2.675116] Cannot allocate resource for EISA slot 7 [ 2.675127] Cannot allocate resource for EISA slot 8 [ 2.675137] EISA: Detected 0 cards. [ 2.675161] cpufreq-nforce2: No nForce2 chipset. [ 2.675401] cpuidle: using governor ladder [ 2.675786] cpuidle: using governor menu [ 2.675797] EFI Variables Facility v0.08 2004-May-17 [ 2.676429] TCP cubic registered [ 2.676751] NET: Registered protocol family 10 [ 2.678031] NET: Registered protocol family 17 [ 2.678052] Registering the dns_resolver key type [ 2.678107] Using IPI No-Shortcut mode [ 2.678515] PM: Hibernation image not present or could not be loaded. [ 2.678543] registered taskstats version 1 [ 2.701145] Magic number: 0:84:234 [ 2.701312] rtc_cmos 00:08: setting system clock to 2012-10-04 15:13:51 UTC (1349363631) [ 2.702280] BIOS EDD facility v0.16 2004-Jun-25, 0 devices found [ 2.702294] EDD information not available. [ 2.702858] Freeing unused kernel memory: 740k freed [ 2.703630] Write protecting the kernel text: 5816k [ 2.703692] Write protecting the kernel read-only data: 2376k [ 2.703706] NX-protecting the kernel data: 4424k [ 2.751226] udevd[84]: starting version 175 [ 2.980162] usb 1-1: new high-speed USB device number 2 using ehci_hcd [ 3.001394] r8169 Gigabit Ethernet driver 2.3LK-NAPI loaded [ 3.001474] r8169 0000:01:00.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 3.001554] r8169 0000:01:00.0: setting latency timer to 64 [ 3.001654] r8169 0000:01:00.0: irq 43 for MSI/MSI-X [ 3.004220] r8169 0000:01:00.0: eth0: RTL8168c/8111c at 0xf8416000, 00:18:92:03:10:46, XID 1c4000c0 IRQ 43 [ 3.004254] r8169 0000:01:00.0: eth0: jumbo features [frames: 6128 bytes, tx checksumming: ko] [ 3.004347] r8169 Gigabit Ethernet driver 2.3LK-NAPI loaded [ 3.005085] r8169 0000:04:00.0: PCI INT A -> GSI 18 (level, low) -> IRQ 18 [ 3.005182] r8169 0000:04:00.0: setting latency timer to 64 [ 3.005292] r8169 0000:04:00.0: irq 44 for MSI/MSI-X [ 3.007187] r8169 0000:04:00.0: eth1: RTL8168c/8111c at 0xf8418000, 00:18:92:03:10:47, XID 1c4000c0 IRQ 44 [ 3.007224] r8169 0000:04:00.0: eth1: jumbo features [frames: 6128 bytes, tx checksumming: ko] [ 3.034417] pata_sch 0000:00:1f.1: version 0.2 [ 3.034518] pata_sch 0000:00:1f.1: setting latency timer to 64 [ 3.036698] scsi0 : pata_sch [ 3.039842] scsi1 : pata_sch [ 3.040913] ata1: PATA max UDMA/100 cmd 0x1f0 ctl 0x3f6 bmdma 0xf060 irq 14 [ 3.040940] ata2: PATA max UDMA/100 cmd 0x170 ctl 0x376 bmdma 0xf068 irq 15 [ 3.131850] Initializing USB Mass Storage driver... [ 3.136405] scsi2 : usb-storage 1-1:1.0 [ 3.136642] usbcore: registered new interface driver usb-storage [ 3.136656] USB Mass Storage support registered. [ 3.524465] usb 3-1: new low-speed USB device number 2 using uhci_hcd [ 3.968144] usb 3-2: new full-speed USB device number 3 using uhci_hcd [ 4.137903] scsi 2:0:0:0: Direct-Access TS TS4GUFM-H 1100 PQ: 0 ANSI: 0 CCS [ 4.140067] sd 2:0:0:0: Attached scsi generic sg0 type 