  • How to add NT Virtual Machine\Virtual Machines to GPO

    - by Nicola Cassolato
    I have a Windows 2012 Server with Hyper-V enabled and a few virtual machines. My current configuration has a few account in the "Log on as a service" list in the domain policies, and sometimes this prevent my virtual machines from starting (I get this error: 'Error 0x80070569 ('VM_NAME' failed to start worker process: Logon Failure: The user has not been granted the requested logon type at this computer.') As described in this KB I would like to add NT Virtual Machine\Virtual Machines to my "Log on as a service" list to resolve my problem. My problem is that when I try to add that user to my domain policy I get an error message: "The following account could not be validated". My domain controller obviously doesn't know about that user since it's not an Hyper-V enabled server. How can I add that account to my Domain Policies?

    Read the article

  • Cannot set ILMerge path to console

    - by KMC
    I install ILMerge.exe; path is C:\Program Files\Microsoft\ILMerge\ILMerge.exe. I want to set the command to the Path so I can type ilmerge anywhere to use the application. I googled and tried all the following but none works: setx -m ilmerge;C:\Program Files\Microsoft\ILMerge\ILMerge.exe setx -M ilmerge;C:\Program Files\Microsoft\ILMerge\ILMerge.exe setx -m %PATH%;C:\Program Files\Microsoft\ILMerge\ILMerge.exe setx /S system /U administrator ilmerge;C:\Program Files\Microsoft\ILMerge\ILMerge.exe I then tried to add, the GUI's Environment Variables, click New and input the variable "ilmerge" and value "C:\Program Files\Microsoft\ILMerge\ILMerge.exe". But in command prompt and type in ilmerge, still gives me 'ilmerge' is not recognized as an internal or external command, operable program or bath file. Why something as basic as setting a path that confusing..

    Read the article

  • Disable usage of console-kit-daemon in Ubuntu

    - by Alex Marshall
    Hello, I administrate several Ubuntu 9.04 servers, and everytime I log in, I get the Landscape utility printout with server stats, etc. I really don't need this and it slows down my logins considerably. Can somebody please tell me how to disable message of the day as well as the landscape-sysin daemon ? I started tracking my logins using top, and when a user logs in, sshd shoots right up to 100% CPU usage, and I believe that landscape and the message of the day update daemon are the primary culprits. Does anybody else have any ideas as to what could be causing my horrible login times ?

    Read the article

  • Apache disabled virtual host domains resolve an enabled virtual host

    - by littleK
    I have three virtual hosts defined on apache on my Ubuntu server for three different domains. If I disable two of the virtual hosts (a2dissite) and try to resolve those two URL's in the browser, then the one remaining enabled site will resolve. How can I configure apache so that the domains for the disabled virtual hosts do not resolve? This is how all 3 virtual hosts are configured (info is masked): # domain: myfirstdomain.com # public: /home/me/public/myfirstdomain.com/ <VirtualHost *:80> # Admin email, Server Name (domain name), and any aliases ServerAdmin [email protected] ServerName www.myfirstdomain.com ServerAlias myfirstdomain.com # Index file and Document Root (where the public files are located) DirectoryIndex index.html index.php DocumentRoot /home/me/public/myfirstdomain.com/public # Log file locations LogLevel warn ErrorLog /home/me/public/myfirstdomain.com/log/error.log CustomLog /home/me/public/myfirstdomain.com/log/access.log combined </VirtualHost>

