  • The machine-default permission settings do not grant Local Activation permission for the COM Server

    - by subash
    when i was trying to visit my webapplication(developed in asp.net & c#.net) in internet explorer ,i was not able to see the page. when i went event viewer the events ocurred,it was showing the error as below " The machine-default permission settings do not grant Local Activation permission for the COM Server application with CLSID {BC866CF2-5486-41F7-B46B-9AA49CF3EBB1} to the user SAAD-DEV9\ASPNET SID (S-1-5-21-1757981266-1644491937-839522115-1007). This security permission can be modified using the Component Services administrative tool. " how to overcome this and see my application page

    Read the article

  • .apk signing fails even with Sun JDK (java.lang.NoClassDefFoundError: com.android.jarutils.DebugKeyP

    - by ianweller
    I'm having an interesting problem signing my Android application, whether or not I'm using a debug key. Regardless of the JDK I have installed to /usr/bin/{java,keytool,jarsigner} (OpenJDK or Sun's JDK) it will always give the following output after compiling successfully: -package-debug-sign: [apkbuilder] Creating RemoteNotify-debug-unaligned.apk and signing it with a debug key... BUILD FAILED /home/ianweller/AndroidSDK/platforms/android-7/templates/android_rules.xml:281: The following error occurred while executing this line: /home/ianweller/AndroidSDK/platforms/android-7/templates/android_rules.xml:152: java.lang.NoClassDefFoundError: com.android.jarutils.DebugKeyProvider The application was built and signed just fine by Eclipse with the ADT plugin (even without Sun's JDK installed). I'm on Fedora 12. I'm wanting to get my code out of Eclipse and move it into a git repository, but being unable to build it from ant will not allow this to happen.

    Read the article

  • Retrieving search results from Google, Google Images, Wikipedia, Flickr, Dictionary.com

    - by Arjun Vasudevan
    I've an ASP.NET page with a textbox and a option from user of the following choices: Wikipedia, Google, Dictionary.com, Flickr, Google images. The user enters a word(s) in the textbox and selects a choice among the following. Depending on the choice select by the user I wish to return the following. Wikipedia: Return the content and link to the page corresponding to the topic about the word. Google: Return the top 10 results of google search for this word. Flickr: Return a few images atmost 10 images from flickr search GoogleImage: Return a few images from google image search. Dictionary: Return the meaning of the word. How can I do that? Which tool box control can I use for holding the results coming from these sites?

    Read the article

  • Unregistering a COM wrapped .NET assembly

    - by flopdix
    I created a COM exposed .NET 2.0 dll and registered with my windows operating system using 'regasm' and 'gacutil' (in GAC). Then I tried to call this component from my classic ASP page. It worked fine. But, I need to change the functionality of my assembly. I unregistered it again using 'regasm' and 'gacutil' (from GAC) utilities and copied my new .NET DLL and registered again (This time using a new version of the DLL). For some reason, i still have a pointer to my old assembly and new calls to the DLL from ASP page are not working. Any Ideas on what process i need to follow to ensure that all the references to the old version are completely removed? I appreciate any help.

    Read the article

  • redirecting to multiple virtual subdomains using htaccess

    - by Gerald Ferreira
    Hi Everyone I am trying to create subdomains via htaccess. The code below does exactly want I want It takes http://domain.com and redirect it to http://www.domain.com Options -Indexes DirectoryIndex index.html index.htm index.asp index.php ErrorDocument 401 http://www.domain.com ErrorDocument 403 http://www.domain.com ErrorDocument 404 http://www.domain.com ErrorDocument 500 http://www.domain.com ErrorDocument 507 http://www.domain.com RewriteEngine On RewriteCond %{HTTP_HOST} ^domain.com$ RewriteRule ^(.*) http://www.domain.com/$1 [QSA,L,R=301] AddType text/html .html .htm .asp This is the part I am not to sure of: RewriteCond %{HTTP_HOST} ^domain.com/nl$ RewriteRule ^(.*) http://nl.domain.com/$1 [QSA,L,R=301] How can I create virtual subdomains so that if someone goes to http://nl.domain.com it would stay on http://nl.domain.com if someone types http://www.nl.domain.com it would take out the http://www.nl.domain.com and make it http://nl.domain.com also the directory structure for the subdomain would be http://www.domain.com/nl (This is where the actual files will be sitting). so if someone goes to http://www.domain.com/nl it should also redirect to http://nl.domain.com. Thanks in advance for any advice and pointers

