Search Results

Search found 8190 results on 328 pages for 'switch'.

Page 84/328 | < Previous Page | 80 81 82 83 84 85 86 87 88 89 90 91  | Next Page >

  • 2 subnets off of 1 PC with 2 NICs

    - by Jeff
    I have a general setup I'd like to do with some IP cameras. This seems like it will work but I think I may be missing something. Our system consists of a video recorder PC connected to a switch which is connected to a number of IP cameras. I'd like to connect this system into an existing network but I want it on a different subnet. The main reason is that the cameras use a lot of bandwidth that I don't want slowing down the existing network. My idea was to install 2 NICs on the video recorder pc. 1 NIC connects to the existing network on 192.169.1.x for example, and the other NIC connect to the switch with the cameras. This NIC would be 192.168.100.x. Then we could remote to the video recorder PC with a GoToMyPC type thing for administration via the existing network. I've included a diagram of how I see this working but I'm a little fuzzy on the setup of the NICs (if this can work at all). My problem may be trying to deal with 2 subnets without a router but It really doesn't seem like it's necessary in this situation. BTW, gliffy is cool.

    Read the article

  • Disabling Keyboard Wakeup for Ubuntu 10.04 on Acer 1810TZ

    - by sybreon
    My Acer Aspire 1810TZ laptop suspends fine but wakes up on any slight key-press. I would like to disable this behaviour. I read that it involves disabling something in the /proc/acpi/wakeup but SLPB does not seem to be listed at all. root@1810TZ:/etc# cat /proc/acpi/wakeup Device S-state Status Sysfs node UHC0 S3 disabled pci:0000:00:1d.0 UHC1 S3 disabled pci:0000:00:1d.1 UHC2 S3 disabled pci:0000:00:1d.2 UHCR S3 disabled EHC1 S3 disabled pci:0000:00:1d.7 UHC3 S3 disabled pci:0000:00:1a.0 UHC4 S3 disabled UHC5 S3 disabled EHC2 S3 disabled pci:0000:00:1a.7 EXP1 S4 disabled pci:0000:00:1c.0 PXSX S4 disabled pci:0000:01:00.0 EXP2 S4 disabled PXSX S4 disabled EXP3 S4 disabled PXSX S4 disabled EXP4 S4 disabled pci:0000:00:1c.3 PXSX S4 disabled pci:0000:02:00.0 EXP5 S4 disabled PXSX S4 disabled EXP6 S4 disabled PXSX S4 disabled However, the relevant bits seem to be detected from dmesg. [ 0.357628] ACPI: AC Adapter [ACAD] (on-line) [ 0.357749] input: Power Button as /devices/LNXSYSTM:00/LNXSYBUS:00/PNP0C0C:00/input/input0 [ 0.357754] ACPI: Power Button [PWRB] [ 0.357817] input: Lid Switch as /devices/LNXSYSTM:00/LNXSYBUS:00/PNP0C0D:00/input/input1 [ 0.359319] ACPI: Lid Switch [LID0] [ 0.359390] input: Sleep Button as /devices/LNXSYSTM:00/LNXSYBUS:00/PNP0C0E:00/input/input2 [ 0.359394] ACPI: Sleep Button [SLPB] [ 0.359475] input: Power Button as /devices/LNXSYSTM:00/LNXPWRBN:00/input/input3 [ 0.359479] ACPI: Power Button [PWRF] Not quite sure what to do next.

    Read the article

  • Maintaining "Portability" Between Linux and Windows 7

    - by lokheart
    I am using the following ways in my office's Windows 7 machine to maintain my "portabilibity" when disaster strikes and I need to switch computer while I have no luxury of time for reinstalling all my program to the new PC. a majority of programs I used are portable, mostly from portableapp.com, like notepad+, GIMP, even R, I extract them and store them in a folder in My document, in a structure similar to the default portableapp installation when they are installed to a thumbdrive only a few software that portable version is not available and I will install them as usual all of my working files are stored in a folder in My document I regularly backup them all using syncback, because this program can keep versioning of my backup, and the backup is stored in a portable drive. One day I need to switch my computer and the operation is relative simple for me: I just move the two folders mentioned above into the my document folder of the new PC, install those few "non-portable" program in it, and this is almost done, some minor hiccups can be solved by reinstalling the portableapp into the drive. Overall speaking it is a smooth process. I would like to maintain the same degree of "portability" in my home Linux desktop (Ubuntu or Mint, I'm still deciding), that is, if my Linux crash and I need to reinstall it again. All I need to do is the move the two folder back to the new Linux, and most of my work will be almost ready to be worked on again. But I don't know how to find a Linux-alternative of portableapps. Being a newer to Linux, can anyone tell me whether this is possible in Linux?

    Read the article

  • How to best tune my SAN/Initiators for best performance?

