Search Results

Search found 8812 results on 353 pages for 'tweak ie'.

Page 78/353 | < Previous Page | 74 75 76 77 78 79 80 81 82 83 84 85  | Next Page >

  • Autounattend.xml not being recognized in VirtualBox

    - by beagle
    I am working my way through the steps on this page to prepare an unattended installation of Windows 7 Enterprise x64 for purposes of a college assignment which simply requires the process to be carried out and documented. Both the "technician" and "reference" computers are virtual machines created in VirtualBox 4.3.12, as will be the destination computer. I seem to have successfully completed Step 1, building an Autounattend.xml answer file using Windows System Image Manager, in as far as the answer file validates successfully. The problem arises when I try to install Windows on the reference machine from the DVD image in conjunction with the Autounattend file on a USB drive. I have tried a couple of different USB devices, and the devices themselves seem to be recognized, but the answer file does not, as instead of taking the configuration settings from the file the user interface appears as in a manual installation. Has anyone come across this problem or a solution? The xml created by Windows SIM is below for reference in case the problem is with the file itself. <?xml version="1.0" encoding="utf-8"?> <unattend xmlns="urn:schemas-microsoft-com:unattend"> <settings pass="oobeSystem"> <component name="Microsoft-Windows-Deployment" processorArchitecture="amd64" publicKeyToken="31bf3856ad364e35" language="neutral" versionScope="nonSxS" xmlns:wcm="http://schemas.microsoft.com/WMIConfig/2002/State" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"> <Reseal> <Mode>Audit</Mode> </Reseal> </component> <component name="Microsoft-Windows-Shell-Setup" processorArchitecture="amd64" publicKeyToken="31bf3856ad364e35" language="neutral" versionScope="nonSxS" xmlns:wcm="http://schemas.microsoft.com/WMIConfig/2002/State" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"> <OOBE> <HideEULAPage>true</HideEULAPage> <ProtectYourPC>3</ProtectYourPC> </OOBE> </component> </settings> <settings pass="windowsPE"> <component name="Microsoft-Windows-International-Core-WinPE" processorArchitecture="amd64" publicKeyToken="31bf3856ad364e35" language="neutral" versionScope="nonSxS" xmlns:wcm="http://schemas.microsoft.com/WMIConfig/2002/State" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"> <SetupUILanguage> <UILanguage>en-IE</UILanguage> </SetupUILanguage> <InputLocale>en-IE</InputLocale> <SystemLocale>en-IE</SystemLocale> <UILanguage>en-IE</UILanguage> <UserLocale>en-IE</UserLocale> </component> <component name="Microsoft-Windows-Setup" processorArchitecture="amd64" publicKeyToken="31bf3856ad364e35" language="neutral" versionScope="nonSxS" xmlns:wcm="http://schemas.microsoft.com/WMIConfig/2002/State" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"> <DiskConfiguration> <Disk wcm:action="add"> <CreatePartitions> <CreatePartition wcm:action="add"> <Order>1</Order> <Size>300</Size> <Type>Primary</Type> </CreatePartition> <CreatePartition wcm:action="add"> <Order>2</Order> <Extend>true</Extend> <Type>Primary</Type> </CreatePartition> </CreatePartitions> <ModifyPartitions> <ModifyPartition wcm:action="add"> <Active>true</Active> <Format>NTFS</Format> <Label>System</Label> <Order>1</Order> <PartitionID>1</PartitionID> </ModifyPartition> <ModifyPartition wcm:action="add"> <Format>NTFS</Format> <Label>Windows</Label> <Order>2</Order> <PartitionID>2</PartitionID> </ModifyPartition> </ModifyPartitions> <DiskID>0</DiskID> <WillWipeDisk>true</WillWipeDisk> </Disk> <WillShowUI>OnError</WillShowUI> </DiskConfiguration> <ImageInstall> <OSImage> <InstallTo> <DiskID>0</DiskID> <PartitionID>2</PartitionID> </InstallTo> <InstallToAvailablePartition>false</InstallToAvailablePartition> <WillShowUI>OnError</WillShowUI> </OSImage> </ImageInstall> <UserData> <ProductKey> <WillShowUI>OnError</WillShowUI> </ProductKey> <AcceptEula>true</AcceptEula> </UserData> </component> </settings> <settings pass="specialize"> <component name="Microsoft-Windows-IE-InternetExplorer" processorArchitecture="amd64" publicKeyToken="31bf3856ad364e35" language="neutral" versionScope="nonSxS" xmlns:wcm="http://schemas.microsoft.com/WMIConfig/2002/State" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"> <Home_Page>http://www.example.com</Home_Page> </component> </settings> <cpi:offlineImage cpi:source="wim://technician/users/user/desktop/install.wim#Windows 7 ENTERPRISE" xmlns:cpi="urn:schemas-microsoft-com:cpi" />

