Search Results

Search found 14403 results on 577 pages for 'visual studiob'.

Page 80/577 | < Previous Page | 76 77 78 79 80 81 82 83 84 85 86 87  | Next Page >

  • How can I get all the .pdb files in the same folder?

    - by uvts_cvs
    I have a solution in Visual Studio 2008, it has dozens of projects. I would like to have all the pdb in the same folder. From the property page of a project I see that the pdb will go to the "Intermediate Directory"; also .obj files go to the "Intermediate Directory". Each of our projects has its own folder because we want to keep the .obj separated, at the same time I would like to have all the pdb in the same folder. Looking at the buildlog.htm I see the option /PDB which controls the pdb path, this option doesn't seem to me available in the property page. Maybe I will have to use a post buil script?

    Read the article

  • The type initializer for {Data.DataModule} threw an exception.

    - by squirms
    In visual basic, when in the "frmMain Events: Load", I get the following error The type initializer for 'projData.projDataModule' threw an exception. when running the code: var = 180 "var" is defined in projDataModule as Module projDataModule Public var As Double End Module When I rebuild the solution, It says "0 errors, 0 warnings" and will actually compile, however the Error list shows the following error: Error 1 Custom tool error: Failed to generate file: There is an error in XML document (1, 1). I:\Documents and Settings\Bill\Desktop\Projects\Data\My Project\Application.myapp 1 1 Data Any ideas or help at all would be greatly appreciated. Thanks in advance.

    Read the article

  • Model binding broke after upgrade to Visual Studio 2010

    - by John
    I have an ASP.net MVC 1.0 VS2008 application that I just opened in Visual Studio 2010. When I did this Studio upgraded the app from VS2008 to the VS2010 project. It also upgraded the MVC references from 1.0 to 2.0. In my app I have a class for a form post, I then use the class for the model binding in the Action method so it will auto populate the values. This worked fine in mvc 1.0 but now it does not work in 2.0 after the upgrade. Does does anyone know why? Or where I should look to resolve this? Here is my class, public class Add_Postal_Form_Input { public string ACTION_RDO { get; set; } public string POSTALSELECT { get; set; } public string CNY_CD { get; set; } public string S_PST_LOW { get; set; } public string R_PST_LOW { get; set; } public string R_PST_HI { get; set; } public string G_PST_LOW { get; set; } public string G_GRP_CD { get; set; } public string CAT_CD { get; set; } public string SUB_CD { get; set; } public string ATTR_VAL { get; set; } public string NBG_HR { get; set; } public string NBG_MN { get; set; } public string REC_STT_DT { get; set; } public string REC_END_DT { get; set; } public string DEFAULT_DATE { get; set; } } Here is the method, [AcceptVerbs("POST")] public PartialViewResult AddData(Add_Postal_Form_Input FORM_IN) { Thanks

    Read the article

  • How do you insert new entries into an Access db table through an ASP.net website?

    - by CGF
    I need to insert new records into an Access database. I'm using Visual Studio 2008 and firstly create a asp.net website. I can connect to the information in Access databse using dataview or gridview and can query a particular entry (ie. Proposal No. -brings up all details linking to that proposal). I can then edit the details of that proposal and this would update the Access Db. What I need to do is to have a form that simply enters new details for a new customer. ie. Enter name [__] Enter Adress[__]. Then for this to update the database. By using the gridview or dataview I am able to view all fields that exist in the table and edit them. Is there a way that I can get a blank gridview/dataview template (which includes all the fields in the table) and fill it out to then update the database? Thanks

    Read the article

  • How do I get Visual Studio build process to pass condition to library(external) project

    - by Billy Talented
    I have tried several solutions for this problem. Enough to know I do not know enough about MSBuild to do this elegantly but I feel like there should be a method. I have a set of libraries for working with .net projects. A few of the projects utilize System.Web.Mvc - which recently released Version 2 - and we are looking forward to the upgrade. Currently sites which reference this library reference it directly by the project(csproj) on the developer's computer - not a built version of the library so that changes and source code case easily be viewed when dealing code from this library. This works quite well and would prefer to not have to switch to binary references (but will if this is the only solution). The problem I have is that because of some of the functionality that was added onto the MVC1 based library (view engines, model binders etc) several of the sites reliant on these libraries need to stay on MVC1 until we have full evaluated and tested them on MVC2. I would prefer to not have to fork or have two copies on each dev machine. So what I would like to be able to do is set a property group value in the referencing web application and have this read by the above mentions library with the caviat that when working directly on the library via its containing solution I would like to be able to control this via Configuration Manager by selecting a build type and that property overriding the build behavior of the solution (i.e. 'Debug - MVC1' vs 'Debug -MVC2') - I have this working via: <Choose> <When Condition=" '$(Configuration)|$(Platform)' == 'Release - MVC2|AnyCPU' Or '$(Configuration)|$(Platform)' == 'Debug - MVC2|AnyCPU'"> <ItemGroup> <Reference Include="System.Web.Mvc, Version=2.0.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35, processorArchitecture=MSIL"> </Reference> <Reference Include="Microsoft.Web.Mvc, Version=1.0.0.0, Culture=neutral, processorArchitecture=MSIL"> <SpecificVersion>False</SpecificVersion> <HintPath>..\Dependancies\Web\MVC2\Microsoft.Web.Mvc.dll</HintPath> </Reference> </ItemGroup> </When> <Otherwise> <ItemGroup> <Reference Include="System.Web.Mvc, Version=1.0.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35, processorArchitecture=MSIL"> <SpecificVersion>False</SpecificVersion> <HintPath>..\Dependancies\Web\MVC\System.Web.Mvc.dll</HintPath> </Reference> </ItemGroup> </Otherwise> The item that I am struggling with is the cross solution issue(solution TheWebsite references this project and needs to control which build property to use) that I have not found a way to work with that I think is a solid solution that enabled the build within visual studio to work as it has to date. Other bits: we are using VS2008, Resharper, TeamCity for CI, SVN for source control.

    Read the article

  • "Exception has been thrown by the target of an invocation" Running Tests - VS2008 SP1