    - by Disco
    Recent owner of a Dell PowerVault MD3600i i'm experiencing some weird results. I have a dedicated 24x 10GbE Switch (PowerConnect 8024), setup to jumbo frames 9K. The MD3600 has 2 RAID controllers, each has 2x 10GbE ethernet nics. There's nothing else on the switch; one VLAN for SAN traffic. Here's my multipath.conf defaults { udev_dir /dev polling_interval 5 selector "round-robin 0" path_grouping_policy multibus getuid_callout "/sbin/scsi_id -g -u -s /block/%n" prio_callout none path_checker readsector0 rr_min_io 100 max_fds 8192 rr_weight priorities failback immediate no_path_retry fail user_friendly_names yes # prio rdac } blacklist { device { vendor "*" product "Universal Xport" } # devnode "^sd[a-z]" } devices { device { vendor "DELL" product "MD36xxi" path_grouping_policy group_by_prio prio rdac # polling_interval 5 path_checker rdac path_selector "round-robin 0" hardware_handler "1 rdac" failback immediate features "2 pg_init_retries 50" no_path_retry 30 rr_min_io 100 prio_callout "/sbin/mpath_prio_rdac /dev/%n" } } And iscsid.conf : node.startup = automatic node.session.timeo.replacement_timeout = 15 node.conn[0].timeo.login_timeout = 15 node.conn[0].timeo.logout_timeout = 15 node.conn[0].timeo.noop_out_interval = 5 node.conn[0].timeo.noop_out_timeout = 10 node.session.iscsi.InitialR2T = No node.session.iscsi.ImmediateData = Yes node.session.iscsi.FirstBurstLength = 262144 node.session.iscsi.MaxBurstLength = 16776192 node.conn[0].iscsi.MaxRecvDataSegmentLength = 262144 After my tests; i can barely come to 200 Mb/s read/write. Should I expect more than that ? Providing it has dual 10 GbE my thoughts where to come around the 400 Mb/s. Any ideas ? Guidelines ? Troubleshooting tips ?

    Read the article

  • VMWare steals IP addresses

    - by Ishan Amin
    I'm having a peculiar problem, that I think I have narrowed down to VMware. For the past one year, every once in a while we lose internet connection and not all users (about 10 users) go down at the same time, its usually one-by-one. First someone will call me and say "Internet is down" and then we would go reset the router and modem and switch and it would be working again for a while, then go down again without any pattern or replicatable sequence. We'd go repeat the steps again to get everyone in the office running again. We called our Internet Service Provider and they constantly say, We see your modem and we see your router and from thier end everything is OK. we replaced our router and switch and modem, twice! Last friday, it dawned upon me, that everytime we turn on a VMware machine, this sequence of taking everyone down starts, which also explains the message that my users get for "IP Conflict Found" So we do alot of VMware testing and lo and behold, it takes my Internet down. My Yahoo and Gtalk would continue working but www is down when the VMware machines are started. I do use bridged networking to all the VMware machines, but I dont know what else to set it at. now, sorry for this long rambling but anyone have any clue on how to stop this? thanks IA

    Read the article

  • DNS failover in a two datacenter scenario

    - by wanson
    I'm trying to implement a low-cost solution for website high availability. I'm looking for the downsides of the following scenario: I have two servers with the same configuration, content, mysql replication (dual-master). They are in different datacenters - let's call them serverA and serverB. Users use serverA - serverB is more like a backup. Now, I want to use DNS failover, to switch users from serverA to serverB when serverA goes down. My idea is that I setup DNS servers (bind/powerdns) on serverA and serverB - let's call them ns1.website.com and ns2.website.com (assuming I own website.com). Then I configure my domain to use them as its nameservers. Both DNS servers will return serverA IP as my website's IP. If serverA goes down I can (either manually or automatically from serverB) change configuration of serverB's DNS, to return IP of serverB as website's IP. Of course the TTL will be low, as it's supposed to be in DNS failovers. I know that it may take some time to switch to serverB (DNS ttl, time to detect serverA failure, serverB DNS reconfiguration etc), and that some small part of users won't use serverB anyway. And I'm OK with that. But what are other downsides of such an approach? An alternative scenario is that ns1.website.com will return serverA IP as website's IP, and ns2.website.com will return serverB IP as website's IP. But AFAIK clients not always use primary nameserver and sometimes would use secondary one. So some small part of users would use serverB instead of serverA which is not quite what I'd like. Can you confirm that DNS clients behave like that and can you tell what percentage of clients would possibly use serverB instead of serverA (statistically)? This one also has the downside that when serverA goes back up, it will be automatically used as website's primary server, which is also a bad situation (cold cache, mysql replication could fail in the meantime etc). So I'm adding it only as a theoretical alternative. I was thinking about using some professional DNS failover companies but they charge for the number of DNS requests and the fees are very high (why?)

