Search Results

Search found 21212 results on 849 pages for 'message queueing'.

Page 8/849 | < Previous Page | 4 5 6 7 8 9 10 11 12 13 14 15  | Next Page >

  • Using a WCF Message Inspector to extend AppFabric Monitoring

    - by Shawn Cicoria
    I read through Ron Jacobs post on Monitoring WCF Data Services with AppFabric http://blogs.msdn.com/b/endpoint/archive/2010/06/09/tracking-wcf-data-services-with-windows-server-appfabric.aspx What is immediately striking are 2 things – it’s so easy to get monitoring data into a viewer (AppFabric Dashboard) w/ very little work.  And the 2nd thing is, why can’t this be a WCF message inspector on the dispatch side. So, I took the base class WCFUserEventProvider that’s located in the WCF/WF samples [1] in the following path, \WF_WCF_Samples\WCF\Basic\Management\AnalyticTraceExtensibility\CS\WCFAnalyticTracingExtensibility\  and then created a few classes that project the injection as a IEndPointBehavior There are just 3 classes to drive injection of the inspector at runtime via config: IDispatchMessageInspector implementation BehaviorExtensionElement implementation IEndpointBehavior implementation The full source code is below with a link to the solution file here: [Solution File] using System; using System.Collections.Generic; using System.Linq; using System.Web; using System.ServiceModel.Dispatcher; using System.ServiceModel.Channels; using System.ServiceModel; using System.ServiceModel.Configuration; using System.ServiceModel.Description; using Microsoft.Samples.WCFAnalyticTracingExtensibility; namespace Fabrikam.Services { public class AppFabricE2EInspector : IDispatchMessageInspector { static WCFUserEventProvider evntProvider = null; static AppFabricE2EInspector() { evntProvider = new WCFUserEventProvider(); } public object AfterReceiveRequest( ref Message request, IClientChannel channel, InstanceContext instanceContext) { OperationContext ctx = OperationContext.Current; var opName = ctx.IncomingMessageHeaders.Action; evntProvider.WriteInformationEvent("start", string.Format("operation: {0} at address {1}", opName, ctx.EndpointDispatcher.EndpointAddress)); return null; } public void BeforeSendReply(ref System.ServiceModel.Channels.Message reply, object correlationState) { OperationContext ctx = OperationContext.Current; var opName = ctx.IncomingMessageHeaders.Action; evntProvider.WriteInformationEvent("end", string.Format("operation: {0} at address {1}", opName, ctx.EndpointDispatcher.EndpointAddress)); } } public class AppFabricE2EBehaviorElement : BehaviorExtensionElement { #region BehaviorExtensionElement /// <summary> /// Gets the type of behavior. /// </summary> /// <value></value> /// <returns>The type that implements the end point behavior<see cref="T:System.Type"/>.</returns> public override Type BehaviorType { get { return typeof(AppFabricE2EEndpointBehavior); } } /// <summary> /// Creates a behavior extension based on the current configuration settings. /// </summary> /// <returns>The behavior extension.</returns> protected override object CreateBehavior() { return new AppFabricE2EEndpointBehavior(); } #endregion BehaviorExtensionElement } public class AppFabricE2EEndpointBehavior : IEndpointBehavior //, IServiceBehavior { #region IEndpointBehavior public void AddBindingParameters(ServiceEndpoint endpoint, BindingParameterCollection bindingParameters) {} public void ApplyClientBehavior(ServiceEndpoint endpoint, ClientRuntime clientRuntime) { throw new NotImplementedException(); } public void ApplyDispatchBehavior(ServiceEndpoint endpoint, EndpointDispatcher endpointDispatcher) { endpointDispatcher.DispatchRuntime.MessageInspectors.Add(new AppFabricE2EInspector()); } public void Validate(ServiceEndpoint endpoint) { ; } #endregion IEndpointBehavior } }     [1] http://www.microsoft.com/downloads/details.aspx?FamilyID=35ec8682-d5fd-4bc3-a51a-d8ad115a8792&displaylang=en

    Read the article

  • Troubleshooting Microsoft Message Queuing Issues on Microsoft Lync Server 2010

    - by John Breakwell
    This blog post sounds specific but most of the troubleshooting tips can be applied to other scenarios: Troubleshooting Microsoft Message Queuing Issues on Microsoft Lync Server 2010 Microsoft Message Queuing (MSMQ) plays an important role in the Microsoft Lync Server 2010 Monitoring/Archiving server infrastructure: in a distributed network environment, MSMQ is used to transmit data from agents located on other servers (such as Front End Servers) to Monitoring/Archiving servers. The purpose of this article is to help you discover the root cause of any MSMQ problems that you might encounter, and to provide suggested ways to fix those problems. Microsoft Lync Server is the new name for Microsoft Office Communications Server. It’s good to see a major product make use of MSMQ – there aren’t many in the public eye (Symantec’s Enterprise Vault comes to mind).

    Read the article

  • Regardless of battery charge, when unplugged Ubuntu displays critical battery message and hibernates

    - by Chesc
    Regardless of battery charge, when unplugged Ubuntu displays critical battery message and hibernates. I can only seem to change it to either shutdown or hibernate. This does not happen when using windows 7 on the same computer. Windows 7 gives a good few hours on a full charge indicating that it is not a battery problem. Any help? I really don't want to have to use windows but its kinda pointless having a netbook that doesn't work when not plugged in! I'm using a toshiba nb250 and the most up to date 11.10 ubuntu distro. I use to get the critical battery message before on the previous ubuntu but it never shut down or hibernated my computer.