    Read the article

  • Pasting to Excel from Word - stop a Word new line being converted into a new cell

    - by Sean McRaghty
    So I have a table in MS Word which has two columns. In the second column the text is spread on multiple lines, ie I have pressed 'Enter' to achieve this. When I paste into Excel, it converts these separate lines into separate cells. What I want it to do is to keep the lines in the same cell, just on different lines, ie what would happen if I were to press Alt+Enter in a cell in excel. How would I go about this?

    Read the article

  • IE9 Error: There was a pr?blem sending the command to the program

    - by HK1
    I'm working on a new/fresh Windows 7 32bit machine that now has IE9 installed. The user is using the Dell Stardock application as his primary "desktop" (all his links there). When we place an internet link there and click on it we get the following error message: There was a problem sending the command to the program. To me this indicates that IE9 is having trouble going to the website we want to go to, which should get passed as a parameter to the browser when it opens. I don't think this is a StarDock/ObjectDock problem because we also have some other problems with internet links. For example, we cannot move an internet link from the Desktop to the Quick Launch on the task bar. When we do try, it forces us to put the link with the IE icon as part of the IE menu instead of allowing us to have a shortcut there as it's own entry. I should mention however, that links on the desktop and in the taskbar do work as we expect them too (without showing the above error message). It appears that this problem started after installing Windows Updates. Since we installed a whole bunch of updates at once I have no idea which one caused the problem. I did have Google Chrome installed but I uninstalled it since the user wants to use IE. The problem started before I uninstalled Chrome. I also reset the browser settings on IE9. It didn't help. Next I uninstalled IE9 which took me back to IE8. This actually did resolve the problem but the problem came back as soon as I installed IE9 again. We have Verizon Internet Security installed. It's actually a McAfee product rebranded to look like Verizon. I'm not real crazy over this software but the customer has a subscription so we're not planning to change it. I have no reason to believe that this is causing the problem and yet I know that security software is often to blame for strange issues. I've looked at the registry settings for the following keys and everything appears to be ok for every single one of them: HKEY_CLASSES_ROOT\.htm HKEY_CLASSES_ROOT\.html HKEY_CLASSES_ROOT\http\shell\open\command HKEY_CLASSES_ROOT\http\shell\open\ddeexec\Application HKEY_CLASSES_ROOT\https\shell\open\command HKEY_CLASSES_ROOT\https\shell\open\ddeexec\Application HKEY_CLASSES_ROOT\htmlfile\shell\open\command HKEY_CLASSES_ROOT\Microsoft.Website\Shell\Open\Command Edit1: I've found two potential solutions but I won't be able to try them until tomorrow. One is to disable the "Windows Font Cache" service. Another is to clear IE cache and browsing history. I won't be able to try out either solution until tomorrow since this is a remote client's machine. I see there are lots of other suggestions online but if you take the time to read them through you'll see that the other suggestions didn't fix the problem.

    Read the article

  • Setting up a fake email address to trap spammers

    - by Brent
    I have heard it suggested that we set up a special email address, with it's only purpose being to be harvested. Then blacklisting every sender that targets this address. I'm wondering: if anyone else has tried this how do you go about doing it (ie - put the address in a hidden field on your website - or better ways?) does it work? Is there anything to watch out for when trying this (ie. legitimate senders using harvested addresses?)

    Read the article

  • script runtime errors

    - by james
    i have checked disable scripting (both) in IE tools (and it stays checked) and am still getting frequent runtime error boxes. it happens with chrome open, but not IE. any ideas? thanks

    Read the article

  • How can I monitor URLs being requested by components in web apps running in Internet Explorer?

    - by Tahtah
    Hi I'm using a particular web app which for some strange reason runs only in IE and not in Firefox. I need to see which URLs are being fetched by internal components in the web app, such as AJAX requests and video sources being loaded in a video player. In Firefox I would have used Firebug... is there any tool I can use to see (not necessarily in real time or with a nice GUI) which URLs were requested by IE? Thanks

    Read the article

  • Migrating Split Access Database from one domain to another (not working, details in Q)