    Read the article

  • Disabling Keyboard Wakeup for Ubuntu 10.04 on Acer 1810TZ

    - by sybreon
    My Acer Aspire 1810TZ laptop suspends fine but wakes up on any slight key-press. I would like to disable this behaviour. I read that it involves disabling something in the /proc/acpi/wakeup but SLPB does not seem to be listed at all. root@1810TZ:/etc# cat /proc/acpi/wakeup Device S-state Status Sysfs node UHC0 S3 disabled pci:0000:00:1d.0 UHC1 S3 disabled pci:0000:00:1d.1 UHC2 S3 disabled pci:0000:00:1d.2 UHCR S3 disabled EHC1 S3 disabled pci:0000:00:1d.7 UHC3 S3 disabled pci:0000:00:1a.0 UHC4 S3 disabled UHC5 S3 disabled EHC2 S3 disabled pci:0000:00:1a.7 EXP1 S4 disabled pci:0000:00:1c.0 PXSX S4 disabled pci:0000:01:00.0 EXP2 S4 disabled PXSX S4 disabled EXP3 S4 disabled PXSX S4 disabled EXP4 S4 disabled pci:0000:00:1c.3 PXSX S4 disabled pci:0000:02:00.0 EXP5 S4 disabled PXSX S4 disabled EXP6 S4 disabled PXSX S4 disabled However, the relevant bits seem to be detected from dmesg. [ 0.357628] ACPI: AC Adapter [ACAD] (on-line) [ 0.357749] input: Power Button as /devices/LNXSYSTM:00/LNXSYBUS:00/PNP0C0C:00/input/input0 [ 0.357754] ACPI: Power Button [PWRB] [ 0.357817] input: Lid Switch as /devices/LNXSYSTM:00/LNXSYBUS:00/PNP0C0D:00/input/input1 [ 0.359319] ACPI: Lid Switch [LID0] [ 0.359390] input: Sleep Button as /devices/LNXSYSTM:00/LNXSYBUS:00/PNP0C0E:00/input/input2 [ 0.359394] ACPI: Sleep Button [SLPB] [ 0.359475] input: Power Button as /devices/LNXSYSTM:00/LNXPWRBN:00/input/input3 [ 0.359479] ACPI: Power Button [PWRF] Not quite sure what to do next.

    Read the article

  • FastGate A20 Line And Himem.sys Issue With Updating BIOS

    - by Boris_yo
    I have been persistent with a thought to perform my first BIOS update ever through MS-DOS but have been postponing this task until today. Despite people telling me any bootable ISO will do it either through CD-ROM or RAMDRIVE, I am still having problems. First is the problem with CD-ROM driver trying to make it work with 4 driver files (cd1.SYS, cd2.SYS, cd3.SYS, cd4.SYS) as well as starting RAMDISK proved to be failure: CD-ROM XMS Allocation Error RAMDISK XMS Allocaton Error (X: and R: drives not working) This A20 line seemed to be the obstacle which then after a couple of searches pointed me to this article on Microsoft website. It seems that FastGate is the culprit which takes over A20 line and conflicts with himem.sys which should be handling it causing the driver to be unable to allocate memory resources. Albeit article suggests 2 workarounds which is disabling FastGate option or adding switch, I read that the former workaround could cause problems which involves later tinkering BIOS, disabling shadow copy etc. while the latter workaround can just hang system as stated in the link above. I assume it just hangs the boot process from image file though. Summing up the above, I am cautious and think it is risky to follow both workarounds because disabling FastGate or trying adding switch by trying available switches from 1-14 or 16, could crash the BIOS update process by itself. I could do this without the need for himem.sys with bootable USB thumbdrive by making it to be seen as USB-HDD, but some time ago I read that it is never a good idea to update BIOS from hard drive so even thought it is simulation, who knows... Maybe it will deactivate hard drive in the middle of the BIOS update process or even USB thumbdrive per se? One forum discussion was about updating BIOS and somebody suggested to not load himem.sys for some reason, but now that I think of it, what if BIOS update needs upper memory?

    Read the article

  • Setting Up My Home Network

    - by Skizz
    I currently have five PCs at home, three running WinXP and two running Ubuntu. They are set up like this: ISP ----- Modem ---- Switch ---- Ubuntu1 -- B&W Printer | |--WinXP1 | |--WinXP2 Wireless |--Colour Printer | |---------Ubuntu2 |---------WinXP3 (laptop) The Ubuntu1 machine is set up as a PDC using Samba and runs fetchmail, procmail, dovecot to get my e-mail and allow me to access the e-mail via imap so I can read the e-mail on any PC. I'd like to set up the network like this: ISP ----- Modem ---- Ubuntu1 ---- Switch ------WinXP1 | | |--WinXP2 B&W Printer Wireless |--Colour Printer | |---------Ubuntu2 |---------WinXP3 (laptop) My questions are: How to configure Ubuntu1 to act as a firewall. How to configure Ubuntu1 to provide a consistant user authentication across the network, at the moment Samba provides roaming profiles for the XP machines but the Ubuntu2 machine has it's own user lists. I'd like to have a single authentication for both XP machines and linux machines so that users added to the server list will propagate to all PCs (i.e. new users can log on using any PC without modifying any of the client PCs). How to configure a linux client (Ubuntu2 above) to access files on the server (Ubuntu1), some of which are in user specific folders, effectively sharing /home/{user} per user (read and write access) and stuff like /home/media/photos with read access for everyone and limited write access. How to configure the XP machines (if it is different from a the Samba method). How to set up e-mail filtering. I'd like to have a whitelist/blacklist system for incoming e-mails for some of the e-mail accounts (mainly, my kids' accounts) with filtered e-mails being put into quaranteen until a sysadmin either adds the sender to a blacklist or whitelist. OK, that's a lot of stuff. For now, I don't want config files*, rather, what services / applications to use and how they interact. For example, LDAP could be used for authentication but what else would be useful to make the administration of the LDAP easier. Once I have a general idea for the overall configuration, I can ask other questions about the specifics. Skizz I have looked around for information, but most answers are usually in the form of abstract config files and lists of packages to install.

