Search Results

Search found 3617 results on 145 pages for 'physical wear'.

Page 80/145 | < Previous Page | 76 77 78 79 80 81 82 83 84 85 86 87  | Next Page >

  • Why is my mdadm raid-1 recovery so slow?

    - by dimmer
    On a system I'm running Ubuntu 10.04. My raid-1 restore started out fast but quickly became ridiculously slow (at this rate the restore will take 150 days!): dimmer@paimon:~$ cat /proc/mdstat Personalities : [linear] [multipath] [raid0] [raid1] [raid6] [raid5] [raid4] [raid10] md0 : active raid1 sdc1[2] sdb1[1] 1953513408 blocks [2/1] [_U] [====>................] recovery = 24.4% (477497344/1953513408) finish=217368.0min speed=113K/sec unused devices: <none> Eventhough I have set the kernel variables to reasonably quick values: dimmer@paimon:~$ cat /proc/sys/dev/raid/speed_limit_min 1000000 dimmer@paimon:~$ cat /proc/sys/dev/raid/speed_limit_max 100000000 I am using 2 2.0TB Western Digital Hard Disks, WDC WD20EARS-00M and WDC WD20EARS-00J. I believe they have been partitioned such that their sectors are aligned. dimmer@paimon:/sys$ sudo parted /dev/sdb GNU Parted 2.2 Using /dev/sdb Welcome to GNU Parted! Type 'help' to view a list of commands. (parted) p Model: ATA WDC WD20EARS-00M (scsi) Disk /dev/sdb: 2000GB Sector size (logical/physical): 512B/512B Partition Table: gpt Number Start End Size File system Name Flags 1 1049kB 2000GB 2000GB ext4 (parted) unit s (parted) p Number Start End Size File system Name Flags 1 2048s 3907028991s 3907026944s ext4 (parted) q dimmer@paimon:/sys$ sudo parted /dev/sdc GNU Parted 2.2 Using /dev/sdc Welcome to GNU Parted! Type 'help' to view a list of commands. (parted) p Model: ATA WDC WD20EARS-00J (scsi) Disk /dev/sdc: 2000GB Sector size (logical/physical): 512B/4096B Partition Table: gpt Number Start End Size File system Name Flags 1 1049kB 2000GB 2000GB ext4 I am beginning to think that I have a hardware problem, otherwise I can't imagine why the mdadm restore should be so slow. I have done a benchmark on /dev/sdc using Ubuntu's disk utility GUI app, and the results looked normal so I know that sdc has the capability to write faster than this. I also had the same problem on a similar WD drive that I RMAd because of bad sectors. I suppose it's possible they sent me a replacement with bad sectors too, although there are no SMART values showing them yet. Any ideas? Thanks. As requested, output of top sorted by cpu usage (notice there is ~0 cpu usage). iowait is also zero which seems strange: top - 11:35:13 up 2 days, 9:40, 3 users, load average: 2.87, 2.58, 2.30 Tasks: 142 total, 1 running, 141 sleeping, 0 stopped, 0 zombie Cpu(s): 0.0%us, 0.2%sy, 0.0%ni, 99.8%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Mem: 3096304k total, 1482164k used, 1614140k free, 617672k buffers Swap: 1526132k total, 0k used, 1526132k free, 535416k cached PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 45 root 20 0 0 0 0 S 0 0.0 2:17.02 scsi_eh_0 1 root 20 0 2808 1752 1204 S 0 0.1 0:00.46 init 2 root 20 0 0 0 0 S 0 0.0 0:00.00 kthreadd 3 root RT 0 0 0 0 S 0 0.0 0:00.02 migration/0 4 root 20 0 0 0 0 S 0 0.0 0:00.17 ksoftirqd/0 5 root RT 0 0 0 0 S 0 0.0 0:00.00 watchdog/0 6 root RT 0 0 0 0 S 0 0.0 0:00.02 migration/1 ... dmesg errors, definitely looking like hardware: [202884.000157] ata5.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen [202884.007015] ata5.00: failed command: FLUSH CACHE EXT [202884.013728] ata5.00: cmd ea/00:00:00:00:00/00:00:00:00:00/a0 tag 0 [202884.013730] res 40/00:00:ff:59:2e/00:00:35:00:00/e0 Emask 0x4 (timeout) [202884.033667] ata5.00: status: { DRDY } [202884.040329] ata5: hard resetting link [202889.400050] ata5: link is slow to respond, please be patient (ready=0) [202894.048087] ata5: COMRESET failed (errno=-16) [202894.054663] ata5: hard resetting link [202899.412049] ata5: link is slow to respond, please be patient (ready=0) [202904.060107] ata5: COMRESET failed (errno=-16) [202904.066646] ata5: hard resetting link [202905.840056] ata5: SATA link up 3.0 Gbps (SStatus 123 SControl 300) [202905.849178] ata5.00: configured for UDMA/133 [202905.849188] ata5: EH complete [203899.000292] ata5.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen [203899.007096] ata5.00: failed command: IDENTIFY DEVICE [203899.013841] ata5.00: cmd ec/00:01:00:00:00/00:00:00:00:00/00 tag 0 pio 512 in [203899.013843] res 40/00:00:ff:f9:f6/00:00:38:00:00/e0 Emask 0x4 (timeout) [203899.041232] ata5.00: status: { DRDY } [203899.048133] ata5: hard resetting link [203899.816134] ata5: SATA link up 3.0 Gbps (SStatus 123 SControl 300) [203899.826062] ata5.00: configured for UDMA/133 [203899.826079] ata5: EH complete [204375.000200] ata5.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen [204375.007421] ata5.00: failed command: IDENTIFY DEVICE [204375.014799] ata5.00: cmd ec/00:01:00:00:00/00:00:00:00:00/00 tag 0 pio 512 in [204375.014800] res 40/00:00:ff:0c:0f/00:00:39:00:00/e0 Emask 0x4 (timeout) [204375.044374] ata5.00: status: { DRDY } [204375.051842] ata5: hard resetting link [204380.408049] ata5: link is slow to respond, please be patient (ready=0) [204384.440076] ata5: SATA link up 3.0 Gbps (SStatus 123 SControl 300) [204384.449938] ata5.00: configured for UDMA/133 [204384.449955] ata5: EH complete [204395.988135] ata5.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen [204395.988140] ata5.00: failed command: IDENTIFY DEVICE [204395.988147] ata5.00: cmd ec/00:01:00:00:00/00:00:00:00:00/00 tag 0 pio 512 in [204395.988149] res 40/00:00:ff:0c:0f/00:00:39:00:00/e0 Emask 0x4 (timeout) [204395.988151] ata5.00: status: { DRDY } [204395.988156] ata5: hard resetting link [204399.320075] ata5: SATA link up 3.0 Gbps (SStatus 123 SControl 300) [204399.330487] ata5.00: configured for UDMA/133 [204399.330503] ata5: EH complete

