Search Results

Search found 14311 results on 573 pages for 'stan note'.

Page 75/573 | < Previous Page | 71 72 73 74 75 76 77 78 79 80 81 82  | Next Page >

  • Building Visual Studio Setup Projects with TFS 2010 Team Build

    - by Jakob Ehn
    One of the most common complaints from people starting to use Team Build is that is doesn’t support building Microsoft’s own Setup and Deployment project (*.vdproj). When creating a default build definition that compiles a solution containing a setup project, you’ll get the following warning: The project file "MyProject.vdproj" is not supported by MSBuild and cannot be built.   This is what the problem is all about. MSBuild, that is used for compiling your projects, does not understand the proprietary vdproj format defined by Microsoft quite some time ago. Unfortunately there is no sign that this will change in the near future, in fact the setup projects has barely changed at all since they were introduced. VS 2010 brings no new features or improvements hen it comes to the setup projects. VS 2010 does include a limited version of InstallShield which promises to be more MSBuild friendly and with more or less the same features as VS setup projects. I hope to get a closer look at this installer project type soon. But, how do we go about to build a Visual Studio setup project and produce an MSI as part of a Team Build process? Well, since only one application known to man understands the vdproj projects, we will have to installa copy of Visual Studio on the build server. Sad but true. After doing this, we use the Visual Studio command line interface (devenv) to perform the build. In this post I will show how to do this by using the InvokeProcess activity directly in a build workflow template. You’ll want to run build your setup projects after you have successfully compiled the projects.   Install Visual Studio 2010 on the build server(s)   Open your build process template /remember to branch or copy the xaml file before modifying it!)   Locate the Try to Compile the Project activity   Drop an instance of the InvokeProcess activity from the toolbox onto the designer, after the Run MSBuild for Project activity   Drop an instance of the WriteBuildMessage activity inside the Handle Standard Output section. Set the Importance property to Microsoft.TeamFoundation.Build.Client.BuildMessageImportance.High (NB: This is necessary if you want the output from devenv to show up in the build log when running the build with the default verbosity) Set the Message property to stdOutput   Drop an instance of the WriteBuildError activity to the Handle Error Output section Set the Message property to errOutput   Select the InvokeProcess activity and set the values of the parameters to:     The finished workflow should look like this:     This will generate the MSI files, but they won’t be copied to the drop location. This is because we are using devenv and not MSBuild, so we have to do this explicitly   Drop a Sequence activity somewhere after the Copy to Drop location activity.   Create a variable in the Sequence activity of type IEnumerable<String> and call it GeneratedInstallers   Drop a FindMatchingFiles activity in the sequence activity and set the properties to:     Drop a ForEach<String> activity after the FindMatchingFiles activity. Set the Value property to GeneratedInstallers   Drop an InvokeProcess activity inside the ForEach activity.  FileName: “xcopy.exe” Arguments: String.Format("""{0}"" ""{1}""", item, BuildDetail.DropLocation) The Sequence activity should look like this:     Save the build process template and check it in.   Run the build and verify that the MSI’s is built and copied to the drop location.   Note 1: One of the drawback of using devenv like this in a team build is that since all the output from the default compilations is placed in the Binaries folder, the outputs is not avaialable when devenv is invoked, which causes the whole solution to rebuild again. In TFS 2008, this was pretty simple to fix by using the CustomizableOutDir property. In TFS 2010, the same feature is not avaialble. Jim Lamb blogged about this recently, have a look at it if you have a problem with this: http://blogs.msdn.com/jimlamb/archive/2010/04/13/customizableoutdir-in-tfs-2010.aspx   Note 2: Although the above solution works, a better approach is to wrap this in a custom activity that you can use in your builds. I will come back to this in a future post.

    Read the article

  • What is the Oracle Utilities Application Framework?

    - by Anthony Shorten
    The Oracle Utilities Application Framework is a reusable, scalable and flexible java based framework which allows other products to be built, configured and implemented in a standard way. Note: Even though the Framework is built in java it can be integrated with COBOL based extensions for backward compatibility. When Oracle Utilities Customer Care & Billing was migrated from V1 to V2, it was decided that the technical aspects of that product be separated to allow for reuse and independence from technical issues. The idea was that all the technical aspects would be concentrated in this separate product (i.e. a framework) and allow all products using the framework to concentrate on delivering superior functionality. The product was named the Oracle Utilities Application Framework (oufw is the product code). The technical components are contained in the Oracle Utilities Application Framework which can be summarized as follows: Metadata - The Oracle Utilities Application Framework is responsible for defining and using the metadata to define the runtime behavior of the product. All the metadata definition and management is contained within the Oracle Utilities Application Framework. UI Management - The Oracle Utilities Application Framework is responsible for defining and rendering the pages and responsible for ensuring the pages are in the appropriate format for the locale. Integration - The Oracle Utilities Application Framework is responsible for providing the integration points to the architecture. Refer to the Oracle Utilities Application Framework Integration Overview for more details Tools - The Oracle Utilities Application Framework provides a common set of facilities and tools that can be used across all products. Technology - The Oracle Utilities Application Framework is responsible for all technology standards compliance, platform support and integration. There are a number of products from the Tax and Utilities Global Business Unit as well as from the Financial Services Global Business Unit that are built upon the Oracle Utilities Application Framework. These products require the Oracle Utilities Application Framework to be installed first and then the product itself installed onto the framework to complete the installation process. There are a number of key benefits that the Oracle Utilities Application Framework provides to these products: Common facilities - The Oracle Utilities Application Framework provides a standard set of technical facilities that mean that products can concentrate in the unique aspects of their markets rather than making technical decisions. Common methods of configuration - The Oracle Utilities Application Framework standardizes the technical configuration process for a product. Customers can effectively reuse the configuration process across products. Multi-lingual and Multi-platform - The Oracle Utilities Application Framework allows the products to be offered in more markets and across multiple platforms for maximized flexibility. Common methods of implementation - The Oracle Utilities Application Framework standardizes the technical aspects of a product implementation. Customers can effectively reuse the technical implementation process across products. Quicker adoption of new technologies - As new technologies and standards are identified as being important for the product line, they can be integrated centrally benefiting multiple products. Cross product reuse - As enhancements to the Oracle Utilities Application Framework are identified by a particular product, all products can potentially benefit from the enhancement. Note: Use of the Oracle Utilities Application Framework does not preclude the introduction of product specific technologies or facilities to satisfy market needs. The framework minimizes the need and assists in the quick integration of a new product specific piece of technology (if necessary). The Framework is not available as a product itself and is bundled with Tax and Utilities Global Business Unit prodicts. At the present time the following products are on the Framework: Oracle Utilities Customer Care And Billing (V2 and above) Oracle Enterprise Taxation Management (V2 and above) Oracle Utilities Business Intelligence (V2 and above) Oracle Utilities Mobile Workforice Management (V2 and above)

    Read the article

  • SQL SERVER – SHRINKFILE and TRUNCATE Log File in SQL Server 2008

    - by pinaldave
    Note: Please read the complete post before taking any actions. This blog post would discuss SHRINKFILE and TRUNCATE Log File. The script mentioned in the email received from reader contains the following questionable code: “Hi Pinal, If you could remember, I and my manager met you at TechEd in Bangalore. We just upgraded to SQL Server 2008. One of our jobs failed as it was using the following code. The error was: Msg 155, Level 15, State 1, Line 1 ‘TRUNCATE_ONLY’ is not a recognized BACKUP option. The code was: DBCC SHRINKFILE(TestDBLog, 1) BACKUP LOG TestDB WITH TRUNCATE_ONLY DBCC SHRINKFILE(TestDBLog, 1) GO I have modified that code to subsequent code and it works fine. But, are there other suggestions you have at the moment? USE [master] GO ALTER DATABASE [TestDb] SET RECOVERY SIMPLE WITH NO_WAIT DBCC SHRINKFILE(TestDbLog, 1) ALTER DATABASE [TestDb] SET RECOVERY FULL WITH NO_WAIT GO Configuration of our server and system is as follows: [Removed not relevant data]“ An email like this that suddenly pops out in early morning is alarming email. Because I am a dead, busy mind, so I had only one min to reply. I wrote down quickly the following note. (As I said, it was a single-minute email so it is not completely accurate). Here is that quick email shared with all of you. “Hi Mr. DBA [removed the name] Thanks for your email. I suggest you stop this practice. There are many issues included here, but I would list two major issues: 1) From the setting database to simple recovery, shrinking the file and once again setting in full recovery, you are in fact losing your valuable log data and will be not able to restore point in time. Not only that, you will also not able to use subsequent log files. 2) Shrinking file or database adds fragmentation. There are a lot of things you can do. First, start taking proper log backup using following command instead of truncating them and losing them frequently. BACKUP LOG [TestDb] TO  DISK = N'C:\Backup\TestDb.bak' GO Remove the code of SHRINKING the file. If you are taking proper log backups, your log file usually (again usually, special cases are excluded) do not grow very big. There are so many things to add here, but you can call me on my [phone number]. Before you call me, I suggest for accuracy you read Paul Randel‘s two posts here and here and Brent Ozar‘s Post here. Kind Regards, Pinal Dave” I guess this post is very much clear to you. Please leave your comments here. As mentioned, this is a very huge subject; I have just touched a tip of the ice-berg and have tried to point to authentic knowledge. Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, SQL, SQL Authority, SQL Backup and Restore, SQL Data Storage, SQL Query, SQL Scripts, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • Search Alternative Search Engines from within Bing’s Search Page

    - by Asian Angel
    So you love using Bing Search but may still be curious to see what another search engine will provide if used. Now you can search using another search engine from within the Bing Search page and enjoy numbered results using two simple user scripts. Note: These user scripts may also be added to other browsers as well (i.e. Iron, Opera, etc.). Before Bing Search does nicely on searches but what if you would like to try the same search with another search engine? Having to manually open a new tab, navigate to the appropriate website, and then start a new search is not too convenient. Another possible frustration for some people may be knowing just how many search results that they have looked through. Well, both of these small problems are easy to fix with two wonderful user scripts. Installing the Scripts The first script that we installed (you may do either one first) was for adding alternative search engine links. Click “Install” to get started… Note: For our example we had the Greasemonkey extension installed. When the confirmation window pops up click on “Install” to finish adding the user script to Firefox. Repeating the same procedure as above add your second script to Firefox. Confirm the second user script installation and you are ready to enjoy nicer Bing Search results. After As you can see there are two small unobtrusive differences in our search results. The alternative search engine links are conveniently located at the top of the page and now you can easily know just how many search results that you have looked through. The results when we decided to try the search in a transfer over to Yahoo. Our search transferred to Ask Search. The alternative search links can be very helpful if Bing is not providing the kind of search results that you are hoping for. Still going very nicely past the 100 mark… Conclusion If you have been wanting a small booster to searching with Bing then these two scripts will get you on your way. Using Opera Browser? See our how-to for adding user scripts to Opera here. Links Install the Bing (Alternate Search Engine Links) User Script Install the Bing Numbered Search Results User Script Download the Greasemonkey extension for Firefox (Mozilla Add-ons) Download the Stylish extension for Firefox (Mozilla Add-ons) Similar Articles Productive Geek Tips Organize Your Firefox Search Engines Into FoldersFix for Slow "Instant Search" In Outlook 2007Gain Access to a Search Box in Google ChromeManage Web Searches In SafariModify Firefox’s Search Bar Behavior with SearchLoad Options TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Heaven & Hell Finder Icon Using TrueCrypt to Secure Your Data Quickly Schedule Meetings With NeedtoMeet Share Flickr Photos On Facebook Automatically Are You Blocked On Gtalk? Find out Discover Latest Android Apps On AppBrain