    - by omatrot
    I'm using Visual Studio 2008 Team Suite and I'm unable to run tests and display the Test/Windows/Test Result Window. The result is a dialog box with the following content : "Exception has been thrown by the target of an invocation". Team Explorer has been installed after Visual Studio 2008 SP1. So I have re-apllied the service pack. Searching the web I found that this error is pretty common but unfortunately, the proposed solutions does not work for me. The problem was never analysed so I decided to give it a try : I reproduced the problem on a computer, attached the process with windbg and start with the basic investigations. Following are the first results : 0:000>!dumpstack OS Thread Id: 0xdb0 (0) Current frame: USER32!NtUserWaitMessage+0x15 ChildEBP RetAddr Caller,Callee 003fec94 75a32674 USER32!DialogBox2+0x222, calling USER32!NtUserWaitMessage 003fecd0 75a3288a USER32!InternalDialogBox+0xe5, calling USER32!DialogBox2 003fecfc 75a6f8d0 USER32!SoftModalMessageBox+0x757, calling USER32!InternalDialogBox 003fed3c 6eb61996 mscorwks!Thread::ReverseLeaveRuntime+0x95, calling mscorwks!_EH_epilog3 003fedb0 75a6fbac USER32!MessageBoxWorker+0x269, calling USER32!SoftModalMessageBox 003fede0 6ea559c3 mscorwks!SetupThreadNoThrow+0x19a, calling mscorwks!_EH_epilog3_catch_GS 003fee24 6eb61d8a mscorwks!HasIllegalReentrancy+0xac, calling mscorwks!_EH_epilog3 003fee30 6ea89796 mscorwks!SimpleComCallWrapper::Release+0x2e, calling mscorwks!CompareExchangeMP 003fee38 6ea0da05 mscorwks!CLRException::HandlerState::CleanupTry+0x16, calling mscorwks!GetCurrentSEHRecord 003fee44 6ea0c9c0 mscorwks!Thread::EnablePreemptiveGC+0xf, calling mscorwks!Thread::CatchAtSafePoint 003fee4c 6ea8a241 mscorwks!Unknown_Release_Internal+0x24d, calling mscorwks!GCHolder<1,0,0>::Pop 003fee50 6ea0c86c mscorwks!_EH_epilog3_catch_GS+0xa, calling mscorwks!__security_check_cookie 003fee54 6ea8a24c mscorwks!Unknown_Release_Internal+0x258, calling mscorwks!_EH_epilog3_catch_GS 003fee7c 75a16941 USER32!UserCallWinProcCheckWow+0x13d, calling ntdll!RtlDeactivateActivationContextUnsafeFast 003feed8 7082119e msenv!ATL::CComCritSecLock<ATL::CComCriticalSection>::Lock+0xd, calling ntdll!RtlEnterCriticalSection 003fef08 75a6fe5b USER32!MessageBoxIndirectW+0x2e, calling USER32!MessageBoxWorker 003fef7c 70a1e367 msenv!MessageBoxPVoidW+0xda 003fefd4 70a1db60 msenv!VBDialogCover2+0x11b 003ff01c 70a1e4c0 msenv!VBMessageBox2W+0xf0, calling msenv!VBDialogCover2 003ff044 7087246b msenv!main_GetAppNameW+0xa, calling msenv!GetAppNameInternal 003ff04c 70a1e4f2 msenv!VBMessageBox3W+0x1c, calling msenv!VBMessageBox2W 003ff064 70a1d6d7 msenv!_IdMsgShow+0x362, calling msenv!VBMessageBox3W 003ff0cc 70951841 msenv!TaskDialogCallback+0x7e0, calling msenv!_IdMsgShow 003ff118 6eb20da4 mscorwks!Unknown_QueryInterface+0x230, calling mscorwks!_EH_epilog3_catch_GS 003ff14c 6eb20c43 mscorwks!Unknown_QueryInterface_Internal+0x3d8, calling mscorwks!_EH_epilog3_catch_GS 003ff168 02006ec4 02006ec4, calling 0247a1e8 003ff16c 6ea0c86c mscorwks!_EH_epilog3_catch_GS+0xa, calling mscorwks!__security_check_cookie 003ff198 6eb20562 mscorwks!COMToCLRWorker+0xb34, calling mscorwks!_EH_epilog3_catch_GS 003ff19c 0247a235 0247a235, calling mscorwks!COMToCLRWorker 003ff1c4 7083249f msenv!CVSCommandTarget::ExecCmd+0x937 003ff1e4 7086d5c8 msenv!VsReportErrorInfo+0x11, calling msenv!TaskDialogCallback+0xd8 003ff1f8 7093e65b msenv!CVSCommandTarget::ExecCmd+0x945, calling msenv!VsReportErrorInfo 003ff25c 7081f53a msenv!ATL::CComPtr<IVsLanguageInfo>::~CComPtr<IVsLanguageInfo>+0x24, calling msenv!_EH_epilog3 003ff260 70b18d72 msenv!LogCommand+0x4c, calling msenv!ATL::CComPtr<IVsCodePageSelection>::~CComPtr<IVsCodePageSelection> 003ff264 70b18d77 msenv!LogCommand+0x51, calling msenv!_EH_epilog3 003ff280 70a4fd0e msenv!CMsoButtonUser::FClick+0x1d1, calling msenv!CVSCommandTarget::ExecCmd 003ff2f4 70823a87 msenv!CTLSITE::QueryInterface+0x16 003ff31c 70cb7d4d msenv!TBCB::FNotifyFocus+0x204 003ff35c 70ce5fda msenv!TB::NotifyControl+0x101 003ff3bc 709910f6 msenv!TB::FRequestFocus+0x4ed, calling msenv!TB::NotifyControl 003ff414 708254ba msenv!CMsoButtonUser::FEnabled+0x3d, calling msenv!GetQueryStatusFlags 003ff428 7086222a msenv!TBC::FAutoEnabled+0x24 003ff43c 7098e1eb msenv!TB::LProcessInputMsg+0xdb4 003ff458 6bec1c49 (MethodDesc 0x6bcd7f54 +0x89 System.Windows.Forms.Form.DefWndProc(System.Windows.Forms.Message ByRef)), calling 6be3b738 003ff50c 70823ab0 msenv!FPtbFromSite+0x16 003ff520 70991c43 msenv!TB::PtbParent+0x25, calling msenv!FPtbFromSite 003ff52c 708dda49 msenv!TBWndProc+0x2da 003ff588 0203d770 0203d770, calling 0247a1e8 003ff598 70822a70 msenv!CPaneFrame::Release+0x118, calling msenv!_EH_epilog3 003ff5b0 75a16238 USER32!InternalCallWinProc+0x23 003ff5dc 75a168ea USER32!UserCallWinProcCheckWow+0x109, calling USER32!InternalCallWinProc 003ff620 75a16899 USER32!UserCallWinProcCheckWow+0x6a, calling ntdll!RtlActivateActivationContextUnsafeFast 003ff654 75a17d31 USER32!DispatchMessageWorker+0x3bc, calling USER32!UserCallWinProcCheckWow 003ff688 70847f2b msenv!CMsoComponent::FPreTranslateMessage+0x72, calling msenv!MainFTranslateMessage 003ff6b4 75a17dfa USER32!DispatchMessageW+0xf, calling USER32!DispatchMessageWorker 003ff6c4 70831553 msenv!EnvironmentMsgLoop+0x1ea, calling USER32!DispatchMessageW 003ff6f8 708eb9bd msenv!CMsoCMHandler::FPushMessageLoop+0x86, calling msenv!EnvironmentMsgLoop 003ff724 708eb94d msenv!SCM::FPushMessageLoop+0xb7 003ff74c 708eb8e9 msenv!SCM_MsoCompMgr::FPushMessageLoop+0x28, calling msenv!SCM::FPushMessageLoop 003ff768 708eb8b8 msenv!CMsoComponent::PushMsgLoop+0x28 003ff788 708ebe4e msenv!VStudioMainLogged+0x482, calling msenv!CMsoComponent::PushMsgLoop 003ff7ac 70882afe msenv!CVsActivityLogSingleton::Instance+0xdf, calling msenv!_EH_epilog3 003ff7d8 70882afe msenv!CVsActivityLogSingleton::Instance+0xdf, calling msenv!_EH_epilog3 003ff7dc 707e4e31 msenv!VActivityLogStartupEntries+0x42 003ff7f4 7081f63b msenv!ATL::CComPtr<IClassFactory>::~CComPtr<IClassFactory>+0x24, calling msenv!_EH_epilog3 003ff7f8 708b250f msenv!ATL::CComQIPtr<IUnknown,&IID_IUnknown>::~CComQIPtr<IUnknown,&IID_IUnknown>+0x1d, calling msenv!_EH_epilog3 003ff820 708e7561 msenv!VStudioMain+0xc1, calling msenv!VStudioMainLogged 003ff84c 2f32aabc devenv!util_CallVsMain+0xff 003ff878 2f3278f2 devenv!CDevEnvAppId::Run+0x11fd, calling devenv!util_CallVsMain 003ff97c 77533b23 ntdll!RtlpAllocateHeap+0xe73, calling ntdll!