    Read the article

  • Can Current Backflow from Powered Hub's Adapter & cause PC Damage?

    - by SuperUserMan
    Getting this short: Can current flow from a powered USB hub's power adapter (lying 10 Meter away) back to computer via usb port and cause damage to Computer components like mobo, etc? What should be my concerns? Using a 2 Amp 5V Power adapter to power a 10m Long Active Repeater USB extension cable with 4 port HUB & plugging into PC's Front port, causes PC Chassis fan to keep running (thought slower than regular speed) Front Chassis HDD & power LED to turn on (though bit dim) may be other things which i cant detect/see at chip level, in motherboard?? All this even after PC is shut down (bit scary) More detail (in case still want to read): To run 4 High power (needing 450 mAmps) Wifi Adapters, far away from PC, Bought Active Repeater USB Extension Cable with 4 Ports & power port at far end http://www.ebay.com/itm/33FT-USB-2-0-Male-to-Female-Extension-Cable-Hub-Splitter-Adapter-with-4-USB-Port-/390846115254 Then added a locally bought 2 Amp 240V AC to 5V DC Power Adapter and plugged into USB hub which is a part of & situated at far end of a 10 Meter Active Repeater usb extension cable. Even 4 Wifi Adapters run fine (appear to) using this setup, but running chassis fan, dimly lighted Power & HDD LED, even when PC is switched off is bit scary and surely mean 5V & some current is flowing all though that 10 meter extension cable into my USB port & powering stuff. Can this cause damage? and what should be my concerns. Of course I can't switch off the power adapter (lying 10 meters away from PC) every time I switch off my PC to prevent this.

    Read the article

  • How do I repair my Logitech Anywhere MX?

    - by Stefano Palazzo
    My Anywhere Mouse has got mushy mouse button syndrome. That is, the left mouse button feels a little bit soft, and it easily double clicks, let's go when I drag something. Before I repair it at home, rather than bringing it to the store (I kind of need it, it's the only one I have), I'd like to know exactly what I'm doing. It'd be too bad if I tried to repair it, voided the warranty and didn't succeed. I'm guessing there are screws to open it under the rubber pads. And I suppose I can take those off without breaking them, and put them back on without bending them. How is this mouse held together, and what's the safest way to open it? Once I have it open, will I be able to fix the problem? What's causing the mushy mouse button? Here's what I know so far: It might be the switch itself that's broken, in which case I shouldn't open it (I can't get a replacement, voiding the warranty to "have a look" seems pointless) If there are screws underneath the rubber pads, they're only on the 'front', the back two thirds of the mouse are all battery cover: There's nothing I can see under the batteries either. In the mouse I had before this one, there were sort of springy things connecting the actual button with the switch soldered to the board. They were just lying inside of a bit of plastic, and I could swap the left and right ones easily. If repairing it is more difficult, transferring the problem to the right mouse button would be a very good start.

    Read the article

  • Solaris 10 invalid ARP requests from 0.0.0.0? Link up/down every hour or 2

    - by JWD
    The guys at the data center where I'm hosting a server running Solaris 10 are telling me that my server is making a lot of invalid arp requests. This is an example of a portion of what was sent to me from the logs (with Mac addresses and IP addresses changed). [mymacaddress]/0.0.0.0/0000.0000.0000/[myipaddress]/[Datestamp]) It's being logged every hour. I don't see anything in the arp tables (arp -a) or routing tables (netstat -r) and I don't see anything relating to 0.0.0.0 when snoping the arp requests. The only place I see any reference to 0.0.0.0 is if I do netstat -a for the SCTP SCTP: Local Address Remote Address Swind Send-Q Rwind Recv-Q StrsI/O State ------------------------------- ------------------------------- ------ ------ ------ ------ ------- ----------- 0.0.0.0 0.0.0.0 0 0 102400 0 32/32 CLOSED But not really sure what that means. Doesn't seem like I can disable SCTP. There are some tunable SCTP parameters but it's not something I'm familiar with. Do I have to add changes to /etc/system? Looks like sctp_heartbeat_interval might be what I need to change? If it makes any difference, I have a few solaris zones running on this server, each with their own IP address on a virtual interface. eth0:0, eth0:1, etc. Does anyone have any idea what might be causing this and how to stop it? I think the switch I'm connected to doesn't like it and momentarily drops the connection. Is there anyway to at least block those requests using ipfilter or something else? Update: This was happening more frequently but now it seems to be happening roughly every hour or every two hours. It's not consistent. I tried setting setting the link speed and duplex to match the switch port and that seemed to make it stop happening for a few hours but then it started again.