    Read the article

  • Mac OS X: java.lang.ClassNotFoundException: com.sun.java.browser.plugin2.DOM

    - by Thilo
    I am trying to use the new LiveConnect features introduced in Java 6 Update 10. Code looks like this (copied from the applet tutorial): Class<?> c = Class.forName("com.sun.java.browser.plugin2.DOM"); Method m = c.getMethod("getDocument", java.applet.Applet.class); Document document = (Document) m.invoke(null, this); But all I am getting is a ClassNotFoundException for the entry-point class. This on the Mac, 10.6, with both Firefox and Safari. Java Plug-in 1.6.0_22 Using JRE version 1.6.0_22-b04-307-10M3261 Java HotSpot(TM) 64-Bit Server VM Is this not implemented on the Mac? Or do I need to configure something? All I need to do is get and set the value of form elements on the page, so I would be fine with an older (pre-6u10) API if that works better.

    Read the article

  • Automate open dialog in C#? (From COM OCX)

    - by JL
    I have a COM OCX control that I need to automate. It has a method called Open() this method is called without parameters, and always displays an open file dialog (standard one with windows). Is there a way for me to somehow get the file open dialog to open a file I specify , then close the dialog? I would also not like to use sendkeys or any other variants, because I require the solution to be reliable. So ideally would like to grab a handle on that window, and set the file name programatically, and then execute the open method programatically. Thanks in advance.

    Read the article

  • gametutorials.com questions and reviews DirectX tutorials

    - by numerical25
    Just curious to know if anyone has ever used gametutorials.com products for learning directX. I was debating on whether I should buy it or not. I read online that most of his tutorials were written in the source code. It's nice to heavily comment your code but if most of the tutorial is in his code then I don't think that is necessarily the best way to do a tutorial. But anyhow, I am not sure about that, I am just checking for clarification. and checking to see if it would be a good investment.

    Read the article

  • do not use com.sun.xml.internal.*?

    - by sarah xia
    Hi all, Is this statement true: com.sun.xml.internal package is an internal package as the name suggestes. Users should not write code that depends on internal JDK implementation classes. Such classes are internal implementation details of the JDK and subject to change without notice One of my colleagues used one of the classes in his code, which caused javac task in Ant fail to compile our project as the compiler couldn't find the class. Answer from Sun/Oracle says that this is expected behavior of the compiler as user shouldn't use the package. Question is why the classes in the package made public in the first place? Thanks, Sarah

    Read the article

  • Hosted SVN - RepositoryHosting.com

    - by SVN User
    I'm currently reviewing repositoryhosting.com for possibly hosting our company code, however, I'm weary about pushing forward for a few reasons. First, if the company goes under, I have no assurance that I will have access to grab backups of the code prior. Secondly, their terms state this: "User agrees that Repository Hosting shall not be liable for any direct, indirect, incidental, special, consequential or exemplary damages, including but not limited to, damages for loss of profits, goodwill, use, data or other intangible losses resulting from the use of or inability to use the Service." Basically, I want to ensure that our data is safe. I understand that they do offsite backups and such, however, if there were to be a catastrophic loss of data that was their fault, would we be left with just a "sorry"? What about your thoughts on hosted svn and is it better to just continue to do it yourself?

    Read the article

  • Error openin microsoft.com with google chrome

    - by Ilnur
    Hi! I need help with my browsers. In my OS (windows 7 basic) installed 2 browsers: IE 8 and Google Chrome. When I trying to open pages, which associated with microsoft.com (like ms live and others), my browser crashes. IE 8 crashes too. But Opera (I've installed it later) works fine with that pages. P.S. I tried to search the trojan software and viruses. But my PC is clean.