_SEH_epilog4 003ff9f0 77536cd7 ntdll!RtlpLowFragHeapAllocFromContext+0x882, calling ntdll!RtlpSubSegmentInitialize 003ffa10 7753609f ntdll!RtlNtStatusToDosError+0x3b, calling ntdll!RtlNtStatusToDosErrorNoTeb 003ffa14 775360a4 ntdll!RtlNtStatusToDosError+0x40, calling ntdll!_SEH_epilog4 003ffa40 775360a4 ntdll!RtlNtStatusToDosError+0x40, calling ntdll!_SEH_epilog4 003ffa44 75bd2736 kernel32!LocalBaseRegOpenKey+0x159, calling ntdll!RtlNtStatusToDosError 003ffa48 75bd2762 kernel32!LocalBaseRegOpenKey+0x22a, calling kernel32!_SEH_epilog4 003ffac4 75bd2762 kernel32!LocalBaseRegOpenKey+0x22a, calling kernel32!_SEH_epilog4 003ffac8 75bd28c9 kernel32!RegOpenKeyExInternalW+0x130, calling kernel32!LocalBaseRegOpenKey 003ffad8 75bd28de kernel32!RegOpenKeyExInternalW+0x211 003ffae0 75bd28e5 kernel32!RegOpenKeyExInternalW+0x21d, calling kernel32!_SEH_epilog4 003ffb04 6f282e2b MSVCR90!_unlock+0x15, calling ntdll!RtlLeaveCriticalSection 003ffb14 75bd2642 kernel32!BaseRegCloseKeyInternal+0x41, calling ntdll!NtClose 003ffb28 75bd25d0 kernel32!RegCloseKey+0xd4, calling kernel32!_SEH_epilog4 003ffb5c 75bd25d0 kernel32!RegCloseKey+0xd4, calling kernel32!_SEH_epilog4 003ffb60 2f321ea4 devenv!DwInitSyncObjects+0x340 003ffb90 2f327bf4 devenv!WinMain+0x74, calling devenv!CDevEnvAppId::Run 003ffbac 2f327c68 devenv!License::GetPID+0x258, calling devenv!WinMain 003ffc3c 75bd3677 kernel32!BaseThreadInitThunk+0xe 003ffc48 77539d72 ntdll!__RtlUserThreadStart+0x70 003ffc88 77539d45 ntdll!_RtlUserThreadStart+0x1b, calling ntdll!__RtlUserThreadStart 0:000> !pe -nested Exception object: 050aae9c Exception type: System.Reflection.TargetInvocationException Message: Exception has been thrown by the target of an invocation. InnerException: System.NullReferenceException, use !PrintException 050aac64 to see more StackTrace (generated): SP IP Function 003FEC2C 6D2700F7 mscorlib_ni!System.RuntimeType.CreateInstanceSlow(Boolean, Boolean)+0x57 003FEC5C 6D270067 mscorlib_ni!System.RuntimeType.CreateInstanceImpl(Boolean, Boolean, Boolean)+0xe7 003FEC94 6D270264 mscorlib_ni!System.Activator.CreateInstance(System.Type, Boolean)+0x44 003FECA4 6AD02DAF Microsoft_VisualStudio_Shell_9_0_ni!Microsoft.VisualStudio.Shell.Package.CreateToolWindow(System.Type, Int32, Microsoft.VisualStudio.Shell.ProvideToolWindowAttribute)+0x67 003FED30 6AD0311B Microsoft_VisualStudio_Shell_9_0_ni!Microsoft.VisualStudio.Shell.Package.CreateToolWindow(System.Type, Int32)+0xb7 003FED58 6AD02D12 Microsoft_VisualStudio_Shell_9_0_ni!Microsoft.VisualStudio.Shell.Package.FindToolWindow(System.Type, Int32, Boolean, Microsoft.VisualStudio.Shell.ProvideToolWindowAttribute)+0x7a 003FED88 6AD02D39 Microsoft_VisualStudio_Shell_9_0_ni!Microsoft.VisualStudio.Shell.Package.FindToolWindow(System.Type, Int32, Boolean)+0x11 003FED94 02585E30 Microsoft_VisualStudio_QualityTools_TestCaseManagement!Microsoft.VisualStudio.TestTools.TestCaseManagement.QualityToolsPackage.InitToolWindowVariable[[System.__Canon, mscorlib]](System.__Canon ByRef, System.String, Boolean)+0x58 003FEDD0 02585DBE Microsoft_VisualStudio_QualityTools_TestCaseManagement!Microsoft.VisualStudio.TestTools.TestCaseManagement.QualityToolsPackage.InitToolWindowVariable[[System.__Canon, mscorlib]](System.__Canon ByRef, System.String)+0x36 003FEDE4 02585D32 Microsoft_VisualStudio_QualityTools_TestCaseManagement!Microsoft.VisualStudio.TestTools.TestCaseManagement.QualityToolsPackage.ShowToolWindow[[System.__Canon, mscorlib]](System.__Canon ByRef, System.String, Boolean)+0x3a 003FEE00 02585AB4 Microsoft_VisualStudio_QualityTools_TestCaseManagement!Microsoft.VisualStudio.TestTools.TestCaseManagement.QualityToolsPackage.OpenTestResultsToolWindow()+0x2c 003FEE10 02585A6E Microsoft_VisualStudio_QualityTools_TestCaseManagement!Microsoft.VisualStudio.TestTools.TestCaseManagement.QualityToolsPackage.OnMenuViewTestResults(System.Object, System.EventArgs)+0x6 003FEE18 6CD4F993 System_ni!System.ComponentModel.Design.MenuCommand.Invoke()+0x43 003FEE40 6CD4F9D4 System_ni!System.ComponentModel.Design.MenuCommand.Invoke(System.Object)+0x8 003FEE48 6AD000FA Microsoft_VisualStudio_Shell_9_0_ni!Microsoft.VisualStudio.Shell.OleMenuCommandService.Microsoft.VisualStudio.OLE.Interop.IOleCommandTarget.Exec(System.Guid ByRef, UInt32, UInt32, IntPtr, IntPtr)+0x11a 003FEEA0 6AD03FB8 Microsoft_VisualStudio_Shell_9_0_ni!Microsoft.VisualStudio.Shell.Package.Microsoft.VisualStudio.OLE.Interop.IOleCommandTarget.Exec(System.Guid ByRef, UInt32, UInt32, IntPtr, IntPtr)+0x44 StackTraceString: <none> HResult: 80131604 0:000> !PrintException 050aac64 Exception object: 050aac64 Exception type: System.NullReferenceException Message: Object reference not set to an instance of an object. InnerException: <none> StackTrace (generated): SP IP Function 003FE660 078E60BE Microsoft_VisualStudio_TeamSystem_Integration!Microsoft.VisualStudio.TeamSystem.Integration.TcmResultsPublishManager..ctor(Microsoft.VisualStudio.TeamSystem.Integration.ResultsPublishManager)+0xc6 003FE674 078E5C91 Microsoft_VisualStudio_TeamSystem_Integration!Microsoft.VisualStudio.TeamSystem.Integration.ResultsPublishManager..ctor(Microsoft.VisualStudio.TeamSystem.Integration.TeamFoundationHostHelper)+0x59 003FE684 078E2FA0 Microsoft_VisualStudio_TeamSystem_Integration!Microsoft.VisualStudio.TeamSystem.Integration.VsetServerHelper..ctor(System.IServiceProvider)+0x50 003FE6A4 078E2E90 Microsoft_VisualStudio_TeamSystem_Common!Microsoft.VisualStudio.TeamSystem.Integration.Client.VsetHelper.InitializeThrow(System.IServiceProvider)+0x20 003FE6B8 078E2E2A Microsoft_VisualStudio_TeamSystem_Common!Microsoft.VisualStudio.TeamSystem.Integration.Client.VsetHelper.InitializeHelper(System.IServiceProvider)+0x22 003FE6E0 078E2DEC Microsoft_VisualStudio_TeamSystem_Common!Microsoft.VisualStudio.TeamSystem.Integration.Client.VsetHelper.CreateVsetHelper(System.IServiceProvider)+0x1c 003FE6F0 078E2DAC Microsoft_VisualStudio_QualityTools_TestCaseManagement!Microsoft.VisualStudio.TestTools.TestCaseManagement.QualityToolsPackage.get_VsetHelper()+0x14 003FE6F8 02586BBE Microsoft_VisualStudio_QualityTools_TestCaseManagement!Microsoft.VisualStudio.TestTools.TestCaseManagement.ResultsToolWindow..ctor()+0x9f6 003FE798 02585F8A Microsoft_VisualStudio_QualityTools_TestCaseManagement!Microsoft.VisualStudio.TestTools.TestCaseManagement.ResultToolWindowHost..ctor()+0x1a StackTraceString: <none> HResult: 80004003 In order to be able to continue the analysis, we need to get the parameters to see what is going on. I also tried to run devenv.exe with the /log switch. No error in the log after reproducing the problem. Finally, If Team Explorer is removed from the system, the problem goes away. Any help appreciated. TIA. Olivier.

