Search Results

Search found 7992 results on 320 pages for 'hp power protector'.

Page 74/320 | < Previous Page | 70 71 72 73 74 75 76 77 78 79 80 81  | Next Page >

  • HTML5 - Does it have the power to handle a large 2D game with a huge world?

    - by user15858
    I have been using XNA game studio, but due to private reasons (as well as the ability to publish anywhere & my heavy interest in isogenic engine), I would like to switch to HTML5. However, I have very high 2D graphic demands for my game. The game itself will have a HDD size of anywhere between 6GB (min) to 12GB (max) which would be a full game deployed offline. The size of the images aren't significantly large, so streaming would be entirely possible if only those assets required were streamed as needed. The game has a massive file size because of the sheer amount of content. For some images or spritesheets, they would be quite massive. (ex. a very large Dragon, which if animated in a spritesheet would be split into two 4096x4096 sheets or one 8192x8192 sheet). Most assets would be very small, and about 7MB for a full character with 15 animations in every direction (all animations not required immediately) so in the size of a few hundred KB to download before the game loads. My question, however, is if the graphical power of HTML5 is enough to animate several characters on screen at once, when it flips through frames quite rapidly. All my sprites have about 25 frames per animation, 5 directions (a spritesheet for each direction & animation), and run at 30fps. Upon changing direction, animation, or a new character entering, spritesheets would change and be constantly loading/unloading. If I pack all directions in a single sheet, it would be about 2048x2048 per sheet. Most frameworks have no problem with this, but I am afraid from what I read that HTML5's graphical capabilities will limit me. Since it takes significant time simply to animate characters in any language, I'd like a quick answer.

    Read the article

  • Maxtor 500GB external hard drive not being detected but power is going to it?

    - by ClarkeyBoy
    I have 2 * Maxtor Onetouch 4 Lite 500GB external hard drives (part no. 9NT2A4-500). They both used to work fine on my old laptop (an Acer) but I have not used them for about a year, since my laptop was stolen and I got this one (also an Acer [Aspire 7738G]). I have one plugged into the mains with one of the leads I believe was supplied with them. It appears to be receiving power as it is warm and the power light (on the unit itself) is on; also the mains adapter is fairly warm. I also have it plugged into my laptop with a USB lead which I have tested on my mp3 player (so I know it works). However my hard drive is not showing on my computer. I have tried checking for new hardware, installing the software that was supplied with it, checking drive letters in case it is registered as C: or something stupid, checking for problems etc... I can't find any cause for it to do this. It does appear to be starting up and, possibly, shutting down and restarting constantly (that's what it sounds like altho I can't be certain). I have had both hard drives stored in different places for the last year and they're both doing the same thing.. if it was only one then I'd guess it had got damaged or corrupted or something but since it is both I doubt this is it. The only things in common with both of them are the leads and the laptop, however I know the USB lead works and guess the mains lead works as there is power going to the unit. Has anyone come across this before or does anyone have any idea what the cause / solution to the problem is? Any help would be greatly appreciated. Regards, Richard