    Read the article

  • "initialization error: class file has wrong version" message in JDeveloper 10.1.2.x

    - by [email protected]
    The "initialization error: class file has wrong version" has become a somewhat recurrent error message thrown by JDeveloper 10.1.2.x as newer JDKs have been released in the last years. Note that JDeveloper 10.1.2 was developed to run with JDK 1.4.2. The reasons for this error message to be thrown include: A JDK version higher than 1.4.2 is being used and some unexpected incompatibility conflicts can occur because of that Some of the libraries used on the workspace and/or project were compiled with newer JDK version So, it is strongly recommended to use newer JDeveloper versions (10.1.3 - 11g) for newer JDKs. JDeveloper 10.1.2 will be desupported in December 2010 (or later depending on the support contract). Further information about this can be seen at http://www.oracle.com/support/library/brochure/lifetime-support-middleware.pdf

    Read the article

  • Why should i write a commit message?

    - by acidzombie24
    Why should i write a commit message? I dont want to and i think its stupid every single time. A gui frontend i use which will go unnamed forces you to do it. I hear other doing it everytime even if they are using the VCS on the command line. If i commit several times a day and havent finish a feature what am i writing about? I ONLY ever write a message after many comments and i feel its time for a mini tag or when i do an actual tag. Am i right or am i missing something? also i am using a distributed system

    Read the article

  • JAVA Script confirmation message on button click

    - by Rajneesh Verma
    HI, some times we stuck that how to show confirmation message to do a server side event for example to delete record message should be “Are you sure you want to delete?” so the simplest option is: Code Snippet < asp : Button ID ="Button1" runat ="server" OnClientClick ="return confirm('Are you sure you want to delete?');" onclick ="Button1_Click" Text ="Delete" /> A small tip :) Thanks…...(read more)

    Read the article

  • "Fatal Error" message during boot process

    - by Denja
    I'm running Ubuntu 10.10 with ATI proprietary FGLRX graphic drivers When I boot, I can see this very quick message appearing; I don't have time to read it: **Fatal Error ..................................**(&@something i cant read) I searched through the log file in /var/log/ in order to find what is wrong and I did find something in the /var/log/Xorg.1.log: 21:31:08 [ 15.734] (--) using VT number 1 [ 204.647] Fatal server error: [ 204.647] xf86OpenConsole: VT_WAITACTIVE failed: Interrupted system call [ 204.647] [ 204.647] Please consult the The X.Org Foundation support at http://wiki.x.org for help. [ 204.647] Please also check the log file at "/var/log/Xorg.1.log" for additional information. [ 204.647] But this is already Xorg.1.log. And there is a Xorg.0.log also & Xorg.0.log.old but it doesnt have any error in it. My system seems to work properly and it seems its not affected by this But how do I correct this message? Any suggestions?

    Read the article

  • Line break and also getting space in HL7 message

    - by user1280098
    My BizTalk receive XML message as a input message. I am converting that message to HL7 message using Transform in orchestration. Now if input message consists of any empty field in any of the node, the HL7 message breaks up at that postion and also include space in that message. Can anyone help me to resolve this issue? following is my HL7 message: Note --- Copy this message in Textpad to get to know exact space in it MSH|^~\&|EEHR^bbbbbbbbbb|aaaaaaaaaaaaaaaaa^12699^DNS|KYIR|CDP|201103060733||VXU^V04|14962|P|2.3.1|||| PID|1||765874316^^^^SS||ssssss^anan^T|wwwww^^^^^^M|20100217|M||2135-2^YYYYYYYY or jjjjjj^HL70005|5896 hyhyhyhy Ave^Apt# 112^Wanta Fe^NM^85678^XXX^H^^049||5033331120X ^PRN^PH^^^505^5551120^~^NET^X.400^[email protected]|5056083515X4365^WPN^PH^^^505^6086715^4365|es^English^HL70296||||215486702|||H^erererer or qwqwqw^HL70189|bnbnbn|Y|1|||| Thanks.

    Read the article

  • Edit exim4 Message-ID for releasing blocked mail by Mailscanner

    - by F12
    Our sysadmin team edits the field Message-ID in exim4 header files (ending with -H) and substitues the first char after "<". e.g: 077I Message-ID: <[email protected] -- 077I Message-ID: <[email protected] I'd like to write a script to release the mails. I changed the part between "<" and "@" in the field Message-ID and substituted a hash value so the Message-ID looks like: 077I Message-ID: <[email protected] Now exim says "format error" in the log and the mail is not released. There was no change except for this one field. Why can't the ID be substituted like that? Does it need to be the exact same length? It's exim4 version 4.69-2ubuntu0.3.

    Read the article

  • Is there a way to accumulate a commit message with git while examing changes?

    - by carleeto
    I use "git add -p" to stage my changes. What I'd like to be able to do is to accumulate a commit message as I'm examining my changes and then when I call "git commit", it is already filled out for me and allows me to make changes before I commit. Now, its easy to do with git gui by simply examining the changes and editing the commit message text box accordingly, but I'm a command line guy and was wondering if this is possible at the command line.

    Read the article

  • Do you think its user unfriendly to show error message in tooltips ?

    - by msfanboy
    Hello, when my user enters data validated as wrong a red circle with a white exclamation mark is shown in the right part of the textbox with the wrong data. The error message is only shown when the user hovers the textbox with wrong data. Do you think that is a bad User experience ? I could show the red error message text to the right side of the textboxes if there would still be space...

    Read the article

  • Message Passing Interface (MPI)

    So you have installed your cluster and you are done with introductory material on Windows HPC. Now you want to develop an application with the most common programming model: Message Passing Interface.The MPI programming model is a standard with implementations from many vendors. For newbies (like myself!), I have aggregated below links for getting started.Non-Microsoft MPI resources (useful even if you are not on the Windows platform)1. Message Passing Interface on wikipedia. 2. The MPI standard.3. MPICH2 - an MPI implementation.4. Tutorial on MPI by William Gropp.5. MPI patterns presented as a tutorial with sample code. 6. THE official MPI Forum (maintains the standard) including the wiki discussing the MPI future.7. Great MPI tutorial including at the end the MPI Exercise.8. C++ MPI Exercises by John Burkardt.9. Book online: MPI The Complete Reference.MS-MPI10. Windows HPC Server 2008 - Using MS-MPI whitepaper (15 page doc).11. Tracing MPI applications (27 page doc).12. Using Microsoft MPI (TechNet section).13. Windows HPC Server MPI forum (for posting questions). MPI.NET14. MPI.NET Home Page (not owned by Microsoft).15. MPI.NET Tutorial.16. HPC Development using F# using MPI.NET (38 page doc).Next time I'll post resources for the Microsoft Cluster SOA programming model - happy coding... Comments about this post welcome at the original blog.