    - by Expo_Rob
    Some background: I'm a programmer, not a network administrator, who has been asked to migrate some accounting software (Integrated Office Accounting version 3.2) from an existing domain (OLD_NETWORK) to a new domain (NEW_NETWORK). No-body at the office knows how it works under the hood. It is a split Access 2000 database with the back-end shared and on a file server (which is also the DC) using mapped drives. The DC is NT Server 4 SP 6. The new server is server 2003. The two networks are running independently (ie: two computers on each desk). I have been able to get new computers set up on NEW_NETWORK and working with the IOA software just perfectly but for one problem: The company here uses other entirely separate databases which access the tables IOA maintains (specifically the 'customers' table) via links. To switch between these systems, you press F11 then File-Open the appropriate database and away you go (this is necessary to maintain the permissions that the IOA system uses to protect the customers table). The entire database is Access 2000, the links go to other Access databases, SQL-Server is not involved in any way, nor is a migration to SQL server likely. If I can't migrate anything over, everything will stay as it is, and the NEW_NETWORK computers will not be used. The problem: When I try and update these seperate databases (I shall call one "BANK_ACCOUNT", but the name does not matter), it says "this recordset cannot be updated". It also will sometimes not pull information out of the 'customers' table (ie: date_entered) when looking at a report of everyone who opened a bank account on a certain day (ie: today). I have tried: Giving 'everyone' full control via. shared directory permissions Giving 'everyone' full control on a file system level Checking the permissions within Access (everyone has full read/write on all tables) Copying the entire server contents from one file server to another (ie: xcopy everything) Copying the entire local client files from one computer to another, putting them in the exact same position in the file system, with the same permissons (or full control to 'everyone'). Running as an Administrator Taking one of the NEW_NETWORK computers, having it join OLD_NETWORK and run the software (direct copy from a working system with identical drive mappings), this did not work Weeping openly My Question: Is there anything else I can try? (sorry for this being so long)

    Read the article

  • WatiN LogonDialogHandlers not working correctly in Windows 7

    - by Clint
    I have recently updated to Windows 7, VS2010 and IE8. We have an automation suite running tests against IE using WatiN. These tests require the logon dialog handler to be used in order to log different AD Users into the IE Browser. This works perfectly when using Windows XP and IE8, but now using Windows 7 has resulted in the Windows Security dialog box no longer being recognised, the dialogue box is just being ignored. This is the method being used to startup the browser: public static Browser StartBrowser(string url, string username, string password) { Browser browser = new IE(); WatiN.Core.DialogHandlers.LogonDialogHandler ldh = new WatiN.Core.DialogHandlers.LogonDialogHandler(username, password); browser.DialogWatcher.Add(ldh); browser.GoTo(url); return browser; } any suggestions or help would be greatly appreciated...

    Read the article

  • Using C# WATIN, how do I get the value of a INPUT tag html element?

    - by djangofan
    Using C# WATIN, how do I get the value of the second occurence of a INPUT tag html element on a page? I've tried a whole bunch of things and haven't succeeded. The debugger isn't giving me any obvious way to get element[1] among the 4 that returned. Console.WriteLine(ie.Element(Find.ByClass("myclass")).GetAttributeValue("value") ) ; // works but prints the value of the 1st of 4 input elements on the page Console.WriteLine(ie.ElementsWithTag("input", "text").Length.ToString() ); // returns the number 4 Console.WriteLine( ie.Element(Find.ByName("login")).GetAttributeValue("value") ); // works but its not safe since its possible there might be two elements with the name login Basically, I want to be able to select the input element by its array index.

    Read the article

  • Force "Internet Explorer 8" browser mode in intranet

    - by Dennis Cheung
    There are "Internet Explorer 8", "Internet Explorer 8 Compatibility Mode", and IE7 mode in IE8. However, the default setting in IE make all intranet website use "IE8 Compatibility Mode" even I have setted doctype, the meta tag, http header as suggested to force it into IE8 mode. I have <!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN" "http://www.w3.org/TR/html4/loose.dtd" and <meta http-equiv="X-UA-Compatible" content="IE=8" But it still goes into "IE8 Compatibility Mode", without any changes in IE setting. How to force it into pure "IE8" mode, without change any browser's setting? PS. I am not talking "document mode" here.

    Read the article

  • remember password is not filling the password field automatically

    - by coder247
    IE is not filling the password field automatically when i click on the bookmarked url. But it's working on firefix,chrome etc. I tried with autocomplete="on" but no use. IE will fill the password only When i select a usename from the possible user names which the browser had kept for each login. And when i logout, user name will be filled in without the password. ( only in IE for other browsers both are filled). Thanks....