    Read the article

  • Generating .coverage file programmatic way with Visual Studio 2010

    - by prosseek
    I need to generate .coverage file programmatic way. This post explains a C# code to do it as follows. using System; using System.Collections.Generic; using System.Text; using System.Diagnostics; using Microsoft.VisualStudio.Coverage; using Microsoft.VisualStudio.Coverage.Analysis; // You must add a reference to Microsoft.VisualStudio.Coverage.Monitor.dll namespace Microsoft.VisualStudio { class DumpProgram { static void Main(string[] args) { Process p = new Process(); StringBuilder sb = new StringBuilder("/COVERAGE "); sb.Append("hello.exe"); p.StartInfo.FileName = "vsinstr.exe"; p.StartInfo.Arguments = sb.ToString(); p.Start(); p.WaitForExit(); // TODO: Look at return code – 0 for success // A guid is used to keep track of the run Guid myrunguid = Guid.NewGuid(); Monitor m = new Monitor(); m.StartRunCoverage(myrunguid, "hello.coverage"); // Complete the run m.FinishRunCoverage(myrunguid); Unfortunately, when I compile this code, I get the following error. bin2xml.cs(26,22): error CS0246: The type or namespace name 'Monitor' could not be found (are you missing a using directive or an assembly reference?) bin2xml.cs(26,38): error CS0246: The type or namespace name 'Monitor' could not be found (are you missing a using directive or an assembly reference?) As this post says, there are some changes between VS2008 and VS2010, I think the Monitor class is in some different namespace. What might be wrong? How can I generate the .coverage file programmatically with Visual Studio 2010? ADDED I added using System.Threading to run to get the following error. I run the command csc bin2xml.cs /r:Microsoft.VisualStudio.Coverage.Analysis.dll. bin2xml.cs(28,21): error CS0723: Cannot declare a variable of static type 'System.Threading.Monitor' bin2xml.cs(28,33): error CS0712: Cannot create an instance of the static class 'System.Threading.Monitor' bin2xml.cs(29,23): error CS1061: 'System.Threading.Monitor' does not contain a definition for 'StartRunCoverage' and no extension method 'StartRunCoverage' accepting a first argument of type 'System.Threading.Monitor' could be found (are you missing a using directive or an assembly reference?) bin2xml.cs(31,23): error CS1061: 'System.Threading.Monitor' does not contain a definition for 'FinishRunCoverage' and no extension method 'FinishRunCoverage' accepting a first argument of type 'System.Threading.Monitor' could be found (are you missing a using directive or an assembly reference?) ADDED2 I compiled the code with the following command. csc bin2xml.cs /r:Microsoft.VisualStudio.Coverage.Analysis.dll /r:Microsoft.VisualStudio.Coverage.Monitor.dll Then, I got these error messages. Monitor m = new Monitor(); is at the line 27. bin2xml.cs(27,21): error CS0246: The type or namespace name 'Monitor' could not be found (are you missing a using directive or an assembly reference?) bin2xml.cs(27,37): error CS0246: The type or namespace name 'Monitor' could not be found (are you missing a using directive or an assembly reference?)