    Read the article

  • Authorization error when testing FTP to UNC

    - by user64204
    We have a Windows Server 2008 R2 with Active Directory (hereafter called DC) running as a domain controller on which we have IIS and an FTP site installed. We have a second Server 2008 (hereafter called SHARE) which is joined to that domain and has a disk shared as a network share (\\share\Office). That network share is used as the ftp's physical path on DC. We've tested the FTP from the IIS FTP configuration panel, by clicking on Basic Settings... then Test Settings.... When setting Administrator as a username with the Connect as... option, everything is fine: When no user is provided we can the below error: Q1: Could someone explain in more understandable terms what is written in the Details text area?

    Read the article

  • Identify SATA hard drive

    - by Rob Nicholson
    Very similar question to: Physically Identify the failed hard drive But for Windows 2003 this time. Scenario: Four identical SATA hard drives plugged into motherboard (no RAID controller here) Configured as single drive in Windows as a spanned volume One of them is starting to fail with error "The driver detected a controller error on \Device\Harddisk3" How do you cross-reference Harddisk3 to the physical SATA connection on the motherboard so you know which drive to replace? I know replacing this drive will trash the spanned array requiring it to be rebuilt anyway so my rough and ready solution is: Delete the spanned partition Create individual partitions on each drive labelled E: F: G: and H: and work out which one is Harddisk3 Power down, remove each disk one at a time, power-up until the drive letter disappears But this seems a rather crude method of identifying the drive. The SATA connectors will be numbered on the motherboard but I appreciate this might not cross-match to what Windows calls them. Thanks, Rob.