0 [ 4.140590] sd 2:0:0:0: [sda] 8028160 512-byte logical blocks: (4.11 GB/3.82 GiB) [ 4.141597] sd 2:0:0:0: [sda] Write Protect is off [ 4.141618] sd 2:0:0:0: [sda] Mode Sense: 43 00 00 00 [ 4.142974] sd 2:0:0:0: [sda] No Caching mode page present [ 4.143000] sd 2:0:0:0: [sda] Assuming drive cache: write through [ 4.145837] sd 2:0:0:0: [sda] No Caching mode page present [ 4.145858] sd 2:0:0:0: [sda] Assuming drive cache: write through [ 4.147931] sda: sda1 sda2 < sda5 > [ 4.150972] sd 2:0:0:0: [sda] No Caching mode page present [ 4.151001] sd 2:0:0:0: [sda] Assuming drive cache: write through [ 4.151023] sd 2:0:0:0: [sda] Attached SCSI disk [ 4.249168] input: HID 046a:004b as /devices/pci0000:00/0000:00:1d.1/usb3/3-1/3-1:1.0/input/input2 [ 4.249579] generic-usb 0003:046A:004B.0001: input,hidraw0: USB HID v1.11 Keyboard [HID 046a:004b] on usb-0000:00:1d.1-1/input0 [ 4.287805] input: HID 046a:004b as /devices/pci0000:00/0000:00:1d.1/usb3/3-1/3-1:1.1/input/input3 [ 4.289235] generic-usb 0003:046A:004B.0002: input,hidraw1: USB HID v1.11 Mouse [HID 046a:004b] on usb-0000:00:1d.1-1/input1 [ 4.297604] input: EloTouchSystems,Inc Elo TouchSystems 2216 AccuTouch\xffffffc2\xffffffae\xffffffae USB Touchmonitor Interface as /devices/pci0000:00/0000:00:1d.1/usb3/3-2/3-2:1.0/input/input4 [ 4.298913] generic-usb 0003:04E7:0050.0003: input,hidraw2: USB HID v1.00 Pointer [EloTouchSystems,Inc Elo TouchSystems 2216 AccuTouch\xffffffc2\xffffffae\xffffffae USB Touchmonitor Interface] on usb-0000:00:1d.1-2/input0 [ 4.299878] usbcore: registered new interface driver usbhid [ 4.299925] usbhid: USB HID core driver [ 4.352639] EXT4-fs (sda1): INFO: recovery required on readonly filesystem [ 4.352661] EXT4-fs (sda1): write access will be enabled during recovery [ 8.519257] EXT4-fs (sda1): recovery complete [ 8.564389] EXT4-fs (sda1): mounted filesystem with ordered data mode. Opts: (null) [ 14.280922] ADDRCONF(NETDEV_UP): eth0: link is not ready [ 14.280944] ADDRCONF(NETDEV_UP): eth1: link is not ready [ 14.310368] udevd[308]: starting version 175 [ 14.353873] Adding 1045500k swap on /dev/sda5. Priority:-1 extents:1 across:1045500k [ 14.428718] lp: driver loaded but no devices found [ 14.521667] EXT4-fs (sda1): re-mounted. Opts: errors=remount-ro [ 15.073459] [drm] Initialized drm 1.1.0 20060810 [ 15.097073] psb_gfx: module is from the staging directory, the quality is unknown, you have been warned. [ 15.180630] gma500 0000:00:02.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 15.180648] gma500 0000:00:02.0: setting latency timer to 64 [ 15.182117] Stolen memory information [ 15.182127] base in RAM: 0x7f800000 [ 15.182134] size: 7932K, calculated by (GTT RAM base) - (Stolen base), seems wrong [ 15.182143] the correct size should be: 8M(dvmt mode=3) [ 15.234889] Set up 1983 stolen pages starting at 0x7f800000, GTT offset 0K [ 15.235126] [drm] SGX core id = 0x01130000 [ 15.235135] [drm] SGX core