    Read the article

  • JMS : Specifying Message Paging Directory on Weblogic server.

    - by adejuanc
    Two ways to configure or modify Paging directory, here the examples : 1.- Via config.xml file. <paging-directory>C:\temp</paging-directory> <jms-server> <name>JMSServerMS1</name> <target>MS1</target> <persistent-store xsi:nil="true"></persistent-store> <hosting-temporary-destinations>true</hosting-temporary-destinations> <temporary-template-resource xsi:nil="true"></temporary-template-resource> <temporary-template-name xsi:nil="true"></temporary-template-name> <message-buffer-size>-1</message-buffer-size> <paging-directory>C:\temp</paging-directory> <paging-file-locking-enabled>true</paging-file-locking-enabled> <expiration-scan-interval>30</expiration-scan-interval> </jms-server> ------------------------------------------------------- 2 .- Via WLST (Weblogic scripting tool) startEdit() cd('/Deployments/JMSServerMS1') cmo.setPagingDirectory('C:\\temp') activate()

    Read the article

  • Ubuntu 12.04 LTS: Error message "Failed to execute child process"

    - by Ron
    I am an Ubuntu-newbie and just started working with Ubuntu (version 12.04 LTS) a couple of days ago. I wanted to add a launcher icon to desktop for launching an application I previously installed. Up to now I can only launch it by typing setsid matlab -desktop into my terminal. Now there is the following problem with the execution via the desktop icon: Whenever I click the desktop icon, I get the following error message: "Failed to execute child process" I would like to add a screenshot, but unfortunately as a new user, I am not allowed to... In the main menu from where I added the icon via drag'n'drop to desktop there is also a permission to execute the .desktop file. I also tried to look for advice on the error message "Failed to execute child process..." but could not find anything useful. Now does anybody have an idea what I am missing? Sorry if this is a stupid question ;) ...but as I just said: I just started with Ubuntu... Thanks to everybody in advance for their help! :) And let me know if you should need any more information... Regards, Ron

    Read the article

  • Undeliverable e-mail message from [email protected]

    - by QGfisher
    I am responsible for IT for a small charity and we have a problem with a few individuals who e-mail us on our hosted e-mail addresses. The individual is on btconnect and our server is also on BT broadband and using MSExchange. I understand that the message from [email protected] are generated by Exchange but can't tell whether this is a problem with our server (seems unlikely as most people send and receive e-mails perfectly well) or with the sender's server. I have copied a sample test message below and would be very grateful if somebody can explain what is causing this problem. I have * the personal details - hope that's acceptable but I don't want to compromise the individual's identity/security. ----- Original Message ----- From: "System Administrator" To: "****" <****.***@btconnect.com Sent: Tuesday, April 06, 2010 3:26 PM Subject: Undeliverable: Test Message Your message To: ***** Subject: Test Message Sent: Tue, 6 Apr 2010 15:25:59 +0100 did not reach the following recipient(s): ***@quiltersguild.org.uk on Tue, 6 Apr 2010 15:26:07 +0100 The e-mail account does not exist at the organization this message was sent to. Check the e-mail address, or contact the recipient directly to find out the correct address.