    Read the article

  • AIX Grid Control 10.2.0.5 Communication and Monitoring Issue since 31-DEC-2010

    - by jayatheertha.rao(at)oracle.com
    Detailed symptoms for Oracle Management Server (OMS) 10.2.0.5 on AIX Oracle Management Service 10.2.0.5 instances on AIX 5L remain active and functional, but the OMS instances fail to communicate with the Grid Control Management Agents.An SSLPeerUnverified exception will be reported in the file $ORACLE_HOME/sysman/log/emoms.trc when OMS attempts to connect with an Agent:Javax.net.ssl.SSLPeerUnverifiedException: peer not authenticatedat com.sun.net.ssl.internal.ssl.SSLSessionImpl.getPeerCertificateChain(DashoA12275)at oracle.sysman.emSDK.emd.comm.EMDClient.authenticateHTTPConnection(EMDClient.java:2002)at oracle.sysman.emSDK.emd.comm.EMDClient.getConnection(EMDClient.java:1877)at oracle.sysman.emSDK.emd.comm.EMDClient.getConnection(EMDClient.java:1810)at oracle.sysman.emSDK.emd.comm.EMDClient.verifyHttpConnection(EMDClient.java:2540)at oracle.sysman.emSDK.emd.comm.EMDClient.getResponseForRequest(EMDClient.java:2323)at oracle.sysman.emSDK.emd.comm.EMDClient.getUploadManagerStatus(EMDClient.java:4853)at oracle.sysman.eml.admin.rep.emdConfig.EmdConfigTargetsData.getEmdUploadData(EmdConfigTargetsData.java:1640)at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method)This error may be reported when:- Accessing the Agent home page in Grid Control- Setting preferred credentials for a target monitored by the Agent- Managing metrics for a target monitored by the Agent The jobs scheduled to be run by Agents can become non-responsiveThe OMS log file $ORACLE_HOME/sysman/log/emoms.trc can show:2010-12-31 00:06:58,204 [JobWorker 430:Thread-34] DEBUG emSDK.comm getStreamResponse.4015 - oracle.sysman.emSDK.emd.comm.CommException: java.io.IOException: javax.net.ssl.SSLPeerUnverifiedException: peer not authenticatedoracle.sysman.emSDK.emd.comm.CommException: java.io.IOException: javax.net.ssl.SSLPeerUnverifiedException: peer not authenticatedat oracle.sysman.emSDK.emd.comm.EMDClient.getStreamResponse_(EMDClient.java:4088)at oracle.sysman.emSDK.emd.comm.EMDClient.getStreamResponse(EMDClient.java:4009)at oracle.sysman.emSDK.emd.comm.EMDClient.remoteOperation(EMDClient.java:3404)at oracle.sysman.emdrep.jobs.CommandManager.requestRemoteCommand(CommandManager.java:765)at oracle.sysman.emdrep.jobs.commands.RemoteOp.executeCommand(RemoteOp.java:434)at oracle.sysman.emdrep.jobs.commands.RemoteOp.executeCommand(RemoteOp.java:491)at oracle.sysman.emdrep.jobs.BaseJobWorker.runStep(BaseJobWorker.java:614)at oracle.sysman.emdrep.jobs.BaseJobWorker.doOneOperation(BaseJobWorker.java:738)at oracle.sysman.emdrep.jobs.JobWorker.doOneOperation(JobWorker.java:306)at oracle.sysman.emdrep.jobs.JobWorker.run(JobWorker.java:288)at oracle.sysman.util.threadPoolManager.WorkerThread.run(Worker.java:261) Detailed symptoms for Grid Control Management Agent 10.2.0.5 on AIX Beginning 31-DEC-2010 00:00:00, 10.2.0.5 Management Agents running on the AIX 5L operating system will fail to monitor Oracle Application Server targets. As a result, the Availability Status for the Oracle Application Server targets will be in the "Metric Error" state. NOTE: The 10.2.0.5.0 Agents would experience these errors regardless of the version/platform of the OMS.The following metric error is seen in the console for the Oracle Application Server targets monitored by a Grid Control Management Agent 10.2.0.5 installed on AIX and experiencing a Root Certificate Authority issue:Message oracle.sysman.emSDK.emd.fetchlet.FetchletException: oracle.sysman.emSDK.emd.fetchlet.FetchletException: oracle.sysman.emSDK.emd.fetchlet.FetchletException: oracle.sysman.emSDK.emd.comm.CommException: java.io.IOException: javax.net.ssl.SSLPeerUnverifiedException: peer not authenticated The Grid Control Management Agent log file $ORACLE_HOME/sysman/log/emagentfetchlet.log (or $ORACLE_HOME/hostname/sysman/log/emagentfetchlet.log for a clustered Agent) includes the following errors:2010-12-31 00:01:03,626 [nmefmgr_getJNIFetchlet] ERROR ias.ResponseMetric getResponseMetric.154 - Unable tocompute application server statusoracle.sysman.emSDK.emd.fetchlet.FetchletException: oracle.sysman.emSDK.emd.comm.CommException: java.io.IOException: javax.net.ssl.SSLPeerUnverifiedException: peer not authenticatedat oracle.sysman.ias.ias.ResponseMetric.getResponseMetric(ResponseMetric.java:108)at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method)at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:79)at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:43)at java.lang.reflect.Method.invoke(Method.java:618)at oracle.sysman.emd.fetchlets.JavaWrapperFetchlet.getMetric(JavaWrapperFetchlet.java:217)at oracle.sysman.emd.fetchlets.FetchletWrapper.getMetric(FetchletWrapper.java:382) Beginning 31-DEC-2010, 10.2.0.5 Management Agents on the AIX 5L platform will fail to secure or re-secure with Oracle Management Service (OMS). This failure will cause installation of 10.2.0.5 Agents on the AIX 5L platform to fail.NOTE: The 10.2.0.5.0 Agents would experience these errors regardless of the version/platform of the OMS.The "emctl secure agent" command will fail with the following error, which will be written to the $ORACLE_HOME/sysman/log/secure.log file (or $ORACLE_HOME/hostname/sysman/log/secure.log for a clustered Agent) :2011-01-03 21:06:11,941 [main] ERROR agent.SecureAgentCmd main.207 - Failedto secure the Agent:javax.net.ssl.SSLPeerUnverifiedException: peer not authenticatedatcom.sun.net.ssl.internal.ssl.SSLSessionImpl.getPeerCertificateChain(DashoA6275)atoracle.sysman.emctl.secure.agent.SecureAgentCmd.checkUpload(SecureAgentCmd.java:478)atoracle.sysman.emctl.secure.agent.SecureAgentCmd.secureAgent(SecureAgentCmd.java:249)atoracle.sysman.emctl.secure.agent.SecureAgentCmd.main(SecureAgentCmd.java:200)  For solution, refer to AIX Grid Control 10.2.0.5 SSL Communication and Monitoring Issue since 31-DEC-2010 (Doc ID 1275070.1)

    Read the article

  • A basic T4 template for generating Model Metadata in ASP.NET MVC2

    - by rajbk
    I have been learning about T4 templates recently by looking at the awesome ADO.NET POCO entity generator. By using the POCO entity generator template as a base, I created a T4 template which generates metadata classes for a given Entity Data Model. This speeds coding by reducing the amount of typing required when creating view specific model and its metadata. To use this template, Download the template provided at the bottom. Set two values in the template file. The first one should point to the EDM you wish to generate metadata for. The second is used to suffix the namespace and classes that get generated. string inputFile = @"Northwind.edmx"; string suffix = "AutoMetadata"; Add the template to your MVC 2 Visual Studio 2010 project. Once you add it, a number of classes will get added to your project based on the number of entities you have.    One of these classes is shown below. Note that the DisplayName, Required and StringLength attributes have been added by the t4 template. //------------------------------------------------------------------------------ // <auto-generated> // This code was generated from a template. // // Changes to this file may cause incorrect behavior and will be lost if // the code is regenerated. // </auto-generated> //------------------------------------------------------------------------------   using System; using System.ComponentModel; using System.ComponentModel.DataAnnotations;   namespace NorthwindSales.ModelsAutoMetadata { public partial class CustomerAutoMetadata { [DisplayName("Customer ID")] [Required] [StringLength(5)] public string CustomerID { get; set; } [DisplayName("Company Name")] [Required] [StringLength(40)] public string CompanyName { get; set; } [DisplayName("Contact Name")] [StringLength(30)] public string ContactName { get; set; } [DisplayName("Contact Title")] [StringLength(30)] public string ContactTitle { get; set; } [DisplayName("Address")] [StringLength(60)] public string Address { get; set; } [DisplayName("City")] [StringLength(15)] public string City { get; set; } [DisplayName("Region")] [StringLength(15)] public string Region { get; set; } [DisplayName("Postal Code")] [StringLength(10)] public string PostalCode { get; set; } [DisplayName("Country")] [StringLength(15)] public string Country { get; set; } [DisplayName("Phone")] [StringLength(24)] public string Phone { get; set; } [DisplayName("Fax")] [StringLength(24)] public string Fax { get; set; } } } The gen’d class can be used from your project by creating a partial class with the entity name and setting the MetadataType attribute.namespace MyProject.Models{ [MetadataType(typeof(CustomerAutoMetadata))] public partial class Customer { }} You can also copy the code in the metadata class generated and create your own ViewModel class. Note that the template is super basic  and does not take into account complex properties. I have tested it with the Northwind database. This is a work in progress. Feel free to modify the template to suite your requirements. Standard disclaimer follows: Use At Your Own Risk, Works on my machine running VS 2010 RTM/ASP.NET MVC 2 AutoMetaData.zip Mr. Incredible: Of course I have a secret identity. I don't know a single superhero who doesn't. Who wants the pressure of being super all the time?

    Read the article

  • Convert YouTube Videos to MP3 with YouTube Downloader

    - by DigitalGeekery
    Are you looking for a way to take the music videos you watch on YouTube and convert them to MP3? Today we take a look at an easy way to convert those YouTube videos to MP3 for free with YouTube Downloader. The YouTube Downloader functions in two steps. First, it downloads the video from YouTube in MP4 format, and then allows you to convert that MP4 file to MP3. Note: It also supports conversion conversion to some other formats such as AVI video, MOV, iPhone, PSP, 3GP, and WMV.   Installation and usage Download and Install YouTube Downloader. (See download link below) Open the YouTube Downloader by clicking on the desktop icon. Find a YouTube video you’d like to convert to MP3 and copy the URL. Paste the URL into the “Enter video URL” text box in YouTube Downloader. When you hover your mouse over the text box, the text box will auto-fill with the URL from your clipboard. Select the “Download video from YouTube” radio button and click “Ok.” Choose a folder to location to download your YouTube video and click “Save.” The video is downloaded in MP4 format. Now wait while the video is downloaded to your hard drive.   Select the “Convert video (previously downloaded) from file” radio button. Click the (…) button to the right of the “Select video file” text box to browse for and select the MP4 file you just downloaded. Then select “MPEG Audio Layer (MP3) from the “Convert to” drop down list. Select “OK” to begin the conversion. Choose the conversion quality by moving the slider to the right or left. The options are: Low (96kbps bite rate), Medium (128kbps bit rate), Optimal (192kbps bit rate), and High 256kbps bit rate). Here you can select the output volume as well. Click “OK” when finished. If there is a portion of the beginning or end of the video that you wish to cut out of the MP3, select the “Cut video” check box and choose a Start and End time. Click “OK” when finished. Note: The start and end time represent the audio portion of the MP3 you wish to keep. All portions before and after these times will be cut.   The conversion process will begin and should only take a few moments. Times will vary depending on the size of the video you’re converting. Conversion was successful! The MP3 you converted will be in the same directory you downloaded the video to. Now you’re ready to listen to your MP3 or import it to your Zune, iTunes, or music library. You may also want to delete the MP4 files after the conversion if you will no longer need them. Conclusion YouTube Downloader features a very simple interface that’s user friendly and easy to use. It comes in handy when you watch videos that look horrible, but the sound quality is good. Or if you just need to hear the audio of something posted and don’t need the video. It also allows you to download from Google Video, MySpace, and others. Download YouTube Downloader Similar Articles Productive Geek Tips Download YouTube Videos with Cheetah YouTube DownloaderWatch YouTube Videos in Cinema Style in FirefoxStop YouTube Videos from Automatically Playing in FirefoxRemove Unsuitable Comments from YouTubeImprove YouTube Video Viewing in Google Chrome TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 PCmover Professional Windows Media Player 12: Tweak Video & Sound with Playback Enhancements Own a cell phone, or does a cell phone own you? Make your Joomla & Drupal Sites Mobile with OSMOBI Integrate Twitter and Delicious and Make Life Easier Design Your Web Pages Using the Golden Ratio Worldwide Growth of the Internet