rev major = 0x01, minor = 0x02 [ 15.235143] [drm] SGX core rev maintenance = 0x01, designer = 0x00 [ 15.268796] [Firmware Bug]: ACPI: No _BQC method, cannot determine initial brightness [ 15.269888] acpi device:04: registered as cooling_device2 [ 15.270568] acpi device:05: registered as cooling_device3 [ 15.270947] input: Video Bus as /devices/LNXSYSTM:00/device:00/PNP0A08:00/LNXVIDEO:00/input/input5 [ 15.271238] ACPI: Video Device [GFX0] (multi-head: yes rom: no post: no) [ 15.271424] [drm] Supports vblank timestamp caching Rev 1 (10.10.2010). [ 15.271434] [drm] No driver support for vblank timestamp query. [ 15.374694] type=1400 audit(1349363644.167:2): apparmor="STATUS" operation="profile_load" name="/sbin/dhclient" pid=435 comm="apparmor_parser" [ 15.385518] type=1400 audit(1349363644.179:3): apparmor="STATUS" operation="profile_load" name="/usr/lib/NetworkManager/nm-dhcp-client.action" pid=435 comm="apparmor_parser" [ 15.386369] type=1400 audit(1349363644.179:4): apparmor="STATUS" operation="profile_load" name="/usr/lib/connman/scripts/dhclient-script" pid=435 comm="apparmor_parser" [ 15.677514] r8169 0000:01:00.0: eth0: link down [ 15.694828] ADDRCONF(NETDEV_UP): eth0: link is not ready [ 16.537490] gma500 0000:00:02.0: allocated 800x480 fb [ 16.558066] fbcon: psbfb (fb0) is primary device [ 16.747122] gma500 0000:00:02.0: BL bug: Reg 00000000 save 00000000 [ 16.775550] Console: switching to colour frame buffer device 100x30 [ 16.781804] fb0: psbfb frame buffer device [ 16.781812] drm: registered panic notifier [ 16.870168] [drm] Initialized gma500 1.0.0 2011-06-06 for 0000:00:02.0 on minor 0 [ 16.871166] snd_hda_intel 0000:00:1b.0: power state changed by ACPI to D0 [ 16.871186] snd_hda_intel 0000:00:1b.0: power state changed by ACPI to D0 [ 16.871207] snd_hda_intel 0000:00:1b.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 16.871284] snd_hda_intel 0000:00:1b.0: setting latency timer to 64 [ 29.338953] r8169 0000:01:00.0: eth0: link up [ 29.339471] ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready [ 31.427223] init: failsafe main process (675) killed by TERM signal [ 31.522411] type=1400 audit(1349363660.316:5): apparmor="STATUS" operation="profile_replace" name="/sbin/dhclient" pid=889 comm="apparmor_parser" [ 31.523956] type=1400 audit(1349363660.316:6): apparmor="STATUS" operation="profile_replace" name="/usr/lib/NetworkManager/nm-dhcp-client.action" pid=889 comm="apparmor_parser" [ 31.524882] type=1400 audit(1349363660.320:7): apparmor="STATUS" operation="profile_replace" name="/usr/lib/connman/scripts/dhclient-script" pid=889 comm="apparmor_parser" [ 31.525940] type=1400 audit(1349363660.320:8): apparmor="STATUS" operation="profile_load" name="/usr/sbin/tcpdump" pid=891 comm="apparmor_parser" [ 34.526445] postgres (1003): /proc/1003/oom_adj is deprecated, please use /proc/1003/oom_score_adj instead. [ 40.144048] eth0: no IPv6 routers present