    Read the article

  • File not updating in symlink'd folder in IIS

    - by Daniel Short
    I have the following setup: Site1/Shared/ - Physical folder Site2/Shared/ - symlink using mklink to Site1/Shared I've updated a javascript file in Site1/Shared/scripts, and the change is being reflected on Site1. However, the change is not being reflected through IIS on Site2. When I open Site1/Shared/scripts/common.js and Site2/Shared/scripts/common.js, they match exactly. But when I view the files through Safari, Firefox, Chrome, IE, from any machine (even machines that have never visited the sites), the change is not reflected on Site2. Here are URLs to the files to review: Site 1: http://www.landsofamerica.com/shared/scripts/common.js Site 2: http://www.landsoftexas.com/shared/scripts/common.js These files look exactly the same when logged onto the server, and the shared folder under landsoftexas.com is a symlink created using mklink to the shared folder under landsofamerica.com. Any idea what might be causing IIS to serve the wrong file?

    Read the article

  • Debian 5 is randomly shutting down.

    - by revofreak
    My debian 5 vps is suffering from random shutdowns. I reinstalled it several times, the hosts moved me to a different physical box, check the install image and said everyone else also uses it and is fine. Heres the output from syslog Mar 27 00:19:19 noobintraining-1 -- MARK -- Mar 27 00:32:01 noobintraining-1 shutdown[18142]: shutting down for system halt Mar 27 00:32:06 noobintraining-1 init: Switching to runlevel: 0 Mar 27 00:32:06 noobintraining-1 xinetd[15907]: Exiting... Mar 27 00:32:07 noobintraining-1 named[15865]: received control channel command 'stop -p' Mar 27 00:32:07 noobintraining-1 named[15865]: shutting down: flushing changes Mar 27 00:32:07 noobintraining-1 named[15865]: stopping command channel on 127.0.0.1#953 Mar 27 00:32:07 noobintraining-1 named[15865]: stopping command channel on ::1#953 Mar 27 00:32:07 noobintraining-1 named[15865]: no longer listening on ::#53 Mar 27 00:32:07 noobintraining-1 named[15865]: no longer listening on 127.0.0.1#53 Mar 27 00:32:07 noobintraining-1 named[15865]: no longer listening on 89.238.172.132#53 Mar 27 00:32:07 noobintraining-1 named[15865]: exiting Mar 27 00:32:07 noobintraining-1 exiting on signal 15 Any help is most appreciated!

    Read the article

  • What does the fan speed sensor really report?

    - by T. Verron
    I have an overheating issue on my netbook (ASUS EeePC 1015PW), which I'm trying to troubleshoot. Using lm-sensors while overheating gave me this output : acpitz-virtual-0 Adapter: Virtual device temp1: +86.0°C (crit = +100.0°C) eeepc-isa-0000 Adapter: ISA adapter fan1: 4089 RPM coretemp-isa-0000 Adapter: ISA adapter Core 0: +82.0°C (crit = +100.0°C) Core 1: +80.0°C (crit = +100.0°C) But I can't hear the fan. So I enabled manual pwm controling and set the fan to full speed, and after a few minutes I got this output : acpitz-virtual-0 Adapter: Virtual device temp1: +65.0°C (crit = +100.0°C) eeepc-isa-0000 Adapter: ISA adapter fan1: 4016 RPM coretemp-isa-0000 Adapter: ISA adapter Core 0: +62.0°C (crit = +100.0°C) Core 1: +58.0°C (crit = +100.0°C) And this time I could hear the fan spinning. So there's quite obviously an issue with either fan control or fan monitoring. Hence the question : what kind of physical information does the fan sensor really report? Thank you PS. I should have added that the computer is a small, hard-to-disassemble netbook, so I can't and don't want to try experiments like "block the fan and see what the sensor reports".

    Read the article

  • Gparted: Copy Greyed Out

    - by David
    I booted my system to a gparted linux live CD and I have two partitions: /dev/sda1 /dev/sda2 I want to move both of them to my new physical hard drive (called /dev/sdb). When I right click on /dev/sda1, I can choose copy and then paste it onto /dev/sdb. When I right click on /dev/sda2, copy is greyed out and there is a yellow exclamation point to the left of the disk. I know that the disk works since I can boot my computer from it. Why won't gparted let me copy /dev/sda2 to my new hard disk? Since the option is greyed out, I don't even get an error message. Thanks!