    Read the article

  • Row concat from this query

    - by Álvaro G. Vicario
    I have this query: SELECT DISTINCT IM.EDIFICIOS_ID, TI.TITULAR FROM IMPORTACION IM INNER JOIN I_EDIFICIO IE ON IM.IMPORTACION_ID=IE.IMPORTACION_ID INNER JOIN I_EDIFICIO_TITULAR ET ON IM.IMPORTACION_ID=ET.IMPORTACION_ID AND IE.EDIFICIO_ID=ET.EDIFICIO_ID INNER JOIN I_TITULAR TI ON IM.IMPORTACION_ID=TI.IMPORTACION_ID AND ET.TITULAR_ID=TI.TITULAR_ID WHERE TI.TITULAR IS NOT NULL AND TI.TITULAR<>'' ORDER BY IM.EDIFICIOS_ID, TI.TITULAR; that returns this result set: EDIFICIOS_ID TITULAR ------------ ------------------ 1911 Ana María García 1911 Anselmo Piedrahita 1911 Manuel López 2594 Carlos Pérez 2594 Felisa García 6865 Carlos Pérez 6865 Felisa García 8428 Carlos Pérez I want to concatenate the values from TITULAR for each EDIFICIOS_ID, so I get this: EDIFICIOS_ID TITULAR ------------ ------------------ 1911 Ana María García; Anselmo Piedrahita; Manuel López 2594 Carlos Pérez; Felisa García 6865 Carlos Pérez; Felisa García 8428 Carlos Pérez I'm trying to use the FOR XML PATH trick. I've used it in the past but, since I can't really understand how it works, I can't figure out how to apply it to this specific case. Can you provide me with some ideas?

    Read the article

  • Reuse another ASP.NET session (set Session ID)

    - by queen3
    My problem is that when I open web application from Outlook in a separate IE window, the ASP.NET session is lost. This is (as described in several places) because in-memory cookie is lost. So it goes like this: User works with ASP.NET web application in Outlook, and this stores some info in ASP.NET session User clicks Print to open new IE window with print-ready data The new window has different ASP.NET session ID and can't access old data. I think, maybe, if I pass ASP.NET session ID to new IE window, I can somehow "attach" to that session? Tell ASP.NET that this is the one that I need to be current?

    Read the article

  • IE8 and P3P problems again,

    - by MSolution
    Have been browsing across the net, and seems everyone who got into this mess, really slogged to get out of it,... and now my turn! http://stackoverflow.com/questions/999534/ie-p3p-iframe-and-blocked-cookies-works-until-page-host-page-has-personal-info been reading alot, and i have a very simple p3p policy here: http: // bit.ly/cCyGi5 and corresponding P3P compact policy: P3P: CP="COM DEM INT NAV OTC PRE PUR STA NOI DSP COR ADMi DEVi OUR BUS" I have validated my P3P policy via the validator at w3c, I have tried "privacy bird" IE extension, and it says my P3P.xml matches with my privacy settings, and has no conflict, my compact policy matches with my P3P policy, coz some where i read IE7 matches the two!!! If i lower my privacy settings in IE, the cookies get restricted, and if i further lower it to allow all, it gets thru, so it is my P3P compact policy the coz, and needs fixing. If someone can guide me in the right direction, or if i can hire someone for an hour or two to look into it. M.

    Read the article

  • IIS URL Rewriting for all Inbound URLs?

    - by Rob Burke
    Hopefully a simple question although one I have found impossible to answer myself using the Googles! I have a website on IIS with the URL http://www.contoso.com/ which points to C:\www\public\ There has been a forced directory restructure so now all of the data (Default.aspx, Product.aspx, etc.) that originally resided in C:\www\public\ now resides in C:\www\public\en\ie\ - however, the IIS website document root is still C:\www\public\ So, essentially, I have a lot of inbound links to http://www.contoso.com/Product.aspx?id=1 (etc.) which are now returning 404 errors - the correct link is now http://www.contoso.com/en/ie/Product.aspx?id=1 Please consider that I can make no changes to the directory structure or the IIS document root... so must solve this issue using URL rewriting. Is it possible to capture all requests to contoso.com/* and rewrite them to contoso.com/en/ie/* ??

    Read the article

  • AJAX CascadingDropdown - Setting the selected index - C# - ASP.NET

    - by rpm1984
    Hi, I have a CascadingDropDown on an ASP.NET page. Now, the prompt text is "Select State". (list of states). However, on a different version of this page (ie querystring), i might want to set the selected index to "California" for example. How can i do this? The web service used by the ajax control (ie GetStates) gets invoked at the same time the jquery document.ready function is triggered (ie asynchronously). So when i try and set the selected index in jquery, the items are not yet bound. Is there a way to attach a handler to the ajax dropdown so that i can set the selected index once the webservice call has completed, and the items are bound? Thanks in advance.