    Read the article

  • graphic error on console

    - by Christian Elsner
    I have Linux on an embedded system. There is no graphic system, but I still have graphic errors. For example, if I type: ifconfig eth2 hw ether 00:0e:8c:d0:59:d2 I see: ifconfig eth hw ether 00:0e:8:2:2 If I type Enter, it accepts the command I typed, so it's just a matter of displaying. Everything is fine, when I log in via SSH. Anyone any ideas, what could be the cause or where to look at? Output of lspci: 00:00.0 Host bridge: Intel Corporation 3100 Chipset Memory I/O Controller Hub 00:00.1 Unassigned class [ff00]: Intel Corporation 3100 DRAM Controller Error Reporting Registers 00:01.0 System peripheral: Intel Corporation 3100 Chipset Enhanced DMA Controller 00:02.0 PCI bridge: Intel Corporation 3100 Chipset PCI Express Port A 00:03.0 PCI bridge: Intel Corporation 3100 Chipset PCI Express Port A1 00:1c.0 PCI bridge: Intel Corporation 631xESB/632xESB/3100 Chipset PCI Express Root Port 1 (rev 01) 00:1c.1 PCI bridge: Intel Corporation 631xESB/632xESB/3100 Chipset PCI Express Root Port 2 (rev 01) 00:1d.0 USB Controller: Intel Corporation 631xESB/632xESB/3100 Chipset UHCI USB Controller #1 (rev 01) 00:1d.1 USB Controller: Intel Corporation 631xESB/632xESB/3100 Chipset UHCI USB Controller #2 (rev 01) 00:1d.7 USB Controller: Intel Corporation 631xESB/632xESB/3100 Chipset EHCI USB2 Controller (rev 01) 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev c9) 00:1f.0 ISA bridge: Intel Corporation 631xESB/632xESB/3100 Chipset LPC Interface Controller (rev 01) 00:1f.2 IDE interface: Intel Corporation 631xESB/632xESB/3100 Chipset SATA IDE Controller (rev 01) 00:1f.3 SMBus: Intel Corporation 631xESB/632xESB/3100 Chipset SMBus Controller (rev 01) 02:00.0 Ethernet controller: Intel Corporation 82574L Gigabit Network Connection 03:01.0 Network controller: Siemens Nixdorf AG Device 4003 (rev 02) 03:01.1 Unassigned class [ff00]: Siemens Nixdorf AG Device 4003 (rev 02) 03:02.0 Ethernet controller: Siemens Nixdorf AG Device 4047 (rev 01) 03:03.0 Ethernet controller: National Semiconductor Corporation DP83815 (MacPhyter) Ethernet Controller 03:04.0 Unassigned class [ff00]: Siemens Nixdorf AG Device 4057 (rev 01) 04:00.0 PCI bridge: Texas Instruments XIO2000(A)/XIO2200(A) PCI Express-to-PCI Bridge (rev 03) 05:00.0 Ethernet controller: Advanced Micro Devices [AMD] 79c970 [PCnet32 LANCE] (rev 44) 06:00.0 PCI bridge: Texas Instruments XIO2000(A)/XIO2200(A) PCI Express-to-PCI Bridge (rev 03) 07:00.0 VGA compatible controller: Silicon Motion, Inc. SM720 Lynx3DM (rev c1) 07:01.0 USB Controller: NEC Corporation USB (rev 43) 07:01.1 USB Controller: NEC Corporation USB (rev 43) 07:01.2 USB Controller: NEC Corporation USB 2.0 (rev 04) The whole thing is running on an Intel Core 2 Duo U2500

    Read the article

  • What are the Best Virtual Desktop Managers for Windows 7 excluding Dexpot? [closed]

    - by user233641
    My question is different to others as my list of important features is completely different and I believe unique. Necessary Features Are: Dual-monitor support 6 desktops minimum Different icons can be created on different desktops Reliable and does not delete or remove icons without input from me Ability to save profiles and reload them if necessary Ability to change the home desktop to a different one Reasonably easy to use Keyboard Support Good email support