    Read the article

  • EMC VNX iSCSI setup - unsure about SP/port assignment

    - by pauska
    We have a new VNX5300 waiting to get configured, and I need to plan out the network infrastructure before the EMC tech arrives. It has 4x1gbit iSCSI per SP (8 ports in total), and I'd like to get the most out of the performance until we jump over to 10gig iSCSI. From what I can read from the docs - the recommendation is to use only two ports per SP, with 1 active and 1 passive. Why is this? It seems kind of pointless to have quad-port i/o-modules and then recommend to not use more than two of them? Also - I'm a bit unsure about the zoning. The best practices guide state that you should separate each port on each SP from each other on different logical networks. Does this mean that I have to create 4 logical networks to be able to use all 8 ports? It also gives the following example: Does this mean that A0 and B0 should sit on the same physical switch aswell? Won't this make all traffic go on one switch (if both A1 and B1 are passive)? Edit: Another brainpuzzle I don't get it - each host (as in server) should not have more iSCSI bandwidth available than the storage processor. What on earth does this matter? If serverA have 1gbit and serverB have 100mbit, then the resulting bandwith between them is 100mbit. How can this result in some kind of oversubscription? Edit4: Wait, what. Active and passive ports? The VNX runs in a ALUA configuration with asymmetrical active/active.. there shouldn't be any passive ports, only preferred ones..

    Read the article

  • Looking for Remote Control that works with everything (even Windows 7 Media Center)

    - by T Reddy
    Using my Google-Fu, it seems that the most basic of things one gets with any DVR is the remote control. Had I known it would be difficult just to get a consumer IR receiver for Windows 7 I may not have bothered to build an HTPC. But too late, I already have the HTPC ready to go (minus the CETON card...) So I'm moving away from TiVo, I hate paying the monthly fees and my box is ancient. I'm looking for these solutions to my HTCP setup...I want to: Switch audio from HDMI to SPDIF via the remote control (i.e., switch from TV to Receiver) (as a side note, the built-in audio on the mobo has software to do this). Pressing the volume button on the remote will always change the TV's volume (or the Receiver's if possible) and NOT the PC's volume. The remote/receiver works well around 25 feet. Bonus if the IR Receiver can work with my existing TiVo remote (or other remotes laying around the house) I read a review of the Bluetooth TiVo remote...it sounds promising...but I'm not sure if it is great for Windows 7 HTPC?

    Read the article

  • Cisco 3560+ipservices -- IGMP snooping issue with TTL=1

    - by Jander
    I've got a C3560 with Enhanced (IPSERVICES) image, routing multicast between its VLANs with no external multicast router. It's serving a test environment where developers may generate multicast traffic on arbitrary addresses. Everything is working fine except when someone sends out multicast traffic with TTL=1, in which case the multicast packet suppression fails and the traffic is broadcast to all members of the VLAN. It looks to me like because the TTL is 1, the multicast routing subsystem doesn't see the packets, so it doesn't create a mroute table entry. If I send out packets with TTL=2 briefly, then switch to TTL=1 packets, they are filtered correctly until the mroute entry expires. My question: is there some trick to getting the switch to filter the TTL=1 packets, or am I out of luck? Below are the relevant parts of the config, with a representative VLAN interface. I can provide more info as needed. #show run ... ip routing ip multicast-routing distributed no ip igmp snooping report-suppression ! interface Vlan44 ip address 172.23.44.1 255.255.255.0 no ip proxy-arp ip pim passive ... #show ip igmp snooping vlan 44 Global IGMP Snooping configuration: ------------------------------------------- IGMP snooping : Enabled IGMPv3 snooping (minimal) : Enabled Report suppression : Disabled TCN solicit query : Disabled TCN flood query count : 2 Robustness variable : 2 Last member query count : 2 Last member query interval : 1000 Vlan 44: -------- IGMP snooping : Enabled IGMPv2 immediate leave : Disabled Multicast router learning mode : pim-dvmrp CGMP interoperability mode : IGMP_ONLY Robustness variable : 2 Last member query count : 2 Last member query interval : 1000