    Read the article

  • Issue in setting up VPN connection (IKEv1) using android (ICS vpn client) with Strongswan 4.5.0 server

    - by Kushagra Bhatnagar
    I am facing issues in setting up VPN connection(IKEv1) using android (ICS vpn client) and Strongswan 4.5.0 server. Below is the set up: Strongswan server is running on ubuntu linux machine which is connected to some wifi hotspot. Using the steps in this guide link, I generated CA, server and client certificate. Once certificates are generated, following (clientCert.p12 and caCert.pem) are sent to mobile via mail and installed on android device. Below are the ip addresses assigned to various interfaces Linux server wlan0 interface ip where server is running: 192.168.43.212, android device eth0 interface ip address: 192.168.43.62; Android device is also attached with the same wifi hotspot. On the Android device, I uses IPsec Xauth RSA option for setting up VPN authentication configuration. I am using the following ipsec.conf configuration: # basic configuration config setup plutodebug=all # crlcheckinterval=600 # strictcrlpolicy=yes # cachecrls=yes nat_traversal=yes # charonstart=yes plutostart=yes # Add connections here. # Sample VPN connections conn ios1 keyexchange=ikev1 authby=xauthrsasig xauth=server left=%defaultroute leftsubnet=0.0.0.0/0 leftfirewall=yes leftcert=serverCert.pem right=192.168.43.62 rightsubnet=10.0.0.0/24 rightsourceip=10.0.0.2 rightcert=clientCert.pem pfs=no auto=add      With the above configurations when I enable VPN on android device, VPN connection is not successful and it gets timed out in Authentication phase. I ran wireshark on both the android device and strongswan server, from the tcpdump below are the observations. Initially Identity Protection (Main mode) exchanges happens between device and server and all are successful. After all successful Identity Protection (Main mode) exchanges server is sending Transaction (Config mode) to device. In reply android device is sending Informational message instead of Transaction (Config mode) message. Further server is keep on sending Transaction (Config mode) message and device is again sending Identity Protection (Main mode) messages. Finally timeout happens and connection fails. I also capture Strongswan server logs and below are the snippets from the server logs which also verifies the same(described above). Apr 27 21:09:40 Linux pluto[12105]: | **parse ISAKMP Message: Apr 27 21:09:40 Linux pluto[12105]: | initiator cookie: Apr 27 21:09:40 Linux pluto[12105]: | 06 fd 61 b8 86 82 df ed Apr 27 21:09:40 Linux pluto[12105]: | responder cookie: Apr 27 21:09:40 Linux pluto[12105]: | 73 7a af 76 74 f0 39 8b Apr 27 21:09:40 Linux pluto[12105]: | next payload type: ISAKMP_NEXT_HASH Apr 27 21:09:40 Linux pluto[12105]: | ISAKMP version: ISAKMP Version 1.0 Apr 27 21:09:40 Linux pluto[12105]: | exchange type: ISAKMP_XCHG_INFO Apr 27 21:09:40 Linux pluto[12105]: | flags: ISAKMP_FLAG_ENCRYPTION Apr 27 21:09:40 Linux pluto[12105]: | message ID: a2 80 ad 82 Apr 27 21:09:40 Linux pluto[12105]: | length: 92 Apr 27 21:09:40 Linux pluto[12105]: | ICOOKIE: 06 fd 61 b8 86 82 df ed Apr 27 21:09:40 Linux pluto[12105]: | RCOOKIE: 73 7a af 76 74 f0 39 8b Apr 27 21:09:40 Linux pluto[12105]: | peer: c0 a8 2b 3e Apr 27 21:09:40 Linux pluto[12105]: | state hash entry 25 Apr 27 21:09:40 Linux pluto[12105]: | state object not found Apr 27 21:09:40 Linux pluto[12105]: packet from 192.168.43.62:500: Informational Exchange is for an unknown (expired?) SA Apr 27 21:09:40 Linux pluto[12105]: | next event EVENT_RETRANSMIT in 10 seconds for #9 Can anyone please provide update on this issue. Why the VPN connection gets timed out and why the ISAKMP exchanges are not proper between Android and strongswan server.

    Read the article

  • Empathy sametime client id

    - by user91860
    I have been using Pidgin as an all-in-one IM client, but now as Empathy is the default app in Ubuntu I wanted to try it out. I have a sametime account at an external company that is keen to restrict access to their service from certain sametime client versions only. I was able to trick it with pidgin by specifying the following settings in accounts.xml: <setting name='client_minor' type='int'>8510</setting> <setting name='client_major' type='int'>30</setting> <setting name='client_id_val' type='int'>4876</setting> I tried to do the same in Empathy but I failed. As far as I know, Pidgin and Empathy use the same connector Plugin for sametime, so basically the functions should be there somewhere but there is little information about the configuration files and that doesn't discuss any sametime specific options.

    Read the article

  • What does the BIOS setting XHCI Pre-Boot Mode do?

    - by Jamie Kitson
    I have a BIOS setting called XHCI Pre-Boot Mode. If I have this enabled USB devices which aren't plugged in at boot are never recognised, if I set it to Disabled then USB devices work normally. The brief BIOS description says "Enable this option if you need USB3.0 support in DOS." Which I don't, but it also says "Please note that XHCI controller will be disabled if you set this item as Disabled." So does that mean that USB3 is disabled with this option? Here's a picture of the screen: http://www.flickr.com/photos/jamiekitson/8017563004/

    Read the article

  • Does the nginx “upstream” directive have a port setting?

    - by user55467
    moved from:http://stackoverflow.com/questions/3748517/does-nginx-upstream-has-a-port-setting I use upstream and proxy for load balancing. The directive proxy_pass http://upstream_name uses the default port, which is 80. However, if the upstream server does not listen on this port, then the request fails. How do I specify an alternate port? my configuration: http{ #... upstream myups{ server 192.168.1.100:6666; server 192.168.1.101:9999; } #.... server{ listen 81; #..... location ~ /myapp { proxy_pass http://myups:81/; } } nginx -t: [warn]: upstream "myups" may not have port 81 in /opt/nginx/conf/nginx.conf:78.

    Read the article

  • MacBook Pro 15in High-res hard to read. What setting should I change?