    Read the article

  • Failling install Ralink RT5592 driver on Ubuntu 14.04 LTS

    - by atisou
    My problem concerns the installation of a wi-fi driver (RT5592) for my new wi-fi adapter (PCE-N53) on my newly built computer. Basically, I don't manage to get the driver installed and therefore I cannot get the wifi to work. I know I am not the only one having this issue this year, between RT5592 driver and Ubuntu 14.04 LTS, in one way or the other. Is there anybody who has ever been able to fix this problem? It does not look like on all the posts I have been through... Following an answer to a same problem as mine (I was getting the same error message as Christopher Kyle Horton of "incompatible types" etc), I have applied the instructions and done the editings in a script as suggested by Paul B. Unfortunately I still do get error/warnings message (a different one this time) at the end of the make and the wi-fi still does not work. Below is a snapshot of the end of the message: In file included from /home/username/Downloads/PCE-N53/Linux/DPO_GPL_RT5592STA_LinuxSTA_v2.6.0.0_20120326/include/os/rt_linux.h:31:0, from /home/username/Downloads/PCE-N53/Linux/DPO_GPL_RT5592STA_LinuxSTA_v2.6.0.0_20120326/include/rtmp_os.h:44, from /home/username/Downloads/PCE-N53/Linux/DPO_GPL_RT5592STA_LinuxSTA_v2.6.0.0_20120326/include/rtmp_comm.h:69, from /home/username/Downloads/PCE-N53/Linux/DPO_GPL_RT5592STA_LinuxSTA_v2.6.0.0_20120326/os/linux/../../os/linux/pci_main_dev.c:31: include/linux/module.h:88:32: error: ‘__mod_pci_device_table’ aliased to undefined symbol ‘rt2860_pci_tbl’ extern const struct gtype##_id __mod_##gtype##_table \ ^ include/linux/module.h:146:3: note: in expansion of macro ‘MODULE_GENERIC_TABLE’ MODULE_GENERIC_TABLE(type##_device,name) ^ /home/username/Downloads/PCE-N53/Linux/DPO_GPL_RT5592STA_LinuxSTA_v2.6.0.0_20120326/os/linux/../../os/linux/pci_main_dev.c:73:1: note: in expansion of macro ‘MODULE_DEVICE_TABLE’ MODULE_DEVICE_TABLE(pci, rt2860_pci_tbl); ^ cc1: some warnings being treated as errors make[2]: *** [/home/username/Downloads/PCE-N53/Linux/DPO_GPL_RT5592STA_LinuxSTA_v2.6.0.0_20120326/os/linux/../../os/linux/pci_main_dev.o] Error 1 make[1]: *** [_module_/home/username/Downloads/PCE-N53/Linux/DPO_GPL_RT5592STA_LinuxSTA_v2.6.0.0_20120326/os/linux] Error 2 make[1]: Leaving directory `/usr/src/linux-headers-3.13.0-32-generic' make: *** [LINUX] Error 2 The full pastebin data: paste.ubuntu.com/8088834/ It looks from the message that one would need to edit manually some of/other scripts in the driver package, as did Paul B suggest in one case. But I have no idea how to do that. Here is the driver package of the wifi adapter: www.asus.com/uk/Networking/PCEN53/HelpDesk_Download/ My system is as following: OS: ubuntu 14.04 LTS wi-fi card: Asus PCE-N53 motherboard: Asus KCMA-D8 processor: AMD Opteron 4228 HE kernel: 3.13.0-32-generic Following this info from chili555 in here, below are some extra info about my system: lspci -nn | grep 0280 gives 04:00.0 Network controller [0280]: Ralink corp. RT5592 PCI2 Wireless Network Adapater [1814:5592] and sudo apt-get install linux-headers-generic returns linux-headers-generic is already the newest version. 0 upgraded, 0 newly installed, 0 to remove and 0 not upgraded. If this is a kernel version (I have 3.13.0-32-generic) incompatibility issue with the driver as chilli555 suggests (the README file in the driver package says indeed it is compatible with kernel 2.6), how could one trick this around to make it work? that should be possible right? On ubuntu forums, the patches proposed dont work (leads the computer to freeze). Basically: is there anybody out there who has ever been able to make a PCE-N53 work on Ubuntu 14.04 LTS (kernel 3.13)? how shall I edit the driver package to make it work for my kernel?

    Read the article

  • The Beginner’s Guide to Greasemonkey User Scripts in Firefox

    - by Asian Angel
    Everybody knows that Firefox has add-ons for virtually everything, but if you don’t want to bloat your installation you’ve always got the option of Greasemonkey scripts instead. Here’s a quick primer on how to use them. Getting Started with User Scripts Once you have Greasemonkey installed, managing the extension is really easy. Left click on the status bar icon to turn the extension on/off and right click to access the context menu shown here. Whether you use the Options button in the Add-ons Manager Window or the context menu shown above, both will bring up the Manage User Scripts dialog. At the moment you have a nice clean slate to work with… time to get some scripts added in. The majority of user scripts can be found at two different sites, the first being appropriately named userscripts.org, and you can either browse by tag or search for a script. As you can see here your search for a particular type of script can be quickly narrowed down based on category. There is definitely a lot to choose from. For our example we focused on the “textarea” tag. There were 62 scripts available but we quickly found what we were looking for on the first page. Installing, Managing, & Using Your Scripts When you find a script that you want to install visit the script’s homepage and click on the “Install” button. Note: Link for this script provided below. Once you have clicked on the Install button, Greasemonkey will open up the following installation window. You will be able to view: A summary of what the script does A list of websites that the script is supposed to function on (our example is set for all) View the script source if desired Make a final decision on whether to install the script or cancel the process Right-clicking on our status bar icon shows our new script listed and active. Reopening the Manage User Scripts window shows: Our new script listed in the column on the left The websites/pages included An option to disable the script (can also be done in the context menu) The ability to edit the script The ability to uninstall the script If you choose to edit the script you will be asked to browse for and select a default text editor of your choice (first time only). Once you have selected a text editor you can make any changes desired to the script. We decided to test our new user script on the site. Going to the comment box at the bottom we could easily resize the window as desired. The Comment box definitely got a lot bigger. Conclusion If you prefer to keep the number of extensions to a minimum in your Firefox installation then Greasemonkey and the Userscripts website can easily provide that extra functionality without the bloat. For added auto website script detection goodness see our article on Greasefire. Note: See our article here for specialized How-To Geek User Style Scripts that can be added to Greasemonkey. Links Download the Greasemonkey Extension (Mozilla Add-ons) Install the Textarea & Input Resize User Script Visit the Userscripts.org Website Visit the Userstyles.org Website Similar Articles Productive Geek Tips Enjoy How-To Geek User Style Script GoodnessEnable Multi-Column Google Searches with a User ScriptSearch Alternative Search Engines from within Bing’s Search PageFind User Scripts for Your Favorite Websites the Easy WaySet Up User Scripts in Opera Browser TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Office 2010 reviewed in depth by Ed Bott FoxClocks adds World Times in your Statusbar (Firefox) Have Fun Editing Photo Editing with Citrify Outlook Connector Upgrade Error Gadfly is a cool Twitter/Silverlight app Enable DreamScene in Windows 7

    Read the article

  • SQL SERVER – Attach mdf file without ldf file in Database

    - by pinaldave
    Background Story: One of my friends recently called up and asked me if I had spare time to look at his database and give him a performance tuning advice. Because I had some free time to help him out, I said yes. I asked him to send me the details of his database structure and sample data. He said that since his database is in a very early stage and is small as of the moment, so he told me that he would like me to have a complete database. My response to him was “Sure! In that case, take a backup of the database and send it to me. I will restore it into my computer and play with it.” He did send me his database; however, his method made me write this quick note here. Instead of taking a full backup of the database and sending it to me, he sent me only the .mdf (primary database file). In fact, I asked for a complete backup (I wanted to review file groups, files, as well as few other details).  Upon calling my friend,  I found that he was not available. Now,  he left me with only a .mdf file. As I had some extra time, I decided to checkout his database structure and get back to him regarding the full backup, whenever I can get in touch with him again. Technical Talk: If the database is shutdown gracefully and there was no abrupt shutdown (power outrages, pulling plugs to machines, machine crashes or any other reasons), it is possible (there’s no guarantee) to attach .mdf file only to the server. Please note that there can be many more reasons for a database that is not getting attached or restored. In my case, the database had a clean shutdown and there were no complex issues. I was able to recreate a transaction log file and attached the received .mdf file. There are multiple ways of doing this. I am listing all of them here. Before using any of them, please consult the Domain Expert in your company or industry. Also, never attempt this on live/production server without the presence of a Disaster Recovery expert. USE [master] GO -- Method 1: I use this method EXEC sp_attach_single_file_db @dbname='TestDb', @physname=N'C:\Program Files\Microsoft SQL Server\MSSQL10.MSSQLSERVER\MSSQL\DATA\TestDb.mdf' GO -- Method 2: CREATE DATABASE TestDb ON (FILENAME = N'C:\Program Files\Microsoft SQL Server\MSSQL10.MSSQLSERVER\MSSQL\DATA\TestDb.mdf') FOR ATTACH_REBUILD_LOG GO Method 2: If one or more log files are missing, they are recreated again. There is one more method which I am demonstrating here but I have not used myself before. According to Book Online, it will work only if there is one log file that is missing. If there are more than one log files involved, all of them are required to undergo the same procedure. -- Method 3: CREATE DATABASE TestDb ON ( FILENAME = N'C:\Program Files\Microsoft SQL Server\MSSQL10.MSSQLSERVER\MSSQL\DATA\TestDb.mdf') FOR ATTACH GO Please read the Book Online in depth and consult DR experts before working on the production server. In my case, the above syntax just worked fine as the database was clean when it was detached. Feel free to write your opinions and experiences for it will help the IT community to learn more from your suggestions and skills. Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, Readers Question, SQL, SQL Authority, SQL Backup and Restore, SQL Data Storage, SQL Query, SQL Scripts, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • MySQL Syslog Audit Plugin