    Read the article

  • How to retrive message list from p2p

    - by cre-johnny07
    Hello friends I have a messaging system that uses p2p. Each peer has a incoming message list and a outgoing message list. What I need to do is whenever a new peer will join the mesh he will get the all the incoming messages from other peers and add those into it's own incoming message list. Now I know when I get the other peer info from I can ask them to give their own list to me. But I'm not finding the way how..? Any suggestion on this or help would be highly appreciated. I'm giving my code below. Thanking in Advance Johnny #region Instance Fields private string strOrigin = ""; //the chat member name private string m_Member; //the channel instance where we execute our service methods against private IServerChannel m_participant; //the instance context which in this case is our window since it is the service host private InstanceContext m_site; //our binding transport for the p2p mesh private NetPeerTcpBinding m_binding; //the factory to create our chat channel private ChannelFactory<IServerChannel> m_channelFactory; //an interface provided by the channel exposing events to indicate //when we have connected or disconnected from the mesh private IOnlineStatus o_statusHandler; //a generic delegate to execute a thread against that accepts no args private delegate void NoArgDelegate(); //an object to hold user details private IUserService userService; //an Observable Collection of object to get all the Application Instance Details in databas ObservableCollection<AppLoginInstance> appLoginInstances; // an Observable Collection of object to get all Incoming Messages types ObservableCollection<MessageType> inComingMessageTypes; // an Observable Collection of object to get all Outgoing Messages ObservableCollection<PDCL.ERP.DataModels.Message> outGoingMessages; // an Observable Collection of object to get all Incoming Messages ObservableCollection<PDCL.ERP.DataModels.Message> inComingMessages; //an Event Aggregator to publish event for other modules to subscribe private readonly IEventAggregator eventAggregator; /// <summary> /// an IUnityCOntainer to get the container /// </summary> private IUnityContainer container; private RefreshConnectionStatus refreshConnectionStatus; private RefreshConnectionStatusEventArgs args; private ReplyRequestMessage replyMessageRequest; private ReplyRequestMessageEventArgs eventsArgs; #endregion public P2pMessageService(IUserService UserService, IEventAggregator EventAggregator, IUnityContainer container) { userService = UserService; this.container = container; appLoginInstances = new ObservableCollection<AppLoginInstance>(); inComingMessageTypes = new ObservableCollection<MessageType>(); inComingMessages = new ObservableCollection<PDCL.ERP.DataModels.Message>(); outGoingMessages = new ObservableCollection<PDCL.ERP.DataModels.Message>(); this.args = new RefreshConnectionStatusEventArgs(); this.eventsArgs = new ReplyRequestMessageEventArgs(); this.eventAggregator = EventAggregator; this.refreshConnectionStatus = this.eventAggregator.GetEvent<RefreshConnectionStatus>(); this.replyMessageRequest = this.eventAggregator.GetEvent<ReplyRequestMessage>(); } #region IOnlineStatus Event Handlers void ostat_Offline(object sender, EventArgs e) { // we could update a status bar or animate an icon to //indicate to the user they have disconnected from the mesh //currently i don't have a "disconnect" button but adding it //should be trivial if you understand the rest of this code } void ostat_Online(object sender, EventArgs e) { try { m_participant.Join(userService.AppInstance); } catch (Exception Ex) { Logger.Exception(Ex, Ex.TargetSite.Name + ": " + Ex.TargetSite + ": " + Ex.Message); } } #endregion #region IServer Members //this method gets called from a background thread to //connect the service client to the p2p mesh specified //by the binding info in the app.config public void ConnectToMesh() { try { m_site = new InstanceContext(this); //use the binding from the app.config with default settings m_binding = new NetPeerTcpBinding("P2PMessageBinding"); m_channelFactory = new DuplexChannelFactory<IServerChannel>(m_site, "P2PMessageEndPoint"); m_participant = m_channelFactory.CreateChannel(); o_statusHandler = m_participant.GetProperty<IOnlineStatus>(); o_statusHandler.Online += new EventHandler(ostat_Online); o_statusHandler.Offline += new EventHandler(ostat_Offline); //m_participant.InitializeMesh(); //this.appLoginInstances.Add(this.userService.AppInstance); BackgroundWorkerHelper.DoWork<object>(() => { //this is an empty unhandled method on the service interface. //why? because for some reason p2p clients don't try to connect to the mesh //until the first service method call. so to facilitate connecting i call this method //to get the ball rolling. m_participant.InitializeMesh(); //SynchronizeMessage(this.inComingMessages); return new object(); }, arg => { }); this.appLoginInstances.Add(this.userService.AppInstance); } catch (Exception Ex) { Logger.Exception(Ex, Ex.TargetSite.Name + ": " + Ex.TargetSite + ": " + Ex.Message); } } public void Join(AppLoginInstance obj) { try { // Adding Instance to the PeerList if (appLoginInstances.SingleOrDefault(a => a.InstanceId == obj.InstanceId)==null) { appLoginInstances.Add(obj); this.refreshConnectionStatus.Publish(new RefreshConnectionStatusEventArgs() { Status = m_channelFactory.State }); } //this will retrieve any new members that have joined before the current user m_participant.SynchronizeMemberList(userService.AppInstance); } catch(Exception Ex) { Logger.Exception(Ex,Ex.TargetSite.Name + ": " + Ex.TargetSite + ": " + Ex.Message); } } /// <summary> /// Synchronizes member list /// </summary> /// <param name="obj">The AppLoginInstance Param</param> public void SynchronizeMemberList(AppLoginInstance obj) { //as member names come in we simply disregard duplicates and //add them to the member list, this way we can retrieve a list //of members already in the chatroom when we enter at any time. //again, since this is just an example this is the simplified //way to do things. the correct way would be to retrieve a list //of peernames and retrieve the metadata from each one which would //tell us what the member name is and add it. we would want to check //this list when we join the mesh to make sure our member name doesn't //conflict with someone else try { if (appLoginInstances.SingleOrDefault(a => a.InstanceId == obj.InstanceId) == null) { appLoginInstances.Add(obj); } } catch (Exception Ex) { Logger.Exception(Ex, Ex.TargetSite.Name + ": " + Ex.TargetSite + ": " + Ex.Message); } } /// <summary> /// This methos broadcasts the mesasge to all peers. /// </summary> /// <param name="msg">The whole message which is to be broadcasted</param> /// <param name="securityLevels"> Level of security</param> public void BroadCastMsg(PDCL.ERP.DataModels.Message msg, List<string> securityLevels) { try { foreach (string s in securityLevels) { if (this.userService.IsInRole(s)) { if (this.inComingMessages.Count == 0 && msg.CreatedByApp != this.userService.AppInstanceId) { this.inComingMessages.Add(msg); } else if (this.inComingMessages.SingleOrDefault(a => a.MessageId == msg.MessageId) == null && msg.CreatedByApp != this.userService.AppInstanceId) { this.inComingMessages.Add(msg); } } } } catch (Exception Ex) { Logger.Exception(Ex, Ex.TargetSite.Name + ": " + Ex.TargetSite + ": " + Ex.Message); } } /// <summary> /// /// </summary> /// <param name="msg">The Message to denyed</param> public void BroadCastReplyMsg(PDCL.ERP.DataModels.Message msg) { try { //if (this.inComingMessages.SingleOrDefault(a => a.MessageId == msg.MessageId) != null) //{ this.replyMessageRequest.Publish(new ReplyRequestMessageEventArgs() { Message = msg }); this.inComingMessages.Remove(this.inComingMessages.SingleOrDefault(o => o.MessageId == msg.MessageId)); //} } catch (Exception ex) { Logger.Exception(ex, ex.TargetSite.Name + ": " + ex.TargetSite + ": " + ex.Message); } } //again we need to sync the worker thread with the UI thread via Dispatcher public void Whisper(string Member, string MemberTo, string Message) { } public void InitializeMesh() { //do nothing } public void Leave(AppLoginInstance obj) { if (this.appLoginInstances.SingleOrDefault(a => a.InstanceId == obj.InstanceId) != null) { this.appLoginInstances.Remove(this.appLoginInstances.Single(a => a.InstanceId == obj.InstanceId)); } } //public void SynchronizeRemoveMemberList(AppLoginInstance obj) //{ // if (appLoginInstances.SingleOrDefault(a => a.InstanceId == obj.InstanceId) != null) // { // appLoginInstances.Remove(obj); // } //} #endregion

    Read the article

  • How do I browse a Websphere MQ message without removing it?