    Read the article

  • Planning to buy a server with at least 48GB Ram, are the blades way to go?

    - by varchar1
    We're planning to host our website for the first time for ourselves. We have currently have a linode of 8 gigs and the memory is going up to 90% most of the time. So I want to move my website to my own server with huge RAM. So this will be first time to manage any physical hardware of a server. So I came across IBM's BladeCenter, found them interesting. So can I just buy the blade and run it? Or do I have to buy the chassis for sure? Also, do I need to buy an UPS? So how hard is it to setup? How about the hard drives? Can I setup them easily? Please advice.

    Read the article

  • Change user login in Windows 7 (after a misprint in username)

    - by Artem Russakovskii
    I have an install of Windows 7 that I've already put a few days into. Today I realized I've made a mistake in the username and it's driving me nuts (my personal OCD). While changing the physical folder name is perhaps possible, though quite involved, I do not want to open that can of worms. What I want to do is simply change the username I give when the login prompt shows up. I thought it's possible by just renaming the user account in the User Accounts but that didn't work. Is it possible to do then? Or is the only way to create another user and spend hour migrating everything I'd already customized to that user?

    Read the article

  • IPv4 private address assignment

    - by helloworld922
    I'm working on a private network which uses static IPv4 addresses as well as DHCP addressing for the physical LAN network. At a previous company I worked at they would assign static addresses in the 10.*.*.* space and all DHCP/LAN addresses were assigned in the 192.168.*.* space. Both of these address spaces are defined in the IPv4 private address space and there were never any internal conflicts. From personal experience at home, school, at work, and pretty much any other machine I've dealt with extensively (Windows and a few Linux distros), the DHCP server would always by default choose an address from the 192.168.*.* address space. Now my question is can I rely on this behavior? Do DHCP servers always by default assign from the 192.168.*.* pool (or any pool other than the 10.*.*.* pool), leaving the 10.*.*.* pool free for private static addressing? If not, under what conditions might a DHCP server choose an address in the 10.*.*.* address space?

    Read the article

  • DHCP for Multiple Subnets

    - by TheD
    So this is the current setup - essentially I would like to get my DHCP server, serving DHCP requests for two seperate subnets. Netgear DG834G acting as a modem connected to a Sonicwall Pro 2040. X0 - LAN - 192.168.1.0/24 X1 - WAN - <WAN-IP> X2 - WLAN - 192.168.10.0/24 At the moment, I have a 2008R2 server with DHCP installed, with an IP address on the 192.168.1.0/24 range handling DHCP fine for this subnet. The Sonicwall is configured correctly - anything connected to the WLAN has Full Allow to anything in the LAN, and vice versa but it will not lease an IP from my Server. I've also added another IP address to the server, so the physical NIC now has two IP's: 192.168.1.2 and 192.168.10.2 with a DHCP scope configured for each. Still no luck! Any ideas? Thanks!

    Read the article

  • Have an iPad's viewable area visible on your computer monitor for remote web-meeting training?

    - by MikeN
    I want to demo the usage of my iPad on my computer screen so that I can transmit it to other people during a training session using a web conference tool (like dimdim.com, gotomeeting.com, fuzemeeting.com, etc...) Is there a way to stream an iPad's display to a computer so it would be visible in such a screen casting software? My current ad-hoc solution for this would be to use a webcam to livecast me using a physical (real life) iPad and broadcast that to other users for training. This is undesirable due to the difficulty in really seeing the iPad well. So I'm hoping someone has a way to do: 1) Video output the iPad's display to my computer screen. 2) Emulate an iPad with a installed app (not having the source code) on the screen.

    Read the article

  • Windows Vista - Can't start any program without choosing "Run as administrator"

    - by Dave Forgac
    A friend called me saying that her computer recently said it was applying a Windows update when it was shutting down. Now when logged in as her normal user whenever she tries to run any program from the start menu or from a shortcut on the desktop she gets the following popup: "Windows cannot access the specified device path or file You may not have the appropriate permissions to access the item" If she right-clicks and chooses 'Run as administrator' the program will run. We checked the Windows update history and it said the update was applied successfully and that there are no updates available. Unfortunately I'm in a different city so I don't have physical access to the system to look at it any further. Has anyone had a similar problem or have any suggestions?