    Read the article

  • System halts for a fraction of second after every 2-3 seconds

    - by iSam
    I'm using Windows 7 on my HP ProBook 4250s. The problem I face is that my system halts for a fraction of second after every 2-3 seconds. These jerks are not letting me concentrate or work properly. This happens even when I'm just typing in notepad while no other application is running. I tried to install every driver from HP's website and there's no item in device manager marked with yellow icon. Following are my system specs: Machine: HP ProBook 4250s OS: Windows 7 professional RAM: 2GB Processor: Intel Core i3 2.27GHz Following is my HijackThis Log: **Logfile of HijackThis v1.99.1** Scan saved at 9:34:03 PM, on 11/13/2012 Platform: Unknown Windows (WinNT 6.01.3504) MSIE: Internet Explorer v9.00 (9.00.8112.16450) **Running processes:** C:\Windows\system32\taskhost.exe C:\Windows\System32\rundll32.exe C:\Windows\system32\Dwm.exe C:\Windows\Explorer.EXE C:\Windows\System32\igfxtray.exe C:\Windows\System32\hkcmd.exe C:\Windows\System32\igfxpers.exe C:\Program Files\Synaptics\SynTP\SynTPEnh.exe C:\Program Files\PowerISO\PWRISOVM.EXE C:\Program Files\AVAST Software\Avast\AvastUI.exe C:\Program Files\Free Download Manager\fdm.exe C:\Windows\system32\wuauclt.exe C:\Program Files\Windows Media Player\wmplayer.exe C:\Program Files\Microsoft Office\Office12\WINWORD.EXE C:\HijackThis\HijackThis.exe R1 - HKCU\Software\Microsoft\Internet Explorer\Main,Search Page = http://go.microsoft.com/fwlink/?LinkId=54896 R0 - HKCU\Software\Microsoft\Internet Explorer\Main,Start Page = http://bing.com/ R1 - HKLM\Software\Microsoft\Internet Explorer\Main,Default_Page_URL = http://go.microsoft.com/fwlink/?LinkId=69157 R1 - HKLM\Software\Microsoft\Internet Explorer\Main,Default_Search_URL = http://go.microsoft.com/fwlink/?LinkId=54896 R1 - HKLM\Software\Microsoft\Internet Explorer\Main,Search Page = http://go.microsoft.com/fwlink/?LinkId=54896 R0 - HKLM\Software\Microsoft\Internet Explorer\Main,Start Page = http://go.microsoft.com/fwlink/?LinkId=69157 R0 - HKLM\Software\Microsoft\Internet Explorer\Search,SearchAssistant = R0 - HKLM\Software\Microsoft\Internet Explorer\Search,CustomizeSearch = R0 - HKCU\Software\Microsoft\Internet Explorer\Toolbar,LinksFolderName = R3 - URLSearchHook: (no name) - {7473b6bd-4691-4744-a82b-7854eb3d70b6} - (no file) O2 - BHO: Adobe PDF Reader Link Helper - {06849E9F-C8D7-4D59-B87D-784B7D6BE0B3} - C:\Program Files\Common Files\Adobe\Acrobat\ActiveX\AcroIEHelper.dll O2 - BHO: Babylon toolbar helper - {2EECD738-5844-4a99-B4B6-146BF802613B} - (no file) O2 - BHO: MrFroggy - {856E12B5-22D7-4E22-9ACA-EA9A008DD65B} - C:\Program Files\Minibar\Froggy.dll O2 - BHO: avast! WebRep - {8E5E2654-AD2D-48bf-AC2D-D17F00898D06} - C:\Program Files\AVAST Software\Avast\aswWebRepIE.dll O2 - BHO: Windows Live ID Sign-in Helper - {9030D464-4C02-4ABF-8ECC-5164760863C6} - C:\Program Files\Common Files\Microsoft Shared\Windows Live\WindowsLiveLogin.dll O2 - BHO: Minibar BHO - {AA74D58F-ACD0-450D-A85E-6C04B171C044} - C:\Program Files\Minibar\Kango.dll O2 - BHO: Free Download Manager - {CC59E0F9-7E43-44FA-9FAA-8377850BF205} - C:\Program Files\Free Download Manager\iefdm2.dll O2 - BHO: HP Network Check Helper - {E76FD755-C1BA-4DCB-9F13-99BD91223ADE} - C:\Program Files\Hewlett-Packard\HP Support Framework\Resources\HPNetworkCheck\HPNetworkCheckPlugin.dll O3 - Toolbar: (no name) - {98889811-442D-49dd-99D7-DC866BE87DBC} - (no file) O3 - Toolbar: avast! WebRep - {8E5E2654-AD2D-48bf-AC2D-D17F00898D06} - C:\Program Files\AVAST Software\Avast\aswWebRepIE.dll O4 - HKLM\..\Run: [IgfxTray] C:\Windows\system32\igfxtray.exe O4 - HKLM\..\Run: [HotKeysCmds] C:\Windows\system32\hkcmd.exe O4 - HKLM\..\Run: [Persistence] C:\Windows\system32\igfxpers.exe O4 - HKLM\..\Run: [SynTPEnh] %ProgramFiles%\Synaptics\SynTP\SynTPEnh.exe O4 - HKLM\..\Run: [PWRISOVM.EXE] C:\Program Files\PowerISO\PWRISOVM.EXE -startup O4 - HKLM\..\Run: [AdobeAAMUpdater-1.0] "C:\Program Files\Common Files\Adobe\OOBE\PDApp\UWA\UpdaterStartupUtility.exe" O4 - HKLM\..\Run: [AdobeCS6ServiceManager] "C:\Program Files\Common Files\Adobe\CS6ServiceManager\CS6ServiceManager.exe" -launchedbylogin O4 - HKLM\..\Run: [SwitchBoard] C:\Program Files\Common Files\Adobe\SwitchBoard\SwitchBoard.exe O4 - HKLM\..\Run: [ROC_roc_ssl_v12] "C:\Program Files\AVG Secure Search\ROC_roc_ssl_v12.exe" / /PROMPT /CMPID=roc_ssl_v12 O4 - HKLM\..\Run: [avast] "C:\Program Files\AVAST Software\Avast\avastUI.exe" /nogui O4 - HKLM\..\Run: [Wordinn English to Urdu Dictionary] "C:\Program Files\Wordinn\Urdu Dictionary\bin\Lugat.exe" -h O4 - HKLM\..\Run: [Adobe Reader Speed Launcher] "C:\Program Files\Adobe\Reader 8.0\Reader\Reader_sl.exe" O4 - HKCU\..\Run: [Comparator Fast] "C:\Program Files\Interdesigner Software\Comparator Fast\ComparatorFast.exe" /STARTUP O4 - HKCU\..