    Read the article

  • C# Image.Clone to byte[] causes EDIT.COM to open on Windows XP

    - by JayDial
    It appears that cloning a Image and converting it to a byte array is causing EDIT.COM to open up on Windows XP machines. This does not happen on a Windows 7 machine. The application is a C# .NET 2.0 application. Does anyone have any idea why this may be happening? Here is my Image conversion code: public static byte[] CovertImageToByteArray(Image imageToConvert) { imageToConvert.Clone() as Image; if(clone == null) return null; imageToConvert.Dispose(); byte[] imageByteArray; using (MemoryStream ms = new MemoryStream()) { clone.Save(ms, clone.RawFormat); imageByteArray = ms.ToArray(); } return imageByteArray; } public static Image ConvertByteArrayToImage(byte[] imageByteArray, ImageFormat formatOfImage) { Image image; using ( MemoryStream ms = new MemoryStream(imageByteArray, 0, imageByteArray.Length)) { ms.Write(imageByteArray, 0, imageByteArray.Length); image = Image.FromStream(ms, true); } return image; } Thanks Justin

    Read the article

  • GMail detecting mail as spam

    - by Petru Toader
    I've been trying for a long time to get our company's mail server send mail that will get accepted by the GMail spam filter. I have managed making it work for Yahoo Mail and Hotmail, sadly GMail is still marking our mails as spam. I have configured DKIM, SPF, DMARC and verified our mail server IP address against blacklists. I also have pasted here the headers GMail gets when we send a mail. Delivered-To: gmail-test-account@gmail.com Received: by 10.42.215.6 with SMTP id hc6csp107427icb; Wed, 20 Aug 2014 07:34:26 -0700 (PDT) X-Received: by 10.194.100.34 with SMTP id ev2mr59101019wjb.76.1408545265402; Wed, 20 Aug 2014 07:34:25 -0700 (PDT) Return-Path: <[email protected]> Received: from mail.phyramid.com (mail.phyramid.com. [178.157.82.23]) by mx.google.com with ESMTPS id dj10si4827754wib.79.2014.08.20.07.34.24 for <[email protected]> (version=TLSv1.1 cipher=ECDHE-RSA-RC4-SHA bits=128/128); Wed, 20 Aug 2014 07:34:25 -0700 (PDT) Received-SPF: pass (google.com: domain of company@phyramid.com designates 178.157.82.23 as permitted sender) client-ip=178.157.82.23; Authentication-Results: mx.google.com; spf=pass (google.com: domain of company@phyramid.com designates 178.157.82.23 as permitted sender) [email protected]; dkim=pass header.i=@phyramid.com Received: from localhost (localhost [127.0.0.1]) by mail.phyramid.com (Postfix) with ESMTP id ED2BB2017AC for <[email protected]>; Wed, 20 Aug 2014 17:33:23 +0300 (EEST) DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/simple; d=phyramid.com; h= content-type:content-type:mime-version:x-mailer:subject:subject :message-id:to:from:from:date:date; s=dkim; t=1408545197; x= 1409409197; bh=e04RtoyF7G39lfCvA9LLhTz4nF64siZtN5IYmC18Xsc=; b=o +6mO8Uz4Uf1G4U2q6tKUiEy2N2n/5R2VtPPwIvBE5xzK/hEd2sDGMxVzQVgIDCsK Q0Xh+auPaQpxldQ+AEcL2XSZMrk/g0mJONjkpI19I5AwGIJCR1SVvxdecohTn9iR bCHzrGi2wAicfDBzOH6lUBNfh2thri79aubdCYc97U= X-Amavis-Modified: Mail body modified (using disclaimer) - mail.phyramid.com X-Virus-Scanned: Debian amavisd-new at mail.phyramid.com Received: from mail.phyramid.com ([127.0.0.1]) by localhost (mail.phyramid.com [127.0.0.1]) (amavisd-new, port 10024) with ESMTP id 3JcgXZAXeFtX for <[email protected]>; Wed, 20 Aug 2014 17:33:17 +0300 (EEST) Received: from whiterock.local (unknown [109.98.21.30]) by mail.phyramid.com (Postfix) with ESMTPSA id 05CAE200280 for <[email protected]>; Wed, 20 Aug 2014 17:33:15 +0300 (EEST) Date: Wed, 20 Aug 2014 17:34:15 +0300 From: Company Mail <[email protected]> To: gmail-test-account@gmail.com Message-ID: <[email protected]> Subject: hey there! X-Mailer: Airmail (247) MIME-Version: 1.0 Content-Type: text/plain; charset="utf-8" Content-Transfer-Encoding: 7bit Content-Disposition: inline How was your summer? ---- Thanks a lot!