    Read the article

  • Unable to connect SQL Server instance from Visual Studio 2008 Version 9.0

    - by salvationishere
    I am getting the below error from VS on an 32-bit XP Professional server even though I set Tools-Options-Database Tools-Data Connections to "SIDEKICK", which is the name of my computer. In other words SIDEKICK should default to the full SQLSERVER. In other words, I want VS to use SQLSERVER instead of SQLSERVER EXPRESS. And I can clearly see my database both from VS in the Server Explorer and also in SSMS 2008. Furthermore, I can view the tables of this database in Server Explorer from VS. I do not get any build errors. And it looks like all of the naming is consistent in my web.config file. I am developing my website according to a Microsoft tutorial, so I should not be getting an error. Yet I get the following exception when I run this code below: CreateAccounts.aspx.cs file protected void CreateAccountButton_Click(object sender, EventArgs e) { MembershipCreateStatus createStatus; //This line below is where the exception occurs MembershipUser newUser = Membership.CreateUser(Username.Text, Password.Text, Email.Text, passwordQuestion, SecurityAnswer.Text, true, out createStatus); And here is what the exception looks like: System.Web.HttpException was unhandled by user code Message="Unable to connect to SQL Server database." Source="System.Web" ErrorCode=-2147467259 StackTrace: at System.Web.DataAccess.SqlConnectionHelper.CreateMdfFile(String fullFileName, String dataDir, String connectionString) at System.Web.DataAccess.SqlConnectionHelper.EnsureSqlExpressDBFile(String connectionString) at System.Web.DataAccess.SqlConnectionHelper.GetConnection(String connectionString, Boolean revertImpersonation) at System.Web.Security.SqlMembershipProvider.CreateUser(String username, String password, String email, String passwordQuestion, String passwordAnswer, Boolean isApproved, Object providerUserKey, MembershipCreateStatus& status) at System.Web.Security.Membership.CreateUser(String username, String password, String email, String passwordQuestion, String passwordAnswer, Boolean isApproved, Object providerUserKey, MembershipCreateStatus& status) at System.Web.Security.Membership.CreateUser(String username, String password, String email, String passwordQuestion, String passwordAnswer, Boolean isApproved, MembershipCreateStatus& status) at Membership_CreatingUserAccounts.CreateAccountButton_Click(Object sender, EventArgs e) in c:\Documents and Settings\Admin\My Documents\Visual Studio 2008\WebSites\WebSite2\Membership\CreatingUserAccounts.aspx.cs:line 24 at System.Web.UI.WebControls.Button.OnClick(EventArgs e) at System.Web.UI.WebControls.Button.RaisePostBackEvent(String eventArgument) at System.Web.UI.WebControls.Button.System.Web.UI.IPostBackEventHandler.RaisePostBackEvent(String eventArgument) at System.Web.UI.Page.RaisePostBackEvent(IPostBackEventHandler sourceControl, String eventArgument) at System.Web.UI.Page.RaisePostBackEvent(NameValueCollection postData) at System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint) InnerException: System.Web.HttpException Message="Unable to connect to SQL Server database." Source="System.Web" ErrorCode=-2147467259 StackTrace: at System.Web.Management.SqlServices.GetSqlConnection(String server, String user, String password, Boolean trusted, String connectionString) at System.Web.Management.SqlServices.SetupApplicationServices(String server, String user, String password, Boolean trusted, String connectionString, String database, String dbFileName, SqlFeatures features, Boolean install) at System.Web.Management.SqlServices.Install(String database, String dbFileName, String connectionString) at System.Web.DataAccess.SqlConnectionHelper.CreateMdfFile(String fullFileName, String dataDir, String connectionString) InnerException: System.Data.SqlClient.SqlException Message="The user instance login flag is not supported on this version of SQL Server. The connection will be closed." Source=".Net SqlClient Data Provider" ErrorCode=-2146232060 Class=14 LineNumber=65536 Number=18493 Procedure="" Server="." State=1 StackTrace: at System.Data.SqlClient.SqlInternalConnection.OnError(SqlException exception, Boolean breakConnection) at System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj) at System.Data.SqlClient.TdsParser.Run(RunBehavior runBehavior, SqlCommand cmdHandler, SqlDataReader dataStream, BulkCopySimpleResultSet bulkCopyHandler, TdsParserStateObject stateObj) at System.Data.SqlClient.SqlInternalConnectionTds.CompleteLogin(Boolean enlistOK) at System.Data.SqlClient.SqlInternalConnectionTds.AttemptOneLogin(ServerInfo serverInfo, String newPassword, Boolean ignoreSniOpenTimeout, Int64 timerExpire, SqlConnection owningObject) at System.Data.SqlClient.SqlInternalConnectionTds.LoginNoFailover(String host, String newPassword, Boolean redirectedUserInstance, SqlConnection owningObject, SqlConnectionString connectionOptions, Int64 timerStart) at System.Data.SqlClient.SqlInternalConnectionTds.OpenLoginEnlist(SqlConnection owningObject, SqlConnectionString connectionOptions, String newPassword, Boolean redirectedUserInstance) at System.Data.SqlClient.SqlInternalConnectionTds..ctor(DbConnectionPoolIdentity identity, SqlConnectionString connectionOptions, Object providerInfo, String newPassword, SqlConnection owningObject, Boolean redirectedUserInstance) at System.Data.SqlClient.SqlConnectionFactory.CreateConnection(DbConnectionOptions options, Object poolGroupProviderInfo, DbConnectionPool pool, DbConnection owningConnection) at System.Data.ProviderBase.DbConnectionFactory.CreateNonPooledConnection(DbConnection owningConnection, DbConnectionPoolGroup poolGroup) at System.Data.ProviderBase.DbConnectionFactory.GetConnection(DbConnection owningConnection) at System.Data.ProviderBase.DbConnectionClosed.OpenConnection(DbConnection outerConnection, DbConnectionFactory connectionFactory) at System.Data.SqlClient.SqlConnection.Open() at System.Web.Management.SqlServices.GetSqlConnection(String server, String user, String password, Boolean trusted, String connectionString) InnerException: The web.config connection string looks like: <connectionStrings> <add name="SecurityTutorialsConnectionString" connectionString="data source=.;Integrated Security=SSPI;AttachDBFilename=|DataDirectory|SecurityTutorialsDatabase3.mdf;User Instance=true" providerName="System.Data.SqlClient"/> </connectionStrings> <system.web> <membership defaultProvider="SecurityTutorialsSqlMembershipProvider"> <providers> <add name="SecurityTutorialsSqlMembershipProvider" type="System.Web.Security.SqlMembershipProvider" connectionStringName="SecurityTutorialsConnectionString" enablePasswordRetrieval="false" enablePasswordReset="true" requiresQuestionAndAnswer="true" applicationName="SecurityTutorials" requiresUniqueEmail="true" passwordFormat="Hashed" maxInvalidPasswordAttempts="5" minRequiredPasswordLength="7" minRequiredNonalphanumericCharacters="1" passwordAttemptWindow="10" passwordStrengthRegularExpression=""/> </providers> </membership>