\Run: [Free Download Manager] "C:\Program Files\Free Download Manager\fdm.exe" -autorun O8 - Extra context menu item: Download all with Free Download Manager - file://C:\Program Files\Free Download Manager\dlall.htm O8 - Extra context menu item: Download selected with Free Download Manager - file://C:\Program Files\Free Download Manager\dlselected.htm O8 - Extra context menu item: Download video with Free Download Manager - file://C:\Program Files\Free Download Manager\dlfvideo.htm O8 - Extra context menu item: Download with Free Download Manager - file://C:\Program Files\Free Download Manager\dllink.htm O8 - Extra context menu item: E&xport to Microsoft Excel - res://C:\PROGRA~1\MICROS~2\Office12\EXCEL.EXE/3000 O9 - Extra button: @C:\Program Files\Hewlett-Packard\HP Support Framework\Resources\HPNetworkCheck\HPNetworkCheckPlugin.dll,-103 - {25510184-5A38-4A99-B273-DCA8EEF6CD08} - C:\Program Files\Hewlett-Packard\HP Support Framework\Resources\HPNetworkCheck\NCLauncherFromIE.exe O9 - Extra 'Tools' menuitem: @C:\Program Files\Hewlett-Packard\HP Support Framework\Resources\HPNetworkCheck\HPNetworkCheckPlugin.dll,-102 - {25510184-5A38-4A99-B273-DCA8EEF6CD08} - C:\Program Files\Hewlett-Packard\HP Support Framework\Resources\HPNetworkCheck\NCLauncherFromIE.exe O9 - Extra button: Research - {92780B25-18CC-41C8-B9BE-3C9C571A8263} - C:\PROGRA~1\MICROS~2\Office12\REFIEBAR.DLL O9 - Extra button: Change your facebook look - {AAA38851-3CFF-475F-B5E0-720D3645E4A5} - C:\Program Files\Minibar\MinibarButton.dll O10 - Unknown file in Winsock LSP: c:\windows\system32\nlaapi.dll O10 - Unknown file in Winsock LSP: c:\windows\system32\napinsp.dll O10 - Unknown file in Winsock LSP: c:\program files\common files\microsoft shared\windows live\wlidnsp.dll O10 - Unknown file in Winsock LSP: c:\program files\common files\microsoft shared\windows live\wlidnsp.dll O11 - Options group: [ACCELERATED_GRAPHICS] Accelerated graphics O11 - Options group: [INTERNATIONAL] International O13 - Gopher Prefix: O17 - HKLM\System\CCS\Services\Tcpip\..\{920289D7-5F75-4181-9A37-5627EAA163E3}: NameServer = 8.8.8.8,8.8.4.4 O17 - HKLM\System\CCS\Services\Tcpip\..\{AE83ED2F-EF14-4066-ACE2-C4ED07A68EAA}: NameServer = 9.9.9.9,8.8.8.8 O18 - Protocol: ms-help - {314111C7-A502-11D2-BBCA-00C04F8EC294} - C:\Program Files\Common Files\Microsoft Shared\Help\hxds.dll O18 - Protocol: skype4com - {FFC8B962-9B40-4DFF-9458-1830C7DD7F5D} - C:\PROGRA~1\COMMON~1\Skype\SKYPE4~1.DLL O18 - Protocol: wlpg - {E43EF6CD-A37A-4A9B-9E6F-83F89B8E6324} - C:\Program Files\Windows Live\Photo Gallery\AlbumDownloadProtocolHandler.dll O18 - Filter hijack: text/xml - {807563E5-5146-11D5-A672-00B0D022E945} - C:\PROGRA~1\COMMON~1\MICROS~1\OFFICE12\MSOXMLMF.DLL O20 - AppInit_DLLs: c:\progra~2\browse~1\23787~1.43\{16cdf~1\browse~1.dll c:\progra~2\browse~1\22630~1.40\{16cdf~1\browse~1.dll O20 - Winlogon Notify: igfxcui - C:\Windows\SYSTEM32\igfxdev.dll O23 - Service: avast! Antivirus - AVAST Software - C:\Program Files\AVAST Software\Avast\AvastSvc.exe O23 - Service: Google Software Updater (gusvc) - Google - C:\Program Files\Google\Common\Google Updater\GoogleUpdaterService.exe O23 - Service: HP Support Assistant Service - Hewlett-Packard Company - C:\Program Files\Hewlett-Packard\HP Support Framework\hpsa_service.exe O23 - Service: HP Quick Synchronization Service (HPDrvMntSvc.exe) - Hewlett-Packard Company - C:\Program Files\Hewlett-Packard\Shared\HPDrvMntSvc.exe O23 - Service: HP Software Framework Service (hpqwmiex) - Hewlett-Packard Company - C:\Program Files\Hewlett-Packard\Shared\hpqWmiEx.exe O23 - Service: HP Service (hpsrv) - Hewlett-Packard Company - C:\Windows\system32\Hpservice.exe O23 - Service: Intel(R) Management and Security Application Local Management Service (LMS) - Intel Corporation - C:\Program Files\Intel\Intel(R) Management Engine Components\LMS\LMS.exe O23 - Service: Mozilla Maintenance Service (MozillaMaintenance) - Mozilla Foundation - C:\Program Files\Mozilla Maintenance Service\maintenanceservice.exe O23 - Service: @%SystemRoot%\system32\qwave.dll,-1 (QWAVE) - Unknown owner - %windir%\system32\svchost.exe (file missing) O23 - Service: @%SystemRoot%\system32\seclogon.dll,-7001 (seclogon) - Unknown owner - %windir%\system32\svchost.exe (file missing) O23 - Service: Skype Updater (SkypeUpdate) - Skype Technologies - C:\Program Files\Skype\Updater\Updater.exe O23 - Service: Adobe SwitchBoard (SwitchBoard) - Adobe Systems Incorporated - C:\Program Files\Common Files\Adobe\SwitchBoard\SwitchBoard.exe O23 - Service: Intel(R) Management & Security Application User Notification Service (UNS) - Intel Corporation - C:\Program Files\Intel\Intel(R) Management Engine Components\UNS\UNS.exe O23 - Service: @%PROGRAMFILES%\Windows Media Player\wmpnetwk.exe,-101 (WMPNetworkSvc) - Unknown owner - %PROGRAMFILES%\Windows Media Player\wmpnetwk.exe (file missing)