    Read the article

  • How do the major C# DI/IoC frameworks compare?

    - by Slomojo
    At the risk of stepping into holy war territory, What are the strengths and weaknesses of these popular DI/IoC frameworks, and could one easily be considered the best? ..: Ninject Unity Castle.Windsor Autofac StructureMap Are there any other DI/IoC Frameworks for C# that I haven't listed here? In context of my use case, I'm building a client WPF app, and a WCF/SQL services infrastructure, ease of use (especially in terms of clear and concise syntax), consistent documentation, good community support and performance are all important factors in my choice. Update: The resources and duplicate questions cited appear to be out of date, can someone with knowledge of all these frameworks come forward and provide some real insight? I realise that most opinion on this subject is likely to be biased, but I am hoping that someone has taken the time to study all these frameworks and have at least a generally objective comparison. I am quite willing to make my own investigations if this hasn't been done before, but I assumed this was something at least a few people had done already. Second Update: If you do have experience with more than one DI/IoC container, please rank and summarise the pros and cons of those, thank you. This isn't an exercise in discovering all the obscure little containers that people have made, I'm looking for comparisons between the popular (and active) frameworks.

    Read the article

  • Getting all pdf files from a domain (for example *.adomain.com)

    - by Zack
    I need to download all pdf files from a certain domain. There are about 6000 pdf on that domain and most of them don't have an html link (either they have removed the link or they never put one in the first place). I know there are about 6000 files because I'm googling: filetype:pdf site:*.adomain.com However, Google lists only the first 1000 results. I believe there are two ways to achieve this: a) Use Google. However, how I can get all 6000 results from Google? Maybe a scraper? (tried scroogle, no luck) b) Skip Google and search directly on domain for pdf files. How do I do that when most them are not linked?

    Read the article

  • getting usb com port

    - by I__
    i have this function: private string GetUSBComPort() { string[] sPorts = SerialPort.GetPortNames(); foreach (string port in sPorts) { if (port != "COM1" && port != "COM4") { return port; } } return null; } this function is being called from form load: private void Form1_Load(object sender, EventArgs e) { serialPort1 = new SerialPort(GetUSBComPort()); if (serialPort1.IsOpen) { serialPort1.Close(); } serialPort1.Open(); //ThreadStart myThreadDelegate = new ThreadStart(ReceiveAndOutput); //Thread myThread = new Thread(myThreadDelegate); //myThread.Start(); this.serialPort1.DataReceived += new SerialDataReceivedEventHandler(sp_DataReceived); } the function is unfortunately returning null how do i get the com port to which my phone is attached to via USB?