    - by jonathonc
    This post shows the construction process of the Syslog Audit plugin that was presented at MySQL Connect 2012. It is based on an environment that has the appropriate development tools enabled including gcc,g++ and cmake. It also assumes you have downloaded the MySQL source code (5.5.16 or higher) and have compiled and installed the system into the /usr/local/mysql directory ready for use.  The information provided below is designed to show the different components that make up a plugin, and specifically an audit type plugin, and how it comes together to be used within the MySQL service. The MySQL Reference Manual contains information regarding the plugin API and how it can be used, so please refer there for more detailed information. The code in this post is designed to give the simplest information necessary, so handling every return code, managing race conditions etc is not part of this example code. Let's start by looking at the most basic implementation of our plugin code as seen below: /*    Copyright (c) 2012, Oracle and/or its affiliates. All rights reserved.    Author:  Jonathon Coombes    Licence: GPL    Description: An auditing plugin that logs to syslog and                 can adjust the loglevel via the system variables. */ #include <stdio.h> #include <string.h> #include <mysql/plugin_audit.h> #include <syslog.h> There is a commented header detailing copyright/licencing and meta-data information and then the include headers. The two important include statements for our plugin are the syslog.h plugin, which gives us the structures for syslog, and the plugin_audit.h include which has details regarding the audit specific plugin api. Note that we do not need to include the general plugin header plugin.h, as this is done within the plugin_audit.h file already. To implement our plugin within the current implementation we need to add it into our source code and compile. > cd /usr/local/src/mysql-5.5.28/plugin > mkdir audit_syslog > cd audit_syslog A simple CMakeLists.txt file is created to manage the plugin compilation: MYSQL_ADD_PLUGIN(audit_syslog audit_syslog.cc MODULE_ONLY) Run the cmake  command at the top level of the source and then you can compile the plugin using the 'make' command. This results in a compiled audit_syslog.so library, but currently it is not much use to MySQL as there is no level of api defined to communicate with the MySQL service. Now we need to define the general plugin structure that enables MySQL to recognise the library as a plugin and be able to install/uninstall it and have it show up in the system. The structure is defined in the plugin.h file in the MySQL source code.  /*   Plugin library descriptor */ mysql_declare_plugin(audit_syslog) {   MYSQL_AUDIT_PLUGIN,           /* plugin type                    */   &audit_syslog_descriptor,     /* descriptor handle               */   "audit_syslog",               /* plugin name                     */   "Author Name",                /* author                          */   "Simple Syslog Audit",        /* description                     */   PLUGIN_LICENSE_GPL,           /* licence                         */   audit_syslog_init,            /* init function     */   audit_syslog_deinit,          /* deinit function */   0x0001,                       /* plugin version                  */   NULL,                         /* status variables        */   NULL,                         /* system variables                */   NULL,                         /* no reserves                     */   0,                            /* no flags                        */ } mysql_declare_plugin_end; The general plugin descriptor above is standard for all plugin types in MySQL. The plugin type is defined along with the init/deinit functions and interface methods into the system for sharing information, and various other metadata information. The descriptors have an internally recognised version number so that plugins can be matched against the api on the running server. The other details are usually related to the type-specific methods and structures to implement the plugin. Each plugin has a type-specific descriptor as well which details how the plugin is implemented for the specific purpose of that plugin type. /*   Plugin type-specific descriptor */ static struct st_mysql_audit audit_syslog_descriptor= {   MYSQL_AUDIT_INTERFACE_VERSION,                        /* interface version    */   NULL,                                                 /* release_thd function */   audit_syslog_notify,                                  /* notify function      */   { (unsigned long) MYSQL_AUDIT_GENERAL_CLASSMASK |                     MYSQL_AUDIT_CONNECTION_CLASSMASK }  /* class mask           */ }; In this particular case, the release_thd function has not been defined as it is not required. The important method for auditing is the notify function which is activated when an event occurs on the system. The notify function is designed to activate on an event and the implementation will determine how it is handled. For the audit_syslog plugin, the use of the syslog feature sends all events to the syslog for recording. The class mask allows us to determine what type of events are being seen by the notify function. There are currently two major types of event: 1. General Events: This includes general logging, errors, status and result type events. This is the main one for tracking the queries and operations on the database. 2. Connection Events: This group is based around user logins. It monitors connections and disconnections, but also if somebody changes user while connected. With most audit plugins, the principle behind the plugin is to track changes to the system over time and counters can be an important part of this process. The next step is to define and initialise the counters that are used to track the events in the service. There are 3 counters defined in total for our plugin - the # of general events, the # of connection events and the total number of events.  static volatile int total_number_of_calls; /* Count MYSQL_AUDIT_GENERAL_CLASS event instances */ static volatile int number_of_calls_general; /* Count MYSQL_AUDIT_CONNECTION_CLASS event instances */ static volatile int number_of_calls_connection; The init and deinit functions for the plugin are there to be called when the plugin is activated and when it is terminated. These offer the best option to initialise the counters for our plugin: /*  Initialize the plugin at server start or plugin installation. */ static int audit_syslog_init(void *arg __attribute__((unused))) {     openlog("mysql_audit:",LOG_PID|LOG_PERROR|LOG_CONS,LOG_USER);     total_number_of_calls= 0;     number_of_calls_general= 0;     number_of_calls_connection= 0;     return(0); } The init function does a call to openlog to initialise the syslog functionality. The parameters are the service to log under ("mysql_audit" in this case), the syslog flags and the facility for the logging. Then each of the counters are initialised to zero and a success is returned. If the init function is not defined, it will return success by default. /*  Terminate the plugin at server shutdown or plugin deinstallation. */ static int audit_syslog_deinit(void *arg __attribute__((unused))) {     closelog();     return(0); } The deinit function will simply close our syslog connection and return success. Note that the syslog functionality is part of the glibc libraries and does not require any external factors.  The function names are what we define in the general plugin structure, so these have to match otherwise there will be errors. The next step is to implement the event notifier function that was defined in the type specific descriptor (audit_syslog_descriptor) which is audit_syslog_notify. /* Event notifier function */ static void audit_syslog_notify(MYSQL_THD thd __attribute__((unused)), unsigned int event_class, const void *event) { total_number_of_calls++; if (event_class == MYSQL_AUDIT_GENERAL_CLASS) { const struct mysql_event_general *event_general= (const struct mysql_event_general *) event; number_of_calls_general++; syslog(audit_loglevel,"%lu: User: %s Command: %s Query: %s\n", event_general->general_thread_id, event_general->general_user, event_general->general_command, event_general->general_query ); } else if (event_class == MYSQL_AUDIT_CONNECTION_CLASS) { const struct mysql_event_connection *event_connection= (const struct mysql_event_connection *) event; number_of_calls_connection++; syslog(audit_loglevel,"%lu: User: %s@%s[%s] Event: %d Status: %d\n", event_connection->thread_id, event_connection->user, event_connection->host, event_connection->ip, event_connection->event_subclass, event_connection->status ); } }   In the case of an event, the notifier function is called. The first step is to increment the total number of events that have occurred in our database.The event argument is then cast into the appropriate event structure depending on the class type, of general event or connection event. The event type counters are incremented and details are sent via the syslog() function out to the system log. There are going to be different line formats and information returned since the general events have different data compared to the connection events, even though some of the details overlap, for example, user, thread id, host etc. On compiling the code now, there should be no errors and the resulting audit_syslog.so can be loaded into the server and ready to use. Log into the server and type: mysql> INSTALL PLUGIN audit_syslog SONAME 'audit_syslog.so'; This will install the plugin and will start updating the syslog immediately. Note that the audit plugin attaches to the immediate thread and cannot be uninstalled while that thread is active. This means that you cannot run the UNISTALL command until you log into a different connection (thread) on the server. Once the plugin is loaded, the system log will show output such as the following: Oct  8 15:33:21 machine mysql_audit:[8337]: 87: User: root[root] @ localhost []  Command: (null)  Query: INSTALL PLUGIN audit_syslog SONAME 'audit_syslog.so' Oct  8 15:33:21 machine mysql_audit:[8337]: 87: User: root[root] @ localhost []  Command: Query  Query: INSTALL PLUGIN audit_syslog SONAME 'audit_syslog.so' Oct  8 15:33:40 machine mysql_audit:[8337]: 87: User: root[root] @ localhost []  Command: (null)  Query: show tables Oct  8 15:33:40 machine mysql_audit:[8337]: 87: User: root[root] @ localhost []  Command: Query  Query: show tables Oct  8 15:33:43 machine mysql_audit:[8337]: 87: User: root[root] @ localhost []  Command: (null)  Query: select * from t1 Oct  8 15:33:43 machine mysql_audit:[8337]: 87: User: root[root] @ localhost []  Command: Query  Query: select * from t1 It appears that two of each event is being shown, but in actuality, these are two separate event types - the result event and the status event. This could be refined further by changing the audit_syslog_notify function to handle the different event sub-types in a different manner.  So far, it seems that the logging is working with events showing up in the syslog output. The issue now is that the counters created earlier to track the number of events by type are not accessible when the plugin is being run. Instead there needs to be a way to expose the plugin specific information to the service and vice versa. This could be done via the information_schema plugin api, but for something as simple as counters, the obvious choice is the system status variables. This is done using the standard structure and the declaration: /*  Plugin status variables for SHOW STATUS */ static struct st_mysql_show_var audit_syslog_status[]= {   { "Audit_syslog_total_calls",     (char *) &total_number_of_calls,     SHOW_INT },   { "Audit_syslog_general_events",     (char *) &number_of_calls_general,     SHOW_INT },   { "Audit_syslog_connection_events",     (char *) &number_of_calls_connection,     SHOW_INT },   { 0, 0, SHOW_INT } };   The structure is simply the name that will be displaying in the mysql service, the address of the associated variables, and the data type being used for the counter. It is finished with a blank structure to show that there are no more variables. Remember that status variables may have the same name for variables from other plugin, so it is considered appropriate to add the plugin name at the start of the status variable name to avoid confusion. Looking at the status variables in the mysql client shows something like the following: mysql> show global status like "audit%"; +--------------------------------+-------+ | Variable_name                  | Value | +--------------------------------+-------+ | Audit_syslog_connection_events | 1     | | Audit_syslog_general_events    | 2     | | Audit_syslog_total_calls       | 3     | +--------------------------------+-------+ 3 rows in set (0.00 sec) The final connectivity piece for the plugin is to allow the interactive change of the logging level between the plugin and the system. This requires the ability to send changes via the mysql service through to the plugin. This is done using the system variables interface and defining a single variable to keep track of the active logging level for the facility. /* Plugin system variables for SHOW VARIABLES */ static MYSQL_SYSVAR_STR(loglevel, audit_loglevel,                         PLUGIN_VAR_RQCMDARG,                         "User can specify the log level for auditing",                         audit_loglevel_check, audit_loglevel_update, "LOG_NOTICE"); static struct st_mysql_sys_var* audit_syslog_sysvars[] = {     MYSQL_SYSVAR(loglevel),     NULL }; So now the system variable 'loglevel' is defined for the plugin and associated to the global variable 'audit_loglevel'. The check or validation function is defined to make sure that no garbage values are attempted in the update of the variable. The update function is used to save the new value to the variable. Note that the audit_syslog_sysvars structure is defined in the general plugin descriptor to associate the link between the plugin and the system and how much they interact. Next comes the implementation of the validation function and the update function for the system variable. It is worth noting that if you have a simple numeric such as integers for the variable types, the validate function is often not required as MySQL will handle the automatic check and validation of simple types. /* longest valid value */ #define MAX_LOGLEVEL_SIZE 100 /* hold the valid values */ static const char *possible_modes[]= { "LOG_ERROR", "LOG_WARNING", "LOG_NOTICE", NULL };  static int audit_loglevel_check(     THD*                        thd,    /*!< in: thread handle */     struct st_mysql_sys_var*    var,    /*!< in: pointer to system                                         variable */     void*                       save,   /*!< out: immediate result                                         for update function */     struct st_mysql_value*      value)  /*!< in: incoming string */ {     char buff[MAX_LOGLEVEL_SIZE];     const char *str;     const char **found;     int length;     length= sizeof(buff);     if (!(str= value->val_str(value, buff, &length)))         return 1;     /*         We need to return a pointer to a locally allocated value in "save".         Here we pick to search for the supplied value in an global array of         constant strings and return a pointer to one of them.         The other possiblity is to use the thd_alloc() function to allocate         a thread local buffer instead of the global constants.     */     for (found= possible_modes; *found; found++)     {         if (!strcmp(*found, str))         {             *(const char**)save= *found;             return 0;         }     }     return 1; } The validation function is simply to take the value being passed in via the SET GLOBAL VARIABLE command and check if it is one of the pre-defined values allowed  in our possible_values array. If it is found to be valid, then the value is assigned to the save variable ready for passing through to the update function. static void audit_loglevel_update(     THD*                        thd,        /*!< in: thread handle */     struct st_mysql_sys_var*    var,        /*!< in: system variable                                             being altered */     void*                       var_ptr,    /*!< out: pointer to                                             dynamic variable */     const void*                 save)       /*!< in: pointer to                                             temporary storage */ {     /* assign the new value so that the server can read it */     *(char **) var_ptr= *(char **) save;     /* assign the new value to the internal variable */     audit_loglevel= *(char **) save; } Since all the validation has been done already, the update function is quite simple for this plugin. The first part is to update the system variable pointer so that the server can read the value. The second part is to update our own global plugin variable for tracking the value. Notice that the save variable is passed in as a void type to allow handling of various data types, so it must be cast to the appropriate data type when assigning it to the variables. Looking at how the latest changes affect the usage of the plugin and the interaction within the server shows: mysql> show global variables like "audit%"; +-----------------------+------------+ | Variable_name         | Value      | +-----------------------+------------+ | audit_syslog_loglevel | LOG_NOTICE | +-----------------------+------------+ 1 row in set (0.00 sec) mysql> set global audit_syslog_loglevel="LOG_ERROR"; Query OK, 0 rows affected (0.00 sec) mysql> show global status like "audit%"; +--------------------------------+-------+ | Variable_name                  | Value | +--------------------------------+-------+ | Audit_syslog_connection_events | 1     | | Audit_syslog_general_events    | 11    | | Audit_syslog_total_calls       | 12    | +--------------------------------+-------+ 3 rows in set (0.00 sec) mysql> show global variables like "audit%"; +-----------------------+-----------+ | Variable_name         | Value     | +-----------------------+-----------+ | audit_syslog_loglevel | LOG_ERROR | +-----------------------+-----------+ 1 row in set (0.00 sec)   So now we have a plugin that will audit the events on the system and log the details to the system log. It allows for interaction to see the number of different events within the server details and provides a mechanism to change the logging level interactively via the standard system methods of the SET command. A more complex auditing plugin may have more detailed code, but each of the above areas is what will be involved and simply expanded on to add more functionality. With the above skeleton code, it is now possible to create your own audit plugins to implement your own auditing requirements. If, however, you are not of the coding persuasion, then you could always consider the option of the MySQL Enterprise Audit plugin that is available to purchase.