    Read the article

  • Need to hookup HP dv7-3085dx with Nvidia GeForce GT 230M to my Dell 30 inch LCD 3007WFP at max resol

    - by user14660
    I recently bought an HP laptop (dv7-3085dx) (http://reviews.cnet.com/laptops/hp-pavilion-dv7-3085dx/4505-3121_7-33776108.html) which is supposed to have a pretty good video card (NVIDIA GeForce GT 230M). The card is supposed to output a max resolution of 2560x1600 which is also the max resolution of my monitor (http://www.ubergizmo.com/15/archives/2006/02/dell_3007wfp_on_dell_2001fp_action_8_megapixel_desktop.html). Now I bought an HDMI to dual link dvi (http://www.amazon.com/gp/product/B002KKLYDK/ref=oss_product) cable...this is after Best Buy's 70 dollar hdmi to dvi (perhaps it was 'single' link?) didn't give me the best resolution. In windows 7, when I try to set the max resolution for my 30 in monitor, I only get 1280x800...which is absurd. The monitor is great, I love the laptop and the video card supposedly supports such resolutions. So I can't figure out why I'm not getting better resolution (by the way, when i "detect" my monitor in windows 7, it is shown correctly as DELL 3007WFP!).

    Read the article

  • Ubuntu 10.04 recognizing USB 2.0 external HD as USB 1.1

    - by btucker
    When I connect the USB 2.0 drive I see this: usb 1-4.3: new full speed USB device using ohci_hcd and address 5 so I know it's getting seen as USB 1.1. usb-devices shows that it really is USB 2.0 and connected to a USB 2.0 hub: T: Bus=01 Lev=01 Prnt=01 Port=03 Cnt=01 Dev#= 2 Spd=12 MxCh= 4 D: Ver= 2.00 Cls=09(hub ) Sub=00 Prot=00 MxPS=64 #Cfgs= 1 P: Vendor=05e3 ProdID=0608 Rev=77.61 S: Product=USB2.0 Hub C: #Ifs= 1 Cfg#= 1 Atr=e0 MxPwr=100mA I: If#= 0 Alt= 0 #EPs= 1 Cls=09(hub ) Sub=00 Prot=00 Driver=hub T: Bus=01 Lev=02 Prnt=02 Port=01 Cnt=01 Dev#= 4 Spd=12 MxCh= 0 D: Ver= 2.00 Cls=00(>ifc ) Sub=00 Prot=00 MxPS=64 #Cfgs= 1 P: Vendor=13fd ProdID=1340 Rev=02.10 S: Manufacturer=Generic S: Product=External C: #Ifs= 1 Cfg#= 1 Atr=c0 MxPwr=2mA I: If#= 0 Alt= 0 #EPs= 2 Cls=08(stor.) Sub=06 Prot=50 Driver=usb-storage It seems the problem is that root hub is: T: Bus=01 Lev=00 Prnt=00 Port=00 Cnt=00 Dev#= 1 Spd=12 MxCh=10 D: Ver= 1.10 Cls=09(hub ) Sub=00 Prot=00 MxPS=64 #Cfgs= 1 P: Vendor=1d6b ProdID=0001 Rev=02.06 S: Manufacturer=Linux 2.6.32-25-server ohci_hcd S: Product=OHCI Host Controller S: SerialNumber=0000:00:02.0 C: #Ifs= 1 Cfg#= 1 Atr=e0 MxPwr=0mA I: If#= 0 Alt= 0 #EPs= 1 Cls=09(hub ) Sub=00 Prot=00 Driver=hub And there's no mention of ehci_hcd. lsusb -t gives me: /: Bus 01.Port 1: Dev 1, Class=root_hub, Driver=ohci_hcd/10p, 12M |__ Port 4: Dev 2, If 0, Class=hub, Driver=hub/4p, 12M |__ Port 2: Dev 4, If 0, Class=stor., Driver=usb-storage, 12M |__ Port 3: Dev 5, If 0, Class=stor., Driver=usb-storage, 12M |__ Port 6: Dev 3, If 0, Class=stor., Driver=usb-storage, 12M It seems like I'm missing something which would allow the OS to see USB 2.0 devices. Can anyone point me in the right direction? EDIT Full lsusb -v output: Bus 001 Device 005: ID 13fd:1340 Initio Corporation Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 idVendor 0x13fd Initio Corporation idProduct 0x1340 bcdDevice 2.10 iManufacturer 1 Generic iProduct 2 External iSerial 3 57442D574341595930323337 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 32 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xc0 Self Powered MaxPower 2mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 8 Mass Storage bInterfaceSubClass 6 SCSI bInterfaceProtocol 80 Bulk (Zip) iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0040 1x 64 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x02 EP 2 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0040 1x 64 bytes bInterval 0 Device Qualifier (for other device speed): bLength 10 bDescriptorType 6 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 bNumConfigurations 1 Device Status: 0x0001 Self Powered Bus 001 Device 002: ID 05e3:0608 Genesys Logic, Inc. USB-2.0 4-Port HUB Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 0 Full speed (or root) hub bMaxPacketSize0 64 idVendor 0x05e3 Genesys Logic, Inc. idProduct 0x0608 USB-2.0 4-Port HUB bcdDevice 77.61 iManufacturer 0 iProduct 1 USB2.0 Hub iSerial 0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 25 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 100mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 Hub bInterfaceSubClass 0 Unused bInterfaceProtocol 0 Full speed (or root) hub iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0001 1x 1 bytes bInterval 255 Hub Descriptor: bLength 9 bDescriptorType 41 nNbrPorts 4 wHubCharacteristic 0x00e0 Ganged power switching Ganged overcurrent protection Port indicators bPwrOn2PwrGood 50 * 2 milli seconds bHubContrCurrent 100 milli Ampere DeviceRemovable 0x00 PortPwrCtrlMask 0xff Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0103 power enable connect Port 3: 0000.0103 power enable connect Port 4: 0000.0100 power Device Qualifier (for other device speed): bLength 10 bDescriptorType 6 bcdUSB 2.00 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 1 Single TT bMaxPacketSize0 64 bNumConfigurations 1 Device Status: 0x0001 Self Powered Bus 001 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 1.10 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 0 Full speed (or root) hub bMaxPacketSize0 64 idVendor 0x1d6b Linux Foundation idProduct 0x0001 1.1 root hub bcdDevice 2.06 iManufacturer 3 Linux 2.6.32-25-server ohci_hcd iProduct 2 OHCI Host Controller iSerial 1 0000:00:02.0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 25 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 Hub bInterfaceSubClass 0 Unused bInterfaceProtocol 0 Full speed (or root) hub iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0002 1x 2 bytes bInterval 255 Hub Descriptor: bLength 11 bDescriptorType 41 nNbrPorts 10 wHubCharacteristic 0x0002 No power switching (usb 1.0) Ganged overcurrent protection bPwrOn2PwrGood 1 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 0x00 PortPwrCtrlMask 0xff 0xff Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0100 power Port 3: 0000.0100 power Port 4: 0000.0103 power enable connect Port 5: 0000.0100 power Port 6: 0000.0103 power enable connect Port 7: 0000.0100 power Port 8: 0000.0100 power Port 9: 0000.0100 power Port 10: 0000.0100 power Device Status: 0x0003 Self Powered Remote Wakeup Enabled

    Read the article

  • How to track usage of a HP Network Printer?

    - by NinethSense
    I have a HP Printer (HP Color LaserJet CM1312 MFP Series PCL 6) installed which is used by nearly 200 PCs through LAN. I want to track the usage like: Who (IP Address) initiated the print task Time Status: Success or Failure How many Pages Color or Gray Scale etc. I checked the manuals and nothing about this requirement is available. The built-in control panel log displays only last 10 activities. Is there a way to track these information? Is there an API avaialble so that I can make an application myself?

    Read the article

  • Can I run Linux on the HP Mini from Verizon Wireless, with a built-in 3G modem, and connect using the built in modem?