    Read the article

  • Server currently under DDOS, not sure what to do

    - by Volex
    My web server is currently under a DDOS attack I believe, the messages log is full of these kind of messages: May 13 15:51:19 kernel: nf_conntrack: table full, dropping packet. May 13 15:51:19 last message repeated 9 times May 13 15:51:24 kernel: __ratelimit: 78 callbacks suppressed May 13 15:51:24 kernel: nf_conntrack: table full, dropping packet. May 13 15:52:06 kernel: possible SYN flooding on port 80. Sending cookies. and a netstat has a huge amount of the following: tcp 0 0 my.host.com:http bb176da0.virtua.com.br:4998 SYN_RECV tcp 0 0 my.host.com:http 187.0.43.109:2694 SYN_RECV tcp 0 0 my.host.com:http 109.229.4.145:1722 SYN_RECV tcp 0 0 my.host.com:http 189-84-163-244.sodobr:63267 SYN_RECV tcp 0 0 my.host.com:http bd66839d.virtua.com.br:3469 SYN_RECV tcp 0 0 my.host.com:http 69.101.56.190.dsl.int:52552 SYN_RECV tcp 0 0 my.host.com:http pc-62-230-47-190.cm.vt:2262 SYN_RECV tcp 0 0 my.host.com:http 189-84-163-244.sodobr:63418 SYN_RECV tcp 0 0 my.host.com:http pc-62-230-47-190.cm.vt:1741 SYN_RECV tcp 0 0 my.host.com:http zaq3d739320.zaq.ne.jp:2141 SYN_RECV tcp 0 0 my.host.com:http netacc-gpn-4-80-73.po:52676 SYN_RECV tcpdump shows: 7:11:08.564510 IP 187-4-1xx-4.xxx.ipd.brasiltelecom.net.br.54821 > my.host.com.http: S 999692166:999692166(0) win 65535 <mss 1452,nop,nop,sackOK> 17:11:08.566347 IP 114-44-171-67.dynamic.hinet.net.1129 > my.host.com.http: S 605369055:605369055(0) win 65535 <mss 1440,nop,nop,sackOK> 17:11:08.570210 IP 200-101-13-130.pvoce300.ipd.brasiltelecom.net.br.5590 > my.host.com.http: S 2813379182:2813379182(0) win 16384 <mss 1460,nop,nop,sackOK> 17:11:08.571290 IP dsl-189-143-30-99-dyn.prod-infinitum.com.mx.1615 > my.host.com.http: S 281542700:281542700(0) win 65535 <mss 1452,nop,nop,sackOK> 17:11:08.583847 IP dsl-189-143-30-99-dyn.prod-infinitum.com.mx.1617 > my.host.com.http: S 499413892:499413892(0) win 65535 <mss 1452,nop,nop,sackOK> 17:11:08.588680 IP 170.51.229.112.2569 > my.host.com.http: S 2195084898:2195084898(0) win 65535 <mss 1460,nop,nop,sackOK> 17:11:08.588773 IP gw2-1.211.ru.3180 > my.host.com.http: F 2315901786:2315901786(0) ack 2620913033 win 64240 17:11:08.590656 IP 200-101-13-130.pvoce300.ipd.brasiltelecom.net.br.5614 > my.host.com.http: S 2813715032:2813715032(0) win 16384 <mss 1460,nop,nop,sackOK> 17:11:08.591212 IP 203.82.82.54.15848 > my.host.com.http: S 4070423507:4070423507(0) win 16384 <mss 1400,nop,nop,sackOK> 17:11:08.591254 IP 203.82.82.54.2545 > my.host.com.http: S 1790910784:1790910784(0) win 16384 <mss 1400,nop,nop,sackOK> 17:11:08.591289 IP 203.82.82.54.28306 > my.host.com.http: S 578615626:578615626(0) win 16384 <mss 1400,nop,nop,sackOK> 17:11:08.591591 IP gw2-1.211.ru.3191 > my.host.com.http: F 2316435991:2316435991(0) ack 2634205972 win 64240 17:11:08.591790 IP 200-101-13-130.pvoce300.ipd.brasiltelecom.net.br.5593 > my.host.com.http: S 2813659017:2813659017(0) win 16384 <mss 1460,nop,nop,sackOK> 17:11:08.593691 IP gw2-1.211.ru.3203 > my.host.com.http: F 2316834420:2316834420(0) ack 2629074987 win 64240 I'm not sure what I can do to limit/mitigate this, currently no webpages are being served, any help gratefully appreciated.