    Read the article

  • MySQL Windows vs. Linux: performance, caveats, pros and cons?

    - by gravyface
    Looking for (preferrably) some hard data or at least some experienced anecdotal responses with regards to hosting a MySQL database (roughly 5k transactions a day, 60-70% more reads than writes, < 100k of data per transaction i.e. no large binary objects like images, etc.) on Windows 2003/2008 vs. a Debian-based derivative (Ubuntu/Debian, etc.). This server will function only as a database server with a separate Web server on another physical box; this server will require remote access for management (SSH for Linux, RDP for Windows). I suspect that the Linux kernel/OS will compete less than the Windows Server for resources, but for this I can't be certain. There's also security footprint: even with Windows 2008, I'm thinking that the Linux box can be locked down more easily than the Windows Server. Anyone have any experience with both configurations?

    Read the article

  • Windows 8.1 installation: Which drive is the F drive?

    - by sammyg
    I am doing a clean install of Windows 8.1 on an old PC. It was purchased as download from Microsoft Store and written to and booted from a USB flash drive. It went through all of these steps: Copying Windows Files Getting files ready for installation Installing features Installing updates Then at "Getting finished" I am stuck at this stupid dialog box. Please unplug the following external drive and click OK to restart your computer and finish installing Windows. F: How do I tell what physical drive this is? Can I drop to command prompt during installation? And is it safe to unplug it while powered on? There is no external hard drive connected, none that I can see. There is no USB or FireWire drive connected externally. I think it sees one of the internal drives as external... in some weird way?!

    Read the article

  • HP DL380 G5 Predictive Drive Failure on a new drive

    - by CharlieJ
    Consolidated Error Report: Controller: Smart Array P400 in slot 3 Device: Physical Drive 1I:1:1 Message: Predictive failure. We have an HP DL380 G5 server with two 72GB 15k SAS drives configured in RAID1. A couple weeks ago, the server reported a drive failure on Drive 1. We replaced the drive with a brand new HDD -- same spares number. A few days ago, the server started reporting a predictive drive failure on the new drive, in the same bay. Is it likely the new drive is bad... or more likely we have a bay failure problem? This is a production server, so any advice would be appreciated. I have another spare drive, so I can hot swap it if this is a fluke and new drive is just bad. THANKS! CharlieJ

    Read the article

  • Renting an "EC2" server VS buying one (for a start up in initial stages)

    - by krish p
    We are a small start up in the early stages and are working on a SaaS-based Rails product. Currently, we use EC2 for a small instance and have a need for another large/extra-large instance as we are beginning to deploy to the Cloud and get ready to release our "alpha" version. While EC2 was my choice for numerous reasons (reliability, accessibility - small team is geographically dispersed, maintainability, and things of that nature), it appears to be rather expensive. While the product will ultimately be deployed in the Cloud (be it EC2 or otherwise) and that experience would help the development team, would it make sense to purchase a physical server and stick it in the basement or bite the bullet and pay the price for EC2 (or other Cloud Providers)? While such decisions are driven by numerous factors, it would certainly help to get the thoughts of other folks who may have been in similar situations. Hence, the post. Thanks much!

    Read the article

  • Why is my USB-to-VGA'd monitor working, but not showing in Display Settings?

    - by Strilanc
    I have a USB-to-VGA adapter, which I use to connect a second monitor to my laptop (totaling 3 screens). It worked alright with Vista. I upgraded to Windows 7, and now it no longer works properly (I downloaded the latest drivers just to get it to work on 7). The extra monitor is detected and used to extend the desktop (I can move things onto it, etc), but is not shown within the Control Panel. This is annoying because now I can't changes its resolution, set its logical position to match its physical position, etc. Can I do anything, besides waiting for better drivers? I'm mainly concerned with moving its logical position. (I'd also like to understand how Windows can use a monitor it can't detect. Weird.)

    Read the article

  • How to change the amount of RAM displayed in System Properties

    - by Nicu Zecheru
    I have this product that requires at least 1 GB Physical Memory in order to be installed. On my XP Pro machine I have 1 GB of RAM but in System Properties only 0.99 GB of RAM is displayed. The problem is that the product installer checks the memory displayed in System Properties (just a guess, not sure) and cannot continue the setup because it sees only 0.99 GB. Is there any way to change the displayed memory in the System Properties? Or how can I trick the installer to skip the memory check? Thanks.