    - by Parker
    I apologize if my question made little sense, I am very tired at the moment. Anyway, Recently I purchases the HP Mini from Verizon Wireless. It runs on the Intel Atom processor and came with Windows 7 Starter Edition, which is quite possibly the worst and most restrictive OS I have ever used. I plan on installing CRUX, after doing a little research on minimal, free, Linux operating systems, as I am working on web programming using Python, among other things. My only worry is that, because my HP Mini uses a built in wireless card (and I have no wifi connection, only a 3G connection) that has a "mobile access" connection to Verizon wireless, I am not sure if after installing CRUX that I would still be able to connect using this option. I have never used Linux before, and am hoping this will work. So if anybody has experience with this...please answer, can I connect to vzw 3G with linux, using an internal mobile access card...

    Read the article

  • Are there HP Infinihost III ex drivers for windows available?

    - by Matt
    I picked up some infiniband cards off ebay for development/testing purposes. I was hoping that there would be some drivers available under windows 7, but it doesn't seem to be recognised by the OFED software which would seem to contain windows drivers. They are however immediately picked up by Ubuntu and drivers are loaded. Are these cards supported under windows 7 at all? mstflint under linux reports: Image type: Failsafe FW Version: 4.8.930 I.S. Version: 1 Device ID: 25208 Chip Revision: A0 Description: Node Port1 Port2 Sys image GUIDs: 001a4bffff0c9374 001a4bffff0c9375 001a4bffff0c9376 001a4bffff0c9377 Board ID: (HP_0060000001) VSD: PSID: HP_0060000001 From what I can tell they are the following: HP IB 4X DDR PCI-e DUAL PORT HCA (HP part number 409376-B21)

    Read the article

  • Connecting Dell XPS 17/HP Pavilion dv7 (nvidia GT 650M) to Apple LED Cinema Display for 2560x1440 resolution from notebook

    - by alphaTrader
    Is there any way to run higher than 1080p resolution from a Dell XPS 15/17 or HP Pavilion laptop? Specifically, I am planning to buy Dell XPS L721X or HP Pavilion dv7-7005tx with nvidia GeForce GT 650M and connect it to the Apple LED Cinema display via mini Displayport (I don't think Thunderbolt is supported on these notebooks). The idea is to get 1080p on the notebook and 2560x1440 on the main display. Only one of the montitors is active at any time. I asked Dell and they weren't of much help.

    Read the article

  • app engine's back referencing is too slow. How can I make it faster?

    - by Ray Yun
    Google app engine has smart feature named back references and I usually iterate them where the traditional SQL's computed column need to be used. Just imagine that need to accumulate specific force's total hp. class Force(db.Model): hp = db.IntegerProperty() class UnitGroup(db.Model): force = db.ReferenceProperty(reference_class=Force,collection_name="groups") hp = db.IntegerProperty() class Unit(db.Model): group = db.ReferenceProperty(reference_class=UnitGroup,collection_name="units") hp = db.IntegerProperty() When I code like following, it was horribly slow (almost 3s) with 20 forces with single group - single unit. (I guess back-referencing force reload sub entities. Am I right?) def get_hp(self): hp = 0 for group in self.groups: group_hp = 0 for unit in group.units: group_hp += unit.hp hp += group_hp return hp How can I optimize this code? Please consider that there are more properties should be computed for each force/unit-groups and I don't want to save these collective properties to each entities. :)

    Read the article

  • Ubuntu hangs after replugging the modem

    - by Iftekhar Ahmed Shafi
    I am facing this issue on Ubuntu 12.04, which is for my Wimax modem with beceem chipset. If I replug the device Ubuntu goes in hang state. Its happens very often. If I plug the USB and restart it works most of the time. But it is very annoying to restart every time it hangs. The modem works smoothly in Windows 7. And it used to work OK in Ubuntu 11.10. Jun 13 19:25:54 iftekhar-HP-520-Notebook-PC dbus[1102]: [system] Activating service name='org.freedesktop.UDisks' (using servicehelper) Jun 13 19:25:54 iftekhar-HP-520-Notebook-PC dbus[1102]: [system] Successfully activated service 'org.freedesktop.UDisks' Jun 13 19:26:00 iftekhar-HP-520-Notebook-PC goa[2168]: goa-daemon version 3.4.0 starting [main.c:112, main()] Jun 13 19:26:47 iftekhar-HP-520-Notebook-PC udevd[432]: timeout 'cdrom_id --lock-media /dev/sr1' Jun 13 19:26:48 iftekhar-HP-520-Notebook-PC udevd[432]: timeout: killing 'cdrom_id --lock-media /dev/sr1' [1072] Jun 13 19:26:49 iftekhar-HP-520-Notebook-PC kernel: [ 85.820162] sr 2:0:0:0: Device offlined - not ready after error recovery Jun 13 19:26:49 iftekhar-HP-520-Notebook-PC udevd[432]: timeout: killing 'cdrom_id --lock-media /dev/sr1' [1072] Jun 13 19:27:20 udevd[432]: last message repeated 31 times Jun 13 19:27:25 udevd[432]: last message repeated 4 times What can I do to avoid this hangs and restarts?

    Read the article

  • Entity communication: Message queue vs Publish/Subscribe vs Signal/Slots

    - by deft_code
    How do game engine entities communicate? Two use cases: How would entity_A send a take-damage message to entity_B? How would entity_A query entity_B's HP? Here's what I've encountered so far: Message queue entity_A creates a take-damage message and posts it to entity_B's message queue. entity_A creates a query-hp message and posts it to entity_B. entity_B in return creates an response-hp message and posts it to entity_A. Publish/Subscribe entity_B subscribes to take-damage messages (possibly with some preemptive filtering so only relevant message are delivered). entity_A produces take-damage message that references entity_B. entity_A subscribes to update-hp messages (possibly filtered). Every frame entity_B broadcasts update-hp messages. Signal/Slots ??? entity_A connects an update-hp slot to entity_B's update-hp signal. Something better? Do I have a correct understanding of how these communication schemes would tie into a game engine's entity system? How do entities in commercial game engines communicate?