    Read the article

  • Where to get MSDN Help Viewer for 2010 like earlier MSDN with Index, Tree and one window?

    - by Akash Kava
    I upgraded to Visual Studio 2010 RC, and I remember filling one big form for MSDN help improvement campaign and I was wondering I will get to see a Help Viewer like MSDN included in Visual Studio 2008, which included One Program (Not IE), Index and the way to view preferred language setting. Google results shows that there were headlines that Microsoft Help Viewer released for 2010 RC, but where is it? is it the same one which opens in IE and has absolute difficult way to view it? Current MSDN opening in IE is so inconvenient, there is no index, there is no grouping of content, like I typed search for TextBox and it showed up for ASP.NET, WinForms and I got lost to find out the reference in multiple pages for search results.

    Read the article

  • List of Selenium RC browser launchers

    - by jacksenechal
    I am trying to find a full list of Selenium RC browser launchers. So far I've not been able to find any documentation that lists them all. I've gathered the following ones from various sources. *iexplore - Launches IE *firefox - Launches Firefox *safari - Launches Safari *opera - Launches Opera *chrome - Launches special Firefox profile with elevated security privileges, to bypass Javascript security errors *iehta - Launches IE with elevated security privileges *piiexplore - Launches IE in proxy injection mode *pifirefox - Launches Firefox in proxy injection mode *custom - Launches your own custom browser executable Are there any others lurking out there? Is there any source of documentation on how each one is used?

    Read the article

  • Preferred way of using UiBinder with multiple screens

    - by arinte
    We have a GWT app that has multiple screens, based off of a menu. So App loads user sees Do This Do That Each menu item loads a different screen. What is the best way to switch the screens. Right now what I do roughly is RootPanel.get(CONTENT).remove(menu); RootPanel.get(CONTENT).add(new DoThisScreen()); I ask this because it seems on IE 8 (and I am sure 7,6) that the DoThisScreen is basically not recognize by IE's Developer Tool (wannabe firebug tool, when you press F12). Using IE's dev tool I tell it to highlight a textbox in the DoThisScreen, for some reason it won't highlight it or list it in the html.

    Read the article

  • Why does this window object not have the eval function?

    - by Motti
    I ran into an interesting (?) problem in the YUI rich edit demo on IE. When looking at the window object for the content editable frame used as the browser I see that the eval function is undefined (by running the following). javascript:alert(document.getElementById("editor_editor").contentWindow.eval) This only happens on IE (I checked on IE6 and IE8), and it doesn't happen on Firefox or Chrome. All the other window functions and properties seem to be in order, now I realise that eval is not really defined on the window but on the global object but my understanding was that in browsers the window is the global object (also eval does appear on all other windows so why not on this one?). Does anyone know if this is a know bug/limitation in IE and how I can get to eval in the context of the global object of this frame? (I need the side effects to be available to anything running from within this frame).

    Read the article

  • When should I observe javascript events on window vs. document vs. document.body?

    - by brahn
    I'm using prototype.js for my web app, and I have everything running on chrome, safari, and firefox. I am now working on IE8 compatibility. As I've been debugging in IE, I've noticed that there are javascript events for which I have previously set an observer on the window, e.g. Event.observe(window, eventType, function () {...}); (where eventType might be "dom:loaded", "keypress", etc.) and it works just fine in Chrome/Safari/Firefox. However, in IE the observer never fires. In at least some cases I could get this to work on IE by instead placing the observer on something other than window, e.g. document (in the case of "dom:loaded") or document.body (in the case of "keypress"). However, this is all trial-and-error. Is there some more systematic way to determine where to place these observers such that the results will be cross-browser compatible? Thanks!

    Read the article

  • Javascript cross-domain web request fails with Status=0?

    - by Tav
    Yes, I know the following code does not work in IE. I know IE expects me to use XDomainRequest() instead. I don't care about that. This is firefox only. I'm trying to do a cross-domain web request in firefox javascript. I keep getting a status of 0. Does anyone know why? var url = "http://newyork.craigslist.org"; var xdr = new XMLHttpRequest(); //Yes, I know IE expects XDomainRequest. Don't care xdr.onreadystatechange = function() { if (xdr.readyState == 4) { alert(xdr.status); //Always returns 0! And xdr.responseText is blank too } } xdr.open("get", url, true); xdr.send(null); Shouldn't that work?

    Read the article

< Previous Page | 74 75 76 77 78 79 80 81 82 83 84 85  | Next Page >