    - by jmgant
    I'm writing a .NET Windows Forms application that will post a message to a Websphere MQ queue and then poll a different queue for a response. If a response is returned, the application will partially process the response in real time. But the response needs to stay in the queue so that a daily batch job, which also reads from the response queue, can do the rest of the processing. I've gotten as far as reading the message. What I haven't been able to figure out is how to read it without removing it. Here's what I've got so far. I'm an MQ newbie, so any suggestions will be appreciated. And feel free to respond in C#. Public Function GetMessage(ByVal msgID As String) As MQMessage Dim q = ConnectToResponseQueue() Dim msg As New MQMessage() Dim getOpts As New MQGetMessageOptions() Dim runThru = Now.AddMilliseconds(CInt(ConfigurationManager.AppSettings("responseTimeoutMS"))) System.Threading.Thread.Sleep(1000) 'Wait for one second before checking for the first response' While True Try q.Get(msg, getOpts) Return msg Catch ex As MQException When ex.Reason = MQC.MQRC_NO_MSG_AVAILABLE If Now > runThru Then Throw ex System.Threading.Thread.Sleep(3000) Finally q.Close() End Try End While Return Nothing 'Should never reach here' End Function NOTE: I haven't verified that my code actually removes the message. But that's how I understand MQ to work, and that appears to be what's happening. Please correct me if that's not the default behavior.

    Read the article

  • Debug.Assert-s use the same error message. Should I promote it to a static variable?

    - by Hamish Grubijan
    I love Asserts and code readability but not code duplication, and in several places I use a Debug.Assert which checks for the same condition like so: Debug.Assert(kosherBaconList.SelectedIndex != -1, "An error message along the lines - you should not ever be able to click on edit button without selecting a kosher bacon first."); This is in response to an actual bug, although the actual list does not contain kosher bacon. Anyhow, I can think of two approaches: private static readonly mustSelectKosherBaconBeforeEditAssertMessage = "An error message along the lines - you should not ever be able to " + "click on edit button without selecting a something first."; ... Debug.Assert( kosherBaconList.SelectedIndex != -1, mustSelectKosherBaconBeforeEditAssertMessage) or: if (kosherBaconList.SelectedIndex == -1) { AssertMustSelectKosherBaconBeforeEdit(); } ... [Conditional("DEBUG")] private void AssertMustSelectKosherBaconBeforeEdit() { // Compiler will optimize away this variable. string errorMessage = "An error message along the lines - you should not ever be able to " + "click on edit button without selecting a something first."; Debug.Assert(false, errorMessage); } or is there a third way which sucks less than either one above? Please share. General helpful relevant tips are also welcome.

    Read the article

  • Want to Receive dynamic length data from a message queue in IPC?

    - by user1089679
    Here I have to send and receive dynamic data using a SysV message queue. so in structure filed i have dynamic memory allocation char * because its size may be varies. so how can i receive this type of message at receiver side. Please let me know how can i send dynamic length of data with message queue. I am getting problem in this i posted my code below. send.c /*filename : send.c *To compile : gcc send.c -o send */ #include <stdio.h> #include <stdlib.h> #include <errno.h> #include <string.h> #include <sys/types.h> #include <sys/ipc.h> #include <sys/msg.h> struct my_msgbuf { long mtype; char *mtext; }; int main(void) { struct my_msgbuf buf; int msqid; key_t key; static int count = 0; char temp[5]; int run = 1; if ((key = ftok("send.c", 'B')) == -1) { perror("ftok"); exit(1); } printf("send.c Key is = %d\n",key); if ((msqid = msgget(key, 0644 | IPC_CREAT)) == -1) { perror("msgget"); exit(1); } printf("Enter lines of text, ^D to quit:\n"); buf.mtype = 1; /* we don't really care in this case */ int ret = -1; while(run) { count++; buf.mtext = malloc(50); strcpy(buf.mtext,"Hi hello test message here"); snprintf(temp, sizeof (temp), "%d",count); strcat(buf.mtext,temp); int len = strlen(buf.mtext); /* ditch newline at end, if it exists */ if (buf.mtext[len-1] == '\n') buf.mtext[len-1] = '\0'; if (msgsnd(msqid, &buf, len+1, IPC_NOWAIT) == -1) /* +1 for '\0' */ perror("msgsnd"); if(count == 100) run = 0; usleep(1000000); } if (msgctl(msqid, IPC_RMID, NULL) == -1) { perror("msgctl"); exit(1); } return 0; } receive.c /* filename : receive.c * To compile : gcc receive.c -o receive */ #include <stdio.h> #include <stdlib.h> #include <errno.h> #include <sys/types.h> #include <sys/ipc.h> #include <sys/msg.h> struct my_msgbuf { long mtype; char *mtext; }; int main(void) { struct my_msgbuf buf; int msqid; key_t key; if ((key = ftok("send.c", 'B')) == -1) { /* same key as send.c */ perror("ftok"); exit(1); } if ((msqid = msgget(key, 0644)) == -1) { /* connect to the queue */ perror("msgget"); exit(1); } printf("test: ready to receive messages, captain.\n"); for(;;) { /* receive never quits! */ buf.mtext = malloc(50); if (msgrcv(msqid, &buf, 50, 0, 0) == -1) { perror("msgrcv"); exit(1); } printf("test: \"%s\"\n", buf.mtext); } return 0; }

    Read the article

  • JMS Step 4 - How to Create an 11g BPEL Process Which Writes a Message Based on an XML Schema to a JMS Queue