    Read the article

  • SPARC T4-4 Beats 8-CPU IBM POWER7 on TPC-H @3000GB Benchmark

    - by Brian
    Oracle's SPARC T4-4 server delivered a world record TPC-H @3000GB benchmark result for systems with four processors. This result beats eight processor results from IBM (POWER7) and HP (x86). The SPARC T4-4 server also delivered better performance per core than these eight processor systems from IBM and HP. Comparisons below are based upon system to system comparisons, highlighting Oracle's complete software and hardware solution. This database world record result used Oracle's Sun Storage 2540-M2 arrays (rotating disk) connected to a SPARC T4-4 server running Oracle Solaris 11 and Oracle Database 11g Release 2 demonstrating the power of Oracle's integrated hardware and software solution. The SPARC T4-4 server based configuration achieved a TPC-H scale factor 3000 world record for four processor systems of 205,792 QphH@3000GB with price/performance of $4.10/QphH@3000GB. The SPARC T4-4 server with four SPARC T4 processors (total of 32 cores) is 7% faster than the IBM Power 780 server with eight POWER7 processors (total of 32 cores) on the TPC-H @3000GB benchmark. The SPARC T4-4 server is 36% better in price performance compared to the IBM Power 780 server on the TPC-H @3000GB Benchmark. The SPARC T4-4 server is 29% faster than the IBM Power 780 for data loading. The SPARC T4-4 server is up to 3.4 times faster than the IBM Power 780 server for the Refresh Function. The SPARC T4-4 server with four SPARC T4 processors is 27% faster than the HP ProLiant DL980 G7 server with eight x86 processors on the TPC-H @3000GB benchmark. The SPARC T4-4 server is 52% faster than the HP ProLiant DL980 G7 server for data loading. The SPARC T4-4 server is up to 3.2 times faster than the HP ProLiant DL980 G7 for the Refresh Function. The SPARC T4-4 server achieved a peak IO rate from the Oracle database of 17 GB/sec. This rate was independent of the storage used, as demonstrated by the TPC-H @3000TB benchmark which used twelve Sun Storage 2540-M2 arrays (rotating disk) and the TPC-H @1000TB benchmark which used four Sun Storage F5100 Flash Array devices (flash storage). [*] The SPARC T4-4 server showed linear scaling from TPC-H @1000GB to TPC-H @3000GB. This demonstrates that the SPARC T4-4 server can handle the increasingly larger databases required of DSS systems. [*] The SPARC T4-4 server benchmark results demonstrate a complete solution of building Decision Support Systems including data loading, business questions and refreshing data. Each phase usually has a time constraint and the SPARC T4-4 server shows superior performance during each phase. [*] The TPC believes that comparisons of results published with different scale factors are misleading and discourages such comparisons. Performance Landscape The table lists the leading TPC-H @3000GB results for non-clustered systems. TPC-H @3000GB, Non-Clustered Systems System Processor P/C/T – Memory Composite(QphH) $/perf($/QphH) Power(QppH) Throughput(QthH) Database Available SPARC Enterprise M9000 3.0 GHz SPARC64 VII+ 64/256/256 – 1024 GB 386,478.3 $18.19 316,835.8 471,428.6 Oracle 11g R2 09/22/11 SPARC T4-4 3.0 GHz SPARC T4 4/32/256 – 1024 GB 205,792.0 $4.10 190,325.1 222,515.9 Oracle 11g R2 05/31/12 SPARC Enterprise M9000 2.88 GHz SPARC64 VII 32/128/256 – 512 GB 198,907.5 $15.27 182,350.7 216,967.7 Oracle 11g R2 12/09/10 IBM Power 780 4.1 GHz POWER7 8/32/128 – 1024 GB 192,001.1 $6.37 210,368.4 175,237.4 Sybase 15.4 11/30/11 HP ProLiant DL980 G7 2.27 GHz Intel Xeon X7560 8/64/128 – 512 GB 162,601.7 $2.68 185,297.7 142,685.6 SQL Server 2008 10/13/10 P/C/T = Processors, Cores, Threads QphH = the Composite Metric (bigger is better) $/QphH = the Price/Performance metric in USD (smaller is better) QppH = the Power Numerical Quantity QthH = the Throughput Numerical Quantity The following table lists data load times and refresh function times during the power run. TPC-H @3000GB, Non-Clustered Systems Database Load & Database Refresh System Processor Data Loading(h:m:s) T4Advan RF1(sec) T4Advan RF2(sec) T4Advan SPARC T4-4 3.0 GHz SPARC T4 04:08:29 1.0x 67.1 1.0x 39.5 1.0x IBM Power 780 4.1 GHz POWER7 05:51:50 1.5x 147.3 2.2x 133.2 3.4x HP ProLiant DL980 G7 2.27 GHz Intel Xeon X7560 08:35:17 2.1x 173.0 2.6x 126.3 3.2x Data Loading = database load time RF1 = power test first refresh transaction RF2 = power test second refresh transaction T4 Advan = the ratio of time to T4 time Complete benchmark results found at the TPC benchmark website http://www.tpc.org. Configuration Summary and Results Hardware Configuration: SPARC T4-4 server 4 x SPARC T4 3.0 GHz processors (total of 32 cores, 128 threads) 1024 GB memory 8 x internal SAS (8 x 300 GB) disk drives External Storage: 12 x Sun Storage 2540-M2 array storage, each with 12 x 15K RPM 300 GB drives, 2 controllers, 2 GB cache Software Configuration: Oracle Solaris 11 11/11 Oracle Database 11g Release 2 Enterprise Edition Audited Results: Database Size: 3000 GB (Scale Factor 3000) TPC-H Composite: 205,792.0 QphH@3000GB Price/performance: $4.10/QphH@3000GB Available: 05/31/2012 Total 3 year Cost: $843,656 TPC-H Power: 190,325.1 TPC-H Throughput: 222,515.9 Database Load Time: 4:08:29 Benchmark Description The TPC-H benchmark is a performance benchmark established by the Transaction Processing Council (TPC) to demonstrate Data Warehousing/Decision Support Systems (DSS). TPC-H measurements are produced for customers to evaluate the performance of various DSS systems. These queries and updates are executed against a standard database under controlled conditions. Performance projections and comparisons between different TPC-H Database sizes (100GB, 300GB, 1000GB, 3000GB, 10000GB, 30000GB and 100000GB) are not allowed by the TPC. TPC-H is a data warehousing-oriented, non-industry-specific benchmark that consists of a large number of complex queries typical of decision support applications. It also includes some insert and delete activity that is intended to simulate loading and purging data from a warehouse. TPC-H measures the combined performance of a particular database manager on a specific computer system. The main performance metric reported by TPC-H is called the TPC-H Composite Query-per-Hour Performance Metric (QphH@SF, where SF is the number of GB of raw data, referred to as the scale factor). QphH@SF is intended to summarize the ability of the system to process queries in both single and multiple user modes. The benchmark requires reporting of price/performance, which is the ratio of the total HW/SW cost plus 3 years maintenance to the QphH. A secondary metric is the storage efficiency, which is the ratio of total configured disk space in GB to the scale factor. Key Points and Best Practices Twelve Sun Storage 2540-M2 arrays were used for the benchmark. Each Sun Storage 2540-M2 array contains 12 15K RPM drives and is connected to a single dual port 8Gb FC HBA using 2 ports. Each Sun Storage 2540-M2 array showed 1.5 GB/sec for sequential read operations and showed linear scaling, achieving 18 GB/sec with twelve Sun Storage 2540-M2 arrays. These were stand alone IO tests. The peak IO rate measured from the Oracle database was 17 GB/sec. Oracle Solaris 11 11/11 required very little system tuning. Some vendors try to make the point that storage ratios are of customer concern. However, storage ratio size has more to do with disk layout and the increasing capacities of disks – so this is not an important metric in which to compare systems. The SPARC T4-4 server and Oracle Solaris efficiently managed the system load of over one thousand Oracle Database parallel processes. Six Sun Storage 2540-M2 arrays were mirrored to another six Sun Storage 2540-M2 arrays on which all of the Oracle database files were placed. IO performance was high and balanced across all the arrays. The TPC-H Refresh Function (RF) simulates periodical refresh portion of Data Warehouse by adding new sales and deleting old sales data. Parallel DML (parallel insert and delete in this case) and database log performance are a key for this function and the SPARC T4-4 server outperformed both the IBM POWER7 server and HP ProLiant DL980 G7 server. (See the RF columns above.) See Also Transaction Processing Performance Council (TPC) Home Page Ideas International Benchmark Page SPARC T4-4 Server oracle.com OTN Oracle Solaris oracle.com OTN Oracle Database 11g Release 2 Enterprise Edition oracle.com OTN Sun Storage 2540-M2 Array oracle.com OTN Disclosure Statement TPC-H, QphH, $/QphH are trademarks of Transaction Processing Performance Council (TPC). For more information, see www.tpc.org. SPARC T4-4 205,792.0 QphH@3000GB, $4.10/QphH@3000GB, available 5/31/12, 4 processors, 32 cores, 256 threads; IBM Power 780 QphH@3000GB, 192,001.1 QphH@3000GB, $6.37/QphH@3000GB, available 11/30/11, 8 processors, 32 cores, 128 threads; HP ProLiant DL980 G7 162,601.7 QphH@3000GB, $2.68/QphH@3000GB available 10/13/10, 8 processors, 64 cores, 128 threads.