    - by orokusaki
    I just bought a new MacBook Pro with the high-res screen (1680x1050), but I noticed that all text is so small that to read it my face has to be like 18 inches away. When I adjusted the resolution to be the next sizes down (1440 x 852, and 1440 x 852 stretched), as well as all the other smaller sizes it made everything look blurry (similarly to when you use Command + Scroll to zoom in, how the text is really soft on the edges, and difficult to read). Is there a setting somewhere that I'm missing, or another resolution settings area that I can use. I feel like this 2800 dollar notebook may be only good for movie watching otherwise. Thanks in advance.

    Read the article

  • Is there a serious issue with setting the SUID bit on tcpdump?

    - by Dean
    I'm running tcpdump on a remote machine, and piping the output to Wireshark on my local machine over SSH. In order to do this, I had to set the SUID bit on tcpdump. For background, the remote machine is an Amazon EC2 running "Amazon Linux AMI 2012.09". On this image, there is no root password, and it is not possible to log in as root. You can't use sudo without a TTY, and therefore you have to set the SUID. What are the practical risks of setting this bit on tcpdump? Is there any need to be paranoid? Should I unset it whenever I'm not capturing?

    Read the article

  • How to stop jucheck from running? Java won't remember "Check for Updates Automatically" setting.

    - by Ken
    I've installed Java on Windows Vista, and every day I get a Vista security warning asking me if I want to run "jucheck". Apparently this is the Java automatic updater. Well, I don't want it to run on its own, ever. I cancel it, and quit it. I right-click on the taskbar and unclick "Check for Updates Automatically", and then click "Never Check", and "Apply". And yet, it never remembers this setting. If I come back to the "Java Control Panel" right after clicking "OK", the very same box is checked again, all on its own. Is there some way to kill jucheck once and for all? If I simply delete jucheck.exe, will Java (other than the automatic check) still work, and will manual updates still work, and will it stop even trying to update every morning?

    Read the article

  • What is a preferred method for automatically configuring and setting up an Ubuntu instance?

    - by sutch
    I am tired of manually configuring instances of Ubuntu for testing web applications and for setting up workstations. I'm even more frustrated by the issues caused by inconsistent configurations. Is there a method (hopefully not too time consuming to learn and setup) that allows for automation of the setup and configuration of an Ubuntu server or workstation from an ISO. This is primarily for virtual machine instances, but it would be helpful to also create instances on hardware. I am specifically looking for a method to automate the installation of libraries (apt-get), configure services (such as Apache and MySQL), add 3rd party software (download, extract and build), and add libraries to scripting languages (for example, Ruby Gems or CPAN packages for Perl).

    Read the article

  • How do you stop Linux from re-setting the display brightness?

    - by Shawn J. Goff
    After manually setting the display brightness on my laptop, the system re-sets the value. If the laptop is plugged in, the value is set to full brightness; if it is not plugged in, it is set to dimmer. How do I stop that behavior? Note that I am not talking about what it does in response to the event of plugging in or unplugging my system. It changes on it's own - usually several minutes after I change the brightness value. I have observed this behavior on different systems, different distributions, and different desktop environments.

    Read the article

  • Can't boot into XP after setting up dual boot with Win 7 vhd.

    - by bebop
    I set up a dual boot for win 7 from vhd on 2 xp machines. One of them everything went fine, and I get the option to choose the os when I turn the machine on. The other was slightly different in that rather than seeing the current OS disk (the one with XP on) as the c:\ when I was setting up windows 7 vhd during install it saw the disk as d:. I didn't think anything of it and went ahead and created a vhd on the d: drive. Now when I turn this machine on, it boots straight to win7 and I never get the option to choose xp. When I look at the boot option in msconfig, I only see Windows 7. How can I go about adding the old XP drive as a boot option at startup again? Edit: Strangely when I rebooted this time (perhaps the first time since I removed the install DVD) it boots to XP. I suppose I'll just have to reinstall windows 7 again in a new vhd...

    Read the article

  • What is the pixel clock setting on my monitor actually doing?

    - by codecowboy
    I am experiencing display interference on a dell 24" flat panel monitor.I find that if I adjust the pixel clock settings up or down in the monitor's on-screen menus, the interference goes away for a while. The monitor is attached to a Macbook Pro using a mini display to VGA adapter. I have found that in a different house, I get the interference problem less so it might be related to electricity supply or possibly even ethernet powerline (total guess). What does the pixel clock setting actually do and does this behaviour point to a likely cause of the interference?

    Read the article

  • Any good resources on setting up an ubuntu virtual machine for web development?