    Read the article

  • How to check if PAE is enabled? (Windows 7 32 bits)

    - by Altar
    How to tell for sure if PAE (Physical Address Extensions) is enabled or not? There is a SPECIFIC command I can use? I can read a registry value or something? (Windows 7 32 bits) I have found this on Internet but it doesn't answer my question: If your server has hot-add memory ability (ability to add more memory without shutting down the server !!) or data execution prevention (DEP) is enabled then PAE will be enabled automatically !! It only reformulate the question as "does my Qosmio x505 laptop support hot-add memory?"

    Read the article

  • organizing images by resolution with batch files

    - by Anthony
    Doing some digging I'm trying to figure out a command line solution for organizing very large archives of images based on their resolution into folders, 1920x1080, 1600x1200, 1600x900, etc. I've come across a few post on Superuser mentioning something called ImageMagick, is that the best method to the madness I'm trying to accomplish? I've never used any command line functions/applets/tools other then those that come from Microsoft. I'm rather new to command line usage but ive been enjoying the hell out of it using Powershell, xcopy and robocopy. I am slowly trying to push myself further into the Linux world with Ubuntu running on one of my physical machines as well as a virtual machine so that's an option as well.

    Read the article

  • Migrating an Active Directory domain controller to AWS

    - by Xavier Hutchinson
    I am required to migrate a Active Directory server into AWS with a couple other servers (SQL and IIS) to create a dev and test environment for our network / development. My plan at this time is to simply rebuild the Active Directory server in AWS from scratch - which is quite time consuming indeed! I was wondering if anyone had a recommendation as to a better and more efficient approach of migrating a copy of a physical Active Directory server to the cloud? The server is Windows Server 2012. Thank you!

    Read the article

  • How do you manage large web farms?

    - by Andrew Katz
    I have a quickly growing web farm running IIS 7 (30+ servers). All servers are identical copies of each other and all servers are physical. We update the software about once a month, and in the current process, we follow the following steps: Disable server from pool on F5 load balancer. Disable HTTP Keep-alives in IIS so connections drop quickly. Change default directory of website to new folder containing new binaries. Test server Enable HTTP Keep-alives. Enable server in F5 pool. Move to server 2 Microsoft used to have Application Center which was abandoned a while ago. They have made a second attempt with the Web Farm Framework, but this adds as much QA time testing the release package as it saves in the deployment. Has anyone seen a commercial off the shelf application that is tailored for managing and deploying to large web farms? Thanks!