    Read the article

  • OpenVZ with bridged interfaces and VLAN

    - by Deimosfr
    Hi, I've got a problem with OpenVZ with bridged VLAN. Here is my configuration: +------+ +-------+ +-----------+ +---------+ br0 |VE101 | | | | OpenBSD |----->| Debian |------->| | | WAN |--->| Router | | OpenVZ | +------+ | | | Firewall |----->| br0 br1 | br1 +------+ +-------+ +-----------+ +---------+------->|VE102 | |br0 | | |VLAN br0.110 +------+ v +---------+ |VE103.110| +---------+ I can't make VLAN work on br0 (br0.110) and I would like to understand why. I don't have any switch so no problem with unmanageable switch. I've configured a VLAN interface on OpenBSD in /etc/hostname.vlan110: inet 192.168.110.254 255.255.255.0 NONE vlan 110 vlandev sis1 And it seems to be working fine. I've also adapted my PF configuration to work with VLAN but I don't see any incoming traffic. On my Debian Lenny, here is my interfaces configuration : # The loopback network interface auto lo iface lo inet loopback # br0 auto br0 iface br0 inet static address 192.168.100.1 netmask 255.255.255.0 gateway 192.168.100.254 network 192.168.100.0 broadcast 192.168.100.255 bridge_ports eth0 bridge_fd 9 bridge_hello 2 bridge_maxage 12 bridge_stp off # VLAN 110 auto br0.110 iface br0.110 inet static address 192.168.110.1 netmask 255.255.255.0 network 192.168.110.0 gateway 192.168.110.254 broadcast 192.168.110.255 pre-up vconfig add br0 110 post-down vconfig rem br0.110 It looks OK, but when I start my VE, here is the message: ... Configure veth devices: veth103.0 Adding interface veth103.0 to bridge br0.110 on CT0 for VE103 can't add veth103.0 to bridge br0.110: Operation not supported VE start in progress... So I've got one error here. I've followed this documentation http://wiki.openvz.org/VLAN but it doesn't work. I've certainly missed something but I don't know why. Someone could help me please? Thanks

    Read the article

  • Prevent Windows from resizing all the apps on the desktop when switching monitors

    - by Greg Hewgill
    Short version: When moving my laptop and sleeping between using different monitors, all my open windows are crammed into the upper left corner as if they tried to fit on the laptop internal screen resolution. I plug in and switch to the external monitor before unlocking my session. Is there a way to prevent this automatic resizing? Longer version: I have a laptop that I move between two locations. I have one docking station, and the same kind of monitor configured for 1600x1200, in both locations. The internal laptop screen is awful so I don't use it. Location A: Docking station, monitor connected via DVI. Location B: No docking station, external monitor connected via VGA cable. In this location I have the laptop lid open for keyboard access but I don't use the laptop screen. When moving from Location A to Location B, the laptop wakes up from sleep, displaying the screen on the internal monitor. I switch to the external monitor display (using Fn+F8 on this laptop), and only after that do I unlock my session with my password. However, Windows has crammed all my nicely arranged windows into the upper left corner as if it were trying to fit them all on the laptop internal screen resolution. When moving from Location B to Location A, I have the laptop lid closed when using the docking station so Windows apparently concludes the screen resolution is 1600x1200 and doesn't resize any windows. The laptop is a Dell Latitude running Windows 7 Professional.

    Read the article

  • Vlaning on WNR3500L

    - by ageis23
    When I try connecting to my wireless network it attempts to connect then gives up. There's something strange going on with the mac's. The eternet switch and all the vlan interfaces have a mac 00:FF:FF:FF:FF:FF. config 'switch' 'eth0' option 'vlan0' '2 3 4 8*' option 'vlan1' '0 8' option 'vlan2' '1 8' config 'interface' 'loopback' option 'ifname' 'lo' option 'proto' 'static' option 'ipaddr' '127.0.0.1' option 'netmask' '255.0.0.0' config 'interface' 'lan' option 'type' 'bridge' option 'ifname' 'eth0.1' option 'proto' 'static' option 'netmask' '255.255.255.0' option 'ipaddr' '192.168.2.1' option 'ip6addr' '' option 'gateway' '192.168.1.253' option 'ip6gw' '' option 'dns' '' config 'interface' 'wan' option 'ifname' 'eth0' option 'proto' 'dhcp' option 'ipaddr' '192.168.1.8' option 'ip6addr' '' option 'netmask' '255.255.255.0' option 'gateway' '192.168.1.253' option 'ip6gw' '' option 'dns' '192.168.1.253' config 'interface' 'dmz' option 'ifname' 'eth0.2' option 'proto' 'static' option 'ipaddr' '192.168.0.1' option 'netmask' '255.255.255.0' Any help on this will be greatly appreciated! When I try setting the mac using macaddr it does nothing. It works perfectly fine when I turn the authentication off. I've also discovered that when wpa2 is switched on I don't receive a association reply from ap. thats my hostapd.conf interface=eth1 driver=broadcom bridge=br-lan ssid=O2BB3 wpa=2 wpa_passphrase=prettywoman wpa_key_mgmt=WPA-PSK rsn_pairwise=CCMP Btw that password is only temporary while am testing.

    Read the article

  • How do I keep a bridge enabled on a bonded interface?