    Read the article

  • SharePoint.DesignFactory.ContentFiles–building WCM sites

    - by svdoever
    One of the use cases where we use the SharePoint.DesignFactory.ContentFiles tooling is in building SharePoint Publishing (WCM) solutions for SharePoint 2007, SharePoint 2010 and Office365. Publishing solutions are often solutions that have one instance, the publishing site (possibly with subsites), that in most cases need to go through DTAP. If you dissect a publishing site, in most case you have the following findings: The publishing site spans a site collection The branding of the site is specified in the root site, because: Master pages live in the root site (/_catalogs/masterpage) Page layouts live in the root site (/_catalogs/masterpage) The style library lives in the root site ( /Style Library) and contains images, css, javascript, xslt transformations for your CQWP’s, … Preconfigured web parts live in the root site (/_catalogs/wp) The root site and subsites contains a document library called Pages (or your language-specific version of it) containing publishing pages using the page layouts and master pages The site collection contains content types, fields and lists When using the SharePoint.DesignFactory.ContentFiles tooling it is very easy to create, test, package and deploy the artifacts that can be uploaded to the SharePoint content database. This can be done in a fast and simple way without the need to create and deploy WSP packages. If we look at the above list of artifacts we can use SharePoint.DesignFactory.ContentFiles for master pages, page layouts, the style library, web part configurations, and initial publishing pages (these are normally made through the SharePoint web UI). Some artifacts like content types, fields and lists in the above list can NOT be handled by SharePoint.DesignFactory.ContentFiles, because they can’t be uploaded to the SharePoint content database. The good thing is that these artifacts are the artifacts that don’t change that much in the development of a SharePoint Publishing solution. There are however multiple ways to create these artifacts: Use paper script: create them manually in each of the environments based on documentation Automate the creation of the artifacts using (PowerShell) script Develop a WSP package to create these artifacts I’m not a big fan of the third option (see my blog post Thoughts on building deployable and updatable SharePoint solutions). It is a lot of work to create content types, fields and list definitions using all kind of XML files, and it is not allowed to modify these artifacts when in use. I know… SharePoint 2010 has some content type upgrade possibilities, but I think it is just too cumbersome. The first option has the problem that content types and fields get ID’s, and that these ID’s must be used by the metadata on for example page layouts. No problem for SharePoint.DesignFactory.ContentFiles, because it supports deploy-time resolving of these ID’s using PowerShell. For example consider the following metadata definition for the page layout contactpage-wcm.aspx.properties.ps1: Metadata page layout # This script must return a hashtable @{ name=value; ... } of field name-value pairs # for the content file that this script applies to. # On deployment to SharePoint, these values are written as fields in the corresponding list item (if any) # Note that fields must exist; they can be updated but not created or deleted. # This script is called right after the file is deployed to SharePoint.   # You can use the script parameters and arbitrary PowerShell code to interact with SharePoint. # e.g. to calculate properties and values at deployment time.   param([string]$SourcePath, [string]$RelativeUrl, $Context) @{     "ContentTypeId" = $Context.GetContentTypeID('GeneralPage');     "MasterPageDescription" = "Cloud Aviator Contact pagelayout (wcm - don't use)";     "PublishingHidden" = "1";     "PublishingAssociatedContentType" = $Context.GetAssociatedContentTypeInfo('GeneralPage') } The PowerShell functions GetContentTypeID and GetAssociatedContentTypeInfo can at deploy-time resolve the required information from the server we are deploying to. I personally prefer the second option: automate creation through PowerShell, because there are PowerShell scripts available to export content types and fields. An example project structure for a typical SharePoint WCM site looks like: Note that this project uses DualLayout. So if you build Publishing sites using SharePoint, checkout out the completely free SharePoint.DesignFactory.ContentFiles tooling and start flying!

    Read the article

  • SQL SERVER – SOS_SCHEDULER_YIELD – Wait Type – Day 8 of 28

    - by pinaldave
    This is a very interesting wait type and quite often seen as one of the top wait types. Let us discuss this today. From Book On-Line: Occurs when a task voluntarily yields the scheduler for other tasks to execute. During this wait the task is waiting for its quantum to be renewed. SOS_SCHEDULER_YIELD Explanation: SQL Server has multiple threads, and the basic working methodology for SQL Server is that SQL Server does not let any “runnable” thread to starve. Now let us assume SQL Server OS is very busy running threads on all the scheduler. There are always new threads coming up which are ready to run (in other words, runnable). Thread management of the SQL Server is decided by SQL Server and not the operating system. SQL Server runs on non-preemptive mode most of the time, meaning the threads are co-operative and can let other threads to run from time to time by yielding itself. When any thread yields itself for another thread, it creates this wait. If there are more threads, it clearly indicates that the CPU is under pressure. You can fun the following DMV to see how many runnable task counts there are in your system. SELECT scheduler_id, current_tasks_count, runnable_tasks_count, work_queue_count, pending_disk_io_count FROM sys.dm_os_schedulers WHERE scheduler_id < 255 GO If you notice a two-digit number in runnable_tasks_count continuously for long time (not once in a while), you will know that there is CPU pressure. The two-digit number is usually considered as a bad thing; you can read the description of the above DMV over here. Additionally, there are several other counters (%Processor Time and other processor related counters), through which you can refer to so you can validate CPU pressure along with the method explained above. Reducing SOS_SCHEDULER_YIELD wait: This is the trickiest part of this procedure. As discussed, this particular wait type relates to CPU pressure. Increasing more CPU is the solution in simple terms; however, it is not easy to implement this solution. There are other things that you can consider when this wait type is very high. Here is the query where you can find the most expensive query related to CPU from the cache Note: The query that used lots of resources but is not cached will not be caught here. SELECT SUBSTRING(qt.TEXT, (qs.statement_start_offset/2)+1, ((CASE qs.statement_end_offset WHEN -1 THEN DATALENGTH(qt.TEXT) ELSE qs.statement_end_offset END - qs.statement_start_offset)/2)+1), qs.execution_count, qs.total_logical_reads, qs.last_logical_reads, qs.total_logical_writes, qs.last_logical_writes, qs.total_worker_time, qs.last_worker_time, qs.total_elapsed_time/1000000 total_elapsed_time_in_S, qs.last_elapsed_time/1000000 last_elapsed_time_in_S, qs.last_execution_time, qp.query_plan FROM sys.dm_exec_query_stats qs CROSS APPLY sys.dm_exec_sql_text(qs.sql_handle) qt CROSS APPLY sys.dm_exec_query_plan(qs.plan_handle) qp ORDER BY qs.total_worker_time DESC -- CPU time You can find the most expensive queries that are utilizing lots of CPU (from the cache) and you can tune them accordingly. Moreover, you can find the longest running query and attempt to tune them if there is any processor offending code. Additionally, pay attention to total_worker_time because if that is also consistently higher, then  the CPU under too much pressure. You can also check perfmon counters of compilations as they tend to use good amount of CPU. Index rebuild is also a CPU intensive process but we should consider that main cause for this query because that is indeed needed on high transactions OLTP system utilized to reduce fragmentations. Note: The information presented here is from my experience and there is no way that I claim it to be accurate. I suggest reading Book OnLine for further clarification. All of the discussions of Wait Stats in this blog is generic and varies from system to system. It is recommended that you test this on a development server before implementing it to a production server. Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, PostADay, SQL, SQL Authority, SQL Query, SQL Scripts, SQL Server, SQL Tips and Tricks, SQL Wait Stats, SQL Wait Types, T SQL, Technology

    Read the article

  • Don’t miss this very popular presentation on Punchout in iProcurement on June 26th 2012

    - by user793553
    Don’t miss this very popular presentation on Punchout in iProcurement on June 26th.  See Doc ID 1448447.1 for the Webcast details. ADVISOR WEBCAST: Punchout in iProcurement PRODUCT FAMILY: EBZs- Procurement   June 26, 2012 at 14:00 UK / 15:00 Cairo / 6:00 am Pacific / 7:00 am Mountain / 9:00 am Eastern This one-hour session is recommended for technical and functional users who are maintaining and/or implementing the Punchout from iProcurement. The session will provide an overview of the different Punchout model, setup, and the Punchout to PO xml/cxml cycle. Also, it will provide tips in troubleshooting the common issues when new supplier is added to Punchout or the existing one stops working. TOPICS WILL INCLUDE: Overview of the Punchout Models. Provide the knowledge in the Punchout to PO Process cycle. Demo - Punchout. Certificates and setup. Learn the common issues and how to address in an efficient way. (Documentation and Notes) A short, live demonstration (only if applicable) and question and answer period will be included. Oracle Advisor Webcasts are dedicated to building your awareness around our products and services. This session does not replace offerings from Oracle Global Support Services. Current Schedule can be found on Note 740966.1 Post Presentation Recordings can be found on Note 740964.1 WebEx Conference Details Topic: Advisor Webcast - Punchout in iProcuremen Date and Time: Tuesday, June 26, 2012 3:00 pm, Egypt Time (Cairo, GMT+02:00) Tuesday, June 26, 2012 2:00 pm, GMT Summer Time (London, GMT+01:00) Tuesday, June 26, 2012 9:00 am, Eastern Daylight Time (New York, GMT-04:00) Tuesday, June 26, 2012 7:00 am, Mountain Daylight Time (Denver, GMT-06:00) Event number: 597 373 155 -------------------------------------------------------  To register for this meeting  -------------------------------------------------------  1. Event address for attendees: https://oracleaw.webex.com/oracleaw/onstage/g.php?d=597373155&t=a 2. Register for the meeting.  Once the host approves your request, you will receive a confirmation email with instructions for joining the meeting. InterCall Audio Instructions A list of Toll-Free Numbers can be found below. VOICESTREAMING IS AVAILABLE teleconference ID: 70528713 UK standard International:+44 1452 562 665 US Free Call: 1866 230 1938 US Local call: 1845 608 8023 Global Toll-Free Numbers MOS doc#:  https://metalink3.oracle.com/od/faces/secure/km/DocumentDisplay.jspx?id=1148600.1 Designation Number Argentina Free Call 0800 444 1009 Australia Free Call 1800 763 650 Austria Free Call 0800 111 956 Austria Local Call 0192 865 72 Belgium Free Call 0800 724 46 Belgium Local Call 0817 000 60 Brazil Free Call 0800 761 0835 Bulgaria Free Call 0080 011 511 76 Canada Free Call 1866 984 6577 Columbia Free Call 0180 091 562 17 Croatia Free Call 0800 222 305 Cyprus Free Call 8009 6341 Czech Republic Free Call 8007 007 95 Denmark Free Call 8088 8467 Denmark Local Call 3272 7506 Finland Free Call 0800 112 398 Finland Local Call 0923 114 014 France Free Call 0805 110 463 France Local Call 0359 580 290 Germany Free Call 0800 101 4918 Germany Local Call 0692 222 161 19 Greece Free Call 0080 012 8135 Hong Kong Free Call 8009 661 55 Hungary Free Call 0680 018 839 Hungary Local Call 0180 889 97 India Free Call 0008 001 006 600 Ireland Free Call 1800 300 170 Ireland Local Call 0143 198 35 Israel Free Call 1809 431 440 Italy Free Call 8007 840 87 Italy Local Call 0236 009 700 Japan Free Call 0066 338 124 31 Latvia Free Call 8000 3680 Luxembourg Free Call 8002 7941 Malaysia Free Call 1800 814 528 Mexico Free Call 0018 666 864 905 Monaco Free Call 8009 3655 Netherlands Free Call 0800 949 4596 Netherlands Local Call 0207 168 000 New Zealand Free Call 0800 451 190 North China Free Call 1080 074 413 29 Norway Free Call 8001 8057 Norway Local Call 2151 0847 Poland Free Call 0080 012 135 73 Portugal Free Call 8007 894 20 Romania Free Call 0800 895 558 Russia Free Call 8108 002 385 2044 Slovenia Free Call 0800 804 55 South Africa Free Call 0800 982 794 South China Free Call 1080 044 111 82 South Korea Free Call 0079 814 800 7887 Spain Free Call 9009 389 85 Spain Local Call 9111 421 10 Sweden Free Call 0200 214 344 Sweden Local Call 0850 596 375 Switzerland Free Call 0800 835 040 Switzerland Local Call 0445 804 280 Thailand Free Call 0018 004 421 98 UK Free Call 0800 073 1830 UK Local Call 0844 871 9364 UK National Call 0871 700 0309 UK Standard International +44 (0) 1452 562 665 USA Free Call 1866 230 1938   Back to the top   Copyright? 2010, Oracle. All rights reserved. Contact Us | Legal Notices and Terms of Use | Privacy Statement