    Read the article

  • Only One GPU Detected in the Nvidia Quadro NVS 450

    - by Kyle Brandt
    I just built myself an new workstation and now only 2 of 3 monitors are working. I built the nvidia driver by downloading it and installing with ./Nvidia... Before when I ran nvidia-settings I saw two GPUs listed but now I only see one. Xorg Config (Not sure how I ended up with 3 devices in there): # nvidia-settings: X configuration file generated by nvidia-settings # nvidia-settings: version 256.35 (buildmeister@builder101) Wed Jun 16 19:25:39 PDT 2010 Section "ServerLayout" # Removed Option "Xinerama" "1" Identifier "Layout0" Screen 0 "Screen0" 0 0 Screen 1 "Screen1" RightOf "Screen0" InputDevice "Keyboard0" "CoreKeyboard" InputDevice "Mouse0" "CorePointer" Option "Xinerama" "0" EndSection Section "Files" EndSection Section "InputDevice" # generated from default Identifier "Mouse0" Driver "mouse" Option "Protocol" "auto" Option "Device" "/dev/psaux" Option "Emulate3Buttons" "no" Option "ZAxisMapping" "4 5" EndSection Section "InputDevice" # generated from default Identifier "Keyboard0" Driver "kbd" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor0" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor1" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor2" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Device" Identifier "Device0" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:6:0:0" EndSection Section "Device" Identifier "Device1" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:5:0:0" EndSection Section "Device" Identifier "Device2" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:3:0:0" EndSection Section "Screen" # Removed Option "TwinView" "0" # Removed Option "metamodes" "DFP-0: nvidia-auto-select +0+0" # Removed Option "metamodes" "DFP-0: nvidia-auto-select +0+275, DFP-3: nvidia-auto-select +1680+0" Identifier "Screen0" Device "Device0" Monitor "Monitor0" DefaultDepth 24 Option "TwinView" "1" Option "TwinViewXineramaInfoOrder" "DFP-3" Option "metamodes" "DFP-0: nvidia-auto-select +0+0, DFP-3: nvidia-auto-select +1680+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" # Removed Option "metamodes" "DFP-3: nvidia-auto-select +0+0" Identifier "Screen1" Device "Device1" Monitor "Monitor1" DefaultDepth 24 Option "TwinView" "0" Option "metamodes" "nvidia-auto-select +0+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" Identifier "Screen2" Device "Device2" Monitor "Monitor2" DefaultDepth 24 Option "TwinView" "0" Option "metamodes" "nvidia-auto-select +0+0" SubSection "Display" Depth 24 EndSubSection EndSection lscpi: 00:00.0 Host bridge: Intel Corporation 5520/5500/X58 I/O Hub to ESI Port (rev 13) 00:01.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 1 (rev 13) 00:02.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 2 (rev 13) 00:03.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 3 (rev 13) 00:10.0 PIC: Intel Corporation 5520/5500/X58 Physical and Link Layer Registers Port 0 (rev 13) 00:10.1 PIC: Intel Corporation 5520/5500/X58 Routing and Protocol Layer Registers Port 0 (rev 13) 00:11.0 PIC: Intel Corporation 5520/5500 Physical and Link Layer Registers Port 1 (rev 13) 00:11.1 PIC: Intel Corporation 5520/5500 Routing & Protocol Layer Register Port 1 (rev 13) 00:13.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub I/OxAPIC Interrupt Controller (rev 13) 00:14.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub System Management Registers (rev 13) 00:14.1 PIC: Intel Corporation 5520/5500/X58 I/O Hub GPIO and Scratch Pad Registers (rev 13) 00:14.2 PIC: Intel Corporation 5520/5500/X58 I/O Hub Control Status and RAS Registers (rev 13) 00:15.0 PIC: Intel Corporation 5520/5500/X58 Trusted Execution Technology Registers (rev 13) 00:1a.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #4 00:1a.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #5 00:1a.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #6 00:1a.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #2 00:1b.0 Audio device: Intel Corporation 82801JI (ICH10 Family) HD Audio Controller 00:1c.0 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 1 00:1c.1 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Port 2 00:1c.3 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 4 00:1c.4 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 5 00:1d.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #1 00:1d.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #2 00:1d.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #3 00:1d.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #1 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev 90) 00:1f.0 ISA bridge: Intel Corporation 82801JIR (ICH10R) LPC Interface Controller 00:1f.2 IDE interface: Intel Corporation 82801JI (ICH10 Family) 4 port SATA IDE Controller #1 00:1f.3 SMBus: Intel Corporation 82801JI (ICH10 Family) SMBus Controller 00:1f.5 IDE interface: Intel Corporation 82801JI (ICH10 Family) 2 port SATA IDE Controller #2 01:00.0 IDE interface: Device 1b4b:91a3 (rev 11) 02:00.0 USB Controller: NEC Corporation Device 0194 (rev 03) 03:00.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 04:00.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 04:02.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 05:00.0 3D controller: nVidia Corporation G98 [Quadro NVS 450] (rev a1) 06:00.0 VGA compatible controller: nVidia Corporation G98 [Quadro NVS 450] (rev a1) 08:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 08:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 09:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 09:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 0a:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 06) 0b:06.0 FireWire (IEEE 1394): Texas Instruments TSB43AB23 IEEE-1394a-2000 Controller (PHY/Link)

    Read the article

  • Simple NAT router for ESX

    - by Evan M.
    Hi Guys, I'm looking for a simple virtual appliance that I can deploy to my ESX environment to use as a virtual NAT router / firewall to create an isolated network that I can easily give internet access too. Basic setup: ESX Host, has 2 vswitches configured: 1 is connected to the physical LAN, the other is isolated. I need an appliance that I can add 2 vNICs to, and attach one to the isolated vSwitch, the other to the LAN, to give the isolated network outbound access (so it can reach the internet). Anyone have an appliance that I can setup quickly to do so? Thanks.

    Read the article

< Previous Page | 76 77 78 79 80 81 82 83 84 85 86 87  | Next Page >