    - by jlawer
    I'm working on setting up a pair of CentOS 6.3 servers that will run a couple of KVM vms and have come across a problem setting up a bridge on a bond. I am using Mode 4 (802.3ad) bonding on a pair of stacked Dell Powerconnect 5524 switches connecting to R320 servers. There are 2 links (1 to each switch) that form a Link Aggregation Group (802.3ad / LACP bonding). On top of the bond I have VLAN Tagging. I've verified this is a problem on multiple other bonding modes so it isn't just a mode 4 issue. I am testing what happens when 1 link is dropped (ie switch dies, cable breaks, etc). If I don't have a bridge (for KVM), everything works fine, failover happens as expected. If I have the bridge enabled, it works fine until failover (unplugging a cable). When failover happens /var/log/messages shows the slave link going down, followed within a second by: kernel: br1: port 1(bond0.8) entering disabled state The thing is /proc/net/bonding/bond0 shows the link is up as expected (simply with only 1 slave instead of 2). If I plug the cable back in it recovers and brings the bridge back to an enabled state. I actually have tested this while a ping is occuring and if the timing is right a packet will actually leave the system after the link is lost, but before the disabled message occurs. This disabled state I assumed was STP, but I have disabled STP on the bridge configuration and this issue still occurs. brctl showstp br1 still shows the link as disabled when it is running without a slave. I also switched between the nics in the server (I have 2x Broadcom & 4x intel). It doesn't matter which configuration I have. Does anyone know of a way to force the bridge to stay enabled or why its detecting the bond as disabled, when it isn't?

    Read the article

  • how to set up dual wireless routers (G and N) with single broadband connection

    - by user15973
    A local cafe has an 802.11g wireless router attached to either an 8- or 12Mbs broadband connection. Although many customers still have -g devices, an increasing number are showing up with 802.11n devices (e.g. Mac laptops, iPads). The cafe owner is content with his router's area coverage, but he would like for his customers to be able to take advantage of the higher -n download speeds. He could simply replace the -g router with a -n router, but reportedly -n routers slow down considerably when servicing both -g and -n connections. Another option would be to buy the -n router, run an Ethernet cable between the two routers, and (of course) hook up the broadband connection to one of the two routers. Still another option would be to attach an ordinary, wired switch to the broadband connection and then attach both routers to the switch. Aside from the cost issue, what are the tradeoffs of those approaches? Which would you recommend, and why? Is there a better option than the ones I mentioned? Thank you in advance for your advice.

    Read the article

  • Why is dwm.exe using so much memory?

    - by Leonard Challis
    I've scoured the web, but I'm sick of reading "scan your computer for viruses" and "upgrade your RAM" on answers to similar questions to this. I understand that dwm.exe is for (simply put) caching bitmaps for things like Aero-peek and similar, but as far as I have read it shouldn't be using vast amounts of memory. My colleague and I both have 4GB of RAM, Core 2 Duo, blah, blah -- essentially they're pretty capable. His dwm.exe is running at around 30mb, mind is currently running at about half a gig, though it does fluctuate quite a lot. This is the same while running the exact same applications (currently Zend studio, FireFox (with firemin - low memory usage), Outlook). Every so often I will get a notification asking me if I want to switch to Aero Basic because it's using too much memory, and sometimes it will just switch itself to basic and let me know why. I know it's possible to stop it switching, but I want to know why it is using too much memory otherwise it's just papering over the cracks. One thing to add is this seems to have started after a robbery on Monday, where two of my monitors were stolen, and I had to temporarily use a couple of alternative monitors. I am now using brand new monitors but the problem is the same. All drivers installed and working seemingly fine. Any ideas why the usage is so high? We are using windows 7 64-bit Professional.

    Read the article

  • High speed network configuration

    - by Peter M
    Sorry if this seems to be a stupid question, I'm not sure how to specify what I want to know when checking google. I will have 2 or 3 devices pumping out data on a 100Base-T port. The combined data rate of all devices is about 15KB/S which exceeds the optimal 100Base-T channel capacity (12KB/S), but well within the realms of a 1000Base-T connection. Each device will be sending a burst of data in the form of an FTP transfer to a common, single host computer in a sequential manner ie: Device A establishes FTP connection and transfers data Device B establishes FTP connection and transfers data Device C establishes FTP connection and transfers data It may be that the A&B, B&C and C&A transfers overlap in the time domain to some extent. There will be minimal traffic going back from the computer to each device (in general what ever is needed to support the FTP transfers), and the network will be dedicated to transferring data between these devices and the host computer. Is it possible to use a switch to combine the multiple incoming 100Base-T streams into a single outgoing 1000Base-T stream? if so what features in a switch should I be looking for? Or would it be better to have 3 physical point-to-point 100Base-T dedicated connections between each device and the host computer? (thus having at least 3 physical Ethernet interfaces on that computer) Note that I can't change the interface on the devices, but I am free to choose the network and host computer configuration. Thanks for you help Peter