    Read the article

  • [MISC GEEKERY] Support for Some Versions of Windows is Ending

    - by Matthew Guay
    Are you sticking with your older version of Windows instead of upgrading to Windows 7?  There’s no problem with that, but here’s a quick reminder to make sure you’re running the latest service pack to stay protected. Microsoft offers security updates and more throughout the lifetime of a version of Windows, and periodically they roll all the latest updates and improvements together into a service pack.  After a while, only computers running the latest service pack will still get updates to keep them safe. Recently, Microsoft has been warning that support is ending for Windows XP with Service Pack 2 and the release version of Windows Vista.  When support ends, you will not receive any new security updates for Windows.  You can continue to use your computer the same as before, but it may not be as secure and if new security issues are discovered they will not be updated. However, it’s easy to stay supported: simply install XP Service Pack 3 or Vista Service Pack 2, depending on your computer.  Here’s how to do that: Windows XP To install Windows XP Service Pack 3, you can either check Windows Update for updates, or simply download it from Microsoft at this link: Download XP Service Pack 3 Run the download (or if you’re updating from Windows Update the installer will automatically launch), and proceed just as you normally would when installing a program.  Your computer will have to reboot during the install, so make sure you’ve saved all your work and closed other programs before installing.   To check what service pack your computer is running, click Start, then right-click on the My Computer button and choose Properties. This will show you what version and service pack of Windows you are running, and in this screenshot we see this computer has be updated to Service Pack 3. Please Note:  The version of XP shipped with Windows XP Mode in Windows 7 comes preconfigured with Service Pack 3, and does not need updated.  Additionally, if your computer is running the 64 bit version of Windows XP, then Service Pack 2 is the latest service pack for your computer, and it is still supported. Windows Vista If your computer is running Windows Vista, you can install Service Pack 2 to stay up to date and supported.  Simply check Windows Update for Service Pack 2 if you haven’t installed it yet, or download the installer for your computer from the link below: 32 bit: Vista Service Pack 2 32-bit 64 bit: Vista Service Pack 2 64-bit Run the installer, and simply set it up as a normal program installation.  Do note that your computer will reboot during the installation, so make sure to save your work and close other programs before installing. To see what service pack your computer is running, click the Start orb, then right-click on the Computer button and select Properties. This will show what service pack and edition of Windows Vista your computer is running right at the top of the page. Conclusion Microsoft makes it easy to keep using your computer safely and securely even if you choose to keep using your older version of Windows.  By installing the latest service pack, you will make sure that your computer will be supported for years to come.  Windows 7 users, you don’t need to worry; no service has been released for it yet.  Stay tuned, and we’ll let you know when any new service packs are available. www.microsoft.com/EOS – End of Support Information from Microsoft Similar Articles Productive Geek Tips Remove Optional and Probably Unnecessary Windows Vista ComponentsRequesting Hotfixes from Microsoft the Easy WayUnderstanding Windows Vista Aero Glass RequirementsAdd Network Support to Windows Live MovieMakerCustomize the Manufacturer Support Info in Windows 7 or Vista TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 PCmover Professional OutSync will Sync Photos of your Friends on Facebook and Outlook Windows 7 Easter Theme YoWindoW, a real time weather screensaver Optimize your computer the Microsoft way Stormpulse provides slick, real time weather data Geek Parents – Did you try Parental Controls in Windows 7?

    Read the article

  • Add a Hovering Image Toolbar to Firefox

    - by Asian Angel
    When you work with webpage images in Firefox you normally have to use the Context Menu to do anything with them. The Image Toolbar extension provides an extra toolbar to use when you hover your mouse over webpage images. Note: This extension will not function if you have the NoScript extension installed/enabled unless JavaScript has permission to be active on that page. Before You can see the available “Context Menu” options for working with images here. Not bad but it would be nice if some other convenient options were available as well. Image Toolbar in Action Once you have installed the extension you will be able to view the toolbar whenever you hover your mouse over an image. All of the commands are active by default but you can choose what is available in the options. The toolbar will also appear in the upper left region of the image but can be set to appear relative to the cursor. Note: The default minimum image size for the toolbar to appear over is “260 x 260 pixels” so you will probably want to change it to a much smaller size (see options below). Here is what is available in the Image Toolbar: Save – Choose between being prompted when saving or automatically saving to a specified location Copy – Copies image and image URL so that you can paste the image or URL depending on the app pasted into Print – Provides print preview and printing capabilities Info – Opens a window with “properties information” about the image Folder – Opens browser’s download folder in Windows Explorer The “Save, Copy, Print, & Folder Commands” are all pretty clear in what you can expect from them but what about the “Info Command”? This is what you will see if you use the “Info Command” and expand the window out all the way. Very nice… Options There are quite a few options available for what appears to be such a small toolbar. The first “Tab Area” lets you set up the “Save Scheme” that best suits your personal needs. You can choose which commands are available in the toolbar, decide if you would like text labels visible, and enable small icons if desired. As mentioned above the default image size for the toolbar to appear is “260 x 260 pixels”…we set ours for “10 x 10 pixels”. If you would like the toolbar to appear relative to your mouse cursor as opposed to the upper left corner of the image then you can select for that here. Conclusion If you have been wanting more options for working with webpage images in Firefox then this will make a very useful and convenient addition to your browser. Links Download the Image Toolbar extension (Mozilla Add-ons) Similar Articles Productive Geek Tips Conserve Space in Firefox by Combining ToolbarsShow Alexa Ranking in FirefoxLightweight Extension to Show PageRank in FirefoxSwitch Windows by Hovering the Mouse Over a Window in Windows 7 or VistaQuick Tip: Show PageRank in Firefox while Google Toolbar is Hidden TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Roadkill’s Scan Port scans for open ports Out of 100 Tweeters Out of band Security Update for Internet Explorer 7 Cool Looking Screensavers for Windows SyncToy syncs Files and Folders across Computers on a Network (or partitions on the same drive) If it were only this easy

    Read the article

  • Displaying JSON in your Browser

    - by Rick Strahl
    Do you work with AJAX requests a lot and need to quickly check URLs for JSON results? Then you probably know that it’s a fairly big hassle to examine JSON results directly in the browser. Yes, you can use FireBug or Fiddler which work pretty well for actual AJAX requests, but if you just fire off a URL for quick testing in the browser you usually get hit by the Save As dialog and the download manager, followed by having to open the saved document in a text editor in FireFox. Enter JSONView which allows you to simply display JSON results directly in the browser. For example, imagine I have a URL like this: http://localhost/westwindwebtoolkitweb/RestService.ashx?Method=ReturnObject&format=json&Name1=Rick&Name2=John&date=12/30/2010 typed directly into the browser and that that returns a complex JSON object. With JSONView the result looks like this: No fuss, no muss. It just works. Here the result is an array of Person objects that contain additional address child objects displayed right in the browser. JSONView basically adds content type checking for application/json results and when it finds a JSON result takes over the rendering and formats the display in the browser. Note that it re-formats the raw JSON as well for a nicer display view along with collapsible regions for objects. You can still use View Source to see the raw JSON string returned. For me this is a huge time-saver. As I work with AJAX result data using GET and REST style URLs quite a bit it’s a big timesaver. To quickly and easily display JSON is a key feature in my development day and JSONView for all its simplicity fits that bill for me. If you’re doing AJAX development and you often review URL based JSON results do yourself a favor and pick up a copy of JSONView. Other Browsers JSONView works only with FireFox – what about other browsers? Chrome Chrome actually displays raw JSON responses as plain text without any plug-ins. There’s no plug-in or configuration needed, it just works, although you won’t get any fancy formatting. [updated from comments] There’s also a port of JSONView available for Chrome from here: https://chrome.google.com/webstore/detail/chklaanhfefbnpoihckbnefhakgolnmc It looks like it works just about the same as the JSONView plug-in for FireFox. Thanks for all that pointed this out… Internet Explorer Internet Explorer probably has the worst response to JSON encoded content: It displays an error page as it apparently tries to render JSON as XML: Yeah that seems real smart – rendering JSON as an XML document. WTF? To get at the actual JSON output, you can use View Source. To get IE to display JSON directly as text you can add a Mime type mapping in the registry:   Create a new application/json key in: HKEY_CLASSES_ROOT\MIME\Database\ContentType\application/json Add a string value of CLSID with a value of {25336920-03F9-11cf-8FD0-00AA00686F13} Add a DWORD value of Encoding with a value of 80000 I can’t take credit for this tip – found it here first on Sky Sander’s Blog. Note that the CLSID can be used for just about any type of text data you want to display as plain text in the IE. It’s the in-place display mechanism and it should work for most text content. For example it might also be useful for looking at CSS and JS files inside of the browser instead of downloading those documents as well. © Rick Strahl, West Wind Technologies, 2005-2011Posted in ASP.NET  AJAX  

    Read the article

  • Crop, Edit, and Print Photos in Windows 7 Media Center

    - by DigitalGeekery
    Windows Media Center is a nice application for managing and displaying your personal photos, but you may occasionally need to make some basic edits to your pictures. Today we’ll take a look at how to crop, edit, and print photos right from Windows 7 Media Center. From within the Picture Library in Windows Media Center, choose a photo to work with, right-click and select Picture Details. You can also access this option with a Media Center remote by clicking the “i” button. Note: You’ll notice you have the option to rotate the picture from this menu. It is also available on the next screen.  Rotate a picture Now you’ll see more options on the Picture Details screen. From here you can rotate, Print, or Touch Up, Delete, or Burn a CD/DVD. To rotate the picture, simple select Rotate. Note: If you want your photo saved with the new orientation, you’ll need to select Save from the Touch Up screen that we will look at later in the article.   Each click will rotate the picture 90 degrees clockwise. You’ll see the new orientation of the picture displayed on the Picture Details screen after you have clicked Rotate. Print a picture From the Picture Details screen, select Print. Click Print again. Media Center automatically prints to your default printer, so make sure your desired target printer is set as default. Crop and Edit Photos To edit or crop your photo, select Touch Up. Touch Up options includes, Crop, Contrast, and Red Eye removal. First, we’ll select the Crop button to crop our photo.   You will see a cropping area overlay appear on your photo. Select one of the buttons below to adjust the location, size, and orientation of the area to be cropped. When you’re happy with your selection, click Save. You’ll be prompted to confirm your save. Click Yes to permanently save your edits. You can also apply Contrast or Red Eye adjustments to your photos. There aren’t any advanced settings for these options. You merely toggle the Contrast or Red Eye on or off by selecting the option. Be sure to click Save before exiting to if you’ve made any changes you wish to permanently apply to the photos. This includes rotating the images. While this method is not likely to be replace your favorite image editing software, it does give you the ability to make basic edits and print photos directly from Windows Media Center. With a Media Center remote, you can even do all your edits from the comfort of your recliner. Similar Articles Productive Geek Tips Using Netflix Watchnow in Windows Vista Media Center (Gmedia)Schedule Updates for Windows Media CenterIntegrate Hulu Desktop and Windows Media Center in Windows 7Add Color Coding to Windows 7 Media Center Program GuideIntegrate Boxee with Media Center in Windows 7 TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Outlook Connector Upgrade Error Gadfly is a cool Twitter/Silverlight app Enable DreamScene in Windows 7 Microsoft’s “How Do I ?” Videos Home Networks – How do they look like & the problems they cause Check Your IMAP Mail Offline In Thunderbird