    Read the article

  • Calling Matlab's MLApp.MLAppClass.FEval from F#

    - by Matthew
    Matlab provides a COM interface that supports remote execution of arbitrary functions (and code snippets). In particular, it has an Feval method that calls a given Matlab function. The third parameter to this method, pvarArgOut, has COM type VARIANT*, and appears in the Visual Studio F# editor as an argument of type: pvarArgOut: byref<obj> The following code calls interp1, which in Matlab returns a matrix (i.e. 2D double array) result, as is normal for most Matlab functions. let matlab = new MLApp.MLAppClass() let vector_to_array2d (v : vector) = Array2D.init v.Length 1 (fun i j -> v.[i]) let interp1 (xs : vector) (ys : vector) (xi : vector) = let yi : obj = new obj() matlab.Feval("interp1", 1, ref yi, vector_to_array2d xs, vector_to_array2d ys, vector_to_array2d xi) yi :?> float[,] This code compiles fine, but when calling interp1, I get a COM exception: A first chance exception of type 'System.Reflection.TargetInvocationException' occurred in mscorlib.dll A first chance exception of type 'System.Runtime.InteropServices.COMException' occurred in mscorlib.dll An unhandled exception of type 'System.Runtime.InteropServices.COMException' occurred in mscorlib.dll Additional information: Invalid callee. (Exception from HRESULT: 0x80020010 (DISP_E_BADCALLEE)) I get the same error whether initialize yi with a new obj, a new Array2D, or null. How does F# translate VARIANT output arguments?

    Read the article

  • Cast exception when trying to create new Task Schedueler task.

    - by seaneshbaugh
    I'm attempting to create a new task in the Windows Task Scheduler in C#. What I've got so far is pretty much a copy and paste of http://bartdesmet.net/blogs/bart/archive/2008/02/23/calling-the-task-scheduler-in-windows-vista-and-windows-server-2008-from-managed-code.aspx Everything compiles just fine but come run time I get the following exception: Unable to cast COM object of type 'System.__ComObject' to interface type 'TaskScheduler.ITimeTrigger'. This operation failed because the QueryInterface call on the COM component for the interface with IID '{B45747E0-EBA7-4276-9F29-85C5BB300006}' failed due to the following error: No such interface supported (Exception from HRESULT: 0x80004002 (E_NOINTERFACE)). Here's all the code so you can see what I'm doing here without following the above link. TaskSchedulerClass Scheduler = new TaskSchedulerClass(); Scheduler.Connect(null, null, null, null); ITaskDefinition Task = Scheduler.NewTask(0); Task.RegistrationInfo.Author = "Test Task"; Task.RegistrationInfo.Description = "Just testing this out."; ITimeTrigger Trigger = (ITimeTrigger)Task.Triggers.Create(_TASK_TRIGGER_TYPE2.TASK_TRIGGER_DAILY); Trigger.Id = "TestTrigger"; Trigger.StartBoundary = "2010-05-12T06:15:00"; IShowMessageAction Action = (IShowMessageAction)Task.Actions.Create(_TASK_ACTION_TYPE.TASK_ACTION_SHOW_MESSAGE); Action.Id = "TestAction"; Action.Title = "Test Task"; Action.MessageBody = "This is a test."; ITaskFolder Root = Scheduler.GetFolder("\\"); IRegisteredTask RegisteredTask = Root.RegisterTaskDefinition("Background Backup", Task, (int)_TASK_CREATION.TASK_CREATE_OR_UPDATE, null, null, _TASK_LOGON_TYPE.TASK_LOGON_INTERACTIVE_TOKEN, ""); The line that is throwing the exception is this one ITimeTrigger Trigger = (ITimeTrigger)Task.Triggers.Create(_TASK_TRIGGER_TYPE2.TASK_TRIGGER_DAILY); The exception message kinda makes sense to me, but I'm afraid I don't know enough about COM to really know where to begin with this. Also, I should add that I'm using VS 2010 and I had to set the project to either be for x86 or x64 CPU's instead of the usual "Any CPU" because it kept giving me a BadImageFormatException. I doubt that's related to my current problem, but just in case I thought I might as well mention it.