    - by John-Brown.Evans
    JMS Step 4 - How to Create an 11g BPEL Process Which Writes a Message Based on an XML Schema to a JMS Queue ol{margin:0;padding:0} .c11_4{vertical-align:top;width:129.8pt;border-style:solid;background-color:#f3f3f3;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c9_4{vertical-align:top;width:207pt;border-style:solid;background-color:#f3f3f3;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt}.c14{vertical-align:top;width:207pt;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c17_4{vertical-align:top;width:129.8pt;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c7_4{vertical-align:top;width:130pt;border-style:solid;border-color:#000000;border-width:1pt;padding:0pt 5pt 0pt 5pt} .c19_4{vertical-align:top;width:468pt;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c22_4{background-color:#ffffff} .c20_4{list-style-type:disc;margin:0;padding:0} .c6_4{font-size:8pt;font-family:"Courier New"} .c24_4{color:inherit;text-decoration:inherit} .c23_4{color:#1155cc;text-decoration:underline} .c0_4{height:11pt;direction:ltr} .c10_4{font-size:10pt;font-family:"Courier New"} .c3_4{padding-left:0pt;margin-left:36pt} .c18_4{font-size:8pt} .c8_4{text-align:center} .c12_4{background-color:#ffff00} .c2_4{font-weight:bold} .c21_4{background-color:#00ff00} .c4_4{line-height:1.0} .c1_4{direction:ltr} .c15_4{background-color:#f3f3f3} .c13_4{font-family:"Courier New"} .c5_4{font-style:italic} .c16_4{border-collapse:collapse} .title{padding-top:24pt;line-height:1.15;text-align:left;color:#000000;font-size:36pt;font-family:"Arial";font-weight:bold;padding-bottom:6pt} .subtitle{padding-top:18pt;line-height:1.15;text-align:left;color:#666666;font-style:italic;font-size:24pt;font-family:"Georgia";padding-bottom:4pt} li{color:#000000;font-size:10pt;font-family:"Arial"} p{color:#000000;font-size:10pt;margin:0;font-family:"Arial"} h1{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:18pt;font-family:"Arial";font-weight:normal;padding-bottom:0pt} h2{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:18pt;font-family:"Arial";font-weight:bold;padding-bottom:0pt} h3{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:14pt;font-family:"Arial";font-weight:normal;padding-bottom:0pt} h4{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-style:italic;font-size:11pt;font-family:"Arial";padding-bottom:0pt} h5{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:10pt;font-family:"Arial";font-weight:normal;padding-bottom:0pt} h6{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-style:italic;font-size:10pt;font-family:"Arial";padding-bottom:0pt} This post continues the series of JMS articles which demonstrate how to use JMS queues in a SOA context. The previous posts were: JMS Step 1 - How to Create a Simple JMS Queue in Weblogic Server 11g JMS Step 2 - Using the QueueSend.java Sample Program to Send a Message to a JMS Queue JMS Step 3 - Using the QueueReceive.java Sample Program to Read a Message from a JMS Queue In this example we will create a BPEL process which will write (enqueue) a message to a JMS queue using a JMS adapter. The JMS adapter will enqueue the full XML payload to the queue. This sample will use the following WebLogic Server objects. The first two, the Connection Factory and JMS Queue, were created as part of the first blog post in this series, JMS Step 1 - How to Create a Simple JMS Queue in Weblogic Server 11g. If you haven't created those objects yet, please see that post for details on how to do so. The Connection Pool will be created as part of this example. Object Name Type JNDI Name TestConnectionFactory Connection Factory jms/TestConnectionFactory TestJMSQueue JMS Queue jms/TestJMSQueue eis/wls/TestQueue Connection Pool eis/wls/TestQueue 1. Verify Connection Factory and JMS Queue As mentioned above, this example uses a WLS Connection Factory called TestConnectionFactory and a JMS queue TestJMSQueue. As these are prerequisites for this example, let us verify they exist. Log in to the WebLogic Server Administration Console. Select Services > JMS Modules > TestJMSModule You should see the following objects: If not, or if the TestJMSModule is missing, please see the abovementioned article and create these objects before continuing. 2. Create a JMS Adapter Connection Pool in WebLogic Server The BPEL process we are about to create uses a JMS adapter to write to the JMS queue. The JMS adapter is deployed to the WebLogic server and needs to be configured to include a connection pool which references the connection factory associated with the JMS queue. In the WebLogic Server Console Go to Deployments > Next and select (click on) the JmsAdapter Select Configuration > Outbound Connection Pools and expand oracle.tip.adapter.jms.IJmsConnectionFactory. This will display the list of connections configured for this adapter. For example, eis/aqjms/Queue, eis/aqjms/Topic etc. These JNDI names are actually quite confusing. We are expecting to configure a connection pool here, but the names refer to queues and topics. One would expect these to be called *ConnectionPool or *_CF or similar, but to conform to this nomenclature, we will call our entry eis/wls/TestQueue . This JNDI name is also the name we will use later, when creating a BPEL process to access this JMS queue! Select New, check the oracle.tip.adapter.jms.IJmsConnectionFactory check box and Next. Enter JNDI Name: eis/wls/TestQueue for the connection instance, then press Finish. Expand oracle.tip.adapter.jms.IJmsConnectionFactory again and select (click on) eis/wls/TestQueue The ConnectionFactoryLocation must point to the JNDI name of the connection factory associated with the JMS queue you will be writing to. In our example, this is the connection factory called TestConnectionFactory, with the JNDI name jms/TestConnectionFactory.( As a reminder, this connection factory is contained in the JMS Module called TestJMSModule, under Services > Messaging > JMS Modules > TestJMSModule which we verified at the beginning of this document. )Enter jms/TestConnectionFactory  into the Property Value field for Connection Factory Location. After entering it, you must press Return/Enter then Save for the value to be accepted. If your WebLogic server is running in Development mode, you should see the message that the changes have been activated and the deployment plan successfully updated. If not, then you will manually need to activate the changes in the WebLogic server console. Although the changes have been activated, the JmsAdapter needs to be redeployed in order for the changes to become effective. This should be confirmed by the message Remember to update your deployment to reflect the new plan when you are finished with your changes as can be seen in the following screen shot: The next step is to redeploy the JmsAdapter.Navigate back to the Deployments screen, either by selecting it in the left-hand navigation tree or by selecting the “Summary of Deployments” link in the breadcrumbs list at the top of the screen. Then select the checkbox next to JmsAdapter and press the Update button On the Update Application Assistant page, select “Redeploy this application using the following deployment files” and press Finish. After a few seconds you should get the message that the selected deployments were updated. The JMS adapter configuration is complete and it can now be used to access the JMS queue. To summarize: we have created a JMS adapter connection pool connector with the JNDI name jms/TestConnectionFactory. This is the JNDI name to be accessed by a process such as a BPEL process, when using the JMS adapter to access the previously created JMS queue with the JNDI name jms/TestJMSQueue. In the following step, we will set up a BPEL process to use this JMS adapter to write to the JMS queue. 3. Create a BPEL Composite with a JMS Adapter Partner Link This step requires that you have a valid Application Server Connection defined in JDeveloper, pointing to the application server on which you created the JMS Queue and Connection Factory. You can create this connection in JDeveloper under the Application Server Navigator. Give it any name and be sure to test the connection before completing it. This sample will use the connection name jbevans-lx-PS5, as that is the name of the connection pointing to my SOA PS5 installation. When using a JMS adapter from within a BPEL process, there are various configuration options, such as the operation type (consume message, produce message etc.), delivery mode and message type. One of these options is the choice of the format of the JMS message payload. This can be structured around an existing XSD, in which case the full XML element and tags are passed, or it can be opaque, meaning that the payload is sent as-is to the JMS adapter. In the case of an XSD-based message, the payload can simply be copied to the input variable of the JMS adapter. In the case of an opaque message, the JMS adapter’s input variable is of type base64binary. So the payload needs to be converted to base64 binary first. I will go into this in more detail in a later blog entry. This sample will pass a simple message to the adapter, based on the following simple XSD file, which consists of a single string element: stringPayload.xsd <?xml version="1.0" encoding="windows-1252" ?