    Read the article

  • Link List Implementation Help - Visual C++

    - by Greenhouse Gases
    Hi there I'm trying to implement a link list which stores the city name (though you will see this commented out as I need to resolve the issue of not being able to use string and needing to use a primitive data type instead during the declaration), longitude, latitude and of course a pointer to the next node in the chain. I am new to the Visual C++ environment and my brain is somewhat scrambled after coding for several straight hours today so I wondered if anyone could help resolve the 2 errors I am getting (ignore the #include syntax as I had to change them to avoid the browser interpreting html!): 1U08221.obj : error LNK2028: unresolved token (0A000298) "public: __thiscall Locations::Locations(void)" (??0Locations@@$$FQAE@XZ) referenced in function "int __clrcall main(cli::array^)" (?main@@$$HYMHP$01AP$AAVString@System@@@Z) 1U08221.obj : error LNK2019: unresolved external symbol "public: __thiscall Locations::Locations(void)" (??0Locations@@$$FQAE@XZ) referenced in function "int __clrcall main(cli::array^)" (?main@@$$HYMHP$01AP$AAVString@System@@@Z) The code for my header file is here: include string struct locationNode { //char[10] nodeCityName; double nodeLati; double nodeLongi; locationNode* Next; }; class Locations { private: int size; public: Locations(); // constructor for the class locationNode* Head; int Add(locationNode* Item); }; and here is the code for the file containing the main method: // U08221.cpp : main project file. include "stdafx.h" include "Locations.h" include iostream include string using namespace std; int n = 0; int x; string cityNameInput; bool acceptedInput = false; int Locations::Add(locationNode *NewItem) { locationNode *Sample = new locationNode; Sample = NewItem; Sample-Next = Head; Head = Sample; return size++; } void CorrectCase(string name) // Correct upper and lower case letters of input { x = name.size(); int firstLetVal = name[0], letVal; n = 1; // variable for name index from second letter onwards if((name[0] 90) && (name[0] < 123)) // First letter is lower case { firstLetVal = firstLetVal - 32; // Capitalise first letter name[0] = firstLetVal; } while(n <= x - 1) { if((name[n] = 65) && (name[n] <= 90)) { letVal = name[n] + 32; name[n] = letVal; } n++; } cityNameInput = name; } void nameValidation(string name) { n = 0; // start from first letter x = name.size(); while(!acceptedInput) { if((name[n] = 65) && (name[n] <= 122)) // is in the range of letters { while(n <= x - 1) { while((name[n] =91) && (name[n] <=97)) // ERROR!! { cout << "Please enter a valid city name" << endl; cin name; } n++; } } else { cout << "Please enter a valid city name" << endl; cin name; } if(n <= x - 1) { acceptedInput = true; } } cityNameInput = name; } int main(array ^args) { cout << "Enter a city name" << endl; cin cityNameInput; nameValidation(cityNameInput); // check is made up of valid characters CorrectCase(cityNameInput); // corrects name to standard format of capitalised first letter, and lower case subsequent letters cout << cityNameInput; cin cityNameInput; Locations::Locations(); Locations *Parts = new Locations(); locationNode *Part; Part = new locationNode; //Part-nodeCityName = "London"; Part-nodeLati = 87; Part-nodeLongi = 80; Parts-Add(Part); } I am familiar with the concepts but somewhat inexperienced with OOP so am making some silly errors that you can never find when you've stared at something too long. Any help you can offer will be appreciated! Thanks

    Read the article

  • Producing 64-bit builds on Windows with free software

    - by pauldoo
    Hi, I have a C++ project that I've been developing in Microsoft Visual C++ 2008 Express Edition. It has come to the point that I'd like to port to 64-bit and continue development. What is the best way to do this using free software? My thoughts so far: The Express Edition of MSVC doesn't come with 64-bit compilers, so I can install the Windows SDK to get these. I could then port my project files to nmake, and use the IDE just as a tool to debug and invoke my nmake scripts.. The downside to this is that nmake looks very poor. The example towards the end of this tutorial suggests that nmake cannot figure out source file dependences itself, and I don't know of anything equivelant to gcc -M that I could use. Another option might be to use vcbuild from the Windows SDK to produce 64-bit builds from my existing vcproj files. Preliminary investigations show that this doesn't really work, as my project files don't have the 64-bit configurations present. (Perhaps I could fudge this by adding the 64-bit configurations to the vcproj files in a text editor.) A final option might be to give up on MSVC, and port my project to the MinGW/MSYS toolchain.

    Read the article

  • Which language should I pick up: VB.Net or C#

    - by magius
    I'm looking to pick up either C# or VB.Net. I'd done a fair bit of VB6 programming in the past. I'm looking at getting the book, Visual Basic .NET or C#, Which to Choose? but I'm hoping that someone has read it, or used both languages and can offer advice. Should I just RTFB? Edit: Anders Sandvig raised a valid question. I'm intending to develop ActiveX applications that will be served through IE. Edit: Given that the functionality is pretty close and my favored approach to learning is to "just build it" and solve problems by looking it up on the internet, I've decided that the choice of language will be based on how easy it is to learn it. I looked around and found sites like C# Corner that supports my approach. Personal note: I wish I could also select Seb Nilsson's response as an accepted answer as well. Thanks guys for your input! Alright, then! I admit, theoretically, this topic is subjective; but a quick tally of answers seems to skew votes heavily in C#'s favor. Anyway, I'm really after experiences like what Keith's alluding to. I'm hoping he'll return to this topic and drop us a few more gems.

    Read the article

  • C# visually subclass datagridview control VS2005

    - by DRapp
    Maybe its something stupid, but I'm having a problem with a subclass of a DataGridView Control in VS2005 C#. I know I can subclass from almost anything by doing public class MyDataGridView : DataGridView {} no problem, and I put in some things / elements I want applicable globally. Now, I take this gridview and put into a custom user control that will contain other controls too. So I have something like created by the visual designer. I grab some buttons, label, and my derived "MyDataGridView" on it. public partial class MyCompoundDGVPlus : UserControl So, now, I can visually draw, move, change all sorts of settings as needed, no problem. Now, I want this "MyCompoundDGVPlus" class as the basis for other classes, of which I will manipulate settings specific, but want all to have the same look / feel, and otherwise similar flow, hence the derivations. I've even set the "modifiers" setting to public, so I SHOULD be able to modify any of the properties of the controls at any derived level. So, now, I create a new subclass of "MyFirstDetailedDGVPlus" derived from "MyCompoundDGVPlus". Ok visually, all the label, button, datagridview appear. However, now I want to specifically define the columns of the datagridview here in this class visually, but its locked. However, the LABEL on the form, I CAN get all the property settings.... What am I missing.

    Read the article

  • Why do not C++11's move constructor/assignment operator act as expected

    - by xmllmx
    #include <iostream> using namespace std; struct A { A() { cout << "A()" << endl; } ~A() { cout << "~A()" << endl; } A(A&&) { cout << "A(A&&)" << endl; } A& operator =(A&&) { cout << "A& operator =(A&&)" << endl; return *this; } }; struct B { // According to the C++11, the move ctor/assignment operator // should be implicitly declared and defined. The move ctor // /assignment operator should implicitly call class A's move // ctor/assignment operator to move member a. A a; }; B f() { B b; // The compiler knows b is a temporary object, so implicitly // defined move ctor/assignment operator of class B should be // called here. Which will cause A's move ctor is called. return b; } int main() { f(); return 0; } My expected output should be: A() A(A&&) ~A() ~A() However, the actual output is: (The C++ compiler is: Visual Studio 2012) A() ~A() ~A() Is this a bug of VC++? or just my misunderstanding?