    Read the article

  • Understanding EDI 997

    - by VishnuTiwariBlog
    Hi Guys, This is for the EDI starter. Below is the complete detail of EDI 997 segment and element details. 997 Functional Acknowledgment Transaction Layout:   No. Seg ID Name Description Example M/O 010 ST Transaction Set Header To indicate the start of a transaction set and to assign a control number ST*997*382823~   M ST01   Code uniquely identifying a Transaction Set   M ST02   Identifying control number that must be unique within the transaction set functional group assigned by the originator for a transaction set   M 020 AK1 Functional Group Response Header To start acknowledgment of a functional group AK1*QM*2459823 M        AK101   Code identifying a group of application related transaction sets IN Invoice Information (810) SH Ship Notice/Manifest (856)     AK102   Assigned number originated and maintained by the sender     030 AK2 Transaction Set Response Header To start acknowledgment of a single transaction set AK2*856*001 M AK201   Code uniquely identifying a Transaction Set 810 Invoice 856 Ship Notice/Manifest   M AK202   Identifying control number that must be unique within the transaction set functional group assigned by the originator for a transaction set   M 040 AK3 Data Segment Note To report errors in a data segment and identify the location of the data segment AK3*TD3*9 O AK301 Segment ID Code Code defining the segment ID of the data segment in error (See Appendix A - Number 77)     AK302 Segment Position in Transaction Set The numerical count position of this data segment from the start of the transaction set: the transaction set header is count position 1     050 AK4 Data Element Note To report errors in a data element or composite data structure and identify the location of the data element AK4*2**2 O AK401 Position in Segment Code indicating the relative position of a simple data element, or the relative position of a composite data structure combined with the relative position of the component data element within the composite data structure, in error; the count starts with 1 for the simple data element or composite data structure immediately following the segment ID     AK402 Element Position in Segment This is used to indicate the relative position of a simple data element, or the relative position of a composite data structure with the relative position of the component within the composite data structure, in error; in the data segment the count starts with 1 for the simple data element or composite data structure immediately following the segment ID     AK403 Data Element Syntax Error Code Code indicating the error found after syntax edits of a data element 1 Mandatory Data Element Missing 2 Conditional Required Data Element Missing 3 Too Many Data Elements 4 Data Element Too Short 5 Data Element Too Long 6 Invalid Character in Data Element 7 Invalid Code Value 8 Invalid Date 9 Invalid Time 10 Exclusion Condition Violated     AK404 Copy of Bad Data Element This is a copy of the data element in error     060 AK5 AK5 Transaction Set Response Trailer To acknowledge acceptance or rejection and report errors in a transaction set AK5*A~ AK5*R*5~ M AK501 Transaction Set Acknowledgment Code Code indicating accept or reject condition based on the syntax editing of the transaction set A Accepted E Accepted But Errors Were Noted R Rejected     AK502 Transaction Set Syntax Error Code Code indicating error found based on the syntax editing of a transaction set 1 Transaction Set Not Supported 2 Transaction Set Trailer Missing 3 Transaction Set Control Number in Header and Trailer Do Not Match 4 Number of Included Segments Does Not Match Actual Count 5 One or More Segments in Error 6 Missing or Invalid Transaction Set Identifier 7 Missing or Invalid Transaction Set Control Number     070 AK9 Functional Group Response Trailer To acknowledge acceptance or rejection of a functional group and report the number of included transaction sets from the original trailer, the accepted sets, and the received sets in this functional group AK9*A*1*1*1~ AK9*R*1*1*0~ M AK901 Functional Group Acknowledge Code Code indicating accept or reject condition based on the syntax editing of the functional group A Accepted E Accepted, But Errors Were Noted. R Rejected     AK902 Number of Transaction Sets Included Total number of transaction sets included in the functional group or interchange (transmission) group terminated by the trailer containing this data element     AK903 Number of Received Transaction Sets Number of Transaction Sets received     AK904 Number of Accepted Transaction Sets Number of accepted Transaction Sets in a Functional Group     AK905 Functional Group Syntax Error Code Code indicating error found based on the syntax editing of the functional group header and/or trailer 1 Functional Group Not Supported 2 Functional Group Version Not Supported 3 Functional Group Trailer Missing 4 Group Control Number in the Functional Group Header and Trailer Do Not Agree 5 Number of Included Transaction Sets Does Not Match Actual Count 6 Group Control Number Violates Syntax     080 SE Transaction Set Trailer To indicate the end of the transaction set and provide the count of the transmitted segments (including the beginning (ST) and ending (SE) segments) SE*9*223~ M SE01 Number of Included Segments Total number of segments included in a transaction set including ST and SE segments     SE02 Transaction Set Control Number Identifying control number that must be unique within the transaction set functional group assigned by the originator for a transaction set

    Read the article

  • Understanding EDI 997.

    - by VishnuTiwariBlog
    Hi Guys, This is for the EDI starter. Below is the complete detail of EDI 997 segment and element details. 997 Functional Acknowledgment Transaction Layout: No. Seg ID Name Description Example M/O 010 ST Transaction Set Header To indicate the start of a transaction set and to assign a control number ST*997*382823~   M ST01   Code uniquely identifying a Transaction Set   M ST02   Identifying control number that must be unique within the transaction set functional group assigned by the originator for a transaction set   M 020 AK1 Functional Group Response Header To start acknowledgment of a functional group AK1*QM*2459823 M        AK101   Code identifying a group of application related transaction sets IN Invoice Information (810) SH Ship Notice/Manifest (856)     AK102   Assigned number originated and maintained by the sender     030 AK2 Transaction Set Response Header To start acknowledgment of a single transaction set AK2*856*001 M AK201   Code uniquely identifying a Transaction Set 810 Invoice 856 Ship Notice/Manifest   M AK202   Identifying control number that must be unique within the transaction set functional group assigned by the originator for a transaction set   M 040 AK3 Data Segment Note To report errors in a data segment and identify the location of the data segment AK3*TD3*9 O AK301 Segment ID Code Code defining the segment ID of the data segment in error (See Appendix A - Number 77)     AK302 Segment Position in Transaction Set The numerical count position of this data segment from the start of the transaction set: the transaction set header is count position 1     050 AK4 Data Element Note To report errors in a data element or composite data structure and identify the location of the data element AK4*2**2 O AK401 Position in Segment Code indicating the relative position of a simple data element, or the relative position of a composite data structure combined with the relative position of the component data element within the composite data structure, in error; the count starts with 1 for the simple data element or composite data structure immediately following the segment ID     AK402 Element Position in Segment This is used to indicate the relative position of a simple data element, or the relative position of a composite data structure with the relative position of the component within the composite data structure, in error; in the data segment the count starts with 1 for the simple data element or composite data structure immediately following the segment ID     AK403 Data Element Syntax Error Code Code indicating the error found after syntax edits of a data element 1 Mandatory Data Element Missing 2 Conditional Required Data Element Missing 3 Too Many Data Elements 4 Data Element Too Short 5 Data Element Too Long 6 Invalid Character in Data Element 7 Invalid Code Value 8 Invalid Date 9 Invalid Time 10 Exclusion Condition Violated     AK404 Copy of Bad Data Element This is a copy of the data element in error     060 AK5 AK5 Transaction Set Response Trailer To acknowledge acceptance or rejection and report errors in a transaction set AK5*A~ AK5*R*5~ M AK501 Transaction Set Acknowledgment Code Code indicating accept or reject condition based on the syntax editing of the transaction set A Accepted E Accepted But Errors Were Noted R Rejected     AK502 Transaction Set Syntax Error Code Code indicating error found based on the syntax editing of a transaction set 1 Transaction Set Not Supported 2 Transaction Set Trailer Missing 3 Transaction Set Control Number in Header and Trailer Do Not Match 4 Number of Included Segments Does Not Match Actual Count 5 One or More Segments in Error 6 Missing or Invalid Transaction Set Identifier 7 Missing or Invalid Transaction Set Control Number     070 AK9 Functional Group Response Trailer To acknowledge acceptance or rejection of a functional group and report the number of included transaction sets from the original trailer, the accepted sets, and the received sets in this functional group AK9*A*1*1*1~ AK9*R*1*1*0~ M AK901 Functional Group Acknowledge Code Code indicating accept or reject condition based on the syntax editing of the functional group A Accepted E Accepted, But Errors Were Noted. R Rejected     AK902 Number of Transaction Sets Included Total number of transaction sets included in the functional group or interchange (transmission) group terminated by the trailer containing this data element     AK903 Number of Received Transaction Sets Number of Transaction Sets received     AK904 Number of Accepted Transaction Sets Number of accepted Transaction Sets in a Functional Group     AK905 Functional Group Syntax Error Code Code indicating error found based on the syntax editing of the functional group header and/or trailer 1 Functional Group Not Supported 2 Functional Group Version Not Supported 3 Functional Group Trailer Missing 4 Group Control Number in the Functional Group Header and Trailer Do Not Agree 5 Number of Included Transaction Sets Does Not Match Actual Count 6 Group Control Number Violates Syntax     080 SE Transaction Set Trailer To indicate the end of the transaction set and provide the count of the transmitted segments (including the beginning (ST) and ending (SE) segments) SE*9*223~ M SE01 Number of Included Segments Total number of segments included in a transaction set including ST and SE segments     SE02 Transaction Set Control Number Identifying control number that must be unique within the transaction set functional group assigned by the originator for a transaction set

    Read the article

  • Visual Studio 2010 Beta 2 Startup Failures

    - by Rick Strahl
    I’ve been working with VS 2010 Beta 2 for a while now and while it works Ok most of the time it seems the environment is very, very fragile when it comes to crashes and installed packages. Specifically I’ve been working just fine for days, then when VS 2010 crashes it will not re-start. Instead I get the good old Application cannot start dialog: Other failures I’ve seen bring forth other just as useful dialogs with information overload like Operation cannot be performed which for me specifically happens when trying to compile any project. After a bit of digging around and a post to Microsoft Connect the solution boils down to resetting the VS.NET environment. The Application Cannot Start issue stems from a package load failure of some sort, so the work around for this is typically: c:\program files\Visual Studio 2010\Common7\IDE\devenv.exe /ResetSkipPkgs In most cases that should do the trick. If it doesn’t and the error doesn’t go away the more drastic: c:\program files\Visual Studio 2010\Common7\IDE\devenv.exe /ResetSettings is required which resets all settings in VS to its installation defaults. Between these two I’ve always been able to get VS to startup and run properly. BTW it’s handy to keep a list of command line options for Visual Studio around: http://msdn.microsoft.com/en-us/library/xee0c8y7%28VS.100%29.aspx Note that the /? option in VS 2010 doesn’t display all the options available but rather displays the ‘demo version’ message instead, so the above should be helpful. Also note that unless you install Visual C++ the Visual Studio Command Prompt icon is not automatically installed so you may have to navigate manually to the appropriate folder above. Cannot Build Failures If you get the Cannot compile error dialog, there is another thing that have worked for me: Change your project build target from Debug to Release (or whatever – just change it) and compile again. If that doesn’t work doing the reset steps above will do it for me. It appears this failure comes from some sort of interference of other versions of Visual Studio installed on the system and running another version first. Resetting the build target explicitly seems to reset the build providers to a normalized state so that things work in many cases. But not all. Worst case – resetting settings will do it. The bottom line for working in VS 2010 has been – don’t get too attached to your custom settings as they will get blown away quite a bit. I’ve probably been through 20 or more of these VS resets although I’ve been working with it quite a bit on an internal project. It’s kind of frustrating to see this kind of high level instability in a Beta 2 product which is supposedly the last public beta they will put out. On the other hand this beta has been otherwise rather stable and performance is roughly equivalent to VS 2008. Although I mention the crash above – crashes I’ve seen have been relatively rare and no more frequent than in VS 2008 it seems. Given the drastic UI changes in VS 2010 (using WPF for the shell and editor) I’m actually impressed that the product is as stable as it is at this point. Also I was seriously worried about text quality going to a WPF model, but thankfully WPF 4.0 addresses the blurry text issue with native font rendering to render text on non-cleartype enabled systems crisply. Anyway I hope that these notes are helpful to some of you playing around with the beta and running into problems. Hopefully you won’t need them :-}© Rick Strahl, West Wind Technologies, 2005-2010

    Read the article

  • Optional Parameters and Named Arguments in C# 4 (and a cool scenario w/ ASP.NET MVC 2)