> <xsd:schema xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns="http://www.example.org" targetNamespace="http://www.example.org" elementFormDefault="qualified" <xsd:element name="exampleElement" type="xsd:string"> </xsd:element> </xsd:schema> The following steps are all executed in JDeveloper. The SOA project will be created inside a JDeveloper Application. If you do not already have an application to contain the project, you can create a new one via File > New > General > Generic Application. Give the application any name, for example JMSTests and, when prompted for a project name and type, call the project JmsAdapterWriteWithXsd and select SOA as the project technology type. If you already have an application, continue below. Create a SOA Project Create a new project and choose SOA Tier > SOA Project as its type. Name it JmsAdapterWriteSchema. When prompted for the composite type, choose Composite With BPEL Process. When prompted for the BPEL Process, name it JmsAdapterWriteSchema too and choose Synchronous BPEL Process as the template. This will create a composite with a BPEL process and an exposed SOAP service. Double-click the BPEL process to open and begin editing it. You should see a simple BPEL process with a Receive and Reply activity. As we created a default process without an XML schema, the input and output variables are simple strings. Create an XSD File An XSD file is required later to define the message format to be passed to the JMS adapter. In this step, we create a simple XSD file, containing a string variable and add it to the project. First select the xsd item in the left-hand navigation tree to ensure that the XSD file is created under that item. Select File > New > General > XML and choose XML Schema. Call it stringPayload.xsd and when the editor opens, select the Source view. then replace the contents with the contents of the stringPayload.xsd example above and save the file. You should see it under the xsd item in the navigation tree. Create a JMS Adapter Partner Link We will create the JMS adapter as a service at the composite level. If it is not already open, double-click the composite.xml file in the navigator to open it. From the Component Palette, drag a JMS adapter over onto the right-hand swim lane, under External References. This will start the JMS Adapter Configuration Wizard. Use the following entries: Service Name: JmsAdapterWrite Oracle Enterprise Messaging Service (OEMS): Oracle Weblogic JMS AppServer Connection: Use an existing application server connection pointing to the WebLogic server on which the above JMS queue and connection factory were created. You can use the “+” button to create a connection directly from the wizard, if you do not already have one. This example uses a connection called jbevans-lx-PS5. Adapter Interface > Interface: Define from operation and schema (specified later) Operation Type: Produce Message Operation Name: Produce_message Destination Name: Press the Browse button, select Destination Type: Queues, then press Search. Wait for the list to populate, then select the entry for TestJMSQueue , which is the queue created earlier. JNDI Name: The JNDI name to use for the JMS connection. This is probably the most important step in this exercise and the most common source of error. This is the JNDI name of the JMS adapter’s connection pool created in the WebLogic Server and which points to the connection factory. JDeveloper does not verify the value entered here. If you enter a wrong value, the JMS adapter won’t find the queue and you will get an error message at runtime, which is very difficult to trace. In our example, this is the value eis/wls/TestQueue . (See the earlier step on how to create a JMS Adapter Connection Pool in WebLogic Server for details.) MessagesURL: We will use the XSD file we created earlier, stringPayload.xsd to define the message format for the JMS adapter. Press the magnifying glass icon to search for schema files. Expand Project Schema Files > stringPayload.xsd and select exampleElement: string. Press Next and Finish, which will complete the JMS Adapter configuration. Wire the BPEL Component to the JMS Adapter In this step, we link the BPEL process/component to the JMS adapter. From the composite.xml editor, drag the right-arrow icon from the BPEL process to the JMS adapter’s in-arrow. This completes the steps at the composite level. 4. Complete the BPEL Process Design Invoke the JMS Adapter Open the BPEL component by double-clicking it in the design view of the composite.xml, or open it from the project navigator by selecting the JmsAdapterWriteSchema.bpel file. This will display the BPEL process in the design view. You should see the JmsAdapterWrite partner link under one of the two swim lanes. We want it in the right-hand swim lane. If JDeveloper displays it in the left-hand lane, right-click it and choose Display > Move To Opposite Swim Lane. An Invoke activity is required in order to invoke the JMS adapter. Drag an Invoke activity between the Receive and Reply activities. Drag the right-hand arrow from the Invoke activity to the JMS adapter partner link. This will open the Invoke editor. The correct default values are entered automatically and are fine for our purposes. We only need to define the input variable to use for the JMS adapter. By pressing the green “+” symbol, a variable of the correct type can be auto-generated, for example with the name Invoke1_Produce_Message_InputVariable. Press OK after creating the variable. ( For some reason, while I was testing this, the JMS Adapter moved back to the left-hand swim lane again after this step. There is no harm in leaving it there, but I find it easier to follow if it is in the right-hand lane, because I kind-of think of the message coming in on the left and being routed through the right. But you can follow your personal preference here.) Assign Variables Drag an Assign activity between the Receive and Invoke activities. We will simply copy the input variable to the JMS adapter and, for completion, so the process has an output to print, again to the process’s output variable. Double-click the Assign activity and create two Copy rules: for the first, drag Variables > inputVariable > payload > client:process > client:input_string to Invoke1_Produce_Message_InputVariable > body > ns2:exampleElement for the second, drag the same input variable to outputVariable > payload > client:processResponse > client:result This will create two copy rules, similar to the following: Press OK. This completes the BPEL and Composite design. 5. Compile and Deploy the Composite We won’t go into too much detail on how to compile and deploy. In JDeveloper, compile the process by pressing the Make or Rebuild icons or by right-clicking the project name in the navigator and selecting Make... or Rebuild... If the compilation is successful, deploy it to the SOA server connection defined earlier. (Right-click the project name in the navigator, select Deploy to Application Server, choose the application server connection, choose the partition on the server (usually default) and press Finish. You should see the message ---- Deployment finished. ---- in the Deployment frame, if the deployment was successful. 6. Test the Composite This is the exciting part. Open two tabs in your browser and log in to the WebLogic Administration Console in one tab and the Enterprise Manager 11g Fusion Middleware Control (EM) for your SOA installation in the other. We will use the Console to monitor the messages being written to the queue and the EM to execute the composite. In the Console, go to Services > Messaging > JMS Modules > TestJMSModule > TestJMSQueue > Monitoring. Note the number of messages under Messages Current. In the EM, go to SOA > soa-infra (soa_server1) > default (or wherever you deployed your composite to) and click on JmsAdapterWriteSchema [1.0], then press the Test button. Under Input Arguments, enter any string into the text input field for the payload, for example Test Message then press Test Web Service. If the instance is successful you should see the same text in the Response message, “Test Message”. In the Console, refresh the Monitoring screen to confirm a new message has been written to the queue. Check the checkbox and press Show Messages. Click on the newest message and view its contents. They should include the full XML of the entered payload. 7. Troubleshooting If you get an exception similar to the following at runtime ... BINDING.JCA-12510 JCA Resource Adapter location error. Unable to locate the JCA Resource Adapter via .jca binding file element The JCA Binding Component is unable to startup the Resource Adapter specified in the element: location='eis/wls/QueueTest'. The reason for this is most likely that either 1) the Resource Adapters RAR file has not been deployed successfully to the WebLogic Application server or 2) the '' element in weblogic-ra.xml has not been set to eis/wls/QueueTest. In the last case you will have to add a new WebLogic JCA connection factory (deploy a RAR). Please correct this and then restart the Application Server at oracle.integration.platform.blocks.adapter.fw.AdapterBindingException. createJndiLookupException(AdapterBindingException.java:130) at oracle.integration.platform.blocks.adapter.fw.jca.cci. JCAConnectionManager$JCAConnectionPool.createJCAConnectionFactory (JCAConnectionManager.java:1387) at oracle.integration.platform.blocks.adapter.fw.jca.cci. JCAConnectionManager$JCAConnectionPool.newPoolObject (JCAConnectionManager.java:1285) ... then this is very likely due to an incorrect JNDI name entered for the JMS Connection in the JMS Adapter Wizard. Recheck those steps. The error message prints the name of the JNDI name used. In this example, it was incorrectly entered as eis/wls/QueueTest instead of eis/wls/TestQueue. This concludes this example. Best regards John-Brown Evans Oracle Technology Proactive Support Delivery