    Read the article

  • Recent improvements in Console Performance

    - by loren.konkus
    Recently, the WebLogic Server development and support organizations have worked with a number of customers to quantify and improve the performance of the Administration Console in large, distributed configurations where there is significant latency in the communications between the administration server and managed servers. These improvements fall into two categories: Constraining the amount of time that the Console stalls waiting for communication Reducing and streamlining the amount of data required for an update A few releases ago, we added support for a configurable domain-wide mbean "Invocation Timeout" value on the Console's configuration: general, advanced section for a domain. The default value for this setting is 0, which means wait indefinitely and was chosen for compatibility with the behavior of previous releases. This configuration setting applies to all mbean communications between the admin server and managed servers, and is the first line of defense against being blocked by a stalled or completely overloaded managed server. Each site should choose an appropriate timeout value for their environment and network latency. In the next release of WebLogic Server, we've added an additional console preference, "Management Operation Timeout", to the Console's shared preference page. This setting further constrains how long certain console pages will wait for slowly responding servers before returning partial results. While not all Console pages support this yet, key pages such as the Servers Configuration and Control table pages and the Deployments Control pages have been updated to support this. For example, if a user requests a Servers Table page and a Management Operation Timeout occurs, the table is displayed with both local configuration and remote runtime information from the responding managed servers and only local configuration information for servers that did not yet respond. This means that a troublesome managed server does not impede your ability to manage your domain using the Console. To support these changes, these Console pages have been re-written to use the Work Management feature of WebLogic Server to interact with each server or deployment concurrently, which further improves the responsiveness of these pages. The basic algorithm for these pages is: For each configuration mbean (ie, Servers) populate rows with configuration attributes from the fast, local mbean server Find a WorkManager For each server, Create a Work instance to obtain runtime mbean attributes for the server Schedule Work instance in the WorkManager Call WorkManager.waitForAll to wait WorkItems to finish, constrained by Management Operation Timeout For each WorkItem, if the runtime information obtained was not complete, add a message indicating which server has incomplete data Display collected data in table In addition to these changes to constrain how long the console waits for communication, a number of other changes have been made to reduce the amount and scope of managed server interactions for key pages. For example, in previous releases the Deployments Control table looked at the status of a deployment on every managed server, even those servers that the deployment was not currently targeted on. (This was done to handle an edge case where a deployment's target configuration was changed while it remained running on previously targeted servers.) We decided supporting that edge case did not warrant the performance impact for all, and instead only look at the status of a deployment on the servers it is targeted to. Comprehensive status continues to be available if a user clicks on the 'status' field for a deployment. Finally, changes have been made to the System Status portlet to reduce its impact on Console page display times. Obtaining health information for this display requires several mbean interactions with managed servers. In previous releases, this mbean interaction occurred with every display, and any delay or impediment in these interactions was reflected in the display time for every page. To reduce this impact, we've made several changes in this portlet: Using Work Management to obtain health concurrently Applying the operation timeout configuration to constrain how long we will wait Caching health information to reduce the cost during rapid navigation from page to page and only obtaining new health information if the previous information is over 30 seconds old. Eliminating heath collection if this portlet is minimized. Together, these Console changes have resulted in significant performance improvements for the customers with large configurations and high latency that we have worked with during their development, and some lesser performance improvements for those with small configurations and very fast networks. These changes will be included in the 11g Rel 1 patch set 2 (10.3.3.0) release of WebLogic Server.

    Read the article

  • Forms authentication ignored in virtual application

    - by Christo Fur
    I have an admin site swet up as a virtual applcation inside of another website. I would like visitors to the sub directory (the virtual application) to be promtped for credentials using the same Forms autheentication set up on the main parent site Have tried all sorts of things but can't get it to work including Removing all ,, and sections from the virtual-app web.config Copying the same ,, and sections from the parent to the virtual-app web.config Using a virtual directory instead of virtual application But I never get promted for credentials Anyone know how to get this setup? thanks

    Read the article

  • Virtual CloneDrive - Free Utility

    - by TATWORTH
    At http://www.slysoft.com/en/virtual-clonedrive.html, SlySoft have made available, Virtual Clone Drive."Virtual CloneDrive works and behaves just like a physical CD/DVD drive, however it exists only virtually. Image files generated with CloneDVD or CloneCD can be mounted onto a virtual drive from your hard-disk or from a network drive and used in the same manner as inserting them into a normal CD/DVD drive. Probably the best virtual drive software, Virtual CloneDrive allows you to enjoy the freedom of a virtual drive and is completely free."