    Read the article

  • Why is cpu power management not working in Server 2012 with Hyper-V?

    - by Roland
    We've been using Server2008R2 with Hyper-V for a couple of years now and chose it at the time because of its ability to make use of Intel SpeedStep and AMD PowerNow! Now with Server 2012 and Hyper-V V3, all power management abilities seem to be gone. The CPUs are always at full speed and our servers need twice the energy as before while idling. (Yes, the CPU P-states are enabled in the BIOS) Is this by design? Is there a workaround to enable cpu power management again? Despite the great new features of Hyper-V 3, this would be a show-stopper for us since we are very concerned about energy consumption.

    Read the article

  • Is it really necessary to call /bin/sync twice before an unmanaged power-off?

    - by Jeremy Friesner
    Hi all, My company sells an "embedded device" which is implemented as a headless Linux box with ext4 on an internal SSD. Some of our users have a habit of doing a "save current settings" on this box, and then cutting power to the unit as soon as the unit reports that the save completed (ie two seconds later). This was causing occasional corruption of the saved files, as the data wouldn't always get flushed to the SSD before the power went out. So I tweaked my software to run /bin/sync immediately after writing the file (after closing the file handle but before notifying the user that the save completed). This appears to fix the issue, but my coworker says that one call to /bin/sync isn't sufficient, and that to be really safe I ought to run /bin/sync twice in a row. That sounds like paranoia to me... Perhaps a habit from earlier versions of Linux or unix whose sync utility didn't work reliably. Does his advice have merit, or should one call to /bin/sync suffice?

    Read the article

  • Does Wake-on-LAN from power state S5 require any OS configuration?

    - by TARehman
    I am configuring a HTPC which I would like to be able to power on using Wake-on-LAN, from the S5 state (full shutdown, still plugged in). The system is running Linux Mint 14 Cinnamon. I'm getting some conflicting information in my searching on the Net. I am not concerned with using WoL to change the state from standby or hibernate to on. Because of the current interface to our TV, the system must be either turned on or turned off. So, basically, this system will cycle from S0 to S5, and from S5 back to S0, and so on. Some tutorials suggest that I need to use ethtool to configure things after enabling WoL in my BIOS, but my understanding is that doing an S5 - S0 power on only requires the BIOS to be configured (since when the computer is in state S5, the OS hasn't even been loaded anyway). Can I use WoL with only the BIOS configured to go from state S5 to S0, or will I need to configure the OS as well?

    Read the article

  • Can I run my MacBook in clamshell mode without being connected to power?

    - by kch
    Hi, At home, I run my MacBook in clamshell mode (closed lid, external display). This works fine when you're connected to the power adapter, but it doesn't work when running on battery. That's how it's supposed to be and Apple has some kb entry on the issue. But it's also lame. You can prevent the machine from sleeping when closed by running InsomniaX, but then it'll assume the builtin display is still active, so you end up with a two-display setup when you really only want the external. This is obviously less than ideal. So, is there any work around, hack, utility, black magic that I can use to make it run in clamshell mode while strictly on battery power? Also, bonus points for a solution that makes the AC status not affect the machine state at all. (Like, you know, it does normally, when not in clamshell.)