    Read the article

  • Connect to a remote Oracle 11g server using OracleClient of .NET 2.0

    - by Raghu M
    I have to connect to a Oracle server on the network using a .NET / C# (Winform) application. I am trying to use System.Data.OracleClient but in vain. Here are the details I can possibly think of (that might help someone reading this question): Platform: Visual Studio 2005 / .NET 2.0 with C# on Windows Vista Home Premium Library: System.Data.OracleClient Server: Oracle 11g (located on the same LAN) Please note that I don't have Oracle installed locally and I have hunted every discussion forum possible for help - but most of them assume local Oracle installation! Here is my connection string: "User Id=TSUSER;Password=ts12TS;Data Source=(DESCRIPTION=(ADDRESS=(PROTOCOL=TCP)(HOST=MyServerIP)(PORT=1521))(CONNECT_DATA=(SERVICE_NAME=ORCL)));" And I get this error: OCIEnvCreate failed with return code -1 but error message text was not available. Stack trace: at System.Data.OracleClient.OciHandle..ctor(OciHandle parentHandle, HTYPE handleType, MODE ocimode, HANDLEFLAG handleflags) at System.Data.OracleClient.OracleInternalConnection.OpenOnLocalTransaction(String userName, String password, String serverName, Boolean integratedSecurity, Boolean unicode, Boolean omitOracleConnectionName) at System.Data.OracleClient.OracleInternalConnection..ctor(OracleConnectionString connectionOptions) at System.Data.OracleClient.OracleConnectionFactory.CreateConnection(DbConnectionOptions options, Object poolGroupProviderInfo, DbConnectionPool pool, DbConnection owningObject) at System.Data.ProviderBase.DbConnectionFactory.CreatePooledConnection(DbConnection owningConnection, DbConnectionPool pool, DbConnectionOptions options) at System.Data.ProviderBase.DbConnectionPool.CreateObject(DbConnection owningObject) at System.Data.ProviderBase.DbConnectionPool.UserCreateRequest(DbConnection owningObject) at System.Data.ProviderBase.DbConnectionPool.GetConnection(DbConnection owningObject) at System.Data.ProviderBase.DbConnectionFactory.GetConnection(DbConnection owningConnection) at System.Data.ProviderBase.DbConnectionClosed.OpenConnection(DbConnection outerConnection, DbConnectionFactory connectionFactory) at System.Data.OracleClient.OracleConnection.Open() at DGKit.Util.DataUtil.Generate() in D:\SVNRoot\sandbox\DGDev\Util\DataUtil.cs:line 68

    Read the article

  • Favourite Features of VS 2010

    - by Noldorin
    With the general public release of Visual Studio 2010 Beta 2 today, this latest version has created a lot of hype and interest. Indeed, the opinion I've gauged is that VS 2010 has resolved a great deal of the minor flaws left over from previous versions, as well as added some particularly useful new code editor and project development tools (in particular the Premium/Ultimate versions). My question here is: what are you favourite new features in VS 2010 that have really got you excited? Or similarly, what are the flaws of VS 2008 that you are most glad to have resolved? There is a wealth of changes in VS 2010, of course, but these are some of the ones that have interested me most (about which I know!). Integrated support for F# (with multi-targeting for .NET 2.0 - 4.0)/ Much improved WPF designer. The VS 2008 was more than a bit buggy at times. Great improvements to the code editor, such as call hierarchy viewing. A decent add-in framework. A greatly expanded testing framework (now capable of database testing, for example) in Premium/Ultimate. Project planning and modelling features in Premium/Ultimate. If I could request one point/feature per post, I think that would be best, so we could vote them individually.

    Read the article

  • VB.NET: Dialog exits when enter pressed?

    - by Camilo Martin
    Hi all; My problem seems to be quite simple, but it's not working the intuitive way. I'm designing a Windows Forms Application, and there is a dialog that should NOT exit when the enter key is pressed, instead it has to validate data first, in case enter was pressed after changing the text of a ComboBox. I've tried by telling it what to do on KeyPress event of the ComboBox if e is the Enter key: Private Sub ComboBoxSizeChoose_KeyPress(ByVal sender As System.Object, ByVal e As System.Windows.Forms.KeyPressEventArgs) Handles ComboBoxSizeChoose.KeyPress If e.KeyChar = Convert.ToChar(Keys.Enter) Then Try TamanhoDaNovaFonte = Single.Parse(ComboBoxSizeChoose.Text) Catch ex As Exception Dim Dialogo2 As New Dialog2 Dialog2.ShowDialog() ComboBoxSizeChoose.Text = TamanhoDaNovaFonte End Try End If End Sub But no success so far. When the Enter key is pressed, even with the ComboBox on focus, the whole dialog is closed, returning to the previous form. The validation is NOT done at all, and it has to be done before exiting. In fact, I don't even want to exit on the form's enter KeyPress, the only purpose of the enter key on the whole dialog is to validate the ComboBox (but only when in focus, for the sake of an intuitive UI). I've also tried appending the validation to the KeyPress event of the whole dialog's form, if the key is Enter. NO SUCCESS! It's like my code wasn't there at all. What should I do? (Visual Studio 2008, VB.NET)

    Read the article

  • Modifying SQL Database on Shared Hosting

    - by apocalypse9
    I have a live database on a shared hosting server. I am making some major changes to my site's code and I would like to fix some stupid mistakes I made in initially designing the database. These changes involve altering the size of a large number of fields, and enforcing referential integrity between tables properly. I would like to make the changes on both my local test server and the remote server if possible. I should note that while I'm fairly comfortable with writing complex queries to handle data, I have very little experience modifying database structure without a graphical interface. I can access the remote database in the visual studio database explorer but I can not use that for anything other than data manipulation. I installed Sql Management Studio express last night and after 40+ crashes I gave up - I couldn't even patch the damn thing. The remote server is SQL 2005 / The MyLittleAdmin web interface is available. So my question is what is the best way to accomplish these changes. Is there a graphical interface I can use on the remote server? If not is there an easy way to copy the database to my local machine, fix it, and re upload? Finally if none of the above are viable does anyone have links to a decent info on fixing referential integrity via query? Sorry for the somewhat general question - I feel like I am making this far harder than it should be but after searching / trying all night i haven't gotten anywhere. Thanks in advance for the help. I really appreciate it. ...Also does anyone have a time machine I can borrow- I need to go kick my past self's ass for this.

    Read the article

  • Why won't my Setup Project Perform my Custom Registration Process

    - by Jordan S
    I am trying to write an Setup Project/Installer for a class library driver that I wrote in C# using Visual Studio 2008. The driver project has a section of code that looks like this... [ComRegisterFunction] public static void RegisterASCOM(Type t) { Trace.WriteLine("Registration Started."); DoRegistration(true); } In the driver project Properties - "Assembly Information" I have set checked the box that says Make COM-Visible = true. I added a Setup Project to the solution in VS, added the output dll from the driver project so that it installs on the target machine and set the Register property of the dll to "vsdraCOM". So, my understanding is that when the installer runs it SHOULD execute the methods of the dll that are marked with [COMRegisterFunction]. Using SysInternals Debug View I can monitor when the above code snippet is hit by watching for the "Registration started" text to show up in the window. When I build the solution, I can see the text show up so I know the driver is registering properly. The problem is that when I run the installer, I don't think it is doing the registration bit. I see nothing show up in Debug View. And if i try to access my driver via another application I get an error saying it "Cannot create ActiveX object". Why does the registration not occur during the install process? The driver does register for COM but it does NOT call my custom registration method. Does anyone have and suggestions of what I could be missing? Is there another way I can debug this? (I can provide more code if anyone want's to take a look!!)