    Read the article

  • nunit-console.exe problem with Mono

    - by prosseek
    I could make a dll for NUnit (http://stackoverflow.com/questions/2967726/nunit-test-under-mono), but when I tried to run in with nunit-console.exe I get the following error message. Runtime Environment - OS Version: Unix 10.3.0.0 CLR Version: 2.0.50727.1433 ( 2.6.4 (tarball Thu Apr 22 13:24:33 MDT 2010) ) ProcessModel: Default DomainUsage: Single Execution Runtime: mono-2.0 ** (/Users/smcho/bin/NUnit-2.5.5.10112/bin/net-2.0/nunit-console.exe:36800): WARNING **: The following assembly referenced from /private/var/folders/m4/m4u1hmP+FHOQaiZbHj1UCk+++TI/-Tmp-/nunit20/ShadowCopyCache/36800_634111616836311880/Tests_-22323139/assembly/shadow/54274fc2/118e035c_45a94c9e_00000001/mut.dll could not be loaded: Assembly: nunit.framework (assemblyref_index=1) Version: 2.5.5.10112 Public Key: 96d09a1eb7f44a77 System error: Invalid argument ** (/Users/smcho/bin/NUnit-2.5.5.10112/bin/net-2.0/nunit-console.exe:36800): WARNING **: Could not load file or assembly 'nunit.framework, Version=2.5.5.10112, Culture=neutral, PublicKeyToken=96d09a1eb7f44a77' or one of its dependencies. What might be wrong? I have nunit.framework.dll under /Users/smcho/bin/NUnit-2.5.5.10112/bin/net-2.0/framework, but it doesn't seem to know about this.

    Read the article

  • Displaying images in a console application?!

    - by Stefan Kendall
    I have a console application which screen scrapes some data, and now I need to do image comparisons. If the images are different, I want to show the images to the user. What's the best way to display two images during the execution of a console application? I'm assuming I would use some sort of inter-process communication to send information back and forth, but I'm not sure how exactly I would go about doing that in a good fashion. Also, I'd rather NOT store the images to files if possible. There's no reason to persist the data, and if the console application terminates unexpectedly, it's better if I don't have any dirt left on the file system. Does anyone have any thoughts on how best to accomplish this?

    Read the article

  • How to correctly pop a modeless dialog from console using MFC

    - by Vertilka
    I need to create a console application that has a main() function and pop a modeless dialog, so the console can still work in parallel to the modeless dialog (do other work, like communicating with the modeless dialog). Whatever i tried, i could only pop a modal dialog. (where the console is in hold till the modal dialog close itself). When switching to modeless dialog using Create() and ShowWindow() the dialog is displayed without its controls and it freeze / block (you can see the hourglass cursor). 1) i tried to pop the modeless dialog from the main() function 2) i tried to pop the modeless dialog from the InitInstance() of a CWinApp derived class In all cases the modeless dialog freeze / block. I believe this is a one line solution. TNX,Vertilka

    Read the article

  • WindowsForms difference to simple Console App

    - by daemonfire300
    I currently started to "port" my console projects to WinForms, but it seems I am badly failing doing that. I am simply used to a console structure: I got my classes interacting with each other depending on the input coming from the console. A simple flow: Input -> ProcessInput -> Execute -> Output -> wait for input Now I got this big Form1.cs (etc.) and the "Application.Run(Form1);" But I really got no clue how my classes can interact with the form and create a flow like I described above. I mean, I just have these "...._Click(object sender....)" for each "item" inside the form. Now I do not know where to place / start my flow / loop, and how my classes can interact with the form.

    Read the article

  • C#, WindowsForms difference to simple Console App

    - by daemonfire300
    Hi there, I currently started to "port" my console projects to WinForms, but it seems I am badly failing doing that. I am simply used to a console structure: I got my classes interacting with each other depending on the input coming from the console. A simple flow: Input -> ProcessInput -> Execute -> Output -> wait for input Now I got this big Form1.cs (etc.) and the "Application.Run(Form1);" But I really got no clue how my classes can interact with the form and create a flow like I described above. I mean, I just have these "...._Click(object sender....)" for each "item" inside the form. Now I do not know where to place / start my flow / loop, and how my classes can interact with the form. thanks and regards daemonfire

    Read the article

  • Console.Write Not Working In Win Forms App

    - by Steven
    I created a VB.NET Windows Forms Application in Visual Studio 2008. When I run my program from the command-line, I get no output (only the next prompt). What am I doing wrong? Private Sub Form1_Load(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles MyBase.Load Debug.Write("Foo") Debug.Flush() Console.WriteLine("foo") Console.Beep(800, 100) 'confirm this function is called' Me.Close() End Sub EDIT: Can a program have a form and a console? EDIT2: Ho's answer works. However, the output appears on the next command-line prompt. Can a Winforms application tell the command-line to wait until it's finished instead of immediately returning?