    Read the article

  • Intermittently uncommunicative subnets

    - by mhd
    Last week proved me a veritable Cassandra: I've always said that it's a bad idea to have only one firewall/router, without a backup or failover. And thus our Cisco PIX went haywire, refusing to route properly. And of course, the only one available here on short notice is me, and while I'm quite grounded in Linux, I'm really a developer not a sysadmin (the fact that this hit me on sysadmin appreciation day is a bit ironic). Anyway, this weekend I tried to hack up a temporary solution: I used an old server with enough NICs (two built-in, four on a card) to serve as a gateway and firewall. Due to some problems with the raid controller, I got only two router distros running, and between Untangle and Ebox I decided for the latter. Now everything is quite okay. I've got all the different subnets we've got here (all with separate switches) talking to each other and even to the internet (Cisco 2800 router, T1 lines). But from time to time (20-60 minute intervals), I get a total routing failure. Our main, office subnet can't talk to our server subnet and can't connect to the internet. This is not the end of a gradual slowdown, either everything's working perfectly or I get a total lack of communication for about two minutes each time. Now I'm a bit at wits end what to check. At least with the default EBox setup, nothing in /var/log shows anything weird and it doesn't exactly have lots of built-in monitoring tools. So I'm hoping someone here could give me some pointers about what to look out for. I did change the ethernet cable from the office switch to the firewall, with no results. I might change switches, although within the switch it seems to work ok enough. Edit: I'm not sure whether this is the sole cause of the problem, but after I noticed a few DHCP entries just before the last drop of connectivity, I tried to reproduce that. And alas, whenever I renew a DHCP connection, I can't access other subnets anymore. Running ISC DHCPD 3.0.6.

    Read the article

  • Problem with Strange VMWare behaviour when shutting down guest.

    - by adza77
    Hi, I've been having a problem for a while now with VMWare Workstaion. (Originally with 6.5, but now with 7.0 and 7.0.1 too). The problem occurs when I choose to shut down a guest. VMWare itself seems to hang. If I choose to shut down a guest that's opened full screen, and during the process I minimise the screen to work on other applications in the host, often (not all the time) when I return to the guest I have a 'greyed out' screen and the system becomes unresponsive. The host O/S still seems to be working, but I am unable to switch to other applications. (I can bring up the taskbar on the host and 'see' other applications and even switch to them, but VMWare still stays 'on top' being unresponsive). I can not terminate VMWare even when windows says that the application has become unresponsive and gives me the option to terminate. VMWare stays on top, and I'm forced to either shutdown, or log off and log back on in order to regain control of my computer. This happens with both Windows 7 and Windows Vista guest operating systems (32 bit), and I have had it happen on multiple host machines, and multiple guest machines too. Current Host: Windows 7 64 bit, 8GB Ram, 500GB HDD, i7 Processor. I have been searching for more than 6 months for a solution but have found none, so finally decided to post here. Does anyone know what might be causing the problem (+or even how to minimize the VM so I can at least access any other applications and save work before forcing a logoff / reboot+) would be extrememly handly. If I know the correct keystrokes to save and close in an application on the host I can do this by task-switching to the desired app to save and close successfully, but I can't see what I'm doing because VMWare Workstation is still on-top 'greyed' out. Cheers Adam.

    Read the article

  • Problem with Strange VMWare behaviour when shutting down guest.

    - by adza77
    Hi, I've been having a problem for a while now with VMWare Workstaion. (Originally with 6.5, but now with 7.0 and 7.0.1 too). The problem occurs when I choose to shut down a guest. VMWare itself seems to hang. If I choose to shut down a guest that's opened full screen, and during the process I minimise the screen to work on other applications in the host, often (not all the time) when I return to the guest I have a 'greyed out' screen and the system becomes unresponsive. The host O/S still seems to be working, but I am unable to switch to other applications. (I can bring up the taskbar on the host and 'see' other applications and even switch to them, but VMWare still stays 'on top' being unresponsive). I can not terminate VMWare even when windows says that the application has become unresponsive and gives me the option to terminate. VMWare stays on top, and I'm forced to either shutdown, or log off and log back on in order to regain control of my computer. This happens with both Windows 7 and Windows Vista guest operating systems (32 bit), and I have had it happen on multiple host machines, and multiple guest machines too. Current Host: Windows 7 64 bit, 8GB Ram, 500GB HDD, i7 Processor. I have been searching for more than 6 months for a solution but have found none, so finally decided to post here. Does anyone know what might be causing the problem (+or even how to minimize the VM so I can at least access any other applications and save work before forcing a logoff / reboot+) would be extrememly handly. If I know the correct keystrokes to save and close in an application on the host I can do this by task-switching to the desired app to save and close successfully, but I can't see what I'm doing because VMWare Workstation is still on-top 'greyed' out. Cheers Adam.

    Read the article

< Previous Page | 80 81 82 83 84 85 86 87 88 89 90 91  | Next Page >