    - by Relequestual
    I'm currently on my placement year at uni with 4 months left. Before working at my current place, I have not used a nix environment for web development and have used WAMP. Over the past year I have found some very interesting new tech that requires a bit more than my shared hosting even to play with (eg node.js, RoR 3). At work we use a Virtual Machine for development, but that's all been set up and configured to match the live servers, and is managed with a Puppet server. Are there any really good resources for setting up and configuring an Ubuntu VM as a web server? Work currently uses Ubuntu so I would assume this is a good OS to use. I do of course know how to use google, but the noise ratio is just too big, so thought I'd ask here, as I know many of you will have a ton of bookmarks. Cheers.

    Read the article

  • I'll be setting up a dedicated web server at work soon, my first non hobby server - What should I know?

    - by Rogue Coder
    I've been running my own dedicated server running CentOS and a LAMP stack for 2-3 years now, but it's only been hosting my own websites which aren't super important. However, I will soon be setting up a Linux Webserver and Linux Database Server at work, and I'm wondering what are some important things I should be doing. It's an internal server only, so only people in the company can access it. Should I get a slave server for both of my servers for backups? If I do this, how many backups should I be keeping and how often should those backups be done? Right now on my current server I run a cron job nightly to backup my MySQL databases (Usually 40mb files once compressed), and bi-weekly cron jobs to backup my web root. I just store these files on my local computer via FTP. Also, for an internal server like this, should I look at using LightHTTPD or NginX to increase performance, or will Apache be fine?

    Read the article

  • Setting up a copy of a site with IIS 7?

    - by SJaguar13
    I have a site running on IIS with a dyndns.org domain that points to the IP of the Windows 2008 machine hosting it. I need a copy of that site for development purposes. I set up another folder with all the files, and create a new site in IIS. I don't really have a domain for it, so I was just going to use the IP address. When I go to localhost, 127.0.0.1, or the internal IP, I get bad hostname. If I use the IP address on port 80 (the same as the real version of the site), I get 404 not found. If I use a different port so I don't have them both on the same IP with the same port, I get connection timed out. How do I go about setting this up?

    Read the article

  • Setting up a server with only subdomains, any connection to top level goes to main server on another IP?

    - by Anagio
    I'm developing a web app where users will have their own sub-domain to login to and use the application. I'm running wordpress for the main website to manage the public / front end. Our application is developed in zend framework. The zf project is currently in a subfolder on the main server. I'd like to place the zend framework project onto another server (different IP) and keep it separate from the the wordpress front end www.domain.com site. The zf application server will run nginx. I'm not sure how to setup a server to run strictly sub domains. Setting up the virtual hosts in the configuration file is no problem. To give the users username.domain.com. But what about the main default configuration file? How would that be configured since the top level domain is technically another server (wordpress) on another IP?

    Read the article

  • Varnish cache and PHP session; setting header?

    - by StCee
    Varnish by default would not cache page with cookies. I read on some posts that one workaround for PHP pages is to set header('Cache-Control: public, s-maxage=60'); in php pages. But would it makes Varnish cache the page with the session cookie? Session is started on that page, and although there is nothing personal on that page, I would still want the session to persist in case the user would do something private later. So is there a way to cache the page without the session cookie? And still be able to pass session between pages? I can imagine some sort of weird solution with hidden form, but I would prefer if it can be done with VCL configuration or header setting. Thanks a lot!

    Read the article

  • How to write an autohotkey script to toggle the Show hidden files and folders setting?

    - by Oq
    I would like to make use of a hotkey to toggle the Show hidden files and folders setting. I want to use it on both windowsXp and Windows7. Here is what I got so far: #h:: RegRead, Showall_Status, HKEY_LOCAL_MACHINE, Software\Microsoft\Windows\CurrentVersion\Explorer\Advanced\Folder\Hidden\SHOWALL, CheckedValue, If Showall_Status = 0 RegWrite, REG_DWORD, HKEY_LOCAL_MACHINE, Software\Microsoft\Windows\CurrentVersion\Explorer\Advanced\Folder\Hidden\SHOWALL, CheckedValue, 1 Else RegWrite, REG_DWORD, HKEY_LOCAL_MACHINE, Software\Microsoft\Windows\CurrentVersion\Explorer\Advanced\Folder\Hidden\SHOWALL, CheckedValue, 0 Return Problem is when I run the script it simply does nothing. Not sure what I am missing.

    Read the article

< Previous Page | 69 70 71 72 73 74 75 76 77 78 79 80  | Next Page >