    Read the article

  • LNK2019 Against CArray Add, GetAt, GetSize, all includes are present

    - by David J
    I'm having some issues trying to Compile a DLL, but I just can't see where this linking error is coming from. My LNK2019 is: Exports.obj : error LNK2019: unresolved external symbol "__declspec(dllimport) public: int __thiscall CArray<struct HWND__ *,struct HWND__ *>::Add(struct HWND__ *)" (__imp_?Add@? $CArray@PAUHWND__@@PAU1@@@QAEHPAUHWND__@@@Z) referenced in function "int __stdcall _Disable(struct HWND__ *,long)" (?_Disable@@YGHPAUHWND__@@J@Z) Disable(...) is... static BOOL CALLBACK _Disable(HWND hwnd, LPARAM lParam) { CArray<HWND, HWND>* pArr = (CHWndArray*)lParam; if(::IsWindowEnabled(hwnd) && ::IsWindowVisible(hwnd)) { pArr->Add(hwnd); ::Enable(hwnd, FALSE); } } This is the first function in Exports.cpp; right above it is #include <afxtempl.h> I have the Windows 7.1 SDK installed (and have tried reinstalling both that and VS2010). The exact same project compiles perfectly fine on other machines, so it can't be the code itself.. I've spent countless errors researching, which led to desperate attempts of just changing random values in the solution file, including different Windows headers, etc. My last resort is getting to be just reinstalling the OS completely (assuming it's actually a problem with the Windows SDK being incorrect or something). Any suggestions at all would be a huge help. EDIT: I've added /showIncludes on the cpp giving issues, and I do see afxtempl.h being included. It's being included multiple times due to other headers including it, but it is there (and it is from the same directory every time): 1> Note: including file: C:\Program Files (x86)\Microsoft Visual Studio 10.0\VC\atlmfc\include\afxtempl.h

    Read the article

  • Compressing a database to a single file?

    - by Assimilater
    Hi all. In my contact manager program I have been storing information by reading and writing comma delimited files for each individual contact, and storing notes in a file for each note, and I'm wondering how I could go about shrinking them all into one file effectively. I have attempted using data entry tools in the visual studio toolbox and template class, though I have never quite figured out how to use them. What would be especially convenient is if I could store data as data type IOwner (a class I created) as opposed to strings. I'd also need to figure out how to tell the program what to do when a file is opened (I've noticed in the properties how to associate a file type with the program though am not sure how to tell it what to do when it's opened). Edit: How about rephrasing the question: I have a class IContact with various properties some of them being lists of other class objects. I have a public list of IContact. Can I write Contacts as List(Of IContact) to a file as opposed to a bunch of strings? Second part of the question: I have associated .cms files with my program. But if a user opens the file, what code should the program run through in an attempt to deal with the file? This file is going to contain data that the program needs to read, how do I tell it to read a file when the program is opened vicariously because the file was opened? Does this make the question clearer?

    Read the article

  • When is a bool not a bool (compiler warning C4800)

    - by omatai
    Consider this being compiled in MS Visual Studio 2005 (and probably others): CPoint point1( 1, 2 ); CPoint point2( 3, 4 ); const bool point1And2Identical( point1 == point2 ); // C4800 warning const bool point1And2TheSame( ( point1 == point2 ) == TRUE ); // no warning What the...? Is the MSVC compiler brain-dead? As far as I can tell, TRUE is #defined as 1, without any type information. So by what magic is there any difference between these two lines? Surely the type of the expression inside the brackets is the same in both cases? [This part of the question now satisfactorily answered in the comments just below] Personally, I think that avoiding the warning by using the == TRUE option is ugly (though less ugly than the != 0 alternative, despite being more strictly correct), and it is better to use #pragma warning( disable:4800 ) to imply "my code is good, the compiler is an ass". Agree? Note - I have seen all manner of discussion on C4800 talking about assigning ints to bools, or casting a burger combo with large fries (hold the onions) to a bool, and wondering why there are strange results. I can't find a clear answer on what seems like a much simpler question... that might just shine line on C4800 in general.

    Read the article

  • Pass arguments to a parameter class object

    - by David R
    This is undoubtedly a simple question. I used to do this before, but it's been around 10 years since I worked in C++ so I can't remember properly and I can't get a simple constructor call working. The idea is that instead of parsing the args in main, main would create an object specifically designed to parse the arguments and return them as required. So: Parameters params = new Parameters(argc, argv) then I can call things like params.getfile() Only problem is I'm getting a complier error in Visual Studio 2008 and I'm sure this is simple, but I think my mind is just too rusty. What I've got so far is really basic: In the main: #include "stdafx.h" #include "Parameters.h" int _tmain(int argc, _TCHAR* argv[]) { Parameters params = new Parameters(argc, argv); return 0; } Then in the Parameters header: #pragma once class Parameters { public: Parameters(int, _TCHAR*[]); ~Parameters(void); }; Finally in the Parameters class: include "Stdafx.h" #include "Parameters.h" Parameters::Parameters(int argc, _TCHAR* argv[]) { } Parameters::~Parameters(void) { } I would appreciate if anyone could see where my ageing mind has missed the really obvious. Thanks in advance.

    Read the article

  • Deprecated functions not spotted if using "System::Threading::ThreadState" (and others!) C++ VS2005/

    - by Fishboy
    Hi, I'm facing an issue with c++ on vs2005 and also vs2008... here's how you can reproduce the issue.... create a new (c++) project called 'test' (file|new|project) select "Windows Forms Application" and add the 'stdio.h' include and the code fragment below into the test.cpp source file..... -------------------start of snippet-------------------- #include <stdio.h> ... int main(array<System::String ^> ^args) { int i; System::Threading::ThreadState state; char str[20]; sprintf (str, "%s", "test string"); ... -------------------end of snippet-------------------- If you compile the code as above (you'll have to 'buildall' first), you'll get two warnings about 'i' and 'state' being unreferenced (nothing about sprintf being deprecated). If you comment out "System::Threading :Thread state;", you'll get one warning about 'i' being unreferenced and another warning (C4996) for the 'deprecated' sprintf statement.... This issue also occurs for "System::Windows::Forms::MessageBoxIcon", "System::Base64FormattingOptions" (and perhap all 'enum class' types!) Anyone know of the cause and workaround to the issue demonstrated here ( i have other files that demonstate this issue..). (I had started a thread on msdn, but then found this site! see link below) Visual Studio 2005 has stopped warning about deprecated functions

    Read the article

  • How repair/uninstall Visual Web Developer 2010 Beta 2?

    - by Sprinter
    I cannot uninstall Visual Web Developer 2010 Beta 2. When I was trying to uninstall the first time, the power went off to my machine and screwed up the Beta 2 installation. I cannot find a Visual Web Developer 2010 Beta 2 download on the Microsoft website any longer to repair the Beta 2 installation. How can I get VWD 2010 Beta 2 off of my system so I can install the new release?

    Read the article

  • Excel tab sheet names vs. Visual Basic sheet names

    - by SteveNeedsSheetNames
    It seems that Visual Basic can not reference sheets according to user-modified sheet names. The worksheet tabs can have their names changed, but it seems that Visual Basic still thinks of the worksheet names as Sheet1, etc., despite the workbook tab having been changed to something useful. I have this: TABname = rng.Worksheet.Name ' Excel sheet TAB name, not VSB Sheetx name. Thanks, Bill Gates. but I would like to use sheet names in Visual Basic routines. The best I could come up so far is to Select Case the Worksheet Tab vs. Visual Basic names, which doesn't make my day. Visual Basic must know the Sheet1, Sheet2, etc., names. How can I get these associated with the Excel tab names so that I don't have to maintain a look-up table which changes with each new sheet or sheet tab re-naming? Thanks in advance for your replies.

    Read the article

< Previous Page | 76 77 78 79 80 81 82 83 84 85 86 87  | Next Page >