    Read the article

  • Referencing .NET Assembly in VB6 won't work

    - by dretzlaff17
    I wrote a .net assembly using c# to perform functions that will be used by both managed and unmanaged code. I have a VB6 project that now needs to use the assembly via COM. I created my .net assembly, made sure that ComVisible is set to true and that it is registered for COM interop via project properties. public class MyClass [ComVisible(true)] public string GetResponse() { return "Testing Response" } } I build the assembly and copied the file into a folder. TestInterop.dll I then run a batch file to register the assembly tool to register the object for COM. cd C:\Windows\Microsoft.NET\Framework\v4.0.30319\ regasm "c:\Program Files\TestApp\TestInterop.dll" /tlb:TestInterop.tlb I open a new VB6 application and reference TestInterop.dll In VB6 I write the following code and it compiles. Dim obj as TestInterop.MyClass Set obj = new TestInterop.MyClass Dim strTest as string strTest = obj.GetRespose() When I run the program it errors on the obj.GetResponse() line. Run-time error' -2147024894 (80070002'): Automation error The system cannot find the file specified Also, the intellesense does not work on obj. I had to type the GetResponse method. Is this normal? Does anyone have any clue what could be wrong or what steps I missed. Thanks!

    Read the article

  • Interface Marshalling in Delphi

    - by cemick
    I want to send Interface Ref of IVApplication from Visio Add-in to my other one COM server. But I have Ole exception. Now i do that: Code in Visio Add-in: var IStrm: IStream; hres: HResult; rhglobal: HGLOBAL; VisioAppl: IVApplication; begin hres := CreateStreamOnHGlobal(0, TRUE, IStrm); if Succeeded(hres) then hres := CoMarshalInterface(IStrm, IID_IVApplication, VisioAppl, MSHCTX_LOCAL, 0, MSHLFLAGS_NORMAL); if (Succeeded(hres)) then begin hres := GetHGlobalFromStream(IStrm, rhglobal); IStrm := nil; end; end; After this I create instance of my COM server and pass rhglobal to him. Code of my COM server: procedure (AHGlobal: HGlobal); var VisioAppl: Visio_TLB.IVApplication; iStrm: IStream; hres: HResult; begin iStrm := Nil; VisioAppl:= nil; hres := CreateStreamOnHGlobal(AHGlobal, FALSE, iStrm); if (SUCCEEDED(hres)) then begin hres := CoUnmarshalInterface(iStrm, Visio_TLB.IVApplication, VisioAppl); iStrm := nil; ShowMessage('Result:' + BoolToStr(SUCCEEDED(hres))); <-- result 0 ShowMessage(VisioAppl.ProductName); <---- Error end; end;

    Read the article

  • How do I pass an array of structs (containing std:string or BSTR) from ATL to C#. SafeArray? Varian

    - by Andrew
    Hi, I have an ATL COM object that I am using from C#. The interface currently looks like: interface ICHASCom : IDispatch{ [id(1), helpstring("method Start")] HRESULT Start([in] BSTR name, [out,retval] VARIANT_BOOL* result); ... [id(4), helpstring("method GetCount")] HRESULT GetCount([out,retval] LONG* numPorts); ... [id(7), helpstring("method EnableLogging")] HRESULT EnableLogging([in] VARIANT_BOOL enableLogging); }; That is, it's a very simple interface. I also have some events that I send back too. Now, I would like to add something to the interface. In the ATL I have some results, which are currently structs and look like struct REPORT_LINE { string creationDate; string Id; string summary; }; All the members of the struct are std::string. I have an array of these that I need to get back to the C#. What's the best way to do this? I suspect someone is going to say, "hey, you can't just send std::string over COM like that. If so, fine, but what's the best way to modidfy the struct? Change the std::string to BSTR? And then how do I, 1) Set up the IDL to pass an array of structs (structs with BSTR or std::string) 2) If I must use SAFEARRAYS, how do I fill the SAFEARRAYS with the structs. I'm not familiar with COM except for use with simple types. Thanks, Dave

    Read the article

  • How can I reject a Windows "Service Stop" request in ATL 7?