    - by ScottGu
    [In addition to blogging, I am also now using Twitter for quick updates and to share links. Follow me at: twitter.com/scottgu] This is the seventeenth in a series of blog posts I’m doing on the upcoming VS 2010 and .NET 4 release. Today’s post covers two new language feature being added to C# 4.0 – optional parameters and named arguments – as well as a cool way you can take advantage of optional parameters (both in VB and C#) with ASP.NET MVC 2. Optional Parameters in C# 4.0 C# 4.0 now supports using optional parameters with methods, constructors, and indexers (note: VB has supported optional parameters for awhile). Parameters are optional when a default value is specified as part of a declaration.  For example, the method below takes two parameters – a “category” string parameter, and a “pageIndex” integer parameter.  The “pageIndex” parameter has a default value of 0, and as such is an optional parameter: When calling the above method we can explicitly pass two parameters to it: Or we can omit passing the second optional parameter – in which case the default value of 0 will be passed:   Note that VS 2010’s Intellisense indicates when a parameter is optional, as well as what its default value is when statement completion is displayed: Named Arguments and Optional Parameters in C# 4.0 C# 4.0 also now supports the concept of “named arguments”.  This allows you to explicitly name an argument you are passing to a method – instead of just identifying it by argument position.  For example, I could write the code below to explicitly identify the second argument passed to the GetProductsByCategory method by name (making its usage a little more explicit): Named arguments come in very useful when a method supports multiple optional parameters, and you want to specify which arguments you are passing.  For example, below we have a method DoSomething that takes two optional parameters: We could use named arguments to call the above method in any of the below ways: Because both parameters are optional, in cases where only one (or zero) parameters is specified then the default value for any non-specified arguments is passed. ASP.NET MVC 2 and Optional Parameters One nice usage scenario where we can now take advantage of the optional parameter support of VB and C# is with ASP.NET MVC 2’s input binding support to Action methods on Controller classes. For example, consider a scenario where we want to map URLs like “Products/Browse/Beverages” or “Products/Browse/Deserts” to a controller action method.  We could do this by writing a URL routing rule that maps the URLs to a method like so: We could then optionally use a “page” querystring value to indicate whether or not the results displayed by the Browse method should be paged – and if so which page of the results should be displayed.  For example: /Products/Browse/Beverages?page=2. With ASP.NET MVC 1 you would typically handle this scenario by adding a “page” parameter to the action method and make it a nullable int (which means it will be null if the “page” querystring value is not present).  You could then write code like below to convert the nullable int to an int – and assign it a default value if it was not present in the querystring: With ASP.NET MVC 2 you can now take advantage of the optional parameter support in VB and C# to express this behavior more concisely and clearly.  Simply declare the action method parameter as an optional parameter with a default value: C# VB If the “page” value is present in the querystring (e.g. /Products/Browse/Beverages?page=22) then it will be passed to the action method as an integer.  If the “page” value is not in the querystring (e.g. /Products/Browse/Beverages) then the default value of 0 will be passed to the action method.  This makes the code a little more concise and readable. Summary There are a bunch of great new language features coming to both C# and VB with VS 2010.  The above two features (optional parameters and named parameters) are but two of them.  I’ll blog about more in the weeks and months ahead. If you are looking for a good book that summarizes all the language features in C# (including C# 4.0), as well provides a nice summary of the core .NET class libraries, you might also want to check out the newly released C# 4.0 in a Nutshell book from O’Reilly: It does a very nice job of packing a lot of content in an easy to search and find samples format. Hope this helps, Scott

    Read the article

  • SQLAuthority News – Public Training Classes In Hyderabad 12-14 May – Microsoft SQL Server 2005/2008

    - by pinaldave
    After successfully delivering many corporate trainings as well as the private training Solid Quality Mentors, India is launching the Public Training in Hyderabad for SQL Server 2008 and SharePoint 2010. This is going to be one of the most unique and one-of-a-kind events in India where Solid Quality Mentors are offering public classes. I will be leading the training on Microsoft SQL Server 2005/2008 Query Optimization & Performance Tuning. This intensive, 3-day course intends to give attendees an in-depth look at Query Optimization and Performance Tuning in SQL Server 2005 and 2008. Designed to prepare SQL Server developers and administrators for a transition into SQL Server 2005 or 2008, the course covers the best practices for a variety of essential tasks in order to maximize the performance. At the end of the course, there would be daily discussions about your real-world problems and find appropriate solutions. Note: Scroll down for course fees, discount, dates and location. Do not forget to take advantage of Discount code ‘SQLAuthority‘. The training premises are very well-equipped as they will be having 1:1 computers. Every participant will be provided with printed course materials. I will pick up your entire lunch tab and we will have lots of SQL talk together. The best participant will receive a special gift at the end of the course. Even though the quality of the material to be delivered together with the course will be of extremely high standard, the course fees are set at a very moderate rate. The fee for the course is INR 14,000/person for the whole 3-day convention. At the rate of 1 USD = 44 INR, this fee converts to less than USD 300. At this rate, it is totally possible to fly from anywhere from the world to India and take the training and still save handsome pocket money. It would be even better if you register using the discount code “SQLAuthority“, for you will instantly get an INR 3000 discount, reducing the total cost of the training to INR 11,000/person for whole 3 days course. This is a onetime offer and will not be available in the future. Please note that there will be a 10.3% service tax on course fees. To register, either send an email to [email protected] or call +91 95940 43399. Feel free to drop me an email at [email protected] for any additional information and clarification. Training Date and Time: May 12-14, 2010 10 AM- 6 PM. Training Venue: Abridge Solutions, #90/B/C/3/1, Ganesh GHR & MSY Plaza, Vittalrao Nagar, Near Image Hospital, Madhapur, Hyderabad – 500 081. The details of the course is as listed below. Day 1 : Strengthen the basics along with SQL Server 2005/2008 New Features Module 01: Subqueries, Ranking Functions, Joins and Set Operations Module 02: Table Expressions Module 03: TOP and APPLY Module 04: SQL Server 2008 Enhancements Day 2: Query Optimization & Performance Tuning 1 Module 05: Logical Query Processing Module 06: Query Tuning Module 07:  Introduction to the Query Processor Module 08:  Review of common query coding which causes poor performance Day 3: Query Optimization & Performance Tuning 2 Module 09:  SQL Server Indexing and index maintenance Module 10:  Plan Guides, query hints, UDFs, and Computed Columns Module 11:  Understanding SQL Server Execution Plans Module 12: Real World Index and Optimization Tips Download the complete PDF brochure. We are also going to have SharePoint 2010 training by Joy Rathnayake on 10-11 May. All the details for discount applies to the same as well. Reference : Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, SQL Training, SQLAuthority News, T SQL, Technology

    Read the article

  • OBIEE 11.1.1 - User Interface (UI) Performance Is Slow With Internet Explorer 8

    - by Ahmed A
    The OBIEE 11g UI is performance is slow in IE 8 and faster in Firefox.  For VPN or WAN users, it takes long time to display links on Dashboards via IE 8. Cause is IE 8 generates many HTTP 304 return calls and this caused the 11g UI slower when compared to the Mozilla FireFox browser. To resolve this issue, you can implement HTTP compression and caching. This is a best practice.Why use Web Server Compression / Caching for OBIEE? Bandwidth Savings: Enabling HTTP compression can have a dramatic improvement on the latency of responses. By compressing static files and dynamic application responses, it will significantly reduce the remote (high latency) user response time. Improves request/response latency: Caching makes it possible to suppress the payload of the HTTP reply using the 304 status code.  Minimizing round trips over the Web to re-validate cached items can make a huge difference in browser page load times. This screen shot depicts the flow and where the compression and decompression occurs: Solution: a. How to Enable HTTP Caching / Compression in Oracle HTTP Server (OHS) 11.1.1.x 1. To implement HTTP compression / caching, install and configure Oracle HTTP Server (OHS) 11.1.1.x for the bi_serverN Managed Servers (refer to "OBIEE Enterprise Deployment Guide for Oracle Business Intelligence" document for details). 2. On the OHS machine, open the file HTTP Server configuration file (httpd.conf) for editing. This file is located in the OHS installation directory.For example: ORACLE_HOME/Oracle_WT1/instances/instance1/config/OHS/ohs13. In httpd.conf file, verify that the following directives are included and not commented out: LoadModule expires_module "${ORACLE_HOME}/ohs/modules/mod_expires.soLoadModule deflate_module "${ORACLE_HOME}/ohs/modules/mod_deflate.so 4. Add the following lines in httpd.conf file below the directive LoadModule section and restart the OHS: Note: For the Windows platform, you will need to enclose any paths in double quotes ("), for example:Alias "/analytics ORACLE_HOME/bifoundation/web/app"<Directory "ORACLE_HOME/bifoundation/web/app"> Alias /analytics ORACLE_HOME/bifoundation/web/app#Pls replace the ORACLE_HOME with your actual BI ORACLE_HOME path<Directory ORACLE_HOME/bifoundation/web/app>#We don't generate proper cross server ETags so disable themFileETag noneSetOutputFilter DEFLATE# Don't compress imagesSetEnvIfNoCase Request_URI \.(?:gif|jpe?g|png)$ no-gzip dont-vary<FilesMatch "\.(gif|jpeg|png|js|x-javascript|javascript|css)$">#Enable future expiry of static filesExpiresActive onExpiresDefault "access plus 1 week"     #1 week, this will stops the HTTP304 calls i.e. generated by IE 8Header set Cache-Control "max-age=604800"</FilesMatch>DirectoryIndex default.jsp</Directory>#Restrict access to WEB-INF<Location /analytics/WEB-INF>Order Allow,DenyDeny from all</Location> Note: Make sure you replace above placeholder "ORACLE_HOME" to your correct path for BI ORACLE_HOME.For example: my BI Oracle Home path is /Oracle/BIEE11g/Oracle_BI1/bifoundation/web/app Important Notes: Above caching rules restricted to static files found inside the /analytics directory(/web/app). This approach is safer instead of setting static file caching globally. In some customer environments you may not get 100% performance gains in IE 8.0 browser. So in that case you need to extend caching rules to other directories with static files content. If OHS is installed on separate dedicated machine, make sure static files in your BI ORACLE_HOME (../Oracle_BI1/bifoundation/web/app) is accessible to the OHS instance. The following screen shot summarizes the before and after results and improvements after enabling compression and caching:

    Read the article

  • Listen to Online Radio with Antenna

    - by Asian Angel
    Are you looking for some fresh new music to listen to at home or at work? With Antenna you can listen to online radio stations from all over the world. Note: Requires Adobe AIR (download link at bottom of article). Antenna in Action Once you have completed the installation and started Antenna up this is the window that you will see. The left side will have a “browsing pane” where you can search for the stations that you would like to listen to using the various categories. Based on the stations that you choose the background map will change location to match the stations locations. Here is a closer look at the “Categories Bar”. For our first example we used the “Country Category” to find our first station to listen to. When you choose a country you will be presented with a list of the stations available for that country. To start listening to a particular station just double click on the appropriate entry line. A closer look at the “browser pane” with our first station playing. Notice the “Reliability Indicator” that will be available for each listing…some may be better than others and you can use this to choose the best streaming stations from the list. In the upper left corner you will notice three icons…each will open a small pop-up window with a specific purpose. The first icon will open up the “About Window”. If you need to contact Antenna’s creator or would like to place a request for a station to be added to the app then this is the best way to do it. The second icon will open up a Antenna specific chat window. The third icon will allow you to set a default location and make adjustments to some of the app’s settings. Recording Audio The “Recording Function” is the only area where we experienced some “quirkiness” with the app. To start recording press the “Round White Button”… Note: Based on feedback on the app creator’s webpage some people have experienced the same problem as we did during our tests with the app failing to complete the recordings. Hopefully this bug will be fixed with the next release. Once recording has started the button will turn red. Click on the button again to stop recording. Once you have stopped recording you will see the following message window appear and the main window will be shaded over with a whitish color until you click “OK”. Conclusion Regardless of the slight quirkiness in recording online music Antenna more than makes up for it with the terrific selection of online stations and streaming capability. New fresh music for you to listen to is only a click or two away… Links Download Antenna (Antenna Homepage) Download Antenna at Softpedia Download Adobe AIR Similar Articles Productive Geek Tips Listen to Local FM Radio in Windows 7 Media CenterListen to Over 100,000 Radio Stations in Windows Media CenterListen To XM Radio with Windows Media Center in Windows 7Listen and Record Over 12,000 Online Radio Stations with RadioSureWeekend Fun: Watch Television on Your PC with AnyTV TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 Will it Blend? iPad Edition Penolo Lets You Share Sketches On Twitter Visit Woolyss.com for Old School Games, Music and Videos Add a Custom Title in IE using Spybot or Spyware Blaster When You Need to Hail a Taxi in NYC Live Map of Marine Traffic

    Read the article

< Previous Page | 71 72 73 74 75 76 77 78 79 80 81 82  | Next Page >