    Read the article

  • Hiding the console window in a system() call

    - by Justen
    Continuing from this question With each system call, the function constructs a set of parameters and sends them off to another program that is just console-based. Is there a way I can make it so that no console window pops up for each call? I've done a search but the ones that aren't a linker issue just aren't working for me. For instance, I tried the _execl call and System::Diagnostics::Process^ myProcess = gcnew System::Diagnostics::Process; but they aren't working. The _execl will bring a console window up, scroll a bunch of stuff (from the program I called I guess), then close the my app and not even do what it was supposed to do. The System::Diagnostics::Process^ myProcess = gcnew System::Diagnostics::Process; doesn't seem to execute what I want either because the output folder that should contain files, contains nothing. So I'm open for ideas.

    Read the article

  • How to Redirect a Python Console output to a QTextBox

    - by krishnanunni
    Hello, I'm working on developing a GUI for the recompilation of Linux kernel. For this I need to implement 4-5 Linux commands from Python. I use Qt as GUI designer. I have successfully implemented the commands using os.system() call. But the output is obtained at the console. The real problem is the output of command is a listing that takes almost 20-25 min continuous printing. How we can transfer this console output to a text box designed in Qt. Can any one help me to implement the setSource() operation in Qt using source as the live console outputs.

    Read the article

  • rails - Redirecting console output to a file

    - by egarcia
    On a bash console, if I do this: cd mydir ls -l > mydir.txt The operator captures the standard input and redirects it to a file; so I get the listing of files in mydir.txt instead of in the standard output. Is there any way to do something similar on the rails console? I've got a ruby statement that generates lots of prints (~8k lines) and I'd like to be able to see it completely, but the console only "remembers" the last 1024 lines or so. So I thought about redirecting to a file - If anyone knows a better option, I'm all ears.

    Read the article

  • keep open windows console after a python syntax error

    - by basweber
    File associations on my machine (winxp home) are such that a python script is directly opened with the python interpreter. If I double click on a python script a console window runs and every thing is fine - as long as there is no syntax error in the script. In that case the console window opens up for a moment but it is closed immediately. Too fast to read the error message. Of course their would be the possibility to manually open a console window and to execute the script by typing python myscript.py but I am sure that there is a more convenient (i.e. "double click based") solution.

    Read the article

  • Console App Mouse-Click X Y Coordinate Detection/Comparison

    - by Bloodyaugust
    I have a game that I am working on in a C# console application, purely as practice before going on to better methods. As opposed to using something such as a Windows Forms App, which has button functionality built in, I am endeavoring to grab the cursor position (which I know how to do) and compare it to a number of area's inside a console application as defined by perhaps pixel location, but I also do not know if there is some sort of built in unit of space other than pixels (this last bit is the part I am unable to figure). P.S. I know this is in general terms, with no code already provided, but I do not feel that it is needed as all I am asking for is a brief explanation of how to grab X Y coordinates inside a console application, and stick them in int variables. Many Thanks in advance! :D

    Read the article

  • console.log() and google chrome

    - by Lorenzo C
    I'm testing a library and I use console.log() function to visualyze values. There is a strange behaviour of Google Chrome (in other browser like Firefox it doesn't happend). If I try to store strings in Array object when I log them, sometimes values appears undefined. Code example (item.name is a string) var arrayItemsSearch = [item.name]; var itemRedrawName = [item.name]; console.log("arrayItemsSearch: ", arrayItemsSearch); console.log("itemRedrawName: ", itemRedrawName); Firefox output is correct arrayItemsSearch: ["elem[0]"] itemRedrawName: ["elem[0]"] Chrome output is not correct arrayItemsSearch: [undefined × 1] itemRedrawName: ["elem[0]"] Is this a Chrome bug? Or is this beacuse in Javascript strings are immutable objects and so something that I don't understand goes wrong?

    Read the article

  • Virtual PC: Cannot restore machine from hibernate

    - by Paul Lammertsma
    I have two virtual machines set up from Virtual PC on Windows 7 Professional: Windows XP Mode and Xubuntu. Last time I used them (last month or so), I had closed them by hibernating. Evidently, I have meanwhile downloaded a Windows Update affecting VPC and now receive the following error in restoring either of them from hibernation: 'Xubuntu' could not be restored because of either host processor type mismatch or lack of hardware-assisted virtualization support in the system. I've been through the virtual machine's settings, and there's nowhere an option to simply reboot it. (Virtualization is not the problem, as I can create a new virtual machine without any problems.) Any ideas?

    Read the article