    - by Matt Dillard
    I have a Windows service built upon ATL 7's CAtlServiceModuleT class. This service serves up COM objects that are used by various applications on the system, and these other applications naturally start getting errors if the service is stopped while they are still running. I know that ATL DLLs solve this problem by returning S_OK in DllCanUnloadNow() if CComModule's GetLockCount() returns 0. That is, it checks to make sure no one is currently using any COM objects served up by the DLL. I want equivalent functionality in the service. Here is what I've done in my override of CAtlServiceModuleT::OnStop(): void CMyServiceModule::OnStop() { if( GetLockCount() != 0 ) { return; } BaseClass::OnStop(); } Now, when the user attempts to Stop the service from the Services panel, they are presented with an error message: Windows could not stop the XYZ service on Local Computer. The service did not return an error. This could be an internal Windows error or an internal service error. If the problem persists, contact your system administrator. The Stop request is indeed refused, but it appears to put the service in a bad state. A second Stop request results in this error message: Windows could not stop the XYZ service on Local Computer. Error 1061: The service cannot accept control messages at this time. Interestingly, the service does actually stop this time (although I'd rather it not, since there are still outstanding COM references). I have two questions: Is it considered bad practice for a service to refuse to stop when asked? Is there a polite way to signify that the Stop request is being refused; one that doesn't put the Service into a bad state?

    Read the article

  • Exposing a .Net Service

    - by Dave
    I have written a Windows Service in .Net and I want to expose the classes to be called by other .Net code. Specifically, I have an API that I want to expose via a DLL that will be placed in the GAC, and I want the DLL in the GAC to use the classes of the .Net Windows Service. I need this architecture as the code in the Windows Service needs to be run as a different user/account as the caller of the API (the account would be created at install time). My plan was to expose the Windows Service classes via COM (regasm.exe to register and tlbexp.exe to create the type library), and then call the classes in the GAC DLL via COM (imported via tlbimp.exe). However I get the following error from tlbimp: TlbImp : error TI0000 : System.Runtime.InteropServices.COMException - Type library '' was exported from a CLR assembly and cannot be re- imported as a CLR assembly. This implies to me that my method is not going to easily work. I can only think that I might need a C++ DLL as a bridge for my GAC DLL to invoke the COM calls, but this seems like a nasty solution. I am basically looking for suggestions. Does anyone know how to expose classes of a Windows Service written in .Net to other .Net code?

    Read the article

  • Response.Redirect in a COM+ Object Called from Classic ASP Page

    - by ajdams
    Basically we moved from IIS 5 to IIS 7 and I am trying to update some of our old COM objects to .NET by rewriting them in C#. What I am have so far is a Classic ASP page calling the COM+ object and then I am trying to do a simple redirect within the COM+ object (this is just for testing purposes, it's not what the object will do eventually). My problem/question is, why does the redirect call not work properly? Am I doing something wrong or can you not redirect within a COM+ object? All that happens is a blank white page comes up and if I check the IIS logs, I see no errors. Here is my code so far: In Classic ASP (the call to COM+) Set oBankReg = CreateObject("BVSRegistration.SignIn") oBankReg.GetBankId(bankid) Code in C# COM object: using System; using System.Web; using System.Text; using System.EnterpriseServices; using System.Collections.Generic; using System.Runtime.InteropServices; [assembly: ApplicationName("BVSRegistration")] [assembly: Description("COM+ upgrade of the BVSRegistration VB6 SignIn.cls.")] [assembly: ApplicationActivation(ActivationOption.Server)] [assembly: ApplicationAccessControl(false, AccessChecksLevel = AccessChecksLevelOption.ApplicationComponent)] namespace BVSRegistration { public class SignIn : ServicedComponent { public void GetBankId(string bankid) { HttpContext.Current.Response.Redirect("http://www.google.com"); } } } Any ideas? Thanks

    Read the article