    Read the article

  • How do I make a partition usable in windows 7 after power loss?

    - by user1306322
    A few days ago I was installing some software and power went down. When I rebooted, the partition to which the software was installed was not accessible. Disk manager shows that it's there, but doesn't show type, if it's healthy and gives me an error when trying to read its properties. The problem seems to be common after power loss, people recommend solving it by assigning a letter to the partition via DiskPart utility, but partition isn't listed in my case. I can access that partition with bootable OSs (like bootable Ubuntu or winXP) and all the files are there, but another installation of Windows 7 gives me the same results as the original. I could just copy all data to another disk if there was enough space, but unfortunately the size of partition I'm having problems with is 1.1TB. How do I regain access to the partition in my original Windows 7 installation without losing any data?

    Read the article

  • Computer only booting after POWER ON/OFF 10 times or more?

    - by Jan Gressmann
    Hi fellow geeks, recently my computer started to behave like an old car and won't start up anymore unless I flip the power switch repeatedly. What happens when I power it on: CPU fans spins briefly and very slowly, then it stops Same with GPU fan No BIOS beeps or HDD activity Screen stays black After turning it on and off for like 10 times, it'll eventually boot like normal and run smooth without any problems what-so-ever. But I'm worried it might eventually die completely. Anyone know the most common cause of this? Maybe I should just leave the computer powered on? :)

    Read the article

  • Find all A^x in a given range

    - by Austin Henley
    I need to find all monomials in the form AX that when evaluated falls within a range from m to n. It is safe to say that the base A is greater than 1, the power X is greater than 2, and only integers need to be used. For example, in the range 50 to 100, the solutions would be: 2^6 3^4 4^3 My first attempt to solve this was to brute force all combinations of A and X that make "sense." However this becomes too slow when used for very large numbers in a big range since these solutions are used in part of much more intensive processing. Here is the code: def monoSearch(min, max): base = 2 power = 3 while 1: while base**power < max: if base**power > min: print "Found " + repr(base) + "^" + repr(power) + " = " + repr(base**power) power = power + 1 base = base + 1 power = 3 if base**power > max: break I could remove one base**power by saving the value in a temporary variable but I don't think that would make a drastic effect. I also wondered if using logarithms would be better or if there was a closed form expression for this. I am open to any optimizations or alternatives to finding the solutions.

    Read the article

  • Open XML SDK 2.0 - Split table to new power point slide when content flows off current slide

    - by amurra
    I have a bunch of data that I need to export from a website to a power point presentation and have been using Open XML SDK 2.0 to perform this task. I have a power point presentation that I am putting through Open XML SDK 2.0 Productivity Tool to generate the template code that I can use to recreate the export. On one of those slides I have a table and the requirement is to add data to that table and break that table across multiple slides if the table exceeds the bottom of the slide. The approach I have taken is to determine the height of the table and if it exceeds the height of the slide, move that new content into the next slide. I have read Bryan and Jones blog on adding repeating data to a power point slide, but my scenario is a little different. They use the following code: A.Table tbl = current.Slide.Descendants<A.Table>().First(); A.TableRow tr = new A.TableRow(); tr.Height = heightInEmu; tr.Append(CreateDrawingCell(imageRel + imageRelId)); tr.Append(CreateTextCell(category)); tr.Append(CreateTextCell(subcategory)); tr.Append(CreateTextCell(model)); tr.Append(CreateTextCell(price.ToString())); tbl.Append(tr); imageRelId++; This won't work for me since they know what height to set the table row to since it will be the height of the image, but when adding in different amounts of text I do not know the height ahead of time so I just set tr.Heightto a default value. Here is my attempt at figuring at the table height: A.Table tbl = tableSlide.Slide.Descendants<A.Table>().First(); A.TableRow tr = new A.TableRow(); tr.Height = 370840L; tr.Append(PowerPointUtilities.CreateTextCell("This"); tr.Append(PowerPointUtilities.CreateTextCell("is")); tr.Append(PowerPointUtilities.CreateTextCell("a")); tr.Append(PowerPointUtilities.CreateTextCell("test")); tr.Append(PowerPointUtilities.CreateTextCell("Test")); tbl.Append(tr); tableSlide.Slide.Save(); long tableHeight = PowerPointUtilities.TableHeight(tbl); Here are the helper methods: public static A.TableCell CreateTextCell(string text) { A.TableCell tableCell = new A.TableCell( new A.TextBody(new A.BodyProperties(), new A.Paragraph(new A.Run(new A.Text(text)))), new A.TableCellProperties()); return tableCell; } public static Int64Value TableHeight(A.Table table) { long height = 0; foreach (var row in table.Descendants<A.TableRow>() .Where(h => h.Height.HasValue)) { height += row.Height.Value; } return height; } This correctly adds the new table row to the existing table, but when I try and get the height of the table, it returns the original height and not the new height. The new height meaning the default height I initially set and not the height after a large amount of text has been inserted. It seems the height only gets readjusted when it is opened in power point. I have also tried accessing the height of the largest table cell in the row, but can't seem to find the right property to perform that task. My question is how do you determine the height of a dynamically added table row since it doesn't seem to update the height of the row until it is opened in power point? Any other ways to determine when to split content to another slide while using Open XML SDK 2.0? I'm open to any suggestion on a better approach someone might have taken since there isn't much documentation on this subject.

    Read the article

  • Help me understand why page sizes are a power of 2?

    - by eric
    Answer I need help with is: Recall that paging is implemented by breaking up an address into a page and offset number. It is most efficient to break the address into X page bits and Y offset bits, rather than perform arithmetic on the address to calculate the page number and offset. Because each bit position represents a power of 2, splitting an address between bits results in a page size that is a power of 2. i don't quite understand this answer, can anyone give a simpler explanation?

    Read the article

< Previous Page | 70 71 72 73 74 75 76 77 78 79 80 81  | Next Page >