    Read the article

  • When do I use Apache Kafka, Azure Service Bus, vs Azure Queues?

    - by makerofthings7
    I'm trying to understand the situations I'd use Apache Kafka, Azure Service Bus, or Azure Queues for high scale message processing. Which is better for standard Pub Sub situations? Where multiple clients get a copy of the same message? Which is better for low latency Pub sub and no durability? Which is better for "cooperating producer" and "competing consumer"? (what does this mean?) I see a bit of overlap in function between Kafka, Service Bus, Azure Queues

    Read the article

  • sftp Bad message - (badly formatted packet or protocol incompatibility)

    - by culter
    I have two servers connected through SFTP. When I'm trying to upload file DONATE_SPLATNOSTSFRB-1503_20120315.xls.gpg via WinSCP, it works fine, but when I change file name to DONATE_SPLATNOSTSFRB-1503_20120315.gpg it sometimes upload to server and sometimes not. When It's uploaded, I have problems to delete it. I get this error message: Bad message - (badly formatted packet or protocol incompatibility) Error code: 5 Error message from server: Bad Message Request code: 13 Others files works fine e.g.: DONATE_PREDSFRB-0212_20120315.gpg Thank you.

    Read the article

< Previous Page | 4 5 6 7 8 9 10 11 12 13 14 15  | Next Page >